@@ -0,0 +1,159 @@
|
||||
## WARNING ##
|
||||
|
||||
MIB-based polling is experimental. It might overload your LibreNMS server,
|
||||
destroy your data, set your routers on fire, and kick your cat. It has been
|
||||
tested against a very limited set of devices (namely Ruckus ZD1000 wireless
|
||||
controllers, and `net-snmp` on Linux). It may fail badly on other hardware.
|
||||
|
||||
The approach taken is fairly simplistic and I claim no special expertise in
|
||||
understanding MIBs. Most of my knowledge of SNMP comes from reading net-snmp
|
||||
man pages, and reverse engineering the output of snmptranslate and snmpwalk
|
||||
and trying to make devices work with LibreNMS. I may have made false
|
||||
assumptions and probably use wrong terminology in many places. Feel free to
|
||||
offer corrections/suggestions via pull requests or email.
|
||||
|
||||
Paul Gear <paul@librenms.org>
|
||||
|
||||
## Overview ##
|
||||
|
||||
This is the 2nd experimental release of MIB polling. If you used the 1st
|
||||
release, you MUST perform a data conversion of the MIB-based polling files
|
||||
using the script `contrib/convert-mib-graphs.sh`. Failure to do so will
|
||||
result in your data collection silently stopping.
|
||||
|
||||
MIB-based polling is disabled by default; you must set
|
||||
`$config['poller_modules']['mib'] = 1;`
|
||||
in `config.php` to enable it.
|
||||
|
||||
## Preparation ##
|
||||
|
||||
MIB-based polling results in the creation of a separate RRD file for each
|
||||
device-MIB-OID-index combination encountered by LibreNMS. Thus it can cause
|
||||
your disk space requirements to grow enormously and rapidly. As an example,
|
||||
enabling MIB-based polling on my test Ruckus ZD1000 wireless controller with
|
||||
one (1) AP and one (1) user on that AP resulted in a 5 MB increase in RRD
|
||||
space usage for that device. Each RRD file is around 125 KB in size (on
|
||||
x64-64 systems) and is pre-allocated, so after the first discovery and poller
|
||||
run of each devicewith MIB-based polling enabled, disk space should be stable.
|
||||
However, monitoring disk usage is your responsibility. (The good news: you
|
||||
can do this with LibreNMS. :-)
|
||||
|
||||
Unless you are running LibreNMS on a powerful system with pure SSD for RRD
|
||||
storage, it is strongly recommended that you enable rrdcached and ensure it is
|
||||
working *before* enabling MIB-based polling.
|
||||
|
||||
## Components ##
|
||||
|
||||
The components involved in MIB-based polling are:
|
||||
|
||||
### Discovery ###
|
||||
|
||||
- OS discovery determines whether there are MIBs which should be polled. If
|
||||
so, they are registered in the `device_mibs` association table as relevant
|
||||
to that device. MIB associations for each device can be viewed at:
|
||||
http://your.librenms.server/device/device=XXXX/tab=mib/
|
||||
All MIBs used by MIB-based polling may be viewed at:
|
||||
http://your.librenms.server/mibs/
|
||||
All device associations created by MIB-based polling may be viewed at:
|
||||
http://your.librenms.server/mib_assoc/ (Devices -> MIB associations)
|
||||
|
||||
- In addition, all devices are checked for a MIB matching their sysObjectID.
|
||||
If there is a matching MIB available, it is automatically included.
|
||||
The sysObjectID for each device is now displayed on the overview page:
|
||||
http://your.librenms.server/device/device=XXXX/
|
||||
|
||||
- Note that the above means that no MIB-based polling will occur until the
|
||||
devices in question are rediscovered. If you want to begin MIB-based
|
||||
polling immediately, you must force rediscovery from the web UI, or run it
|
||||
from the CLI using `./discovery.php -h HOSTNAME`
|
||||
|
||||
- During discovery, relevant MIBs are parsed using `snmptranslate`, and the
|
||||
data returned is used to populate a database which guides the poller in
|
||||
what to store. At the moment, only OIDs with Unsigned32 and Counter64
|
||||
data types are parsed.
|
||||
|
||||
- Devices may be excluded from MIB polling by changing the setting in the
|
||||
device edit screen:
|
||||
http://your.librenms.server/device/device=XXXX/tab=edit/section=modules/
|
||||
|
||||
### Polling ###
|
||||
|
||||
- During polling the MIB associations for the device are looked up, and the
|
||||
MIB is polled for current values. You can see the values which LibreNMS
|
||||
has retrieved from the MIB poller in the "Device MIB values" section of
|
||||
http://your.librenms.server/device/device=XXXX/tab=mib/
|
||||
|
||||
- Data from the latest poll is saved in the table `device_oids`, and RRD
|
||||
files are saved in the relevant device directory as
|
||||
mibName-oidName-index.rrd
|
||||
|
||||
### Graphing ###
|
||||
|
||||
- For each graph type defined in the database, a graph will appear in:
|
||||
http://your.librenms.server/device/device=XXXX/tab=graphs/group=mib/
|
||||
- MIB graphs are generated generically by
|
||||
`html/includes/graphs/device/mib.inc.php`
|
||||
There is presently no customisation of graphs available.
|
||||
- If there is only one index under a given OID, it is displayed as a normal
|
||||
line graph; if there multiple OIDs, they are displayed as a stacked graph.
|
||||
At the moment, all indices are placed in the same graph. This is
|
||||
non-optimal for, e.g., wifi controllers with hundreds of APs attached.
|
||||
|
||||
### Alerting ###
|
||||
|
||||
There is no specific support for alerting in the MIB-based polling engine, but
|
||||
the data it collects may be used in alerts. Here's an example of an alert
|
||||
which detects when a Ruckus wireless controller reports meshing disabled on an
|
||||
access point:
|
||||
http://libertysys.com.au/imagebin/3btw98DR.png
|
||||
|
||||
|
||||
## Adding/testing other device types ##
|
||||
|
||||
One of the goals of this work is to help take out the heavy lifting of adding
|
||||
new device types. Even if you want fully-customised graphs or tables, you can
|
||||
still use the MIB-based poller to make it easy to gather the data you want to
|
||||
graph.
|
||||
|
||||
### How to add a new device MIB ###
|
||||
|
||||
1. Ensure the manufacturer's MIB is present in the mibs directory. If you
|
||||
plan to submit your work to LibreNMS, make sure you attribute the source
|
||||
of the MIB, including the exact download URL if possible, or explicit
|
||||
instructions about how to obtain it.
|
||||
2. Check that `snmptranslate -Ts -M mibs -m MODULE | grep mibName` produces
|
||||
a named list of OIDs. See the comments on `snmp_mib_walk()` in
|
||||
`includes/snmp.inc.php` for an example.
|
||||
3. Check that `snmptranslate -Td -On -M mibs -m MODULE MODULE::mibName`
|
||||
produces a parsed description of the OID values. An example can be
|
||||
found in the comments for `snmp_mib_parse()` in `includes/snmp.inc.php`.
|
||||
4. Get the `sysObjectID` from a device, for example:
|
||||
```snmpget -v2c -c public -OUsb -m SNMPv2-MIB -M /opt/librenms/mibs -t 30 hostname sysObjectID.0```
|
||||
5. Ensure `snmptranslate -m all -M /opt/librenms/mibs OID 2>/dev/null`
|
||||
(where OID is the value returned for sysObjectID above) results in a
|
||||
valid name for the MIB. See the comments for `snmp_translate()` in
|
||||
`includes/snmp.inc.php` for an example. If this step fails, it means
|
||||
there is something wrong with the MIB and `net-snmp` cannot parse it.
|
||||
6. Add any additional MIBs you wish to poll for specific device types to
|
||||
`includes/discovery/os/OSNAME.inc.php` by calling `poll_mibs()` with the
|
||||
MIB module and name. See `includes/discovery/os/ruckuswireless.inc.php`
|
||||
for an example.
|
||||
7. That should be all you need to see MIB graphs!
|
||||
8. If you want to develop more customised support for a particular OS, you
|
||||
can follow the above process, then use the resultant data collected by
|
||||
LibreNMS in the RRD files or the database tables `device_oids`
|
||||
|
||||
|
||||
## TODO ##
|
||||
|
||||
What's not included in MIB-based polling at present? These may be present in
|
||||
future versions. Pull requests gratefully accepted!
|
||||
|
||||
- Parse and save integer and timetick data types.
|
||||
- Filter MIBs/OIDs from being polled and/or saved.
|
||||
- Move graphs from the MIB section to elsewhere. e.g. If a device uses a
|
||||
unique MIB for CPU utilisation, we should display it under the relevant
|
||||
health tab.
|
||||
- Combine multiple MIB values into graphs automatically on a predefined or
|
||||
user-defined basis.
|
||||
- Include MIB types in stats submissions.
|
||||
Reference in New Issue