* On my device (AP7901 / AOS v3.9.0 / App v3.7.4) discovery would keep clobbering the bank and current sensor. Looking in to it the oid should be used for current and not bank. To fix this now it pulls a count of banks using the `rPDULoadDevNumBanks.0` oid. Per MIB that will return 0 if no banks are found. In which case skip the bank detection. * Also update PowerNet-MIB to v4.1.7 released 2015-08-05
72041 lines
2.2 MiB
Plaintext
72041 lines
2.2 MiB
Plaintext
-- *************************************************************************
|
|
-- AMERICAN POWER CONVERSION PowerNet-MIB
|
|
-- *************************************************************************
|
|
-- Copyright (c) 2016 American Power Conversion, Inc.
|
|
-- PowerNet is a Trademark of American Power Conversion Corp.
|
|
--
|
|
-- Title: APC TOP LEVEL PowerNet MIB
|
|
--
|
|
-- Version : 4.1.7
|
|
--
|
|
-- Generated by script: tomib.awk
|
|
--
|
|
-- Input File: powernetPS.mib
|
|
--
|
|
-- Created: Wednesday, January, 06, 2016
|
|
--
|
|
-- Revision History:
|
|
-- *************************************************************************
|
|
|
|
-- - v3.2.0 Added functionality for MasterSwitch Plus
|
|
-- - v3.3.0 Added functionality for MX28B (dcDM3) and 3-phase UPS
|
|
-- - v3.3.2 New traps for Symmetra PX UPS
|
|
-- 07/15/01 - v3.4.0 Added transfer switch
|
|
-- - v3.4.3 Added functionality for External and Integrated Environmental Monitor
|
|
-- 06/14/02 - v3.4.4 Added dcmim2(Siemens) branch, Battery Manager(Reading) traps, and
|
|
-- Psx Traps for PDU and RM-PDU and Netlock branch/traps
|
|
-- 12/13/02 - v3.5.0 netlock - Initial support for netlock (nl). Traps 261-265 added.
|
|
-- rPDU - Initial support for rPDU. Traps 266-283 added.
|
|
-- rARU - Initial support for rARU.
|
|
-- gateway - Initial support for gateway (gw). Traps 230-260, 284-297 added.
|
|
-- ups - upsSyncCtrlGroup and upsState sections added.
|
|
-- 02/19/03 - v3.6.0 ups - UpsOutletGroups section added. Traps 298-299 added.
|
|
-- smw - Traps 300-305 added.
|
|
-- rPDU - General OID description cleanups.
|
|
-- gw - Updated SNMP support for gw.
|
|
-- 05/21/03 - v3.6.1 ups - Updated SNMP support for ups.
|
|
-- ems - Environmental Management System OIDs renamed from gateway (gw).
|
|
-- raru - Updated SNMP support for raru.
|
|
-- 06/13/03 - v3.6.3 airFM - Initial support for airFM. Traps 306-311 added.
|
|
-- nl - Traps 261-265 removed.
|
|
-- 11/26/03 - v3.6.4 xPDU - Initial support for xPDU. Traps 312-344 added.
|
|
-- airPA - Initial support for airPA. Traps 306-311 modified for airPA use.
|
|
-- airFM - AirFMStatus OIDs cleaned up.
|
|
-- 03/19/04 - v3.6.5 rPDU - Updated SNMP support for rPDU.
|
|
-- airFM - AirFMGroup section added.
|
|
-- 05/13/04 - v3.6.6 ups - Added several upsAdvBattery OIDs.
|
|
-- ems - Added emsStatusHardwareStatus and emsHardwareState traps 345-346.
|
|
-- aru - Trap 228 redefined to aruDeviceConfigChange.
|
|
-- 08/04/04 - v3.6.7 ups - Added upsAdvConfigNumExternalBatteries and
|
|
-- upsAdvConfigSimpleSignalShutdowns.
|
|
-- ce - Custom Event traps 347-352 added.
|
|
-- 11/22/04 - v3.6.8 ems - Many emsProbeConfig and emsProbeStatus OIDs added.
|
|
-- ups - Traps 353-358 added.
|
|
-- env - Traps 359-374 added.
|
|
-- 01/26/05 - v3.6.9 battman - Initial support for battman, traps 375-380 added.
|
|
-- xATS - Initial support for xATS, traps 381-478 added.
|
|
-- generator - Initial support for generator.
|
|
-- rPDU - Trap edits.
|
|
-- xPDU - Trap edits.
|
|
-- 05/26/05 - v3.7.0 consolePortServer - Initial support for consolePortServer (cpsAP930x).
|
|
-- xPDU - Cleaned up many descriptions.
|
|
-- xATS - Cleaned up many descriptions.
|
|
-- ups - Added several upsAdvConfig OIDs.
|
|
-- 09/28/05 - v3.8.0 modEnvMgr - Initial support for modEnvMgr (mem).
|
|
-- rARU - Added functionality for Gen 2 ARU.
|
|
-- ups/aru/mem - Traps 500-569 added.
|
|
-- all - General cleanup on typos and spelling errors.
|
|
-- 01/04/06 - v3.8.1 rARU - Added functionality for Gen 2 ARU
|
|
-- 02/22/06 - v3.8.2 accessControl - Initial support for accessControl.
|
|
-- Traps 570-592 added.
|
|
-- accessPX - Initial support for accessPX.
|
|
-- airIR - Initial support for airIR and airIRAlarms.
|
|
-- airIRRC - Initial support for airIRRC.
|
|
-- 05/24/06 - v3.8.4 apcLocalDisplay - Initial support for apcLocalDisplay.
|
|
-- ups - UpsAdvOutputRedundancy, upsAdvOutputKVACapacity,
|
|
-- upsAdvConfigBasicSignalLowBatteryDuration, and
|
|
-- upsAdvConfigBypassPhaseLockRequired OIDs added.
|
|
-- UpsAdvConfigMinReturnRuntime SYNTAX changed.
|
|
-- UPS trap numbers 600-623 added.
|
|
-- em - New emConfigProbe, emConfigContact, emStatusProbe OIDs added.
|
|
-- iem - New iemConfigProbe, iemConfigContact, iemStatusProbe OIDs added.
|
|
-- 08/31/06 - v3.8.5 airIRSC - Initial support for airIRSC.
|
|
-- XPDU - XPDUBranchBreaker OIDs and xPDUBranchCurrent traps added.
|
|
-- 11/03/06 - v3.8.6 rPDU - Updated SNMP support for rPDU.
|
|
-- accessPX - accessPXConfigCardFormat OID added.
|
|
-- airIRSC - airIRSCUnitStatusCompressor added.
|
|
-- 01/03/07 - v3.8.7 airIRRP - Initial support for airIRRP100 and airIRRP500.
|
|
-- 04/06/07 - v3.8.8 battMan - Updated SNMP support for Battery Manager,
|
|
-- battManConfigApplication OID deprecated.
|
|
-- airIRRP - Added HeatAssistEnable to airIRRP100 and airIRRP500.
|
|
-- ups - Added several upsDiagSubSys OIDs.
|
|
-- iem - Added iemStatusProbeLocation OID.
|
|
-- all - Cleaned up version history section.
|
|
-- 12/19/07 - v3.9.1 airFM - Added full SNMP support, deprecating some existing OIDs in
|
|
-- favor of new structure.
|
|
-- 12/19/07 - v3.9.2 Added new OIDs for isxModularDistribution, isxModularPdu, airInRoomPerimeter
|
|
-- airIRGen2, symmetraPX IDs, isxServers IDs, upsAdvConfig, upsDiagSubSysNetworkComCard,
|
|
-- memInputsCommStatus, airIRRP100GroupSetpoints. Added new SNMP Traps for
|
|
-- ISX Modular Distribution, and xATS.
|
|
-- 08/13/08 - v3.9.3 Added new OIDs for UPS HighPrec OIDs:
|
|
-- upsHighPrecBattery, upsHighPrecInput, and upsHighPrecOutput.
|
|
-- Added new OIDs for the 10kW the AIR IR Gen2:
|
|
-- airIRG2RDT2ConfigUnitRoleOverride, airIRG2RDT2RunHoursUnit,
|
|
-- airIRG2GroupConfigNumberofBackupUnits, airIRG2GroupConfigRuntimeBalancingEnable,
|
|
-- and airIRG2GroupConfigLoadAssistEnable for use by 10kW application.
|
|
-- Added new traps apcInternalCommunicationFault and apcInternalCommunicationFaultCleared
|
|
-- for use by the SUMX application.
|
|
-- Updated descriptions in existing OIDs.
|
|
-- 09/25/08 - v3.9.4 Added new OIDs for Symmetra PX:
|
|
-- upsParallelSystem, upsPhysicalLayout, upsAdvConfigMainsSetting, upsAdvConfigACWiringSetting,
|
|
-- upsAdvConfigUpperOutputVoltTolerance, upsAdvConfigLowerOutputVoltTolerance, upsAdvConfigUpperBypassVoltTolerance
|
|
-- upsAdvConfigLowerBypassVoltTolerance, upsAdvConfigOutofSyncBypassTransferDelay, upsAdvTestDiagnosticTime
|
|
-- upsAdvTestDiagnosticDay, upsDiagSwitchGearBypassInputSwitchStatus, upsDiagSubFeedBreakerTable,
|
|
-- upsDiagSubFeedBreakerTable, upsSideCarFrameLayoutTable, upsPowerFrameLayoutTable
|
|
-- Added new OIDs for UPSs:
|
|
-- upsBasicSystemStatus, upsAdvControlFlashAndBeep (appended new list options)
|
|
-- Added new OIDs for the AC RP10kW:
|
|
-- airIRG2RDT2ConfigUnitIdleOnCoolFail
|
|
-- Added new OID for isxModularPDU device:
|
|
-- isxModularPduDeviceTransformerPresent (appended new list option)
|
|
-- 02/24/09 - v3.9.5 Added new OIDs for the UPS Integrated ATS product, Air IRSC product, added new Traps for UPS support
|
|
-- and fixed MIB compilier warnings.
|
|
-- 02/24/09 - v3.9.6 Added new Traps and mtrapargs for the ISXC Trap Notification support.
|
|
-- 09/18/09 - v3.9.8 Added new OIDs for the InRoom C7000 Air product.
|
|
-- 04/14/10 - v3.9.9 Added new rPDU2 device and modified some rPDU OIDs.
|
|
-- 06/22/10 - v4.0.0 Added traps 638 through 651 to support ATS.
|
|
-- Updated control OIDs for rPDU2g
|
|
-- Updates to support PX100kW UPS.
|
|
-- Added traps 756 and 757 to support PX100kW UPS.
|
|
-- Added upsAdvBattery, upsHighPrecBattery, and upsDiagBattery OIDs to support PX250kW/PX500kW UPS.
|
|
-- 06/30/10 - v4.0.1 Added new OID's upsAdvBatteryFullCapacity, upsAdvInputNominalFrequency, upsAdvInputNominalVoltage,
|
|
-- upsAdvInputBypassNominalFrequency, upsAdvInputBypassNominalVoltage, upsBasicSystemInternalTemperature,
|
|
-- upsAdvOutputNominalFrequency, upsAdvOutputActivePower and upsAdvOutputApparentPower.
|
|
-- Added traps 734 to 739 to support Galaxy 300 and Galaxy 7000 UPS.
|
|
-- Added SyOid's galaxy300UPS10kVA33, galaxy300UPS15kVA33, galaxy300UPS20kVA33,
|
|
-- galaxy300UPS30kVA33, galaxy300UPS40kVA33, galaxy300UPS10kVA31, galaxy300UPS15kVA31,
|
|
-- galaxy300UPS20kVA31 and galaxy300UPS30kVA31,galaxy7000UPS200kVA,galaxy7000UPS250kVA,
|
|
-- galaxy7000UPS300kVA,galaxy7000UPS400kVA,galaxy7000UPS500kVA,galaxy7000SSC800kVA,
|
|
-- galaxy7000SSC1200kVA and galaxy7000SSC2000kVA.
|
|
-- 10/27/10 - v4.0.2 Added Idle on Cool Fail and Fan Speed Control OIDs for the InRow ACRC.
|
|
-- Added new OID's for Odin UPS upsAdvInputStatisticsTable, upsAdvInputApparentPower,
|
|
-- upsAdvInputVoltageTHD, upsAdvInputBypassVoltageTHD, upsAdvInputPeakCurrent, upsAdvInputBypassPeakCurrent,
|
|
-- upsAdvOutputStatisticsTable, upsAdvOutputPeakCurrent, upsAdvOutputCurrentTHD, upsAdvOutputCrestFactor,
|
|
-- upsAdvStateTotaltimeonbattery, upsAdvStateTotaltimeonbypass, upsAdvStateTotaltimeonNormal,
|
|
-- upsAdvStateNumberoftimesonbattery, upsAdvStateNumberoftimesbypass, upsAdvStateNumberoftimesNormal,
|
|
-- subfeedBreakerUpperAcceptPowerCritical, upsParallelInputMaximumCurrent, upsParallelTotalOutputPower,
|
|
-- upsParallelTotalOutputApparentPower, upsParallelInputCurrent, upsParallelInputActivePower,
|
|
-- upsParallelInputApparentPower, upsParallelInputVoltage, upsParallelInputMaxVoltage,
|
|
-- upsParallelInputMaxCurrent, upsParallelInputTotalActivePower, upsParallelInputTotalApparentPower,
|
|
-- upsParallelOutputCurrent, upsParallelOutputLoad, upsParallelOutputPercentLoad, upsParallelOutputPower,
|
|
-- upsParallelOutputApparentPower, upsParallelDiagSubSysBreakerStatus, upsParallelDiagSubSysBreakerName
|
|
-- and upsParallelOutputTotalPercentLoad.
|
|
-- Modified the OID upsAdvConfigOutputFreqRange and upsParallelSysRedundancy.
|
|
-- 01/13/11 - v4.0.3 Added new oids, upsHighPrecOutputEfficiency and upsHighPrecOutputEnergyUsage.
|
|
-- Added green mode for bit 51 of upsBasicStateOutputState.
|
|
-- Added traps 758 to 763 to support UPS firmware update.
|
|
-- Deprecated all OIDs off branch mfiletransfer
|
|
-- Added rPDU2 Metered Outlet Data
|
|
-- 08/17/11 - v4.0.4 Updated several rPDU2 and rPDU OIDs.
|
|
-- 12/07/11 - v4.0.5 Added new OID's for SYPX upsPhaseOutputPowerFactor and symmetraPxDisplay.
|
|
-- Added SYS OID's for different Caphorn models galaxy5000UPS20KVA, galaxy5000UPS30KVA, galaxy5000UPS40KVA
|
|
-- galaxy5000UPS50KVA, galaxy5000UPS60KVA , galaxy5000UPS80KVA, galaxy5000UPS100KVA, galaxy5000UPS120KVA
|
|
-- galaxy5000UPS130KVA, galaxy5500UPS20KVA, galaxy5500UPS30KVA, galaxy5500UPS40KVA, galaxy5500UPS50KVA
|
|
-- galaxy5500UPS60KVA, galaxy5500UPS80KVA, galaxy5500UPS100KVA, galaxy5500UPS120KVA, galaxy5500UPS130KVA
|
|
-- and new OID upsAdvStateEcomode
|
|
-- 06/05/12 - v4.0.6 Added new OID rPDUIdentDeviceLineToNeutralVoltage for AP7823 Rack PDU.
|
|
-- 06/20/12 - v4.0.6 Added new rPDU2Group OID table for AP84xx, AP86xx, AP88xx, AP89xx Rack PDUs.
|
|
-- 08/10/12 - v4.0.6 Added new OIDs for SYPX 250/500 upsAdvConfigWarningAlarmDelay, upsAdvConfigInformationalAlarmDelay, upsDiagSwitchGearInstallationLoadPct,
|
|
-- upsParallelOutputActivePowerTable,upsParallelSysSwitchGearInstallationLoadPct, upsParallelSysRedundancyStatus and upsParallelSysName.
|
|
-- Modified the description for upsBasicBatteryLastReplaceDate and bit 51 of upsBasicStateOutputState.
|
|
-- Updated upsBasicOutputStatus and upsBasicSystemStatus.
|
|
-- 08/10/12 - v4.0.6 Added SYS OIDs for different Caphorn models galaxy9000UPS, galaxy9000SSC, galaxy9000UPSWithSSC, galaxy9000FreqConverter, eps6000UPS,
|
|
-- eps6000SSC, eps6000UPSWithSSC, eps6000FreqConverter, eps7000UPS, eps7000SSC, eps7000UPSWithSSC,
|
|
-- eps7000FreqConverter, eps8000UPS, eps8000SSC, eps8000UPSWithSSC, eps8000FreqConverter.
|
|
-- Modified the description for bits 53 to 56 of upsBasicStateOutputState.
|
|
-- 02/22/13 -v4.0.8 Added OIDs upsAdvBatteryInternalSKU, upsAdvBatteryExternalSKU, upsAdvBatteryRecommendedReplaceDate,
|
|
-- upsAdvConfigGreenMode, upsAdvConfigLCDLocalLanguage, upsAdvConfigLCDLockOut,
|
|
-- upsAdvConfigChargerRate, and upsAdvConfigBatterySelection for the SUMX application.
|
|
-- 04/10/13 -v4.0.9 Added new SYS OID for sPDU masterSwitchsPDU
|
|
-- 10/18/13 -v4.1.0 Added new cooling section of OIDs for second generation cooling products.
|
|
-- 02/17/14 -v4.1.1 Added the OIDs for Valhal(Galaxy VM)UPS.
|
|
-- 08/11/14 -v4.1.2 Added upsHighPrecBatteryPacks category.
|
|
-- Added upsHighPrecInputBypassVoltage and upsHighPrecInputBypassFrequency OIDs.
|
|
-- Added traps upsLocalDisplayButtonFault, upsLocalDisplayButtonFaultCleared, upsNeedsFactorySetupFault,
|
|
-- upsNeedsFactorySetupFaultCleared, upsEPOActive, upsEPOActiveCleared, upsFirmwareMismatch, upsFirmwareMismatchCleared,
|
|
-- upsOscillatorFailed, and upsOscillatorFailedCleared
|
|
-- Updated the description for upsHighPrecOutputEfficiency to display all currently defined error conditions.
|
|
-- 11/25/14 -v4.1.4 Changes for IRRP100 and IRRP500:
|
|
-- 1.New OIDs added to support Active Flow Controller:
|
|
-- airIRRP100GroupStatusActiveFlowControlStatus, airIRRP100GroupSetpointsActiveFlowControlBias, airIRRP100GroupConfigNumberOfActiveFlowControllers,
|
|
-- airIRRP100GroupConfigActiveFlowControllerLampTest, airIRRP100GroupConfigAltitudeUS, airIRRP100GroupConfigAltitudeMetric,
|
|
-- airIRRP500GroupStatusActiveFlowControlStatus, airIRRP500GroupSetpointsActiveFlowControlBias, airIRRP500GroupConfigNumberOfActiveFlowControllers,
|
|
-- airIRRP500GroupConfigActiveFlowControllerLampTest, airIRRP500GroupConfigAltitudeUS, airIRRP500GroupConfigAltitudeMetric.
|
|
-- 2.Updated OIDs airIRRP100GroupConfigConfigurationType and airIRRP500GroupConfigConfigurationType to support CACS strategy.
|
|
-- 3.Added OIDs airIRRP100UnitConfigSecondaryPowerFeedCapability and airIRRP500UnitConfigSecondaryPowerFeedCapability
|
|
-- to support secondary power feed capability.
|
|
-- 4.Added OIDs airIRRP100UnitConfigIdleOnCoolFail and airIRRP500UnitConfigIdleOnCoolFail to support Idle on Cool Fail setting.
|
|
-- 5.Added OIDs airIRRP100GroupStatusDewPointTempUS, airIRRP100GroupStatusDewPointTempMetric, airIRRP500GroupStatusDewPointTempUS
|
|
-- and airIRRP500GroupStatusDewPointTempMetric to support the group dew point temperature.
|
|
-- 6.Added OIDs airIRRP100UnitStatusLeakSensor and airIRRP500UnitStatusLeakSensor to support leak sensor status.
|
|
-- 05/06/15 -v4.1.5 Added configurable contact OID rPDU2DeviceConfigContact.
|
|
-- Added enums for the chargerSpotmode, inverterSpotmode state in upsBasicOutputStatus OID and StaticBypassStandby state in the upsBasicSystemStatus OID.
|
|
-- Added new OIDs to support Active Flow Controller for airIRSC:
|
|
-- airIRSCGroupConfigNumberOfActiveFlowControllers, airIRSCGroupConfigActiveFlowControllerLampTest,
|
|
-- airIRSCGroupStatusActiveFlowControlStatus, airIRSCGroupSetpointsActiveFlowControlBias, airIRSCUnitStatusLeakSensor
|
|
-- 07/13/15 -v4.1.6 Changes for airIR Gen2 RD:
|
|
-- 1. Updated airIRG2GroupConfigConfigurationType to support CACS strategy.
|
|
-- 2. Added airIRG2RDT2StatusLeakSensor to support leak sensor status.
|
|
-- 3. Added OIDs to support Active Flow Controller:
|
|
-- airIRG2GroupStatusActiveFlowControlStatus,airIRG2GroupSetpointsActiveFlowControlBias,airIRG2GroupConfigNumberOfActiveFlowControllers,
|
|
-- airIRG2GroupConfigActiveFlowControllerLampTest,airIRG2GroupConfigAltitudeUS,airIRG2GroupConfigAltitudeMetric.
|
|
-- 08/05/15 -v4.1.7 Changes for SUMX and SY:
|
|
-- 1. Added upsAdvConfigBatteryHealthAlarmWarningTime and upsAdvConfigBatteryHealthAlarmSleepTime OIDs.
|
|
-- 2. Added upsDCOutput OIDs to support UPSes with DC outputs
|
|
-- 3. Added upsOnBatteryDueToFault and upsOnBatteryDueToFaultCleared for Symmetra UPSes.
|
|
|
|
-- ********************************************************************************************
|
|
-- ********************************************************************************************
|
|
-- PowerNet-MIB { iso org(3) dod(6) internet(1) private(4)
|
|
-- enterprises(1) apc(318) }
|
|
|
|
PowerNet-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises, IpAddress, Gauge, TimeTicks FROM RFC1155-SMI
|
|
DisplayString FROM RFC1213-MIB
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215;
|
|
-- IMPORTS End
|
|
|
|
apc OBJECT IDENTIFIER ::= { enterprises 318 }
|
|
|
|
products OBJECT IDENTIFIER ::= { apc 1 }
|
|
apcmgmt OBJECT IDENTIFIER ::= { apc 2 }
|
|
|
|
hardware OBJECT IDENTIFIER ::= { products 1 }
|
|
software OBJECT IDENTIFIER ::= { products 2 }
|
|
system OBJECT IDENTIFIER ::= { products 3 }
|
|
experimental OBJECT IDENTIFIER ::= { products 4 }
|
|
|
|
mconfig OBJECT IDENTIFIER ::= { apcmgmt 1 }
|
|
mcontrol OBJECT IDENTIFIER ::= { apcmgmt 2 }
|
|
mtrapargs OBJECT IDENTIFIER ::= { apcmgmt 3 }
|
|
mfiletransfer OBJECT IDENTIFIER ::= { apcmgmt 4 }
|
|
|
|
mconfigClock OBJECT IDENTIFIER ::= { mconfig 6 }
|
|
|
|
mfiletransferStatus OBJECT IDENTIFIER ::= { mfiletransfer 1 }
|
|
mfiletransferConfig OBJECT IDENTIFIER ::= { mfiletransfer 2 }
|
|
mfiletransferControl OBJECT IDENTIFIER ::= { mfiletransfer 3 }
|
|
|
|
mfiletransferConfigSettings OBJECT IDENTIFIER ::= { mfiletransferConfig 1 }
|
|
mfiletransferConfigTFTP OBJECT IDENTIFIER ::= { mfiletransferConfig 2 }
|
|
mfiletransferConfigFTP OBJECT IDENTIFIER ::= { mfiletransferConfig 3 }
|
|
|
|
ups OBJECT IDENTIFIER ::= { hardware 1 }
|
|
measureUps OBJECT IDENTIFIER ::= { hardware 2 }
|
|
miniSNMPadapter OBJECT IDENTIFIER ::= { hardware 3 }
|
|
masterswitch OBJECT IDENTIFIER ::= { hardware 4 }
|
|
masterswitchVM OBJECT IDENTIFIER ::= { hardware 5 }
|
|
masterswitchMSP OBJECT IDENTIFIER ::= { hardware 6 }
|
|
dcDM3 OBJECT IDENTIFIER ::= { hardware 7 }
|
|
automaticTransferSwitch OBJECT IDENTIFIER ::= { hardware 8 }
|
|
dc2 OBJECT IDENTIFIER ::= { hardware 9 }
|
|
environmentalMonitor OBJECT IDENTIFIER ::= { hardware 10 }
|
|
netlock OBJECT IDENTIFIER ::= { hardware 11 }
|
|
rPDU OBJECT IDENTIFIER ::= { hardware 12 }
|
|
airConditioners OBJECT IDENTIFIER ::= { hardware 13 }
|
|
rARU OBJECT IDENTIFIER ::= { hardware 14 }
|
|
xPDU OBJECT IDENTIFIER ::= { hardware 15 }
|
|
battMan OBJECT IDENTIFIER ::= { hardware 16 }
|
|
xATS OBJECT IDENTIFIER ::= { hardware 17 }
|
|
generator OBJECT IDENTIFIER ::= { hardware 18 }
|
|
consolePortServer OBJECT IDENTIFIER ::= { hardware 19 }
|
|
accessControl OBJECT IDENTIFIER ::= { hardware 20 }
|
|
apcLocalDisplay OBJECT IDENTIFIER ::= { hardware 21 }
|
|
isxModularDistribution OBJECT IDENTIFIER ::= { hardware 22 }
|
|
isxModularPdu OBJECT IDENTIFIER ::= { hardware 23 }
|
|
|
|
|
|
universalInputOutput OBJECT IDENTIFIER ::= { hardware 25 }
|
|
|
|
rPDU2 OBJECT IDENTIFIER ::= { hardware 26 }
|
|
|
|
|
|
cooling OBJECT IDENTIFIER ::= { hardware 27 }
|
|
|
|
|
|
powerNetSubAgent OBJECT IDENTIFIER ::= { software 1 }
|
|
|
|
struxureWareOperations OBJECT IDENTIFIER ::= { software 2 }
|
|
struxureWareOperationsStatus OBJECT IDENTIFIER ::= { struxureWareOperations 1 }
|
|
|
|
powerNetSoftwareSystem OBJECT IDENTIFIER ::= { powerNetSubAgent 1 }
|
|
powerNetSoftwareConfig OBJECT IDENTIFIER ::= { powerNetSubAgent 2 }
|
|
|
|
backUPS OBJECT IDENTIFIER ::= { system 1 }
|
|
smartUPS OBJECT IDENTIFIER ::= { system 2 }
|
|
matrixUPS OBJECT IDENTIFIER ::= { system 3 }
|
|
masterSwitch OBJECT IDENTIFIER ::= { system 4 }
|
|
symmetraUPS OBJECT IDENTIFIER ::= { system 5 }
|
|
dp100E OBJECT IDENTIFIER ::= { system 6 }
|
|
dp300E OBJECT IDENTIFIER ::= { system 7 }
|
|
monitors OBJECT IDENTIFIER ::= { system 8 }
|
|
redundantSwitch OBJECT IDENTIFIER ::= { system 9 }
|
|
dcPower OBJECT IDENTIFIER ::= { system 10 }
|
|
automaticXferSwitch OBJECT IDENTIFIER ::= { system 11 }
|
|
netLock OBJECT IDENTIFIER ::= { system 12 }
|
|
symmetra3PhaseUPS OBJECT IDENTIFIER ::= { system 13 }
|
|
networkAir OBJECT IDENTIFIER ::= { system 14 }
|
|
infraStruXurePDU OBJECT IDENTIFIER ::= { system 15 }
|
|
ais5000UPS OBJECT IDENTIFIER ::= { system 16 }
|
|
smartUPS3Phase OBJECT IDENTIFIER ::= { system 17 }
|
|
battManager OBJECT IDENTIFIER ::= { system 18 }
|
|
infraStruXureATS OBJECT IDENTIFIER ::= { system 19 }
|
|
conPortServ OBJECT IDENTIFIER ::= { system 20 }
|
|
gutor OBJECT IDENTIFIER ::= { system 21 }
|
|
accControl OBJECT IDENTIFIER ::= { system 22 }
|
|
symmetraPX OBJECT IDENTIFIER ::= { system 23 }
|
|
isxModDistribution OBJECT IDENTIFIER ::= { system 24 }
|
|
isxServers OBJECT IDENTIFIER ::= { system 25 }
|
|
smartUPS2 OBJECT IDENTIFIER ::= { system 27 }
|
|
galaxy OBJECT IDENTIFIER ::= { system 28 }
|
|
|
|
eps OBJECT IDENTIFIER ::= { system 30 }
|
|
|
|
battManIdent OBJECT IDENTIFIER ::= { battMan 1 }
|
|
battManSystemCalib OBJECT IDENTIFIER ::= { battMan 2 }
|
|
battManUnitCalib OBJECT IDENTIFIER ::= { battMan 3 }
|
|
battManStringCalib OBJECT IDENTIFIER ::= { battMan 4 }
|
|
battManBatteryCalib OBJECT IDENTIFIER ::= { battMan 5 }
|
|
battManConfig OBJECT IDENTIFIER ::= { battMan 6 }
|
|
battManAlarm OBJECT IDENTIFIER ::= { battMan 7 }
|
|
battManSystemStatus OBJECT IDENTIFIER ::= { battMan 8 }
|
|
battManStringStatus OBJECT IDENTIFIER ::= { battMan 9 }
|
|
battManBatteryStatus OBJECT IDENTIFIER ::= { battMan 10 }
|
|
battManInputContactStatus OBJECT IDENTIFIER ::= { battMan 11 }
|
|
battManControl OBJECT IDENTIFIER ::= { battMan 12 }
|
|
battManTestResults OBJECT IDENTIFIER ::= { battMan 13 }
|
|
battManUnitStatus OBJECT IDENTIFIER ::= { battMan 14 }
|
|
|
|
xPDUIdent OBJECT IDENTIFIER ::= { xPDU 1 }
|
|
xPDUDevice OBJECT IDENTIFIER ::= { xPDU 2 }
|
|
xPDUACMonitoringPoint OBJECT IDENTIFIER ::= { xPDU 3 }
|
|
xPDUCircuitBreakers OBJECT IDENTIFIER ::= { xPDU 4 }
|
|
xPDUInputContacts OBJECT IDENTIFIER ::= { xPDU 5 }
|
|
xPDUOutputRelays OBJECT IDENTIFIER ::= { xPDU 6 }
|
|
xPDUMiscGroup OBJECT IDENTIFIER ::= { xPDU 7 }
|
|
|
|
xPDUMainInput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 1 }
|
|
xPDUBypassInput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 2 }
|
|
xPDUUPSInput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 3 }
|
|
xPDUSystemOutput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 4 }
|
|
xPDUGroundMonitorPoint OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 5 }
|
|
|
|
xPDUSystemBreakers OBJECT IDENTIFIER ::= { xPDUCircuitBreakers 1 }
|
|
xPDUBranchBreakers OBJECT IDENTIFIER ::= { xPDUCircuitBreakers 2 }
|
|
|
|
xATSIdent OBJECT IDENTIFIER ::= { xATS 1 }
|
|
xATSDevice OBJECT IDENTIFIER ::= { xATS 2 }
|
|
xATSSwitch OBJECT IDENTIFIER ::= { xATS 3 }
|
|
xATSACMonitoringPoint OBJECT IDENTIFIER ::= { xATS 4 }
|
|
xATSTesting OBJECT IDENTIFIER ::= { xATS 5 }
|
|
xATSInputContacts OBJECT IDENTIFIER ::= { xATS 6 }
|
|
xATSOutputRelays OBJECT IDENTIFIER ::= { xATS 7 }
|
|
xATSMisc OBJECT IDENTIFIER ::= { xATS 8 }
|
|
|
|
xATSSwitchStatus OBJECT IDENTIFIER ::= { xATSSwitch 1 }
|
|
xATSSwitchSettings OBJECT IDENTIFIER ::= { xATSSwitch 2 }
|
|
xATSSwitchTimers OBJECT IDENTIFIER ::= { xATSSwitch 3 }
|
|
xATSSwitchBlockMap OBJECT IDENTIFIER ::= { xATSSwitch 4 }
|
|
xATSSwitchStatistics OBJECT IDENTIFIER ::= { xATSSwitch 5 }
|
|
|
|
xATSSource1 OBJECT IDENTIFIER ::= { xATSACMonitoringPoint 1 }
|
|
xATSSource2 OBJECT IDENTIFIER ::= { xATSACMonitoringPoint 2 }
|
|
xATSSystemOutput OBJECT IDENTIFIER ::= { xATSACMonitoringPoint 3 }
|
|
|
|
xATSTestingStatus OBJECT IDENTIFIER ::= { xATSTesting 1 }
|
|
xATSTestingResults OBJECT IDENTIFIER ::= { xATSTesting 2 }
|
|
xATSTestingSchedule OBJECT IDENTIFIER ::= { xATSTesting 3 }
|
|
xATSTestingSimulatePowerFail OBJECT IDENTIFIER ::= { xATSTesting 4 }
|
|
|
|
xATSGenerator OBJECT IDENTIFIER ::= { generator 1 }
|
|
|
|
xATSGeneratorIdent OBJECT IDENTIFIER ::= { xATSGenerator 1 }
|
|
xATSGeneratorStatus OBJECT IDENTIFIER ::= { xATSGenerator 2 }
|
|
xATSGeneratorAdvStatus OBJECT IDENTIFIER ::= { xATSGenerator 3 }
|
|
xATSGeneratorOutput OBJECT IDENTIFIER ::= { xATSGenerator 4 }
|
|
xATSGeneratorSettings OBJECT IDENTIFIER ::= { xATSGenerator 5 }
|
|
xATSGeneratorService OBJECT IDENTIFIER ::= { xATSGenerator 6 }
|
|
xATSGeneratorFuelSystem OBJECT IDENTIFIER ::= { xATSGenerator 7 }
|
|
|
|
cpsAP930x OBJECT IDENTIFIER ::= { consolePortServer 1 }
|
|
|
|
cpsAP930xSys OBJECT IDENTIFIER ::= { cpsAP930x 1 }
|
|
cpsAP930xConf OBJECT IDENTIFIER ::= { cpsAP930x 2 }
|
|
cpsAP930xInfo OBJECT IDENTIFIER ::= { cpsAP930x 3 }
|
|
cpsAP930xAdm OBJECT IDENTIFIER ::= { cpsAP930x 4 }
|
|
|
|
|
|
|
|
smartUPS250 OBJECT IDENTIFIER ::= { smartUPS 1 }
|
|
smartUPS400 OBJECT IDENTIFIER ::= { smartUPS 2 }
|
|
smartUPS600 OBJECT IDENTIFIER ::= { smartUPS 3 }
|
|
smartUPS900 OBJECT IDENTIFIER ::= { smartUPS 4 }
|
|
smartUPS1250 OBJECT IDENTIFIER ::= { smartUPS 5 }
|
|
smartUPS2000 OBJECT IDENTIFIER ::= { smartUPS 6 }
|
|
|
|
smartUPS450 OBJECT IDENTIFIER ::= { smartUPS 7 }
|
|
smartUPS700 OBJECT IDENTIFIER ::= { smartUPS 8 }
|
|
smartUPS1000 OBJECT IDENTIFIER ::= { smartUPS 9 }
|
|
smartUPS1400 OBJECT IDENTIFIER ::= { smartUPS 10 }
|
|
smartUPS2200 OBJECT IDENTIFIER ::= { smartUPS 11 }
|
|
smartUPS3000 OBJECT IDENTIFIER ::= { smartUPS 12 }
|
|
smartUPS5000 OBJECT IDENTIFIER ::= { smartUPS 13 }
|
|
smartUPS7500 OBJECT IDENTIFIER ::= { smartUPS 14 }
|
|
smartUPS10000 OBJECT IDENTIFIER ::= { smartUPS 15 }
|
|
smartUPS1500 OBJECT IDENTIFIER ::= { smartUPS 16 }
|
|
smartUPS3000DSP OBJECT IDENTIFIER ::= { smartUPS 17 }
|
|
smartUPS5000DSP OBJECT IDENTIFIER ::= { smartUPS 18 }
|
|
smartUPS8000 OBJECT IDENTIFIER ::= { smartUPS 19 }
|
|
|
|
matrixUPS3000 OBJECT IDENTIFIER ::= { matrixUPS 1 }
|
|
matrixUPS5000 OBJECT IDENTIFIER ::= { matrixUPS 2 }
|
|
|
|
masterSwitchV1 OBJECT IDENTIFIER ::= { masterSwitch 1}
|
|
masterSwitchV2 OBJECT IDENTIFIER ::= { masterSwitch 2}
|
|
masterSwitchVM OBJECT IDENTIFIER ::= { masterSwitch 3}
|
|
masterSwitchMSP OBJECT IDENTIFIER ::= { masterSwitch 4}
|
|
masterSwitchrPDU OBJECT IDENTIFIER ::= { masterSwitch 5}
|
|
masterSwitchrPDU2 OBJECT IDENTIFIER ::= { masterSwitch 6}
|
|
masterSwitchsPDU OBJECT IDENTIFIER ::= { masterSwitch 7}
|
|
|
|
symmetraUPS4kVA OBJECT IDENTIFIER ::= { symmetraUPS 1 }
|
|
symmetraUPS8kVA OBJECT IDENTIFIER ::= { symmetraUPS 2 }
|
|
symmetraUPS12kVA OBJECT IDENTIFIER ::= { symmetraUPS 3 }
|
|
symmetraUPS16kVA OBJECT IDENTIFIER ::= { symmetraUPS 4 }
|
|
|
|
environmental OBJECT IDENTIFIER ::= { monitors 1 }
|
|
environmentalMgtSystem OBJECT IDENTIFIER ::= { monitors 2 }
|
|
emu2 OBJECT IDENTIFIER ::= { monitors 3 }
|
|
mem OBJECT IDENTIFIER ::= { monitors 4 }
|
|
|
|
dm3 OBJECT IDENTIFIER ::= { dcPower 1 }
|
|
dcmim2 OBJECT IDENTIFIER ::= { dcPower 2 }
|
|
|
|
symmetra3PhaseUPS40kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 1 }
|
|
symmetra3PhaseUPS60kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 2 }
|
|
symmetra3PhaseUPS80kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 3 }
|
|
symmetra3PhaseUPS20kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 4 }
|
|
|
|
airFMSeries OBJECT IDENTIFIER ::= { networkAir 1 }
|
|
rackAirRemovalUnit OBJECT IDENTIFIER ::= { networkAir 2 }
|
|
airPASeries OBJECT IDENTIFIER ::= { networkAir 3 }
|
|
airIRSC100Series OBJECT IDENTIFIER ::= { networkAir 4 }
|
|
airIRRC100Series OBJECT IDENTIFIER ::= { networkAir 5 }
|
|
airIRRP100Series OBJECT IDENTIFIER ::= { networkAir 6 }
|
|
airIRRP500Series OBJECT IDENTIFIER ::= { networkAir 7 }
|
|
airIRRD100Series OBJECT IDENTIFIER ::= { networkAir 8 }
|
|
airInRoomPerimeter OBJECT IDENTIFIER ::= { networkAir 9 }
|
|
airACRC300Series OBJECT IDENTIFIER ::= { networkAir 10 }
|
|
airLESeries OBJECT IDENTIFIER ::= { networkAir 11 }
|
|
airIRRDU OBJECT IDENTIFIER ::= { networkAir 12 }
|
|
airEcoBreeze OBJECT IDENTIFIER ::= { networkAir 13 }
|
|
airLELSeries OBJECT IDENTIFIER ::= { networkAir 14 }
|
|
airACRC600Series OBJECT IDENTIFIER ::= { networkAir 15 }
|
|
airACRD600Series OBJECT IDENTIFIER ::= { networkAir 16 }
|
|
|
|
ais5000UPS10kVA OBJECT IDENTIFIER ::= { ais5000UPS 1 }
|
|
ais5000UPS20kVA OBJECT IDENTIFIER ::= { ais5000UPS 2 }
|
|
ais5000UPS30kVA OBJECT IDENTIFIER ::= { ais5000UPS 3 }
|
|
ais5000UPS40kVA OBJECT IDENTIFIER ::= { ais5000UPS 4 }
|
|
ais5000UPS60kVA OBJECT IDENTIFIER ::= { ais5000UPS 5 }
|
|
ais5000UPS80kVA OBJECT IDENTIFIER ::= { ais5000UPS 6 }
|
|
ais5000UPS100kVA OBJECT IDENTIFIER ::= { ais5000UPS 7 }
|
|
|
|
smartUPS3Phase10kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 1 }
|
|
smartUPS3Phase15kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 2 }
|
|
smartUPS3Phase20kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 3 }
|
|
smartUPS3Phase30kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 4 }
|
|
smartUPS3Phase40kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 5 }
|
|
|
|
galaxy7000UPS200kVA OBJECT IDENTIFIER ::= { galaxy 1 }
|
|
galaxy7000UPS250kVA OBJECT IDENTIFIER ::= { galaxy 2 }
|
|
galaxy7000UPS300kVA OBJECT IDENTIFIER ::= { galaxy 3 }
|
|
galaxy7000UPS400kVA OBJECT IDENTIFIER ::= { galaxy 4 }
|
|
galaxy7000UPS500kVA OBJECT IDENTIFIER ::= { galaxy 5 }
|
|
galaxy7000SSC800kVA OBJECT IDENTIFIER ::= { galaxy 6 }
|
|
galaxy7000SSC1200kVA OBJECT IDENTIFIER ::= { galaxy 7 }
|
|
galaxy7000SSC2000kVA OBJECT IDENTIFIER ::= { galaxy 8 }
|
|
galaxy300UPS10kVA33 OBJECT IDENTIFIER ::= { galaxy 9 }
|
|
galaxy300UPS15kVA33 OBJECT IDENTIFIER ::= { galaxy 10 }
|
|
galaxy300UPS20kVA33 OBJECT IDENTIFIER ::= { galaxy 11 }
|
|
galaxy300UPS30kVA33 OBJECT IDENTIFIER ::= { galaxy 12 }
|
|
galaxy300UPS40kVA33 OBJECT IDENTIFIER ::= { galaxy 13 }
|
|
galaxy300UPS10kVA31 OBJECT IDENTIFIER ::= { galaxy 14 }
|
|
galaxy300UPS15kVA31 OBJECT IDENTIFIER ::= { galaxy 15 }
|
|
galaxy300UPS20kVA31 OBJECT IDENTIFIER ::= { galaxy 16 }
|
|
galaxy300UPS30kVA31 OBJECT IDENTIFIER ::= { galaxy 17 }
|
|
|
|
galaxy5000UPS20KVA OBJECT IDENTIFIER ::= { galaxy 18 }
|
|
galaxy5000UPS30KVA OBJECT IDENTIFIER ::= { galaxy 19 }
|
|
galaxy5000UPS40KVA OBJECT IDENTIFIER ::= { galaxy 20 }
|
|
galaxy5000UPS50KVA OBJECT IDENTIFIER ::= { galaxy 21 }
|
|
galaxy5000UPS60KVA OBJECT IDENTIFIER ::= { galaxy 22 }
|
|
galaxy5000UPS80KVA OBJECT IDENTIFIER ::= { galaxy 23 }
|
|
galaxy5000UPS100KVA OBJECT IDENTIFIER ::= { galaxy 24 }
|
|
galaxy5000UPS120KVA OBJECT IDENTIFIER ::= { galaxy 25 }
|
|
galaxy5000UPS130KVA OBJECT IDENTIFIER ::= { galaxy 26 }
|
|
galaxy5500UPS20KVA OBJECT IDENTIFIER ::= { galaxy 27 }
|
|
galaxy5500UPS30KVA OBJECT IDENTIFIER ::= { galaxy 28 }
|
|
galaxy5500UPS40KVA OBJECT IDENTIFIER ::= { galaxy 29 }
|
|
galaxy5500UPS50KVA OBJECT IDENTIFIER ::= { galaxy 30 }
|
|
galaxy5500UPS60KVA OBJECT IDENTIFIER ::= { galaxy 31 }
|
|
galaxy5500UPS80KVA OBJECT IDENTIFIER ::= { galaxy 32 }
|
|
galaxy5500UPS100KVA OBJECT IDENTIFIER ::= { galaxy 33 }
|
|
galaxy5500UPS120KVA OBJECT IDENTIFIER ::= { galaxy 34 }
|
|
galaxy5500UPS130KVA OBJECT IDENTIFIER ::= { galaxy 35 }
|
|
|
|
|
|
|
|
galaxyVMUPS50kVA OBJECT IDENTIFIER ::= { galaxy 36 }
|
|
galaxyVMUPS60kVA OBJECT IDENTIFIER ::= { galaxy 37 }
|
|
galaxyVMUPS80kVA OBJECT IDENTIFIER ::= { galaxy 38 }
|
|
galaxyVMUPS90kVA OBJECT IDENTIFIER ::= { galaxy 39 }
|
|
galaxyVMUPS100kVA OBJECT IDENTIFIER ::= { galaxy 40 }
|
|
galaxyVMUPS110kVA OBJECT IDENTIFIER ::= { galaxy 41 }
|
|
galaxyVMUPS120kVA OBJECT IDENTIFIER ::= { galaxy 42 }
|
|
galaxyVMUPS130kVA OBJECT IDENTIFIER ::= { galaxy 43 }
|
|
galaxyVMUPS160kVA OBJECT IDENTIFIER ::= { galaxy 44 }
|
|
galaxyVMUPS180kVA OBJECT IDENTIFIER ::= { galaxy 45 }
|
|
galaxyVMUPS200kVA OBJECT IDENTIFIER ::= { galaxy 46 }
|
|
galaxyVMUPS225kVA OBJECT IDENTIFIER ::= { galaxy 47 }
|
|
|
|
|
|
galaxy9000UPS OBJECT IDENTIFIER ::= { galaxy 48 }
|
|
galaxy9000SSC OBJECT IDENTIFIER ::= { galaxy 49 }
|
|
galaxy9000UPSWithSSC OBJECT IDENTIFIER ::= { galaxy 50 }
|
|
galaxy9000FreqConverter OBJECT IDENTIFIER ::= { galaxy 51 }
|
|
|
|
|
|
|
|
|
|
|
|
eps6000UPS OBJECT IDENTIFIER ::= { eps 1 }
|
|
eps6000SSC OBJECT IDENTIFIER ::= { eps 2 }
|
|
eps6000UPSWithSSC OBJECT IDENTIFIER ::= { eps 3 }
|
|
eps6000FreqConverter OBJECT IDENTIFIER ::= { eps 4 }
|
|
eps7000UPS OBJECT IDENTIFIER ::= { eps 5 }
|
|
eps7000SSC OBJECT IDENTIFIER ::= { eps 6 }
|
|
eps7000UPSWithSSC OBJECT IDENTIFIER ::= { eps 7 }
|
|
eps7000FreqConverter OBJECT IDENTIFIER ::= { eps 8 }
|
|
eps8000UPS OBJECT IDENTIFIER ::= { eps 9 }
|
|
eps8000SSC OBJECT IDENTIFIER ::= { eps 10 }
|
|
eps8000UPSWithSSC OBJECT IDENTIFIER ::= { eps 11 }
|
|
eps8000FreqConverter OBJECT IDENTIFIER ::= { eps 12 }
|
|
|
|
|
|
conPortServAP930x OBJECT IDENTIFIER ::= { conPortServ 1 }
|
|
|
|
gutorPEW OBJECT IDENTIFIER ::= { gutor 1 }
|
|
gutorPDW OBJECT IDENTIFIER ::= { gutor 2 }
|
|
gutorWEW OBJECT IDENTIFIER ::= { gutor 3 }
|
|
gutorWDW OBJECT IDENTIFIER ::= { gutor 4 }
|
|
gutorSDC OBJECT IDENTIFIER ::= { gutor 5 }
|
|
|
|
upsIdent OBJECT IDENTIFIER ::= { ups 1 }
|
|
upsBattery OBJECT IDENTIFIER ::= { ups 2 }
|
|
upsInput OBJECT IDENTIFIER ::= { ups 3 }
|
|
upsOutput OBJECT IDENTIFIER ::= { ups 4 }
|
|
upsConfig OBJECT IDENTIFIER ::= { ups 5 }
|
|
upsControl OBJECT IDENTIFIER ::= { ups 6 }
|
|
upsTest OBJECT IDENTIFIER ::= { ups 7 }
|
|
upsComm OBJECT IDENTIFIER ::= { ups 8 }
|
|
upsPhase OBJECT IDENTIFIER ::= { ups 9 }
|
|
upsSyncCtrlGroup OBJECT IDENTIFIER ::= { ups 10 }
|
|
upsState OBJECT IDENTIFIER ::= { ups 11 }
|
|
upsOutletGroups OBJECT IDENTIFIER ::= { ups 12 }
|
|
upsDiagnostics OBJECT IDENTIFIER ::= { ups 13 }
|
|
upsParallelSystem OBJECT IDENTIFIER ::= { ups 14 }
|
|
upsPhysicalLayout OBJECT IDENTIFIER ::= { ups 15 }
|
|
upsIntegratedATS OBJECT IDENTIFIER ::= { ups 16 }
|
|
upsDCOutput OBJECT IDENTIFIER ::= { ups 17 }
|
|
|
|
upsBasicIdent OBJECT IDENTIFIER ::= { upsIdent 1 }
|
|
upsAdvIdent OBJECT IDENTIFIER ::= { upsIdent 2 }
|
|
|
|
upsBasicBattery OBJECT IDENTIFIER ::= { upsBattery 1 }
|
|
upsAdvBattery OBJECT IDENTIFIER ::= { upsBattery 2 }
|
|
upsHighPrecBattery OBJECT IDENTIFIER ::= { upsBattery 3 }
|
|
|
|
upsBasicInput OBJECT IDENTIFIER ::= { upsInput 1 }
|
|
upsAdvInput OBJECT IDENTIFIER ::= { upsInput 2 }
|
|
upsHighPrecInput OBJECT IDENTIFIER ::= { upsInput 3 }
|
|
|
|
upsBasicOutput OBJECT IDENTIFIER ::= { upsOutput 1 }
|
|
upsAdvOutput OBJECT IDENTIFIER ::= { upsOutput 2 }
|
|
upsHighPrecOutput OBJECT IDENTIFIER ::= { upsOutput 3 }
|
|
|
|
upsBasicConfig OBJECT IDENTIFIER ::= { upsConfig 1 }
|
|
upsAdvConfig OBJECT IDENTIFIER ::= { upsConfig 2 }
|
|
|
|
|
|
upsBasicControl OBJECT IDENTIFIER ::= { upsControl 1 }
|
|
upsAdvControl OBJECT IDENTIFIER ::= { upsControl 2 }
|
|
|
|
upsBasicTest OBJECT IDENTIFIER ::= { upsTest 1 }
|
|
upsAdvTest OBJECT IDENTIFIER ::= { upsTest 2 }
|
|
|
|
upsPhaseResetValues OBJECT IDENTIFIER ::= { upsPhase 1 }
|
|
upsPhaseInput OBJECT IDENTIFIER ::= { upsPhase 2 }
|
|
upsPhaseOutput OBJECT IDENTIFIER ::= { upsPhase 3 }
|
|
|
|
upsSyncCtrlGroupConfig OBJECT IDENTIFIER ::= { upsSyncCtrlGroup 1 }
|
|
upsSyncCtrlGroupStatus OBJECT IDENTIFIER ::= { upsSyncCtrlGroup 2 }
|
|
|
|
upsBasicState OBJECT IDENTIFIER ::= { upsState 1 }
|
|
upsAdvState OBJECT IDENTIFIER ::= { upsState 2 }
|
|
|
|
upsOutletGroupStatus OBJECT IDENTIFIER ::= { upsOutletGroups 1 }
|
|
upsOutletGroupConfig OBJECT IDENTIFIER ::= { upsOutletGroups 2 }
|
|
upsOutletGroupControl OBJECT IDENTIFIER ::= { upsOutletGroups 3 }
|
|
|
|
upsDiagnosticIM OBJECT IDENTIFIER ::= { upsDiagnostics 1 }
|
|
upsDiagnosticPowerModules OBJECT IDENTIFIER ::= { upsDiagnostics 2 }
|
|
upsDiagnosticBatteries OBJECT IDENTIFIER ::= { upsDiagnostics 3 }
|
|
upsDiagnosticSubsystem OBJECT IDENTIFIER ::= { upsDiagnostics 4 }
|
|
upsDiagnosticExternalDevices OBJECT IDENTIFIER ::= { upsDiagnostics 5 }
|
|
upsDiagnosticComBus OBJECT IDENTIFIER ::= { upsDiagnostics 6 }
|
|
|
|
upsDiagSwitchGear OBJECT IDENTIFIER ::= { upsDiagnosticExternalDevices 1 }
|
|
upsDiagMCCBBox OBJECT IDENTIFIER ::= { upsDiagnosticExternalDevices 2 }
|
|
upsDiagTransformer OBJECT IDENTIFIER ::= { upsDiagnosticExternalDevices 3 }
|
|
|
|
upsDiagFlyWheel OBJECT IDENTIFIER ::= { upsDiagnosticExternalDevices 4 }
|
|
|
|
|
|
mUpsEnviron OBJECT IDENTIFIER ::= { measureUps 1 }
|
|
mUpsContact OBJECT IDENTIFIER ::= { measureUps 2 }
|
|
|
|
serialPort OBJECT IDENTIFIER ::= { miniSNMPadapter 1}
|
|
|
|
serialPort1 OBJECT IDENTIFIER ::= { serialPort 1}
|
|
serialPort2 OBJECT IDENTIFIER ::= { serialPort 2}
|
|
|
|
serialPort2Config OBJECT IDENTIFIER ::= { serialPort2 1}
|
|
serialPort2Control OBJECT IDENTIFIER ::= { serialPort2 2}
|
|
|
|
sPDUIdent OBJECT IDENTIFIER ::= { masterswitch 1 }
|
|
sPDUMasterControl OBJECT IDENTIFIER ::= { masterswitch 2 }
|
|
sPDUMasterConfig OBJECT IDENTIFIER ::= { masterswitch 3 }
|
|
sPDUOutletControl OBJECT IDENTIFIER ::= { masterswitch 4 }
|
|
sPDUOutletConfig OBJECT IDENTIFIER ::= { masterswitch 5 }
|
|
|
|
sPDUIdentVM OBJECT IDENTIFIER ::= { masterswitchVM 1 }
|
|
sPDUMasterControlVM OBJECT IDENTIFIER ::= { masterswitchVM 2 }
|
|
sPDUMasterConfigVM OBJECT IDENTIFIER ::= { masterswitchVM 3 }
|
|
sPDUMasterStatusVM OBJECT IDENTIFIER ::= { masterswitchVM 4 }
|
|
sPDUOutletControlVM OBJECT IDENTIFIER ::= { masterswitchVM 5 }
|
|
sPDUOutletConfigVM OBJECT IDENTIFIER ::= { masterswitchVM 6 }
|
|
sPDUOutletStatusVM OBJECT IDENTIFIER ::= { masterswitchVM 7 }
|
|
|
|
sPDUIdentMSP OBJECT IDENTIFIER ::= { masterswitchMSP 1 }
|
|
sPDUMasterControlMSP OBJECT IDENTIFIER ::= { masterswitchMSP 2 }
|
|
sPDUMasterConfigMSP OBJECT IDENTIFIER ::= { masterswitchMSP 3 }
|
|
sPDUMasterStatusMSP OBJECT IDENTIFIER ::= { masterswitchMSP 4 }
|
|
sPDUOutletControlMSP OBJECT IDENTIFIER ::= { masterswitchMSP 5 }
|
|
sPDUOutletConfigMSP OBJECT IDENTIFIER ::= { masterswitchMSP 6 }
|
|
sPDUOutletStatusMSP OBJECT IDENTIFIER ::= { masterswitchMSP 7 }
|
|
|
|
sPDUOutletConfigMSPall OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 1 }
|
|
sPDUOutletConfigMSPgs OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 2 }
|
|
sPDUOutletConfigMSPannun OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 3 }
|
|
sPDUOutletConfigMSPmups OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 4 }
|
|
|
|
rPDUIdent OBJECT IDENTIFIER ::= { rPDU 1 }
|
|
rPDULoad OBJECT IDENTIFIER ::= { rPDU 2 }
|
|
rPDUOutlet OBJECT IDENTIFIER ::= { rPDU 3 }
|
|
rPDUPowerSupply OBJECT IDENTIFIER ::= { rPDU 4 }
|
|
rPDUStatus OBJECT IDENTIFIER ::= { rPDU 5 }
|
|
|
|
rPDULoadDevice OBJECT IDENTIFIER ::= { rPDULoad 1 }
|
|
rPDULoadPhaseConfig OBJECT IDENTIFIER ::= { rPDULoad 2 }
|
|
rPDULoadStatus OBJECT IDENTIFIER ::= { rPDULoad 3 }
|
|
rPDULoadBankConfig OBJECT IDENTIFIER ::= { rPDULoad 4 }
|
|
|
|
rPDUOutletDevice OBJECT IDENTIFIER ::= { rPDUOutlet 1 }
|
|
rPDUOutletPhase OBJECT IDENTIFIER ::= { rPDUOutlet 2 }
|
|
rPDUOutletControl OBJECT IDENTIFIER ::= { rPDUOutlet 3 }
|
|
rPDUOutletConfig OBJECT IDENTIFIER ::= { rPDUOutlet 4 }
|
|
rPDUOutletStatus OBJECT IDENTIFIER ::= { rPDUOutlet 5 }
|
|
rPDUOutletBank OBJECT IDENTIFIER ::= { rPDUOutlet 6 }
|
|
|
|
rPDUPowerSupplyDevice OBJECT IDENTIFIER ::= { rPDUPowerSupply 1 }
|
|
|
|
dm3Ident OBJECT IDENTIFIER ::= { dcDM3 1 }
|
|
dm3Config OBJECT IDENTIFIER ::= { dcDM3 2 }
|
|
dm3Status OBJECT IDENTIFIER ::= { dcDM3 3 }
|
|
|
|
dm3IdentSystem OBJECT IDENTIFIER ::= { dm3Ident 1}
|
|
|
|
dm3ConfigSystem OBJECT IDENTIFIER ::= { dm3Config 1 }
|
|
dm3ConfigLVD OBJECT IDENTIFIER ::= { dm3Config 2 }
|
|
dm3ConfigBattery OBJECT IDENTIFIER ::= { dm3Config 3 }
|
|
dm3ConfigPowerModules OBJECT IDENTIFIER ::= { dm3Config 4 }
|
|
dm3ConfigRelays OBJECT IDENTIFIER ::= { dm3Config 5 }
|
|
dm3ConfigDistribution OBJECT IDENTIFIER ::= { dm3Config 6 }
|
|
|
|
dm3ConfigRectifier OBJECT IDENTIFIER ::= { dm3ConfigPowerModules 1 }
|
|
dm3ConfigConverter OBJECT IDENTIFIER ::= { dm3ConfigPowerModules 2 }
|
|
|
|
dm3ConfigRectThresh OBJECT IDENTIFIER ::= { dm3ConfigRectifier 1 }
|
|
dm3ConfigRectAlarms OBJECT IDENTIFIER ::= { dm3ConfigRectifier 2 }
|
|
|
|
dm3ConfigConvThresh OBJECT IDENTIFIER ::= { dm3ConfigConverter 1 }
|
|
dm3ConfigConvAlarms OBJECT IDENTIFIER ::= { dm3ConfigConverter 2 }
|
|
|
|
dm3ConfigOutputRelays OBJECT IDENTIFIER ::= { dm3ConfigRelays 1 }
|
|
dm3ConfigInputRelays OBJECT IDENTIFIER ::= { dm3ConfigRelays 2 }
|
|
|
|
dm3ConfigBreakers OBJECT IDENTIFIER ::= { dm3ConfigDistribution 1 }
|
|
dm3ConfigFuses OBJECT IDENTIFIER ::= { dm3ConfigDistribution 2 }
|
|
|
|
dm3StatusSystem OBJECT IDENTIFIER ::= { dm3Status 1 }
|
|
dm3StatusAlarms OBJECT IDENTIFIER ::= { dm3Status 2 }
|
|
dm3StatusBattery OBJECT IDENTIFIER ::= { dm3Status 3 }
|
|
dm3StatusOEM OBJECT IDENTIFIER ::= { dm3Status 4 }
|
|
dm3StatusLVD OBJECT IDENTIFIER ::= { dm3Status 5 }
|
|
dm3StatusPowerModules OBJECT IDENTIFIER ::= { dm3Status 6 }
|
|
dm3StatusRelays OBJECT IDENTIFIER ::= { dm3Status 7 }
|
|
dm3StatusDistribution OBJECT IDENTIFIER ::= { dm3Status 8 }
|
|
|
|
dm3StatusRectifier OBJECT IDENTIFIER ::= { dm3StatusPowerModules 1 }
|
|
dm3StatusConverter OBJECT IDENTIFIER ::= { dm3StatusPowerModules 2 }
|
|
|
|
dm3StatusOutputRelays OBJECT IDENTIFIER ::= { dm3StatusRelays 1 }
|
|
dm3StatusInputRelays OBJECT IDENTIFIER ::= { dm3StatusRelays 2 }
|
|
|
|
dm3StatusBreakers OBJECT IDENTIFIER ::= { dm3StatusDistribution 1 }
|
|
dm3StatusFuses OBJECT IDENTIFIER ::= { dm3StatusDistribution 2 }
|
|
|
|
atsIdent OBJECT IDENTIFIER ::= { automaticTransferSwitch 1 }
|
|
atsCalibration OBJECT IDENTIFIER ::= { automaticTransferSwitch 2 }
|
|
atsControl OBJECT IDENTIFIER ::= { automaticTransferSwitch 3 }
|
|
atsConfig OBJECT IDENTIFIER ::= { automaticTransferSwitch 4 }
|
|
atsStatus OBJECT IDENTIFIER ::= { automaticTransferSwitch 5 }
|
|
|
|
atsCalibrationInput OBJECT IDENTIFIER ::= { atsCalibration 1 }
|
|
atsCalibrationPowerSupply OBJECT IDENTIFIER ::= { atsCalibration 2 }
|
|
atsCalibrationOutput OBJECT IDENTIFIER ::= { atsCalibration 3 }
|
|
|
|
atsStatusDeviceStatus OBJECT IDENTIFIER ::= { atsStatus 1 }
|
|
atsStatusResetValues OBJECT IDENTIFIER ::= { atsStatus 2 }
|
|
atsStatusInput OBJECT IDENTIFIER ::= { atsStatus 3 }
|
|
atsStatusOutput OBJECT IDENTIFIER ::= { atsStatus 4 }
|
|
|
|
dcmim2Ident OBJECT IDENTIFIER ::= { dc2 1 }
|
|
dcmim2Control OBJECT IDENTIFIER ::= { dc2 2 }
|
|
dcmim2Config OBJECT IDENTIFIER ::= { dc2 3 }
|
|
dcmim2Status OBJECT IDENTIFIER ::= { dc2 4 }
|
|
|
|
dcmim2IdentSystem OBJECT IDENTIFIER ::= { dcmim2Ident 1 }
|
|
|
|
dcmim2ControlSystem OBJECT IDENTIFIER ::= { dcmim2Control 1 }
|
|
|
|
dcmim2ConfigSystem OBJECT IDENTIFIER ::= { dcmim2Config 1 }
|
|
dcmim2ConfigBattery OBJECT IDENTIFIER ::= { dcmim2Config 2 }
|
|
dcmim2ConfigLVD OBJECT IDENTIFIER ::= { dcmim2Config 3 }
|
|
|
|
dcmim2StatusSystem OBJECT IDENTIFIER ::= { dcmim2Status 1 }
|
|
dcmim2StatusRectifier OBJECT IDENTIFIER ::= { dcmim2Status 2 }
|
|
dcmim2StatusBattery OBJECT IDENTIFIER ::= { dcmim2Status 3 }
|
|
dcmim2StatusLVD OBJECT IDENTIFIER ::= { dcmim2Status 4 }
|
|
dcmim2StatusAlarms OBJECT IDENTIFIER ::= { dcmim2Status 5 }
|
|
|
|
external OBJECT IDENTIFIER ::= { environmentalMonitor 1 }
|
|
integrated OBJECT IDENTIFIER ::= { environmentalMonitor 2 }
|
|
envMgtSystem OBJECT IDENTIFIER ::= { environmentalMonitor 3 }
|
|
modEnvMgr OBJECT IDENTIFIER ::= { environmentalMonitor 4 }
|
|
|
|
emIdent OBJECT IDENTIFIER ::= { external 1 }
|
|
emConfig OBJECT IDENTIFIER ::= { external 2 }
|
|
emStatus OBJECT IDENTIFIER ::= { external 3 }
|
|
|
|
iemIdent OBJECT IDENTIFIER ::= { integrated 1 }
|
|
iemConfig OBJECT IDENTIFIER ::= { integrated 2 }
|
|
iemStatus OBJECT IDENTIFIER ::= { integrated 3 }
|
|
|
|
emsIdent OBJECT IDENTIFIER ::= { envMgtSystem 1 }
|
|
|
|
emsOutputRelayControl OBJECT IDENTIFIER ::= { envMgtSystem 2 }
|
|
emsOutletControl OBJECT IDENTIFIER ::= { envMgtSystem 3 }
|
|
emsSensorControl OBJECT IDENTIFIER ::= { envMgtSystem 4 }
|
|
emsAlarmDeviceControl OBJECT IDENTIFIER ::= { envMgtSystem 5 }
|
|
|
|
emsConfig OBJECT IDENTIFIER ::= { envMgtSystem 6 }
|
|
emsProbeConfig OBJECT IDENTIFIER ::= { envMgtSystem 7 }
|
|
emsInputContactConfig OBJECT IDENTIFIER ::= { envMgtSystem 8 }
|
|
emsOutputRelayConfig OBJECT IDENTIFIER ::= { envMgtSystem 9 }
|
|
emsOutletConfig OBJECT IDENTIFIER ::= { envMgtSystem 10 }
|
|
emsSensorConfig OBJECT IDENTIFIER ::= { envMgtSystem 11 }
|
|
|
|
emsStatus OBJECT IDENTIFIER ::= { envMgtSystem 12 }
|
|
emsProbeStatus OBJECT IDENTIFIER ::= { envMgtSystem 13 }
|
|
emsInputContactStatus OBJECT IDENTIFIER ::= { envMgtSystem 14 }
|
|
emsOutputRelayStatus OBJECT IDENTIFIER ::= { envMgtSystem 15 }
|
|
emsOutletStatus OBJECT IDENTIFIER ::= { envMgtSystem 16 }
|
|
emsAlarmDeviceStatus OBJECT IDENTIFIER ::= { envMgtSystem 17 }
|
|
emsSensorStatus OBJECT IDENTIFIER ::= { envMgtSystem 18 }
|
|
|
|
memModules OBJECT IDENTIFIER ::= { modEnvMgr 1 }
|
|
memSensors OBJECT IDENTIFIER ::= { modEnvMgr 2 }
|
|
memInputs OBJECT IDENTIFIER ::= { modEnvMgr 3 }
|
|
memOutputs OBJECT IDENTIFIER ::= { modEnvMgr 4 }
|
|
memOutlets OBJECT IDENTIFIER ::= { modEnvMgr 5 }
|
|
memBeacons OBJECT IDENTIFIER ::= { modEnvMgr 6 }
|
|
|
|
nlIdent OBJECT IDENTIFIER ::= { netlock 1 }
|
|
nlStatus OBJECT IDENTIFIER ::= { netlock 2 }
|
|
|
|
airFM OBJECT IDENTIFIER ::= { airConditioners 1 }
|
|
airFMIdent OBJECT IDENTIFIER ::= { airFM 1 }
|
|
airFMStatus OBJECT IDENTIFIER ::= { airFM 2 }
|
|
airFMGroup OBJECT IDENTIFIER ::= { airFM 3 }
|
|
airFMSystem OBJECT IDENTIFIER ::= { airFM 4 }
|
|
airFMModule OBJECT IDENTIFIER ::= { airFM 5 }
|
|
airFMAlarms OBJECT IDENTIFIER ::= { airFM 6 }
|
|
|
|
airFMGroupSysRoles OBJECT IDENTIFIER ::= { airFMGroup 4 }
|
|
airFMGroupCfg OBJECT IDENTIFIER ::= { airFMGroup 5 }
|
|
airFMGroupLoadShare OBJECT IDENTIFIER ::= { airFMGroup 6 }
|
|
airFMGroupFailover OBJECT IDENTIFIER ::= { airFMGroup 7 }
|
|
|
|
airFMGroupFailoverSys OBJECT IDENTIFIER ::= { airFMGroupFailover 1 }
|
|
airFMGroupFailoverMod OBJECT IDENTIFIER ::= { airFMGroupFailover 2 }
|
|
|
|
airFMSysStatus OBJECT IDENTIFIER ::= { airFMSystem 1 }
|
|
airFMSysDemands OBJECT IDENTIFIER ::= { airFMSystem 2 }
|
|
airFMSysSetup OBJECT IDENTIFIER ::= { airFMSystem 3 }
|
|
airFMSysConfig OBJECT IDENTIFIER ::= { airFMSystem 4 }
|
|
airFMSysCooling OBJECT IDENTIFIER ::= { airFMSystem 5 }
|
|
airFMSysHumidify OBJECT IDENTIFIER ::= { airFMSystem 6 }
|
|
airFMSysDehumidify OBJECT IDENTIFIER ::= { airFMSystem 7 }
|
|
airFMSysReheat OBJECT IDENTIFIER ::= { airFMSystem 8 }
|
|
airFMSysThresholds OBJECT IDENTIFIER ::= { airFMSystem 9 }
|
|
airFMSysInputs OBJECT IDENTIFIER ::= { airFMSystem 10 }
|
|
airFMSysOutputs OBJECT IDENTIFIER ::= { airFMSystem 11 }
|
|
airFMSysAlarmMap OBJECT IDENTIFIER ::= { airFMSystem 12 }
|
|
|
|
airFMSysAlarmMapSys OBJECT IDENTIFIER ::= { airFMSysAlarmMap 1 }
|
|
airFMSysAlarmMapMainMod OBJECT IDENTIFIER ::= { airFMSysAlarmMap 2 }
|
|
airFMSysAlarmMapExpMod1 OBJECT IDENTIFIER ::= { airFMSysAlarmMap 3 }
|
|
airFMSysAlarmMapExpMod2 OBJECT IDENTIFIER ::= { airFMSysAlarmMap 4 }
|
|
airFMSysAlarmMapInput OBJECT IDENTIFIER ::= { airFMSysAlarmMap 5 }
|
|
airFMSysAlarmMapOutput OBJECT IDENTIFIER ::= { airFMSysAlarmMap 6 }
|
|
|
|
airFMModIdent OBJECT IDENTIFIER ::= { airFMModule 1 }
|
|
airFMModStatus OBJECT IDENTIFIER ::= { airFMModule 2 }
|
|
airFMModProperties OBJECT IDENTIFIER ::= { airFMModule 3 }
|
|
airFMModCooling OBJECT IDENTIFIER ::= { airFMModule 4 }
|
|
airFMModHumidity OBJECT IDENTIFIER ::= { airFMModule 5 }
|
|
airFMModBlower1 OBJECT IDENTIFIER ::= { airFMModule 6 }
|
|
airFMModBlower2 OBJECT IDENTIFIER ::= { airFMModule 7 }
|
|
airFMModRunHours OBJECT IDENTIFIER ::= { airFMModule 8 }
|
|
airFMModServIntervals OBJECT IDENTIFIER ::= { airFMModule 9 }
|
|
airFMModServIntResets OBJECT IDENTIFIER ::= { airFMModule 10 }
|
|
|
|
|
|
airPA OBJECT IDENTIFIER ::= { airConditioners 2 }
|
|
airPAIdent OBJECT IDENTIFIER ::= { airPA 1 }
|
|
airPAStatus OBJECT IDENTIFIER ::= { airPA 2 }
|
|
|
|
airIR OBJECT IDENTIFIER ::= { airConditioners 3 }
|
|
airIRAlarms OBJECT IDENTIFIER ::= { airIR 1 }
|
|
airIRRC OBJECT IDENTIFIER ::= { airIR 2 }
|
|
airIRRP OBJECT IDENTIFIER ::= { airIR 3 }
|
|
airIRSC OBJECT IDENTIFIER ::= { airIR 4 }
|
|
|
|
airIRRCGroup OBJECT IDENTIFIER ::= { airIRRC 1 }
|
|
airIRRCUnit OBJECT IDENTIFIER ::= { airIRRC 2 }
|
|
|
|
airIRRCGroupStatus OBJECT IDENTIFIER ::= { airIRRCGroup 1 }
|
|
airIRRCGroupSetpoints OBJECT IDENTIFIER ::= { airIRRCGroup 2 }
|
|
airIRRCGroupConfig OBJECT IDENTIFIER ::= { airIRRCGroup 3 }
|
|
|
|
airIRRCUnitIdent OBJECT IDENTIFIER ::= { airIRRCUnit 1 }
|
|
airIRRCUnitStatus OBJECT IDENTIFIER ::= { airIRRCUnit 2 }
|
|
airIRRCUnitRunHours OBJECT IDENTIFIER ::= { airIRRCUnit 3 }
|
|
airIRRCUnitServiceIntervals OBJECT IDENTIFIER ::= { airIRRCUnit 4 }
|
|
airIRRCUnitThresholds OBJECT IDENTIFIER ::= { airIRRCUnit 5 }
|
|
airIRRCUnitConfig OBJECT IDENTIFIER ::= { airIRRCUnit 6 }
|
|
|
|
-- Series 100 DX Air Conditioners
|
|
airIRRP100 OBJECT IDENTIFIER ::= { airIRRP 1 }
|
|
-- Series 500 CW Air Conditioners
|
|
airIRRP500 OBJECT IDENTIFIER ::= { airIRRP 2 }
|
|
|
|
airIRRP100Group OBJECT IDENTIFIER ::= { airIRRP100 1 }
|
|
airIRRP100Unit OBJECT IDENTIFIER ::= { airIRRP100 2 }
|
|
|
|
airIRRP100GroupStatus OBJECT IDENTIFIER ::= { airIRRP100Group 1 }
|
|
airIRRP100GroupSetpoints OBJECT IDENTIFIER ::= { airIRRP100Group 2 }
|
|
airIRRP100GroupConfig OBJECT IDENTIFIER ::= { airIRRP100Group 3 }
|
|
|
|
airIRRP100UnitIdent OBJECT IDENTIFIER ::= { airIRRP100Unit 1 }
|
|
airIRRP100UnitStatus OBJECT IDENTIFIER ::= { airIRRP100Unit 2 }
|
|
airIRRP100UnitRunHours OBJECT IDENTIFIER ::= { airIRRP100Unit 3 }
|
|
airIRRP100UnitServiceIntervals OBJECT IDENTIFIER ::= { airIRRP100Unit 4 }
|
|
airIRRP100UnitThresholds OBJECT IDENTIFIER ::= { airIRRP100Unit 5 }
|
|
airIRRP100UnitConfig OBJECT IDENTIFIER ::= { airIRRP100Unit 6 }
|
|
|
|
airIRRP500Group OBJECT IDENTIFIER ::= { airIRRP500 1 }
|
|
airIRRP500Unit OBJECT IDENTIFIER ::= { airIRRP500 2 }
|
|
|
|
airIRRP500GroupStatus OBJECT IDENTIFIER ::= { airIRRP500Group 1 }
|
|
airIRRP500GroupSetpoints OBJECT IDENTIFIER ::= { airIRRP500Group 2 }
|
|
airIRRP500GroupConfig OBJECT IDENTIFIER ::= { airIRRP500Group 3 }
|
|
|
|
airIRRP500UnitIdent OBJECT IDENTIFIER ::= { airIRRP500Unit 1 }
|
|
airIRRP500UnitStatus OBJECT IDENTIFIER ::= { airIRRP500Unit 2 }
|
|
airIRRP500UnitRunHours OBJECT IDENTIFIER ::= { airIRRP500Unit 3 }
|
|
airIRRP500UnitServiceIntervals OBJECT IDENTIFIER ::= { airIRRP500Unit 4 }
|
|
airIRRP500UnitThresholds OBJECT IDENTIFIER ::= { airIRRP500Unit 5 }
|
|
airIRRP500UnitConfig OBJECT IDENTIFIER ::= { airIRRP500Unit 6 }
|
|
|
|
|
|
airIRSCUnit OBJECT IDENTIFIER ::= { airIRSC 1 }
|
|
|
|
airIRSCUnitIdent OBJECT IDENTIFIER ::= { airIRSCUnit 1 }
|
|
airIRSCUnitStatus OBJECT IDENTIFIER ::= { airIRSCUnit 2 }
|
|
airIRSCUnitRunHours OBJECT IDENTIFIER ::= { airIRSCUnit 3 }
|
|
airIRSCUnitServiceIntervals OBJECT IDENTIFIER ::= { airIRSCUnit 4 }
|
|
airIRSCUnitThresholds OBJECT IDENTIFIER ::= { airIRSCUnit 5 }
|
|
airIRSCUnitSetpoints OBJECT IDENTIFIER ::= { airIRSCUnit 6 }
|
|
airIRSCUnitConfig OBJECT IDENTIFIER ::= { airIRSCUnit 7 }
|
|
|
|
airIRSCGroup OBJECT IDENTIFIER ::= { airIRSC 2 }
|
|
|
|
airIRSCGroupStatus OBJECT IDENTIFIER ::= { airIRSCGroup 1 }
|
|
airIRSCGroupSetpoints OBJECT IDENTIFIER ::= { airIRSCGroup 2 }
|
|
airIRSCGroupConfig OBJECT IDENTIFIER ::= { airIRSCGroup 3 }
|
|
|
|
|
|
airIRGen2 OBJECT IDENTIFIER ::= { airConditioners 4 }
|
|
|
|
airIRG2Ident OBJECT IDENTIFIER ::= { airIRGen2 1 }
|
|
airIRG2Group OBJECT IDENTIFIER ::= { airIRGen2 2 }
|
|
airIRG2Alarms OBJECT IDENTIFIER ::= { airIRGen2 3 }
|
|
airIRG2RC OBJECT IDENTIFIER ::= { airIRGen2 4 }
|
|
airIRG2RD OBJECT IDENTIFIER ::= { airIRGen2 5 }
|
|
airIRG2SC OBJECT IDENTIFIER ::= { airIRGen2 6 }
|
|
airIRG2RA OBJECT IDENTIFIER ::= { airIRGen2 7 }
|
|
|
|
-- airIR Gen2 Group data
|
|
airIRG2GroupStatus OBJECT IDENTIFIER ::= { airIRG2Group 1 }
|
|
airIRG2GroupSetpoints OBJECT IDENTIFIER ::= { airIRG2Group 2 }
|
|
airIRG2GroupConfig OBJECT IDENTIFIER ::= { airIRG2Group 3 }
|
|
|
|
-- airIR Gen2 RD Unit data
|
|
airIRG2RDType1 OBJECT IDENTIFIER ::= { airIRG2RD 1 }
|
|
airIRG2RDType2 OBJECT IDENTIFIER ::= { airIRG2RD 2 }
|
|
airIRG2RDT2Status OBJECT IDENTIFIER ::= { airIRG2RDType2 1 }
|
|
airIRG2RDT2RunHours OBJECT IDENTIFIER ::= { airIRG2RDType2 2 }
|
|
airIRG2RDT2ServiceIntervals OBJECT IDENTIFIER ::= { airIRG2RDType2 3 }
|
|
airIRG2RDT2Thresholds OBJECT IDENTIFIER ::= { airIRG2RDType2 4 }
|
|
airIRG2RDT2Setpoints OBJECT IDENTIFIER ::= { airIRG2RDType2 5 }
|
|
airIRG2RDT2Config OBJECT IDENTIFIER ::= { airIRG2RDType2 6 }
|
|
|
|
airInRoom OBJECT IDENTIFIER ::= { airConditioners 5 }
|
|
|
|
airIRmIdent OBJECT IDENTIFIER ::= { airInRoom 1 }
|
|
airIRmAlarms OBJECT IDENTIFIER ::= { airInRoom 2 }
|
|
airIRmPerimeter OBJECT IDENTIFIER ::= { airInRoom 3 }
|
|
|
|
airIRmPmCommon1 OBJECT IDENTIFIER ::= { airIRmPerimeter 2 }
|
|
airIRmPmCommon2 OBJECT IDENTIFIER ::= { airIRmPerimeter 3 }
|
|
airIRmPmCommon3 OBJECT IDENTIFIER ::= { airIRmPerimeter 4 }
|
|
airIRmPmCommon4 OBJECT IDENTIFIER ::= { airIRmPerimeter 5 }
|
|
airIRmPmCommon5 OBJECT IDENTIFIER ::= { airIRmPerimeter 6 }
|
|
airIRmPmCompressor1 OBJECT IDENTIFIER ::= { airIRmPerimeter 7 }
|
|
airIRmPmCompressor2 OBJECT IDENTIFIER ::= { airIRmPerimeter 8 }
|
|
airIRmPmSuctionValve1 OBJECT IDENTIFIER ::= { airIRmPerimeter 9 }
|
|
airIRmPmSuctionValve2 OBJECT IDENTIFIER ::= { airIRmPerimeter 10 }
|
|
airIRmPmEheating1 OBJECT IDENTIFIER ::= { airIRmPerimeter 11 }
|
|
airIRmPmEheating2 OBJECT IDENTIFIER ::= { airIRmPerimeter 12 }
|
|
airIRmPmEheating3 OBJECT IDENTIFIER ::= { airIRmPerimeter 13 }
|
|
airIRmPmEheating4 OBJECT IDENTIFIER ::= { airIRmPerimeter 14 }
|
|
airIRmPmGECWvalve OBJECT IDENTIFIER ::= { airIRmPerimeter 15 }
|
|
airIRmPmGvalve OBJECT IDENTIFIER ::= { airIRmPerimeter 16 }
|
|
airIRmPmDrycooler1 OBJECT IDENTIFIER ::= { airIRmPerimeter 17 }
|
|
airIRmPmDrycooler2 OBJECT IDENTIFIER ::= { airIRmPerimeter 18 }
|
|
airIRmPmDrycooler3 OBJECT IDENTIFIER ::= { airIRmPerimeter 19 }
|
|
airIRmPmDrycooler4 OBJECT IDENTIFIER ::= { airIRmPerimeter 20 }
|
|
airIRmPmPump1 OBJECT IDENTIFIER ::= { airIRmPerimeter 21 }
|
|
airIRmPmPump2 OBJECT IDENTIFIER ::= { airIRmPerimeter 22 }
|
|
airIRmPmPump3 OBJECT IDENTIFIER ::= { airIRmPerimeter 23 }
|
|
airIRmPmPump4 OBJECT IDENTIFIER ::= { airIRmPerimeter 24 }
|
|
airIRmPmHotgasHeating OBJECT IDENTIFIER ::= { airIRmPerimeter 25 }
|
|
airIRmPmPWWHeating OBJECT IDENTIFIER ::= { airIRmPerimeter 26 }
|
|
airIRmPmHumidifier1 OBJECT IDENTIFIER ::= { airIRmPerimeter 27 }
|
|
airIRmPmHumidifier2 OBJECT IDENTIFIER ::= { airIRmPerimeter 28 }
|
|
-- Skipping 29 and 30.
|
|
airIRmPmDehumidification OBJECT IDENTIFIER ::= { airIRmPerimeter 31 }
|
|
airIRmPmFan1 OBJECT IDENTIFIER ::= { airIRmPerimeter 32 }
|
|
airIRmPmFan2 OBJECT IDENTIFIER ::= { airIRmPerimeter 33 }
|
|
airIRmPmFan3 OBJECT IDENTIFIER ::= { airIRmPerimeter 34 }
|
|
airIRmPmLouver1 OBJECT IDENTIFIER ::= { airIRmPerimeter 35 }
|
|
airIRmPmLouver2 OBJECT IDENTIFIER ::= { airIRmPerimeter 36 }
|
|
airIRmPmLouver3 OBJECT IDENTIFIER ::= { airIRmPerimeter 37 }
|
|
airIRmPmAuxAlarm1 OBJECT IDENTIFIER ::= { airIRmPerimeter 38 }
|
|
airIRmPmAuxAlarm2 OBJECT IDENTIFIER ::= { airIRmPerimeter 39 }
|
|
airIRmPmAuxAlarm3 OBJECT IDENTIFIER ::= { airIRmPerimeter 40 }
|
|
airIRmPmAuxAlarm4 OBJECT IDENTIFIER ::= { airIRmPerimeter 41 }
|
|
airIRmPmAuxAlarm5 OBJECT IDENTIFIER ::= { airIRmPerimeter 42 }
|
|
airIRmPmAlarmBits OBJECT IDENTIFIER ::= { airIRmPerimeter 43 }
|
|
airIRmPmMyZone OBJECT IDENTIFIER ::= { airIRmPerimeter 44 }
|
|
airIRmPmGlobalZoneData OBJECT IDENTIFIER ::= { airIRmPerimeter 45 }
|
|
|
|
airIRGen3 OBJECT IDENTIFIER ::= { airConditioners 6 }
|
|
|
|
airIRG3Ident OBJECT IDENTIFIER ::= { airIRGen3 1 }
|
|
airIRG3Group OBJECT IDENTIFIER ::= { airIRGen3 2 }
|
|
airIRG3Alarms OBJECT IDENTIFIER ::= { airIRGen3 3 }
|
|
airIRG3RDU OBJECT IDENTIFIER ::= { airIRGen3 4 }
|
|
airIRG3CM OBJECT IDENTIFIER ::= { airIRGen3 5 }
|
|
|
|
|
|
rARUIdent OBJECT IDENTIFIER ::= { rARU 1 }
|
|
rARUConfig OBJECT IDENTIFIER ::= { rARU 2 }
|
|
rARUStatus OBJECT IDENTIFIER ::= { rARU 3 }
|
|
rARUFanStatus OBJECT IDENTIFIER ::= { rARU 4 }
|
|
rARUPower OBJECT IDENTIFIER ::= { rARU 5 }
|
|
rARUSensors OBJECT IDENTIFIER ::= { rARU 6 }
|
|
|
|
|
|
accessPX OBJECT IDENTIFIER ::= { accessControl 1 }
|
|
|
|
accessPXIdent OBJECT IDENTIFIER ::= { accessPX 1 }
|
|
accessPXConfig OBJECT IDENTIFIER ::= { accessPX 2 }
|
|
accessPXConfigFront OBJECT IDENTIFIER ::= { accessPX 3 }
|
|
accessPXStatusFront OBJECT IDENTIFIER ::= { accessPX 4 }
|
|
accessPXConfigRear OBJECT IDENTIFIER ::= { accessPX 5 }
|
|
accessPXStatusRear OBJECT IDENTIFIER ::= { accessPX 6 }
|
|
accessPXConfigBeacon OBJECT IDENTIFIER ::= { accessPX 7 }
|
|
accessPXStatusBeacon OBJECT IDENTIFIER ::= { accessPX 8 }
|
|
|
|
apcLocalDisplayIdent OBJECT IDENTIFIER ::= { apcLocalDisplay 1 }
|
|
apcLocalDisplayConfig OBJECT IDENTIFIER ::= { apcLocalDisplay 2 }
|
|
|
|
accPX OBJECT IDENTIFIER ::= { accControl 1 }
|
|
|
|
isxModularPduIdent OBJECT IDENTIFIER ::= { isxModularPdu 1 }
|
|
isxModularPduDevice OBJECT IDENTIFIER ::= { isxModularPdu 2 }
|
|
isxModularPduStatus OBJECT IDENTIFIER ::= { isxModularPdu 3 }
|
|
|
|
symmetraPx48kVA OBJECT IDENTIFIER ::= { symmetraPX 1 }
|
|
symmetraPx160kVA OBJECT IDENTIFIER ::= { symmetraPX 2 }
|
|
symmetraPx250kVA OBJECT IDENTIFIER ::= { symmetraPX 3 }
|
|
symmetraPx500kVA OBJECT IDENTIFIER ::= { symmetraPX 4 }
|
|
symmetraPx100kVA OBJECT IDENTIFIER ::= { symmetraPX 5 }
|
|
symmetraPxDisplay OBJECT IDENTIFIER ::= { symmetraPX 6 }
|
|
|
|
isx24ModuleHalfRackPdu OBJECT IDENTIFIER ::= { isxModDistribution 1 }
|
|
isx6ModuleRackPdu OBJECT IDENTIFIER ::= { isxModDistribution 2 }
|
|
|
|
isxModularDistInfo OBJECT IDENTIFIER ::= { isxModularDistribution 1 }
|
|
isxModularDistModules OBJECT IDENTIFIER ::= { isxModularDistribution 2 }
|
|
isxModularDistSubFeeds OBJECT IDENTIFIER ::= { isxModularDistribution 3 }
|
|
isxModularDistTotals OBJECT IDENTIFIER ::= { isxModularDistribution 4 }
|
|
|
|
isxModularDistSysVoltage OBJECT IDENTIFIER ::= { isxModularDistTotals 1 }
|
|
isxModularDistSysCurrent OBJECT IDENTIFIER ::= { isxModularDistTotals 2 }
|
|
isxModularDistSysPower OBJECT IDENTIFIER ::= { isxModularDistTotals 3 }
|
|
|
|
isxcBasic OBJECT IDENTIFIER ::= { isxServers 1 }
|
|
isxcStandard OBJECT IDENTIFIER ::= { isxServers 2 }
|
|
isxcEnterprise OBJECT IDENTIFIER ::= { isxServers 3 }
|
|
isxcVirtual OBJECT IDENTIFIER ::= { isxServers 4 }
|
|
|
|
uioSensor OBJECT IDENTIFIER ::= { universalInputOutput 1 }
|
|
uioInputContact OBJECT IDENTIFIER ::= { universalInputOutput 2 }
|
|
uioOutputRelay OBJECT IDENTIFIER ::= { universalInputOutput 3 }
|
|
|
|
|
|
-- object types
|
|
|
|
-- the products group
|
|
-- the experimental group
|
|
|
|
|
|
|
|
-- the apcmgmt group
|
|
-- the mconfig group
|
|
|
|
mconfigNumTrapReceivers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of managers to send traps to."
|
|
::= { mconfig 1 }
|
|
|
|
mconfigTrapReceiverTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MconfigTrapReceiverEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of managers to send traps to. The number of
|
|
entries is given by the value of mconfigNumTrapReceivers."
|
|
::= { mconfig 2 }
|
|
|
|
mconfigTrapReceiverEntry OBJECT-TYPE
|
|
SYNTAX MconfigTrapReceiverEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The managers to send traps to."
|
|
INDEX { trapIndex}
|
|
::= { mconfigTrapReceiverTable 1 }
|
|
|
|
MconfigTrapReceiverEntry ::=
|
|
SEQUENCE {
|
|
trapIndex
|
|
INTEGER,
|
|
receiverAddr
|
|
IpAddress,
|
|
communityString
|
|
DisplayString,
|
|
severity
|
|
INTEGER,
|
|
acceptThisReceiver
|
|
INTEGER,
|
|
receiveTrapType
|
|
INTEGER
|
|
}
|
|
|
|
trapIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to a trap receiver entry."
|
|
::= { mconfigTrapReceiverEntry 1 }
|
|
|
|
receiverAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the manager to send a trap to."
|
|
::= { mconfigTrapReceiverEntry 2 }
|
|
|
|
communityString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The community name to use in the trap when
|
|
sent to the manager."
|
|
::= { mconfigTrapReceiverEntry 3 }
|
|
|
|
severity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
information(1),
|
|
warning(2),
|
|
severe(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The severity threshold of traps to send to the manager.
|
|
traps are labeled in severity as informational(1), warning(2),
|
|
severe(3). Only traps of equal or greater severity than
|
|
this value are sent to the manager."
|
|
::= { mconfigTrapReceiverEntry 4 }
|
|
|
|
acceptThisReceiver OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of yes(1) indicates that trap generation for this manager is enabled.
|
|
The value of no(2) indicates that trap generation for this manager is disabled"
|
|
::= { mconfigTrapReceiverEntry 5 }
|
|
|
|
|
|
receiveTrapType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powernet (1),
|
|
ietf (2),
|
|
both (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Type of trap."
|
|
::= { mconfigTrapReceiverEntry 6 }
|
|
|
|
mconfigBOOTPEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of yes(1) indicates the PowerNet Adapter is configured to
|
|
obtain its IP configuration parameters from a BOOTP server.
|
|
|
|
The value of no(2) indicates adapter will assume IP configuration parameters
|
|
values saved in adapter's eeprom, which was originally configured at local
|
|
console."
|
|
::= { mconfig 3 }
|
|
|
|
mconfigTFTPServerIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of TFTP server. If mconfigBOOTPEnabled is yes(1), then this IP address
|
|
is provided by BOOTP server and not allowed to be modified; otherwise, this IP address
|
|
can be modified.
|
|
|
|
Before using TFTP to load new code image, the image file should be placed in proper
|
|
directory of the specified TFTP server. This OID is only supported by APC Network
|
|
Management Cards."
|
|
::= { mconfig 4 }
|
|
|
|
newCodeAuthentViaTFTP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
validNewAgentCodeImage (2),
|
|
sameAgentCodeImage (3),
|
|
invalidAgentCodeImage (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Once mcontrolRestartAgent is set to loadAndExecuteNewAgent (3), PowerNet adapter will
|
|
start to load the remote image file, for authentication only, instead of saving the code
|
|
into flash memory. Only if a validNewAgentCodeImage (1) is found will the agent reboot
|
|
the PowerNet adapter and invoke the loader to load and save new code into the flash memory.
|
|
Otherwise, the current agent code will continue to run.
|
|
|
|
This OID shows the result of the above authentication process.
|
|
validNewAgentCodeImage (1) means the code image on TFTP server
|
|
is a valid APC agent code and is different version from the current agent.
|
|
Once agent identifies this, loader will start to update flash memory with
|
|
the new agent code.
|
|
|
|
sameAgentCodeImage (2) means the code image on TFTP server is exactly the
|
|
same as the currently running agent. Currently running agent will not invoke
|
|
loader to load the same again.
|
|
|
|
invalidAgentCodeImage (3) means the code image on TFTP server is NOT a valid
|
|
APC agent code. Thus, current agent will not load it into the flash memory.
|
|
|
|
The value of this OID will be associated with TRAP codeImageAuthentDone.
|
|
This OID is only supported by APC Network Management Cards."
|
|
|
|
::= { mconfig 5 }
|
|
|
|
mconfigClockDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current date in the mm/dd/yyyy format. Example: 01/01/2000."
|
|
::= { mconfigClock 1 }
|
|
|
|
mconfigClockTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current time in the hh:mm:ss am/pm format. Example: 12:00:00 am."
|
|
::= { mconfigClock 2 }
|
|
|
|
mcontrolRestartAgent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
restartCurrentAgent (1),
|
|
continueCurrentAgent (2),
|
|
loadAndExecuteNewAgent (3),
|
|
restartWithoutAgent (4),
|
|
resetNetworkAndRestart (5),
|
|
resetNetworkLeaveModeAndRestart (6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to restartCurrentAgent (1) will restart the same SNMP
|
|
agent code currently saved in flash memory. Setting this OID to
|
|
loadAndExecuteNewAgent (3) will enable adapter to load a new agent code
|
|
into the flash memory and start to execute this new agent code.
|
|
Bootp/tftp is the default protocol. loadAndExecuteNewAgent is only
|
|
supported by APC Network Management Cards. Setting
|
|
this OID to restartWithoutAgent (4) will restart the system and not
|
|
start the agent. The subsequent time the system restarts the agent will
|
|
also automatically restart. Setting this OID to
|
|
resetNetworkAndRestart (5) will set the Boot Mode, IP Address, Subnet
|
|
Mask, and Default Gateway to defaults, expire any existing DHCP lease
|
|
and then restart the system. Setting this OID to
|
|
resetNetworkLeaveModeAndRestart (6) will leave the Boot Mode at the
|
|
current setting, set the IP Address, Subnet Mask, and Default Gateway to
|
|
defaults, expire any existing DHCP lease and then restart the system."
|
|
|
|
::= { mcontrol 1 }
|
|
|
|
-- The mtrapargs group
|
|
-- These OIDs allows APC traps to be sent with additional arguments
|
|
-- which may not be defined in the APC MIB.
|
|
|
|
mtrapargsInteger OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an integer argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0."
|
|
::= { mtrapargs 1 }
|
|
|
|
mtrapargsIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an IP address argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0.0.0.0."
|
|
::= { mtrapargs 2 }
|
|
|
|
mtrapargsString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 3 }
|
|
|
|
mtrapargsGauge OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with a Gauge argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0."
|
|
::= { mtrapargs 4 }
|
|
|
|
mtrapargsTimeTicks OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with a TimeTicks argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0."
|
|
::= { mtrapargs 5 }
|
|
|
|
mtrapargsInteger02 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an integer argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0."
|
|
::= { mtrapargs 6 }
|
|
|
|
mtrapargsInteger03 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an integer argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0."
|
|
::= { mtrapargs 7 }
|
|
|
|
mtrapargsIpAddress02 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an IP address argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0.0.0.0."
|
|
::= { mtrapargs 8 }
|
|
|
|
mtrapargsIpAddress03 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an IP address argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0.0.0.0."
|
|
::= { mtrapargs 9 }
|
|
|
|
mtrapargsString02 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 10 }
|
|
|
|
mtrapargsString03 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 11 }
|
|
|
|
mtrapargsGauge02 OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with a Gauge argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0."
|
|
::= { mtrapargs 12 }
|
|
|
|
mtrapargsGauge03 OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with a Gauge argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0."
|
|
::= { mtrapargs 13 }
|
|
|
|
mtrapargsTimeTicks02 OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with a TimeTicks argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0."
|
|
::= { mtrapargs 14 }
|
|
|
|
mtrapargsTimeTicks03 OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with a TimeTicks argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0."
|
|
::= { mtrapargs 15 }
|
|
|
|
mtrapargsString04 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 16 }
|
|
|
|
mtrapargsString05 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 17 }
|
|
|
|
mtrapargsInteger04 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an integer argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0."
|
|
::= { mtrapargs 18 }
|
|
|
|
mtrapargsInteger05 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an integer argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return 0."
|
|
::= { mtrapargs 19 }
|
|
|
|
mtrapargsString06 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 20 }
|
|
|
|
mtrapargsString07 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 21 }
|
|
|
|
mtrapargsString08 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 22 }
|
|
|
|
mtrapargsOctetString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 23 }
|
|
|
|
mtrapargsOctetString02 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 24 }
|
|
|
|
mtrapargsOctetString03 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 25 }
|
|
|
|
mtrapargsOctetString04 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 26 }
|
|
|
|
mtrapargsOctetString05 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 27 }
|
|
|
|
mtrapargsOctetString06 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 28 }
|
|
|
|
mtrapargsOctetString07 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 29 }
|
|
|
|
mtrapargsOctetString08 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows APC traps to be sent with an octet string argument
|
|
that my not be defined in the APC MIB.
|
|
|
|
A get of this OID will return a NULL string."
|
|
::= { mtrapargs 30 }
|
|
|
|
-- the mfiletransfer group
|
|
-- the mfiletransferStatus group
|
|
mfiletransferStatusLastTransferResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lastFileTransferResultSuccessful (1),
|
|
lastFileTransferResultNotAvailable (2),
|
|
lastFileTransferResultFailureUnknown (3),
|
|
lastFileTransferResultFailureServerInaccessible (4),
|
|
lastFileTransferResultFailureServerAccessDenied (5),
|
|
lastFileTransferResultFailureFileNotFound (6),
|
|
lastFileTransferResultFailureFileTypeUnknown (7),
|
|
lastFileTransferResultFailureFileCorrupted (8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This OID has been deprecated.
|
|
|
|
Once mfiletransferControlInitiateFileTransfer is set to a value other than doNotInitiateFileTransfer
|
|
a file transfer of mfiletransferConfigSettingsFilename will be attempted from either a TFTP or FTP
|
|
server.
|
|
|
|
This OID shows the last attempted file transfer result.
|
|
lastFileTransferResultSuccessful (1) means the file transfer was successful.
|
|
lastFileTransferResultNotAvailable (2) means that there have been no previous file transfers.
|
|
lastFileTransferResultFailureUnknown (3) means that the last file transfer failed for an unknown reason.
|
|
lastFileTransferResultFailureServerInaccessible (4) means that the TFTP or FTP server could not be found on the network.
|
|
lastFileTransferResultFailureServerAccessDenied (5) means that the TFTP or FTP server denied access.
|
|
lastFileTransferResultFailureFileNotFound (6) means that the file could not be located.
|
|
lastFileTransferResultFailureFileTypeUnknown (7) means the file was examined, but the contents were unknown.
|
|
lastFileTransferResultFailureFileCorrupt (8) means the transferred file was corrupt."
|
|
|
|
::= { mfiletransferStatus 1 }
|
|
|
|
-- the mfiletransferConfig group
|
|
-- the mfiletransferConfigSettings group
|
|
|
|
mfiletransferConfigSettingsFilename OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This OID has been deprecated.
|
|
|
|
The path and name of the file to transfer using the mfiletransferControlInitiateFileTransfer OID.
|
|
If the file to transfer exists in the default server directory then the path may be omitted."
|
|
|
|
::= { mfiletransferConfigSettings 1 }
|
|
|
|
-- the mfiletransferConfigTFTP group
|
|
|
|
mfiletransferConfigTFTPServerAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This OID has been deprecated.
|
|
|
|
The IP Address in dotted decimal notation of the TFTP server involved in the file transfer."
|
|
|
|
::= { mfiletransferConfigTFTP 1 }
|
|
|
|
-- the mfiletransferConfigFTP group
|
|
|
|
mfiletransferConfigFTPServerAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This OID has been deprecated.
|
|
|
|
The IP Address in dotted decimal notation of the FTP server involved in the file transfer."
|
|
|
|
::= { mfiletransferConfigFTP 1 }
|
|
|
|
mfiletransferConfigFTPServerUser OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This OID has been deprecated.
|
|
|
|
The user identification for logging into the FTP server specified with mfiletransferConfigFTPServerAddress."
|
|
|
|
::= { mfiletransferConfigFTP 2 }
|
|
|
|
mfiletransferConfigFTPServerPassword OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This OID has been deprecated.
|
|
|
|
The password for logging into the FTP server specified with mfiletransferConfigFTPServerAddress."
|
|
|
|
::= { mfiletransferConfigFTP 3 }
|
|
|
|
-- the mfiletransferControl group
|
|
|
|
mfiletransferControlInitiateFileTransfer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
doNotInitiateFileTransfer (1),
|
|
initiateFileTransferDownloadViaTFTP (2),
|
|
initiateFileTransferDownloadViaFTP (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This OID has been deprecated.
|
|
|
|
Setting this OID to doNotInitiateFileTransfer (1) will do nothing.
|
|
|
|
Setting this OID to initiateFileTransferDownloadViaTFTP (2) will attempt to transfer the file named in
|
|
mfiletransferConfigSettingsFilename from the TFTP Server identified in mfiletransferConfigTFTPAddress.
|
|
|
|
Setting this OID to initiateFileTransferDownloadViaFTP (3) will attempt to transfer the file named in
|
|
mfiletransferConfigSettingsFilename from the FTP Server identified in mfiletransferConfigFTPAddress
|
|
using mfiletransferConfigFTPUser and mfiletransferConfigFTPPassword for the FTP Server login process."
|
|
|
|
::= { mfiletransferControl 1 }
|
|
-- the battManIdent group
|
|
|
|
battManIdentProductName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the battery manager."
|
|
::= { battManIdent 1 }
|
|
|
|
battManIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery manager network interface hardware revision.
|
|
This value is set at the factory."
|
|
::= { battManIdent 2 }
|
|
|
|
battManIdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery manager network interface firmware revision.
|
|
This value is set at the factory and can change with firmware update."
|
|
::= { battManIdent 3 }
|
|
|
|
battManIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date the battery manager was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory."
|
|
::= { battManIdent 4 }
|
|
|
|
battManIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery manager model number character string.
|
|
This value is set at the factory."
|
|
::= { battManIdent 5 }
|
|
|
|
battManIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery manager serial number character string.
|
|
This value is set at the factory."
|
|
::= { battManIdent 6 }
|
|
|
|
-- the battManCalib group
|
|
-- system calibration
|
|
|
|
battManOhmicValueCorrectionFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system ohmic value correction factor in percent."
|
|
::= { battManSystemCalib 1 }
|
|
|
|
-- unit calibration
|
|
|
|
battManUnitCalibTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManUnitCalibTable."
|
|
::= { battManUnitCalib 1 }
|
|
|
|
battManUnitCalibTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManUnitCalibEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting calibration information from each unit in the system."
|
|
::= { battManUnitCalib 2 }
|
|
|
|
battManUnitCalibEntry OBJECT-TYPE
|
|
SYNTAX BattManUnitCalibEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { battManUnitCalibIndex }
|
|
::= { battManUnitCalibTable 1 }
|
|
|
|
BattManUnitCalibEntry ::=
|
|
SEQUENCE {
|
|
battManUnitCalibIndex INTEGER,
|
|
battManUnitSerialNumber DisplayString,
|
|
battManBatteryVoltageZeroCalib INTEGER,
|
|
battManBatteryVoltageSpanCalib INTEGER
|
|
}
|
|
|
|
battManUnitCalibIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of unit calibration entries in the table."
|
|
::= { battManUnitCalibEntry 1 }
|
|
|
|
battManUnitSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the unit."
|
|
::= { battManUnitCalibEntry 2 }
|
|
|
|
battManBatteryVoltageZeroCalib OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit battery voltage zero calibration in millivolts."
|
|
::= { battManUnitCalibEntry 3 }
|
|
|
|
battManBatteryVoltageSpanCalib OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit battery voltage span calibration in hundredths of percent."
|
|
::= { battManUnitCalibEntry 4 }
|
|
|
|
-- string calibration table
|
|
|
|
battManStringCalibTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManStringCalibTable."
|
|
::= { battManStringCalib 1 }
|
|
|
|
battManStringCalibTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManStringCalibEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting calibration information from each string in the system."
|
|
::= { battManStringCalib 2 }
|
|
|
|
battManStringCalibEntry OBJECT-TYPE
|
|
SYNTAX BattManStringCalibEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManStringCalibIndex }
|
|
::= { battManStringCalibTable 1 }
|
|
|
|
BattManStringCalibEntry ::=
|
|
SEQUENCE {
|
|
battManStringCalibIndex INTEGER,
|
|
battManDCCurrentZeroCalib INTEGER,
|
|
battManACCurrentZeroCalib INTEGER,
|
|
battManProbeRange INTEGER
|
|
}
|
|
|
|
battManStringCalibIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of string calibration entries in the table."
|
|
::= { battManStringCalibEntry 1 }
|
|
|
|
battManDCCurrentZeroCalib OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string DC current zero calibration in tenths of amps."
|
|
::= { battManStringCalibEntry 2 }
|
|
|
|
battManACCurrentZeroCalib OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string AC current zero calibration in tenths of amps."
|
|
::= { battManStringCalibEntry 3 }
|
|
|
|
battManProbeRange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
amps1000 (1),
|
|
amps500 (2),
|
|
amps100 (3),
|
|
amps200 (4),
|
|
amps2000 (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string probe range in amps."
|
|
::= { battManStringCalibEntry 4 }
|
|
|
|
--string 1 battery calibration table
|
|
|
|
battManString1BatteryCalibTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString1BatteryCalibTable."
|
|
::= { battManBatteryCalib 1 }
|
|
|
|
battManString1BatteryCalibTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString1BatteryCalibEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting calibration information from each battery in String 1."
|
|
::= { battManBatteryCalib 2 }
|
|
|
|
battManString1BatteryCalibEntry OBJECT-TYPE
|
|
SYNTAX BattManString1BatteryCalibEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString1BatteryCalibIndex }
|
|
::= { battManString1BatteryCalibTable 1 }
|
|
|
|
BattManString1BatteryCalibEntry ::=
|
|
SEQUENCE {
|
|
battManString1BatteryCalibIndex INTEGER,
|
|
battManString1BatteryInterTierOhmicValue INTEGER
|
|
}
|
|
|
|
battManString1BatteryCalibIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of battery calibration entries in the table."
|
|
::= { battManString1BatteryCalibEntry 1 }
|
|
|
|
battManString1BatteryInterTierOhmicValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery inter-tier ohmic value in ohms. This corresponds to the ohmic
|
|
value for the positive terminal of the battery."
|
|
::= { battManString1BatteryCalibEntry 2 }
|
|
|
|
--string 2 battery calibration table
|
|
|
|
battManString2BatteryCalibTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString2BatteryCalibTable."
|
|
::= { battManBatteryCalib 3 }
|
|
|
|
battManString2BatteryCalibTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString2BatteryCalibEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting calibration information from each battery in String 2."
|
|
::= { battManBatteryCalib 4 }
|
|
|
|
battManString2BatteryCalibEntry OBJECT-TYPE
|
|
SYNTAX BattManString2BatteryCalibEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString2BatteryCalibIndex }
|
|
::= { battManString2BatteryCalibTable 1 }
|
|
|
|
BattManString2BatteryCalibEntry ::=
|
|
SEQUENCE {
|
|
battManString2BatteryCalibIndex INTEGER,
|
|
battManString2BatteryInterTierOhmicValue INTEGER
|
|
}
|
|
|
|
battManString2BatteryCalibIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of battery calibration entries in the table."
|
|
::= { battManString2BatteryCalibEntry 1 }
|
|
|
|
battManString2BatteryInterTierOhmicValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery inter-tier ohmic value in ohms."
|
|
::= { battManString2BatteryCalibEntry 2 }
|
|
|
|
-- the battManConfig group
|
|
|
|
battManConfigApplication OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
silcon (1),
|
|
other (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This OID has been deprecated."
|
|
::= { battManConfig 1 }
|
|
|
|
battManConfigBatteryChemistry OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
leadAcid (1),
|
|
nickel-Cadmium (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery chemistry of the monitored batteries:
|
|
LeadAcid(1) Lead Acid or
|
|
Nickel-Cadmium(2) Nickel-Cadmium."
|
|
::= { battManConfig 2 }
|
|
|
|
battManConfigBatteryAHCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amp hour capacity of the monitored batteries 5-4000 AH."
|
|
::= { battManConfig 3 }
|
|
|
|
battManConfigNumberofStrings OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of strings in the battery manager system."
|
|
::= { battManConfig 4 }
|
|
|
|
battManConfigBatteriesperString OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of batteries per string."
|
|
::= { battManConfig 5 }
|
|
|
|
|
|
battManConfigCellsperBattery OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oneCell (1),
|
|
twoCells (2),
|
|
fourCells (4),
|
|
sixCells (6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of cells per battery (1, 2, 4 or 6 for lead-acid, 1 or 2 for NiCd."
|
|
::= { battManConfig 6 }
|
|
|
|
|
|
battManConfigMinCellVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum battery cell voltage alarm limit in millivolts DC."
|
|
::= { battManConfig 7 }
|
|
|
|
battManConfigMaxCellVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum battery cell voltage alarm limit in millivolts DC."
|
|
::= { battManConfig 8 }
|
|
|
|
battManConfigMaxPilotTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum pilot battery temperature alarm limit in tenths of degrees Fahrenheit."
|
|
::= { battManConfig 9 }
|
|
|
|
battManConfigMaxPilotTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum pilot battery temperature alarm limit in tenths of degrees Celsius."
|
|
::= { battManConfig 10 }
|
|
|
|
battManConfigMaxAmbientTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum ambient temperature alarm limit in tenths of degrees Fahrenheit."
|
|
::= { battManConfig 11 }
|
|
|
|
battManConfigMaxAmbientTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum ambient temperature alarm limit in tenths of degrees Celsius."
|
|
::= { battManConfig 12 }
|
|
|
|
battManConfigMinAmbientTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Minimum Ambient Temperature alarm limit in tenths of degrees Fahrenheit."
|
|
::= { battManConfig 13 }
|
|
|
|
battManConfigMinAmbientTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Minimum Ambient Temperature alarm limit in tenths of degrees Celsius."
|
|
::= { battManConfig 14 }
|
|
|
|
battManConfigMaxRippleCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum ripple current alarm limit for the monitored battery
|
|
strings in percent of AH capacity."
|
|
::= { battManConfig 15 }
|
|
|
|
battManConfigMaxCurrentAcceptanceDeviation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum current acceptance deviation alarm limit in percent."
|
|
::= { battManConfig 16 }
|
|
|
|
battManConfigMonitorWireLength OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fiftyFeetOrLess (1),
|
|
moreThanFiftyFeet (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The monitor wire length:
|
|
fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet.
|
|
moreThanFiftyFeet (2) indicates that the wire length is greater than 50 feet."
|
|
::= { battManConfig 17 }
|
|
|
|
battManConfigDischargeVoltageAlarmLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The discharge voltage alarm level in percent."
|
|
::= { battManConfig 18 }
|
|
|
|
battManConfigAutoAnnunciatorReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The annunciator output signal reset method:
|
|
disabled(1) means the annunciator signal output will be reset when the reset button is pressed.
|
|
enabled(2) means the annunciator will stop signaling when all alarm conditions clear."
|
|
::= { battManConfig 19 }
|
|
|
|
battManConfigSuspendCellVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is used along with the number of cells per battery
|
|
and the number of batteries per string to determine if
|
|
a battery string has violated the low voltage limit. If
|
|
so, the Battery Management System will enter suspend mode.
|
|
Measured in millivolts DC"
|
|
::= { battManConfig 20 }
|
|
|
|
battManConfigOhmicTestWaitTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time in seconds after a discharge event before
|
|
data will be collected for the ohmic value calculation."
|
|
::= { battManConfig 21 }
|
|
|
|
battManConfigNumberOfBoosts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of consecutive times the Battery Management
|
|
System applies a charge to each battery during a boost
|
|
cycle. Batteries with a Rated Battery AH Capacity
|
|
less than or equal to 120 AH will always have a value
|
|
of one for Number of Boosts."
|
|
::= { battManConfig 22 }
|
|
|
|
-- the battManAlarm group
|
|
|
|
battManAlarmManagementController OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Management Controller Alarm is :
|
|
normal(1) no alarm conditions identified
|
|
alarm(2) an alarm condition exists."
|
|
::= { battManAlarm 1 }
|
|
|
|
battManAlarmBatteries OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Batteries Alarm is :
|
|
normal(1) no alarm conditions identified
|
|
alarm(2) an alarm condition exists."
|
|
::= { battManAlarm 2 }
|
|
|
|
battManAlarmCharger OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Charger Alarm is :
|
|
normal(1) no alarm conditions identified
|
|
alarm(2) an alarm condition exists."
|
|
::= { battManAlarm 3 }
|
|
|
|
battManAlarmEnvironment OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Environment Alarm is :
|
|
normal(1) no alarm conditions identified
|
|
alarm(2) an alarm condition exists."
|
|
::= { battManAlarm 4 }
|
|
|
|
-- the battManSystemStatus group
|
|
|
|
-- These are system wide parameters
|
|
|
|
battManSystemAmbientTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system ambient temperature in tenths of degrees Celsius."
|
|
::= { battManSystemStatus 1 }
|
|
|
|
battManSystemAmbientTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system ambient temperature in tenths of degrees Fahrenheit."
|
|
::= { battManSystemStatus 2 }
|
|
|
|
battManSystemPilotTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system pilot temperature in tenths of degrees Celsius."
|
|
::= { battManSystemStatus 3 }
|
|
|
|
battManSystemPilotTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system pilot temperature in tenths of degrees Fahrenheit."
|
|
::= { battManSystemStatus 4 }
|
|
|
|
battManSystemAmbientHighTempAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the system has a high temperature alarm."
|
|
::= { battManSystemStatus 5 }
|
|
|
|
battManSystemAmbientLowTempAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the system has a low temperature alarm."
|
|
::= { battManSystemStatus 6 }
|
|
|
|
battManSystemPilotBatteryHighTempAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the system has a pilot battery high temperature alarm."
|
|
::= { battManSystemStatus 7 }
|
|
|
|
battManSystemPilotProbeDisconnected OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the system pilot probe is disconnected."
|
|
::= { battManSystemStatus 8 }
|
|
|
|
battManSystemAmbientProbeDisconnected OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the system ambient probe is disconnected."
|
|
::= { battManSystemStatus 9 }
|
|
|
|
battManSystemConfigurationInvalid OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the system is not configured correctly."
|
|
::= { battManSystemStatus 10 }
|
|
|
|
battManSystemSuspendVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the system has suspended voltage scans."
|
|
::= { battManSystemStatus 11 }
|
|
|
|
-- This is a table of input contact parameters
|
|
|
|
battManInputContactTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManInputContactTable."
|
|
::= { battManInputContactStatus 1 }
|
|
|
|
battManInputContactTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManInputContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each contact
|
|
in the system. "
|
|
::= { battManInputContactStatus 2 }
|
|
|
|
battManInputContactEntry OBJECT-TYPE
|
|
SYNTAX BattManInputContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The contact to get data from."
|
|
INDEX { battManInputContactIndex }
|
|
::= { battManInputContactTable 1 }
|
|
|
|
BattManInputContactEntry ::=
|
|
SEQUENCE {
|
|
battManInputContactIndex INTEGER,
|
|
battManInputContactName DisplayString,
|
|
battManInputContactAlarmState INTEGER,
|
|
battManInputContactState INTEGER,
|
|
battManInputContactNormalState INTEGER,
|
|
battManInputContactAlarmDelay INTEGER
|
|
}
|
|
|
|
battManInputContactIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of contact entries in the table."
|
|
::= { battManInputContactEntry 1 }
|
|
|
|
battManInputContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the input contact."
|
|
::= { battManInputContactEntry 2 }
|
|
|
|
battManInputContactAlarmState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the alarm condition is active for this contact."
|
|
::= { battManInputContactEntry 3 }
|
|
|
|
battManInputContactState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to open(1), the input contact is in the open state.
|
|
When set to closed(2), the input contact is in the closed state."
|
|
::= { battManInputContactEntry 4 }
|
|
|
|
battManInputContactNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to open(1), the input contact is normally open.
|
|
When set to closed(2), the input contact is normally closed."
|
|
::= { battManInputContactEntry 5 }
|
|
|
|
battManInputContactAlarmDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input contact alarm delay time in seconds."
|
|
::= { battManInputContactEntry 6 }
|
|
|
|
-- This is a table of battery string parameters
|
|
|
|
battManStringTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManStringTable."
|
|
::= { battManStringStatus 1 }
|
|
|
|
battManStringTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManStringEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each string
|
|
in the system. "
|
|
::= { battManStringStatus 2 }
|
|
|
|
battManStringEntry OBJECT-TYPE
|
|
SYNTAX BattManStringEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManStringIndex }
|
|
::= { battManStringTable 1 }
|
|
|
|
BattManStringEntry ::=
|
|
SEQUENCE {
|
|
battManStringIndex INTEGER,
|
|
battManStringCurrent INTEGER,
|
|
battManStringRippleCurrent INTEGER,
|
|
battManStringChargerHighVoltageAlarm INTEGER,
|
|
battManStringChargerLowVoltageAlarm INTEGER,
|
|
battManStringCurrentProbeDisconnected INTEGER,
|
|
battManStringOnBattery INTEGER,
|
|
battManStringHighRippleCurrent INTEGER,
|
|
battManStringVoltage INTEGER,
|
|
battManStringDischargeLess5Seconds INTEGER,
|
|
battManStringDischarge5to10Seconds INTEGER,
|
|
battManStringDischarge10to60Seconds INTEGER,
|
|
battManStringDischargeMore60Seconds INTEGER
|
|
}
|
|
|
|
battManStringIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of string entries in the table."
|
|
::= { battManStringEntry 1 }
|
|
|
|
battManStringCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string current in tenths of amps."
|
|
::= { battManStringEntry 2 }
|
|
|
|
battManStringRippleCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string ripple current in tenths of amps."
|
|
::= { battManStringEntry 3 }
|
|
|
|
battManStringChargerHighVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the string charger has a high voltage alarm."
|
|
::= { battManStringEntry 4 }
|
|
|
|
battManStringChargerLowVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the string charger has a low voltage alarm."
|
|
::= { battManStringEntry 5 }
|
|
|
|
battManStringCurrentProbeDisconnected OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the string charger probe is disconnected."
|
|
::= { battManStringEntry 6 }
|
|
|
|
battManStringOnBattery OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the string is in the on-battery state."
|
|
::= { battManStringEntry 7 }
|
|
|
|
battManStringHighRippleCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that the string has a high ripple current."
|
|
::= { battManStringEntry 8 }
|
|
|
|
battManStringVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sum of the voltages for all of the batteries on a
|
|
string in millivolts DC."
|
|
::= { battManStringEntry 9 }
|
|
|
|
battManStringDischargeLess5Seconds OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of recorded discharges lasting less than
|
|
5 seconds."
|
|
::= { battManStringEntry 10 }
|
|
|
|
battManStringDischarge5to10Seconds OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of recorded discharges lasting between 5
|
|
and 10 seconds."
|
|
::= { battManStringEntry 11 }
|
|
|
|
battManStringDischarge10to60Seconds OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of recorded discharges lasting between 10
|
|
and 60 seconds."
|
|
::= { battManStringEntry 12 }
|
|
|
|
battManStringDischargeMore60Seconds OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of recorded discharges lasting more than
|
|
60 seconds (1 minute)."
|
|
::= { battManStringEntry 13 }
|
|
|
|
-- the battManString1BatteryStatus group
|
|
|
|
battManString1BatteryTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString1BatteryTable."
|
|
::= { battManBatteryStatus 1 }
|
|
|
|
battManString1BatteryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString1BatteryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each string
|
|
in the system. "
|
|
::= { battManBatteryStatus 2 }
|
|
|
|
battManString1BatteryEntry OBJECT-TYPE
|
|
SYNTAX BattManString1BatteryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString1BatteryIndex }
|
|
::= { battManString1BatteryTable 1 }
|
|
|
|
BattManString1BatteryEntry ::=
|
|
SEQUENCE {
|
|
battManString1BatteryIndex INTEGER,
|
|
battManString1BatteryVoltage INTEGER,
|
|
battManString1BatteryLowestVoltage INTEGER,
|
|
battManString1BatteryCellShorted INTEGER,
|
|
battManString1BatteryOpenFuseOrConnection INTEGER,
|
|
battManString1BatteryLowCapacity INTEGER,
|
|
battManString1BatteryHighOhmicValue INTEGER,
|
|
battManString1BatteryThermalRunaway INTEGER,
|
|
battManString1BatteryDryout INTEGER,
|
|
battManString1BatteryUserHighVoltageAlarm INTEGER,
|
|
battManString1BatteryUserLowVoltageAlarm INTEGER,
|
|
battManString1BatteryChemHighVoltageAlarm INTEGER,
|
|
battManString1BatteryChemLowVoltageAlarm INTEGER,
|
|
battManString1BatteryOpenCell INTEGER
|
|
}
|
|
|
|
battManString1BatteryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of string entries in the table."
|
|
::= { battManString1BatteryEntry 1 }
|
|
|
|
battManString1BatteryVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery voltage in millivolts DC."
|
|
::= { battManString1BatteryEntry 2 }
|
|
|
|
battManString1BatteryLowestVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The lowest battery discharge voltage during the last power event in millivolts DC."
|
|
::= { battManString1BatteryEntry 3 }
|
|
|
|
battManString1BatteryCellShorted OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that a battery cell is shorted."
|
|
::= { battManString1BatteryEntry 4 }
|
|
|
|
battManString1BatteryOpenFuseOrConnection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that a fuse or connection is open."
|
|
::= { battManString1BatteryEntry 5 }
|
|
|
|
battManString1BatteryLowCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has low capacity."
|
|
::= { battManString1BatteryEntry 6 }
|
|
|
|
battManString1BatteryHighOhmicValue OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has a high ohmic value."
|
|
::= { battManString1BatteryEntry 7 }
|
|
|
|
battManString1BatteryThermalRunaway OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has a thermal runaway condition."
|
|
::= { battManString1BatteryEntry 8 }
|
|
|
|
battManString1BatteryDryout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has a dryout condition."
|
|
::= { battManString1BatteryEntry 9 }
|
|
|
|
battManString1BatteryUserHighVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has violated
|
|
the user level high voltage limit."
|
|
::= { battManString1BatteryEntry 10 }
|
|
|
|
battManString1BatteryUserLowVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has violated
|
|
the user level low voltage limit."
|
|
::= { battManString1BatteryEntry 11 }
|
|
|
|
battManString1BatteryChemHighVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has violated
|
|
the chemistry level high voltage limit."
|
|
::= { battManString1BatteryEntry 12 }
|
|
|
|
battManString1BatteryChemLowVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has violated
|
|
the chemistry level low voltage limit."
|
|
::= { battManString1BatteryEntry 13 }
|
|
|
|
battManString1BatteryOpenCell OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates the battery has an open
|
|
cell or an inter-connection is abnormal."
|
|
::= { battManString1BatteryEntry 14 }
|
|
|
|
|
|
-- the battManString2BatteryStatus group
|
|
|
|
battManString2BatteryTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString2BatteryTable."
|
|
::= { battManBatteryStatus 3 }
|
|
|
|
battManString2BatteryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString2BatteryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each string
|
|
in the system. "
|
|
::= { battManBatteryStatus 4 }
|
|
|
|
battManString2BatteryEntry OBJECT-TYPE
|
|
SYNTAX BattManString2BatteryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString2BatteryIndex }
|
|
::= { battManString2BatteryTable 1 }
|
|
|
|
BattManString2BatteryEntry ::=
|
|
SEQUENCE {
|
|
battManString2BatteryIndex INTEGER,
|
|
battManString2BatteryVoltage INTEGER,
|
|
battManString2BatteryLowestVoltage INTEGER,
|
|
battManString2BatteryCellShorted INTEGER,
|
|
battManString2BatteryOpenFuseOrConnection INTEGER,
|
|
battManString2BatteryLowCapacity INTEGER,
|
|
battManString2BatteryHighOhmicValue INTEGER,
|
|
battManString2BatteryThermalRunaway INTEGER,
|
|
battManString2BatteryDryout INTEGER,
|
|
battManString2BatteryUserHighVoltageAlarm INTEGER,
|
|
battManString2BatteryUserLowVoltageAlarm INTEGER,
|
|
battManString2BatteryChemHighVoltageAlarm INTEGER,
|
|
battManString2BatteryChemLowVoltageAlarm INTEGER,
|
|
battManString2BatteryOpenCell INTEGER
|
|
}
|
|
|
|
battManString2BatteryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of string entries in the table."
|
|
::= { battManString2BatteryEntry 1 }
|
|
|
|
battManString2BatteryVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery voltage in millivolts DC."
|
|
::= { battManString2BatteryEntry 2 }
|
|
|
|
battManString2BatteryLowestVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The lowest battery discharge voltage during the last power event in millivolts DC."
|
|
::= { battManString2BatteryEntry 3 }
|
|
|
|
battManString2BatteryCellShorted OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that a battery cell is shorted."
|
|
::= { battManString2BatteryEntry 4 }
|
|
|
|
battManString2BatteryOpenFuseOrConnection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates that a fuse or connection is open."
|
|
::= { battManString2BatteryEntry 5 }
|
|
|
|
battManString2BatteryLowCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has low capacity."
|
|
::= { battManString2BatteryEntry 6 }
|
|
|
|
battManString2BatteryHighOhmicValue OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has a high ohmic value."
|
|
::= { battManString2BatteryEntry 7 }
|
|
|
|
battManString2BatteryThermalRunaway OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has a thermal runaway condition."
|
|
::= { battManString2BatteryEntry 8 }
|
|
|
|
battManString2BatteryDryout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has a dryout condition."
|
|
::= { battManString2BatteryEntry 9 }
|
|
|
|
battManString2BatteryUserHighVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has violated
|
|
the user level high voltage limit."
|
|
::= { battManString2BatteryEntry 10 }
|
|
|
|
battManString2BatteryUserLowVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has violated
|
|
the user level low voltage limit."
|
|
::= { battManString2BatteryEntry 11 }
|
|
|
|
battManString2BatteryChemHighVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has violated
|
|
the chemistry level high voltage limit."
|
|
::= { battManString2BatteryEntry 12 }
|
|
|
|
battManString2BatteryChemLowVoltageAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates a battery has violated
|
|
the chemistry level low voltage limit."
|
|
::= { battManString2BatteryEntry 13 }
|
|
|
|
battManString2BatteryOpenCell OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates the battery has an open
|
|
cell or an inter-connection is abnormal."
|
|
::= { battManString2BatteryEntry 14 }
|
|
|
|
-- battery manager control group
|
|
battManRemoteAnnunciatorReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset(2) will reset the user interface annunciator.
|
|
Getting this OID will do nothing and return the noOperation(1) value."
|
|
::= { battManControl 1 }
|
|
|
|
battManResetChargeCurrentDeviationBenchmark OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset(2) will reset the charge current deviation benchmark.
|
|
Getting this OID will do nothing and return the noOperation(1) value."
|
|
::= { battManControl 2 }
|
|
|
|
battManResetLowestDischargeVoltages OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset(2) will reset the lowest discharge voltages.
|
|
Getting this OID will do nothing and return the noOperation(1) value."
|
|
::= { battManControl 3 }
|
|
|
|
battManResetDischargeCounters OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset(2) will reset all discharge event counters.
|
|
Getting this OID will do nothing and return the noOperation(1) value."
|
|
::= { battManControl 4 }
|
|
|
|
-- the battManTestResults group
|
|
|
|
--string 1 test results table
|
|
|
|
battManString1OhmicValueLastDischargeInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Informational text showing the date/time, load, and pilot temperature for the string
|
|
during the last discharge when ohmic values were recorded."
|
|
::= { battManTestResults 1 }
|
|
|
|
battManString1OhmicValueTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString1OhmicValueTable."
|
|
::= { battManTestResults 2 }
|
|
|
|
battManString1OhmicValueTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString1OhmicValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting ohmic value information from each battery in String 1."
|
|
::= { battManTestResults 3 }
|
|
|
|
battManString1OhmicValueEntry OBJECT-TYPE
|
|
SYNTAX BattManString1OhmicValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString1OhmicValueIndex }
|
|
::= { battManString1OhmicValueTable 1 }
|
|
|
|
BattManString1OhmicValueEntry ::=
|
|
SEQUENCE {
|
|
battManString1OhmicValueIndex INTEGER,
|
|
battManString1OhmicValueData INTEGER
|
|
}
|
|
|
|
battManString1OhmicValueIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery number."
|
|
::= { battManString1OhmicValueEntry 1 }
|
|
|
|
battManString1OhmicValueData OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery inter-tier ohmic value in ohms.
|
|
Note: Zero or negative values are invalid and may indicate
|
|
faulty calibration of ohmic value correction factors."
|
|
::= { battManString1OhmicValueEntry 2 }
|
|
|
|
battManString1ResponseTestChangeTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString1ResponseTestChangeTable."
|
|
::= { battManTestResults 4 }
|
|
|
|
battManString1ResponseTestChangeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString1ResponseTestChangeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting response test change information from each battery in String 1."
|
|
::= { battManTestResults 5 }
|
|
|
|
battManString1ResponseTestChangeEntry OBJECT-TYPE
|
|
SYNTAX BattManString1ResponseTestChangeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString1ResponseTestChangeIndex }
|
|
::= { battManString1ResponseTestChangeTable 1 }
|
|
|
|
BattManString1ResponseTestChangeEntry ::=
|
|
SEQUENCE {
|
|
battManString1ResponseTestChangeIndex INTEGER,
|
|
battManString1ResponseTestChangeData INTEGER
|
|
}
|
|
|
|
battManString1ResponseTestChangeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of the entries in the table."
|
|
::= { battManString1ResponseTestChangeEntry 1 }
|
|
|
|
battManString1ResponseTestChangeData OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery response test change in percent."
|
|
::= { battManString1ResponseTestChangeEntry 2 }
|
|
|
|
battManString2OhmicValueLastDischargeInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Informational text showing the date/time, load, and pilot temperature for the string
|
|
during the last discharge when ohmic values were recorded."
|
|
::= { battManTestResults 6 }
|
|
|
|
battManString2OhmicValueTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString2OhmicValueTable."
|
|
::= { battManTestResults 7 }
|
|
|
|
battManString2OhmicValueTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString2OhmicValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting ohmic value information from each battery in String 2."
|
|
::= { battManTestResults 8 }
|
|
|
|
battManString2OhmicValueEntry OBJECT-TYPE
|
|
SYNTAX BattManString2OhmicValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString2OhmicValueIndex }
|
|
::= { battManString2OhmicValueTable 1 }
|
|
|
|
BattManString2OhmicValueEntry ::=
|
|
SEQUENCE {
|
|
battManString2OhmicValueIndex INTEGER,
|
|
battManString2OhmicValueData INTEGER
|
|
}
|
|
|
|
battManString2OhmicValueIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of battery calibration entries in the table."
|
|
::= { battManString2OhmicValueEntry 1 }
|
|
|
|
battManString2OhmicValueData OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery inter-tier ohmic value in ohms.
|
|
Note: Zero or negative values are invalid and may indicate
|
|
faulty calibration of ohmic value correction factors."
|
|
::= { battManString2OhmicValueEntry 2 }
|
|
|
|
battManString2ResponseTestChangeTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString2ResponseTestChangeTable."
|
|
::= { battManTestResults 9 }
|
|
|
|
battManString2ResponseTestChangeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString2ResponseTestChangeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting response test change information from each battery in String 2."
|
|
::= { battManTestResults 10 }
|
|
|
|
battManString2ResponseTestChangeEntry OBJECT-TYPE
|
|
SYNTAX BattManString2ResponseTestChangeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString2ResponseTestChangeIndex }
|
|
::= { battManString2ResponseTestChangeTable 1 }
|
|
|
|
BattManString2ResponseTestChangeEntry ::=
|
|
SEQUENCE {
|
|
battManString2ResponseTestChangeIndex INTEGER,
|
|
battManString2ResponseTestChangeData INTEGER
|
|
}
|
|
|
|
battManString2ResponseTestChangeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of the entries in the table."
|
|
::= { battManString2ResponseTestChangeEntry 1 }
|
|
|
|
battManString2ResponseTestChangeData OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery response test change in percent."
|
|
::= { battManString2ResponseTestChangeEntry 2 }
|
|
|
|
battManString1ResponseTestCurrentTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString1ResponseTestCurrentTable."
|
|
::= { battManTestResults 11 }
|
|
|
|
battManString1ResponseTestCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString1ResponseTestCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting response test current information from each battery
|
|
in String 1."
|
|
::= { battManTestResults 12 }
|
|
|
|
battManString1ResponseTestCurrentEntry OBJECT-TYPE
|
|
SYNTAX BattManString1ResponseTestCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString1ResponseTestCurrentIndex }
|
|
::= { battManString1ResponseTestCurrentTable 1 }
|
|
|
|
BattManString1ResponseTestCurrentEntry ::=
|
|
SEQUENCE {
|
|
battManString1ResponseTestCurrentIndex INTEGER,
|
|
battManString1ResponseTestCurrentData INTEGER
|
|
}
|
|
|
|
battManString1ResponseTestCurrentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of the entries in the table."
|
|
::= { battManString1ResponseTestCurrentEntry 1 }
|
|
|
|
battManString1ResponseTestCurrentData OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery response test current in milliamps."
|
|
::= { battManString1ResponseTestCurrentEntry 2 }
|
|
|
|
battManString2ResponseTestCurrentTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString2ResponseTestCurrentTable."
|
|
::= { battManTestResults 13 }
|
|
|
|
battManString2ResponseTestCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString2ResponseTestCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting response test current information from each battery
|
|
in String 2."
|
|
::= { battManTestResults 14 }
|
|
|
|
battManString2ResponseTestCurrentEntry OBJECT-TYPE
|
|
SYNTAX BattManString2ResponseTestCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString2ResponseTestCurrentIndex }
|
|
::= { battManString2ResponseTestCurrentTable 1 }
|
|
|
|
BattManString2ResponseTestCurrentEntry ::=
|
|
SEQUENCE {
|
|
battManString2ResponseTestCurrentIndex INTEGER,
|
|
battManString2ResponseTestCurrentData INTEGER
|
|
}
|
|
|
|
battManString2ResponseTestCurrentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of the entries in the table."
|
|
::= { battManString2ResponseTestCurrentEntry 1 }
|
|
|
|
battManString2ResponseTestCurrentData OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery response test current in milliamps."
|
|
::= { battManString2ResponseTestCurrentEntry 2 }
|
|
|
|
battManString1ResponseTestCurrentBenchmarkTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString1ResponseTestCurrentBenchmarkTable."
|
|
::= { battManTestResults 15 }
|
|
|
|
battManString1ResponseTestCurrentBenchmarkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString1ResponseTestCurrentBenchmarkEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting response test current benchmark information from
|
|
each battery in String 1."
|
|
::= { battManTestResults 16 }
|
|
|
|
battManString1ResponseTestCurrentBenchmarkEntry OBJECT-TYPE
|
|
SYNTAX BattManString1ResponseTestCurrentBenchmarkEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString1ResponseTestCurrentBenchmarkIndex }
|
|
::= { battManString1ResponseTestCurrentBenchmarkTable 1 }
|
|
|
|
BattManString1ResponseTestCurrentBenchmarkEntry ::=
|
|
SEQUENCE {
|
|
battManString1ResponseTestCurrentBenchmarkIndex INTEGER,
|
|
battManString1ResponseTestCurrentBenchmarkData INTEGER
|
|
}
|
|
|
|
battManString1ResponseTestCurrentBenchmarkIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of the entries in the table."
|
|
::= { battManString1ResponseTestCurrentBenchmarkEntry 1 }
|
|
|
|
battManString1ResponseTestCurrentBenchmarkData OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery response test current benchmark in milliamps."
|
|
::= { battManString1ResponseTestCurrentBenchmarkEntry 2 }
|
|
|
|
battManString2ResponseTestCurrentBenchmarkTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManString2ResponseTestCurrentBenchmarkTable."
|
|
::= { battManTestResults 17 }
|
|
|
|
battManString2ResponseTestCurrentBenchmarkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManString2ResponseTestCurrentBenchmarkEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting response test current benchmark information from
|
|
each battery in String 2."
|
|
::= { battManTestResults 18 }
|
|
|
|
battManString2ResponseTestCurrentBenchmarkEntry OBJECT-TYPE
|
|
SYNTAX BattManString2ResponseTestCurrentBenchmarkEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string to get data from."
|
|
INDEX { battManString2ResponseTestCurrentBenchmarkIndex }
|
|
::= { battManString2ResponseTestCurrentBenchmarkTable 1 }
|
|
|
|
BattManString2ResponseTestCurrentBenchmarkEntry ::=
|
|
SEQUENCE {
|
|
battManString2ResponseTestCurrentBenchmarkIndex INTEGER,
|
|
battManString2ResponseTestCurrentBenchmarkData INTEGER
|
|
}
|
|
|
|
battManString2ResponseTestCurrentBenchmarkIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of the entries in the table."
|
|
::= { battManString2ResponseTestCurrentBenchmarkEntry 1 }
|
|
|
|
battManString2ResponseTestCurrentBenchmarkData OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery response test current benchmark in milliamps."
|
|
::= { battManString2ResponseTestCurrentBenchmarkEntry 2 }
|
|
|
|
-- battManUnitStatus
|
|
|
|
battManUnitStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the battManUnitStatusTable."
|
|
::= { battManUnitStatus 1 }
|
|
|
|
battManUnitStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BattManUnitStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting status information from each unit in the system."
|
|
::= { battManUnitStatus 2 }
|
|
|
|
battManUnitStatusEntry OBJECT-TYPE
|
|
SYNTAX BattManUnitStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { battManUnitStatusIndex }
|
|
::= { battManUnitStatusTable 1 }
|
|
|
|
BattManUnitStatusEntry ::=
|
|
SEQUENCE {
|
|
battManUnitStatusIndex INTEGER,
|
|
battManUnitStatusSerialNumber DisplayString,
|
|
battManUnitHardwareRev INTEGER,
|
|
battManUnitFirmwareRev INTEGER,
|
|
battManUnitCommLoss INTEGER,
|
|
battManUnitRelayStuck INTEGER
|
|
}
|
|
|
|
battManUnitStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of unit status entries in the table."
|
|
::= { battManUnitStatusEntry 1 }
|
|
|
|
battManUnitStatusSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery manager unit serial number character string.
|
|
This value is set at the factory."
|
|
::= { battManUnitStatusEntry 2 }
|
|
|
|
battManUnitHardwareRev OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery manager unit hardware revision.
|
|
This value is set at the factory."
|
|
::= { battManUnitStatusEntry 3 }
|
|
|
|
battManUnitFirmwareRev OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery manager unit firmware revision.
|
|
This value is set at the factory and can change with firmware update."
|
|
::= { battManUnitStatusEntry 4 }
|
|
|
|
battManUnitCommLoss OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates the system has lost
|
|
communication with the unit."
|
|
::= { battManUnitStatusEntry 5 }
|
|
|
|
battManUnitRelayStuck OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When set to alarm(2), indicates the unit monitor relay
|
|
is stuck."
|
|
::= { battManUnitStatusEntry 6 }
|
|
|
|
|
|
-- the xPDUIdent group
|
|
|
|
xPDUIdentProductName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the PDU."
|
|
::= { xPDUIdent 1 }
|
|
|
|
xPDUIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the PDU.
|
|
This value is set at the factory."
|
|
::= { xPDUIdent 2 }
|
|
|
|
xPDUIdentFirmwareAppRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ID string identifying the application firmware revision of the PDU."
|
|
::= { xPDUIdent 3 }
|
|
|
|
xPDUIdentFirmwareAppOSRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ID string identifying the application operating system firmware revision of the PDU."
|
|
::= { xPDUIdent 4 }
|
|
|
|
xPDUIdentFirmwareControllerRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ID string identifying the PDU controller firmware revision."
|
|
::= { xPDUIdent 5 }
|
|
|
|
xPDUIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the PDU was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory."
|
|
::= { xPDUIdent 6 }
|
|
|
|
xPDUIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the model number of
|
|
the PDU. This value is set at the factory."
|
|
::= { xPDUIdent 7 }
|
|
|
|
xPDUIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the serial number of
|
|
the PDU. This value is set at the factory."
|
|
::= { xPDUIdent 8 }
|
|
|
|
-- the xPDUDevice group
|
|
|
|
xPDUDeviceNominalMainInputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal main input voltage to the PDU. Measured in Volts,
|
|
line-to-line for a 3-wire (delta) service or line-to-neutral for a
|
|
4-wire (wye) service."
|
|
::= { xPDUDevice 1 }
|
|
|
|
xPDUDeviceServiceType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
threeWire (1),
|
|
fourWire (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye)."
|
|
::= { xPDUDevice 2 }
|
|
|
|
xPDUDeviceNominalOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal line-to-neutral output voltage to the load measured in Volts."
|
|
::= { xPDUDevice 3 }
|
|
|
|
xPDUDeviceMainInputBreakerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rating of the main input breaker measured in Amps."
|
|
::= { xPDUDevice 4 }
|
|
|
|
xPDUDevicePanelBreakerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rating of the panel breaker measured in Amps."
|
|
::= { xPDUDevice 5 }
|
|
|
|
xPDUDeviceTransformerPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not a transformer is installed in the PDU."
|
|
::= { xPDUDevice 6 }
|
|
|
|
xPDUDeviceLoadTieBreakerPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not a load tie breaker is installed in the PDU."
|
|
::= { xPDUDevice 7 }
|
|
|
|
xPDUDeviceLoadTestPortPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not a load test port is installed in the PDU."
|
|
::= { xPDUDevice 8 }
|
|
|
|
xPDUDeviceFusesPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not the UPS feed from the PDU includes fuses."
|
|
::= { xPDUDevice 9 }
|
|
|
|
xPDUDeviceFansPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not cooling fans are installed in the PDU."
|
|
::= { xPDUDevice 10 }
|
|
|
|
xPDUDeviceBypassInputPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not the PDU is equipped with a second feed for
|
|
the UPS's bypass input."
|
|
::= { xPDUDevice 11 }
|
|
|
|
xPDUDeviceCrossTieOutputPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not the PDU is equipped with a cross-tie output."
|
|
::= { xPDUDevice 12 }
|
|
|
|
xPDUDeviceEarthGroundMonitorPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not the PDU can provide ground current measurements."
|
|
::= { xPDUDevice 13 }
|
|
|
|
xPDUDeviceInfraStruXureType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
typeB (1),
|
|
typeC (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the configuration of this PDU system.
|
|
Type-B PDU is in a distributed UPS system and has bypass capabilities.
|
|
Type-C PDU receives power from a larger central UPS."
|
|
::= { xPDUDevice 14 }
|
|
|
|
-- Main Input
|
|
|
|
xPDUMainInputOverVoltThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold above which an input over voltage condition will be generated.
|
|
Specified as percent deviation from nominal."
|
|
::= { xPDUMainInput 1 }
|
|
|
|
xPDUMainInputUnderVoltThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which an input under voltage condition will be generated.
|
|
Specified as percent deviation from nominal.
|
|
A value of zero indicates that the threshold is disabled."
|
|
::= { xPDUMainInput 2 }
|
|
|
|
-- Main Input Voltage Table
|
|
|
|
xPDUMainInputVoltageTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Main input voltage entries."
|
|
::= { xPDUMainInput 3 }
|
|
|
|
xPDUMainInputVoltagePhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XPDUMainInputVoltagePhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of input voltage table entries. The number of
|
|
entries are the phase entries.
|
|
The number of entries is contained in the
|
|
xPDUMainInputVoltageTableSize OID."
|
|
::= { xPDUMainInput 4 }
|
|
|
|
xPDUMainInputVoltagePhaseEntry OBJECT-TYPE
|
|
SYNTAX XPDUMainInputVoltagePhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular main input voltage phase."
|
|
INDEX { xPDUMainInputVoltagePhaseIndex }
|
|
::= { xPDUMainInputVoltagePhaseTable 1 }
|
|
|
|
XPDUMainInputVoltagePhaseEntry ::= SEQUENCE {
|
|
xPDUMainInputVoltagePhaseIndex INTEGER,
|
|
xPDUMainInputVoltageLtoL INTEGER,
|
|
xPDUMainInputVoltageLtoN INTEGER
|
|
}
|
|
|
|
xPDUMainInputVoltagePhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each input phase entry in the table."
|
|
::= { xPDUMainInputVoltagePhaseEntry 1 }
|
|
|
|
xPDUMainInputVoltageLtoL OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-line PDU input voltage when an isolation transformer is present,
|
|
or -1 if no transformer present in this PDU. Measured in tenths of Volts."
|
|
::= { xPDUMainInputVoltagePhaseEntry 2 }
|
|
|
|
xPDUMainInputVoltageLtoN OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-neutral PDU input voltage when an isolation transformer is not present,
|
|
or -1 if a transformer is present in this PDU. Measured in tenths of Volts."
|
|
::= { xPDUMainInputVoltagePhaseEntry 3 }
|
|
|
|
|
|
xPDUBypassInputOverVoltThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold above which a bypass input over voltage condition will be generated.
|
|
Specified as percent deviation from nominal."
|
|
::= { xPDUBypassInput 1 }
|
|
|
|
xPDUBypassInputUnderVoltThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which an bypass input under voltage condition will be generated.
|
|
Specified as percent deviation from nominal.
|
|
A value of zero indicates that the threshold is disabled."
|
|
::= { xPDUBypassInput 2 }
|
|
|
|
-- Bypass Input Voltage Table
|
|
|
|
xPDUBypassInputVoltagePhaseTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of bypass input voltage entries."
|
|
::= { xPDUBypassInput 3 }
|
|
|
|
xPDUBypassInputVoltagePhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XPDUBypassInputVoltagePhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries are the phase entries.
|
|
The number of entries is contained in the
|
|
xPDUBypassInputVoltagePhaseTableSize OID."
|
|
::= { xPDUBypassInput 4 }
|
|
|
|
xPDUBypassInputVoltagePhaseEntry OBJECT-TYPE
|
|
SYNTAX XPDUBypassInputVoltagePhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input voltage phase."
|
|
INDEX { xPDUBypassInputVoltagePhaseIndex }
|
|
::= { xPDUBypassInputVoltagePhaseTable 1 }
|
|
|
|
XPDUBypassInputVoltagePhaseEntry ::= SEQUENCE {
|
|
xPDUBypassInputVoltagePhaseIndex INTEGER,
|
|
xPDUBypassInputVoltageLtoL INTEGER,
|
|
xPDUBypassInputVoltageLtoN INTEGER
|
|
}
|
|
|
|
xPDUBypassInputVoltagePhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of each bypass input phase entry in the table."
|
|
::= { xPDUBypassInputVoltagePhaseEntry 1 }
|
|
|
|
xPDUBypassInputVoltageLtoL OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-line bypass input voltage, or -1 if no bypass
|
|
feed is present in this PDU. Measured in tenths of Volts."
|
|
::= { xPDUBypassInputVoltagePhaseEntry 2 }
|
|
|
|
xPDUBypassInputVoltageLtoN OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-neutral bypass input voltage, or -1 if no bypass
|
|
feed is present in this PDU. Measured in tenths of Volts."
|
|
::= { xPDUBypassInputVoltagePhaseEntry 3 }
|
|
|
|
-- UPS Input Table
|
|
|
|
xPDUUPSInputVoltagePhaseTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of UPS input voltage entries."
|
|
::= { xPDUUPSInput 1 }
|
|
|
|
xPDUUPSInputVoltagePhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XPDUUPSInputVoltagePhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of UPS input table entries. The number of
|
|
entries are the phase entries.
|
|
The number of entries is contained in the
|
|
xPDUUPSInputVoltagePhaseTableSize OID."
|
|
::= { xPDUUPSInput 2 }
|
|
|
|
xPDUUPSInputVoltagePhaseEntry OBJECT-TYPE
|
|
SYNTAX XPDUUPSInputVoltagePhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular UPS input voltage phase."
|
|
INDEX { xPDUUPSInputVoltagePhaseIndex }
|
|
::= { xPDUUPSInputVoltagePhaseTable 1 }
|
|
|
|
XPDUUPSInputVoltagePhaseEntry ::= SEQUENCE {
|
|
xPDUUPSInputVoltagePhaseIndex INTEGER,
|
|
xPDUUPSInputVoltageLtoNPresent INTEGER
|
|
}
|
|
|
|
xPDUUPSInputVoltagePhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each UPS input phase entry in the table."
|
|
::= { xPDUUPSInputVoltagePhaseEntry 1 }
|
|
|
|
xPDUUPSInputVoltageLtoNPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not voltage is present at the UPS feed."
|
|
::= { xPDUUPSInputVoltagePhaseEntry 2 }
|
|
|
|
-- System Output
|
|
|
|
xPDUSystemOutputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system output frequency in tenths of Hertz."
|
|
::= { xPDUSystemOutput 1 }
|
|
|
|
xPDUSystemOutputNeutralCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Shows the neutral current measured at the system output in tenths of Amps."
|
|
::= { xPDUSystemOutput 2 }
|
|
|
|
xPDUSystemOutputTotalPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Shows the total system output power in tenths of kW."
|
|
::= { xPDUSystemOutput 3 }
|
|
|
|
xPDUSystemOutputTotalApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Shows the total system output power in tenths of kVA."
|
|
::= { xPDUSystemOutput 4 }
|
|
|
|
xPDUSystemOutputTotalPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the total power factor of the system output.
|
|
A value of 100 representing a unity power factor (1.00).
|
|
Measured in hundredths."
|
|
::= { xPDUSystemOutput 5 }
|
|
|
|
xPDUSystemOutputFrequencyTolerance OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
freqToleranceOff (1),
|
|
freqTolerancePointTwo (2),
|
|
freqTolerancePointFive (3),
|
|
freqToleranceOne (4),
|
|
freqToleranceOnePointFive (5),
|
|
freqToleranceTwo (6),
|
|
freqToleranceThree (7),
|
|
freqToleranceFour (8),
|
|
freqToleranceFive (9),
|
|
freqToleranceNine (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Shows the circuit panel output frequency tolerance in Hertz."
|
|
::= { xPDUSystemOutput 6 }
|
|
|
|
xPDUSystemOutputMaxKWPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines 100% load in kW.
|
|
Purpose is to set to match UPS capabilities."
|
|
::= { xPDUSystemOutput 7 }
|
|
|
|
xPDUSystemOutputOverVoltThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold above which an output over voltage condition will be generated.
|
|
Specified as percent deviation from nominal."
|
|
::= { xPDUSystemOutput 8 }
|
|
|
|
xPDUSystemOutputUnderVoltThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which an output under voltage condition will be generated.
|
|
Specified as percent deviation from nominal.
|
|
A value of zero indicates that the threshold is disabled."
|
|
::= { xPDUSystemOutput 9 }
|
|
|
|
|
|
xPDUSystemOutputOverCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold above which an over current condition will be generated.
|
|
Specified as a percent of the panel breaker rating.
|
|
A value of zero indicates that the threshold is disabled."
|
|
::= { xPDUSystemOutput 10 }
|
|
|
|
xPDUSystemOutputOverCurrentNeutralThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold above which an Over current neutral condition will be generated.
|
|
Specified as a percent of the panel breaker rating.
|
|
A value of zero indicates that the threshold is disabled."
|
|
::= { xPDUSystemOutput 11 }
|
|
|
|
xPDUSystemOutputUnderCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which an under current condition will be generated.
|
|
Specified as a percent of the panel breaker rating.
|
|
A value of zero indicates that the threshold is disabled."
|
|
::= { xPDUSystemOutput 12 }
|
|
|
|
xPDUSystemOutputTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of System Output phase entries."
|
|
::= { xPDUSystemOutput 13 }
|
|
|
|
xPDUSystemOutputPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XPDUSystemOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of system output table entries.
|
|
The number of entries is contained in the
|
|
xPDUSystemOutputTableSize OID."
|
|
::= { xPDUSystemOutput 14 }
|
|
|
|
xPDUSystemOutputPhaseEntry OBJECT-TYPE
|
|
SYNTAX XPDUSystemOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular system output phase."
|
|
INDEX { xPDUSystemOutputPhaseIndex }
|
|
::= { xPDUSystemOutputPhaseTable 1 }
|
|
|
|
XPDUSystemOutputPhaseEntry ::= SEQUENCE {
|
|
xPDUSystemOutputPhaseIndex INTEGER,
|
|
xPDUSystemOutputVoltageLtoL INTEGER,
|
|
xPDUSystemOutputVoltageLtoN INTEGER,
|
|
xPDUSystemOutputPhaseCurrent INTEGER,
|
|
xPDUSystemOutputPower INTEGER,
|
|
xPDUSystemOutputApparentPower INTEGER,
|
|
xPDUSystemOutputPowerFactor INTEGER
|
|
}
|
|
|
|
xPDUSystemOutputPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each output phase entry in the table."
|
|
::= { xPDUSystemOutputPhaseEntry 1 }
|
|
|
|
xPDUSystemOutputVoltageLtoL OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-line system output voltage available at the circuit panel.
|
|
Measured in tenths of Volts."
|
|
::= { xPDUSystemOutputPhaseEntry 2 }
|
|
|
|
xPDUSystemOutputVoltageLtoN OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-neutral system output voltage available at the circuit panel.
|
|
Measured in tenths of Volts."
|
|
::= { xPDUSystemOutputPhaseEntry 3 }
|
|
|
|
|
|
xPDUSystemOutputPhaseCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System load current per phase. Measured in tenths of Amps."
|
|
::= { xPDUSystemOutputPhaseEntry 4 }
|
|
|
|
xPDUSystemOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System output power per phase. Measured in tenths of kW."
|
|
::= { xPDUSystemOutputPhaseEntry 5 }
|
|
|
|
xPDUSystemOutputApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System output power per phase. Measured in tenths of kVA."
|
|
::= { xPDUSystemOutputPhaseEntry 6 }
|
|
|
|
xPDUSystemOutputPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Power Factor of the system output per phase.
|
|
A value of 100 representing a unity Power Factor (1.00).
|
|
Measured in hundredths."
|
|
::= { xPDUSystemOutputPhaseEntry 7 }
|
|
|
|
xPDUGroundCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Shows the current measured in the earth ground conductor.
|
|
Measured in tenths of Amps, or -1 if not available."
|
|
::= { xPDUGroundMonitorPoint 1 }
|
|
|
|
xPDUGroundCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..50)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold above which a ground current over current
|
|
condition will be generated. Specified in tenths of Amps."
|
|
::= { xPDUGroundMonitorPoint 2 }
|
|
|
|
-- System Breakers
|
|
|
|
xPDUSystemBreakerTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of system breaker entries."
|
|
::= { xPDUSystemBreakers 1 }
|
|
|
|
xPDUSystemBreakerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XPDUSystemBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of system breaker entries.
|
|
The number of entries is contained in the
|
|
xPDUSystemBreakerTableSize OID."
|
|
::= { xPDUSystemBreakers 2 }
|
|
|
|
xPDUSystemBreakerEntry OBJECT-TYPE
|
|
SYNTAX XPDUSystemBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular system breaker."
|
|
INDEX { xPDUSystemBreakerTableIndex }
|
|
::= { xPDUSystemBreakerTable 1 }
|
|
|
|
XPDUSystemBreakerEntry ::= SEQUENCE {
|
|
xPDUSystemBreakerTableIndex INTEGER,
|
|
xPDUSystemBreakerDescription DisplayString,
|
|
xPDUSystemBreakerPosition INTEGER
|
|
}
|
|
|
|
xPDUSystemBreakerTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of system breaker entries in the table."
|
|
::= { xPDUSystemBreakerEntry 1 }
|
|
|
|
xPDUSystemBreakerDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..79))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A brief description of the system breakers."
|
|
::= { xPDUSystemBreakerEntry 2 }
|
|
|
|
xPDUSystemBreakerPosition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether this breaker is open(1) or closed(2)."
|
|
::= { xPDUSystemBreakerEntry 3 }
|
|
|
|
-- Branch Breakers (Breaker Panel)
|
|
|
|
xPDUNumOfBranchBreakers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of branch breakers (panel positions) in the Panel.
|
|
returns 42 for a 1-panel or 84 for a 2-panel system."
|
|
::= { xPDUBranchBreakers 1 }
|
|
|
|
-- Branch Breakers Table
|
|
|
|
xPDUBranchBreakerTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of branch breaker entries determined by the xPDUNumOfBranchBreakers OID."
|
|
::= { xPDUBranchBreakers 2 }
|
|
|
|
xPDUBranchBreakerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XPDUBranchBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of branch breaker table entries. The
|
|
number of entries is given by the value of xPDUBranchBreakerTableSize
|
|
The number of entries is contained in the xPDUBranchBreakerTableSize OID."
|
|
::= { xPDUBranchBreakers 3 }
|
|
|
|
xPDUBranchBreakerEntry OBJECT-TYPE
|
|
SYNTAX XPDUBranchBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular branch breaker (panel position)."
|
|
INDEX { xPDUBranchBreakerTableIndex }
|
|
::= { xPDUBranchBreakerTable 1 }
|
|
|
|
XPDUBranchBreakerEntry ::= SEQUENCE {
|
|
xPDUBranchBreakerTableIndex INTEGER,
|
|
xPDUBranchBreakerRating INTEGER,
|
|
xPDUBranchBreakerRDPFeed INTEGER,
|
|
xPDUBranchBreakerTieIndicator INTEGER,
|
|
xPDUBranchBreakerCurrent INTEGER,
|
|
xPDUBranchBreakerOverCurrentThreshold INTEGER,
|
|
xPDUBranchBreakerUnderCurrentThreshold INTEGER,
|
|
xPDUBranchBreakerMaxCurrentThreshold INTEGER,
|
|
xPDUBranchBreakerMinCurrentThreshold INTEGER,
|
|
xPDUBranchBreakerName DisplayString,
|
|
xPDUBranchBreakerLocation DisplayString
|
|
}
|
|
|
|
xPDUBranchBreakerTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of branch breaker entries in the table."
|
|
::= { xPDUBranchBreakerEntry 1 }
|
|
|
|
xPDUBranchBreakerRating OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates current rating of this breaker.
|
|
0=Breaker is not present.
|
|
1=Earth leakage connection.
|
|
2=Neutral connection.
|
|
A value greater than 2 indicates breaker current rating in Amps.
|
|
A value above 60 Amp will signify a remote feed.
|
|
The xPDUBranchBreakerRDPFeed OID will indicate which breakers are
|
|
configured as a remote drop.
|
|
Note: When setting branch circuit thresholds/ratings for an entry,
|
|
all positions tied (see the xPDUBranchBreakerTieIndicator OID)
|
|
to this entry will inherit the new threshold/rating."
|
|
::= { xPDUBranchBreakerEntry 2 }
|
|
|
|
xPDUBranchBreakerRDPFeed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
remoteDistribution (1),
|
|
noRemoteDistribution (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates that a breaker position is feeding a remote
|
|
distribution panel."
|
|
::= { xPDUBranchBreakerEntry 3 }
|
|
|
|
xPDUBranchBreakerTieIndicator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
breakerUnTied (1),
|
|
breakerTied (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not the breaker in this position
|
|
is logically associated with the breaker immediately below it.
|
|
This setting is used grouping the breakers feeding
|
|
a multi-pole branch circuit.
|
|
Note: When setting an entry's branch breaker tie indicator to breakerTied,
|
|
all the positions that are tied to this breaker will take on the rating
|
|
and thresholds for this entry of the table."
|
|
::= { xPDUBranchBreakerEntry 4 }
|
|
|
|
xPDUBranchBreakerCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the branch current in tenths of Amps or -1 when not available."
|
|
::= { xPDUBranchBreakerEntry 5 }
|
|
|
|
xPDUBranchBreakerOverCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold above which a branch circuit high current
|
|
condition will be generated.
|
|
Specified as a percent of the branch breaker rating.
|
|
A value of zero indicates that the threshold is disabled.
|
|
Note: When setting branch circuit thresholds/ratings for an entry,
|
|
all positions tied (see the xPDUBranchBreakerTieIndicator OID)
|
|
to this entry will inherit the new threshold/rating."
|
|
::= { xPDUBranchBreakerEntry 6 }
|
|
|
|
xPDUBranchBreakerUnderCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which a branch circuit low current
|
|
condition will be generated.
|
|
Specified as a percent of the branch breaker rating.
|
|
A value of zero indicates that the threshold is disabled.
|
|
Note: When setting branch circuit thresholds/ratings for an entry,
|
|
all positions tied (see the xPDUBranchBreakerTieIndicator OID)
|
|
to this entry will inherit the new threshold/rating."
|
|
::= { xPDUBranchBreakerEntry 7 }
|
|
|
|
xPDUBranchBreakerMaxCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold above which a branch circuit maximum current
|
|
condition will be generated.
|
|
Specified as a percent of the branch breaker rating.
|
|
A value of zero indicates that the threshold is disabled.
|
|
Note: When setting branch circuit thresholds/ratings for an entry,
|
|
all positions tied (see the xPDUBranchBreakerTieIndicator OID)
|
|
to this entry will inherit the new threshold/rating."
|
|
::= { xPDUBranchBreakerEntry 8 }
|
|
|
|
xPDUBranchBreakerMinCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which a branch circuit minimum current
|
|
condition will be generated.
|
|
Specified as a percent of the branch breaker rating.
|
|
A value of zero indicates that the threshold is disabled.
|
|
Note: When setting branch circuit thresholds/ratings for an entry,
|
|
all positions tied (see the xPDUBranchBreakerTieIndicator OID)
|
|
to this entry will inherit the new threshold/rating."
|
|
::= { xPDUBranchBreakerEntry 9 }
|
|
|
|
xPDUBranchBreakerName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the purpose/use of the breaker."
|
|
::= { xPDUBranchBreakerEntry 10 }
|
|
|
|
xPDUBranchBreakerLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the location of the breaker."
|
|
::= { xPDUBranchBreakerEntry 11 }
|
|
|
|
|
|
-- the xPDUInputContacts group
|
|
|
|
xPDUInputContactNumContacts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of contacts supported by the PDU."
|
|
::= { xPDUInputContacts 1 }
|
|
|
|
xPDUInputContactTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input contact entries."
|
|
::= { xPDUInputContacts 2 }
|
|
|
|
xPDUInputContactTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XPDUInputContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of contacts supported by the PDU.
|
|
The number of entries is contained in the
|
|
xPDUInputContactTableSize OID."
|
|
::= { xPDUInputContacts 3 }
|
|
|
|
xPDUInputContactEntry OBJECT-TYPE
|
|
SYNTAX XPDUInputContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A contact entry containing information for a given contact."
|
|
INDEX { xPDUInputContactNumber }
|
|
::= { xPDUInputContactTable 1 }
|
|
|
|
XPDUInputContactEntry ::=
|
|
SEQUENCE {
|
|
xPDUInputContactNumber INTEGER,
|
|
xPDUInputContactName DisplayString,
|
|
xPDUInputContactNormalState INTEGER,
|
|
xPDUInputContactCurrentState INTEGER
|
|
}
|
|
|
|
xPDUInputContactNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An index identifying the contact on the PDU."
|
|
::= { xPDUInputContactEntry 1 }
|
|
|
|
xPDUInputContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the purpose/use of the contact."
|
|
::= { xPDUInputContactEntry 2 }
|
|
|
|
xPDUInputContactNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal operating position of the contact."
|
|
::= { xPDUInputContactEntry 3 }
|
|
|
|
xPDUInputContactCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value indicates the current state of the contact."
|
|
::= { xPDUInputContactEntry 4 }
|
|
|
|
-- the xPDUOutputRelays group
|
|
|
|
xPDUOutputRelaysNumRelays OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output relays supported by the PDU."
|
|
::= { xPDUOutputRelays 1 }
|
|
|
|
xPDUOutputRelaysTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output relay entries."
|
|
::= { xPDUOutputRelays 2 }
|
|
|
|
xPDUOutputRelayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XPDUOutputRelayEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output relays supported by the PDU.
|
|
The number of entries is contained in the
|
|
xPDUOutputRelayTableSize OID."
|
|
::= { xPDUOutputRelays 3 }
|
|
|
|
xPDUOutputRelayEntry OBJECT-TYPE
|
|
SYNTAX XPDUOutputRelayEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A output relay entry containing information for a given contact."
|
|
INDEX { xPDUOutputRelayNumber }
|
|
::= { xPDUOutputRelayTable 1 }
|
|
|
|
XPDUOutputRelayEntry ::=
|
|
SEQUENCE {
|
|
xPDUOutputRelayNumber INTEGER,
|
|
xPDUOutputRelayName DisplayString,
|
|
xPDUOutputRelayNormalState INTEGER,
|
|
xPDUOutputRelayCurrentState INTEGER
|
|
}
|
|
|
|
xPDUOutputRelayNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An index identifying the output relay on the PDU."
|
|
::= { xPDUOutputRelayEntry 1 }
|
|
|
|
xPDUOutputRelayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the purpose/use of the output relay."
|
|
::= { xPDUOutputRelayEntry 2 }
|
|
|
|
xPDUOutputRelayNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal operating position of the output relay."
|
|
::= { xPDUOutputRelayEntry 3 }
|
|
|
|
xPDUOutputRelayCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value indicates the current state of the output relay."
|
|
::= { xPDUOutputRelayEntry 4 }
|
|
|
|
-- the xPDUMiscGroup
|
|
|
|
xPDUEPOMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
armed (1),
|
|
disarmed (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the EPO System is armed(1) or disarmed(2)."
|
|
::= { xPDUMiscGroup 1 }
|
|
|
|
xPDUTransformTempStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
overtemp (2),
|
|
noTransformerPresent (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if the PDU's isolation transformer is over temperature."
|
|
::= { xPDUMiscGroup 2 }
|
|
|
|
xPDUCoolingFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
failed (2),
|
|
noCoolingFansPresent (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if one or more of the PDU's cooling fans have failed."
|
|
::= { xPDUMiscGroup 3 }
|
|
|
|
-- The xATSIdent group
|
|
|
|
xATSIdentProductName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the transfer switch unit."
|
|
::= { xATSIdent 1 }
|
|
|
|
xATSIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the transfer switch.
|
|
This value is set at the factory."
|
|
::= { xATSIdent 2 }
|
|
|
|
xATSIdentFirmwareAppRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ID string identifying the application firmware revision of the transfer switch."
|
|
::= { xATSIdent 3 }
|
|
|
|
xATSIdentFirmwareAppOSRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ID string identifying the application operating system firmware revision of the transfer switch."
|
|
::= { xATSIdent 4 }
|
|
|
|
xATSIdentFirmwareControllerRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ID string identifying the transfer switch controller firmware revision."
|
|
::= { xATSIdent 5 }
|
|
|
|
xATSIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the transfer switch was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory."
|
|
::= { xATSIdent 6 }
|
|
|
|
xATSIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the model number of the transfer switch.
|
|
This value is set at the factory."
|
|
::= { xATSIdent 7 }
|
|
|
|
xATSIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the serial number of the transfer switch.
|
|
This value is set at the factory."
|
|
::= { xATSIdent 8 }
|
|
|
|
-- The xATSDevice group
|
|
|
|
xATSDeviceServiceType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
threeWire (1),
|
|
fourWire (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of utility input to the transfer switch.
|
|
Either 3 wires (delta), or 4 wires (wye)."
|
|
::= { xATSDevice 1 }
|
|
|
|
xATSDeviceNominalVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal line-to-neutral system voltage.
|
|
Measured in Volts, line-to-line for a 3-wire service or
|
|
line-to-neutral for a 4-wire service. -1 if not available."
|
|
::= { xATSDevice 2 }
|
|
|
|
xATSDeviceNominalFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal system frequency. Measured in tenths of Hertz.
|
|
-1 if not available."
|
|
::= { xATSDevice 3 }
|
|
|
|
xATSDeviceTransferSwitchRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rating of the transfer switch.
|
|
Measured in Amps."
|
|
::= { xATSDevice 4 }
|
|
|
|
xATSDeviceDCBackUpPresent OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if a DC backup is present or not."
|
|
::= { xATSDevice 5 }
|
|
|
|
-- The xATS Switch Status group
|
|
|
|
xATSSwitchStatusSelectedSource OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
none (1),
|
|
source1 (2),
|
|
source2 (3),
|
|
fault (4),
|
|
unknown (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The source which is currently selected, i.e. supplying power to the load."
|
|
::= { xATSSwitchStatus 1 }
|
|
|
|
xATSSwitchStatusOperationalMode OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
automatic (1),
|
|
notInAutoAbnormal (2),
|
|
notInAuto (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current operating mode of the transfer switch. When the ATS is in
|
|
automatic mode, generator starting and ATS transferring is all done automatically
|
|
as needed based on the state of source 1. Automatic operation is halted when the
|
|
ATS is in either of the notInAuto modes.
|
|
A mode of notInAuto indicates that the automatic operation switch is in the
|
|
disabled position, as indicated by the xATSSwitchStatusAutomaticOperationSwitch OID.
|
|
The notInAutoAbnormal condition indicates that an abnormal
|
|
condition has caused the transfer switch to halt automatic operation.
|
|
In this case, traps can indicate the exact problem. In the case of
|
|
notInAutoAbnormal, refer to the operation manual for details
|
|
on how debug the condition and restore automatic operation."
|
|
::= { xATSSwitchStatus 2 }
|
|
|
|
xATSSwitchStatusAutomaticOperationSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
disabled (1),
|
|
enabled (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The position of the automatic operation switch on the front of the transfer switch."
|
|
::= { xATSSwitchStatus 3 }
|
|
|
|
xATSSwitchStatusEngineStartSignal OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
run (1),
|
|
stop (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The position of the Start/Stop contact which signals the generator
|
|
engine to start/run. When the ATS is in automatic mode,
|
|
generator starting/stopping is under ATS control."
|
|
::= { xATSSwitchStatus 4 }
|
|
|
|
-- The xATS Switch Setting group
|
|
|
|
xATSSwitchSettingsLowVoltageTransferPoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The lowest acceptable voltage condition at source 1.
|
|
When any phase of source 1 is lower than this voltage,
|
|
source quality is considered bad and the generator run signal
|
|
is asserted to begin generator operation.
|
|
Specified in volts, line-to-line for a 3-wire service or
|
|
line-to-neutral for a 4-wire service.
|
|
-1 if not available."
|
|
::= { xATSSwitchSettings 1 }
|
|
|
|
xATSSwitchSettingsHighVoltageTransferPoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The highest acceptable voltage condition at source 1.
|
|
When any phase of source 1 is greater than this voltage,
|
|
source quality is considered bad and the generator run signal
|
|
is asserted to begin generator operation.
|
|
Specified in volts, line-to-line for a 3-wire service or
|
|
line-to-neutral for a 4-wire service.
|
|
-1 if not available."
|
|
::= { xATSSwitchSettings 2 }
|
|
|
|
xATSSwitchSettingsMaxFrequencyDeviation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum acceptable frequency deviation condition from nominal at source 1.
|
|
When source 1 frequency is outside the specified range,
|
|
source quality is considered bad and the generator run signal
|
|
is asserted to begin generator operation.
|
|
Specified in tenths of Hertz above or below nominal.
|
|
A value of zero indicates that frequency is ignored when
|
|
determining source quality.
|
|
-1 if not available."
|
|
::= { xATSSwitchSettings 3 }
|
|
|
|
xATSSwitchSettingsMinPhaseBalance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum required phase balance at source 1.
|
|
When the percentage difference between the minimum and maximum
|
|
phase voltage measurements at source 1 is greater than this value,
|
|
source quality is considered bad and the generator run signal
|
|
is asserted to begin generator operation.
|
|
Specified as a percentage. A value of zero indicates that phase balance
|
|
is ignored when determining source quality. -1 if not available."
|
|
::= { xATSSwitchSettings 4 }
|
|
|
|
xATSSwitchSettingsNominalRotation OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
abc (1),
|
|
cba (2),
|
|
any (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal phase rotation (or phase sequence) required by the load.
|
|
For certain types of equipment, such as rotating machinery, phase rotation
|
|
is critical for proper operation as it determines the direction which motors
|
|
will rotate (clockwise or counterclockwise).
|
|
Source quality will be seen as bad if the rotation measured at that
|
|
ATS input does not match this setting.
|
|
If this setting is set to any, phase rotation is ignored."
|
|
::= { xATSSwitchSettings 5 }
|
|
|
|
xATSSwitchSettingsAllowClosedTransfer OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
yes (1),
|
|
no (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This setting enables seamless (closed) transfers between sources.
|
|
When possible, both source 1 and source 2 are closed to the output
|
|
for a brief time. If closed transfer is not possible within the amount
|
|
of time specified by the xATSSwitchSettingsMaxSyncTime OID,
|
|
an open transfer will be executed."
|
|
::= { xATSSwitchSettings 6 }
|
|
|
|
xATSSwitchSettingsMaxSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When attempting/seeking to perform a closed transfer, this setting defines
|
|
the maximum time allowed before the transfer switch will give up and perform
|
|
an open transfer. Specified in seconds.
|
|
-1 if not available."
|
|
::= { xATSSwitchSettings 7 }
|
|
|
|
xATSSwitchSettingsNeutralTransferTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This setting defines how long both source 1 and source 2 will be
|
|
disconnected from the output, during an open transfer.
|
|
Specified in seconds.
|
|
-1 if not available."
|
|
::= { xATSSwitchSettings 8 }
|
|
|
|
xATSSwitchSettingsClearLatchedAlarms OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears any latched alarm conditions."
|
|
::= { xATSSwitchSettings 9 }
|
|
|
|
xATSSwitchSettingsSetToFactoryDefaults OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sets all transfer switch settings to factory default values."
|
|
::= { xATSSwitchSettings 10 }
|
|
|
|
|
|
-- The xATSSwitchTimers group
|
|
|
|
xATSSwitchTimersTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of transfer switch timer entries."
|
|
::= { xATSSwitchTimers 1 }
|
|
|
|
xATSSwitchTimersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XATSSwitchTimersEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of timers supported by ATS.
|
|
The number of entries is contained in the xATSSwitchTimersTableSize OID."
|
|
::= { xATSSwitchTimers 2 }
|
|
|
|
xATSSwitchTimersEntry OBJECT-TYPE
|
|
SYNTAX XATSSwitchTimersEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information about an individual ATS timer."
|
|
INDEX { xATSSwitchTimersIndex }
|
|
::= { xATSSwitchTimersTable 1 }
|
|
|
|
XATSSwitchTimersEntry ::=
|
|
SEQUENCE {
|
|
xATSSwitchTimersIndex INTEGER,
|
|
xATSSwitchTimersName DisplayString,
|
|
xATSSwitchTimersAbort INTEGER,
|
|
xATSSwitchTimersStatus INTEGER,
|
|
xATSSwitchTimersRemainingTime INTEGER,
|
|
xATSSwitchTimersDelaySetting INTEGER
|
|
}
|
|
|
|
xATSSwitchTimersIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of timer entries in the table."
|
|
::= { xATSSwitchTimersEntry 1 }
|
|
|
|
xATSSwitchTimersName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the individual timer.Refer to ATS operation manual,
|
|
or on-line help, for detailed descriptions of ATS timers."
|
|
::= { xATSSwitchTimersEntry 2 }
|
|
|
|
xATSSwitchTimersAbort OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This aborts the individual timer."
|
|
::= { xATSSwitchTimersEntry 3 }
|
|
|
|
xATSSwitchTimersStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
inactive (1),
|
|
active (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the individual timer. Designates whether this timer
|
|
entry is currently running or inactive."
|
|
::= { xATSSwitchTimersEntry 4 }
|
|
|
|
xATSSwitchTimersRemainingTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time remaining for this timer entry.
|
|
Specified in seconds."
|
|
::= { xATSSwitchTimersEntry 5 }
|
|
|
|
xATSSwitchTimersDelaySetting OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay settings associated with this timer entry.
|
|
When this timer entry is active, the timer value must exceed this setting
|
|
before the ATS behavior associated with this timer is executed.
|
|
Refer to ATS operation manual, or on-line help, for detailed
|
|
descriptions of ATS timers."
|
|
::= { xATSSwitchTimersEntry 6 }
|
|
|
|
-- The xATSSwitchBlockMap group
|
|
|
|
xATSSwitchBlockMapTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of blocking map entries, or how many ATS actions can be blocked."
|
|
::= { xATSSwitchBlockMap 1 }
|
|
|
|
xATSSwitchBlockMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XATSSwitchBlockMapEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of blocking maps supported by the ATS.
|
|
The number of entries is contained in the xATSSwitchBlockMapTableSize OID."
|
|
::= { xATSSwitchBlockMap 2 }
|
|
|
|
xATSSwitchBlockMapEntry OBJECT-TYPE
|
|
SYNTAX XATSSwitchBlockMapEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information about a specific ATS blocking map."
|
|
INDEX { xATSSwitchBlockMapIndex }
|
|
::= { xATSSwitchBlockMapTable 1 }
|
|
|
|
XATSSwitchBlockMapEntry ::=
|
|
SEQUENCE {
|
|
xATSSwitchBlockMapIndex INTEGER,
|
|
xATSSwitchBlockMapName DisplayString,
|
|
xATSSwitchBlockMapStatus INTEGER,
|
|
xATSSwitchBlockMapSetting INTEGER
|
|
}
|
|
|
|
xATSSwitchBlockMapIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of blocking map entries in the table."
|
|
::= { xATSSwitchBlockMapEntry 1 }
|
|
|
|
xATSSwitchBlockMapName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string describing the ATS action to be blocked."
|
|
::= { xATSSwitchBlockMapEntry 2 }
|
|
|
|
xATSSwitchBlockMapStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Represents the status of this blocking map entry, in bit-mapped format.
|
|
A non-zero value indicates that this entry's ATS action is currently being blocked.
|
|
The bit(s) set indicate which input(s) are causing the blocking (bit0, bit1, etc).
|
|
|
|
bit 0 - Contact 1
|
|
bit 1 - Contact 2
|
|
bit 2 - Contact 3
|
|
bit 3 - Contact 4."
|
|
::= { xATSSwitchBlockMapEntry 3 }
|
|
|
|
xATSSwitchBlockMapSetting OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This setting designates the inputs that block the ATS action
|
|
The mapping is specified as a bit-field, where each bit set indicates
|
|
the input that blocks the ATS action associated with the entry.
|
|
|
|
bit 0 - Contact 1
|
|
bit 1 - Contact 2
|
|
bit 2 - Contact 3
|
|
bit 3 - Contact 4."
|
|
::= { xATSSwitchBlockMapEntry 4 }
|
|
|
|
-- The xATSSwitchStatistics group
|
|
|
|
xATSSwitchStatisticsTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of transfer switch statistics entries."
|
|
::= { xATSSwitchStatistics 1 }
|
|
|
|
xATSSwitchStatisticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XATSSwitchStatisticsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of statistics supported by ATS.
|
|
The number of entries is contained in the xATSSwitchStatisticsTableSize OID."
|
|
::= { xATSSwitchStatistics 2 }
|
|
|
|
xATSSwitchStatisticsEntry OBJECT-TYPE
|
|
SYNTAX XATSSwitchStatisticsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information about an individual ATS statistic."
|
|
INDEX { xATSSwitchStatisticsIndex }
|
|
::= { xATSSwitchStatisticsTable 1 }
|
|
|
|
XATSSwitchStatisticsEntry ::=
|
|
SEQUENCE {
|
|
xATSSwitchStatisticsIndex INTEGER,
|
|
xATSSwitchStatisticsName DisplayString,
|
|
xATSSwitchStatisticsValue DisplayString,
|
|
xATSSwitchStatisticsReset INTEGER
|
|
}
|
|
|
|
xATSSwitchStatisticsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of ATS statistics entries in the table."
|
|
::= { xATSSwitchStatisticsEntry 1 }
|
|
|
|
xATSSwitchStatisticsName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the name of the ATS statistic associated with this entry."
|
|
::= { xATSSwitchStatisticsEntry 2 }
|
|
|
|
xATSSwitchStatisticsValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the value of the ATS statistic associated with this entry."
|
|
::= { xATSSwitchStatisticsEntry 3 }
|
|
|
|
xATSSwitchStatisticsReset OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This will reset the individual ATS statistic associated with this entry."
|
|
::= { xATSSwitchStatisticsEntry 4 }
|
|
|
|
-- The xATS Source 1 group
|
|
|
|
xATSSource1Name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"String used to identify source 1."
|
|
::= { xATSSource1 1 }
|
|
|
|
xATSSource1Position OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
open (1),
|
|
closed (2),
|
|
tripped (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current position of the switch at source 1."
|
|
::= { xATSSource1 2 }
|
|
|
|
xATSSource1Frequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frequency at source 1 in tenths of Hertz.
|
|
-1 if unavailable."
|
|
::= { xATSSource1 3 }
|
|
|
|
xATSSource1Quality OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
sourceGood (1),
|
|
lowVoltage (2),
|
|
highVoltage (3),
|
|
phaseImbalance (4),
|
|
freqOutOfRange (5),
|
|
badRotation (6),
|
|
unknown (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current line quality of source 1."
|
|
::= { xATSSource1 4 }
|
|
|
|
xATSSource1Rotation OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
abc (1),
|
|
cba (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase rotation measured at the source 1 input of the ATS.
|
|
The sequence is a reference to the order in which the three phases
|
|
pass the zero-crossing boundary in time."
|
|
::= { xATSSource1 5 }
|
|
|
|
xATSSource1TableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input voltage entries at the source 1 input of the ATS."
|
|
::= { xATSSource1 6 }
|
|
|
|
xATSSource1PhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XATSSource1PhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of voltage table entries for source 1. The number of
|
|
entries are the phase entries. The number of entries is contained in the
|
|
xATSSource1TableSize OID."
|
|
::= { xATSSource1 7 }
|
|
|
|
xATSSource1PhaseEntry OBJECT-TYPE
|
|
SYNTAX XATSSource1PhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input voltage phase at the source 1 input of the ATS."
|
|
INDEX { xATSSource1Index }
|
|
::= { xATSSource1PhaseTable 1 }
|
|
|
|
XATSSource1PhaseEntry ::= SEQUENCE {
|
|
xATSSource1Index INTEGER,
|
|
xATSSource1VoltageLtoL INTEGER,
|
|
xATSSource1VoltageLtoN INTEGER
|
|
}
|
|
|
|
xATSSource1Index OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each phase utilized at source 1."
|
|
::= { xATSSource1PhaseEntry 1 }
|
|
|
|
xATSSource1VoltageLtoL OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Source 1 line-to-line input voltage.
|
|
Measured in tenths of Volts."
|
|
::= { xATSSource1PhaseEntry 2 }
|
|
|
|
xATSSource1VoltageLtoN OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Source 1 line-to-neutral input voltage.
|
|
Measured in tenths of Volts. -1 for a 3-wire service type."
|
|
::= { xATSSource1PhaseEntry 3 }
|
|
|
|
-- The xATS Source 2 group
|
|
|
|
xATSSource2Name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"String used to identify source 2."
|
|
::= { xATSSource2 1 }
|
|
|
|
xATSSource2Position OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
open (1),
|
|
closed (2),
|
|
tripped (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current position of the switch at source 2."
|
|
::= { xATSSource2 2 }
|
|
|
|
xATSSource2Frequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frequency at source 2 in tenths of Hertz.
|
|
-1 if not available."
|
|
::= { xATSSource2 3 }
|
|
|
|
xATSSource2Quality OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
sourceGood (1),
|
|
lowVoltage (2),
|
|
highVoltage (3),
|
|
phaseImbalance (4),
|
|
freqOutOfRange (5),
|
|
badRotation (6),
|
|
unknown (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current line quality of source 2."
|
|
::= { xATSSource2 4 }
|
|
|
|
xATSSource2Rotation OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
abc (1),
|
|
cba (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase rotation measured at the source 2 input of the ATS.
|
|
-1 if not available."
|
|
::= { xATSSource2 5 }
|
|
|
|
xATSSource2TableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input voltage entries at the source 2 input of the ATS."
|
|
::= { xATSSource2 6 }
|
|
|
|
xATSSource2PhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XATSSource2PhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of voltage table entries for the source 2. The number of
|
|
entries are the phase entries. The number of entries is contained in the
|
|
xATSSource2TableSize OID."
|
|
::= { xATSSource2 7 }
|
|
|
|
xATSSource2PhaseEntry OBJECT-TYPE
|
|
SYNTAX XATSSource2PhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input voltage phase at the source 2 input of the ATS."
|
|
INDEX { xATSSource2Index }
|
|
::= { xATSSource2PhaseTable 1 }
|
|
|
|
XATSSource2PhaseEntry ::= SEQUENCE {
|
|
xATSSource2Index INTEGER,
|
|
xATSSource2VoltageLtoL INTEGER,
|
|
xATSSource2VoltageLtoN INTEGER
|
|
}
|
|
|
|
xATSSource2Index OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each phase utilized at the source 2."
|
|
::= { xATSSource2PhaseEntry 1 }
|
|
|
|
xATSSource2VoltageLtoL OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Source 2 line-to-line input voltage.
|
|
Measured in tenths of Volts."
|
|
::= { xATSSource2PhaseEntry 2 }
|
|
|
|
xATSSource2VoltageLtoN OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Source 2 line-to-neutral input voltage.
|
|
Measured in tenths of Volts. -1 for a 3-wire service type."
|
|
::= { xATSSource2PhaseEntry 3 }
|
|
|
|
-- The xATSSystemOutput
|
|
|
|
xATSSystemOutputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system output frequency in tenths of Hertz."
|
|
::= { xATSSystemOutput 1 }
|
|
|
|
xATSSystemOutputTotalPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Shows the total system output power in tenths of kW."
|
|
::= { xATSSystemOutput 2 }
|
|
|
|
xATSSystemOutputTotalApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Shows the total system output power in tenths of kVA."
|
|
::= { xATSSystemOutput 3 }
|
|
|
|
xATSSystemOutputTotalPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the total power factor of the system output.
|
|
A value of 100 representing a unity power factor (1.00)
|
|
Specified in hundredths."
|
|
::= { xATSSystemOutput 4 }
|
|
|
|
xATSSystemOutputFrequencyTolerance OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
freqToleranceOff (1),
|
|
freqTolerancePointTwo (2),
|
|
freqTolerancePointFive (3),
|
|
freqToleranceOne (4),
|
|
freqToleranceOnePointFive (5),
|
|
freqToleranceTwo (6),
|
|
freqToleranceThree (7),
|
|
freqToleranceFour (8),
|
|
freqToleranceFive (9),
|
|
freqToleranceNine (10)
|
|
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Shows the panel output frequency tolerance in +/- Hertz."
|
|
::= { xATSSystemOutput 5 }
|
|
|
|
xATSSystemOutputOverVoltThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold above which an output over voltage condition will be generated.
|
|
Specified as tenths of percent deviation from nominal.
|
|
A value of zero indicates that the threshold is disabled."
|
|
::= { xATSSystemOutput 6 }
|
|
|
|
xATSSystemOutputUnderVoltThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which an output under voltage condition will be generated.
|
|
Specified as tenths of percent deviation from nominal.
|
|
A value of zero indicates that the threshold is disabled."
|
|
::= { xATSSystemOutput 7 }
|
|
|
|
xATSSystemOutputOverCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold above which an over current condition will be generated.
|
|
Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID).
|
|
A value of zero indicates that the threshold is disabled."
|
|
::= { xATSSystemOutput 8 }
|
|
|
|
xATSSystemOutputUnderCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which an under current condition will be generated.
|
|
Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID).
|
|
A value of zero indicates that the threshold is disabled."
|
|
::= { xATSSystemOutput 9 }
|
|
|
|
xATSSystemOutputAlarmDelayThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Delay the generation of an output alarm.
|
|
Specified in seconds."
|
|
::= { xATSSystemOutput 10 }
|
|
|
|
xATSSystemOutputTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of system output phase entries."
|
|
::= { xATSSystemOutput 11 }
|
|
|
|
xATSSystemOutputPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XATSSystemOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of system output table entries.
|
|
The number of entries is contained in the xATSSystemOutputTableSize OID."
|
|
::= { xATSSystemOutput 12 }
|
|
|
|
xATSSystemOutputPhaseEntry OBJECT-TYPE
|
|
SYNTAX XATSSystemOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular system output phase."
|
|
INDEX { xATSSystemOutputPhaseIndex }
|
|
::= { xATSSystemOutputPhaseTable 1 }
|
|
|
|
XATSSystemOutputPhaseEntry ::= SEQUENCE {
|
|
xATSSystemOutputPhaseIndex INTEGER,
|
|
xATSSystemOutputVoltageLtoL INTEGER,
|
|
xATSSystemOutputVoltageLtoN INTEGER,
|
|
xATSSystemOutputPhaseCurrent INTEGER,
|
|
xATSSystemOutputPower INTEGER,
|
|
xATSSystemOutputApparentPower INTEGER,
|
|
xATSSystemOutputPowerFactor INTEGER
|
|
}
|
|
|
|
xATSSystemOutputPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each system output phase utilized in this device."
|
|
::= { xATSSystemOutputPhaseEntry 1 }
|
|
|
|
xATSSystemOutputVoltageLtoL OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-line system output voltage available at the circuit panel.
|
|
Measured in tenths of Volts. -1 if not available."
|
|
::= { xATSSystemOutputPhaseEntry 2 }
|
|
|
|
xATSSystemOutputVoltageLtoN OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-neutral system output voltage available at the circuit panel.
|
|
Measured in tenths of Volts. -1 for a 3-wire service type or if not available."
|
|
::= { xATSSystemOutputPhaseEntry 3 }
|
|
|
|
xATSSystemOutputPhaseCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System load current per phase. Measured in Amps.
|
|
-1 if not available."
|
|
::= { xATSSystemOutputPhaseEntry 4 }
|
|
|
|
xATSSystemOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System output power per phase. Measured in tenths of kW."
|
|
::= { xATSSystemOutputPhaseEntry 5 }
|
|
|
|
xATSSystemOutputApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"system output power per phase. Measured in tenths of kVA."
|
|
::= { xATSSystemOutputPhaseEntry 6 }
|
|
|
|
xATSSystemOutputPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"indicates the power factor of the system output per phase.
|
|
A value of 100 representing a unity power factor (1.00).
|
|
Measured in hundredths."
|
|
::= { xATSSystemOutputPhaseEntry 7 }
|
|
|
|
-- xATS TestingStatus group
|
|
|
|
xATSTestingStatusSelectTestProcess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
engineStartTest (1),
|
|
systemLoadTest (2),
|
|
generatorHoldTest (3),
|
|
cancelTest (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of tests that can be selected when no test has been scheduled.
|
|
engineStartTest and systemLoadTest may be selected when no tests
|
|
are running. Tests that are selected may be canceled manually."
|
|
::= { xATSTestingStatus 1 }
|
|
|
|
xATSTestingStatusTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTestInProcess (1),
|
|
testPending (2),
|
|
startingEngine (3),
|
|
engineWarmingUp (4),
|
|
awaitingTransferToS2 (5),
|
|
testingWithLoad (6),
|
|
awaitingRetransferToS1 (7),
|
|
testingWithoutLoad (8),
|
|
stoppingEngine (9),
|
|
holdingOnGenerator (10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The present system test status/state."
|
|
::= { xATSTestingStatus 2 }
|
|
|
|
xATSTestingStatusProfileWarmupTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time that the generator will warm up during a test.
|
|
This is portion of the test when the xATSTestingStatusTestStatus
|
|
OID returns the value engineWarmingUp.
|
|
Specified in seconds."
|
|
::= { xATSTestingStatus 3 }
|
|
|
|
xATSTestingStatusProfileLoadedTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time that ATS will apply the system load to the generator
|
|
during a system load test.
|
|
This is portion of the test when the xATSTestingStatusTestStatus
|
|
OID returns the value testingWithLoad.
|
|
Specified in minutes."
|
|
::= { xATSTestingStatus 4 }
|
|
|
|
xATSTestingStatusProfileUnloadedTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time that the generator will run following the warm up
|
|
portion of a start test, or the loaded portion of a load test.
|
|
This is portion of the test when the xATSTestingStatusTestStatus
|
|
OID returns the value testingWithoutLoad.
|
|
Specified in seconds."
|
|
::= { xATSTestingStatus 5 }
|
|
|
|
-- xATS TestingResults group
|
|
|
|
xATSTestingResultsLastDateOfTest OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date of the last test that was performed, either scheduled or manual.
|
|
Test results are available in the xATSTestingResultsLastResult OID.
|
|
Specified in the dd/mm/yyyy format, or 'none' if not available."
|
|
::= { xATSTestingResults 1 }
|
|
|
|
xATSTestingResultsLastResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noResultsAvailable (1),
|
|
startTestPassed (2),
|
|
loadTestPassed (3),
|
|
startSignalFailure (4),
|
|
failedGenNotInAuto (5),
|
|
failedGenEmerStop (6),
|
|
failedGenShutdown (7),
|
|
failedGenDidNotStart (8),
|
|
failedS2NeverGood (9),
|
|
genFailedDuringWarmup (10),
|
|
failureOnXferToS1 (11),
|
|
genFailedLoaded (12),
|
|
failureOnRexferToS2 (13),
|
|
failedOnCooldown (14),
|
|
genFailedToStop (15),
|
|
failedAtsInternalFault (16),
|
|
failedAtsNotInAuto (17),
|
|
canceledManualTest (18),
|
|
canceledScheduledTest (19)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The result of the last ATS/generator system test."
|
|
::= { xATSTestingResults 2 }
|
|
|
|
xATSTestingResultsTestLastTestTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time of day at which the last test was performed, either scheduled or manual.
|
|
Test results are available in the xATSTestingResultsLastResult OID.
|
|
Specified in the hh:mm:ss format, or 'none' if not available."
|
|
::= { xATSTestingResults 3 }
|
|
|
|
xATSTestingResultsLastCrankDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time spent cranking the generator before it started during the last test.
|
|
Specified in seconds, or -1 if not available."
|
|
::= { xATSTestingResults 4 }
|
|
|
|
xATSTestingResultsLastWarmupDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time spent in the engineWarmingUp state during the last system test.
|
|
Specified in seconds, or -1 if not available."
|
|
::= { xATSTestingResults 5 }
|
|
|
|
xATSTestingResultsLastLoadedDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time spent in the testingWithLoad state during the last system test.
|
|
Specified in seconds, or -1 if not available."
|
|
::= { xATSTestingResults 6 }
|
|
|
|
xATSTestingResultsLastUnloadedDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time spent in the testingWithoutLoad state during the last system test.
|
|
Specified in seconds, or -1 if not available."
|
|
::= { xATSTestingResults 7 }
|
|
|
|
-- xATS TestingSchedule group
|
|
|
|
xATSTestingScheduleFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
never (1),
|
|
daily (2),
|
|
weekly (3),
|
|
monthly (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frequency of running scheduled tests."
|
|
::= { xATSTestingSchedule 1 }
|
|
|
|
xATSTestingScheduleTestDay OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The desired day for the scheduled test. This object applies only
|
|
when the xATSTestingScheduleFrequency OID is set to weekly or monthly.
|
|
For weekly test frequency, the string is the day the test will be run.
|
|
For monthly test frequency, the string indicates the day,
|
|
and the instance within the month.
|
|
For example, for monthly frequency: 2nd Sunday, 3rd Monday, 4th Tuesday,
|
|
for weekly frequency: Sunday, Monday, Tuesday."
|
|
::= { xATSTestingSchedule 2 }
|
|
|
|
xATSTestingScheduleTestTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time of day that the scheduled test will occur.
|
|
Specified in the format hh:mm."
|
|
::= { xATSTestingSchedule 3 }
|
|
|
|
xATSTestingScheduleTestWithLoadInterval OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
applyLoadEveryTest (1),
|
|
neverApplyLoad (2),
|
|
applyLoadMonthly (3),
|
|
applyLoadMonthlyDetailed (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This setting specifies which system tests should include applying the
|
|
load to the generator. The applyLoadMonthlyDetailed entry
|
|
in the list will apply load once, for each month represented in the
|
|
xATSTestingScheduleTestWithLoadSelectMonth OID."
|
|
::= { xATSTestingSchedule 4 }
|
|
|
|
xATSTestingScheduleTestWithLoadSelectMonth OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The detailed selection for testing with load on a month-by-month basis.
|
|
This object is applicable when the xATSTestingScheduleTestWithLoadInterval
|
|
is set to applyLoadMonthlyDetailed. Otherwise this selection will be ignored.
|
|
Format for this string is a comma-separated entry of months.
|
|
For example: Jan,Mar,Dec.
|
|
The string will return 'No Months Scheduled' if no months have been selected."
|
|
::= { xATSTestingSchedule 5 }
|
|
|
|
xATSTestingScheduleNextTestDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of the next scheduled test, in the format dd-mmm-yyyy."
|
|
::= { xATSTestingSchedule 6 }
|
|
|
|
-- xATSTestingSimulatePowerFail group
|
|
|
|
xATSTestingSimulatePowerFailTest OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
cancelSimulation (1),
|
|
fiveSecondsSimulation (2),
|
|
tenSecondsSimulation (3),
|
|
thirtySecondsSimulation (4),
|
|
oneMinuteSimulation (5),
|
|
threeMinutesSimulation (6),
|
|
fiveMinutesSimulation (7),
|
|
tenMinutesSimulation (8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object executes a simulated power failure for the duration indicated.
|
|
Simulation can be aborted by selecting cancelSimulation."
|
|
::= { xATSTestingSimulatePowerFail 1 }
|
|
|
|
xATSTestingSimulatePowerFailTimeRemaining OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the time remaining in seconds, for a simulated power failure.
|
|
a value of zero indicates that simulated power failure is not active."
|
|
::= { xATSTestingSimulatePowerFail 2 }
|
|
|
|
-- The xATS Input Contact group
|
|
|
|
xATSInputContactNumContacts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of contacts supported by the ATS."
|
|
::= { xATSInputContacts 1 }
|
|
|
|
xATSInputContactTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input contact entries."
|
|
::= { xATSInputContacts 2 }
|
|
|
|
xATSInputContactTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XATSInputContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of contacts supported by the ATS.
|
|
The number of entries is contained in the
|
|
xATSInputContactTableSize OID."
|
|
::= { xATSInputContacts 3 }
|
|
|
|
xATSInputContactEntry OBJECT-TYPE
|
|
SYNTAX XATSInputContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A contact entry containing information for a given contact."
|
|
INDEX { xATSInputContactNumber }
|
|
::= { xATSInputContactTable 1 }
|
|
|
|
XATSInputContactEntry ::=
|
|
SEQUENCE {
|
|
xATSInputContactNumber INTEGER,
|
|
xATSInputContactName DisplayString,
|
|
xATSInputContactNormalState INTEGER,
|
|
xATSInputContactCurrentState INTEGER
|
|
}
|
|
|
|
xATSInputContactNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An index identifying the contact on the ATS."
|
|
::= { xATSInputContactEntry 1 }
|
|
|
|
xATSInputContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the purpose/use of the contact."
|
|
::= { xATSInputContactEntry 2 }
|
|
|
|
xATSInputContactNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal operating position of the contact."
|
|
::= { xATSInputContactEntry 3 }
|
|
|
|
xATSInputContactCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value indicates the current state of the contact."
|
|
::= { xATSInputContactEntry 4 }
|
|
|
|
-- the xATS OutputRelays group
|
|
|
|
xATSOutputRelayNumRelays OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output relays supported by the ATS."
|
|
::= { xATSOutputRelays 1 }
|
|
|
|
xATSOutputRelayTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output relay entries."
|
|
::= { xATSOutputRelays 2 }
|
|
|
|
xATSOutputRelayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XATSOutputRelayEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output relays supported by the ATS.
|
|
The number of entries is contained in the
|
|
xATSOutputRelayTableSize OID."
|
|
::= { xATSOutputRelays 3 }
|
|
|
|
xATSOutputRelayEntry OBJECT-TYPE
|
|
SYNTAX XATSOutputRelayEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A output relay entry containing information for a given contact."
|
|
INDEX { xATSOutputRelayNumber }
|
|
::= { xATSOutputRelayTable 1 }
|
|
|
|
XATSOutputRelayEntry ::=
|
|
SEQUENCE {
|
|
xATSOutputRelayNumber INTEGER,
|
|
xATSOutputRelayName DisplayString,
|
|
xATSOutputRelayNormalState INTEGER,
|
|
xATSOutputRelayCurrentState INTEGER
|
|
}
|
|
|
|
xATSOutputRelayNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An index identifying the output relay on the ATS."
|
|
::= { xATSOutputRelayEntry 1 }
|
|
|
|
xATSOutputRelayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the purpose/use of the output relay."
|
|
::= { xATSOutputRelayEntry 2 }
|
|
|
|
xATSOutputRelayNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal operating position of the output relay."
|
|
::= { xATSOutputRelayEntry 3 }
|
|
|
|
xATSOutputRelayCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value indicates the current state of the output relay."
|
|
::= { xATSOutputRelayEntry 4 }
|
|
|
|
-- The xATS Generator Ident group
|
|
|
|
xATSGeneratorIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the model number of the generator.
|
|
This value is set at the factory."
|
|
::= { xATSGeneratorIdent 1 }
|
|
|
|
xATSGeneratorIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the serial number of the generator.
|
|
This value is set at the factory."
|
|
::= { xATSGeneratorIdent 2 }
|
|
|
|
xATSGeneratorIdentDateofManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying when the generator was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory."
|
|
::= { xATSGeneratorIdent 3 }
|
|
|
|
xATSGeneratorIdentVoltageConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The voltage for which the generator's alternator is designed.
|
|
Specified in Volts line-to-line."
|
|
::= { xATSGeneratorIdent 4 }
|
|
|
|
xATSGeneratorIdentMaxPowerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The max power rating of the generator. Specified in kW."
|
|
::= { xATSGeneratorIdent 5 }
|
|
|
|
xATSGeneratorIdentAlternatorFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frequency for which the generator's alternator is designed.
|
|
Specified in Hertz."
|
|
::= { xATSGeneratorIdent 6 }
|
|
|
|
-- The xATS Generator Status group
|
|
|
|
xATSGeneratorStatusGeneratorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name or label for the generator connected to the source 2 of the ATS."
|
|
::= { xATSGeneratorStatus 1 }
|
|
|
|
xATSGeneratorStatusOperational OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
nocomm (1),
|
|
off (2),
|
|
ready (3),
|
|
starting (4),
|
|
idle (5),
|
|
running (6),
|
|
normalStop (7),
|
|
emergencyStop (8),
|
|
notInAuto (9),
|
|
shutdown (10),
|
|
unknown (11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The operational status of the generator. unavailable when unrecognized status is received."
|
|
::= { xATSGeneratorStatus 2 }
|
|
|
|
xATSGeneratorStatusModeSwitchPosition OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
off (1),
|
|
manual (2),
|
|
automatic (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The position of the generator's auto-mode switch.
|
|
In automatic mode, the generator is started and stopped via the
|
|
remote start contact, which has state indicated in the
|
|
xATSGeneratorStatusRemoteStart OID.
|
|
In manual mode generator start/stop control is via local command only.
|
|
Off prevents the generator from running."
|
|
::= { xATSGeneratorStatus 3 }
|
|
|
|
xATSGeneratorStatusRemoteStart OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
stop (1),
|
|
run (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the generator's remote start contact, which is
|
|
provided as an output from the transfer switch to start/stop the
|
|
generator when in automatic mode."
|
|
::= { xATSGeneratorStatus 4 }
|
|
|
|
-- The xATS Generator Advanced Status group
|
|
|
|
xATSGeneratorAdvStatusBatteryVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The voltage of the generator's starting battery.
|
|
Measured in tenths of VDC, or -1 if not available."
|
|
::= { xATSGeneratorAdvStatus 1 }
|
|
|
|
xATSGeneratorAdvStatusOilPressure OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The generator's engine oil pressure.
|
|
Measured in tenths of Psi or kPa, based on the
|
|
value of the xATSGeneratorSettingsMetricUnit OID,
|
|
or -1 if not available."
|
|
::= { xATSGeneratorAdvStatus 2 }
|
|
|
|
xATSGeneratorAdvStatusCoolantTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current coolant temperature in the generator.
|
|
Measured in degrees Celsius or Fahrenheit, based on the
|
|
value of the xATSGeneratorSettingsMetricUnit OID,
|
|
or -1 if not available."
|
|
::= { xATSGeneratorAdvStatus 3 }
|
|
|
|
xATSGeneratorAdvStatusEngineRPM OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current engine speed of the generator.
|
|
Measured in RPM, or -1 if not available."
|
|
::= { xATSGeneratorAdvStatus 4 }
|
|
|
|
xATSGeneratorAdvStatusOilLevel OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
ok (1),
|
|
low (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates adequate oil level in the generator."
|
|
::= { xATSGeneratorAdvStatus 5 }
|
|
|
|
xATSGeneratorAdvStatusCoolantLevel OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
ok (1),
|
|
low (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates adequate coolant level in the generator."
|
|
::= { xATSGeneratorAdvStatus 6 }
|
|
|
|
-- The xATS Generator Output group
|
|
|
|
xATSGeneratorOutputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output frequency of the generator.
|
|
Measured in tenths of Hertz, or -1 if not available."
|
|
::= { xATSGeneratorOutput 1 }
|
|
|
|
xATSGeneratorOutputTotalPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total output power of the generator.
|
|
Measured in tenths of tenths of kW, or -1 if not available."
|
|
::= { xATSGeneratorOutput 2 }
|
|
|
|
xATSGeneratorOutputTotalApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total output power of the generator.
|
|
Measured in tenths of kVA, or -1 if not available."
|
|
::= { xATSGeneratorOutput 3 }
|
|
|
|
xATSGeneratorOutputTotalPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the total load power factor of the generator.
|
|
A value of 100 representing a unity power factor (1.00),
|
|
or -1 when if not available."
|
|
::= { xATSGeneratorOutput 4 }
|
|
|
|
xATSGeneratorOutputTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of generator output phase entries."
|
|
::= { xATSGeneratorOutput 5 }
|
|
|
|
xATSGeneratorOutputPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XATSGeneratorOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of generator output table entries.
|
|
The number of entries is contained in the xATSGeneratorOutputTableSize OID."
|
|
::= { xATSGeneratorOutput 6 }
|
|
|
|
xATSGeneratorOutputPhaseEntry OBJECT-TYPE
|
|
SYNTAX XATSGeneratorOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular generator output phase."
|
|
INDEX { xATSGeneratorOutputPhaseIndex }
|
|
::= { xATSGeneratorOutputPhaseTable 1 }
|
|
|
|
XATSGeneratorOutputPhaseEntry ::= SEQUENCE {
|
|
xATSGeneratorOutputPhaseIndex INTEGER,
|
|
xATSGeneratorOutputVoltageLtoL INTEGER,
|
|
xATSGeneratorOutputVoltageLtoN INTEGER,
|
|
xATSGeneratorOutputPhaseCurrent INTEGER,
|
|
xATSGeneratorOutputPower INTEGER,
|
|
xATSGeneratorOutputApparentPower INTEGER,
|
|
xATSGeneratorOutputPowerFactor INTEGER
|
|
}
|
|
|
|
xATSGeneratorOutputPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each generator output phase utilized in this device."
|
|
::= { xATSGeneratorOutputPhaseEntry 1 }
|
|
|
|
xATSGeneratorOutputVoltageLtoL OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-line generator output voltage.
|
|
Measured in Volts, or -1 if not available."
|
|
::= { xATSGeneratorOutputPhaseEntry 2 }
|
|
|
|
xATSGeneratorOutputVoltageLtoN OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-neutral generator output voltage.
|
|
Measured in volts, or -1 if not available."
|
|
::= { xATSGeneratorOutputPhaseEntry 3 }
|
|
|
|
xATSGeneratorOutputPhaseCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generator load current per phase.
|
|
Measured in Amps, or -1 if not available."
|
|
::= { xATSGeneratorOutputPhaseEntry 4 }
|
|
|
|
xATSGeneratorOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generator output power per phase.
|
|
Measured in tenths of kW, or -1 if not available."
|
|
::= { xATSGeneratorOutputPhaseEntry 5 }
|
|
|
|
xATSGeneratorOutputApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generator output power per phase.
|
|
Measured in tenths of kVA, or -1 if not available."
|
|
::= { xATSGeneratorOutputPhaseEntry 6 }
|
|
|
|
xATSGeneratorOutputPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the load power factor of the generator output per phase.
|
|
A value of 100 representing a unity power factor (1.00),
|
|
or -1 if not available."
|
|
::= { xATSGeneratorOutputPhaseEntry 7 }
|
|
|
|
-- xATS Generator Settings group
|
|
|
|
xATSGeneratorSettingsVoltageAdjust OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The voltage adjust of the generator.
|
|
Specified in volts line-to-line,
|
|
or -1 if not available."
|
|
::= { xATSGeneratorSettings 1 }
|
|
|
|
xATSGeneratorSettingsFrequencyAdjust OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frequency adjust of the generator.
|
|
Specified in tenths of Hertz."
|
|
::= { xATSGeneratorSettings 2 }
|
|
|
|
xATSGeneratorSettingsStartDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay, in seconds, after the remote run signal is activated
|
|
before the generator's engine will be cranked to start,
|
|
or -1 if not available."
|
|
::= { xATSGeneratorSettings 3 }
|
|
|
|
xATSGeneratorSettingsStopDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay, in seconds, before the generator will stop
|
|
after the remote run signal is deactivated,
|
|
or -1 if not available."
|
|
::= { xATSGeneratorSettings 4 }
|
|
|
|
xATSGeneratorSettingsCrankCycleEnable OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
disabled (1),
|
|
enabled (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When Crank Cycle is enabled, the engine will be cranked up to the time
|
|
specified by the xATSGeneratorSettingsCrankTime OID.
|
|
If the generator's engine does not start, there will be a pause as
|
|
specified by the xATSGeneratorSettingsCrankRestTime OID before the
|
|
engine will be cranked again. This cycle is repeated as specified by
|
|
the xATSGeneratorSettingsNumberCrank OID.
|
|
When crank cycle is disabled, the generator's engine will be
|
|
cranked continuously until it starts."
|
|
::= { xATSGeneratorSettings 5 }
|
|
|
|
xATSGeneratorSettingsCrankTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The duration of engine cranking, in seconds, when starting the generator.
|
|
Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled.
|
|
-1 if not available."
|
|
::= { xATSGeneratorSettings 6 }
|
|
|
|
xATSGeneratorSettingsCrankRestTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The pause duration, in seconds, following an unsuccessful attempt to start the generator.
|
|
Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled.
|
|
-1 if not available."
|
|
::= { xATSGeneratorSettings 7 }
|
|
|
|
xATSGeneratorSettingsNumberCrank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of failed crank attempts before giving up on starting the generator.
|
|
Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled.
|
|
-1 if not available."
|
|
::= { xATSGeneratorSettings 8 }
|
|
|
|
xATSGeneratorSettingsMetricUnit OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the use of metric units in generator related OIDs, as well
|
|
as on all other interfaces including the generator's local interface."
|
|
::= { xATSGeneratorSettings 9 }
|
|
|
|
-- xATS generator service group
|
|
|
|
xATSGeneratorServiceTotalRunHoursLifetime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total time that the generator engine has been run,
|
|
over the life of the generator. Measured in hours.
|
|
-1 if not available."
|
|
::= { xATSGeneratorService 1 }
|
|
|
|
xATSGeneratorServiceEngineStartsLifetime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of engine starts over the life of the generator.
|
|
-1 if not available."
|
|
::= { xATSGeneratorService 2 }
|
|
|
|
xATSGeneratorServiceTotalkWhLifetime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total kWh of operation over the life of the generator.
|
|
-1 if not available."
|
|
::= { xATSGeneratorService 3 }
|
|
|
|
xATSGeneratorServiceTotalRunHoursSinceMaintenance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total time that the generator engine has been run,
|
|
since last service maintenance. Measured in tenths of hours.
|
|
-1 if not available."
|
|
::= { xATSGeneratorService 4 }
|
|
|
|
xATSGeneratorServiceEngineStartsSinceMaintenance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of engine starts since last service maintenance.
|
|
-1 if not available."
|
|
::= { xATSGeneratorService 5 }
|
|
|
|
xATSGeneratorServiceTotalkWhMaintenance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total kWh of operation since last service maintenance.
|
|
-1 if not available."
|
|
::= { xATSGeneratorService 6 }
|
|
|
|
xATSGeneratorServiceResetRecord OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Resets the engine start counter, engine run-hours, and kWh values that have
|
|
accumulated in the generator since last maintenance.
|
|
Also, the last service date will be reset to the current system date, and
|
|
any service alarms will be cleared."
|
|
::= { xATSGeneratorService 7 }
|
|
|
|
xATSGeneratorServiceRecordResetDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date at which the generator's service record was reset, in dd-mmm-yyyy format."
|
|
::= { xATSGeneratorService 8 }
|
|
|
|
xATSGeneratorServiceNextServiceDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date at which the next generator service is due in dd-mmm-yyyy format.
|
|
Based on the xATSGeneratorServiceCalendarIntervalThreshold OID
|
|
or '' if the calendar-based threshold is set to off."
|
|
::= { xATSGeneratorService 9 }
|
|
|
|
xATSGeneratorServiceRunHoursUntilServiceDate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Run hours until the next generator service is due, in hours.
|
|
Based on the xATSGeneratorServiceRunHoursThreshold OID
|
|
or -1 if the run hour-based threshold is set to off."
|
|
::= { xATSGeneratorService 10 }
|
|
|
|
xATSGeneratorServiceRunHoursThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
disabled (1),
|
|
runThreshold100Hours (2),
|
|
runThreshold150Hours (3),
|
|
runThreshold200Hours (4),
|
|
runThreshold250Hours (5),
|
|
runThreshold300Hours (6),
|
|
runThreshold400Hours (7),
|
|
runThreshold500Hours (8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Run hour-based service interval. When the run-hours since
|
|
service surpasses this threshold, generator service is due."
|
|
::= { xATSGeneratorService 11 }
|
|
|
|
xATSGeneratorServiceCalendarIntervalThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
disabled (1),
|
|
interval1month (2),
|
|
interval2month (3),
|
|
interval3month (4),
|
|
interval6month (5),
|
|
intervalyearly (6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Calendar-based service interval. When the next service date,
|
|
as indicated by the xATSGeneratorServiceNextServiceDate OID
|
|
is in the past, generator is due for service."
|
|
::= { xATSGeneratorService 12 }
|
|
|
|
-- The xATS Generator Fuel system group
|
|
|
|
xATSGeneratorFuelSystemType OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
diesel (1),
|
|
propane (2),
|
|
naturalGas (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of fuel used by the generator."
|
|
::= { xATSGeneratorFuelSystem 1 }
|
|
|
|
xATSGeneratorFuelSystemTankSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Size of the generator's fuel tank.
|
|
Specified in gallons or liters, based on the value of the
|
|
xATSGeneratorSettingsMetricUnit OID, or -1 if not available."
|
|
::= { xATSGeneratorFuelSystem 2 }
|
|
|
|
xATSGeneratorFuelSystemFuelLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel remaining in the generator tank.
|
|
Measured in percent of tank fill, or -1 if not available."
|
|
::= { xATSGeneratorFuelSystem 3 }
|
|
|
|
xATSGeneratorFuelSystemRuntimePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power value used in the runtime remaining calculation.
|
|
Measured in tenths of kW, or -1 if not available."
|
|
::= { xATSGeneratorFuelSystem 4 }
|
|
|
|
xATSGeneratorFuelSystemEstimatedRunTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An estimate of available runtime for the generator, based on
|
|
available fuel as specified in the xATSGeneratorFuelSystemFuelLevel OID
|
|
and kW load as specified in the xATSGeneratorFuelSystemRuntimePower OID.
|
|
Measured in tenths of hours, or -1 if not available."
|
|
::= { xATSGeneratorFuelSystem 5 }
|
|
|
|
xATSGeneratorFuelSystemLowRunTimeThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
disabled (1),
|
|
oneHour (2),
|
|
twoHours (3),
|
|
threeHours (4),
|
|
fourHours (5),
|
|
fiveHours (6),
|
|
sixHours (7),
|
|
twelveHours (8),
|
|
oneDay (9),
|
|
twoDays (10),
|
|
threeDays (11),
|
|
fourDays (12),
|
|
fiveDays (13),
|
|
sixDays (14),
|
|
sevenDays (15)
|
|
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which a low runtime alarm will exist."
|
|
::= { xATSGeneratorFuelSystem 6 }
|
|
|
|
xATSGeneratorFuelSystemVeryLowRunTimeThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
disabled (1),
|
|
oneHour (2),
|
|
twoHours (3),
|
|
threeHours (4),
|
|
fourHours (5),
|
|
fiveHours (6),
|
|
sixHours (7),
|
|
twelveHours (8),
|
|
oneDay (9),
|
|
twoDays (10),
|
|
threeDays (11),
|
|
fourDays (12),
|
|
fiveDays (13),
|
|
sixDays (14),
|
|
sevenDays (15)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which a very low runtime alarm will exist."
|
|
::= { xATSGeneratorFuelSystem 7 }
|
|
|
|
xATSGeneratorFuelSystemLowFuelLevelThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which a low fuel alarm will exist, with a value of 0 indicating disabled.
|
|
Specified as percent of tank fill."
|
|
::= { xATSGeneratorFuelSystem 8 }
|
|
|
|
xATSGeneratorFuelSystemVeryLowFuelLevelThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold below which a very low fuel alarm will exist, with a value of 0 indicating disabled.
|
|
Specified as percent of tank fill."
|
|
::= { xATSGeneratorFuelSystem 9 }
|
|
|
|
-- The console Port Server AP930x system group
|
|
|
|
apCPSpname OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The product's name."
|
|
::= { cpsAP930xSys 1 }
|
|
|
|
apCPSversion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The firmware's version."
|
|
::= {cpsAP930xSys 2}
|
|
|
|
apCPSPower OBJECT IDENTIFIER ::= { cpsAP930xSys 3 }
|
|
|
|
apCPSPwNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of the power supplies."
|
|
::= { apCPSPower 1 }
|
|
|
|
apCPSPw1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "State of the first power supply.
|
|
0 will indicate not installed,
|
|
1 will indicate power ON,
|
|
2 will indicate power OFF."
|
|
::= { apCPSPower 2 }
|
|
|
|
apCPSPw2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "State of the second power supply.
|
|
0 will indicate not installed,
|
|
1 will indicate power ON,
|
|
2 will indicate power OFF."
|
|
::= { apCPSPower 3 }
|
|
|
|
apCPSPcmcia OBJECT IDENTIFIER ::= {cpsAP930xSys 4}
|
|
|
|
apCPSNPcmcia OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number of PCMCIA cards available."
|
|
::= { apCPSPcmcia 1 }
|
|
|
|
cpsCardIdentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpsCardIdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of PCMCIA card identifications."
|
|
::= { apCPSPcmcia 2 }
|
|
|
|
cpsCardIdentEntry OBJECT-TYPE
|
|
SYNTAX CpsCardIdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Identification information for a PCMCIA card."
|
|
INDEX { cpsCardIdentIndex }
|
|
::= { cpsCardIdentTable 1 }
|
|
|
|
CpsCardIdentEntry ::= SEQUENCE {
|
|
cpsCardIdentIndex Integer32,
|
|
cpsCardIdentProd DisplayString,
|
|
cpsCardIdentMan DisplayString ,
|
|
cpsCardIdentFunc DisplayString,
|
|
cpsCardIdentPCI DisplayString
|
|
}
|
|
|
|
cpsCardIdentIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number to identify the socket Card."
|
|
::= { cpsCardIdentEntry 1 }
|
|
|
|
cpsCardIdentProd OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Product identification string."
|
|
::= { cpsCardIdentEntry 2 }
|
|
|
|
cpsCardIdentMan OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Manufacturer ID code."
|
|
::= { cpsCardIdentEntry 3 }
|
|
|
|
cpsCardIdentFunc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Function ID code."
|
|
::= { cpsCardIdentEntry 4 }
|
|
|
|
cpsCardIdentPCI OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "PCI ID"
|
|
::= { cpsCardIdentEntry 5 }
|
|
|
|
cpsCardConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpsCardConfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of socket configuration information."
|
|
::= { apCPSPcmcia 3 }
|
|
|
|
cpsCardConfEntry OBJECT-TYPE
|
|
SYNTAX CpsCardConfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Configuration information for a socket."
|
|
INDEX { cpsCardConfIndex }
|
|
::= { cpsCardConfTable 1 }
|
|
|
|
CpsCardConfEntry ::= SEQUENCE {
|
|
cpsCardConfIndex Integer32,
|
|
cpsCardConfPower DisplayString,
|
|
cpsCardConfType DisplayString,
|
|
cpsCardConfInter DisplayString,
|
|
cpsCardConfFunc DisplayString,
|
|
cpsCardConfCardv DisplayString,
|
|
cpsCardConfPort1 DisplayString,
|
|
cpsCardConfPort2 DisplayString
|
|
}
|
|
|
|
cpsCardConfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number to identify the socket PCMCIA."
|
|
::= { cpsCardConfEntry 1 }
|
|
|
|
cpsCardConfPower OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Power Settings."
|
|
::= { cpsCardConfEntry 2 }
|
|
|
|
cpsCardConfType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Interface Type."
|
|
::= { cpsCardConfEntry 3 }
|
|
|
|
cpsCardConfInter OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Interrupt number."
|
|
::= { cpsCardConfEntry 4 }
|
|
|
|
cpsCardConfFunc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Function."
|
|
::= { cpsCardConfEntry 5 }
|
|
|
|
cpsCardConfCardv OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Card values."
|
|
::= { cpsCardConfEntry 6 }
|
|
|
|
cpsCardConfPort1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "I/O Port 1."
|
|
::= { cpsCardConfEntry 7 }
|
|
|
|
cpsCardConfPort2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "I/O Port 2."
|
|
::= { cpsCardConfEntry 8 }
|
|
|
|
cpsCardStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpsCardStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "A table of current socket status information."
|
|
::= { apCPSPcmcia 4 }
|
|
|
|
cpsCardStatusEntry OBJECT-TYPE
|
|
SYNTAX CpsCardStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Current status information for a socket."
|
|
INDEX { cpsCardStatusIndex }
|
|
::= { cpsCardStatusTable 1 }
|
|
|
|
CpsCardStatusEntry ::= SEQUENCE {
|
|
cpsCardStatusIndex Integer32,
|
|
cpsCardStatusCard DisplayString,
|
|
cpsCardStatusFunc DisplayString
|
|
}
|
|
|
|
cpsCardStatusIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number to identify the socket PCMCIA."
|
|
::= { cpsCardStatusEntry 1 }
|
|
|
|
cpsCardStatusCard OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Current Card State."
|
|
::= { cpsCardStatusEntry 2 }
|
|
|
|
cpsCardStatusFunc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Current Function."
|
|
::= { cpsCardStatusEntry 3 }
|
|
|
|
apCPSFlashSize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Total amount of flash memory in Mbytes."
|
|
::= {cpsAP930xSys 5}
|
|
|
|
apCPSRAMSize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Total amount of RAM in Mbytes."
|
|
::= {cpsAP930xSys 6}
|
|
|
|
apCPSCPUfreq OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "CPU clock in MHz."
|
|
::= {cpsAP930xSys 7}
|
|
|
|
apCPSDevId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The product's identifier."
|
|
::= { cpsAP930xSys 8 }
|
|
|
|
|
|
-- The console Port Server AP930x configuration group
|
|
|
|
cpsHostName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The Host Name."
|
|
::= { cpsAP930xConf 1 }
|
|
|
|
cpsConsoleBanner OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The console banner."
|
|
::= { cpsAP930xConf 2 }
|
|
|
|
cpsMotd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The motd message."
|
|
::= { cpsAP930xConf 3 }
|
|
|
|
cpsEthItf OBJECT IDENTIFIER ::= { cpsAP930xConf 4 }
|
|
|
|
cpsEthDhcpc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "0 will indicate DHCP inactive,
|
|
1 will indicate DHCP active,
|
|
2 will indicate DHCP active and the last parameter is saved."
|
|
::= { cpsEthItf 1 }
|
|
|
|
cpsEthIPaddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This is the IP address of the Ethernet Interface."
|
|
::= { cpsEthItf 2 }
|
|
|
|
cpsEthIPmask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The mask for the Ethernet network."
|
|
::= { cpsEthItf 3 }
|
|
|
|
cpsEthMTU OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The Maximum Transmission Unit size, which determines
|
|
whether packets should be broken up."
|
|
::= { cpsEthItf 4 }
|
|
|
|
cpsEthIPaddr2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The Ethernet secondary IP address."
|
|
::= { cpsEthItf 5 }
|
|
|
|
cpsEthIPmask2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The Ethernet secondary IP mask."
|
|
::= { cpsEthItf 6 }
|
|
|
|
cpsNameService OBJECT IDENTIFIER ::= { cpsAP930xConf 5 }
|
|
|
|
cpsResolverOrder OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..15))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Specifies how host lookups are to be performed.
|
|
Valid values : empty, 'hosts', 'bind', 'hosts, bind',
|
|
'bind, hosts' "
|
|
::= { cpsNameService 1 }
|
|
|
|
cpsMultipleIP OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Valid values are ON or OFF. If set to ON, the resolve
|
|
library will return all valid addresses for a host
|
|
that appears in the /etc/hosts file, instead of only
|
|
the first. "
|
|
::= { cpsNameService 2 }
|
|
|
|
cpsDNSserv OBJECT IDENTIFIER ::= { cpsNameService 3 }
|
|
|
|
cpsDNSpriserv OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Internet Address (in dot notation) of primary name
|
|
server that the resolver should query."
|
|
::= { cpsDNSserv 1 }
|
|
|
|
cpsDNSsecserv OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Internet Address (in dot notation) of secondary name
|
|
server that the resolver should query."
|
|
::= { cpsDNSserv 2 }
|
|
|
|
cpsDNSdomain OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Local domain name."
|
|
::= { cpsDNSserv 3 }
|
|
|
|
cpsSerialPortConf OBJECT IDENTIFIER ::= { cpsAP930xConf 6 }
|
|
|
|
cpsSerialGlobal OBJECT IDENTIFIER ::= { cpsSerialPortConf 1 }
|
|
|
|
cpsSerialInclude OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "File used in centralized management."
|
|
::= { cpsSerialGlobal 1 }
|
|
|
|
cpsSerialNFS OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Remote Network File System where data buffering will be
|
|
written instead of the default directory '/var/run/DB'."
|
|
::= { cpsSerialGlobal 2 }
|
|
|
|
cpsSerialLockDir OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The lock directory."
|
|
::= { cpsSerialGlobal 3 }
|
|
|
|
cpsSerialRlogin OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Location of the rlogin binary that accepts the -i flag."
|
|
::= { cpsSerialGlobal 4 }
|
|
|
|
cpsSerialPppd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Location of the pppd binary."
|
|
::= { cpsSerialGlobal 5 }
|
|
|
|
cpsSerialTelnet OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Location of the telnet application."
|
|
::= { cpsSerialGlobal 6 }
|
|
|
|
cpsSerialSsh OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Location of the ssh application."
|
|
::= { cpsSerialGlobal 7 }
|
|
|
|
cpsSerialLocalLogins OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This parameter is only necessary when authentication is
|
|
being performed for a port.
|
|
This is useful if the Radius authentication server is down.
|
|
0 indicates OFF,
|
|
1 indicates ON."
|
|
::= { cpsSerialGlobal 8 }
|
|
|
|
cpsSerialFacility OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This value (0-7) is the Local facility sent to the syslog daemon."
|
|
::= { cpsSerialGlobal 9 }
|
|
|
|
cpsSerialDBFacility OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This value (0-7) is the Local facility sent to the syslog daemon."
|
|
::= { cpsSerialGlobal 10 }
|
|
|
|
cpsSerialGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpsSerialGroupEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { cpsSerialGlobal 11 }
|
|
|
|
cpsSerialGroupEntry OBJECT-TYPE
|
|
SYNTAX CpsSerialGroupEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX { cpsSerialGroupIndex }
|
|
::= { cpsSerialGroupTable 1 }
|
|
|
|
CpsSerialGroupEntry ::= SEQUENCE {
|
|
cpsSerialGroupIndex INTEGER,
|
|
cpsSerialGroupName DisplayString,
|
|
cpsSerialGroupUsers DisplayString
|
|
}
|
|
|
|
cpsSerialGroupIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number to identify the group."
|
|
::= { cpsSerialGroupEntry 1 }
|
|
|
|
cpsSerialGroupName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The group name."
|
|
::= { cpsSerialGroupEntry 2 }
|
|
|
|
cpsSerialGroupUsers OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..80))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The user's names."
|
|
::= { cpsSerialGroupEntry 3 }
|
|
|
|
cpsSerialSpec OBJECT IDENTIFIER ::= { cpsSerialPortConf 2 }
|
|
|
|
cpsSerialPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpsSerialPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "This is the specific configuration per serial port."
|
|
::= { cpsSerialSpec 1 }
|
|
|
|
cpsSerialPortEntry OBJECT-TYPE
|
|
SYNTAX CpsSerialPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "One particular serial port configuration."
|
|
INDEX { cpsSerialPortNumber }
|
|
::= { cpsSerialPortTable 1 }
|
|
|
|
CpsSerialPortEntry ::= SEQUENCE {
|
|
cpsSerialPortNumber INTEGER, -- 0 == all. X == ttyX sX.
|
|
cpsSerialPortTty DisplayString, -- associate device
|
|
cpsSerialPortName DisplayString, -- alias name
|
|
cpsSerialPortSpeed Integer32, -- physical port configuration
|
|
cpsSerialPortDataSize Integer32,
|
|
cpsSerialPortStopBits Integer32,
|
|
cpsSerialPortParity DisplayString,
|
|
cpsSerialPortFlowCtrl DisplayString,
|
|
cpsSerialPortDTRdelay Integer32,
|
|
cpsSerialPortDCDCtrl INTEGER,
|
|
cpsSerialPortLogUtmp INTEGER, -- log into UTMP
|
|
cpsSerialPortLogWtmp INTEGER, -- log into WTMP
|
|
cpsSerialPortLogform DisplayString,
|
|
cpsSerialPortAuthtype DisplayString, -- authentication type
|
|
cpsSerialPortAuthSrv1 IpAddress, -- IP address of the primary authentication server
|
|
cpsSerialPortAccSrv1 IpAddress, -- IP address of the primary accounting server
|
|
cpsSerialPortAuthTmo Integer32, -- time out per authentication query
|
|
cpsSerialPortAuthRetr Integer32, -- authentication number of retries
|
|
cpsSerialPortAuthSrv2 IpAddress, -- IP address of the secondary authentication server
|
|
cpsSerialPortAccSrv2 IpAddress, -- IP address of the secondary accounting server
|
|
cpsSerialPortAuthSecret DisplayString, -- secret used in authentication
|
|
cpsSerialPortAuthRadP INTEGER, -- accept RADIUS' user without password
|
|
cpsSerialPortAuthAcc DisplayString, -- access restriction on Users
|
|
cpsSerialPortProtocol DisplayString, -- Profile
|
|
cpsSerialPortRemoteIP DisplayString, -- remote IP address
|
|
cpsSerialPortSocketPort DisplayString, -- number of socket port
|
|
cpsSerialPortRemHost IpAddress, -- IP address of the remote Host
|
|
cpsSerialPortBanner DisplayString, -- Banner
|
|
cpsSerialPortPrompt DisplayString, -- Login prompt
|
|
cpsSerialPortTermType DisplayString, -- terminal type
|
|
cpsSerialPortAutomUsr DisplayString, -- automatic user
|
|
cpsSerialPortNetMask IpAddress, -- net mask
|
|
cpsSerialPortPppMtu Integer32,
|
|
cpsSerialPortPppMru Integer32,
|
|
cpsSerialPortPppOptions DisplayString,
|
|
cpsSerialPortPppFoption DisplayString,
|
|
cpsSerialPortModemChat DisplayString, -- initchat send to modem
|
|
cpsSerialPortSttyCmd DisplayString,
|
|
cpsSerialPortSockTx Integer32, -- socket transmission interval
|
|
cpsSerialPortSockPoll Integer32, -- socket polling interval
|
|
cpsSerialPortSockIdle Integer32, -- socket idle timeout
|
|
cpsSerialPortDBsize Integer32, -- maximum size of the data buffering file
|
|
cpsSerialPortDBtime INTEGER, -- data buffering with/without timestamp
|
|
cpsSerialPortDBmode DisplayString, -- data bufferinf mode circ or line
|
|
cpsSerialPortDBsyslog Integer32, -- size of the data send to syslog
|
|
cpsSerialPortDBmenu INTEGER, -- menu of the data buffering
|
|
cpsSerialPortDBalarm INTEGER, -- use alarm generating feature
|
|
cpsSerialPortSSHbreak DisplayString, -- break sequence (SSH)
|
|
cpsSerialPortSniffSess DisplayString, -- sniff session type
|
|
cpsSerialPortSniffAdm DisplayString, -- admin users to sniff
|
|
cpsSerialPortSniffEsc DisplayString, -- escape char to sniff session
|
|
cpsSerialPortSniffMsess DisplayString, -- multiple session
|
|
cpsSerialPortTelnetMode INTEGER, -- telnet client mode
|
|
cpsSerialPortSysBufSess INTEGER, -- syslog buffering at all times
|
|
cpsSerialPortLFSuppress INTEGER, -- LF suppression in socket_server session
|
|
cpsSerialPortAutoInput DisplayString, -- Input string to auto answer
|
|
cpsSerialPortAutoOutput DisplayString, -- Output string to auto answer
|
|
cpsSerialPortBreakInterval Integer32 -- Break interval (in ms)
|
|
}
|
|
|
|
cpsSerialPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number to identify the serial port. Value 0 is ALL."
|
|
::= { cpsSerialPortEntry 1 }
|
|
|
|
cpsSerialPortTty OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..25))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The device name for the serial port."
|
|
::= { cpsSerialPortEntry 2 }
|
|
|
|
cpsSerialPortName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Alias name given to the server connected to the serial port."
|
|
::= { cpsSerialPortEntry 3 }
|
|
|
|
cpsSerialPortSpeed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The speed of the serial port.
|
|
Supported values are:
|
|
50, 75, 110, 134, 150, 200, 300, 600,
|
|
1200, 1800, 2400, 4800, 9600, 14400, 19200,
|
|
28800, 38400, 57600, 115200, 230400, and 460800"
|
|
::= { cpsSerialPortEntry 4 }
|
|
|
|
cpsSerialPortDataSize OBJECT-TYPE
|
|
SYNTAX Integer32 (4..8)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The data size for the serial port."
|
|
::= { cpsSerialPortEntry 5 }
|
|
|
|
cpsSerialPortStopBits OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of stop bits for the serial port."
|
|
::= { cpsSerialPortEntry 6 }
|
|
|
|
cpsSerialPortParity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..5))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The parity for the serial port."
|
|
::= { cpsSerialPortEntry 7 }
|
|
|
|
cpsSerialPortFlowCtrl OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..5))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The flow control for the serial port."
|
|
::= { cpsSerialPortEntry 8 }
|
|
|
|
cpsSerialPortDTRdelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This specifies how long (in milliseconds) a DTR signal
|
|
will be turned off before it is turned on again."
|
|
::= { cpsSerialPortEntry 9 }
|
|
|
|
cpsSerialPortDCDCtrl OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "DCD signal controls the connection request.
|
|
0 will indicate nocontrol,
|
|
1 will indicate control."
|
|
::= { cpsSerialPortEntry 10 }
|
|
|
|
cpsSerialPortLogUtmp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Update the login records in /var/run/utmp file.
|
|
0 will indicate inactive,
|
|
1 will indicate active."
|
|
::= { cpsSerialPortEntry 11 }
|
|
|
|
cpsSerialPortLogWtmp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Update the login records in /var/run/wtmp file.
|
|
0 will indicate inactive,
|
|
1 will indicate active."
|
|
::= { cpsSerialPortEntry 12 }
|
|
|
|
cpsSerialPortLogform OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This is the format to write the login record."
|
|
::= { cpsSerialPortEntry 13 }
|
|
|
|
cpsSerialPortAuthtype OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..25))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Authentication type."
|
|
::= { cpsSerialPortEntry 14 }
|
|
|
|
cpsSerialPortAuthSrv1 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "IP address of the primary authentication server."
|
|
::= { cpsSerialPortEntry 15 }
|
|
|
|
cpsSerialPortAccSrv1 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "IP address of the primary accounting server."
|
|
::= { cpsSerialPortEntry 16 }
|
|
|
|
cpsSerialPortAuthTmo OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This is the timeout (in seconds) for the authentication
|
|
query to be answered."
|
|
::= { cpsSerialPortEntry 17 }
|
|
|
|
cpsSerialPortAuthRetr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This defines the number of times each server is tried
|
|
before another is contacted."
|
|
::= { cpsSerialPortEntry 18 }
|
|
|
|
cpsSerialPortAuthSrv2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "IP address of the secondary authentication server."
|
|
::= { cpsSerialPortEntry 19 }
|
|
|
|
cpsSerialPortAccSrv2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "IP address of the secondary accounting server."
|
|
::= { cpsSerialPortEntry 20 }
|
|
|
|
cpsSerialPortAuthSecret OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This is the shared secret with authentication servers."
|
|
::= { cpsSerialPortEntry 21 }
|
|
|
|
cpsSerialPortAuthRadP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Radius state.
|
|
0 will indicate inactive,
|
|
1 will indicate active."
|
|
::= { cpsSerialPortEntry 22 }
|
|
|
|
cpsSerialPortAuthAcc OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Access restriction."
|
|
::= { cpsSerialPortEntry 23 }
|
|
|
|
cpsSerialPortProtocol OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Defines the serial port's protocol."
|
|
::= { cpsSerialPortEntry 24 }
|
|
|
|
cpsSerialPortRemoteIP OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This is the default IP address of the serial port."
|
|
::= { cpsSerialPortEntry 25 }
|
|
|
|
cpsSerialPortSocketPort OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..10))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This defines an alternative labeling system for the serial port."
|
|
::= { cpsSerialPortEntry 26 }
|
|
|
|
cpsSerialPortRemHost OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The IP address of the host to which the serial port will connect."
|
|
::= { cpsSerialPortEntry 27 }
|
|
|
|
cpsSerialPortBanner OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..250))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This defines the banner."
|
|
::= { cpsSerialPortEntry 28 }
|
|
|
|
cpsSerialPortPrompt OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..250))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This defines the login prompt to the serial port."
|
|
::= { cpsSerialPortEntry 29 }
|
|
|
|
cpsSerialPortTermType OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This defines the terminal type."
|
|
::= { cpsSerialPortEntry 30 }
|
|
|
|
cpsSerialPortAutomUsr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This defines the automatic user."
|
|
::= { cpsSerialPortEntry 31 }
|
|
|
|
cpsSerialPortNetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The network mask used in dial in connection."
|
|
::= { cpsSerialPortEntry 32 }
|
|
|
|
cpsSerialPortPppMtu OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The PPP MTU - dial in connection."
|
|
::= { cpsSerialPortEntry 33 }
|
|
|
|
cpsSerialPortPppMru OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The PPP MRU - dial in connection."
|
|
::= { cpsSerialPortEntry 34 }
|
|
|
|
cpsSerialPortPppOptions OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The PPP options when the PPP session is autodetected."
|
|
::= { cpsSerialPortEntry 35 }
|
|
|
|
cpsSerialPortPppFoption OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The PPP forced options when the user has already been authenticated."
|
|
::= { cpsSerialPortEntry 36 }
|
|
|
|
cpsSerialPortModemChat OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The initchat send to modem connected."
|
|
::= { cpsSerialPortEntry 37 }
|
|
|
|
cpsSerialPortSttyCmd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..180))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The tty settings after socket connection is established."
|
|
::= { cpsSerialPortEntry 38 }
|
|
|
|
cpsSerialPortSockTx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Defines the delay (in milliseconds) before transmission to
|
|
the Ethernet of data received through a serial port."
|
|
::= { cpsSerialPortEntry 39 }
|
|
|
|
cpsSerialPortSockPoll OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Keep-alive timer (milliseconds) for the TCP connection."
|
|
::= { cpsSerialPortEntry 40 }
|
|
|
|
cpsSerialPortSockIdle OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The idle timeout in seconds."
|
|
::= { cpsSerialPortEntry 41 }
|
|
|
|
cpsSerialPortDBsize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Maximum size of the data buffering file."
|
|
::= { cpsSerialPortEntry 42 }
|
|
|
|
cpsSerialPortDBtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Timestamp in data buffering.
|
|
0 will indicate inactive,
|
|
1 will indicate active."
|
|
::= { cpsSerialPortEntry 43 }
|
|
|
|
cpsSerialPortDBmode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..5))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Data buffering mode : circ or line."
|
|
::= { cpsSerialPortEntry 44 }
|
|
|
|
cpsSerialPortDBsyslog OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Size of the data buffer sent to syslog."
|
|
::= { cpsSerialPortEntry 45 }
|
|
|
|
cpsSerialPortDBmenu OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Menu type for data buffering.
|
|
0 will indicate display Menu,
|
|
1 will indicate inactive,
|
|
2 will indicate DB,
|
|
3 will indicate Parc."
|
|
::= { cpsSerialPortEntry 46 }
|
|
|
|
cpsSerialPortDBalarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Alarm generation status.
|
|
0 will indicate inactive,
|
|
1 will indicate active."
|
|
::= { cpsSerialPortEntry 47 }
|
|
|
|
cpsSerialPortSSHbreak OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Break sequence - ssh session."
|
|
::= { cpsSerialPortEntry 48 }
|
|
|
|
cpsSerialPortSniffSess OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..5))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Sniff session type."
|
|
::= { cpsSerialPortEntry 49 }
|
|
|
|
cpsSerialPortSniffAdm OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "List of admin users allowed to sniff session."
|
|
::= { cpsSerialPortEntry 50 }
|
|
|
|
cpsSerialPortSniffEsc OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..6))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Escape sequence used in sniff session."
|
|
::= { cpsSerialPortEntry 51 }
|
|
|
|
cpsSerialPortSniffMsess OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { cpsSerialPortEntry 52 }
|
|
|
|
cpsSerialPortTelnetMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Mode negotiated by client telnet with the server.
|
|
0 will indicate text,
|
|
1 will indicate binary."
|
|
::= { cpsSerialPortEntry 53 }
|
|
|
|
cpsSerialPortSysBufSess OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Syslog Buffering at all times.
|
|
0 will indicate yes,
|
|
1 will indicate no."
|
|
::= { cpsSerialPortEntry 54 }
|
|
|
|
cpsSerialPortLFSuppress OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "LF suppression in socket_server session.
|
|
0 will indicate inactive,
|
|
1 will indicate active."
|
|
::= { cpsSerialPortEntry 55 }
|
|
|
|
cpsSerialPortAutoInput OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Input string used for auto answer."
|
|
::= { cpsSerialPortEntry 56 }
|
|
|
|
cpsSerialPortAutoOutput OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output string used for auto answer."
|
|
::= { cpsSerialPortEntry 57 }
|
|
|
|
cpsSerialPortBreakInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The break interval in milliseconds."
|
|
::= { cpsSerialPortEntry 58 }
|
|
|
|
-- The console Port Server AP930x information group
|
|
|
|
cpsInfoSerialPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpsInfoSerialPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "This is the information of the specific serial port."
|
|
::= { cpsAP930xInfo 1 }
|
|
|
|
cpsInfoSerialPortEntry OBJECT-TYPE
|
|
SYNTAX CpsInfoSerialPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "One particular serial port."
|
|
INDEX { cpsInfoSerialPortNumber }
|
|
::= { cpsInfoSerialPortTable 1 }
|
|
|
|
CpsInfoSerialPortEntry ::= SEQUENCE {
|
|
cpsInfoSerialPortNumber INTEGER, -- X == ttyX sX.
|
|
cpsInfoSerialPortTty DisplayString, -- associate device
|
|
cpsInfoSerialPortName DisplayString, -- alias name
|
|
cpsInfoSerialPortSpeed Integer32,
|
|
cpsInfoSerialPortTxBytes Integer32,
|
|
cpsInfoSerialPortRXBytes Integer32,
|
|
cpsInfoSerialPortErrFrame Integer32,
|
|
cpsInfoSerialPortErrParity Integer32,
|
|
cpsInfoSerialPortErrBreaks Integer32,
|
|
cpsInfoSerialPortErrOverrun Integer32,
|
|
cpsInfoSerialPortSigDTR INTEGER,
|
|
cpsInfoSerialPortSigCD INTEGER,
|
|
cpsInfoSerialPortSigDSR INTEGER,
|
|
cpsInfoSerialPortSigRTS INTEGER,
|
|
cpsInfoSerialPortSigCTS INTEGER,
|
|
cpsInfoSerialPortSigRI INTEGER
|
|
}
|
|
|
|
cpsInfoSerialPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number to identify the serial port."
|
|
::= { cpsInfoSerialPortEntry 1 }
|
|
|
|
cpsInfoSerialPortTty OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device name for the serial port."
|
|
::= { cpsInfoSerialPortEntry 2 }
|
|
|
|
cpsInfoSerialPortName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alias name given to the server connected to the serial port."
|
|
::= { cpsInfoSerialPortEntry 3 }
|
|
|
|
cpsInfoSerialPortSpeed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The speed for serial port."
|
|
::= { cpsInfoSerialPortEntry 4 }
|
|
|
|
cpsInfoSerialPortTxBytes OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of transmitted bytes by the serial port."
|
|
::= { cpsInfoSerialPortEntry 5 }
|
|
|
|
cpsInfoSerialPortRXBytes OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of received bytes by the serial port."
|
|
::= { cpsInfoSerialPortEntry 6 }
|
|
|
|
cpsInfoSerialPortErrFrame OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of frame errors."
|
|
::= { cpsInfoSerialPortEntry 7 }
|
|
|
|
cpsInfoSerialPortErrParity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of parity errors."
|
|
::= { cpsInfoSerialPortEntry 8 }
|
|
|
|
cpsInfoSerialPortErrBreaks OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of breaks errors."
|
|
::= { cpsInfoSerialPortEntry 9 }
|
|
|
|
cpsInfoSerialPortErrOverrun OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of overrun errors."
|
|
::= { cpsInfoSerialPortEntry 10 }
|
|
|
|
cpsInfoSerialPortSigDTR OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The state of the DTR signal.
|
|
0 will indicate down,
|
|
1 will indicate up."
|
|
::= { cpsInfoSerialPortEntry 11 }
|
|
|
|
cpsInfoSerialPortSigCD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The state of the DCD signal.
|
|
0 will indicate down,
|
|
1 will indicate up."
|
|
::= { cpsInfoSerialPortEntry 12 }
|
|
|
|
cpsInfoSerialPortSigDSR OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The state of the DSR signal.
|
|
0 will indicate down,
|
|
1 will indicate up."
|
|
::= { cpsInfoSerialPortEntry 13 }
|
|
|
|
cpsInfoSerialPortSigRTS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The state of the RTS signal.
|
|
0 will indicate down,
|
|
1 will indicate up."
|
|
::= { cpsInfoSerialPortEntry 14 }
|
|
|
|
cpsInfoSerialPortSigCTS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The state of the CTS signal.
|
|
0 will indicate down,
|
|
1 will indicate up."
|
|
::= { cpsInfoSerialPortEntry 15 }
|
|
|
|
cpsInfoSerialPortSigRI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The state of the RI signal.
|
|
0 will indicate down,
|
|
1 will indicate up."
|
|
::= { cpsInfoSerialPortEntry 16 }
|
|
|
|
-- The console Port Server AP930x administrative group
|
|
|
|
apCPSSave OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Exec saveconf command.
|
|
0 will indicate don't save,
|
|
1 will indicate save."
|
|
::= { cpsAP930xAdm 1 }
|
|
|
|
apCPSSerialHUP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Exec signal_ras hup command.
|
|
0 will indicate no restart,
|
|
1 will indicate restart."
|
|
::= { cpsAP930xAdm 2 }
|
|
|
|
-- the access PX group
|
|
|
|
accessPXIdentAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Access PX alarm status
|
|
1 = Normal
|
|
2 = Warning
|
|
3 = Critical."
|
|
::= { accessPXIdent 1 }
|
|
|
|
|
|
accessPXIdentProductNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The product number of the Access PX."
|
|
::= { accessPXIdent 2 }
|
|
|
|
accessPXIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision number of the Access PX."
|
|
::= { accessPXIdent 3 }
|
|
|
|
accessPXIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of manufacture of the Access PX."
|
|
::= { accessPXIdent 4 }
|
|
|
|
accessPXIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the Access PX."
|
|
::= { accessPXIdent 5 }
|
|
|
|
accessPXConfigCardReaderEnableDisableAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Action to disable/enable the card reader."
|
|
::= { accessPXConfig 1 }
|
|
|
|
accessPXConfigAutoRelockTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time (10 - 60) in seconds when the door will automatically relock
|
|
after it has been unlocked and the handle has not been opened."
|
|
::= { accessPXConfig 2 }
|
|
|
|
accessPXConfigCardFormat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
hidStd26 (1),
|
|
hid37Bit (2),
|
|
hid37BitWithFacility (3),
|
|
hidCorp1000 (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates and controls the HID card format.
|
|
NOTE: This OID is only valid for HID systems."
|
|
::= { accessPXConfig 3 }
|
|
|
|
accessPXConfigFrontDoorLockControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unlock (1),
|
|
lock (2),
|
|
notInstalledReadOnly (3),
|
|
disconnectedReadOnly (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control action (unlock, lock) for the front door. Setting this OID
|
|
will unlock or lock the front door. Getting this OID will respond
|
|
with the current state of the front door lock which could be
|
|
1 = unlocked,
|
|
2 = locked,
|
|
3 = not installed,
|
|
4 = disconnected."
|
|
::= { accessPXConfigFront 1 }
|
|
|
|
accessPXConfigFrontDoorMaxOpenTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in minutes, (1 - 120), that the front door can be
|
|
allowed to remain open without generating an alarm condition."
|
|
::= { accessPXConfigFront 2 }
|
|
|
|
accessPXStatusFrontDoorLock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unlocked (1),
|
|
locked (2),
|
|
notInstalled (3),
|
|
disconnected (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Present state of the front door lock: unlocked, locked,
|
|
not installed, or disconnected."
|
|
::= { accessPXStatusFront 1 }
|
|
|
|
accessPXStatusFrontDoor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2),
|
|
notInstalled (3),
|
|
disconnected (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Present state of the front door: open, closed,
|
|
not installed, or disconnected."
|
|
::= { accessPXStatusFront 2 }
|
|
|
|
accessPXStatusFrontDoorHandle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2),
|
|
notInstalled (3),
|
|
disconnected (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Present state of the front door handle: open, closed,
|
|
not installed, or disconnected."
|
|
::= { accessPXStatusFront 3 }
|
|
|
|
accessPXStatusFrontDoorMaxOpenTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in minutes, (1 - 120), that the front door can be
|
|
allowed to remain open without generating an alarm condition."
|
|
::= { accessPXStatusFront 4 }
|
|
|
|
accessPXStatusFrontDoorAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Front door alarm status
|
|
1 = Normal
|
|
2 = Warning
|
|
3 = Critical
|
|
4 = Front door not installed."
|
|
::= { accessPXStatusFront 5 }
|
|
|
|
accessPXConfigRearDoorLockControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unlock (1),
|
|
lock (2),
|
|
notInstalledReadOnly (3),
|
|
disconnectedReadOnly (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control action (unlock, lock) for the rear door. Setting this OID
|
|
will unlock or lock the rear door. Getting this OID will respond
|
|
with the current state of the rear door lock which could be
|
|
1 = unlocked,
|
|
2 = locked,
|
|
3 = not installed,
|
|
4 = disconnected."
|
|
::= { accessPXConfigRear 1 }
|
|
|
|
accessPXConfigRearDoorMaxOpenTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in minutes, (1 - 120), that the rear door can be
|
|
allowed to remain open without generating an alarm condition."
|
|
::= { accessPXConfigRear 2 }
|
|
|
|
accessPXStatusRearDoorLock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unlocked (1),
|
|
locked (2),
|
|
notInstalled (3),
|
|
disconnected (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Present state of the rear door lock: unlocked, locked,
|
|
not installed, or disconnected."
|
|
::= { accessPXStatusRear 1 }
|
|
|
|
accessPXStatusRearDoor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2),
|
|
notInstalled (3),
|
|
disconnected (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Present state of the rear door: open, closed,
|
|
not installed, or disconnected."
|
|
::= { accessPXStatusRear 2 }
|
|
|
|
accessPXStatusRearDoorHandle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2),
|
|
notInstalled (3),
|
|
disconnected (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Present state of the rear door handle: open, closed,
|
|
not installed, or disconnected."
|
|
::= { accessPXStatusRear 3 }
|
|
|
|
accessPXStatusRearDoorMaxOpenTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in minutes, (1 - 120), that the rear door can be
|
|
allowed to remain open without generating an alarm condition."
|
|
::= { accessPXStatusRear 4 }
|
|
|
|
accessPXStatusRearDoorAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Rear door alarm status
|
|
1 = Normal
|
|
2 = Warning
|
|
3 = Critical
|
|
4 = Rear door not installed."
|
|
::= { accessPXStatusRear 5 }
|
|
|
|
accessPXConfigBeaconName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for the Beacon."
|
|
::= { accessPXConfigBeacon 1 }
|
|
|
|
accessPXConfigBeaconLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for the location of the Beacon."
|
|
::= { accessPXConfigBeacon 2 }
|
|
|
|
accessPXConfigBeaconAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turnOff (1),
|
|
turnOn (2),
|
|
notInstalledReadOnly (3),
|
|
disconnectedReadOnly (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control action (turnOff, turnOn) for the beacon. Setting this OID
|
|
will turn the beacon off or on. Getting this OID will respond
|
|
with the current state which could be
|
|
1 = off,
|
|
2 = on,
|
|
3 = not installed,
|
|
4 = disconnected."
|
|
::= { accessPXConfigBeacon 3 }
|
|
|
|
accessPXStatusBeaconName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the beacon."
|
|
::= { accessPXStatusBeacon 1 }
|
|
|
|
accessPXStatusBeaconLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the location of the beacon."
|
|
::= { accessPXStatusBeacon 2 }
|
|
|
|
accessPXStatusBeaconCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2),
|
|
notInstalled (3),
|
|
disconnected (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of the beacon: off, on,
|
|
not installed, or disconnected."
|
|
::= { accessPXStatusBeacon 3 }
|
|
|
|
-- the apcLocalDisplay group
|
|
|
|
apcLocalDisplayIdentDisplayType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noDisplayFound (1),
|
|
powerviewRM (2),
|
|
powerviewWW (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numeric value used to identify the type of display in use."
|
|
::= { apcLocalDisplayIdent 1 }
|
|
|
|
apcLocalDisplayIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The model number of the local display."
|
|
::= { apcLocalDisplayIdent 2 }
|
|
|
|
apcLocalDisplayIdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision number of the local display."
|
|
::= { apcLocalDisplayIdent 3 }
|
|
|
|
apcLocalDisplayIdentOptions OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A display-specific string identifying options in the local display."
|
|
::= { apcLocalDisplayIdent 4 }
|
|
|
|
apcLocalDisplayIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of manufacture of the local display, if available."
|
|
::= { apcLocalDisplayIdent 5 }
|
|
|
|
apcLocalDisplayIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the local display, if available."
|
|
::= { apcLocalDisplayIdent 6 }
|
|
|
|
apcLocalDisplayConfigAlarmBeeper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
beeperDisabled (1),
|
|
beeperEnabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm beeper setting for the local display.
|
|
When enabled, the alarm beeper will begin to sound whenever
|
|
there a new alarm becomes active. The alarm beeper will continue to
|
|
periodically sound until a key is pressed on the display."
|
|
::= { apcLocalDisplayConfig 1 }
|
|
|
|
apcLocalDisplayConfigBeeperVolume OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
beeperDisabled (1),
|
|
beeperLow (2),
|
|
beeperMedium (3),
|
|
beeperHigh (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The volume setting of the beeper on the local display."
|
|
::= { apcLocalDisplayConfig 2 }
|
|
|
|
apcLocalDisplayConfigCheckLogIndicator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
checklogNotPresent (1),
|
|
checklogDisabled (2),
|
|
checklogInformational (3),
|
|
checklogWarning (4),
|
|
checklogCritical (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum level event severity level required to illuminate
|
|
the check log light on the local display.
|
|
notPresent (1) indicates that the display does not have a check log light."
|
|
::= { apcLocalDisplayConfig 3 }
|
|
|
|
apcLocalDisplayConfigKeyClick OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
keyclickDisabled (1),
|
|
keyclickEnabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The key click setting of the local display."
|
|
::= { apcLocalDisplayConfig 4 }
|
|
|
|
apcLocalDisplayConfigContrast OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
contrast1 (1),
|
|
contrast2 (2),
|
|
contrast3 (3),
|
|
contrast4 (4),
|
|
contrast5 (5),
|
|
contrast6 (6),
|
|
contrast7 (7),
|
|
contrast8 (8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The contrast level of the local display."
|
|
::= { apcLocalDisplayConfig 5 }
|
|
|
|
-- the software group
|
|
-- the powerNetSubAgent group
|
|
-- the powerNetSoftwareSystem group
|
|
|
|
powerNetSoftwareSystemDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..79))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A brief description of the PowerNet sub-agent."
|
|
::= { powerNetSoftwareSystem 1 }
|
|
|
|
powerNetSoftwareOid OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The object identifier of the PowerNet sub-agent."
|
|
::= { powerNetSoftwareSystem 2 }
|
|
|
|
-- powerNetSmuxPeer OBJECT IDENTIFIER ::= { powerNetSoftwareOid 1 }
|
|
-- powerNetDPIPeer OBJECT IDENTIFIER ::= { powerNetSoftwareOid 2 }
|
|
|
|
powerNetSoftwareSystemUpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time that the sub-agent has been running."
|
|
::= { powerNetSoftwareSystem 3 }
|
|
|
|
|
|
-- powerNetSoftwareConfig group
|
|
|
|
powerNetSoftwareTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of software modules supporting the UPS."
|
|
::= { powerNetSoftwareConfig 1 }
|
|
|
|
powerNetSoftwareTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PowerNetSoftwareEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of the software monitoring the UPS."
|
|
::= { powerNetSoftwareConfig 2 }
|
|
|
|
powerNetSoftwareEntry OBJECT-TYPE
|
|
SYNTAX PowerNetSoftwareEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information on a software module."
|
|
INDEX { moduleNumber }
|
|
::= { powerNetSoftwareTable 1 }
|
|
|
|
PowerNetSoftwareEntry ::=
|
|
SEQUENCE {
|
|
moduleNumber
|
|
INTEGER,
|
|
moduleName
|
|
DisplayString,
|
|
moduleVersion
|
|
DisplayString,
|
|
moduleDate
|
|
DisplayString
|
|
}
|
|
|
|
moduleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Software Entry Table"
|
|
::= { powerNetSoftwareEntry 1 }
|
|
|
|
moduleName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..79))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the software module."
|
|
::= { powerNetSoftwareEntry 2 }
|
|
|
|
moduleVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The version of the software module."
|
|
::= { powerNetSoftwareEntry 3 }
|
|
|
|
moduleDate OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..9))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of the software module represented as mm-dd-yy."
|
|
::= { powerNetSoftwareEntry 4 }
|
|
|
|
-- the StruxureWare Operations group
|
|
|
|
serverStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
stopped(2),
|
|
running(3),
|
|
running-missing(4),
|
|
initializing(5),
|
|
starting(6),
|
|
disaster-recovery(7),
|
|
postoffice-inconsistent(8),
|
|
missing-jgroups(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the StruxureWare Operations server:
|
|
1: The status of the application server is unknown. Check Webmin and if
|
|
the problem persists, contact Technical Support.
|
|
2: Restart the StruxureWare DC Operation server. If the server was part of
|
|
a cluster, see the StruxureWare DC Operation User Assistance about
|
|
rejoining the cluster. If the problem persists, contact Technical Support.
|
|
3: No problem.
|
|
4: High availability is lost. The StruxureWare DC Operation Application
|
|
server is running but one or more nodes are not available. If the
|
|
StruxureWare DC Operation server is part of a cluster, ensure all nodes
|
|
are running and there is a network connection between the nodes. If the
|
|
problem persists, contact Technical Support.
|
|
5: Wait for the StruxureWare DC Operation Application server to initialize.
|
|
If the problem persists, contact Technical Support.
|
|
6: Wait for the StruxureWare DC Operation Application server to finish
|
|
starting.
|
|
If the problem persists, contact Technical Support.
|
|
7: This node is running in Disaster Recovery mode.
|
|
8: The JBoss postoffice is currently inconsistent. This may be a temporary
|
|
issue. If the problem persists for more than 10 minutes,
|
|
contact Technical Support.
|
|
9: The JBoss is missing jgroups. This may be a temporary issue. If the
|
|
problem persists for more than 10 minutes, contact Technical Support."
|
|
::= { struxureWareOperationsStatus 1 }
|
|
|
|
databaseStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
stopped(2),
|
|
running(3),
|
|
detached(4),
|
|
catching-up(5),
|
|
attaching(6),
|
|
running-master(7),
|
|
running-primary-slave(8),
|
|
running-slave(9),
|
|
running-alone(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the StruxureWare Operations database:
|
|
1: The status of the database is unknown. Check Webmin and if the problem
|
|
persists, contact Technical Support.
|
|
2: Restart the StruxureWare DC Operation server. If the server was part of
|
|
a cluster, see the StruxureWare DC Operation User Assistance about
|
|
rejoining the cluster. If the problem persists, contact Technical Support.
|
|
3: No problem.
|
|
4: High availability is lost. The database is detached from the cluster
|
|
and does not receive updates. See the StruxureWare DC Operation User
|
|
Assistance about reattaching the database node to the StruxureWare DC
|
|
Operation cluster.
|
|
If the problem persists, contact Technical Support.
|
|
5: The database is catching up with the cluster. Wait for the StruxureWare
|
|
DC Operation database to retrieve all updates from the master node.
|
|
If the problem persists, contact Technical Support.
|
|
6: The database is attaching to the cluster. Wait for the StruxureWare
|
|
Operation database to attach to the cluster. If the problem persists,
|
|
contact Technical Support.
|
|
7: The database is the master in a cluster.
|
|
8: The database is the primary slave in the cluster. All changes on master
|
|
are synchronously replicated to this node.
|
|
9: The database is a secondary slave in the cluster. All changes on
|
|
master are asynchronously replicated to this node.
|
|
10: The database does not replicate its changes to other nodes."
|
|
::= { struxureWareOperationsStatus 2 }
|
|
|
|
loadBalancerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
stopped(2),
|
|
running(3),
|
|
running-missing(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the StruxureWare Operations load balancer:
|
|
1: Load Balancer status is unknown. Check Webmin and if the problem
|
|
persists, contact Technical Support.
|
|
2: Load Balancer stopped. Restart the StruxureWare DC Operation server.
|
|
If the problem persists, contact Technical Support.
|
|
3: Normal status
|
|
4: High availability is lost. The StruxureWare DC Operation Load Balancer
|
|
is running but one or more nodes are not available. If the StruxureWare DC
|
|
Operation server is part of a cluster, ensure all nodes are running and
|
|
there is a network connection between the nodes. If the problem persists,
|
|
contact Technical Support."
|
|
::= { struxureWareOperationsStatus 3 }
|
|
|
|
essentialServicesStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
stopped(2),
|
|
running(3),
|
|
time-sync-problems(4),
|
|
backup-problems(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the StruxureWare Operations essential services:
|
|
1: Unknown status. Check Webmin and if the problem persists, contact
|
|
Technical Support.
|
|
2: Essential services are not running on the StruxureWare DC Operation
|
|
server. Reboot the node and monitor the status page in Webmin. If the
|
|
problem persists, contact Technical Support.
|
|
3: Normal status
|
|
4: The time difference between the StruxureWare DC Operation slave and the
|
|
master node is too big. Correct the time on the slave to match the time on
|
|
the master. Consider using an NTP server. If the problem persists,
|
|
contact Technical Support.
|
|
5: The last backup that was attempted on the StruxureWare DC Operation
|
|
server has failed. Make certain that the system can write to the location
|
|
specified as backup location. This is particularly relevant for network
|
|
attached storage. If the problem persists, contact Technical Support."
|
|
::= { struxureWareOperationsStatus 4 }
|
|
|
|
etlStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
running(2),
|
|
failed(3),
|
|
paused(4),
|
|
stopped(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the StruxureWare Operations ETL services:
|
|
1: Unknown status. Check the network configuration and the server
|
|
network settings. If the problem persists, contact
|
|
Technical Support (http://www.apc.com/go/direct/index.cfm?tag=support).
|
|
2: Normal status,
|
|
3: ETL Transformations have failed and are subsequently stopped.
|
|
Investigate the cause of the failure. If the problem persists, contact
|
|
Technical Support (http://www.apc.com/go/direct/index.cfm?tag=support).
|
|
4: ETL Transformations are currently paused.
|
|
5: ETL Transformations are currently stopped."
|
|
::= { struxureWareOperationsStatus 5 }
|
|
|
|
-- the ups group
|
|
-- the upsIdent group
|
|
-- the upsBasicIdent
|
|
|
|
upsBasicIdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS model name (e.g. 'APC Smart-UPS 600')."
|
|
::= { upsBasicIdent 1 }
|
|
|
|
upsBasicIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An 8 byte ID string identifying the UPS. This object
|
|
can be set by the administrator."
|
|
::= { upsBasicIdent 2 }
|
|
|
|
|
|
-- the upsAdvIdent group
|
|
|
|
upsAdvIdentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the UPS system's microprocessor."
|
|
::= { upsAdvIdent 1 }
|
|
|
|
upsAdvIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the UPS was manufactured in mm/dd/yy (or yyyy) format."
|
|
::= { upsAdvIdent 2 }
|
|
|
|
upsAdvIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An 8-character string identifying the serial number of
|
|
the UPS internal microprocessor. This number is set at
|
|
the factory. NOTE: This number does NOT correspond to
|
|
the serial number on the rear of the UPS."
|
|
::= { upsAdvIdent 3 }
|
|
|
|
upsAdvIdentFirmwareRevision2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of a UPS system co-microprocessor."
|
|
::= { upsAdvIdent 4 }
|
|
|
|
upsAdvIdentSkuNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The SKU number of a UPS system."
|
|
::= { upsAdvIdent 5 }
|
|
|
|
-- the upsBattery group
|
|
-- the upsBasicBattery group
|
|
|
|
upsBasicBatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryInFaultCondition(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the UPS batteries. A batteryLow(3) value
|
|
indicates the UPS will be unable to sustain the current
|
|
load, and its services will be lost if power is not restored.
|
|
The amount of run time in reserve at the time of low battery
|
|
can be configured by the upsAdvConfigLowBatteryRunTime.
|
|
A batteryInFaultCondition(4)value indicates that a battery
|
|
installed has an internal error condition."
|
|
::= { upsBasicBattery 1 }
|
|
|
|
upsBasicBatteryTimeOnBattery OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The elapsed time since the UPS has switched to battery
|
|
power."
|
|
::= { upsBasicBattery 2 }
|
|
|
|
upsBasicBatteryLastReplaceDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the UPS system's batteries were last replaced
|
|
in mm/dd/yy (or yyyy) format. For Smart-UPS models, this value
|
|
is originally set in the factory. When the UPS batteries
|
|
are replaced, this value should be reset by the administrator.
|
|
For Symmetra PX 250/500 this OID is read only and is configurable in the local display only."
|
|
::= { upsBasicBattery 3 }
|
|
|
|
-- the upsAdvBattery group
|
|
|
|
upsAdvBatteryCapacity OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The remaining battery capacity expressed in
|
|
percent of full capacity."
|
|
::= { upsAdvBattery 1 }
|
|
|
|
upsAdvBatteryTemperature OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current internal UPS temperature expressed in
|
|
Celsius."
|
|
::= { upsAdvBattery 2 }
|
|
|
|
upsAdvBatteryRunTimeRemaining OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS battery run time remaining before battery
|
|
exhaustion."
|
|
::= { upsAdvBattery 3 }
|
|
|
|
upsAdvBatteryReplaceIndicator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noBatteryNeedsReplacing(1),
|
|
batteryNeedsReplacing(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the UPS batteries need replacing."
|
|
::= { upsAdvBattery 4 }
|
|
|
|
upsAdvBatteryNumOfBattPacks OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of external battery packs connected to the UPS. If
|
|
the UPS does not use smart cells then the agent reports
|
|
ERROR_NO_SUCH_NAME."
|
|
::= { upsAdvBattery 5 }
|
|
|
|
upsAdvBatteryNumOfBadBattPacks OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of external battery packs connected to the UPS that
|
|
are defective. If the UPS does not use smart cells then the
|
|
agent reports ERROR_NO_SUCH_NAME."
|
|
::= { upsAdvBattery 6 }
|
|
|
|
upsAdvBatteryNominalVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal battery voltage in Volts."
|
|
::= { upsAdvBattery 7 }
|
|
|
|
upsAdvBatteryActualVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual battery bus voltage in Volts."
|
|
::= { upsAdvBattery 8 }
|
|
|
|
upsAdvBatteryCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery current in Amps."
|
|
::= { upsAdvBattery 9 }
|
|
|
|
upsAdvTotalDCCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total DC current in Amps."
|
|
::= { upsAdvBattery 10 }
|
|
|
|
upsAdvBatteryFullCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The full chargeable capacity of the battery which is
|
|
expressed in percentage."
|
|
::= { upsAdvBattery 11 }
|
|
|
|
-- Advanced Battery Voltage Table
|
|
|
|
upsAdvBatteryActualVoltageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UPSAdvBatteryActualVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of battery table entries. The number of battery
|
|
frames present in UPS."
|
|
::= { upsAdvBattery 12 }
|
|
|
|
|
|
upsAdvBatteryActualVoltageEntry OBJECT-TYPE
|
|
SYNTAX UPSAdvBatteryActualVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Information applicable to
|
|
each of the Battery frames."
|
|
INDEX { upsAdvBatteryActualVoltageTableIndex }
|
|
::= { upsAdvBatteryActualVoltageTable 1 }
|
|
|
|
UPSAdvBatteryActualVoltageEntry ::= SEQUENCE {
|
|
upsAdvBatteryActualVoltageTableIndex INTEGER,
|
|
upsAdvBatteryActualVoltagePolarity INTEGER,
|
|
upsAdvBatteryFrameActualVoltage INTEGER
|
|
}
|
|
|
|
upsAdvBatteryActualVoltageTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Battery Frame identifier. Battery Frame index."
|
|
::= { upsAdvBatteryActualVoltageEntry 1 }
|
|
|
|
upsAdvBatteryActualVoltagePolarity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive (0),
|
|
negative (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The selected Battery Voltage Polarity.
|
|
0 indicates positive polarity.
|
|
1 indicates negative polarity."
|
|
::= { upsAdvBatteryActualVoltageEntry 2 }
|
|
|
|
upsAdvBatteryFrameActualVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual battery bus voltage in Volts."
|
|
::= { upsAdvBatteryActualVoltageEntry 3 }
|
|
|
|
-- Advanced TotalDC Current Table
|
|
|
|
upsAdvTotalDCCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UPSAdvTotalDCCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of Battery Frame table entries. The number of entries
|
|
is given by the value of Number of Battery Frames."
|
|
::= { upsAdvBattery 13 }
|
|
|
|
|
|
upsAdvTotalDCCurrentEntry OBJECT-TYPE
|
|
SYNTAX UPSAdvTotalDCCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular Battery Frame."
|
|
INDEX { upsAdvTotalDCCurrentTableIndex }
|
|
::= { upsAdvTotalDCCurrentTable 1 }
|
|
|
|
UPSAdvTotalDCCurrentEntry ::= SEQUENCE {
|
|
upsAdvTotalDCCurrentTableIndex INTEGER,
|
|
upsAdvTotalDCCurrentPolarity INTEGER,
|
|
upsAdvTotalFrameDCCurrent INTEGER
|
|
}
|
|
|
|
upsAdvTotalDCCurrentTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Battery Frame identifier. Total DC Current
|
|
Table Index."
|
|
::= { upsAdvTotalDCCurrentEntry 1 }
|
|
|
|
upsAdvTotalDCCurrentPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive (0),
|
|
negative (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The selected Battery Current Polarity.
|
|
0 indicates positive polarity.
|
|
1 indicates negative polarity."
|
|
::= { upsAdvTotalDCCurrentEntry 2 }
|
|
|
|
upsAdvTotalFrameDCCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The Total DC Current of battery in Amperes."
|
|
::= { upsAdvTotalDCCurrentEntry 3 }
|
|
|
|
|
|
|
|
-- Advanced Battery Current Table
|
|
|
|
upsAdvBatteryCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UPSAdvBatteryCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of Battery Frame table entries. The number of entries
|
|
is given by number of Battery frames present."
|
|
::= { upsAdvBattery 14 }
|
|
|
|
upsAdvBatteryCurrentEntry OBJECT-TYPE
|
|
SYNTAX UPSAdvBatteryCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular battery frame."
|
|
INDEX { upsAdvBatteryCurrentTableIndex, upsAdvBatteryCurrentIndex }
|
|
::= { upsAdvBatteryCurrentTable 1 }
|
|
|
|
UPSAdvBatteryCurrentEntry ::= SEQUENCE {
|
|
upsAdvBatteryCurrentTableIndex INTEGER,
|
|
upsAdvBatteryCurrentIndex INTEGER,
|
|
upsAdvBatteryCurrentPolarity INTEGER,
|
|
upsAdvBatteryFrameCurrent INTEGER
|
|
}
|
|
|
|
upsAdvBatteryCurrentTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Battery Frame identifier. Battery Current
|
|
Table Index."
|
|
::= { upsAdvBatteryCurrentEntry 1 }
|
|
|
|
upsAdvBatteryCurrentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery frame identifier."
|
|
::= { upsAdvBatteryCurrentEntry 2 }
|
|
|
|
upsAdvBatteryCurrentPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive (0),
|
|
negative (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The selected Battery current polarity.
|
|
0 indicates positive polarity.
|
|
1 indicates negative polarity"
|
|
::= { upsAdvBatteryCurrentEntry 3 }
|
|
|
|
upsAdvBatteryFrameCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Battery current measured in Amperes"
|
|
::= { upsAdvBatteryCurrentEntry 4 }
|
|
|
|
|
|
upsAdvBatteryEstimatedChargeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The estimated remaining time required to charge the UPS to a full state of charge."
|
|
::= { upsAdvBattery 15 }
|
|
|
|
upsAdvBatteryPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The measured battery power in kW."
|
|
::= { upsAdvBattery 16 }
|
|
|
|
upsAdvBatteryChargerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
ok(2),
|
|
inFaultCondition(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the battery charger. If the UPS is unable
|
|
to find the state of charger, this variable is set to unknown(1)."
|
|
::= { upsAdvBattery 17 }
|
|
|
|
|
|
upsAdvBatteryInternalSKU OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The SKU of the internal battery."
|
|
::= { upsAdvBattery 19 }
|
|
|
|
upsAdvBatteryExternalSKU OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The SKU of the external battery."
|
|
::= { upsAdvBattery 20 }
|
|
|
|
upsAdvBatteryRecommendedReplaceDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The recommended replacement date for the battery based on the UPS internal battery life algorithm."
|
|
::= { upsAdvBattery 21 }
|
|
|
|
|
|
-- the upsHighPrecBattery group
|
|
|
|
upsHighPrecBatteryCapacity OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The remaining battery capacity expressed in
|
|
tenths of percent of full capacity."
|
|
::= { upsHighPrecBattery 1 }
|
|
|
|
upsHighPrecBatteryTemperature OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current internal UPS temperature expressed in
|
|
tenths of degrees Celsius."
|
|
::= { upsHighPrecBattery 2 }
|
|
|
|
upsHighPrecBatteryNominalVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal battery voltage in tenths of Volts."
|
|
::= { upsHighPrecBattery 3 }
|
|
|
|
upsHighPrecBatteryActualVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual battery bus voltage in tenths of Volts."
|
|
::= { upsHighPrecBattery 4 }
|
|
|
|
upsHighPrecBatteryCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery current in tenths of Amps."
|
|
::= { upsHighPrecBattery 5 }
|
|
|
|
upsHighPrecTotalDCCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total DC current in tenths of Amps."
|
|
::= { upsHighPrecBattery 6 }
|
|
|
|
|
|
|
|
|
|
-- High Precision Actual Battery Voltage Table
|
|
|
|
upsHighPrecBatteryActualVoltageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UPSHighPrecBatteryActualVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of Battery frame table entries. The number of entries
|
|
is given by the number of Battery frames."
|
|
::= { upsHighPrecBattery 7 }
|
|
|
|
|
|
upsHighPrecBatteryActualVoltageEntry OBJECT-TYPE
|
|
SYNTAX UPSHighPrecBatteryActualVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular battery frame."
|
|
INDEX { upsHighPrecBatteryActualVoltageTableIndex }
|
|
::= { upsHighPrecBatteryActualVoltageTable 1 }
|
|
|
|
UPSHighPrecBatteryActualVoltageEntry ::= SEQUENCE {
|
|
upsHighPrecBatteryActualVoltageTableIndex INTEGER,
|
|
upsHighPrecBatteryActualVoltagePolarity INTEGER,
|
|
upsHighPrecBatteryVoltage INTEGER
|
|
}
|
|
|
|
upsHighPrecBatteryActualVoltageTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Battery Frame identifier. High Precision
|
|
Actual Voltage Table Index."
|
|
::= { upsHighPrecBatteryActualVoltageEntry 1 }
|
|
|
|
upsHighPrecBatteryActualVoltagePolarity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive (0),
|
|
negative (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The selected Battery Voltage polarity.
|
|
0 indicates positive polarity.
|
|
1 indicates negative polarity."
|
|
::= { upsHighPrecBatteryActualVoltageEntry 2 }
|
|
|
|
upsHighPrecBatteryVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual battery bus voltage expressed
|
|
as tenths of Volts. "
|
|
::= { upsHighPrecBatteryActualVoltageEntry 3 }
|
|
|
|
-- High Precision Total DC Current Table
|
|
|
|
upsHighPrecTotalDCCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UPSHighPrecTotalDCCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of Battery Frame table entries. The number of entries
|
|
is given by the number of battery frames."
|
|
::= { upsHighPrecBattery 8 }
|
|
|
|
|
|
upsHighPrecTotalDCCurrentEntry OBJECT-TYPE
|
|
SYNTAX UPSHighPrecTotalDCCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular battery frame."
|
|
INDEX { upsHighPrecTotalDCCurrentTableIndex }
|
|
::= { upsHighPrecTotalDCCurrentTable 1 }
|
|
|
|
UPSHighPrecTotalDCCurrentEntry ::= SEQUENCE {
|
|
upsHighPrecTotalDCCurrentTableIndex INTEGER,
|
|
upsHighPrecTotalDCCurrentPolarity INTEGER,
|
|
upsHighPrecTotalDCFrameCurrent INTEGER
|
|
}
|
|
|
|
upsHighPrecTotalDCCurrentTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Battery Frame identifier.
|
|
High precision Total DC Current index."
|
|
::= { upsHighPrecTotalDCCurrentEntry 1 }
|
|
|
|
upsHighPrecTotalDCCurrentPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive (0),
|
|
negative (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The selected Battery Current polarity.
|
|
0 indicates positive polarity.
|
|
1 indicates negative polarity."
|
|
::= { upsHighPrecTotalDCCurrentEntry 2 }
|
|
|
|
upsHighPrecTotalDCFrameCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total DC current in tenths of Amperes. "
|
|
::= { upsHighPrecTotalDCCurrentEntry 3 }
|
|
|
|
|
|
-- HighPrec Battery Current Table
|
|
|
|
upsHighPrecBatteryCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UPSHighPrecBatteryCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of Battery Frame table entries. The number of entries
|
|
is given by the number of battery frames."
|
|
::= { upsHighPrecBattery 9 }
|
|
|
|
upsHighPrecBatteryCurrentEntry OBJECT-TYPE
|
|
SYNTAX UPSHighPrecBatteryCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular battery frame."
|
|
INDEX { upsHighPrecBatteryCurrentTableIndex, upsHighPrecBatteryCurrentIndex }
|
|
::= { upsHighPrecBatteryCurrentTable 1 }
|
|
|
|
UPSHighPrecBatteryCurrentEntry ::= SEQUENCE {
|
|
upsHighPrecBatteryCurrentTableIndex INTEGER,
|
|
upsHighPrecBatteryCurrentIndex INTEGER,
|
|
upsHighPrecBatteryCurrentPolarity INTEGER,
|
|
upsHighPrecBatteryFrameCurrent INTEGER
|
|
}
|
|
|
|
upsHighPrecBatteryCurrentTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Battery frame identifier.
|
|
Battery Frame index."
|
|
::= { upsHighPrecBatteryCurrentEntry 1 }
|
|
|
|
upsHighPrecBatteryCurrentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Battery frame identifier.
|
|
Battery Index for each frame."
|
|
::= { upsHighPrecBatteryCurrentEntry 2 }
|
|
|
|
upsHighPrecBatteryCurrentPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive (0),
|
|
negative (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The selected Battery Current polarity.
|
|
0 indicates positive polarity.
|
|
1 indicates negative polarity."
|
|
::= { upsHighPrecBatteryCurrentEntry 3 }
|
|
|
|
upsHighPrecBatteryFrameCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Battery current in tenths of Amperes."
|
|
::= { upsHighPrecBatteryCurrentEntry 4 }
|
|
|
|
-- High Precision Battery Packs
|
|
|
|
upsHighPrecBatteryPacks OBJECT IDENTIFIER ::= { upsHighPrecBattery 10 }
|
|
|
|
upsHighPrecBatteryPackTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the upsHighPrecBatteryPacks."
|
|
::= { upsHighPrecBatteryPacks 1 }
|
|
|
|
upsHighPrecBatteryPackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UPSHighPrecBatteryPackEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of Battery Pack table entries. The number of entries
|
|
is given by number of Battery Packs present."
|
|
::= { upsHighPrecBatteryPacks 2 }
|
|
|
|
upsHighPrecBatteryPackEntry OBJECT-TYPE
|
|
SYNTAX UPSHighPrecBatteryPackEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular battery pack."
|
|
INDEX { upsHighPrecBatteryPackIndex, upsHighPrecBatteryCartridgeIndex }
|
|
::= { upsHighPrecBatteryPackTable 1 }
|
|
|
|
UPSHighPrecBatteryPackEntry ::= SEQUENCE {
|
|
upsHighPrecBatteryPackIndex INTEGER,
|
|
upsHighPrecBatteryCartridgeIndex INTEGER,
|
|
upsHighPrecBatteryPackFirmwareRevision DisplayString,
|
|
upsHighPrecBatteryPackSerialNumber DisplayString,
|
|
upsHighPrecBatteryPackTemperature INTEGER,
|
|
upsHighPrecBatteryPackStatus OCTET STRING,
|
|
upsHighPrecBatteryPackCartridgeHealth OCTET STRING,
|
|
upsHighPrecBatteryPackCartridgeReplaceDate DisplayString,
|
|
upsHighPrecBatteryPackCartridgeInstallDate DisplayString,
|
|
upsHighPrecBatteryPackCartridgeStatus OCTET STRING
|
|
}
|
|
|
|
upsHighPrecBatteryPackIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery pack identifier."
|
|
::= { upsHighPrecBatteryPackEntry 1 }
|
|
|
|
upsHighPrecBatteryCartridgeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery cartridge identifier."
|
|
::= { upsHighPrecBatteryPackEntry 2 }
|
|
|
|
upsHighPrecBatteryPackFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery pack firmware revision."
|
|
::= { upsHighPrecBatteryPackEntry 3}
|
|
|
|
upsHighPrecBatteryPackSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery pack serial number."
|
|
::= { upsHighPrecBatteryPackEntry 4}
|
|
|
|
upsHighPrecBatteryPackTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery pack temperature measured in 10ths of degree Celcius"
|
|
::= { upsHighPrecBatteryPackEntry 5 }
|
|
|
|
upsHighPrecBatteryPackStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery status for the pack only.
|
|
bit 0 Disconnected
|
|
bit 1 Overvoltage
|
|
bit 2 NeedsReplacement
|
|
bit 3 OvertemperatureCritical
|
|
bit 4 Charger
|
|
bit 5 TemperatureSensor
|
|
bit 6 BusSoftStart
|
|
bit 7 OvertemperatureWarning
|
|
bit 8 GeneralError
|
|
bit 9 Communication
|
|
bit 10 DisconnectedFrame
|
|
bit 11 FirmwareMismatch
|
|
"
|
|
::= { upsHighPrecBatteryPackEntry 6 }
|
|
|
|
upsHighPrecBatteryPackCartridgeHealth OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery cartridge health.
|
|
bit 0 Battery lifetime okay
|
|
bit 1 Battery lifetime near end, order replacement cartridge
|
|
bit 2 Battery lifetime exceeded, replace battery
|
|
bit 3 Battery lifetime near end acknowledged, order replacement cartridge
|
|
bit 4 Battery lifetime exceeded acknowledged, replace battery
|
|
bit 5 Battery measured lifetime near end, order replacement cartridge
|
|
bit 6 Battery measured lifetime near end acknowledged, order replacement cartridge
|
|
"
|
|
::= { upsHighPrecBatteryPackEntry 7}
|
|
|
|
upsHighPrecBatteryPackCartridgeReplaceDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery cartridge estimated battery replace date."
|
|
::= { upsHighPrecBatteryPackEntry 8 }
|
|
|
|
upsHighPrecBatteryPackCartridgeInstallDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery cartridge install date."
|
|
::= { upsHighPrecBatteryPackEntry 9 }
|
|
|
|
upsHighPrecBatteryPackCartridgeStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery cartridge status.
|
|
bit 0 Disconnected
|
|
bit 1 Overvoltage
|
|
bit 2 NeedsReplacement
|
|
bit 3 OvertemperatureCritical
|
|
bit 4 Charger
|
|
bit 5 TemperatureSensor
|
|
bit 6 BusSoftStart
|
|
bit 7 OvertemperatureWarning
|
|
bit 8 GeneralError
|
|
bit 9 Communication
|
|
bit 10 DisconnectedFrame
|
|
bit 11 FirmwareMismatch
|
|
"
|
|
::= { upsHighPrecBatteryPackEntry 10 }
|
|
|
|
-- the upsBasicInput group
|
|
|
|
upsBasicInputPhase OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current AC input phase."
|
|
::= { upsBasicInput 1 }
|
|
|
|
|
|
-- the upsAdvInput group
|
|
|
|
upsAdvInputLineVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current utility line voltage in VAC."
|
|
::= { upsAdvInput 1 }
|
|
|
|
upsAdvInputMaxLineVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum utility line voltage in VAC over the
|
|
previous 1 minute period."
|
|
::= { upsAdvInput 2 }
|
|
|
|
upsAdvInputMinLineVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum utility line voltage in VAC over the
|
|
previous 1 minute period."
|
|
::= { upsAdvInput 3 }
|
|
|
|
upsAdvInputFrequency OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current input frequency to the UPS system in Hz."
|
|
::= { upsAdvInput 4 }
|
|
|
|
|
|
upsAdvInputLineFailCause OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTransfer(1),
|
|
highLineVoltage(2),
|
|
brownout(3),
|
|
blackout(4),
|
|
smallMomentarySag(5),
|
|
deepMomentarySag(6),
|
|
smallMomentarySpike(7),
|
|
largeMomentarySpike(8),
|
|
selfTest(9),
|
|
rateOfVoltageChange(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The reason for the occurrence of the last transfer to UPS
|
|
battery power. The variable is set to:
|
|
- noTransfer(1) -- if there is no transfer yet.
|
|
- highLineVoltage(2) -- if the transfer to battery is caused
|
|
by an over voltage greater than the high transfer voltage.
|
|
- brownout(3) -- if the duration of the outage is greater than
|
|
five seconds and the line voltage is between 40% of the
|
|
rated output voltage and the low transfer voltage.
|
|
- blackout(4) -- if the duration of the outage is greater than five
|
|
seconds and the line voltage is between 40% of the rated
|
|
output voltage and ground.
|
|
- smallMomentarySag(5) -- if the duration of the outage is less
|
|
than five seconds and the line voltage is between 40% of the
|
|
rated output voltage and the low transfer voltage.
|
|
- deepMomentarySag(6) -- if the duration of the outage is less
|
|
than five seconds and the line voltage is between 40% of the
|
|
rated output voltage and ground. The variable is set to
|
|
- smallMomentarySpike(7) -- if the line failure is caused by a
|
|
rate of change of input voltage less than ten volts per cycle.
|
|
- largeMomentarySpike(8) -- if the line failure is caused by
|
|
a rate of change of input voltage greater than ten volts per cycle.
|
|
- selfTest(9) -- if the UPS was commanded to do a self test.
|
|
- rateOfVoltageChange(10) -- if the failure is due to the rate of change of
|
|
the line voltage."
|
|
::= { upsAdvInput 5 }
|
|
|
|
|
|
upsAdvInputNominalFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal input frequency of the UPS system in Hz."
|
|
::= { upsAdvInput 6 }
|
|
|
|
upsAdvInputNominalVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal input voltage of the UPS system in VAC."
|
|
::= { upsAdvInput 7 }
|
|
|
|
upsAdvInputBypassNominalFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal bypass input frequency of the UPS system in Hz."
|
|
::= { upsAdvInput 8 }
|
|
|
|
upsAdvInputBypassNominalVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal bypass input voltage of the UPS system in VAC."
|
|
::= { upsAdvInput 9 }
|
|
|
|
upsAdvInputStatisticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsAdvInputStatisticsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of upsPhaseNumInputs."
|
|
::= { upsAdvInput 10 }
|
|
|
|
upsAdvInputStatisticsEntry OBJECT-TYPE
|
|
SYNTAX UpsAdvInputStatisticsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input."
|
|
INDEX { upsAdvInputStatisticsIndex }
|
|
::= { upsAdvInputStatisticsTable 1 }
|
|
|
|
UpsAdvInputStatisticsEntry ::= SEQUENCE {
|
|
upsAdvInputStatisticsIndex INTEGER,
|
|
upsAdvInputApparentPower INTEGER,
|
|
upsAdvInputVoltageTHD INTEGER,
|
|
upsAdvInputBypassVoltageTHD INTEGER,
|
|
upsAdvInputPeakCurrent INTEGER,
|
|
upsAdvInputBypassPeakCurrent INTEGER,
|
|
upsAdvInputActivePower INTEGER
|
|
}
|
|
|
|
upsAdvInputStatisticsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input identifier."
|
|
::= { upsAdvInputStatisticsEntry 1 }
|
|
|
|
upsAdvInputApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input apparent power(sum of all of the three phases) measured in kVA."
|
|
::= { upsAdvInputStatisticsEntry 2 }
|
|
|
|
upsAdvInputVoltageTHD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input voltage Total Harmonic Distortion in percent."
|
|
::= { upsAdvInputStatisticsEntry 3 }
|
|
|
|
upsAdvInputBypassVoltageTHD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bypass input voltage Total Harmonic Distortion in percent."
|
|
::= { upsAdvInputStatisticsEntry 4 }
|
|
|
|
upsAdvInputPeakCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input peak current in Amperes."
|
|
::= { upsAdvInputStatisticsEntry 5 }
|
|
|
|
upsAdvInputBypassPeakCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bypass input peak current in Amperes."
|
|
::= { upsAdvInputStatisticsEntry 6 }
|
|
|
|
|
|
upsAdvInputActivePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input active power measured in kW."
|
|
::= { upsAdvInputStatisticsEntry 7 }
|
|
|
|
|
|
|
|
|
|
upsAdvInputTotalApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input total apparent power(sum of all three phases)
|
|
of the UPS system in kVA."
|
|
::= { upsAdvInput 11 }
|
|
|
|
upsAdvInputTotalActivePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input total active power(sum of all three phases)
|
|
of the UPS system in kW."
|
|
::= { upsAdvInput 12 }
|
|
|
|
upsAdvInputBypassTotalApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input bypass total apparent power(sum of all three phases)
|
|
of the UPS system in kVA."
|
|
::= { upsAdvInput 13 }
|
|
|
|
upsAdvInputBypassTotalActivePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input bypass total active power(sum of all three phases)
|
|
of the UPS system in kW."
|
|
::= { upsAdvInput 14 }
|
|
|
|
|
|
-- the upsHighPrecInput group
|
|
|
|
upsHighPrecInputLineVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current utility line voltage in tenths of VAC."
|
|
::= { upsHighPrecInput 1 }
|
|
|
|
upsHighPrecInputMaxLineVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum utility line voltage in tenths of VAC over the
|
|
previous 1 minute period."
|
|
::= { upsHighPrecInput 2 }
|
|
|
|
upsHighPrecInputMinLineVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum utility line voltage in tenths of VAC over the
|
|
previous 1 minute period."
|
|
::= { upsHighPrecInput 3 }
|
|
|
|
upsHighPrecInputFrequency OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current input frequency to the UPS system in tenths of Hz."
|
|
::= { upsHighPrecInput 4 }
|
|
|
|
|
|
upsHighPrecInputEnergyUsage OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input energy usage of the UPS in hundredths of kWh."
|
|
::= { upsHighPrecInput 5 }
|
|
|
|
upsHighPrecInputBypassVoltage OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current bypass line voltage in tenths of VAC."
|
|
::= { upsHighPrecInput 6 }
|
|
|
|
upsHighPrecInputBypassFrequency OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current input bypass frequency to the UPS system in tenths of Hz."
|
|
::= { upsHighPrecInput 7 }
|
|
|
|
-- the upsBasicOutput group
|
|
|
|
upsBasicOutputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
onLine(2),
|
|
onBattery(3),
|
|
onSmartBoost(4),
|
|
timedSleeping(5),
|
|
softwareBypass(6),
|
|
off(7),
|
|
rebooting(8),
|
|
switchedBypass(9),
|
|
hardwareFailureBypass(10),
|
|
sleepingUntilPowerReturn(11),
|
|
onSmartTrim(12),
|
|
ecoMode(13),
|
|
hotStandby(14),
|
|
onBatteryTest(15),
|
|
emergencyStaticBypass(16),
|
|
staticBypassStandby(17),
|
|
powerSavingMode(18),
|
|
spotMode(19),
|
|
eConversion(20),
|
|
chargerSpotmode(21),
|
|
inverterSpotmode(22)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of the UPS. If the UPS is unable to
|
|
determine the state of the UPS this variable is set
|
|
to unknown(1)."
|
|
::= { upsBasicOutput 1 }
|
|
|
|
upsBasicOutputPhase OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current output phase."
|
|
::= { upsBasicOutput 2 }
|
|
|
|
upsBasicSystemStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
onLine(2),
|
|
onBattery(3),
|
|
onSmartBoost(4),
|
|
timedSleeping(5),
|
|
softwareBypass(6),
|
|
off(7),
|
|
rebooting(8),
|
|
switchedBypass(9),
|
|
hardwareFailureBypass(10),
|
|
sleepingUntilPowerReturn(11),
|
|
onSmartTrim(12),
|
|
ecoMode(13),
|
|
inverter(14),
|
|
eConversion(15),
|
|
staticBypassStandby(16)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current state for the whole system (UPS and surrounding breakers).
|
|
If the UPS is unable to determine the state of the system, this
|
|
variable is set to unknown(1)."
|
|
::= { upsBasicOutput 3 }
|
|
|
|
upsBasicSystemInternalTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual internal temperature of the UPS system in Celsius."
|
|
::= { upsBasicOutput 4 }
|
|
|
|
|
|
upsBasicSystemInverterStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
ok(2),
|
|
inFaultCondition(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of the UPS inverter. If the UPS is unable
|
|
to determine the state of the inverter, this variable is set
|
|
to unknown(1)."
|
|
::= { upsBasicOutput 5 }
|
|
|
|
upsBasicSystemPFCStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
ok(2),
|
|
inFaultCondition(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The general status of the power factor correction (AC input stage
|
|
of the UPS). If the UPS is unable to determine the state of PFC,
|
|
this variable is set to unknown(1)."
|
|
::= { upsBasicOutput 6 }
|
|
|
|
upsBasicOutputACwiringConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
noNeutralWiredonSystem(2),
|
|
neutralUsedforSupplyingLoad(3)
|
|
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if neutral wire on output side of the UPS is
|
|
used (load wired line to neutral). If the UPS is unable to
|
|
determine the state of neutral, this variable is set to
|
|
unknown(1)."
|
|
::= { upsBasicOutput 7 }
|
|
|
|
|
|
|
|
-- the upsAdvOutput group
|
|
|
|
upsAdvOutputVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output voltage of the UPS system in VAC."
|
|
::= { upsAdvOutput 1 }
|
|
|
|
upsAdvOutputFrequency OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current output frequency of the UPS system in Hz."
|
|
::= { upsAdvOutput 2 }
|
|
|
|
upsAdvOutputLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current UPS load expressed in percent
|
|
of rated capacity."
|
|
::= { upsAdvOutput 3 }
|
|
|
|
upsAdvOutputCurrent OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current in amperes drawn by the load on the UPS."
|
|
::= { upsAdvOutput 4 }
|
|
|
|
upsAdvOutputRedundancy OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of power modules which can fail or be
|
|
removed without causing the UPS to generate a Minimum
|
|
Redundancy Lost event."
|
|
::= { upsAdvOutput 5 }
|
|
|
|
upsAdvOutputKVACapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum load that this UPS can support."
|
|
::= { upsAdvOutput 6 }
|
|
|
|
upsAdvOutputNominalFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal output frequency of the UPS system in Hz."
|
|
::= { upsAdvOutput 7 }
|
|
|
|
upsAdvOutputActivePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total output active power of the UPS system in W.
|
|
The total active power is the sum of phase 1, phase 2 and
|
|
phase 3 power."
|
|
::= { upsAdvOutput 8 }
|
|
|
|
upsAdvOutputApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total output apparent power of all phases of the UPS system in VA."
|
|
::= { upsAdvOutput 9 }
|
|
|
|
|
|
upsAdvOutputStatisticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsAdvOutputStatisticsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of upsPhaseNumOutputs."
|
|
::= { upsAdvOutput 10 }
|
|
|
|
upsAdvOutputStatisticsEntry OBJECT-TYPE
|
|
SYNTAX UpsAdvOutputStatisticsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output."
|
|
INDEX { upsAdvOutputStatisticsIndex }
|
|
::= { upsAdvOutputStatisticsTable 1 }
|
|
|
|
UpsAdvOutputStatisticsEntry ::= SEQUENCE {
|
|
upsAdvOutputStatisticsIndex INTEGER,
|
|
upsAdvOutputPeakCurrent INTEGER,
|
|
upsAdvOutputCurrentTHD INTEGER,
|
|
upsAdvOutputCrestFactor INTEGER
|
|
|
|
}
|
|
|
|
upsAdvOutputStatisticsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output identifier."
|
|
::= { upsAdvOutputStatisticsEntry 1 }
|
|
|
|
upsAdvOutputPeakCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output peak current in Amperes."
|
|
::= { upsAdvOutputStatisticsEntry 2 }
|
|
|
|
upsAdvOutputCurrentTHD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output current Total Harmonic Distortion in percent."
|
|
::= { upsAdvOutputStatisticsEntry 3 }
|
|
|
|
upsAdvOutputCrestFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output current crest factor expressed in tenths."
|
|
::= { upsAdvOutputStatisticsEntry 4 }
|
|
|
|
upsAdvOutputNeutralCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The neutral current in amperes."
|
|
::= { upsAdvOutput 11 }
|
|
|
|
|
|
-- the upsHighPrecOutput group
|
|
|
|
upsHighPrecOutputVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output voltage of the UPS system in tenths of VAC."
|
|
::= { upsHighPrecOutput 1 }
|
|
|
|
upsHighPrecOutputFrequency OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current output frequency of the UPS system in tenths of Hz."
|
|
::= { upsHighPrecOutput 2 }
|
|
|
|
upsHighPrecOutputLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current UPS load expressed in tenths of percent
|
|
of rated capacity."
|
|
::= { upsHighPrecOutput 3 }
|
|
|
|
upsHighPrecOutputCurrent OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current in tenths of amperes drawn by the load on the UPS."
|
|
::= { upsHighPrecOutput 4 }
|
|
|
|
upsHighPrecOutputEfficiency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The positive values represent efficiency of the UPS in tenths of percent.
|
|
-1 If UPS supports this OID but the result is not available
|
|
-2 Load is too low to report efficiency
|
|
-3 Output off and efficiency is 0
|
|
-4 On battery, efficiency is not measured or calculated in this mode
|
|
-5 In Bypass, efficiency is not measured or calculated in this mode
|
|
-6 Battery charging, battery is charging and adversely affecting efficiency
|
|
-7 Poor AC input, the main input is outside the optimum efficiency range"
|
|
::= { upsHighPrecOutput 5 }
|
|
|
|
upsHighPrecOutputEnergyUsage OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output energy usage of the UPS in hundredths of kWh."
|
|
::= { upsHighPrecOutput 6 }
|
|
|
|
-- the upsBasicConfig group
|
|
|
|
upsBasicConfigNumDevices OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of devices that are plugged into the UPS.
|
|
This value is customer configurable from the device entry table"
|
|
::= { upsBasicConfig 1 }
|
|
|
|
upsBasicConfigDeviceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsBasicConfigDeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of devices that are plugged into the UPS.
|
|
The number of entries is given by the value of
|
|
upsBasicConfigNumDevices."
|
|
::= { upsBasicConfig 2 }
|
|
|
|
upsBasicConfigDeviceEntry OBJECT-TYPE
|
|
SYNTAX UpsBasicConfigDeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The devices plugged in to the UPS."
|
|
INDEX { deviceIndex }
|
|
::= { upsBasicConfigDeviceTable 1 }
|
|
|
|
UpsBasicConfigDeviceEntry ::=
|
|
SEQUENCE {
|
|
deviceIndex
|
|
INTEGER,
|
|
deviceName
|
|
DisplayString,
|
|
vaRating
|
|
INTEGER,
|
|
acceptThisDevice
|
|
INTEGER
|
|
}
|
|
|
|
deviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the device that is plugged into the UPS."
|
|
::= { upsBasicConfigDeviceEntry 1 }
|
|
|
|
deviceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name/description of the device plugged into the UPS."
|
|
::= { upsBasicConfigDeviceEntry 2 }
|
|
|
|
vaRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The volt-amp rating of the device plugged into the UPS."
|
|
::= { upsBasicConfigDeviceEntry 3 }
|
|
|
|
acceptThisDevice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes(1),
|
|
no(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry is added if yes, the entry is deleted if no."
|
|
::= { upsBasicConfigDeviceEntry 4 }
|
|
|
|
|
|
|
|
|
|
-- the upsAdvConfig group
|
|
|
|
upsAdvConfigRatedOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal output voltage from the UPS in VAC.
|
|
|
|
For a list of allowed values supported by your UPS model,
|
|
see the UPS User's Manual.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the UPS interprets it as the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used."
|
|
::= { upsAdvConfig 1 }
|
|
|
|
upsAdvConfigHighTransferVolt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum line voltage in VAC allowed before the
|
|
UPS system transfers to battery backup.
|
|
|
|
For a list of allowed values supported by your UPS model,
|
|
see the UPS User's Manual.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the UPS interprets it as a the next higher
|
|
acceptable value. If the provided value is higher than
|
|
the highest acceptable value, the highest acceptable
|
|
value is used."
|
|
::= { upsAdvConfig 2 }
|
|
|
|
upsAdvConfigLowTransferVolt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum line voltage in VAC allowed before the
|
|
UPS system transfers to battery backup.
|
|
|
|
For a list of allowed values supported by your UPS model,
|
|
see the UPS User's Manual.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the UPS interprets it as the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used."
|
|
::= { upsAdvConfig 3 }
|
|
|
|
upsAdvConfigAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
timed(1),
|
|
atLowBattery(2),
|
|
never(3),
|
|
mute(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A flag indicating how the UPS should handle audible
|
|
line fail alarms:
|
|
timed(1): UPS alarm will sound after a preset timed duration starting
|
|
from the line fail condition (see OID upsAdvConfigAlarmTimer for the
|
|
alarm timer value)
|
|
atLowBattery(2): UPS alarm will sound when the UPS has reached a Low
|
|
Battery condition during a line fail
|
|
never(3): Disables the UPS audible alarm
|
|
mute(4): Mutes the current alarm for some UPSs only when it is in an
|
|
alarm state and will return to the previously configured option when
|
|
the UPS recovers from the alarm condition"
|
|
::= { upsAdvConfig 4 }
|
|
|
|
upsAdvConfigAlarmTimer OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time after initial line failure at which the UPS
|
|
begins emitting audible alarms (beeping). This timer is
|
|
observed only if the value of extControlAlarm is timed(2).
|
|
Allowed values are 0 or 30 seconds.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the UPS interprets it as a the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used."
|
|
::= { upsAdvConfig 5 }
|
|
|
|
upsAdvConfigMinReturnCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum battery capacity required before the UPS will
|
|
return from a low battery shutdown condition. The capacity is
|
|
measured from 0% battery capacity (or Low Battery) as a percent
|
|
of full capacity (100%). In other words, the UPS will not re-energize
|
|
the output until the battery has charged so that its' capacity is equal
|
|
to this value.
|
|
|
|
For a list of allowed values supported by your UPS model,
|
|
see the UPS User's Manual.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the UPS interprets it as a the next higher
|
|
acceptable value. If the provided value is higher than
|
|
the highest acceptable value, the highest acceptable
|
|
value is used."
|
|
::= { upsAdvConfig 6 }
|
|
|
|
upsAdvConfigSensitivity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto(1),
|
|
low(2),
|
|
medium(3),
|
|
high(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensitivity of the UPS to utility line abnormalities
|
|
or noises."
|
|
::= { upsAdvConfig 7 }
|
|
|
|
upsAdvConfigLowBatteryRunTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The desired run time of the UPS, in seconds, once the
|
|
low battery condition is reached. During this time the UPS will
|
|
produce a constant warning tone which can not be disabled.
|
|
|
|
For a list of allowed values supported by your UPS model,
|
|
see the UPS User's Manual.
|
|
|
|
If a value other than a supported value is provided in a set
|
|
request, the UPS interprets the value as the next higher
|
|
acceptable value. If the provided value is higher than the
|
|
highest acceptable value, the highest acceptable value is used."
|
|
::= { upsAdvConfig 8 }
|
|
|
|
upsAdvConfigReturnDelay OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay in seconds after utility line power returns
|
|
before the UPS will turn on. This value is also used
|
|
when the UPS comes out of a reboot and before the UPS
|
|
wakes up from 'sleep' mode.
|
|
|
|
For a list of allowed values supported by your UPS model,
|
|
see the UPS User's Manual.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the UPS interprets it as a the next higher
|
|
acceptable value. If the provided value is higher than
|
|
the highest acceptable value, the highest acceptable
|
|
value is used."
|
|
::= { upsAdvConfig 9 }
|
|
|
|
upsAdvConfigShutoffDelay OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay in seconds the UPS remains on after being told
|
|
to turn off.
|
|
|
|
For a list of allowed values supported by your UPS model,
|
|
see the UPS User's Manual.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the UPS interprets it as a the next higher
|
|
acceptable value. If the provided value is higher than
|
|
the highest acceptable value, the highest acceptable
|
|
value is used."
|
|
::= { upsAdvConfig 10 }
|
|
|
|
upsAdvConfigUpsSleepTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time in seconds for the UPS to go to 'sleep' when
|
|
instructed. When in sleep mode, the UPS will not provide
|
|
output power regardless of the input line state. Once the
|
|
specified time has elapsed, output power will be restored.
|
|
|
|
This is a configuration setting. The UPS will not go to
|
|
sleep until told to do so by the manager from a management
|
|
station.
|
|
|
|
Any input value is allowed, however the UPS only recognizes
|
|
1/10 of an hour increments. The provided value will be
|
|
rounded to the closest 1/10 of an hour with one exception:
|
|
Any value entered between 1 and 540 seconds will be rounded
|
|
to 360 seconds (or 6 minutes)."
|
|
::= { upsAdvConfig 11 }
|
|
|
|
|
|
upsAdvConfigSetEEPROMDefaults OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noSetEEPROMDefaults(1),
|
|
setEEPROMDefaults(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"WRITE: Resets the UPS EEPROM variables to default values.
|
|
READ: returns 1"
|
|
::= { upsAdvConfig 12 }
|
|
|
|
upsAdvConfigDipSwitchTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsAdvConfigDipSwitchEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current settings of UPS dip switches."
|
|
::= { upsAdvConfig 13 }
|
|
|
|
upsAdvConfigDipSwitchEntry OBJECT-TYPE
|
|
SYNTAX UpsAdvConfigDipSwitchEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current setting of one dip switch."
|
|
INDEX { dipSwitchIndex }
|
|
::= { upsAdvConfigDipSwitchTable 1 }
|
|
|
|
UpsAdvConfigDipSwitchEntry ::=
|
|
SEQUENCE {
|
|
dipSwitchIndex
|
|
INTEGER,
|
|
dipSwitchStatus
|
|
INTEGER
|
|
}
|
|
|
|
dipSwitchIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of a UPS dip switch."
|
|
::= { upsAdvConfigDipSwitchEntry 1 }
|
|
|
|
dipSwitchStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The setting of a UPS dip switch."
|
|
::= { upsAdvConfigDipSwitchEntry 2 }
|
|
|
|
upsAdvConfigBattExhaustThresh OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of seconds prior to battery exhaustion when the
|
|
UPS will switch off power to its load."
|
|
::= { upsAdvConfig 14 }
|
|
|
|
upsAdvConfigPassword OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The password entered at the UPS front panel to enable local
|
|
configuration of the EEProm. If the password is disabled or
|
|
is not supported, then the agent returns a null string."
|
|
::= { upsAdvConfig 15 }
|
|
|
|
upsAdvConfigAllowedSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsAdvConfigAllowedSetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The table listing the allowed values for all discrete
|
|
configurable UPS variables."
|
|
::= { upsAdvConfig 16 }
|
|
|
|
upsAdvConfigAllowedSetEntry OBJECT-TYPE
|
|
SYNTAX UpsAdvConfigAllowedSetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The table entry for a configurable UPS variable."
|
|
INDEX { apcUpsConfigFieldIndex }
|
|
::= { upsAdvConfigAllowedSetTable 1 }
|
|
|
|
UpsAdvConfigAllowedSetEntry ::= SEQUENCE {
|
|
apcUpsConfigFieldIndex INTEGER,
|
|
apcUpsConfigFieldOID OBJECT IDENTIFIER,
|
|
apcUpsConfigFieldValueRange DisplayString
|
|
}
|
|
|
|
apcUpsConfigFieldIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to an eeprom field entry."
|
|
::= { upsAdvConfigAllowedSetEntry 1 }
|
|
|
|
apcUpsConfigFieldOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The OID of the current configurable value."
|
|
::= { upsAdvConfigAllowedSetEntry 2 }
|
|
|
|
apcUpsConfigFieldValueRange OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The discrete set of allowed values of a configurable
|
|
register. Individual values are delimited by a comma."
|
|
::= { upsAdvConfigAllowedSetEntry 3 }
|
|
|
|
upsAdvConfigBattCabAmpHour OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the amp-hour setting of the UPS battery cabinet."
|
|
::= { upsAdvConfig 17 }
|
|
|
|
upsAdvConfigPositionSelector OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
rack (2),
|
|
tower (3)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure UPS position selector. If the UPS doesn't
|
|
support this configuration it will report unknown (1).
|
|
The positions are either rack (2) for rack mounted or
|
|
tower (3) for tower unit."
|
|
::= { upsAdvConfig 18 }
|
|
|
|
upsAdvConfigOutputFreqRange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
freqRangeAUTO (2),
|
|
freqRange60Var1 (3),
|
|
freqRange60Var3 (4),
|
|
freqRange50Var1 (5),
|
|
freqRange50Var3 (6),
|
|
freqRange60Var10 (7),
|
|
freqRange50Var10 (8),
|
|
freqRange60Var1dot0 (9),
|
|
freqRange50Var1dot0 (10),
|
|
freqRange50Pct0dot5 (11),
|
|
freqRange50Pct1 (12),
|
|
freqRange50Pct2 (13),
|
|
freqRange50Pct4 (14),
|
|
freqRange50Pct6 (15),
|
|
freqRange50Pct8 (16),
|
|
freqRange60Pct0dot5 (17),
|
|
freqRange60Pct1 (18),
|
|
freqRange60Pct2 (19),
|
|
freqRange60Pct4 (20),
|
|
freqRange60Pct6 (21),
|
|
freqRange60Pct8 (22)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the output frequency tolerance range.
|
|
unknown(1) indicates the output frequency is unknown.
|
|
freqRangeAUTO(2) configure the output frequency range for automatic.
|
|
freqRange60Var1(3) configure the output frequency range for 60 +/- 0.1 Hz
|
|
freqRange60Var3(4) configure the output frequency range for 60 +/- 3.0 Hz
|
|
freqRange50Var1(5) configure the output frequency range for 50 +/- 0.1 Hz
|
|
freqRange50Var3(6) configure the output frequency range for 50 +/- 3.0 Hz
|
|
freqRange60Var10(7) configure the output frequency range for 60 +/- 10 Hz
|
|
freqRange50Var10(8) configure the output frequency range for 50 +/- 10 Hz
|
|
freqRange60Var1dot0(9) configure the output frequency range for 60 +/- 1.0 Hz
|
|
freqRange50Var1dot0(10) configure the output frequency range for 50 +/- 1.0 Hz
|
|
freqRange50Pct0dot5(11) configure the output frequency range for 50 Hz +/- 0.5 %
|
|
freqRange50Pct1(12) configure the output frequency range for 50 Hz +/- 1.0 %
|
|
freqRange50Pct2(13) configure the output frequency range for 50 Hz +/- 2.0 %
|
|
freqRange50Pct4(14) configure the output frequency range for 50 Hz +/- 4.0 %
|
|
freqRange50Pct6(15) configure the output frequency range for 50 Hz +/- 6.0 %
|
|
freqRange50Pct8(16) configure the output frequency range for 50 Hz +/- 8.0 %
|
|
freqRange60Pct0dot5(17) configure the output frequency range for 60 Hz +/- 0.5 %
|
|
freqRange60Pct1(18) configure the output frequency range for 60 Hz +/- 1.0 %
|
|
freqRange60Pct2(19) configure the output frequency range for 60 Hz +/- 2.0 %
|
|
freqRange60Pct4(20) configure the output frequency range for 60 Hz +/- 4.0 %
|
|
freqRange60Pct6(21) configure the output frequency range for 60 Hz +/- 6.0 %
|
|
freqRange60Pct8(22) configure the output frequency range for 60 Hz +/- 8.0 %
|
|
For a list of allowed values and conditions when variable can be set by your UPS model,
|
|
see the UPS User's Manual."
|
|
::= { upsAdvConfig 19 }
|
|
|
|
upsAdvConfigUPSFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
gotoBypass (2),
|
|
dropLoad (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the UPS fail action. If UPS fails,
|
|
and frequency or voltage is out of range it will either
|
|
GotoBypass (2) or DropLoad (3). This OID will report
|
|
unknown (1) if it is not supported feature or option."
|
|
::= { upsAdvConfig 20 }
|
|
|
|
upsAdvConfigAlarmRedundancy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure settings of UPS alarm if the redundancy is
|
|
under the current redundancy. Use 0 for never."
|
|
::= { upsAdvConfig 21 }
|
|
|
|
upsAdvConfigAlarmLoadOver OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure settings of UPS alarm if the load is
|
|
over the current load in kVA. Use -1 for never."
|
|
::= { upsAdvConfig 22 }
|
|
|
|
upsAdvConfigAlarmRuntimeUnder OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure settings of UPS alarm if the runtime is
|
|
under the current time of minutes. Use -1 for never."
|
|
::= { upsAdvConfig 23 }
|
|
|
|
upsAdvConfigVoutReporting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
voutAUTO (2),
|
|
vout208 (3),
|
|
vout240 (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the way the UPS scales its output voltage readings.
|
|
unknown(1) indicates the Vout Reporting is unknown.
|
|
voutAUTO(2) configure the Vout Reporting for automatic scaling.
|
|
vout208(3) configure the Vout Reporting for 208 Volts.
|
|
vout240(4) configure the Vout Reporting for 240 Volts."
|
|
::= { upsAdvConfig 24 }
|
|
|
|
upsAdvConfigNumExternalBatteries OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the number of external batteries connected to the UPS."
|
|
::= { upsAdvConfig 25 }
|
|
|
|
upsAdvConfigSimpleSignalShutdowns OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure Simple Signal shutdown commands from the Simple Signal
|
|
port to be issued to the UPS.
|
|
unknown(1) indicates the Simple Signal Shutdown setting is unknown.
|
|
disabled(2) configure to disable Simple Signal Shutdowns.
|
|
enabled(3) configure to enable Simple Signal Shutdowns."
|
|
::= { upsAdvConfig 26 }
|
|
|
|
upsAdvConfigMaxShutdownTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum amount of time for server shutdown to complete before a
|
|
UPS shutdown occurs."
|
|
::= { upsAdvConfig 27 }
|
|
|
|
upsAsiUpsControlServerRequestShutdown OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
serverShutdownOff (1),
|
|
serverShutdownReboot (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Start a server shutdown sequence:
|
|
serverShutdownOff: Shutdown server and turn off UPS
|
|
serverShutdownReboot: Shutdown server and turn reboot UPS."
|
|
::= { upsAdvConfig 28 }
|
|
|
|
upsAdvConfigMinReturnRuntime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum amount of run time in seconds required before the output will be
|
|
turned on, using power calculation captured at start of last shutdown."
|
|
::= { upsAdvConfig 29 }
|
|
|
|
upsAdvConfigBasicSignalLowBatteryDuration OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The duration of runtime in seconds during an on-battery condition at which
|
|
the UPS will signal the basic low battery shutdown condition."
|
|
::= { upsAdvConfig 30 }
|
|
|
|
upsAdvConfigBypassPhaseLockRequired OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sets the condition for when bypass is an acceptable mode of operation as a
|
|
requirement."
|
|
::= { upsAdvConfig 31 }
|
|
|
|
upsAdvConfigOutputFreqSlewRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
slewRateQuarterHzPerSec (2),
|
|
slewRateHalfHzPerSec (3),
|
|
slewRate1HzPerSec (4),
|
|
slewRate2HzPerSec (5),
|
|
slewRate4HzPerSec (6),
|
|
slewRate6HzPerSec (7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rate at which the UPS will change its output frequency
|
|
in response to utility frequency changes."
|
|
::= { upsAdvConfig 32 }
|
|
|
|
upsAdvConfigChargerLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
low (2),
|
|
high (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sets the rate at which the UPS charges its batteries."
|
|
::= { upsAdvConfig 33 }
|
|
|
|
upsAdvConfigBypassToleranceSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
wide (2),
|
|
medium (3),
|
|
narrow (4),
|
|
custom (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This setting allows selecting from standard bypass tolerance configurations to suit their situation."
|
|
::= { upsAdvConfig 34 }
|
|
|
|
upsAdvConfigMainsSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
singleInput (1),
|
|
dualInput (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the type of mains supply system.
|
|
singleInput (1) indicates a single supply system.
|
|
dualInput (2) indicates a dual supply system. "
|
|
::= { upsAdvConfig 35 }
|
|
|
|
upsAdvConfigACWiringSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
threeWire (1),
|
|
fourWire (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the AC wiring of the system.
|
|
threeWire (1) indicates 3-wire system configuration.
|
|
fourWire (2) indicates 4-wire system configuration. "
|
|
::= { upsAdvConfig 36 }
|
|
|
|
upsAdvConfigUpperOutputVoltTolerance OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Upper tolerance of the output RMS voltage before transferring to bypass.
|
|
Expressed as percent of nominal voltage."
|
|
::= { upsAdvConfig 37 }
|
|
|
|
upsAdvConfigLowerOutputVoltTolerance OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Lower tolerance of the output RMS voltage before transferring to bypass.
|
|
Expressed as percent of nominal voltage."
|
|
::= { upsAdvConfig 38 }
|
|
|
|
upsAdvConfigUpperBypassVoltTolerance OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Upper tolerance of the bypass voltage that allows transfer to bypass by user.
|
|
Expressed as percent of nominal voltage."
|
|
::= { upsAdvConfig 39 }
|
|
|
|
upsAdvConfigLowerBypassVoltTolerance OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Lower tolerance of the bypass voltage that allows transfer to bypass by user.
|
|
Expressed as percent of nominal voltage."
|
|
::= { upsAdvConfig 40 }
|
|
|
|
upsAdvConfigOutofSyncBypassTransferDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the time (in milliseconds), indicating the gap in output voltage
|
|
if an asynchronous transfer to bypass needs to occur."
|
|
::= { upsAdvConfig 41 }
|
|
|
|
|
|
|
|
|
|
upsAdvConfigWarningAlarmDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the time delay for reporting warning alarms
|
|
(in seconds)."
|
|
::= { upsAdvConfig 43 }
|
|
|
|
upsAdvConfigInformationalAlarmDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the time delay for reporting informational alarms
|
|
(in seconds)."
|
|
::= { upsAdvConfig 44 }
|
|
|
|
upsAdvConfigGreenMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/Disable UPS green mode feature."
|
|
::= { upsAdvConfig 45 }
|
|
|
|
upsAdvConfigLCDLocalLanguage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
english (1),
|
|
french (2),
|
|
italian (3),
|
|
german (4),
|
|
spanish (5),
|
|
portuguese (6),
|
|
japanese (7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the language setting of the UPS LCD display information."
|
|
::= { upsAdvConfig 46 }
|
|
|
|
upsAdvConfigLCDLockOut OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/Disable the control function of the UPS via the LCD Display."
|
|
::= { upsAdvConfig 47 }
|
|
|
|
upsAdvConfigChargerRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Change the maximum allowed UPS charge rate on select products where 100% represents
|
|
the manufacturer's recommended rate. A charge/discharge rate of C/10 for a 10 Ah
|
|
battery would be 1 where C is defined as the charge or discharge rate equal to the
|
|
capacity of a battery divided by 1 hour. To increase the charge rate by a factor of
|
|
2 to C/5, this oid would be set to 200%. This number would not change when external
|
|
packs are added or removed. Charging at too high a rate can result in boiling and/or
|
|
venting of electrolyte and/or high gas pressure."
|
|
::= { upsAdvConfig 48 }
|
|
|
|
upsAdvConfigBatterySelection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
vrla (1),
|
|
ventedcell (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the installed battery type on select products where VRLA is Valve Regulated
|
|
Lead Acid type battery and Vented Cell is a wet cell type (car) battery."
|
|
::= { upsAdvConfig 49 }
|
|
|
|
upsAdvConfigBatteryHealthAlarmWarningTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the number of days before the battery health is depleted that the battery
|
|
health alarm is activated. Setting this to -1, if supported by the UPS, will suppress
|
|
the battery health alarm."
|
|
::= { upsAdvConfig 50 }
|
|
|
|
upsAdvConfigBatteryHealthAlarmSleepTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the number of days that the UPS's battery health alarm should sleep before
|
|
being activated again after being acknowledged. Setting this to -1, if supported by the
|
|
UPS, displays no other alarms after the first alarm is acknowledged."
|
|
::= { upsAdvConfig 51 }
|
|
|
|
-- the upsSyncCtrlGroupConfig group
|
|
|
|
upsSCGMembershipGroupNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The SCG Membership Group number (MGN) is a 16-bit number allowing
|
|
up to 65534 separate groups that can be identified and distinguished
|
|
per IP subnet. Zero and 65535 are not used. The MGN is used in all
|
|
communication between members of the SCG and a Network Management Card
|
|
(NMC) will listen and only respond to commands sent to it using its
|
|
configured SCG ID."
|
|
::= { upsSyncCtrlGroupConfig 1 }
|
|
|
|
upsSCGActiveMembershipStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabledSCG (1),
|
|
disabledSCG (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Membership in the configured SCG can be enabled and
|
|
disabled. If an NMC is configured for an SCG, but
|
|
has its membership disabled, all synchronized control commands
|
|
received will be ignored."
|
|
::= { upsSyncCtrlGroupConfig 2 }
|
|
|
|
upsSCGPowerSynchronizationDelayTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Power Synchronization Delay Time (PSD) setting is the maximum
|
|
number of seconds an SCG Initiator will wait for all SCG members to
|
|
recover utility power before completing the reboot sequence of a
|
|
reboot or sleep command. If all SCG members are ready to proceed,
|
|
no additional delay is introduced."
|
|
::= { upsSyncCtrlGroupConfig 3 }
|
|
|
|
upsSCGReturnBatteryCapacityOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A reboot command uses the Initiator's Return battery Capacity (RBC) to control
|
|
when the SCG completes this operation. In a Normal Control Operation (NCC) the
|
|
UPS will only complete the reboot if RBC is reached. Due to normal battery
|
|
charge rate variations it may be desirable for the Followers to complete the
|
|
reboot if they are within some range of the Initiator's RBC when the Initiator
|
|
is prepared (charged to RBC) to complete the reboot. The Return Battery
|
|
Capacity Offset (RBCO) defines a percent battery capacity subtracted from an
|
|
RBC above which a Follower's battery must be charged for it to complete a
|
|
reboot. For example, if the Initiator's RBC is 50% and the Initiator's RBCO is
|
|
5% then a Follower's battery capacity is within range if it is greater or equal
|
|
to 45% (50% - 5%) at the time when the Initiator tries to complete the reboot
|
|
command. The default RBCO is 10%. "
|
|
::= { upsSyncCtrlGroupConfig 4 }
|
|
|
|
upsSCGMultiCastIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MultiCast IP address of the SCG Group."
|
|
::= { upsSyncCtrlGroupConfig 5 }
|
|
|
|
|
|
-- the upsSyncCtrlGroupStatus group
|
|
|
|
upsSCGNumOfGroupMembers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active, communicating members in the Sync Control Group (SCG).
|
|
This variable indicates the number of rows in the SCG Status Table."
|
|
::= { upsSyncCtrlGroupStatus 1 }
|
|
|
|
-- Sync Control Group Status Table
|
|
|
|
upsSCGStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsSCGStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of SCG status table entries. The number of entries
|
|
is given by the value of upsSCGNumOfGroupMembers."
|
|
::= { upsSyncCtrlGroupStatus 2 }
|
|
|
|
upsSCGStatusEntry OBJECT-TYPE
|
|
SYNTAX UpsSCGStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular SCG Member."
|
|
INDEX { upsSCGStatusTableIndex }
|
|
::= { upsSCGStatusTable 1 }
|
|
|
|
UpsSCGStatusEntry ::= SEQUENCE {
|
|
upsSCGStatusTableIndex INTEGER,
|
|
upsSCGMemberIP IpAddress,
|
|
upsSCGACInputStatus INTEGER,
|
|
upsSCGACOutputStatus INTEGER
|
|
}
|
|
|
|
upsSCGStatusTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of a status entry for an active, communicating SCG member."
|
|
::= { upsSCGStatusEntry 1 }
|
|
|
|
upsSCGMemberIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of an active, communicating SCG Member."
|
|
::= { upsSCGStatusEntry 2 }
|
|
|
|
upsSCGACInputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
acInGood(1),
|
|
acInBad(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID indicates the AC Input Status of the SCG Member.
|
|
acInGood(1) indicates the AC Input is within tolerance.
|
|
acInBad(2) indicates the AC Input is not within tolerance."
|
|
::= { upsSCGStatusEntry 3 }
|
|
|
|
upsSCGACOutputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
acOutOn(1),
|
|
acOutOff(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID indicates the AC Output Status of the SCG Member.
|
|
acOutOn(1) indicates the UPS output is providing power to the load.
|
|
acOutOff(2) indicates the UPS output is not providing power to the load. "
|
|
::= { upsSCGStatusEntry 4 }
|
|
|
|
-- the upsBasicState group
|
|
|
|
|
|
upsBasicStateOutputState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII string containing the 64 flags representing
|
|
the current state(s) of the UPS. If the Network Card
|
|
is unable to determine the state of the UPS, this
|
|
variable is set to 'UNKNOWN'.
|
|
|
|
The flags are numbered 1 to 64, read from left to
|
|
right. The flags are defined as follows:
|
|
|
|
Flag 1: Abnormal Condition Present
|
|
Flag 2: On Battery
|
|
Flag 3: Low Battery
|
|
Flag 4: On Line
|
|
|
|
Flag 5: Replace Battery
|
|
Flag 6: Serial Communication Established
|
|
Flag 7: AVR Boost Active
|
|
Flag 8: AVR Trim Active
|
|
|
|
Flag 9: Overload
|
|
Flag 10: Runtime Calibration
|
|
Flag 11: Batteries Discharged
|
|
Flag 12: Manual Bypass
|
|
|
|
Flag 13: Software Bypass
|
|
Flag 14: In Bypass due to Internal Fault
|
|
Flag 15: In Bypass due to Supply Failure
|
|
Flag 16: In Bypass due to Fan Failure
|
|
|
|
Flag 17: Sleeping on a Timer
|
|
Flag 18: Sleeping until Utility Power Returns
|
|
Flag 19: On
|
|
Flag 20: Rebooting
|
|
|
|
Flag 21: Battery Communication Lost
|
|
Flag 22: Graceful Shutdown Initiated
|
|
Flag 23: Smart Boost or Smart Trim Fault
|
|
Flag 24: Bad Output Voltage
|
|
|
|
Flag 25: Battery Charger Failure
|
|
Flag 26: High Battery Temperature
|
|
Flag 27: Warning Battery Temperature
|
|
Flag 28: Critical Battery Temperature
|
|
|
|
Flag 29: Self Test In Progress
|
|
Flag 30: Low Battery / On Battery
|
|
Flag 31: Graceful Shutdown Issued by Upstream Device
|
|
Flag 32: Graceful Shutdown Issued by Downstream Device
|
|
|
|
Flag 33: No Batteries Attached
|
|
Flag 34: Synchronized Command is in Progress
|
|
Flag 35: Synchronized Sleeping Command is in Progress
|
|
Flag 36: Synchronized Rebooting Command is in Progress
|
|
|
|
Flag 37: Inverter DC Imbalance
|
|
Flag 38: Transfer Relay Failure
|
|
Flag 39: Shutdown or Unable to Transfer
|
|
Flag 40: Low Battery Shutdown
|
|
|
|
Flag 41: Electronic Unit Fan Failure
|
|
Flag 42: Main Relay Failure
|
|
Flag 43: Bypass Relay Failure
|
|
Flag 44: Temporary Bypass
|
|
|
|
Flag 45: High Internal Temperature
|
|
Flag 46: Battery Temperature Sensor Fault
|
|
Flag 47: Input Out of Range for Bypass
|
|
Flag 48: DC Bus Overvoltage
|
|
|
|
Flag 49: PFC Failure
|
|
Flag 50: Critical Hardware Fault
|
|
Flag 51: Green Mode/ECO Mode
|
|
Flag 52: Hot Standby
|
|
|
|
Flag 53: Emergency Power Off (EPO) Activated
|
|
Flag 54: Load Alarm Violation
|
|
Flag 55: Bypass Phase Fault
|
|
Flag 56: UPS Internal Communication Failure
|
|
|
|
Flag 57: Efficiency Booster Mode
|
|
Flag 58: Off
|
|
Flag 59: Standby
|
|
Flag 60: <Not Used>
|
|
|
|
Flag 61: <Not Used>
|
|
Flag 62: <Not Used>
|
|
Flag 63: <Not Used>
|
|
Flag 64: <Not Used>"
|
|
::= { upsBasicState 1 }
|
|
|
|
|
|
|
|
-- the upsAdvState group
|
|
|
|
upsAdvStateAbnormalConditions OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII string containing the 32 flags representing
|
|
the current active UPS faults. If the Network Card
|
|
is unable to determine the values of the flags, this
|
|
variable is set to 'UNKNOWN'. If this variable is not
|
|
supported by the connected UPS, this variable is set to
|
|
'NOT SUPPORTED'.
|
|
|
|
The flags are numbered from 1 to 32, and read from left to
|
|
right. The flags are defined as follows:
|
|
|
|
Flag 1: Power Module Failure
|
|
Flag 2: Main Intelligence Module Failure
|
|
Flag 3: Redundant Intelligence Module Failure
|
|
Flag 4: Battery Failure
|
|
|
|
Flag 5: Load(kVA) Alarm Threshold Violation
|
|
Flag 6: Redundancy Lost
|
|
Flag 7: Redundancy Below Alarm Threshold
|
|
Flag 8: Bypass not in Range; Either Frequency or Voltage
|
|
|
|
Flag 9: Bypass Contactor Stuck in Bypass Condition
|
|
Flag 10: Bypass Contactor Stuck in On-Line Condition
|
|
Flag 11: In Bypass due to an Internal Fault
|
|
Flag 12: In Bypass due to an Overload
|
|
|
|
Flag 13: In Maintenance Bypass
|
|
Flag 14: Input Circuit Braker Tripped Open
|
|
Flag 15: System Level Fan Failure
|
|
Flag 16: Redundant Intelligent Module in Control
|
|
|
|
Flag 17: IIC Inter-Module Communication Failure
|
|
Flag 18: No Working Power Modules
|
|
Flag 19: Load Shutdown From Bypass; Input Frequency
|
|
Flag 20: Runtime Below Alarm Threshold
|
|
|
|
Flag 21: Extended Run Frame Fault
|
|
Flag 22: Output Voltage out of Range
|
|
Flag 23: UPS Not Synchronized
|
|
Flag 24: No Batteries Installed
|
|
|
|
Flag 25: Battery Voltage High
|
|
Flag 26: UPS Specific Fault Detected
|
|
Flag 27: Site Wiring Fault
|
|
Flag 28: Backfeed Protection Relay Opened
|
|
|
|
Flag 29: <Not Used>
|
|
Flag 30: <Not Used>
|
|
Flag 31: <Not Used>
|
|
Flag 32: <Not Used>"
|
|
::= { upsAdvState 1 }
|
|
|
|
upsAdvStateSymmetra3PhaseSpecificFaults OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII string containing the 64 flags representing
|
|
the current active UPS specific faults for the Symmetra
|
|
3-Phase UPS models. If the Network Card is unable to
|
|
determine the values of the flags, this variable is set
|
|
to 'UNKNOWN'. If the connected UPS does not use this
|
|
variable, it is set to 'NOT SUPPORTED'.
|
|
|
|
The flags are numbered from 1 to 64, and read from left
|
|
to right. The bits are defined as follows:
|
|
|
|
Flag 1: External Switch Gear Failure
|
|
Flag 2: External Transformer Over Temperature
|
|
Flag 3: External DC Circuit Breaker Tripped
|
|
Flag 4: System Power Supply Failure
|
|
|
|
Flag 5: Battery Monitor Card Failure
|
|
Flag 6: Battery Monitor Card Removed
|
|
Flag 7: XR Communication Card Failure
|
|
Flag 8: XR Communication Card Removed
|
|
|
|
Flag 9: External Switch Gear Monitoring Card Failure
|
|
Flag 10: External Switch Gear Monitoring Card Removed
|
|
Flag 11: Internal DC Circuit Breaker Tripped
|
|
Flag 12: Static Bypass Switch Failure
|
|
|
|
Flag 13: System EEPROM Removed
|
|
Flag 14: System EEPROM Failure
|
|
Flag 15: UPS in Forced Bypass
|
|
Flag 16: Static Bypass Switch Module Removed
|
|
|
|
Flag 17: System Start-Up Configuration Fault
|
|
Flag 18: Battery Charger Shutdown Externally
|
|
Flag 19: <Not Used>
|
|
Flag 20: <Not Used>
|
|
|
|
Flag 21: <Not Used>
|
|
Flag 22: <Not Used>
|
|
Flag 23: <Not Used>
|
|
Flag 24: <Not Used>
|
|
|
|
Flag 25: <Not Used>
|
|
Flag 26: <Not Used>
|
|
Flag 27: <Not Used>
|
|
Flag 28: <Not Used>
|
|
|
|
Flag 29: <Not Used>
|
|
Flag 30: <Not Used>
|
|
Flag 31: <Not Used>
|
|
Flag 32: <Not Used>
|
|
|
|
Flag 33: <Not Used>
|
|
Flag 34: <Not Used>
|
|
Flag 35: <Not Used>
|
|
Flag 36: <Not Used>
|
|
|
|
Flag 37: <Not Used>
|
|
Flag 38: <Not Used>
|
|
Flag 39: <Not Used>
|
|
Flag 40: <Not Used>
|
|
|
|
Flag 41: <Not Used>
|
|
Flag 42: <Not Used>
|
|
Flag 43: <Not Used>
|
|
Flag 44: <Not Used>
|
|
|
|
Flag 45: <Not Used>
|
|
Flag 46: <Not Used>
|
|
Flag 47: <Not Used>
|
|
Flag 48: <Not Used>
|
|
|
|
Flag 49: <Not Used>
|
|
Flag 50: <Not Used>
|
|
Flag 51: <Not Used>
|
|
Flag 52: <Not Used>
|
|
|
|
Flag 53: <Not Used>
|
|
Flag 54: <Not Used>
|
|
Flag 55: <Not Used>
|
|
Flag 56: <Not Used>
|
|
|
|
Flag 57: <Not Used>
|
|
Flag 58: <Not Used>
|
|
Flag 59: <Not Used>
|
|
Flag 60: <Not Used>
|
|
|
|
Flag 61: <Not Used>
|
|
Flag 62: <Not Used>
|
|
Flag 63: <Not Used>
|
|
Flag 64: <Not Used>"
|
|
::= { upsAdvState 2 }
|
|
|
|
upsAdvStateDP300ESpecificFaults OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII string containing the 64 flags representing
|
|
the current active UPS specific faults for the Silcon
|
|
DP300E UPS models. If the Network Card is unable to
|
|
determine the values of the flags, this variable is set
|
|
to 'UNKNOWN'. If the connected UPS does not use this
|
|
variable, it is set to 'NOT SUPPORTED'.
|
|
|
|
The flags are numbered from 1 to 64, and read from left
|
|
to right. The bits are defined as follows:
|
|
|
|
Flag 1: Peak Current Limiter Active
|
|
Flag 2: Bypass Power Supply Fault
|
|
Flag 3: Delta Current Limiter Active
|
|
Flag 4: Fan Fault
|
|
|
|
Flag 5: High DC warning
|
|
Flag 6: Inverter Voltage Error
|
|
Flag 7: Parallel Synchronization Error
|
|
Flag 8: Second Power Supply Fault
|
|
|
|
Flag 9: Internal Power Supply Fault
|
|
Flag 10: <Not Used>
|
|
Flag 11: <Not Used>
|
|
Flag 12: <Not Used>
|
|
|
|
Flag 13: <Not Used>
|
|
Flag 14: Bypass Static Switch High Temperature
|
|
Flag 15: High Battery Temperature
|
|
Flag 16: Battery Weak
|
|
|
|
Flag 17: <Not Used>
|
|
Flag 18: System Locked in Operation Mode
|
|
Flag 19: RAM1 Memory Write Error
|
|
Flag 20: Memory Write Error
|
|
|
|
Flag 21: Communication to VQ Bypass Lost
|
|
Flag 22: Communication to VQ Output Lost
|
|
Flag 23: Communication to DMU Lost
|
|
Flag 24: Communication to Controller Lost
|
|
|
|
Flag 25: Communication to Parallel IF Lost
|
|
Flag 26: External Shutdown Accepted
|
|
Flag 27: DC Capacitor Charge Error
|
|
Flag 28: Communication to VQ Mains Lost
|
|
|
|
Flag 29: Bypass Synchronization Error
|
|
Flag 30: Charge Error
|
|
Flag 31: SII Aux Input Activiated
|
|
Flag 32: <Not Used>
|
|
|
|
Flag 33: Blown Inverter Fuse
|
|
Flag 34: Blown Rectifier Fuse
|
|
Flag 35: Auxilliary 1 Fault
|
|
Flag 36: <Not Used>
|
|
|
|
Flag 37: <Not Used>
|
|
Flag 38: <Not Used>
|
|
Flag 39: <Not Used>
|
|
Flag 40: <Not Used>
|
|
|
|
Flag 41: <Not Used>
|
|
Flag 42: <Not Used>
|
|
Flag 43: <Not Used>
|
|
Flag 44: <Not Used>
|
|
|
|
Flag 45: <Not Used>
|
|
Flag 46: High Temperature Charger Magnetic
|
|
Flag 47: <Not Used>
|
|
Flag 48: Battery Monitor Warning
|
|
|
|
Flag 49: Battery Monitor Alarm
|
|
Flag 50: <Not Used>
|
|
Flag 51: <Not Used>
|
|
Flag 52: <Not Used>
|
|
|
|
Flag 53: TSM 1/2/3 Temperature Shutdown
|
|
Flag 54: Charger 0/30 Temperature Warning
|
|
Flag 55: Charger 0/30 Temperature Shutdown
|
|
Flag 56: High Output Voltage
|
|
|
|
Flag 57: SSW Temperature Over 90
|
|
Flag 58: <Not Used>
|
|
Flag 59: Low Current Failure In AC Capacitors
|
|
Flag 60: <Not Used>
|
|
|
|
Flag 61: Advanced Battery Management Not Installed
|
|
Flag 62: <Not Used>
|
|
Flag 63: <Not Used>
|
|
Flag 64: <Not Used>"
|
|
::= { upsAdvState 3 }
|
|
|
|
upsAdvStateSymmetraSpecificFaults OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII string containing the 64 flags representing
|
|
the current active UPS specific faults for the Symmetra
|
|
UPS models. If the Network Card is unable to determine
|
|
the values of the flags, this variable is set to 'UNKNOWN'.
|
|
If the connected UPS does not use this variable, it is
|
|
set to 'NOT SUPPORTED'.
|
|
|
|
The flags are numbered from 1 to 64, and read from left
|
|
to right. The bits are defined as follows:
|
|
|
|
Flag 1: System Fault
|
|
Flag 2: Bypass Relay Fault
|
|
Flag 3: Power Module Turn Off Failure
|
|
Flag 4: Frame Identification Fault
|
|
|
|
Flag 5: <Not Used>
|
|
Flag 6: <Not Used>
|
|
Flag 7: <Not Used>
|
|
Flag 8: <Not Used>
|
|
|
|
Flag 9: <Not Used>
|
|
Flag 10: <Not Used>
|
|
Flag 11: <Not Used>
|
|
Flag 12: <Not Used>
|
|
|
|
Flag 13: <Not Used>
|
|
Flag 14: <Not Used>
|
|
Flag 15: <Not Used>
|
|
Flag 16: <Not Used>
|
|
|
|
Flag 17: <Not Used>
|
|
Flag 18: <Not Used>
|
|
Flag 19: <Not Used>
|
|
Flag 20: <Not Used>
|
|
|
|
Flag 21: <Not Used>
|
|
Flag 22: <Not Used>
|
|
Flag 23: <Not Used>
|
|
Flag 24: <Not Used>
|
|
|
|
Flag 25: <Not Used>
|
|
Flag 26: <Not Used>
|
|
Flag 27: <Not Used>
|
|
Flag 28: <Not Used>
|
|
|
|
Flag 29: <Not Used>
|
|
Flag 30: <Not Used>
|
|
Flag 31: <Not Used>
|
|
Flag 32: <Not Used>
|
|
|
|
Flag 33: <Not Used>
|
|
Flag 34: <Not Used>
|
|
Flag 35: <Not Used>
|
|
Flag 36: <Not Used>
|
|
|
|
Flag 37: <Not Used>
|
|
Flag 38: <Not Used>
|
|
Flag 39: <Not Used>
|
|
Flag 40: <Not Used>
|
|
|
|
Flag 41: <Not Used>
|
|
Flag 42: <Not Used>
|
|
Flag 43: <Not Used>
|
|
Flag 44: <Not Used>
|
|
|
|
Flag 45: <Not Used>
|
|
Flag 46: <Not Used>
|
|
Flag 47: <Not Used>
|
|
Flag 48: <Not Used>
|
|
|
|
Flag 49: <Not Used>
|
|
Flag 50: <Not Used>
|
|
Flag 51: <Not Used>
|
|
Flag 52: <Not Used>
|
|
|
|
Flag 53: <Not Used>
|
|
Flag 54: <Not Used>
|
|
Flag 55: <Not Used>
|
|
Flag 56: <Not Used>
|
|
|
|
Flag 57: <Not Used>
|
|
Flag 58: <Not Used>
|
|
Flag 59: <Not Used>
|
|
Flag 60: <Not Used>
|
|
|
|
Flag 61: <Not Used>
|
|
Flag 62: <Not Used>
|
|
Flag 63: <Not Used>
|
|
Flag 64: <Not Used>"
|
|
::= { upsAdvState 4 }
|
|
|
|
upsAdvStateSmartUPSSpecificFaults OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII string containing the 64 flags representing
|
|
the current active UPS specific faults for the Smart-UPS
|
|
UPS models. If the Network Card is unable to determine
|
|
the values of the flags, this variable is set to
|
|
'UNKNOWN'. If the connected UPS does not use this
|
|
variable, it is set to 'NOT SUPPORTED'.
|
|
|
|
The flags are numbered from 1 to 64, and read from left
|
|
to right. The bits are defined as follows:
|
|
|
|
Flag 1: EPO Switch Activated
|
|
Flag 2: Static Bypass Switch Fault
|
|
Flag 3: System Configuration Fault
|
|
Flag 4: Power Supply Unit Fault
|
|
|
|
Flag 5: Weak Battery
|
|
Flag 6: High Battery Temperature
|
|
Flag 7: Internal Mechanical Bypass
|
|
Flag 8: Loss Of Parallel Redundancy
|
|
|
|
Flag 9: Parallel Bus Communication Fault on Cable 1
|
|
Flag 10: Parallel Bus Communication Fault on Cable 2
|
|
Flag 11: Auxiliary Bus Communication Fault
|
|
Flag 12: Parallel Bus Termination Fault on Cable 1
|
|
|
|
Flag 13: Parallel Bus Termination Fault on Cable 2
|
|
Flag 14: Auxiliary Bus Termination Fault
|
|
Flag 15: No Master Present In The Parallel System
|
|
Flag 16: Overload on a Parallel Unit
|
|
|
|
Flag 17: Parallel Configuration Fault
|
|
Flag 18: <Not Used>
|
|
Flag 19: <Not Used>
|
|
Flag 20: <Not Used>
|
|
|
|
Flag 21: <Not Used>
|
|
Flag 22: <Not Used>
|
|
Flag 23: <Not Used>
|
|
Flag 24: <Not Used>
|
|
|
|
Flag 25: <Not Used>
|
|
Flag 26: <Not Used>
|
|
Flag 27: <Not Used>
|
|
Flag 28: <Not Used>
|
|
|
|
Flag 29: <Not Used>
|
|
Flag 30: <Not Used>
|
|
Flag 31: <Not Used>
|
|
Flag 32: <Not Used>
|
|
|
|
Flag 33: <Not Used>
|
|
Flag 34: <Not Used>
|
|
Flag 35: <Not Used>
|
|
Flag 36: <Not Used>
|
|
|
|
Flag 37: <Not Used>
|
|
Flag 38: <Not Used>
|
|
Flag 39: <Not Used>
|
|
Flag 40: <Not Used>
|
|
|
|
Flag 41: <Not Used>
|
|
Flag 42: <Not Used>
|
|
Flag 43: <Not Used>
|
|
Flag 44: <Not Used>
|
|
|
|
Flag 45: <Not Used>
|
|
Flag 46: <Not Used>
|
|
Flag 47: <Not Used>
|
|
Flag 48: <Not Used>
|
|
|
|
Flag 49: <Not Used>
|
|
Flag 50: <Not Used>
|
|
Flag 51: <Not Used>
|
|
Flag 52: <Not Used>
|
|
|
|
Flag 53: <Not Used>
|
|
Flag 54: <Not Used>
|
|
Flag 55: <Not Used>
|
|
Flag 56: <Not Used>
|
|
|
|
Flag 57: <Not Used>
|
|
Flag 58: <Not Used>
|
|
Flag 59: <Not Used>
|
|
Flag 60: <Not Used>
|
|
|
|
Flag 61: <Not Used>
|
|
Flag 62: <Not Used>
|
|
Flag 63: <Not Used>
|
|
Flag 64: <Not Used>"
|
|
::= { upsAdvState 5 }
|
|
|
|
|
|
upsAdvStateSystemMessages OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII string containing the 3 digit Decimal code
|
|
representing the current active message from the
|
|
System Message Register. Each code should remain active
|
|
for a minimum of 15 seconds. However, in the worst case
|
|
scenario, a code could be cleared after only 5 seconds.
|
|
It is recommended that this object be polled at least
|
|
once every 4 seconds in order to get the most accurate
|
|
representation of the current UPS System Message. If the
|
|
Network Card is unable to determine the value of the
|
|
System Message Register, this variable is set to
|
|
'UNKNOWN'."
|
|
::= { upsAdvState 6 }
|
|
|
|
|
|
upsAdvStateTotaltimeonbattery OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total time the UPS has been in battery operation."
|
|
::= { upsAdvState 7 }
|
|
|
|
upsAdvStateTotaltimeonbypass OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total time the UPS has been in bypass operation."
|
|
::= { upsAdvState 8 }
|
|
|
|
upsAdvStateTotaltimeonNormal OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total time the UPS has been in normal operation."
|
|
::= { upsAdvState 9 }
|
|
|
|
upsAdvStateNumberoftimesonbattery OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of times the UPS was on battery.
|
|
Since the last reset of statistical data."
|
|
::= { upsAdvState 10 }
|
|
|
|
upsAdvStateNumberoftimesbypass OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of times the UPS was in bypass.
|
|
Since the last reset of statistical data."
|
|
::= { upsAdvState 11 }
|
|
|
|
upsAdvStateNumberoftimesNormal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of times the UPS was in normal operation.
|
|
Since the last reset of statistical data."
|
|
::= { upsAdvState 12 }
|
|
|
|
upsAdvStateEcomode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsOnEcoMode(1),
|
|
upsNotOnEcoMode(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Eco mode status.
|
|
1: UPS is on Eco-mode
|
|
2: UPS is not on Eco-mode."
|
|
::= { upsAdvState 13 }
|
|
|
|
-- the upsBasicControl group
|
|
|
|
upsBasicControlConserveBattery OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTurnOffUps(1),
|
|
turnOffUpsToConserveBattery(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to turnUpsOffToConserveBattery(2)
|
|
causes a UPS on battery to be put into 'sleep' mode. The
|
|
UPS will turn back on when utility power is restored.
|
|
Attempting to turn off a UPS that is not on battery will
|
|
result in a badValue error.
|
|
|
|
Setting this value to noTurnOffUps(1) has no
|
|
effect.
|
|
|
|
The value noTurnOffUps(1) will always be returned
|
|
when the variable is read."
|
|
::= { upsBasicControl 1 }
|
|
|
|
|
|
|
|
-- the upsAdvControl group
|
|
|
|
upsAdvControlUpsOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTurnUpsOff(1),
|
|
turnUpsOff(2),
|
|
turnUpsOffGracefully(3),
|
|
turnUpsSyncGroupOff(4),
|
|
turnUpsSyncGroupOffAfterDelay(5),
|
|
turnUpsSyncGroupOffGracefully(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to turnUpsOff(2) causes
|
|
the UPS to shut off. When in this state, the UPS
|
|
will not provide output power regardless of the input
|
|
line state.
|
|
|
|
Setting this variable to turnUpsOffGracefully(3) causes
|
|
the UPS to shut off after a delay period. This allows the
|
|
host to shut down in a graceful manner. When in this state,
|
|
the UPS will not provide output power regardless of the
|
|
input line state.
|
|
|
|
If this UPS is an active member of a Synchronized
|
|
Control Group (SCG) the turnUpsSyncGroupOff(4) command
|
|
will perform a Synchronized Turn Off of all active Group
|
|
members regardless of their current AC output status.
|
|
|
|
If this UPS is an active member of a Synchronized
|
|
Control Group (SCG) the turnUpsSyncGroupOffAfterDelay(5)
|
|
command will perform a Synchronized Turn Off After Delay
|
|
of all active Group members regardless of their current
|
|
AC output status. This unit's Shutdown Delay will be used
|
|
to execute the Turn Off After Delay command.
|
|
|
|
If this UPS is an active member of an SCG, the
|
|
turnUpsSyncGroupOffGracefully(6) command will perform a
|
|
Synchronized Turn Off Gracefully of all active Group
|
|
members regardless of their current AC output status.
|
|
This unit's Maximum Shutdown Time and Shutdown Delay will
|
|
be used to execute the Turn Off Gracefully command.
|
|
|
|
Setting this value to noTurnUpsOff(1) has no
|
|
effect.
|
|
|
|
The value noTurnUpsOff(1) will always be returned
|
|
when the variable is read."
|
|
::= { upsAdvControl 1 }
|
|
|
|
upsAdvControlRebootShutdownUps OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noRebootShutdownUps(1),
|
|
rebootShutdownUps(2),
|
|
rebootShutdownUpsGracefully(3),
|
|
rebootShutdownSyncGroupUps(4),
|
|
rebootShutdownSyncGroupUpsGracefully(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to rebootShutdownUps(2) causes the UPS
|
|
to shut off and turn back on (as long as good AC input power
|
|
is available, otherwise the UPS will remain off until good AC
|
|
input power is available).
|
|
|
|
Setting this variable to rebootShutdownUpsGracefully(3) causes
|
|
the UPS to shut off after a delay period and then turn back
|
|
on. This allows the host to shut down in a graceful manner.
|
|
|
|
If this UPS is an active member of a Synchronized Control
|
|
Group (SCG) the rebootShutdownSyncGroupUps(4) command will
|
|
perform a Synchronized Reboot of all active Group members
|
|
regardless of their current AC output status. If applicable,
|
|
this unit's Power Synchronization Delay, Shutdown Delay,
|
|
Return Delay, Return Battery Capacity, and Return Battery
|
|
Capacity Offset will be used to execute the Reboot command.
|
|
|
|
If this UPS is an active member of a SCG the
|
|
rebootShutdownSyncGroupUpsGracefully(5) command will perform
|
|
a Synchronized Reboot of all active Group members regardless
|
|
of their current AC output status. If applicable, this unit's
|
|
Power Synchronization Delay, Maximum Shutdown Time, Shutdown
|
|
Delay, Return Delay, Return Battery Capacity, and Return
|
|
Battery Capacity Offset will be used to execute the Reboot
|
|
command.
|
|
|
|
Setting this value to noRebootShutdownUps(1) has no effect.
|
|
|
|
The value noRebootShutdownUps(1) will always be returned when
|
|
the variable is read."
|
|
::= { upsAdvControl 2 }
|
|
|
|
upsAdvControlUpsSleep OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noPutUpsToSleep(1),
|
|
putUpsToSleep(2),
|
|
putUpsToSleepGracefully(3),
|
|
putUpsSyncGroupToSleep(4),
|
|
putUpsSyncGroupToSleepGracefully(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to putUpsToSleep(2) causes
|
|
the UPS to go to sleep for the time specified by
|
|
upsAdvConfigUpsSleepTime.
|
|
|
|
Setting this variable to putUpsToSleepGracefully(3)
|
|
causes the UPS to go to sleep for the time specified
|
|
by upsAdvConfigUpsSleepTime after a delay period.
|
|
This allows the host to shut down in a graceful manner.
|
|
|
|
If this UPS is an active member of a Synchronized Control
|
|
Group (SCG), the putUpsSyncGroupToSleep(4) command will perform
|
|
a Synchronized Sleep of all active Group members regardless
|
|
of their current AC output status. This unit's Power
|
|
Synchronization Delay, Shutdown Delay, Sleep Time,
|
|
and Return Delay will be used to execute the sleep command.
|
|
|
|
If this UPS is an active member of a SCG the
|
|
putUpsSyncGroupToSleepGracefully(5) command will perform a
|
|
Synchronized Sleep Gracefully of all active Group members
|
|
regardless of their current AC output status. This unit's
|
|
Power Synchronization Delay, Maximum Shutdown Time, Shutdown
|
|
Delay, Sleep Time, and Return Delay to execute the sleep
|
|
command.
|
|
|
|
When in sleep mode, the UPS will not provide output
|
|
power regardless of the input line state. Once the
|
|
specified time has elapsed, output power will be
|
|
restored.
|
|
|
|
Setting this value to noPutUpsToSleep(1) has no
|
|
effect.
|
|
|
|
The value noPutUpsToSleep(1) will always be returned
|
|
when the variable is read."
|
|
::= { upsAdvControl 3 }
|
|
|
|
|
|
upsAdvControlSimulatePowerFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noSimulatePowerFailure(1),
|
|
simulatePowerFailure(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to simulatePowerFailure(2) causes
|
|
the UPS switch to battery power.
|
|
|
|
Setting this value to noSimulatePowerFailure(1) has no
|
|
effect.
|
|
|
|
The value noSimulatePowerFailure(1) will always be returned
|
|
when the variable is read."
|
|
::= { upsAdvControl 4 }
|
|
|
|
|
|
upsAdvControlFlashAndBeep OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noFlashAndBeep(1),
|
|
flashAndBeep(2),
|
|
flashAndBeepSyncGroup(3),
|
|
flashAndBeepCont(4),
|
|
flashAndBeepCancel(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to flashAndBeep(2) causes the
|
|
UPS to beep and simultaneously turn on the UPS front
|
|
panel lights (Smart-UPS only).
|
|
|
|
If this UPS is an active member of a Synchronized Control
|
|
Group (SCG), the flashAndBeepSyncGroup(3) command will
|
|
Flash and Beep all active Group members regardless of
|
|
current AC output status.
|
|
|
|
Setting this value to noFlashAndBeep(1) has no
|
|
effect.
|
|
|
|
Setting this value to flashAndBeepCont (4) commandcauses
|
|
the UPS to beep and light the front panel lights until
|
|
the flashAndBeepCancel (5) command is received.
|
|
|
|
The value noFlashAndBeep(1) will always be returned
|
|
when the variable is read."
|
|
::= { upsAdvControl 5 }
|
|
|
|
|
|
upsAdvControlTurnOnUPS OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTurnOnUPS(1),
|
|
turnOnUPS(2),
|
|
turnOnUPSSyncGroup(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to turnOnUPS(2) causes the
|
|
UPS to be turned on immediately.
|
|
|
|
If this UPS is an active member of a Synchronized Control
|
|
Group (SCG), the turnOnUPSSyncGroup(3) command will perform
|
|
a Synchronized Turn On of all active Group members
|
|
regardless of their current AC output status.
|
|
|
|
Setting this value to noTurnOnUPS(1) has no
|
|
effect.
|
|
|
|
The value noTurnOnUPS(1) will always be returned
|
|
when the variable is read."
|
|
::= { upsAdvControl 6 }
|
|
|
|
upsAdvControlBypassSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noBypassSwitch (1),
|
|
switchToBypass (2),
|
|
switchOutOfBypass(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This switch puts the UPS in or out of bypass mode."
|
|
::= { upsAdvControl 7 }
|
|
|
|
upsAdvControlRebootUpsWithOrWithoutAC OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noRebootUpsWithOrWithoutAC (1),
|
|
rebootUpsImmediatelyWithOrWithoutAC (2),
|
|
rebootUpsDelayedWithOrWithoutAC (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to rebootUpsImmediatelyWithOrWithoutAC (2)
|
|
causes the UPS to turn off immediately, wait for a minimum time
|
|
(typically 8 seconds), and then turn back on regardless of the
|
|
AC input power on the UPS. Any supported switched outlet
|
|
groups will be turned off immediately but will turn on based
|
|
on their individual settings (to allow on sequencing).
|
|
|
|
Setting this variable to rebootUpsDelayedWithOrWithoutAC (3)
|
|
causes the UPS to turn off after a delay period, wait for a
|
|
minimum time (typically 8 seconds), and then turn back on
|
|
regardless of the AC input power on the UPS. Any supported
|
|
switched outlet groups will be turned off and on based on their
|
|
individual settings (to allow off and/or on sequencing).
|
|
|
|
Setting this value to noRebootUpsWithOrWithoutAC (1) has no
|
|
effect.
|
|
|
|
The value noRebootUpsWithOrWithoutAC (1) will always be
|
|
returned when the variable is read."
|
|
::= { upsAdvControl 8 }
|
|
|
|
upsAdvControlFirmwareUpdate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noFirmwareUpdate (1),
|
|
firmwareUpdate (2),
|
|
updateInProcess (3),
|
|
updateSuccessful (4),
|
|
updateFailed (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to firmwareUpdate(2) causes the
|
|
UPS to begin a firmware update if possible.
|
|
|
|
Setting this value to noFirmwareUpdate(1) will clear the
|
|
previous results, if any, or otherwise has no effect.
|
|
|
|
Reading this variable will return noFirmwareUpdate(1) when
|
|
the UPS firmware has not been updated (or previous results
|
|
have been cleared), updateInProcess(3) when the UPS firmware
|
|
is being updated, updateSuccessful(4) when the UPS firmware
|
|
has been successfully updated, or updateFailed(5) if the UPS
|
|
firmware update failed."
|
|
::= { upsAdvControl 9 }
|
|
|
|
|
|
-- the upsTest group
|
|
|
|
-- the upsBasicTest group
|
|
|
|
-- the upsAdvTest group
|
|
|
|
upsAdvTestDiagnosticSchedule OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
biweekly(2),
|
|
weekly(3),
|
|
atTurnOn(4),
|
|
never(5),
|
|
fourWeeks(6),
|
|
twelveWeeks(7),
|
|
biweeklySinceLastTest(8),
|
|
weeklySinceLastTest(9),
|
|
eightWeeks(10),
|
|
twentysixWeeks(11),
|
|
fiftytwoWeeks(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS system's automatic battery test schedule."
|
|
::= { upsAdvTest 1 }
|
|
|
|
|
|
upsAdvTestDiagnostics OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTestDiagnostics(1),
|
|
testDiagnostics(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to testDiagnostics(2) causes
|
|
the UPS to perform a diagnostic self test.
|
|
|
|
Setting this value to noTestDiagnostics(1) has no
|
|
effect.
|
|
|
|
The value noTestDiagnostics(1) will always be returned
|
|
when the variable is read."
|
|
::= { upsAdvTest 2 }
|
|
|
|
upsAdvTestDiagnosticsResults OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
failed(2),
|
|
invalidTest(3),
|
|
testInProgress(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The results of the last UPS diagnostics test performed."
|
|
::= { upsAdvTest 3 }
|
|
|
|
upsAdvTestLastDiagnosticsDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date the last UPS diagnostics test was performed in
|
|
mm/dd/yy format."
|
|
::= { upsAdvTest 4 }
|
|
|
|
upsAdvTestRuntimeCalibration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noPerformCalibration(1),
|
|
performCalibration(2),
|
|
cancelCurrentCalibration(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to performCalibration(2) causes
|
|
the UPS to discharge to calibrate the UPS.
|
|
The test will only start if the battery capacity is 100%.
|
|
The test runs until capacity is less than 25%.
|
|
|
|
Setting this variable to cancelCurrentCalibration(3)
|
|
after setting performCalibration(2) will cancel the
|
|
current discharge.
|
|
|
|
Setting this variable to noPerformCalibration(1)
|
|
will have no effect.
|
|
|
|
The value noPerformCalibration(1) will always be returned
|
|
when the variable is read.
|
|
|
|
The result of the calibration will be saved in
|
|
upsAdvTestCalibrationResult."
|
|
::= { upsAdvTest 5 }
|
|
|
|
upsAdvTestCalibrationResults OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
invalidCalibration(2),
|
|
calibrationInProgress(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The results of the last runtime calibration.
|
|
|
|
Value ok(1) means a successful runtime calibration.
|
|
|
|
Value invalidCalibration(2) indicates last calibration did
|
|
not take place since the battery capacity was below
|
|
100%.
|
|
|
|
Value calibrationInProgress(3) means a calibration
|
|
is occurring now. "
|
|
::= { upsAdvTest 6 }
|
|
|
|
upsAdvTestCalibrationDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date the last UPS runtime calibration was
|
|
performed in mm/dd/yy format."
|
|
::= { upsAdvTest 7 }
|
|
|
|
upsAdvTestDiagnosticTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time of the day to perform automatic battery test.
|
|
Expressed in 24 hour notation - hh:mm."
|
|
::= { upsAdvTest 8 }
|
|
|
|
upsAdvTestDiagnosticDay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
monday (1),
|
|
tuesday (2),
|
|
wednesday (3),
|
|
thursday (4),
|
|
friday (5),
|
|
saturday (6),
|
|
sunday (7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The day of the week to perform automatic battery test."
|
|
::= { upsAdvTest 9 }
|
|
|
|
-- the upsComm group
|
|
|
|
upsCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
noComm(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of agent's communication with UPS. "
|
|
::= { upsComm 1 }
|
|
|
|
|
|
-- the measureUps group
|
|
-- the Environ group
|
|
|
|
mUpsEnvironAmbientTemperature OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ambient temperature in Celsius for Probe 1."
|
|
::= { mUpsEnviron 1 }
|
|
|
|
mUpsEnvironRelativeHumidity OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative humidity as a percentage for Probe 1."
|
|
::= { mUpsEnviron 2 }
|
|
|
|
|
|
mUpsEnvironAmbientTemperature2 OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ambient temperature in Celsius for Probe 2."
|
|
::= { mUpsEnviron 3 }
|
|
|
|
mUpsEnvironRelativeHumidity2 OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative humidity as a percentage for Probe 2."
|
|
::= { mUpsEnviron 4 }
|
|
|
|
-- the mUpsContact group
|
|
|
|
mUpsContactNumContacts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of contacts supported by the Measure-UPS."
|
|
::= { mUpsContact 1 }
|
|
|
|
mUpsContactTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MUpsContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of contacts supported by the Measure-UPS."
|
|
::= { mUpsContact 2 }
|
|
|
|
mUpsContactEntry OBJECT-TYPE
|
|
SYNTAX MUpsContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A contact entry containing information for a given contact."
|
|
INDEX { contactNumber }
|
|
::= { mUpsContactTable 1 }
|
|
|
|
MUpsContactEntry ::=
|
|
SEQUENCE {
|
|
contactNumber
|
|
INTEGER,
|
|
normalState
|
|
INTEGER,
|
|
description
|
|
DisplayString,
|
|
monitoringStatus
|
|
INTEGER,
|
|
currentStatus
|
|
INTEGER
|
|
}
|
|
|
|
contactNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An index identifying the contact on the Measure-UPS."
|
|
::= { mUpsContactEntry 1 }
|
|
|
|
normalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
open(2),
|
|
closed(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal operating position of the contact. If the normal
|
|
operating position cannot be set then it is controlled via the
|
|
dip switch on the Measure-UPS and is therefore read-only."
|
|
::= { mUpsContactEntry 2 }
|
|
|
|
description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the purpose/use of the contact."
|
|
::= { mUpsContactEntry 3 }
|
|
|
|
monitoringStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
enabled(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A flag indicating whether this contact is
|
|
monitored, or not."
|
|
::= { mUpsContactEntry 4 }
|
|
|
|
currentStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
noFault(2),
|
|
fault(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value indicates the current state of the contact.
|
|
If the contact is not in its normal state. This value
|
|
is set to fault(2)."
|
|
::= { mUpsContactEntry 5 }
|
|
|
|
-- Three Phase Group
|
|
|
|
--
|
|
-- Reset Max/Min Values Group
|
|
--
|
|
|
|
upsPhaseResetMaxMinValues OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the maximum and minimum UPS values:
|
|
upsPhaseInputMaxVoltage, upsPhaseInputMinVoltage,
|
|
upsPhaseInputMaxCurrent, upsPhaseInputMinCurrent,
|
|
upsPhaseInputMaxPower, upsPhaseInputMinPower,
|
|
upsPhaseOutputMaxCurrent, upsPhaseOutputMinCurrent,
|
|
upsPhaseOutputMaxLoad, upsPhaseOutputMinLoad,
|
|
upsPhaseOutputMaxPercentLoad, upsPhaseOutputMinPercentLoad,
|
|
upsPhaseOutputMaxPower, upsPhaseOutputMinPower,
|
|
upsPhaseOutputMaxPercentPower, upsPhaseOutputMinPercentPower."
|
|
::= { upsPhaseResetValues 1 }
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
-- Number of Inputs
|
|
|
|
upsPhaseNumInputs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input feeds to this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { upsPhaseInput 1 }
|
|
|
|
-- Input Table
|
|
|
|
upsPhaseInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsPhaseInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of upsPhaseNumInputs."
|
|
::= { upsPhaseInput 2 }
|
|
|
|
upsPhaseInputEntry OBJECT-TYPE
|
|
SYNTAX UpsPhaseInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input."
|
|
INDEX { upsPhaseInputTableIndex }
|
|
::= { upsPhaseInputTable 1 }
|
|
|
|
UpsPhaseInputEntry ::= SEQUENCE {
|
|
upsPhaseInputTableIndex INTEGER,
|
|
upsPhaseNumInputPhases INTEGER,
|
|
upsPhaseInputVoltageOrientation INTEGER,
|
|
upsPhaseInputFrequency INTEGER,
|
|
upsPhaseInputType INTEGER,
|
|
upsPhaseInputName DisplayString
|
|
}
|
|
|
|
upsPhaseInputTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input identifier."
|
|
::= { upsPhaseInputEntry 1 }
|
|
|
|
upsPhaseNumInputPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input phases utilized in this
|
|
device. The sum of all the upsPhaseNumInputPhases
|
|
variable indicates the number of rows in the
|
|
input phase table."
|
|
::= { upsPhaseInputEntry 2 }
|
|
|
|
upsPhaseInputVoltageOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
singlePhase(2),
|
|
splitPhase(3),
|
|
threePhasePhaseToNeutral(4),
|
|
threePhasePhaseToPhase(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input voltage orientation:
|
|
1: unknown for this UPS
|
|
2: singlePhase - phase 1 voltage is between Phase 1
|
|
and Neutral.
|
|
3: splitPhase - phase 1 voltage is between Phase 1 and
|
|
Neutral; phase 2 voltage is between Phase 2 and Neutral;
|
|
phase 3 voltage is between Phase 1 and Phase 2.
|
|
4: threePhasePhaseToNeutral - phase 1 voltage is between
|
|
Phase 1 and Neutral; phase 2 voltage is between Phase 2
|
|
and Neutral; phase 3 voltage is between Phase 3 and
|
|
Neutral.
|
|
5: threePhasePhaseToPhase - phase 1 voltage is between
|
|
Phase 1 and Phase 2; phase 2 voltage is between Phase 2
|
|
and Phase 3; phase 3 voltage is between Phase 3 and
|
|
Phase 1."
|
|
::= { upsPhaseInputEntry 3 }
|
|
|
|
upsPhaseInputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input frequency in 0.1 Hertz, or -1 if it's unsupported
|
|
by this UPS."
|
|
::= { upsPhaseInputEntry 4 }
|
|
|
|
upsPhaseInputType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
main(2),
|
|
bypass(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input type."
|
|
::= { upsPhaseInputEntry 5 }
|
|
|
|
upsPhaseInputName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A name given to a particular input."
|
|
::= { upsPhaseInputEntry 6 }
|
|
|
|
-- Input Phase Table
|
|
|
|
upsPhaseInputPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsPhaseInputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the sum of the upsPhaseNumInputPhases."
|
|
::= { upsPhaseInput 3 }
|
|
|
|
upsPhaseInputPhaseEntry OBJECT-TYPE
|
|
SYNTAX UpsPhaseInputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input phase."
|
|
INDEX { upsPhaseInputPhaseTableIndex, upsPhaseInputPhaseIndex }
|
|
::= { upsPhaseInputPhaseTable 1 }
|
|
|
|
UpsPhaseInputPhaseEntry ::= SEQUENCE {
|
|
upsPhaseInputPhaseTableIndex INTEGER,
|
|
upsPhaseInputPhaseIndex INTEGER,
|
|
upsPhaseInputVoltage INTEGER,
|
|
upsPhaseInputMaxVoltage INTEGER,
|
|
upsPhaseInputMinVoltage INTEGER,
|
|
upsPhaseInputCurrent INTEGER,
|
|
upsPhaseInputMaxCurrent INTEGER,
|
|
upsPhaseInputMinCurrent INTEGER,
|
|
upsPhaseInputPower INTEGER,
|
|
upsPhaseInputMaxPower INTEGER,
|
|
upsPhaseInputMinPower INTEGER,
|
|
upsPhaseInputApparentPower INTEGER,
|
|
upsPhaseInputPowerFactor INTEGER
|
|
}
|
|
|
|
upsPhaseInputPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input identifier."
|
|
::= { upsPhaseInputPhaseEntry 1 }
|
|
|
|
upsPhaseInputPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input phase identifier."
|
|
::= { upsPhaseInputPhaseEntry 2 }
|
|
|
|
upsPhaseInputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input voltage in VAC, or -1 if it's unsupported
|
|
by this UPS."
|
|
::= { upsPhaseInputPhaseEntry 3 }
|
|
|
|
upsPhaseInputMaxVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum input voltage in VAC measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseInputPhaseEntry 4 }
|
|
|
|
upsPhaseInputMinVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum input voltage in VAC measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseInputPhaseEntry 5 }
|
|
|
|
upsPhaseInputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input current in 0.1 amperes, or -1 if it's
|
|
unsupported by this UPS."
|
|
::= { upsPhaseInputPhaseEntry 6 }
|
|
|
|
upsPhaseInputMaxCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum input current in 0.1 amperes measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseInputPhaseEntry 7 }
|
|
|
|
upsPhaseInputMinCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum input current in 0.1 amperes measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseInputPhaseEntry 8 }
|
|
|
|
upsPhaseInputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input power in Watts, or -1 if it's unsupported
|
|
by this UPS."
|
|
::= { upsPhaseInputPhaseEntry 9 }
|
|
|
|
upsPhaseInputMaxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum input power in Watts measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseInputPhaseEntry 10 }
|
|
|
|
upsPhaseInputMinPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum input power in Watts measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseInputPhaseEntry 11 }
|
|
|
|
|
|
upsPhaseInputApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input apparent power of the UPS in kVA."
|
|
::= { upsPhaseInputPhaseEntry 12 }
|
|
|
|
|
|
upsPhaseInputPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input power factor measured in hundredth."
|
|
::= { upsPhaseInputPhaseEntry 13 }
|
|
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
-- Number of Outputs
|
|
|
|
upsPhaseNumOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output feeds to this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { upsPhaseOutput 1 }
|
|
|
|
-- Output Table
|
|
|
|
upsPhaseOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsPhaseOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of entries
|
|
is given by the value of upsOutputNumPhases."
|
|
::= { upsPhaseOutput 2 }
|
|
|
|
upsPhaseOutputEntry OBJECT-TYPE
|
|
SYNTAX UpsPhaseOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output."
|
|
INDEX { upsPhaseOutputTableIndex }
|
|
::= { upsPhaseOutputTable 1 }
|
|
|
|
UpsPhaseOutputEntry ::= SEQUENCE {
|
|
upsPhaseOutputTableIndex INTEGER,
|
|
upsPhaseNumOutputPhases INTEGER,
|
|
upsPhaseOutputVoltageOrientation INTEGER,
|
|
upsPhaseOutputFrequency INTEGER
|
|
}
|
|
|
|
upsPhaseOutputTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output identifier."
|
|
::= { upsPhaseOutputEntry 1 }
|
|
|
|
upsPhaseNumOutputPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output phases utilized in this
|
|
device. The sum of all the upsPhaseNumOutputPhases
|
|
variable indicates the number of rows in the
|
|
output phase table."
|
|
::= { upsPhaseOutputEntry 2 }
|
|
|
|
upsPhaseOutputVoltageOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
singlePhase(2),
|
|
splitPhase(3),
|
|
threePhasePhaseToNeutral(4),
|
|
threePhasePhaseToPhase(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output voltage orientation:
|
|
1: unknown for this UPS
|
|
2: singlePhase - phase 1 voltage is between Phase 1
|
|
and Neutral.
|
|
3: splitPhase - phase 1 voltage is between Phase 1 and
|
|
Neutral; phase 2 voltage is between Phase 2 and Neutral;
|
|
phase 3 voltage is between Phase 1 and Phase 2.
|
|
4: threePhasePhaseToNeutral - phase 1 voltage is between
|
|
Phase 1 and Neutral; phase 2 voltage is between Phase 2
|
|
and Neutral; phase 3 voltage is between Phase 3 and
|
|
Neutral.
|
|
5: threePhasePhaseToPhase - phase 1 voltage is between
|
|
Phase 1 and Phase 2; phase 2 voltage is between Phase 2
|
|
and Phase 3; phase 3 voltage is between Phase 3 and
|
|
Phase 1."
|
|
::= { upsPhaseOutputEntry 3 }
|
|
|
|
upsPhaseOutputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output frequency in 0.1 Hertz, or -1 if it's
|
|
unsupported by this UPS."
|
|
::= { upsPhaseOutputEntry 4 }
|
|
|
|
-- Output Phase Table
|
|
|
|
upsPhaseOutputPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsPhaseOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the sum of the upsPhaseNumOutputPhases."
|
|
::= { upsPhaseOutput 3 }
|
|
|
|
upsPhaseOutputPhaseEntry OBJECT-TYPE
|
|
SYNTAX UpsPhaseOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output phase."
|
|
INDEX { upsPhaseOutputPhaseTableIndex, upsPhaseOutputPhaseIndex }
|
|
::= { upsPhaseOutputPhaseTable 1 }
|
|
|
|
UpsPhaseOutputPhaseEntry ::= SEQUENCE {
|
|
upsPhaseOutputPhaseTableIndex INTEGER,
|
|
upsPhaseOutputPhaseIndex INTEGER,
|
|
upsPhaseOutputVoltage INTEGER,
|
|
upsPhaseOutputCurrent INTEGER,
|
|
upsPhaseOutputMaxCurrent INTEGER,
|
|
upsPhaseOutputMinCurrent INTEGER,
|
|
upsPhaseOutputLoad INTEGER,
|
|
upsPhaseOutputMaxLoad INTEGER,
|
|
upsPhaseOutputMinLoad INTEGER,
|
|
upsPhaseOutputPercentLoad INTEGER,
|
|
upsPhaseOutputMaxPercentLoad INTEGER,
|
|
upsPhaseOutputMinPercentLoad INTEGER,
|
|
upsPhaseOutputPower INTEGER,
|
|
upsPhaseOutputMaxPower INTEGER,
|
|
upsPhaseOutputMinPower INTEGER,
|
|
upsPhaseOutputPercentPower INTEGER,
|
|
upsPhaseOutputMaxPercentPower INTEGER,
|
|
upsPhaseOutputMinPercentPower INTEGER,
|
|
upsPhaseOutputPowerFactor INTEGER
|
|
}
|
|
|
|
upsPhaseOutputPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output identifier."
|
|
::= { upsPhaseOutputPhaseEntry 1 }
|
|
|
|
upsPhaseOutputPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output phase identifier."
|
|
::= { upsPhaseOutputPhaseEntry 2 }
|
|
|
|
upsPhaseOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output voltage in VAC, or -1 if it's unsupported
|
|
by this UPS."
|
|
::= { upsPhaseOutputPhaseEntry 3 }
|
|
|
|
upsPhaseOutputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output current in 0.1 amperes drawn
|
|
by the load on the UPS, or -1 if it's unsupported
|
|
by this UPS."
|
|
::= { upsPhaseOutputPhaseEntry 4 }
|
|
|
|
upsPhaseOutputMaxCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum output current in 0.1 amperes measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseOutputPhaseEntry 5 }
|
|
|
|
upsPhaseOutputMinCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum output current in 0.1 amperes measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseOutputPhaseEntry 6 }
|
|
|
|
upsPhaseOutputLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output load in VA, or -1 if it's unsupported
|
|
by this UPS."
|
|
::= { upsPhaseOutputPhaseEntry 7 }
|
|
|
|
upsPhaseOutputMaxLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum output load in VA measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseOutputPhaseEntry 8 }
|
|
|
|
upsPhaseOutputMinLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum output load in VA measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseOutputPhaseEntry 9 }
|
|
|
|
upsPhaseOutputPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percentage of the UPS load capacity in VA at
|
|
redundancy @ (n + x) presently being used on this
|
|
output phase, or -1 if it's unsupported by this UPS."
|
|
::= { upsPhaseOutputPhaseEntry 10 }
|
|
|
|
upsPhaseOutputMaxPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum percentage of the UPS load capacity in
|
|
VA measured at redundancy @ (n + x) presently
|
|
being used on this output phase since the last reset
|
|
(upsPhaseResetMaxMinValues), or -1 if it's unsupported
|
|
by this UPS. Sampled every 30 seconds."
|
|
::= { upsPhaseOutputPhaseEntry 11 }
|
|
|
|
upsPhaseOutputMinPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum percentage of the UPS load capacity in
|
|
VA measured at redundancy @ (n + x) presently
|
|
being used on this output phase since the last reset
|
|
(upsPhaseResetMaxMinValues), or -1 if it's unsupported
|
|
by this UPS. Sampled every 30 seconds."
|
|
::= { upsPhaseOutputPhaseEntry 12 }
|
|
|
|
upsPhaseOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output power in Watts, or -1 if it's
|
|
unsupported by this UPS."
|
|
::= { upsPhaseOutputPhaseEntry 13 }
|
|
|
|
upsPhaseOutputMaxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum output power in Watts measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseOutputPhaseEntry 14 }
|
|
|
|
upsPhaseOutputMinPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum output power in Watts measured
|
|
since the last reset (upsPhaseResetMaxMinValues), or
|
|
-1 if it's unsupported by this UPS.
|
|
Sampled every 30 seconds."
|
|
::= { upsPhaseOutputPhaseEntry 15 }
|
|
|
|
upsPhaseOutputPercentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity in Watts at
|
|
redundancy @ (n + x) presently being used on this
|
|
output phase, or -1 if it's unsupported by this UPS."
|
|
::= { upsPhaseOutputPhaseEntry 16 }
|
|
|
|
upsPhaseOutputMaxPercentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum percentage of the UPS power capacity
|
|
in Watts measured at redundancy @ (n + x) presently
|
|
being used on this output phase since the last
|
|
reset (upsPhaseResetMaxMinValues), or -1 if it's
|
|
unsupported by this UPS. Sampled every 30 seconds."
|
|
::= { upsPhaseOutputPhaseEntry 17 }
|
|
|
|
upsPhaseOutputMinPercentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum percentage of the UPS power capacity
|
|
in Watts measured at redundancy @ (n + x) presently
|
|
being used on this output phase since the last
|
|
reset (upsPhaseResetMaxMinValues), or -1 if it's
|
|
unsupported by this UPS. Sampled every 30 seconds."
|
|
::= { upsPhaseOutputPhaseEntry 18 }
|
|
|
|
upsPhaseOutputPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Output power factor of the UPS in hundredth."
|
|
::= { upsPhaseOutputPhaseEntry 19 }
|
|
|
|
-- the upsOutletGroupStatus group
|
|
|
|
upsOutletGroupStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of outlet groups for the UPS."
|
|
::= { upsOutletGroupStatus 1 }
|
|
|
|
upsOutletGroupStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsOutletGroupStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting status of the outlet groups. The number of
|
|
entries is contained in the upsOutletGroupStatusTableSize OID."
|
|
::= { upsOutletGroupStatus 2 }
|
|
|
|
upsOutletGroupStatusEntry OBJECT-TYPE
|
|
SYNTAX UpsOutletGroupStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet group status to get."
|
|
INDEX { upsOutletGroupStatusIndex}
|
|
::= { upsOutletGroupStatusTable 1 }
|
|
|
|
UpsOutletGroupStatusEntry ::=
|
|
SEQUENCE {
|
|
upsOutletGroupStatusIndex INTEGER,
|
|
upsOutletGroupStatusName DisplayString,
|
|
upsOutletGroupStatusGroupState INTEGER,
|
|
upsOutletGroupStatusCommandPending INTEGER,
|
|
upsOutletGroupStatusOutletType INTEGER
|
|
}
|
|
|
|
upsOutletGroupStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet group entry."
|
|
::= { upsOutletGroupStatusEntry 1 }
|
|
|
|
upsOutletGroupStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet group. This OID is provided
|
|
for informational purposes only. This value is set
|
|
by the upsOutletGroupConfigName OID."
|
|
::= { upsOutletGroupStatusEntry 2 }
|
|
|
|
upsOutletGroupStatusGroupState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsOutletGroupStatusOn (1),
|
|
upsOutletGroupStatusOff (2),
|
|
upsOutletGroupStatusUnknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet group state. If the outlet
|
|
group is on, the upsOutletGroupStatusOn (1) value will be returned. If
|
|
the outlet group is off, the upsOutletGroupStatusOff (2) value will be
|
|
returned. If the state of the outlet group cannot be determined, the
|
|
upsOutletGroupStatusUnknown (3) value will be returned."
|
|
|
|
::= { upsOutletGroupStatusEntry 3 }
|
|
|
|
upsOutletGroupStatusCommandPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsOutletGroupCommandPending (1),
|
|
upsOutletGroupNoCommandPending (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the command pending
|
|
state of the outlet group. If a command is pending on the
|
|
outlet group, the upsOutletGroupCommandPending (1) value
|
|
will be returned. If there is not a command pending
|
|
on the outlet group, the upsOutletGroupNoCommandPending (2)
|
|
will be returned."
|
|
::= { upsOutletGroupStatusEntry 4 }
|
|
|
|
upsOutletGroupStatusOutletType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsSwitchedOutletGroup (1),
|
|
upsMainOutletGroup (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the type of outlet group.
|
|
If present in the system, the main outlet group is
|
|
'unswitched' and must be on in order for any of the switched
|
|
outlet groups to be on. Conversely, if the main outlet group
|
|
is off, all the switched outlet groups must also be off.
|
|
Therefore, any commands made to the main outlet group that
|
|
turn it off will also be applied to all switched outlet
|
|
groups that are on, unless the state of a switched outlet
|
|
group prevents it, in which case the command will fail."
|
|
::= { upsOutletGroupStatusEntry 5 }
|
|
|
|
-- the upsOutletGroupConfig group
|
|
|
|
upsOutletGroupConfigTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of outlet groups for the UPS."
|
|
::= { upsOutletGroupConfig 1 }
|
|
|
|
upsOutletGroupConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsOutletGroupConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The list of outlet groups to configure. The number of entries
|
|
is defined by the upsOutletGroupConfigTableSize OID."
|
|
::= { upsOutletGroupConfig 2 }
|
|
|
|
upsOutletGroupConfigEntry OBJECT-TYPE
|
|
SYNTAX UpsOutletGroupConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet groups to configure."
|
|
INDEX { upsOutletGroupConfigIndex}
|
|
::= { upsOutletGroupConfigTable 1 }
|
|
|
|
UpsOutletGroupConfigEntry ::=
|
|
SEQUENCE {
|
|
upsOutletGroupConfigIndex INTEGER,
|
|
upsOutletGroupConfigName DisplayString,
|
|
upsOutletGroupConfigPowerOnDelay INTEGER,
|
|
upsOutletGroupConfigPowerOffDelay INTEGER,
|
|
upsOutletGroupConfigRebootDuration INTEGER,
|
|
upsOutletGroupConfigMinReturnRuntime INTEGER,
|
|
upsOutletGroupConfigOutletType INTEGER,
|
|
upsOutletGroupConfigLoadShedControlSkipOffDelay INTEGER,
|
|
upsOutletGroupConfigLoadShedControlAutoRestart INTEGER,
|
|
upsOutletGroupConfigLoadShedControlTimeOnBattery INTEGER,
|
|
upsOutletGroupConfigLoadShedControlRuntimeRemaining INTEGER,
|
|
upsOutletGroupConfigLoadShedControlInOverload INTEGER,
|
|
upsOutletGroupConfigLoadShedTimeOnBattery INTEGER,
|
|
upsOutletGroupConfigLoadShedRuntimeRemaining INTEGER
|
|
}
|
|
|
|
upsOutletGroupConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet group entry."
|
|
::= { upsOutletGroupConfigEntry 1 }
|
|
|
|
upsOutletGroupConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet group."
|
|
::= { upsOutletGroupConfigEntry 2 }
|
|
|
|
upsOutletGroupConfigPowerOnDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (seconds) the outlet group will delay
|
|
powering on when the delayed on, reboot, or shutdown command is
|
|
applied. Allowed values vary by UPS model. The value of -1 is
|
|
used for Never if supported by the UPS and the outlet group."
|
|
::= { upsOutletGroupConfigEntry 3 }
|
|
|
|
upsOutletGroupConfigPowerOffDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (seconds) the outlet group will delay
|
|
powering off when the delayed off, reboot, or shutdown command is
|
|
applied. Allowed values vary by UPS model. The value of -1 is
|
|
used for Never if supported by the UPS and the outlet group."
|
|
::= { upsOutletGroupConfigEntry 4 }
|
|
|
|
upsOutletGroupConfigRebootDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"During a reboot sequence, power is turned off and then
|
|
back on. This OID defines the amount of time to wait
|
|
(seconds) after turning the power off, at the start
|
|
of the sequence, before initiating the power on sequence.
|
|
Allowed values vary by UPS model."
|
|
::= { upsOutletGroupConfigEntry 5 }
|
|
|
|
upsOutletGroupConfigMinReturnRuntime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"In an Outlet Group shutdown sequence, the Outlet Group cycles
|
|
power off then on. This OID defines the minimum amount of UPS
|
|
runtime (seconds) that is required in order to power the
|
|
Outlet Group on. Allowed values vary by UPS model."
|
|
::= { upsOutletGroupConfigEntry 6 }
|
|
|
|
upsOutletGroupConfigOutletType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsSwitchedOutletGroup (1),
|
|
upsMainOutletGroup (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the type of outlet group.
|
|
If present in the system, the main outlet group is
|
|
'unswitched' and must be on in order for any of the switched
|
|
outlet groups to be on. Conversely, if the main outlet group
|
|
is off, all the switched outlet groups must also be off.
|
|
Therefore, any commands made to the main outlet group that
|
|
turn it off will also be applied to all switched outlet
|
|
groups that are on, unless the state of a switched outlet
|
|
group prevents it, in which case the command will fail."
|
|
::= { upsOutletGroupConfigEntry 7 }
|
|
|
|
upsOutletGroupConfigLoadShedControlSkipOffDelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsOutletGroupConfigSkipOffDelay (1),
|
|
upsOutletGroupConfigUseOffDelay (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configures whether the outlet group's off delay setting
|
|
(upsOutletGroupConfigPowerOffDelay) will be used in a load
|
|
shedding situation, where applicable."
|
|
::= { upsOutletGroupConfigEntry 8 }
|
|
|
|
upsOutletGroupConfigLoadShedControlAutoRestart OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsOutletGroupConfigAutoRestart (1),
|
|
upsOutletGroupConfigManualRestart (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configures whether the outlet group will automatically restart
|
|
after a load shedding situation, where applicable."
|
|
::= { upsOutletGroupConfigEntry 9 }
|
|
|
|
upsOutletGroupConfigLoadShedControlTimeOnBattery OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsOutletGroupConfigDisableTimeOnBatteryLoadShed (1),
|
|
upsOutletGroupConfigEnableTimeOnBatteryLoadShed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configures whether the outlet group will load shed (turn off)
|
|
after the UPS's time on battery has exceeded the
|
|
upsOutletGroupConfigLoadShedTimeOnBattery OID setting. The
|
|
settings for upsOutletGroupConfigLoadShedControlSkipOffDelay
|
|
and upsOutletGroupConfigLoadShedControlAutoRestart are valid
|
|
for this load shed condition."
|
|
::= { upsOutletGroupConfigEntry 10 }
|
|
|
|
upsOutletGroupConfigLoadShedControlRuntimeRemaining OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsOutletGroupConfigDisableRuntimeRemainingLoadShed (1),
|
|
upsOutletGroupConfigEnableRuntimeRemainingLoadShed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configures whether the outlet group will load shed (turn off)
|
|
when the UPS is on battery and the remaining runtime is less
|
|
than the upsOutletGroupConfigLoadShedRuntimeRemaining OID
|
|
setting. The settings for
|
|
upsOutletGroupConfigLoadShedControlSkipOffDelay and
|
|
upsOutletGroupConfigLoadShedControlAutoRestart are valid for
|
|
this load shed condition."
|
|
::= { upsOutletGroupConfigEntry 11 }
|
|
|
|
upsOutletGroupConfigLoadShedControlInOverload OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsOutletGroupConfigDisableInOverloadLoadShed (1),
|
|
upsOutletGroupConfigEnableInOverloadLoadShed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configures whether the outlet group will load shed (turn off)
|
|
when the UPS is in an overload condition. The setting for
|
|
upsOutletGroupConfigLoadShedControlSkipOffDelay is valid for
|
|
this load shed condition. Returns -1 if not supported by this
|
|
outlet group."
|
|
::= { upsOutletGroupConfigEntry 12 }
|
|
|
|
upsOutletGroupConfigLoadShedTimeOnBattery OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the UPS has been on battery for more time than this
|
|
value, the outlet group will turn off if this condition is
|
|
enabled by the upsOutletGroupConfigLoadShedControlTimeOnBattery
|
|
OID. Allowed values vary by UPS model."
|
|
::= { upsOutletGroupConfigEntry 13 }
|
|
|
|
upsOutletGroupConfigLoadShedRuntimeRemaining OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the runtime remaining is less than this value, the outlet
|
|
group will turn off if this condition is enabled by the
|
|
upsOutletGroupConfigLoadShedControlRuntimeRemaining OID.
|
|
Allowed values vary by UPS model."
|
|
::= { upsOutletGroupConfigEntry 14 }
|
|
|
|
-- the upsOutletGroupControl group
|
|
|
|
upsOutletGroupControlTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of outlet groups for the UPS."
|
|
::= { upsOutletGroupControl 1 }
|
|
|
|
upsOutletGroupControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsOutletGroupControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of individual outlet groups. The number of
|
|
entries is contained in the upsOutletGroupControlTableSize OID."
|
|
::= { upsOutletGroupControl 2 }
|
|
|
|
upsOutletGroupControlEntry OBJECT-TYPE
|
|
SYNTAX UpsOutletGroupControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet group to control."
|
|
INDEX { upsOutletGroupControlIndex}
|
|
::= { upsOutletGroupControlTable 1 }
|
|
|
|
UpsOutletGroupControlEntry ::=
|
|
SEQUENCE {
|
|
upsOutletGroupControlIndex INTEGER,
|
|
upsOutletGroupControlName DisplayString,
|
|
upsOutletGroupControlCommand INTEGER,
|
|
upsOutletGroupControlOutletType INTEGER
|
|
}
|
|
|
|
upsOutletGroupControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet group entry."
|
|
::= { upsOutletGroupControlEntry 1 }
|
|
|
|
upsOutletGroupControlName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet group. This OID is provided
|
|
for informational purposes only. This value is set
|
|
by the upsOutletGroupConfigName OID."
|
|
::= { upsOutletGroupControlEntry 2 }
|
|
|
|
upsOutletGroupControlCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsOutletGroupImmediateOn (1),
|
|
upsOutletGroupImmediateOff (2),
|
|
upsOutletGroupImmediateRebootWithOrWithoutAC (3),
|
|
upsOutletGroupDelayedOn (4),
|
|
upsOutletGroupDelayedOff (5),
|
|
upsOutletGroupDelayedRebootWithOrWithoutAC (6),
|
|
upsOutletGroupCancelPendingCommand (7),
|
|
upsOutletGroupControlUnknown (8),
|
|
upsOutletGroupImmediateRebootShutdown (9),
|
|
upsOutletGroupDelayedRebootShutdown (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet group state. If the outlet
|
|
group is on, the upsOutletGroupImmediateOn (1) value will be returned. If
|
|
the outlet group is off, the upsOutletGroupImmediateOff (2) value will be
|
|
returned.
|
|
|
|
If the state of the outlet group cannot be determined, the
|
|
upsOutletGroupControlUnknown (8) value will be returned.
|
|
|
|
Setting this variable to upsOutletGroupImmediateOn (1) will turn the
|
|
outlet group on immediately.
|
|
|
|
Setting this variable to upsOutletGroupImmediateOff (2) will turn the
|
|
outlet group off immediately.
|
|
|
|
Setting this variable to upsOutletGroupImmediateRebootWithOrWithoutAC (3)
|
|
will turn the outlet group off immediately, wait the
|
|
upsOutletGroupConfigRebootDuration OID time, wait the
|
|
upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group on
|
|
regardless of the AC input power on the UPS.
|
|
|
|
Setting this variable to upsOutletGroupDelayedOn (4) will turn the outlet
|
|
group on after the upsOutletGroupConfigPowerOnDelay OID has elapsed.
|
|
|
|
Setting this variable to upsOutletGroupDelayedOff (5) will turn the outlet
|
|
group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed.
|
|
|
|
Setting this variable to upsOutletGroupDelayedRebootWithOrWithoutAC (6)
|
|
will turn the outlet group off after the upsOutletGroupConfigPowerOffDelay
|
|
OID has elapsed, wait the upsOutletGroupConfigRebootDuration OID time, wait
|
|
the upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group
|
|
on regardless of the AC input power on the UPS.
|
|
|
|
Setting this variable to upsOutletGroupCancelPendingCommand (7) will
|
|
cause any pending command to this outlet group to be canceled.
|
|
|
|
Setting this variable to upsOutletGroupImmediateRebootShutdown (9) will
|
|
turn the outlet group off immediately, wait for the AC power to return to normal
|
|
(a minimum of the upsOutletGroupConfigRebootDuration OID time), wait the
|
|
upsOutletGroupConfigPowerOnDelay OID time, and then turn the outlet
|
|
group on.
|
|
|
|
Setting this variable to upsOutletGroupDelayedRebootShutdown (10) will
|
|
turn the outlet group off after the upsOutletGroupConfigPowerOffDelay OID
|
|
has elapsed, wait for the AC power to return to normal (a minimum of the
|
|
upsOutletGroupConfigRebootDuration OID time), wait the
|
|
upsOutletGroupConfigPowerOnDelay OID time, and then turn the outlet
|
|
group on.
|
|
|
|
In systems with a main outlet group, commands to the main outlet group must
|
|
be performed with caution. It may be clearer to use the ups control commands
|
|
available from upsAdvControl... OIDs. If any command is made to the main
|
|
outlet group that will turn it off, one of two things will happen:
|
|
1) If any switched outlet group is in a state that prevents this command
|
|
from occurring on the main outlet group, the command will be rejected. Note
|
|
that a switched outlet group being on without a command in progress is not a
|
|
state that normally prevents the command.
|
|
2) The command will be accepted and applied to the main outlet group and all
|
|
switched outlet groups that are on.
|
|
|
|
There is one additional special case for systems with a main outlet group.
|
|
If the main outlet group is off and a switched outlet group is commanded to
|
|
turn on, the on command will be applied to both the main outlet group and
|
|
that switched outlet group."
|
|
::= { upsOutletGroupControlEntry 3 }
|
|
|
|
upsOutletGroupControlOutletType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsSwitchedOutletGroup (1),
|
|
upsMainOutletGroup (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the type of outlet group.
|
|
If present in the system, the main outlet group is
|
|
'unswitched' and must be on in order for any of the switched
|
|
outlet groups to be on. Conversely, if the main outlet group
|
|
is off, all the switched outlet groups must also be off.
|
|
Therefore, any commands made to the main outlet group that
|
|
turn it off will also be applied to all switched outlet
|
|
groups that are on, unless the state of a switched outlet
|
|
group prevents it, in which case the command will fail."
|
|
::= { upsOutletGroupControlEntry 4 }
|
|
|
|
-- the upsDiagnosticIM group
|
|
|
|
upsDiagIMTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Intelligence Modules in or attached to the UPS."
|
|
::= { upsDiagnosticIM 1 }
|
|
|
|
upsDiagIMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagIMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual Intelligence Modules. The number of
|
|
entries is contained in the upsDiagIMTableSize OID."
|
|
::= { upsDiagnosticIM 2 }
|
|
|
|
upsDiagIMEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagIMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics and information of an Intelligence Module."
|
|
INDEX { upsDiagIMIndex}
|
|
::= { upsDiagIMTable 1 }
|
|
|
|
UpsDiagIMEntry ::=
|
|
SEQUENCE {
|
|
upsDiagIMIndex INTEGER,
|
|
upsDiagIMType INTEGER,
|
|
upsDiagIMStatus INTEGER,
|
|
upsDiagIMFirmwareRev DisplayString,
|
|
upsDiagIMSlaveFirmwareRev DisplayString,
|
|
upsDiagIMHardwareRev DisplayString,
|
|
upsDiagIMSerialNum DisplayString,
|
|
upsDiagIMManufactureDate DisplayString
|
|
}
|
|
|
|
upsDiagIMIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Intelligence Module entry."
|
|
::= { upsDiagIMEntry 1 }
|
|
|
|
upsDiagIMType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
imUnknown (1),
|
|
imMIM (2),
|
|
imRIM (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the Intelligence Module.
|
|
imUnknown(1) indicates the IM type is unknown.
|
|
imMIM(2) indicates the IM type is a Main Intelligence Module.
|
|
imRIM(3) indicates the IM type is Redundant Intelligence Module."
|
|
::= { upsDiagIMEntry 2 }
|
|
|
|
upsDiagIMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Intelligence Module.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagIMEntry 3 }
|
|
|
|
upsDiagIMFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the Intelligence Module."
|
|
::= { upsDiagIMEntry 4 }
|
|
|
|
upsDiagIMSlaveFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The slave firmware revision of the Intelligence Module."
|
|
::= { upsDiagIMEntry 5 }
|
|
|
|
upsDiagIMHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Intelligence Module."
|
|
::= { upsDiagIMEntry 6 }
|
|
|
|
upsDiagIMSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the Intelligence Module."
|
|
::= { upsDiagIMEntry 7 }
|
|
|
|
upsDiagIMManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The manufacture date of the Intelligence Module."
|
|
::= { upsDiagIMEntry 8 }
|
|
|
|
-- the upsDiagnosticPowerModules group
|
|
|
|
upsDiagPMTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of Power Modules supported by the UPS."
|
|
::= { upsDiagnosticPowerModules 1 }
|
|
|
|
upsDiagPMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagPMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of Individual Power modules. The number of
|
|
entries is contained in the upsDiagPMTableSize OID."
|
|
::= { upsDiagnosticPowerModules 2 }
|
|
|
|
upsDiagPMEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagPMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of an Power Module."
|
|
INDEX { upsDiagPMIndex}
|
|
::= { upsDiagPMTable 1 }
|
|
|
|
UpsDiagPMEntry ::=
|
|
SEQUENCE {
|
|
upsDiagPMIndex INTEGER,
|
|
upsDiagPMStatus INTEGER,
|
|
upsDiagPMFirmwareRev DisplayString,
|
|
upsDiagPMHardwareRev DisplayString,
|
|
upsDiagPMSerialNum DisplayString,
|
|
upsDiagPMManufactureDate DisplayString
|
|
}
|
|
|
|
upsDiagPMIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Power Module entry."
|
|
::= { upsDiagPMEntry 1 }
|
|
|
|
upsDiagPMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Power Module.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagPMEntry 2 }
|
|
|
|
upsDiagPMFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the Power Module."
|
|
::= { upsDiagPMEntry 3 }
|
|
|
|
upsDiagPMHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Power Module."
|
|
::= { upsDiagPMEntry 4 }
|
|
|
|
upsDiagPMSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the Power Module."
|
|
::= { upsDiagPMEntry 5 }
|
|
|
|
upsDiagPMManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The manufacture date of the Power Module."
|
|
::= { upsDiagPMEntry 6 }
|
|
|
|
upsDiagPMLifetimeInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagPMLifetimeInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual power module's lifetime information.
|
|
The number of entries is contained in the upsDiagPMTableSize OID."
|
|
::= { upsDiagnosticPowerModules 3 }
|
|
|
|
upsDiagPMLifetimeInfoEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagPMLifetimeInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of a Power Module lifetime information."
|
|
INDEX { upsDiagPMLifetimeInfoIndex}
|
|
::= { upsDiagPMLifetimeInfoTable 1 }
|
|
|
|
UpsDiagPMLifetimeInfoEntry ::=
|
|
SEQUENCE {
|
|
upsDiagPMLifetimeInfoIndex INTEGER,
|
|
upsDiagPMLifetimeStatus INTEGER,
|
|
upsDiagPMEstmtdLifetimeRmng INTEGER,
|
|
upsDiagPMEstmtdLifetimeRmngPct INTEGER,
|
|
upsDiagPMFanLifetimeStatus INTEGER,
|
|
upsDiagPMFanEstmtdLifetimeRmng INTEGER,
|
|
upsDiagPMFanEstmtdLifetimeRmngPct INTEGER
|
|
|
|
}
|
|
|
|
upsDiagPMLifetimeInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Power Module lifetime information entry."
|
|
::= { upsDiagPMLifetimeInfoEntry 1 }
|
|
|
|
upsDiagPMLifetimeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok (1),
|
|
nearEnd (2),
|
|
exceeded (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Power Module lifetime information.
|
|
ok(1) indicates the device lifetime status is OK.
|
|
nearEnd(2) indicates the device lifetime status is near end.
|
|
exceeded(3) indicates the device lifetime status is exceeded.
|
|
unknown(4) indicates the device lifetime status is unknown."
|
|
|
|
::= { upsDiagPMLifetimeInfoEntry 2 }
|
|
|
|
upsDiagPMEstmtdLifetimeRmng OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Displays the time remaining for the module before it should be replaced.
|
|
Measured in months. This value is set when you originally install the module."
|
|
::= { upsDiagPMLifetimeInfoEntry 3 }
|
|
|
|
upsDiagPMEstmtdLifetimeRmngPct OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Displays the percentage of the total lifetime remaining for the module
|
|
before it should be replaced."
|
|
::= { upsDiagPMLifetimeInfoEntry 4 }
|
|
|
|
upsDiagPMFanLifetimeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok (1),
|
|
nearEnd (2),
|
|
exceeded (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Power Module Fan lifetime information.
|
|
ok(1) indicates the device lifetime status is OK.
|
|
nearEnd(2) indicates the device lifetime status is near end.
|
|
exceeded(3) indicates the device lifetime status is exceeded.
|
|
unknown(4) indicates the device lifetime status is unknown."
|
|
::= { upsDiagPMLifetimeInfoEntry 5 }
|
|
|
|
upsDiagPMFanEstmtdLifetimeRmng OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Displays the time remaining, measured in months, before the module's
|
|
fan should be replaced. It is reset by the field service engineer when
|
|
a new fan is installed."
|
|
::= { upsDiagPMLifetimeInfoEntry 6 }
|
|
|
|
upsDiagPMFanEstmtdLifetimeRmngPct OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Displays the percentage of the total lifetime remaining
|
|
before the module's fan should be replaced."
|
|
::= { upsDiagPMLifetimeInfoEntry 7 }
|
|
|
|
upsDiagPMEnclDoorFltrTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of power module enclosures attached to the UPS."
|
|
::= { upsDiagnosticPowerModules 4 }
|
|
|
|
upsDiagPMEnclDoorFltrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagPMEnclDoorFltrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for the diagnostics of individual power module enclosure door filters.
|
|
The number of entries is contained in the upsDiagPMEnclDoorFltrTableSize OID."
|
|
::= { upsDiagnosticPowerModules 5 }
|
|
|
|
upsDiagPMEnclDoorFltrEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagPMEnclDoorFltrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module door filter diagnostics info."
|
|
INDEX { upsDiagPMEnclIndex}
|
|
::= { upsDiagPMEnclDoorFltrTable 1 }
|
|
|
|
UpsDiagPMEnclDoorFltrEntry ::=
|
|
SEQUENCE {
|
|
upsDiagPMEnclIndex INTEGER,
|
|
upsDiagPMEnclDoorFltrLifetime INTEGER,
|
|
upsDiagPMEnclDoorFltrStatus INTEGER,
|
|
upsDiagPMEnclDoorFltrEstmtdLifetimeRmng INTEGER,
|
|
upsDiagPMEnclDoorFltrEstmtdLifetimeRmngPct INTEGER
|
|
}
|
|
upsDiagPMEnclIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the power module enclosure entry.
|
|
Enclosure 0 indicates the Power enclosure 1.
|
|
Enclosure 1 indicates the Power enclosure 2."
|
|
::= { upsDiagPMEnclDoorFltrEntry 1 }
|
|
|
|
upsDiagPMEnclDoorFltrLifetime OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
heavyFiltration15days (1),
|
|
normalFiltration30days(2),
|
|
lightFiltration60days (3),
|
|
notPresent (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Door filter replacement time interval, based on the installation enivironment.
|
|
heavyFiltration15days (1) indicates door filter needs to be replaced within 15 days.
|
|
normalFiltration30days (2) indicates door filter needs to be replaced within 30 days.
|
|
lightFiltration60days (3) indicates door filter needs to be replaced within 60 days.
|
|
notPresent(4) indicates that the door filter is not present."
|
|
::= { upsDiagPMEnclDoorFltrEntry 2 }
|
|
|
|
upsDiagPMEnclDoorFltrStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok (1),
|
|
nearEnd (2),
|
|
exceeded (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the current status of the door filter.
|
|
ok(1) indicates the device lifetime status is OK.
|
|
nearEnd(2) indicates the device lifetime status is near end.
|
|
exceeded(3) indicates the device lifetime status is exceeded.
|
|
unknown(4) indicates the device lifetime status is unknown."
|
|
::= { upsDiagPMEnclDoorFltrEntry 3 }
|
|
|
|
upsDiagPMEnclDoorFltrEstmtdLifetimeRmng OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Displays the time remaining, measured in days, before the module door filter should be replaced.
|
|
This value is set when you originally install the module."
|
|
::= { upsDiagPMEnclDoorFltrEntry 4 }
|
|
|
|
upsDiagPMEnclDoorFltrEstmtdLifetimeRmngPct OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Displays the percentage of the total lifetime remaining for the module
|
|
door filter before it should be replaced."
|
|
::= { upsDiagPMEnclDoorFltrEntry 5 }
|
|
|
|
|
|
|
|
-- the upsDiagnosticBatteries group
|
|
|
|
upsDiagBatteryTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of batteries supported by the UPS."
|
|
::= { upsDiagnosticBatteries 1 }
|
|
|
|
upsDiagBatteryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagBatteryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual batteries. The number of
|
|
entries is contained in the upsDiagBattTableSize OID."
|
|
::= { upsDiagnosticBatteries 2 }
|
|
|
|
upsDiagBatteryEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagBatteryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of a battery."
|
|
INDEX { upsDiagBatteryIndex}
|
|
::= { upsDiagBatteryTable 1 }
|
|
|
|
UpsDiagBatteryEntry ::=
|
|
SEQUENCE {
|
|
upsDiagBatteryFrameIndex INTEGER,
|
|
upsDiagBatteryIndex INTEGER,
|
|
upsDiagBatteryStatus INTEGER,
|
|
upsDiagBatterySerialNumber DisplayString,
|
|
upsDiagBatteryFirmwareRev DisplayString,
|
|
upsDiagBatteryManufactureDate DisplayString,
|
|
upsDiagBatteryType DisplayString,
|
|
upsDiagBatteryFramePresent INTEGER,
|
|
upsDiagBatteryFrameTemperature INTEGER
|
|
}
|
|
|
|
upsDiagBatteryFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the battery frame entry.
|
|
Frame 0 indicates the Main frame. Extended Run (XR) frames
|
|
start from index 1."
|
|
::= { upsDiagBatteryEntry 1 }
|
|
|
|
upsDiagBatteryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the battery entry."
|
|
::= { upsDiagBatteryEntry 2 }
|
|
|
|
upsDiagBatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
ok (3),
|
|
failed (4),
|
|
highTemperature (5),
|
|
replaceImmediately (6),
|
|
lowCapacity (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the battery.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
ok(3) indicates the battery status is OK.
|
|
failed(4) indicates the battery status is failed.
|
|
highTemperature(5) indicates the battery has a high temperature condition.
|
|
replaceImmediately(6) indicates the battery must be replaced immediately.
|
|
lowCapacity(7) indicates the battery has a low capacity."
|
|
::= { upsDiagBatteryEntry 3 }
|
|
|
|
upsDiagBatterySerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the battery."
|
|
::= { upsDiagBatteryEntry 4 }
|
|
|
|
upsDiagBatteryFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the battery."
|
|
::= { upsDiagBatteryEntry 5 }
|
|
|
|
upsDiagBatteryManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The manufacture date of the battery."
|
|
::= { upsDiagBatteryEntry 6 }
|
|
|
|
upsDiagBatteryType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery type or rating for the battery."
|
|
::= { upsDiagBatteryEntry 7 }
|
|
|
|
|
|
upsDiagBatteryFramePresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent(0),
|
|
present(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery frame/cabinet status.
|
|
0 indicates frame/cabinet is not present.
|
|
1 indicates frame/cabinet is present."
|
|
::= { upsDiagBatteryEntry 8 }
|
|
|
|
upsDiagBatteryFrameTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery frame/cabinet temperature in tenths of degrees celsius.
|
|
If the frame/cabinet is not present, this variable is set to (-1)."
|
|
::= { upsDiagBatteryEntry 9 }
|
|
|
|
|
|
-- the upsDiagnosticSubsystem group
|
|
|
|
upsDiagSubSysFrameTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames attached to the UPS including the Main frame."
|
|
::= { upsDiagnosticSubsystem 1 }
|
|
|
|
upsDiagSubSysFrameTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysFrameEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual XR Frames."
|
|
::= { upsDiagnosticSubsystem 2 }
|
|
|
|
upsDiagSubSysFrameEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysFrameEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of an XR Frame."
|
|
INDEX { upsDiagSubSysFrameIndex}
|
|
::= { upsDiagSubSysFrameTable 1 }
|
|
|
|
UpsDiagSubSysFrameEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysFrameIndex INTEGER,
|
|
upsDiagSubSysFrameType INTEGER,
|
|
upsDiagSubSysFrameFirmwareRev DisplayString,
|
|
upsDiagSubSysFrameHardwareRev DisplayString,
|
|
upsDiagSubSysFrameSerialNum DisplayString,
|
|
upsDiagSubSysFrameManufactureDate DisplayString
|
|
}
|
|
|
|
upsDiagSubSysFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysFrameEntry 1 }
|
|
|
|
upsDiagSubSysFrameType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
frameTypeMain (3),
|
|
frameTypeXR (4),
|
|
frameTypeLXR (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of Frame.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
frameTypeMain(3) indicates the frame type is the Main Frame.
|
|
frameTypeXR(4) indicates the frame type is an XR Frame.
|
|
frameTypeLXR(5) indicates the frame type is an LXR Frame."
|
|
::= { upsDiagSubSysFrameEntry 2 }
|
|
|
|
upsDiagSubSysFrameFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the frame."
|
|
::= { upsDiagSubSysFrameEntry 3 }
|
|
|
|
upsDiagSubSysFrameHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the frame."
|
|
::= { upsDiagSubSysFrameEntry 4 }
|
|
|
|
upsDiagSubSysFrameSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the frame."
|
|
::= { upsDiagSubSysFrameEntry 5 }
|
|
|
|
upsDiagSubSysFrameManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The manufacture date of the frame."
|
|
::= { upsDiagSubSysFrameEntry 6 }
|
|
|
|
upsDiagSubSysIntBypSwitchTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Internal Bypass switches attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 3 }
|
|
|
|
upsDiagSubSysIntBypSwitchTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysIntBypSwitchEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of the Internal Bypass Switch."
|
|
::= { upsDiagnosticSubsystem 4 }
|
|
|
|
upsDiagSubSysIntBypSwitchEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysIntBypSwitchEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of the Internal Bypass Switch."
|
|
INDEX { upsDiagSubSysIntBypSwitchIndex}
|
|
::= { upsDiagSubSysIntBypSwitchTable 1 }
|
|
|
|
UpsDiagSubSysIntBypSwitchEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysIntBypSwitchFrameIndex INTEGER,
|
|
upsDiagSubSysIntBypSwitchIndex INTEGER,
|
|
upsDiagSubSysIntBypSwitchStatus INTEGER,
|
|
upsDiagSubSysIntBypSwitchFirmwareRev DisplayString,
|
|
upsDiagSubSysIntBypSwitchHardwareRev DisplayString,
|
|
upsDiagSubSysIntBypSwitchSerialNum DisplayString,
|
|
upsDiagSubSysIntBypSwitchManufactureDate DisplayString
|
|
}
|
|
|
|
upsDiagSubSysIntBypSwitchFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysIntBypSwitchEntry 1 }
|
|
|
|
upsDiagSubSysIntBypSwitchIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Internal Bypass Switch index entry."
|
|
::= { upsDiagSubSysIntBypSwitchEntry 2 }
|
|
|
|
upsDiagSubSysIntBypSwitchStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Internal Bypass Switch status.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagSubSysIntBypSwitchEntry 3 }
|
|
|
|
upsDiagSubSysIntBypSwitchFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the Internal Bypass Switch."
|
|
::= { upsDiagSubSysIntBypSwitchEntry 4 }
|
|
|
|
upsDiagSubSysIntBypSwitchHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Internal Bypass Switch."
|
|
::= { upsDiagSubSysIntBypSwitchEntry 5 }
|
|
|
|
upsDiagSubSysIntBypSwitchSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the Internal Bypass Switch."
|
|
::= { upsDiagSubSysIntBypSwitchEntry 6 }
|
|
|
|
upsDiagSubSysIntBypSwitchManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The manufacture date of the Internal Bypass Switch."
|
|
::= { upsDiagSubSysIntBypSwitchEntry 7 }
|
|
|
|
upsDiagSubSysBattMonitorTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Battery Monitor Boards attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 5 }
|
|
|
|
upsDiagSubSysBattMonitorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysBattMonitorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of the Battery Monitor Board."
|
|
::= { upsDiagnosticSubsystem 6 }
|
|
|
|
upsDiagSubSysBattMonitorEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysBattMonitorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of the Battery Monitor Board."
|
|
INDEX { upsDiagSubSysBattMonitorIndex}
|
|
::= { upsDiagSubSysBattMonitorTable 1 }
|
|
|
|
UpsDiagSubSysBattMonitorEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysBattMonitorFrameIndex INTEGER,
|
|
upsDiagSubSysBattMonitorIndex INTEGER,
|
|
upsDiagSubSysBattMonitorStatus INTEGER,
|
|
upsDiagSubSysBattMonitorFirmwareRev DisplayString,
|
|
upsDiagSubSysBattMonitorHardwareRev DisplayString,
|
|
upsDiagSubSysBattMonitorSerialNum DisplayString,
|
|
upsDiagSubSysBattMonitorManufactureDate DisplayString
|
|
}
|
|
|
|
upsDiagSubSysBattMonitorFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysBattMonitorEntry 1 }
|
|
|
|
upsDiagSubSysBattMonitorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the Battery Monitor Board."
|
|
::= { upsDiagSubSysBattMonitorEntry 2 }
|
|
|
|
upsDiagSubSysBattMonitorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Battery Monitor Board.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagSubSysBattMonitorEntry 3 }
|
|
|
|
upsDiagSubSysBattMonitorFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the Battery Monitor Board."
|
|
::= { upsDiagSubSysBattMonitorEntry 4 }
|
|
|
|
upsDiagSubSysBattMonitorHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Battery Monitor Board."
|
|
::= { upsDiagSubSysBattMonitorEntry 5 }
|
|
|
|
upsDiagSubSysBattMonitorSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the Battery Monitor Board."
|
|
::= { upsDiagSubSysBattMonitorEntry 6 }
|
|
|
|
upsDiagSubSysBattMonitorManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of the manufacture for the Battery Monitor Board."
|
|
::= { upsDiagSubSysBattMonitorEntry 7 }
|
|
|
|
upsDiagSubSysExternalSwitchGearTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of External Switch Gears attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 7 }
|
|
|
|
upsDiagSubSysExternalSwitchGearTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysExternalSwitchGearEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of the individual External Switch Gear."
|
|
::= { upsDiagnosticSubsystem 8 }
|
|
|
|
upsDiagSubSysExternalSwitchGearEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysExternalSwitchGearEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of an individual External Switch Gear."
|
|
INDEX { upsDiagSubSysExternalSwitchGearIndex}
|
|
::= { upsDiagSubSysExternalSwitchGearTable 1 }
|
|
|
|
UpsDiagSubSysExternalSwitchGearEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysExternalSwitchGearFrameIndex INTEGER,
|
|
upsDiagSubSysExternalSwitchGearIndex INTEGER,
|
|
upsDiagSubSysExternalSwitchGearStatus INTEGER,
|
|
upsDiagSubSysExternalSwitchGearFirmwareRev DisplayString,
|
|
upsDiagSubSysExternalSwitchGearHardwareRev DisplayString,
|
|
upsDiagSubSysExternalSwitchGearSerialNum DisplayString,
|
|
upsDiagSubSysExternalSwitchGearManufactureDate DisplayString
|
|
}
|
|
|
|
upsDiagSubSysExternalSwitchGearFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysExternalSwitchGearEntry 1 }
|
|
|
|
upsDiagSubSysExternalSwitchGearIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the External Switch Gear."
|
|
::= { upsDiagSubSysExternalSwitchGearEntry 2 }
|
|
|
|
upsDiagSubSysExternalSwitchGearStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the External Switch Gear.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagSubSysExternalSwitchGearEntry 3 }
|
|
|
|
upsDiagSubSysExternalSwitchGearFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the External Switch Gear monitor card."
|
|
::= { upsDiagSubSysExternalSwitchGearEntry 4 }
|
|
|
|
upsDiagSubSysExternalSwitchGearHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the External Switch Gear monitor card."
|
|
::= { upsDiagSubSysExternalSwitchGearEntry 5 }
|
|
|
|
upsDiagSubSysExternalSwitchGearSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the External Switch Gear monitor card."
|
|
::= { upsDiagSubSysExternalSwitchGearEntry 6 }
|
|
|
|
upsDiagSubSysExternalSwitchGearManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of the manufacture for the External Switch Gear monitor card."
|
|
::= { upsDiagSubSysExternalSwitchGearEntry 7 }
|
|
|
|
upsDiagSubSysDisplayInterfaceCardTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Display Interface Cards attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 9 }
|
|
|
|
upsDiagSubSysDisplayInterfaceCardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysDisplayInterfaceCardEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual Display Interface Cards."
|
|
::= { upsDiagnosticSubsystem 10 }
|
|
|
|
upsDiagSubSysDisplayInterfaceCardEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysDisplayInterfaceCardEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of a Display Interface Card."
|
|
INDEX { upsDiagSubSysDisplayInterfaceCardIndex}
|
|
::= { upsDiagSubSysDisplayInterfaceCardTable 1 }
|
|
|
|
UpsDiagSubSysDisplayInterfaceCardEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysDisplayInterfaceCardFrameIndex INTEGER,
|
|
upsDiagSubSysDisplayInterfaceCardIndex INTEGER,
|
|
upsDiagSubSysDisplayInterfaceCardStatus INTEGER
|
|
}
|
|
|
|
upsDiagSubSysDisplayInterfaceCardFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysDisplayInterfaceCardEntry 1 }
|
|
|
|
upsDiagSubSysDisplayInterfaceCardIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the Display Interface Card."
|
|
::= { upsDiagSubSysDisplayInterfaceCardEntry 2 }
|
|
|
|
upsDiagSubSysDisplayInterfaceCardStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Display Interface Card.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagSubSysDisplayInterfaceCardEntry 3 }
|
|
|
|
upsDiagSubSysDCCircuitBreakerTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC Circuit Breakers attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 11 }
|
|
|
|
upsDiagSubSysDCCircuitBreakerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysDCCircuitBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual DC Circuit Breakers."
|
|
::= { upsDiagnosticSubsystem 12 }
|
|
|
|
upsDiagSubSysDCCircuitBreakerEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysDCCircuitBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of a DC Circuit Breaker."
|
|
INDEX { upsDiagSubSysDCCircuitBreakerIndex}
|
|
::= { upsDiagSubSysDCCircuitBreakerTable 1 }
|
|
|
|
UpsDiagSubSysDCCircuitBreakerEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysDCCircuitBreakerFrameIndex INTEGER,
|
|
upsDiagSubSysDCCircuitBreakerIndex INTEGER,
|
|
upsDiagSubSysDCCircuitBreakerStatus INTEGER
|
|
}
|
|
|
|
upsDiagSubSysDCCircuitBreakerFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysDCCircuitBreakerEntry 1 }
|
|
|
|
upsDiagSubSysDCCircuitBreakerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the DC Circuit Breaker."
|
|
::= { upsDiagSubSysDCCircuitBreakerEntry 2 }
|
|
|
|
upsDiagSubSysDCCircuitBreakerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
opened (3),
|
|
closed (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the DC Circuit Breaker.
|
|
unknown(1) indicates the circuit breaker status is unknown.
|
|
notInstalled(2) indicates the circuit breaker is not installed.
|
|
opened(3) indicates the circuit breaker is opened.
|
|
closed(4) indicates the circuit breaker is closed."
|
|
::= { upsDiagSubSysDCCircuitBreakerEntry 3 }
|
|
|
|
upsDiagSubSysSystemPowerSupplyTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of System Power Supplies attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 13 }
|
|
|
|
upsDiagSubSysSystemPowerSupplyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysSystemPowerSupplyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual System Power Supplies."
|
|
::= { upsDiagnosticSubsystem 14 }
|
|
|
|
upsDiagSubSysSystemPowerSupplyEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysSystemPowerSupplyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of a System Power Supply."
|
|
INDEX { upsDiagSubSysSystemPowerSupplyIndex}
|
|
::= { upsDiagSubSysSystemPowerSupplyTable 1 }
|
|
|
|
UpsDiagSubSysSystemPowerSupplyEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysSystemPowerSupplyFrameIndex INTEGER,
|
|
upsDiagSubSysSystemPowerSupplyIndex INTEGER,
|
|
upsDiagSubSysSystemPowerSupplyStatus INTEGER,
|
|
upsDiagSubSysSystemPowerSupplyFirmwareRev DisplayString,
|
|
upsDiagSubSysSystemPowerSupplyHardwareRev DisplayString,
|
|
upsDiagSubSysSystemPowerSupplySerialNum DisplayString,
|
|
upsDiagSubSysSystemPowerSupplyManufactureDate DisplayString
|
|
}
|
|
|
|
upsDiagSubSysSystemPowerSupplyFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysSystemPowerSupplyEntry 1 }
|
|
|
|
upsDiagSubSysSystemPowerSupplyIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of a System Power Supply."
|
|
::= { upsDiagSubSysSystemPowerSupplyEntry 2 }
|
|
|
|
upsDiagSubSysSystemPowerSupplyStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the System Power Supply.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagSubSysSystemPowerSupplyEntry 3 }
|
|
|
|
upsDiagSubSysSystemPowerSupplyFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the System Power Supply monitor card."
|
|
::= { upsDiagSubSysSystemPowerSupplyEntry 4 }
|
|
|
|
upsDiagSubSysSystemPowerSupplyHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the System Power Supply monitor card."
|
|
::= { upsDiagSubSysSystemPowerSupplyEntry 5 }
|
|
|
|
upsDiagSubSysSystemPowerSupplySerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the System Power Supply monitor card."
|
|
::= { upsDiagSubSysSystemPowerSupplyEntry 6 }
|
|
|
|
upsDiagSubSysSystemPowerSupplyManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of the manufacture for the System Power Supply monitor card."
|
|
::= { upsDiagSubSysSystemPowerSupplyEntry 7 }
|
|
|
|
upsDiagSubSysXRCommunicationCardTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of XR Communication Cards attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 15 }
|
|
|
|
upsDiagSubSysXRCommunicationCardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysXRCommunicationCardEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual XR Communication Cards."
|
|
::= { upsDiagnosticSubsystem 16 }
|
|
|
|
upsDiagSubSysXRCommunicationCardEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysXRCommunicationCardEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of an XR Communication Card."
|
|
INDEX { upsDiagSubSysXRCommunicationCardIndex}
|
|
::= { upsDiagSubSysXRCommunicationCardTable 1 }
|
|
|
|
UpsDiagSubSysXRCommunicationCardEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysXRCommunicationCardFrameIndex INTEGER,
|
|
upsDiagSubSysXRCommunicationCardIndex INTEGER,
|
|
upsDiagSubSysXRCommunicationCardStatus INTEGER,
|
|
upsDiagSubSysXRCommunicationCardFirmwareRev DisplayString,
|
|
upsDiagSubSysXRCommunicationCardSerialNum DisplayString
|
|
|
|
}
|
|
|
|
upsDiagSubSysXRCommunicationCardFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysXRCommunicationCardEntry 1 }
|
|
|
|
upsDiagSubSysXRCommunicationCardIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of an XR Communication Card."
|
|
::= { upsDiagSubSysXRCommunicationCardEntry 2 }
|
|
|
|
upsDiagSubSysXRCommunicationCardStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the XR Communication Card.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagSubSysXRCommunicationCardEntry 3 }
|
|
|
|
upsDiagSubSysXRCommunicationCardFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the XR Communication card."
|
|
::= { upsDiagSubSysXRCommunicationCardEntry 4 }
|
|
|
|
upsDiagSubSysXRCommunicationCardSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the XR Communication card."
|
|
::= { upsDiagSubSysXRCommunicationCardEntry 5 }
|
|
|
|
upsDiagSubSysExternalPowerFrameBoardTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of External Power Frame Boards attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 17 }
|
|
|
|
upsDiagSubSysExternalPowerFrameBoardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysExternalPowerFrameBoardEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual External Power Frame Boards."
|
|
::= { upsDiagnosticSubsystem 18 }
|
|
|
|
upsDiagSubSysExternalPowerFrameBoardEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysExternalPowerFrameBoardEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of an External Power Frame Board."
|
|
INDEX { upsDiagSubSysExternalPowerFrameBoardIndex}
|
|
::= { upsDiagSubSysExternalPowerFrameBoardTable 1 }
|
|
|
|
UpsDiagSubSysExternalPowerFrameBoardEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysExternalPowerFrameBoardFrameIndex INTEGER,
|
|
upsDiagSubSysExternalPowerFrameBoardIndex INTEGER,
|
|
upsDiagSubSysExternalPowerFrameBoardStatus INTEGER
|
|
}
|
|
|
|
upsDiagSubSysExternalPowerFrameBoardFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysExternalPowerFrameBoardEntry 1 }
|
|
|
|
upsDiagSubSysExternalPowerFrameBoardIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of an External Power Frame Board."
|
|
::= { upsDiagSubSysExternalPowerFrameBoardEntry 2 }
|
|
|
|
upsDiagSubSysExternalPowerFrameBoardStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the External Power Frame Board.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagSubSysExternalPowerFrameBoardEntry 3 }
|
|
|
|
upsDiagSubSysChargerTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Chargers attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 19 }
|
|
|
|
upsDiagSubSysChargerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysChargerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual chargers."
|
|
::= { upsDiagnosticSubsystem 20 }
|
|
|
|
upsDiagSubSysChargerEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysChargerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of a charger."
|
|
INDEX { upsDiagSubSysChargerIndex}
|
|
::= { upsDiagSubSysChargerTable 1 }
|
|
|
|
UpsDiagSubSysChargerEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysChargerFrameIndex INTEGER,
|
|
upsDiagSubSysChargerIndex INTEGER,
|
|
upsDiagSubSysChargerStatus INTEGER
|
|
}
|
|
|
|
upsDiagSubSysChargerFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysChargerEntry 1 }
|
|
|
|
upsDiagSubSysChargerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of a charger."
|
|
::= { upsDiagSubSysChargerEntry 2 }
|
|
|
|
upsDiagSubSysChargerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Charger.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagSubSysChargerEntry 3 }
|
|
|
|
upsDiagSubSysInverterTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Inverters attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 21 }
|
|
|
|
upsDiagSubSysInverterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysInverterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual Inverters."
|
|
::= { upsDiagnosticSubsystem 22 }
|
|
|
|
upsDiagSubSysInverterEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysInverterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of an Inverter."
|
|
INDEX { upsDiagSubSysInverterIndex}
|
|
::= { upsDiagSubSysInverterTable 1 }
|
|
|
|
UpsDiagSubSysInverterEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysInverterFrameIndex INTEGER,
|
|
upsDiagSubSysInverterIndex INTEGER,
|
|
upsDiagSubSysInverterStatus INTEGER,
|
|
upsDiagSubSysInverterFirmwareRev DisplayString,
|
|
upsDiagSubSysInverterHardwareRev DisplayString,
|
|
upsDiagSubSysInverterSerialNum DisplayString,
|
|
upsDiagSubSysInverterManufactureDate DisplayString
|
|
}
|
|
|
|
upsDiagSubSysInverterFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysInverterEntry 1 }
|
|
|
|
upsDiagSubSysInverterIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of an Inverter."
|
|
::= { upsDiagSubSysInverterEntry 2 }
|
|
|
|
upsDiagSubSysInverterStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Inverter.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagSubSysInverterEntry 3 }
|
|
|
|
upsDiagSubSysInverterFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the Inverter monitor."
|
|
::= { upsDiagSubSysInverterEntry 4 }
|
|
|
|
upsDiagSubSysInverterHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Inverter monitor."
|
|
::= { upsDiagSubSysInverterEntry 5 }
|
|
|
|
upsDiagSubSysInverterSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the Inverter monitor."
|
|
::= { upsDiagSubSysInverterEntry 6 }
|
|
|
|
upsDiagSubSysInverterManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of manufacture for the Inverter monitor."
|
|
::= { upsDiagSubSysInverterEntry 7 }
|
|
|
|
upsDiagSubSysPowerFactorCorrectionTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Power Factor Correction devices attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 23 }
|
|
|
|
upsDiagSubSysPowerFactorCorrectionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysPowerFactorCorrectionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of individual PowerFactorCorrections."
|
|
::= { upsDiagnosticSubsystem 24 }
|
|
|
|
upsDiagSubSysPowerFactorCorrectionEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysPowerFactorCorrectionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of a Power Factor Correction."
|
|
INDEX { upsDiagSubSysPowerFactorCorrectionIndex}
|
|
::= { upsDiagSubSysPowerFactorCorrectionTable 1 }
|
|
|
|
UpsDiagSubSysPowerFactorCorrectionEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysPowerFactorCorrectionFrameIndex INTEGER,
|
|
upsDiagSubSysPowerFactorCorrectionIndex INTEGER,
|
|
upsDiagSubSysPowerFactorCorrectionStatus INTEGER,
|
|
upsDiagSubSysPowerFactorCorrectionFirmwareRev DisplayString,
|
|
upsDiagSubSysPowerFactorCorrectionHardwareRev DisplayString,
|
|
upsDiagSubSysPowerFactorCorrectionSerialNum DisplayString,
|
|
upsDiagSubSysPowerFactorCorrectionManufactureDate DisplayString
|
|
}
|
|
|
|
upsDiagSubSysPowerFactorCorrectionFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frame index entry."
|
|
::= { upsDiagSubSysPowerFactorCorrectionEntry 1 }
|
|
|
|
upsDiagSubSysPowerFactorCorrectionIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of a Power Factor Correction."
|
|
::= { upsDiagSubSysPowerFactorCorrectionEntry 2 }
|
|
|
|
upsDiagSubSysPowerFactorCorrectionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
offOk (3),
|
|
onOk (4),
|
|
offFail (5),
|
|
onFail (6),
|
|
lostComm (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Power Factor Correction.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
offOk(3) indicates the device status is off and OK.
|
|
onOk(4) indicates the device status is on and OK.
|
|
offFail(5) indicates the device status is off and failed.
|
|
onFail(6) indicates the device status is on and failed.
|
|
lostComm(7) indicates the device has lost communication."
|
|
::= { upsDiagSubSysPowerFactorCorrectionEntry 3 }
|
|
|
|
upsDiagSubSysPowerFactorCorrectionFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the Power Factor Correction monitor."
|
|
::= { upsDiagSubSysPowerFactorCorrectionEntry 4 }
|
|
|
|
upsDiagSubSysPowerFactorCorrectionHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Power Factor Correction monitor."
|
|
::= { upsDiagSubSysPowerFactorCorrectionEntry 5 }
|
|
|
|
upsDiagSubSysPowerFactorCorrectionSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the Power Factor Correction monitor."
|
|
::= { upsDiagSubSysPowerFactorCorrectionEntry 6 }
|
|
|
|
upsDiagSubSysPowerFactorCorrectionManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of the manufacture for the Power Factor Correction monitor."
|
|
::= { upsDiagSubSysPowerFactorCorrectionEntry 7 }
|
|
|
|
upsDiagSubSysNetworkComCardTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Network Communication Cards attached to the UPS."
|
|
::= { upsDiagnosticSubsystem 25 }
|
|
|
|
upsDiagSubSysNetworkComCardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubSysNetworkComCardEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting diagnostics information of an individual Network Communication Card."
|
|
::= { upsDiagnosticSubsystem 26 }
|
|
|
|
upsDiagSubSysNetworkComCardEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubSysNetworkComCardEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of a Network Communication Card."
|
|
INDEX { upsDiagSubSysNetworkComCardIndex}
|
|
::= { upsDiagSubSysNetworkComCardTable 1 }
|
|
|
|
UpsDiagSubSysNetworkComCardEntry ::=
|
|
SEQUENCE {
|
|
upsDiagSubSysNetworkComCardIndex INTEGER,
|
|
upsDiagSubSysNetworkComCardModelNumber DisplayString,
|
|
upsDiagSubSysNetworkComCardSerialNumber DisplayString,
|
|
upsDiagSubSysNetworkComCardDateOfManufacture DisplayString,
|
|
upsDiagSubSysNetworkComCardHardwareRev DisplayString,
|
|
upsDiagSubSysNetworkComCardFirmwareAppRev DisplayString,
|
|
upsDiagSubSysNetworkComCardFirmwareAppOSRev DisplayString
|
|
}
|
|
|
|
upsDiagSubSysNetworkComCardIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS network and display interface communication card index entry."
|
|
::= { upsDiagSubSysNetworkComCardEntry 1 }
|
|
|
|
upsDiagSubSysNetworkComCardModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the model number of the UPS network and display interface communication card.
|
|
This value is set at the factory."
|
|
::= { upsDiagSubSysNetworkComCardEntry 2 }
|
|
|
|
upsDiagSubSysNetworkComCardSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the serial number of the UPS network and display interface communication card.
|
|
This value is set at the factory."
|
|
::= { upsDiagSubSysNetworkComCardEntry 3 }
|
|
|
|
upsDiagSubSysNetworkComCardDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the UPS network and display interface communication card was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory."
|
|
::= { upsDiagSubSysNetworkComCardEntry 4 }
|
|
|
|
upsDiagSubSysNetworkComCardHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the UPS network and display interface communication card.
|
|
This value is set at the factory."
|
|
::= { upsDiagSubSysNetworkComCardEntry 5 }
|
|
|
|
upsDiagSubSysNetworkComCardFirmwareAppRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ID string identifying the application firmware revision of the
|
|
UPS network and display interface communication card."
|
|
::= { upsDiagSubSysNetworkComCardEntry 6 }
|
|
|
|
upsDiagSubSysNetworkComCardFirmwareAppOSRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ID string identifying the application operating system firmware revision of the
|
|
UPS network and display interface communication card."
|
|
::= { upsDiagSubSysNetworkComCardEntry 7 }
|
|
|
|
-- the upsDiagnosticExternalDevices group
|
|
|
|
upsDiagSwitchGearStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
ok (3),
|
|
fail (4),
|
|
lostComm (5),
|
|
overtemp (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Switch Gear.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
ok(3) indicates the device status is OK.
|
|
fail(4) indicates the device status has failed.
|
|
lostComm(5) indicates the device has lost communication.
|
|
overtemp(6) indicates the device has an over temperature condition."
|
|
::= { upsDiagSwitchGear 1 }
|
|
|
|
upsDiagSwitchGearInputSwitchStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
opened (3),
|
|
closed (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Switch Gear Input Switch.
|
|
unknown(1) indicates the switch status is unknown.
|
|
notInstalled(2) indicates the switch is not installed.
|
|
opened(3) indicates the switch is opened.
|
|
closed(4) indicates the switch is closed."
|
|
::= { upsDiagSwitchGear 2 }
|
|
|
|
upsDiagSwitchGearOutputSwitchStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
opened (3),
|
|
closed (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Switch Gear Output Switch.
|
|
unknown(1) indicates the switch status is unknown.
|
|
notInstalled(2) indicates the switch is not installed.
|
|
opened(3) indicates the switch is opened.
|
|
closed(4) indicates the switch is closed."
|
|
::= { upsDiagSwitchGear 3 }
|
|
|
|
upsDiagSwitchGearBypassSwitchStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
opened (3),
|
|
closed (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Switch Gear Bypass Switch.
|
|
unknown(1) indicates the switch status is unknown.
|
|
notInstalled(2) indicates the switch is not installed.
|
|
opened(3) indicates the switch is opened.
|
|
closed(4) indicates the switch is closed."
|
|
::= { upsDiagSwitchGear 4 }
|
|
|
|
upsDiagSwitchGearBypassInputSwitchStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
opened (3),
|
|
closed (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Switch Gear Bypass Input Switch.
|
|
unknown(1) indicates the switch status is unknown.
|
|
notInstalled(2) indicates the switch is not installed.
|
|
opened(3) indicates the switch is opened.
|
|
closed(4) indicates the switch is closed."
|
|
::= { upsDiagSwitchGear 5 }
|
|
|
|
upsDiagSwitchGearBreakerTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of switchgear breakers attached to the UPS."
|
|
::= { upsDiagSwitchGear 6 }
|
|
|
|
upsDiagSwitchGearBreakerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSwitchGearBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switchgear breaker table."
|
|
::= { upsDiagSwitchGear 7 }
|
|
|
|
upsDiagSwitchGearBreakerEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSwitchGearBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of switchgear breakers."
|
|
INDEX { switchgearBreakerIndex }
|
|
::= { upsDiagSwitchGearBreakerTable 1 }
|
|
|
|
UpsDiagSwitchGearBreakerEntry ::=
|
|
SEQUENCE {
|
|
switchgearBreakerIndex
|
|
INTEGER,
|
|
switchgearBreakerPresent
|
|
INTEGER,
|
|
switchgearBreakerName
|
|
DisplayString,
|
|
switchgearBreakerType
|
|
INTEGER,
|
|
switchgearBreakerStatus
|
|
INTEGER
|
|
}
|
|
|
|
switchgearBreakerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the switchgear breaker."
|
|
::= { upsDiagSwitchGearBreakerEntry 1 }
|
|
|
|
switchgearBreakerPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent(1),
|
|
present(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if the switchgear breaker is present.
|
|
notPresent(1) indicates that the breaker is not present.
|
|
present(2) indicates that the breaker is present."
|
|
::= { upsDiagSwitchGearBreakerEntry 2 }
|
|
|
|
switchgearBreakerName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the switchgear breaker."
|
|
::= { upsDiagSwitchGearBreakerEntry 3 }
|
|
|
|
|
|
switchgearBreakerType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
unitInputBreaker(2),
|
|
staticSwitchInputBreaker(3),
|
|
maintenanceBypassBreaker(4),
|
|
unitOutputBreaker(5),
|
|
systemIsolationBreaker(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the switchgear breaker types available in the UPS system.
|
|
If the UPS is unable to find any attached breakers, this variable
|
|
is set to unknown(1)."
|
|
::= { upsDiagSwitchGearBreakerEntry 4 }
|
|
|
|
switchgearBreakerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
opened(2),
|
|
closed(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of switchgear breaker.
|
|
unknown(1) indicates the breaker status is unknown.
|
|
opened (2) indicates the breaker is opened.
|
|
closed (3) indicates the breaker is closed."
|
|
::= { upsDiagSwitchGearBreakerEntry 5 }
|
|
|
|
|
|
|
|
upsDiagSubFeedBreakerTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of subfeed breakers attached to the UPS."
|
|
::= { upsDiagSwitchGear 8 }
|
|
|
|
upsDiagSubFeedBreakerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDiagSubFeedBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subfeed breaker table."
|
|
::= { upsDiagSwitchGear 9 }
|
|
|
|
upsDiagSubFeedBreakerEntry OBJECT-TYPE
|
|
SYNTAX UpsDiagSubFeedBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of subfeed breakers."
|
|
INDEX { subfeedBreakerIndex }
|
|
::= { upsDiagSubFeedBreakerTable 1 }
|
|
|
|
UpsDiagSubFeedBreakerEntry ::=
|
|
SEQUENCE {
|
|
subfeedBreakerIndex
|
|
INTEGER,
|
|
subfeedBreakerPresent
|
|
INTEGER,
|
|
subfeedBreakerRating
|
|
INTEGER,
|
|
subfeedBreakerUpperAcceptPowerWarning
|
|
INTEGER,
|
|
subfeedBreakerUpperAcceptPowerCritical
|
|
INTEGER,
|
|
subfeedBreakerStatus
|
|
INTEGER,
|
|
subfeedBreakerName
|
|
DisplayString
|
|
}
|
|
|
|
subfeedBreakerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the subfeed breakers."
|
|
::= { upsDiagSubFeedBreakerEntry 1 }
|
|
|
|
subfeedBreakerPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if the subfeed breaker is present.
|
|
notPresent (1) indicates that the breaker is not present.
|
|
present (2) indicates that the breaker is present."
|
|
::= { upsDiagSubFeedBreakerEntry 2 }
|
|
|
|
subfeedBreakerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current rating of the installed subfeed breaker."
|
|
::= { upsDiagSubFeedBreakerEntry 3 }
|
|
|
|
subfeedBreakerUpperAcceptPowerWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum acceptable load before warning is issued.
|
|
Expressed as percent of the subfeed breaker rating."
|
|
::= { upsDiagSubFeedBreakerEntry 4 }
|
|
|
|
|
|
|
|
subfeedBreakerUpperAcceptPowerCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..125)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum load before a critical alarm occurs.
|
|
Expressed as percent of the subfeed breaker rating."
|
|
::= { upsDiagSubFeedBreakerEntry 5 }
|
|
|
|
subfeedBreakerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
opened (3),
|
|
closed (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Circuit Breaker.
|
|
unknown(1) indicates the circuit breaker status is unknown.
|
|
notInstalled(2) indicates the circuit breaker is not installed.
|
|
opened(3) indicates the circuit breaker is opened.
|
|
closed(4) indicates the circuit breaker is closed."
|
|
::= { upsDiagSubFeedBreakerEntry 6 }
|
|
|
|
subfeedBreakerName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the subfeed breaker."
|
|
::= { upsDiagSubFeedBreakerEntry 7}
|
|
|
|
|
|
upsDiagSwitchGearInstallationLoadPct OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual output load expressed as a percentage of the rating of the UPS."
|
|
::= { upsDiagSwitchGear 10 }
|
|
|
|
|
|
upsDiagSubFeedPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UPSDiagSubFeedPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of subfeed phase table."
|
|
::= { upsDiagSwitchGear 11 }
|
|
|
|
upsDiagSubFeedPhaseEntry OBJECT-TYPE
|
|
SYNTAX UPSDiagSubFeedPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular phase."
|
|
INDEX { upsDiagSubFeedPhaseIndex }
|
|
::= { upsDiagSubFeedPhaseTable 1 }
|
|
|
|
UPSDiagSubFeedPhaseEntry ::= SEQUENCE {
|
|
upsDiagSubFeedBreakerIndex INTEGER,
|
|
upsDiagSubFeedPhaseIndex INTEGER,
|
|
upsDiagSubFeedPhaseCurrent INTEGER,
|
|
upsDiagSubFeedPhaseCurrentAlternate INTEGER
|
|
}
|
|
|
|
upsDiagSubFeedBreakerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The subfeed breaker index."
|
|
::= { upsDiagSubFeedPhaseEntry 1 }
|
|
|
|
upsDiagSubFeedPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The subfeed phase index."
|
|
::= { upsDiagSubFeedPhaseEntry 2 }
|
|
|
|
upsDiagSubFeedPhaseCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The subfeed phase current in Amps."
|
|
::= { upsDiagSubFeedPhaseEntry 3 }
|
|
|
|
upsDiagSubFeedPhaseCurrentAlternate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The subfeed phase current in tenths of Amps."
|
|
::= { upsDiagSubFeedPhaseEntry 4 }
|
|
|
|
|
|
upsDiagSwitchgearSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the UPS I/O Cabinet."
|
|
::= { upsDiagSwitchGear 12 }
|
|
|
|
|
|
|
|
|
|
|
|
upsDiagMCCBBoxStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
opened (3),
|
|
closed (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the MCCB Box (Molded Case Circuit Breaker Box) external device.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
opened(3) indicates the circuit is opened.
|
|
closed(4) indicates the circuit is closed."
|
|
::= { upsDiagMCCBBox 1 }
|
|
|
|
upsDiagTransformerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
ok (3),
|
|
fail (4),
|
|
lostComm (5),
|
|
overtemp (6),
|
|
opened (7),
|
|
closed (8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the External Transformer.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
ok(3) indicates the device status is OK.
|
|
fail(4) indicates the device status has failed.
|
|
lostComm(5) indicates the device has lost communication.
|
|
overtemp(6) indicates the device has an over temperature condition.
|
|
opened(7) indicates the circuit is opened.
|
|
closed(8) indicates the circuit is closed."
|
|
::= { upsDiagTransformer 1 }
|
|
|
|
|
|
upsDiagFlyWheelStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
present(2),
|
|
notPresent(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the status of flywheel connected to UPS. If the UPS
|
|
is unable to determine the state of flywheel, this variable is
|
|
set to unknown(1)."
|
|
::= { upsDiagFlyWheel 1 }
|
|
|
|
|
|
|
|
|
|
-- the upsDiagnosticComBus group
|
|
|
|
upsDiagComBusInternalMIMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
ok (3),
|
|
lostComm (4),
|
|
rxFailure (5),
|
|
txFailure (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the internal MIM communication bus.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
ok(3) indicates the device status is OK.
|
|
lostComm(4) indicates the device has lost communication.
|
|
rxFailure(5) indicates the device has a receive failure.
|
|
txFailure(6) indicates the device has a transmit failure."
|
|
::= { upsDiagnosticComBus 1 }
|
|
|
|
upsDiagComBusInternalRIMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
ok (3),
|
|
lostComm (4),
|
|
rxFailure (5),
|
|
txFailure (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the internal RIM communication bus.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
ok(3) indicates the device status is OK.
|
|
lostComm(4) indicates the device has lost communication.
|
|
rxFailure(5) indicates the device has a receive failure.
|
|
txFailure(6) indicates the device has a transmit failure."
|
|
::= { upsDiagnosticComBus 2 }
|
|
|
|
upsDiagComBusMIMtoRIMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
ok (3),
|
|
lostComm (4),
|
|
rxFailure (5),
|
|
txFailure (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the MIM to RIM communication bus.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
ok(3) indicates the device status is OK.
|
|
lostComm(4) indicates the device has lost communication.
|
|
rxFailure(5) indicates the device has a receive failure.
|
|
txFailure(6) indicates the device has a transmit failure."
|
|
::= { upsDiagnosticComBus 3 }
|
|
|
|
upsDiagComBusExternalMIMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
ok (3),
|
|
lostComm (4),
|
|
rxFailure (5),
|
|
txFailure (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the external MIM communication bus.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
ok(3) indicates the device status is OK.
|
|
lostComm(4) indicates the device has lost communication.
|
|
rxFailure(5) indicates the device has a receive failure.
|
|
txFailure(6) indicates the device has a transmit failure."
|
|
::= { upsDiagnosticComBus 4 }
|
|
|
|
upsDiagComBusExternalRIMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
ok (3),
|
|
lostComm (4),
|
|
rxFailure (5),
|
|
txFailure (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the external RIM communication bus.
|
|
unknown(1) indicates the device status is unknown.
|
|
notInstalled(2) indicates the device is not installed.
|
|
ok(3) indicates the device status is OK.
|
|
lostComm(4) indicates the device has lost communication.
|
|
rxFailure(5) indicates the device has a receive failure.
|
|
txFailure(6) indicates the device has a transmit failure."
|
|
::= { upsDiagnosticComBus 5 }
|
|
|
|
|
|
-- the upsParallelSystem group
|
|
|
|
upsParallelSysLocalAddress OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the UPS ID number in the parallel system."
|
|
::= { upsParallelSystem 1 }
|
|
|
|
upsParallelSysRemoteAddress OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the total number of UPSs in parallel."
|
|
::= { upsParallelSystem 2 }
|
|
|
|
upsParallelSysRedundancy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nplus0 (1),
|
|
nplus1 (2),
|
|
nplus2 (3),
|
|
nplus3 (4),
|
|
nplus4 (5),
|
|
nplus5 (6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The redundancy warning level for paralleled UPS
|
|
nplus0 (1) indicates that there are no redundant units.
|
|
nplus1 (2) indicates that there is one redundant unit.
|
|
nplus2 (3) indicates that there are two redundant units.
|
|
nplus3 (4) indicates that there are three redundant units.
|
|
nplus4 (5) indicates that there are four redundant unit.
|
|
nplus5 (6) indicates that there are five redundant units."
|
|
::= { upsParallelSystem 3 }
|
|
|
|
|
|
upsParallelInputMaximumCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum input RMS current of the parallel system
|
|
measured in Amperes."
|
|
::= { upsParallelSystem 4 }
|
|
|
|
upsParallelTotalOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Total Ouptut power of UPS in KW
|
|
when UPS are configured in parallel
|
|
or -1 if it's unsupported by this UPS."
|
|
::= { upsParallelSystem 5 }
|
|
|
|
upsParallelTotalOutputApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Total Ouptut Apparent power of UPS in kVA
|
|
when UPS are configured in parallel
|
|
or -1 if it's unsupported by this UPS."
|
|
::= { upsParallelSystem 6 }
|
|
|
|
-- Parallel Input Phase Table
|
|
|
|
upsParallelInputPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsParallelInputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of input table entries."
|
|
::= { upsParallelSystem 7 }
|
|
|
|
upsParallelInputPhaseEntry OBJECT-TYPE
|
|
SYNTAX UpsParallelInputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input phase."
|
|
INDEX { upsParallelInputPhaseTableIndex, upsParallelInputPhaseIndex }
|
|
::= { upsParallelInputPhaseTable 1 }
|
|
|
|
UpsParallelInputPhaseEntry ::= SEQUENCE {
|
|
upsParallelInputPhaseTableIndex INTEGER,
|
|
upsParallelInputPhaseIndex INTEGER,
|
|
upsParallelInputCurrent INTEGER,
|
|
upsParallelInputActivePower INTEGER,
|
|
upsParallelInputApparentPower INTEGER,
|
|
upsParallelInputVoltage INTEGER,
|
|
upsParallelInputMaxVoltage INTEGER,
|
|
upsParallelInputMaxCurrent INTEGER,
|
|
upsParallelInputTotalActivePower INTEGER,
|
|
upsParallelInputTotalApparentPower INTEGER
|
|
}
|
|
|
|
upsParallelInputPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The parallel unit identifier."
|
|
::= { upsParallelInputPhaseEntry 1 }
|
|
|
|
upsParallelInputPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input phase identifier."
|
|
::= { upsParallelInputPhaseEntry 2 }
|
|
|
|
|
|
upsParallelInputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input current in amperes, or -1 if it's
|
|
unsupported by this UPS."
|
|
::= { upsParallelInputPhaseEntry 3 }
|
|
|
|
upsParallelInputActivePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input power in kW, or -1 if it's
|
|
unsupported by this UPS."
|
|
::= { upsParallelInputPhaseEntry 4 }
|
|
|
|
upsParallelInputApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input apparent power in kVA, or -1 if it's
|
|
unsupported by this UPS."
|
|
::= { upsParallelInputPhaseEntry 5 }
|
|
|
|
upsParallelInputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input voltage of UPS in volts, or -1 if it's
|
|
unsupported by this UPS."
|
|
::= { upsParallelInputPhaseEntry 6 }
|
|
|
|
upsParallelInputMaxVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak input voltage in VAC measured since the last reset,
|
|
or -1 if it's unsupported by this UPS."
|
|
::= { upsParallelInputPhaseEntry 7 }
|
|
|
|
upsParallelInputMaxCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak input current in amperes measured since last reset,
|
|
or -1 if it's unsupported by this UPS."
|
|
::= { upsParallelInputPhaseEntry 8 }
|
|
|
|
upsParallelInputTotalActivePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total active input power of the parallel system in kW."
|
|
::= { upsParallelInputPhaseEntry 9 }
|
|
|
|
upsParallelInputTotalApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total apparent input power of the parallel system in kVA."
|
|
::= { upsParallelInputPhaseEntry 10 }
|
|
|
|
|
|
-- Parallel Output Phase Table
|
|
|
|
upsParallelOutputPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsParallelOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the sum of the upsPhaseNumOutputPhases."
|
|
::= { upsParallelSystem 8 }
|
|
|
|
upsParallelOutputPhaseEntry OBJECT-TYPE
|
|
SYNTAX UpsParallelOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output phase."
|
|
INDEX { upsParallelOutputPhaseTableIndex, upsParallelOutputPhaseIndex }
|
|
::= { upsParallelOutputPhaseTable 1 }
|
|
|
|
UpsParallelOutputPhaseEntry ::= SEQUENCE {
|
|
upsParallelOutputPhaseTableIndex INTEGER,
|
|
upsParallelOutputPhaseIndex INTEGER,
|
|
upsParallelOutputCurrent INTEGER,
|
|
upsParallelOutputLoad INTEGER,
|
|
upsParallelOutputPercentLoad INTEGER,
|
|
upsParallelOutputPower INTEGER
|
|
}
|
|
|
|
upsParallelOutputPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output identifier."
|
|
::= { upsParallelOutputPhaseEntry 1 }
|
|
|
|
upsParallelOutputPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output phase identifier."
|
|
::= { upsParallelOutputPhaseEntry 2 }
|
|
|
|
upsParallelOutputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output current in amperes drawn
|
|
by the load on the UPS, or -1 if it's unsupported
|
|
by this UPS."
|
|
::= { upsParallelOutputPhaseEntry 3 }
|
|
|
|
upsParallelOutputLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output load in VA, or -1 if it's unsupported
|
|
by this UPS."
|
|
::= { upsParallelOutputPhaseEntry 4 }
|
|
|
|
upsParallelOutputPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percentage of the UPS load capacity in VA at
|
|
present redundancy being used on this output phase,
|
|
or -1 if it's unsupported by this UPS."
|
|
::= { upsParallelOutputPhaseEntry 5 }
|
|
|
|
upsParallelOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output power in Watts, or -1 if it's
|
|
unsupported by this UPS."
|
|
::= { upsParallelOutputPhaseEntry 6 }
|
|
|
|
-- Parallel Output Apparent Power Table
|
|
|
|
upsParallelOutputApparentPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsParallelOutputApparentPowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of entries
|
|
is given by the value of upsOutputNumPhases."
|
|
::= { upsParallelSystem 9 }
|
|
|
|
upsParallelOutputApparentPowerEntry OBJECT-TYPE
|
|
SYNTAX UpsParallelOutputApparentPowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output."
|
|
INDEX { upsParallelOutputApparentPowerTableIndex }
|
|
::= { upsParallelOutputApparentPowerTable 1 }
|
|
|
|
UpsParallelOutputApparentPowerEntry ::= SEQUENCE {
|
|
upsParallelOutputApparentPowerTableIndex INTEGER,
|
|
upsParallelOutputApparentPower INTEGER
|
|
}
|
|
|
|
upsParallelOutputApparentPowerTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS parallel output identifier."
|
|
::= { upsParallelOutputApparentPowerEntry 1 }
|
|
|
|
upsParallelOutputApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The apparent power of each of UPS in kVA
|
|
when UPS are configured in parallel."
|
|
::= { upsParallelOutputApparentPowerEntry 2 }
|
|
|
|
|
|
upsParallelDiagSubSysBreakerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsParallelDiagSubSysBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for diagnostics of parallel Circuit Breakers."
|
|
::= { upsParallelSystem 10 }
|
|
|
|
upsParallelDiagSubSysBreakerEntry OBJECT-TYPE
|
|
SYNTAX UpsParallelDiagSubSysBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The diagnostics of Circuit Breaker."
|
|
INDEX { upsParallelDiagSubSysBreakerFrameIndex, upsParallelDiagSubSysBreakerIndex}
|
|
::= { upsParallelDiagSubSysBreakerTable 1 }
|
|
|
|
UpsParallelDiagSubSysBreakerEntry ::=
|
|
SEQUENCE {
|
|
upsParallelDiagSubSysBreakerFrameIndex INTEGER,
|
|
upsParallelDiagSubSysBreakerIndex INTEGER,
|
|
upsParallelDiagSubSysBreakerStatus INTEGER,
|
|
upsParallelDiagSubSysBreakerName DisplayString
|
|
}
|
|
|
|
upsParallelDiagSubSysBreakerFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Parallel UPS index entry."
|
|
::= { upsParallelDiagSubSysBreakerEntry 1 }
|
|
|
|
upsParallelDiagSubSysBreakerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the Circuit Breaker."
|
|
::= { upsParallelDiagSubSysBreakerEntry 2 }
|
|
|
|
upsParallelDiagSubSysBreakerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
notInstalled (2),
|
|
opened (3),
|
|
closed (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Circuit Breaker.
|
|
unknown(1) indicates the circuit breaker status is unknown.
|
|
notInstalled(2) indicates the circuit breaker is not installed.
|
|
opened(3) indicates the circuit breaker is opened.
|
|
closed(4) indicates the circuit breaker is closed."
|
|
::= { upsParallelDiagSubSysBreakerEntry 3 }
|
|
|
|
upsParallelDiagSubSysBreakerName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of Circuit Breaker."
|
|
::= { upsParallelDiagSubSysBreakerEntry 4 }
|
|
|
|
upsParallelOutputTotalPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"The percentage of the UPS total load capacity in kVA
|
|
or -1 if it's unsupported by this UPS."
|
|
::= { upsParallelSystem 11 }
|
|
-- Parallel Output Active Power Table
|
|
|
|
upsParallelOutputActivePowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsParallelOutputActivePowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of entries
|
|
is given by the value of upsParallelSysRemoteAddress."
|
|
::= { upsParallelSystem 12 }
|
|
|
|
upsParallelOutputActivePowerEntry OBJECT-TYPE
|
|
SYNTAX UpsParallelOutputActivePowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output."
|
|
INDEX { upsParallelOutputActivePowerTableIndex }
|
|
::= { upsParallelOutputActivePowerTable 1 }
|
|
|
|
UpsParallelOutputActivePowerEntry ::= SEQUENCE {
|
|
upsParallelOutputActivePowerTableIndex INTEGER,
|
|
upsParallelOutputActivePower INTEGER
|
|
}
|
|
|
|
upsParallelOutputActivePowerTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS parallel output identifier."
|
|
::= { upsParallelOutputActivePowerEntry 1 }
|
|
|
|
upsParallelOutputActivePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The active power of each UPS in kW
|
|
when UPSs are configured in parallel."
|
|
::= { upsParallelOutputActivePowerEntry 2 }
|
|
|
|
upsParallelSysSwitchGearInstallationLoadPct OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual output load expressed as a percentage of the rating of the
|
|
Parallel UPS system."
|
|
::= { upsParallelSystem 13 }
|
|
|
|
|
|
|
|
upsParallelSysRedundancyStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nplus0 (1),
|
|
nplus1 (2),
|
|
nplus2 (3),
|
|
nplus3 (4),
|
|
nplus4 (5),
|
|
nplus5 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Displays the number of backup or redundant UPSs set up on the parallel system.
|
|
nplus0 (1) no redundant units.
|
|
nplus1 (2) one redundant unit.
|
|
nplus2 (3) two redundant units.
|
|
nplus3 (4) three redundant units.
|
|
nplus4 (5) four redundant units.
|
|
nplus5 (6) five redundant units."
|
|
::= { upsParallelSystem 14 }
|
|
|
|
upsParallelSysName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ID string for the group of UPS units in the same parallel system.
|
|
Some products do not allow write operations for this OID."
|
|
::= { upsParallelSystem 15 }
|
|
|
|
|
|
|
|
|
|
-- the upsPhysicalLayout group
|
|
upsIOFrameLayoutPositionID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the position ID of UPS frame."
|
|
::= { upsPhysicalLayout 1 }
|
|
|
|
upsBottomFeedFrameLayoutPositionID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the position ID of bottom feed frame."
|
|
::= { upsPhysicalLayout 2 }
|
|
|
|
upsSwitchGearLayoutPositionID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the position ID of switchgear."
|
|
::= { upsPhysicalLayout 3 }
|
|
|
|
-- the upsBatteryFrameLayoutTable subgroup
|
|
upsBatteryFrameLayoutTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of battery frames."
|
|
::= { upsPhysicalLayout 4 }
|
|
|
|
upsBatteryFrameLayoutTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsBatteryFrameLayoutEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery frame layout position ID table."
|
|
::= { upsPhysicalLayout 5 }
|
|
|
|
upsBatteryFrameLayoutEntry OBJECT-TYPE
|
|
SYNTAX UpsBatteryFrameLayoutEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of layout position IDs of battery frames."
|
|
INDEX { batteryFrameIndex }
|
|
::= { upsBatteryFrameLayoutTable 1 }
|
|
|
|
UpsBatteryFrameLayoutEntry ::=
|
|
SEQUENCE {
|
|
batteryFrameIndex
|
|
INTEGER,
|
|
batteryFramePositionID
|
|
INTEGER
|
|
}
|
|
|
|
batteryFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the battery frame."
|
|
::= { upsBatteryFrameLayoutEntry 1 }
|
|
|
|
batteryFramePositionID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the position ID of each of the battery frames in the row."
|
|
::= { upsBatteryFrameLayoutEntry 2 }
|
|
|
|
-- the upsSideCarFrameLayoutTable subgroup
|
|
upsSideCarFrameLayoutTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of sidecar frames."
|
|
::= { upsPhysicalLayout 6 }
|
|
|
|
upsSideCarFrameLayoutTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsSideCarFrameLayoutEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sidecar frame layout position ID table."
|
|
::= { upsPhysicalLayout 7 }
|
|
|
|
upsSideCarFrameLayoutEntry OBJECT-TYPE
|
|
SYNTAX UpsSideCarFrameLayoutEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of sidecar frame layout position IDs."
|
|
INDEX { sideCarFrameIndex }
|
|
::= { upsSideCarFrameLayoutTable 1 }
|
|
|
|
UpsSideCarFrameLayoutEntry ::=
|
|
SEQUENCE {
|
|
sideCarFrameIndex
|
|
INTEGER,
|
|
sideCarFramePositionID
|
|
INTEGER
|
|
}
|
|
|
|
sideCarFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the sidecar frame."
|
|
::= { upsSideCarFrameLayoutEntry 1 }
|
|
|
|
sideCarFramePositionID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the position ID of each of the sidecar frames in the row."
|
|
::= { upsSideCarFrameLayoutEntry 2 }
|
|
|
|
-- the upsPowerFrameLayoutTable subgroup
|
|
upsPowerFrameLayoutTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of power frames."
|
|
::= { upsPhysicalLayout 8 }
|
|
|
|
upsPowerFrameLayoutTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsPowerFrameLayoutEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power frame layout position ID table."
|
|
::= { upsPhysicalLayout 9 }
|
|
|
|
upsPowerFrameLayoutEntry OBJECT-TYPE
|
|
SYNTAX UpsPowerFrameLayoutEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of power frame layout position IDs."
|
|
INDEX { powerFrameIndex }
|
|
::= { upsPowerFrameLayoutTable 1 }
|
|
|
|
UpsPowerFrameLayoutEntry ::=
|
|
SEQUENCE {
|
|
powerFrameIndex
|
|
INTEGER,
|
|
powerFramePositionID
|
|
INTEGER
|
|
}
|
|
|
|
powerFrameIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the power frame."
|
|
::= { upsPowerFrameLayoutEntry 1 }
|
|
|
|
powerFramePositionID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the position ID of each of the power frames in the row."
|
|
::= { upsPowerFrameLayoutEntry 2 }
|
|
|
|
-- the upsIntegratedATS group
|
|
|
|
upsIntegratedATSSelectedSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noSourceSelected (1),
|
|
unknown (2),
|
|
sourceA (3),
|
|
sourceB (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The source which is currently selected by the ATS to supply the UPS."
|
|
::= { upsIntegratedATS 1 }
|
|
|
|
|
|
upsIntegratedATSPreferredSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsIntegratedATSNoSourcePreference (1),
|
|
upsIntegratedATSPreferSourceA (2),
|
|
upsIntegratedATSPreferSourceB (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The preferred source of power when both sources are OK."
|
|
::= { upsIntegratedATS 2 }
|
|
|
|
upsIntegratedATSUpsReturnStaggering OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a delay factor applied to the retransfer of this UPS with integrated ATS.
|
|
When multiple UPSs are in use from a single source, each UPS can have a unique delay value,
|
|
which will reduce inrush by preventing all UPSs from transferring at the same time."
|
|
::= { upsIntegratedATS 3 }
|
|
|
|
upsIntegratedATSSourceTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input sources for this integrated ATS."
|
|
::= { upsIntegratedATS 4 }
|
|
|
|
upsIntegratedATSSourceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsIntegratedATSSourceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting status and settings for the ATS input sources.
|
|
The number of entries is contained in the upsIntegratedATSSourceTableSize OID."
|
|
::= { upsIntegratedATS 5 }
|
|
|
|
upsIntegratedATSSourceEntry OBJECT-TYPE
|
|
SYNTAX UpsIntegratedATSSourceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input source status to get."
|
|
INDEX { upsIntegratedATSSourceIndex}
|
|
::= { upsIntegratedATSSourceTable 1 }
|
|
|
|
UpsIntegratedATSSourceEntry ::=
|
|
SEQUENCE {
|
|
upsIntegratedATSSourceIndex INTEGER,
|
|
upsIntegratedATSSourceName DisplayString,
|
|
upsIntegratedATSSourceStatus INTEGER,
|
|
upsIntegratedATSLineFailDelay INTEGER,
|
|
upsIntegratedATSLineStabilityDelay INTEGER
|
|
}
|
|
|
|
upsIntegratedATSSourceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the input source entry."
|
|
::= { upsIntegratedATSSourceEntry 1 }
|
|
|
|
upsIntegratedATSSourceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the input source. This OID is provided
|
|
for informational purposes only."
|
|
::= { upsIntegratedATSSourceEntry 2 }
|
|
|
|
upsIntegratedATSSourceStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upsIntegratedATSSourceGood (1),
|
|
upsIntegratedATSSourceBad (2),
|
|
upsIntegratedATSSourceUnknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the input source status."
|
|
::= { upsIntegratedATSSourceEntry 3 }
|
|
|
|
upsIntegratedATSLineFailDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay between a selected input source becoming bad, and the ATS switching away from that source.
|
|
This delay is used to make sure that the line has truly failed before the ATS will be switched.
|
|
Specified in seconds."
|
|
::= { upsIntegratedATSSourceEntry 4 }
|
|
|
|
upsIntegratedATSLineStabilityDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay between an unselected input source becoming good, and the ATS switching to that source.
|
|
This delay is used to make sure that the line has truly returned before the ATS will be switched.
|
|
Specified in seconds."
|
|
::= { upsIntegratedATSSourceEntry 5 }
|
|
|
|
-- the upsDCOutput group
|
|
|
|
upsDCOutputStatus OBJECT IDENTIFIER ::= { upsDCOutput 1 }
|
|
|
|
upsDCOutputStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC outputs on the UPS."
|
|
::= { upsDCOutputStatus 1 }
|
|
|
|
upsDCOutputStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsDCOutputStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Provides status information on UPS DC outputs.
|
|
The number of entries is contained in the upsDCOutputStatusTableSize OID."
|
|
::= { upsDCOutputStatus 2 }
|
|
|
|
upsDCOutputStatusEntry OBJECT-TYPE
|
|
SYNTAX UpsDCOutputStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The DC output."
|
|
INDEX { upsDCOutputStatusTableIndex}
|
|
::= { upsDCOutputStatusTable 1 }
|
|
|
|
UpsDCOutputStatusEntry ::=
|
|
SEQUENCE {
|
|
upsDCOutputStatusTableIndex INTEGER,
|
|
upsDCOutputStatusVoltageNominal INTEGER,
|
|
upsDCOutputStatusCurrentRating INTEGER,
|
|
upsDCOutputStatusVoltage INTEGER,
|
|
upsDCOutputStatusCurrent INTEGER,
|
|
upsDCOutputStatusAbnormalConditions DisplayString
|
|
}
|
|
|
|
upsDCOutputStatusTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC output status entry."
|
|
::= { upsDCOutputStatusEntry 1 }
|
|
|
|
upsDCOutputStatusVoltageNominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The desired voltage for this output in tenths of VDC.
|
|
When the output is on and there are no fault conditions,
|
|
the actual voltage should be near the nominal."
|
|
::= { upsDCOutputStatusEntry 2 }
|
|
|
|
upsDCOutputStatusCurrentRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of current this output is able to supply in
|
|
tenths of amperes."
|
|
::= { upsDCOutputStatusEntry 3 }
|
|
|
|
upsDCOutputStatusVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The voltage measured on this output in tenths of VDC."
|
|
::= { upsDCOutputStatusEntry 4 }
|
|
|
|
upsDCOutputStatusCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current drawn by the load measured on this output
|
|
in tenths of amperes."
|
|
::= { upsDCOutputStatusEntry 5 }
|
|
|
|
upsDCOutputStatusAbnormalConditions OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII string containing flags representing active
|
|
output faults. If the Network Card is unable to determine
|
|
the state of the UPS, this variable is set to 'UNKNOWN'.
|
|
|
|
The flags are numbered 1 onward, read from left to
|
|
right. The flags are defined as follows starting from 1:
|
|
|
|
Flag 1: Output Overload
|
|
Flag 2: Output Short Circuit
|
|
Flag 3: Output Over Voltage
|
|
Flag 6: Backfeed Relay Fault
|
|
Flag 10: Bypass Relay Fault
|
|
Flag 19: Output Fault (over or undervoltage)
|
|
Flag 20: Bus Converter Fault
|
|
Flag 21: Sensor Fault"
|
|
::= { upsDCOutputStatusEntry 6 }
|
|
|
|
-- the serialPort2Config group
|
|
|
|
serialPort2Mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
localConsole(1),
|
|
passthrough(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Setting this variable to passthrough will enable mini's port2
|
|
behave like a UPS port. Choosing localConsole will enable the port
|
|
to be used as local console."
|
|
::= { serialPort2Config 1 }
|
|
-- the serialPort2Control group
|
|
|
|
setPulseOnTXD OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noSetPulseOnTXD(1),
|
|
setPulseOnTXD(2),
|
|
setTXDLow(3),
|
|
setTXDHigh(4)
|
|
|
|
}
|
|
ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Setting this variable to setPulseOnTXD(2)
|
|
causes adapter to generate a PULSE on TXD pin of serial port 2.
|
|
The duration in the prototype implementation will be 1 second.
|
|
|
|
Setting this value to noSetPulseOnTXD(1) has no
|
|
effect.
|
|
|
|
The value noSetPulseOnTXD(1) will always be returned
|
|
when the variable is read.
|
|
|
|
Setting this value to setTXDLow(3), or setTXDHigh(4) will keep TXD
|
|
always low or high respectively."
|
|
::= { serialPort2Control 1 }
|
|
|
|
-- the sPDUIdent group
|
|
|
|
sPDUIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the PDU. This value
|
|
is set at the factory."
|
|
::= { sPDUIdent 1 }
|
|
|
|
sPDUIdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An 8 byte ID string identifying the PDU firmware revision.
|
|
This value is set at the factory."
|
|
::= { sPDUIdent 2 }
|
|
|
|
|
|
sPDUIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the PDU was manufactured in mm/dd/yy format.
|
|
This value is set at the factory. The year 2000 will be
|
|
represented by 00."
|
|
::= { sPDUIdent 3 }
|
|
|
|
sPDUIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 10-character string identifying the model number of
|
|
the PDU internal. This value is set at the factory."
|
|
::= { sPDUIdent 4 }
|
|
|
|
sPDUIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 12-character string identifying the serial number of
|
|
the PDU internal microprocessor. This value is set at
|
|
the factory."
|
|
::= { sPDUIdent 5 }
|
|
|
|
|
|
-- the sPDUMasterControl group
|
|
|
|
sPDUMasterControlSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turnAllOnNow (1),
|
|
turnAllOnSequence (2),
|
|
turnAllOffNow (3),
|
|
rebootAllNow (4),
|
|
rebootAllSequence (5),
|
|
noCommand (6),
|
|
turnAllOffSequence (7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to turnAllOnNow (1) will turn all outlets
|
|
on immediately.
|
|
|
|
Setting this OID to turnAllOnSequence (2) will turn all outlets
|
|
on as defined by each outlet's sPDUOutletPowerOnTime OID value.
|
|
|
|
Setting this OID to turnAllOff (3) will turn all outlets
|
|
off immediately.
|
|
|
|
Setting this OID to rebootAllNow (4) will reboot all outlets
|
|
immediately.
|
|
|
|
For MasterSwitch firmware version 1.X, setting this OID to
|
|
rebootAllSequence (5) reboots all outlets, with power returned
|
|
to the outlets in the sequence defined by each outlet's
|
|
sPDUOutletPowerOnTime OID value.
|
|
|
|
For MasterSwitch firmware version 2.X, setting this OID to
|
|
rebootAllSequence (5) will cause a turnAllOffSequence to be performed.
|
|
Once all outlets are off, the MasterSwitch will then delay the
|
|
sPDUMasterConfigReboot OID time, and then perform a turnAllOnSequence.
|
|
|
|
For MasterSwitch firmware version 2.X, setting this OID to
|
|
turnAllOffSequence (7) will turn all outlets off as defined by
|
|
each outlet's sPDUOutletPowerOffTime OID value.
|
|
|
|
For MasterSwitch firmware version 1.X, setting this OID to
|
|
turnAllOffSequence (7) will have no effect.
|
|
|
|
Getting this OID will return the noCommand (6) value."
|
|
|
|
::= { sPDUMasterControl 1 }
|
|
|
|
|
|
sPDUMasterState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will cause the status of all outlets to be
|
|
returned. This OID is provided for informational purposes only.
|
|
To change the outlet state, the user should use the sPDUOutletCtl
|
|
OID in the sPDUOutletControlTable.
|
|
|
|
The format of the data returned is a character string consisting
|
|
of the word 'On' if the outlet is on or 'Off' if the outlet is
|
|
off. At least one space will delimit each outlet entry in the
|
|
string.
|
|
|
|
If the outlet states are unknown, the character string 'Unknown'
|
|
will be returned. This signifies that there is an inconsistency
|
|
in the PDU. In the rare case that this should happen, the user
|
|
is advised to shut down all equipment powered by the PDU and
|
|
then cycle the PDU's power. This will put the PDU in a consistent
|
|
state."
|
|
|
|
::= { sPDUMasterControl 2 }
|
|
|
|
sPDUMasterPending OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will cause the command pending status of all outlets to be returned.
|
|
|
|
The format of the data returned is a character string consisting
|
|
of the word 'Yes' if a command is pending for the outlet or 'No'
|
|
if there is no command pending for the outlet. At least one
|
|
space will delimit each outlet entry in the string.
|
|
|
|
If the pending states are unknown, the character string 'Unknown'
|
|
will be returned. This signifies that there is an inconsistency
|
|
in the PDU. In the rare case that this should happen, the user
|
|
is advised to shut down all equipment powered by the PDU and then
|
|
cycle the PDU's power. This will put the PDU in a consistent state."
|
|
::= { sPDUMasterControl 3 }
|
|
|
|
|
|
-- the sPDUMasterConfig group
|
|
|
|
sPDUMasterConfigPowerOn OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The amount of delay, in seconds, between when
|
|
power is provided to the PDU and when the PDU
|
|
provides basic master power to the outlets.
|
|
|
|
Allowed values are:
|
|
|
|
-1 never apply power automatically.
|
|
0 apply power immediately.
|
|
15 apply power in 15 seconds.
|
|
30 apply power in 30 seconds.
|
|
45 apply power in 45 seconds.
|
|
60 apply power in 60 seconds (1 minute).
|
|
120 apply power in 120 seconds (2 minutes).
|
|
300 apply power in 300 seconds (5 minutes).
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the PDU interprets it as the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used."
|
|
|
|
::= { sPDUMasterConfig 1 }
|
|
|
|
sPDUMasterConfigReboot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"During a reboot sequence, power is turned off and then
|
|
back on. This OID defines the amount of time to wait,
|
|
in seconds, after turning the power off, at the start
|
|
of the sequence, before turning power back on, at the
|
|
end of the reboot sequence.
|
|
|
|
Allowed values are:
|
|
|
|
5 wait 5 seconds between off/on.
|
|
10 wait 10 seconds between off/on.
|
|
15 wait 15 seconds between off/on.
|
|
20 wait 20 seconds between off/on.
|
|
30 wait 30 seconds between off/on.
|
|
45 wait 45 seconds between off/on.
|
|
60 wait 60 seconds (1 minute) between off/on.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the PDU interprets it as the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used.
|
|
|
|
This OID is read-only for the MasterSwitch version 2.X and is the
|
|
maximum sPDUOutletRebootDuration OID of the individual outlets."
|
|
|
|
::= { sPDUMasterConfig 2 }
|
|
|
|
sPDUMasterConfigPDUName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the PDU."
|
|
::= { sPDUMasterConfig 3 }
|
|
|
|
|
|
|
|
-- the sPDUOutletControl group
|
|
sPDUOutletControlTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of outlets for the PDU."
|
|
::= { sPDUOutletControl 1 }
|
|
|
|
|
|
sPDUOutletControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUOutletControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of individual outlet switches. The number of
|
|
entries is contained in the sPDUOutletControlTableSize OID."
|
|
::= { sPDUOutletControl 2 }
|
|
|
|
sPDUOutletControlEntry OBJECT-TYPE
|
|
SYNTAX SPDUOutletControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to control."
|
|
INDEX { sPDUOutletControlIndex}
|
|
::= { sPDUOutletControlTable 1 }
|
|
|
|
SPDUOutletControlEntry ::=
|
|
SEQUENCE {
|
|
sPDUOutletControlIndex INTEGER,
|
|
sPDUOutletPending INTEGER,
|
|
sPDUOutletCtl INTEGER,
|
|
sPDUOutletCtlName DisplayString
|
|
}
|
|
|
|
sPDUOutletControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { sPDUOutletControlEntry 1 }
|
|
|
|
sPDUOutletPending OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
commandPending (1),
|
|
noCommandPending (2),
|
|
commandPendingUnknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reports whether the current outlet has a pending command.
|
|
|
|
If the commandPendingUnknown (3) value is returned, all
|
|
devices powered by the PDU should be shut down. The PDU's
|
|
power should then be cycled to clear this condition."
|
|
|
|
::= { sPDUOutletControlEntry 2 }
|
|
|
|
sPDUOutletCtl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletOn (1),
|
|
outletOff (2),
|
|
outletReboot (3),
|
|
outletUnknown (4),
|
|
outletOnWithDelay (5),
|
|
outletOffWithDelay (6),
|
|
outletRebootWithDelay (7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the outletOn (1) value will be returned.
|
|
If the outlet is off, the outletOff (2) value will be
|
|
returned.
|
|
|
|
If the state of the outlet cannot be determined, the
|
|
outletUnknown (4) value will be returned. If the
|
|
outletUnknown condition should occur, all devices
|
|
powered by the PDU should be shut down. The PDU's power
|
|
should then be cycled to clear this condition.
|
|
|
|
Setting this variable to outletOn (1) will turn the outlet on.
|
|
|
|
Setting this variable to outletOff (2) will turn the outlet off.
|
|
|
|
Setting this variable to outletReboot (3) will reboot the outlet.
|
|
|
|
Setting this variable to outletOnWithDelay (5) will turn the outlet on
|
|
after the sPDUOutletPowerOnTime OID has elapsed. This option is not
|
|
valid for MasterSwitch firmware version 1.X.
|
|
|
|
Setting this variable to outletOffWithDelay (6) will turn the outlet off
|
|
after the sPDUOutletPowerOffTime OID has elapsed. This option is not valid
|
|
for MasterSwitch firmware version 1.X.
|
|
|
|
Setting this variable to outletRebootWithDelay (7) will turn the outlet off
|
|
after the sPDUOutletPowerOffTime OID has elapsed, wait the sPDUOutletRebootDuration
|
|
OID time, then turn the outlet back on.
|
|
This option is not valid for MasterSwitch firmware version 1.X."
|
|
|
|
::= { sPDUOutletControlEntry 3 }
|
|
|
|
sPDUOutletCtlName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. Maximum size is 20 characters.
|
|
This OID is provided for informational purposes only.
|
|
This value is set by the sPDUOutletName OID."
|
|
|
|
::= { sPDUOutletControlEntry 4 }
|
|
|
|
-- the sPDUOutletConfig group
|
|
sPDUOutletConfigTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of outlets for the PDU."
|
|
::= { sPDUOutletConfig 1 }
|
|
|
|
sPDUOutletConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The list of outlets to configure. The number of
|
|
entries is defined by the sPDUOutletConfigTableSize
|
|
OID."
|
|
|
|
::= { sPDUOutletConfig 2 }
|
|
|
|
sPDUOutletConfigEntry OBJECT-TYPE
|
|
SYNTAX SPDUOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to control."
|
|
INDEX { sPDUOutletConfigIndex}
|
|
::= { sPDUOutletConfigTable 1 }
|
|
|
|
SPDUOutletConfigEntry ::=
|
|
SEQUENCE {
|
|
sPDUOutletConfigIndex INTEGER,
|
|
sPDUOutletPowerOnTime INTEGER,
|
|
sPDUOutletName DisplayString,
|
|
sPDUOutletPowerOffTime INTEGER,
|
|
sPDUOutletRebootDuration INTEGER
|
|
}
|
|
|
|
sPDUOutletConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { sPDUOutletConfigEntry 1 }
|
|
|
|
sPDUOutletPowerOnTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering on when the MasterSwitch is powered on.
|
|
|
|
Allowed values are:
|
|
|
|
-1 never power on automatically.
|
|
0 power on with the Master Switch.
|
|
15 power on 15 seconds after the MasterSwitch has power applied.
|
|
30 power on 30 seconds after the MasterSwitch has power applied.
|
|
45 power on 45 seconds after the MasterSwitch has power applied.
|
|
60 power on 60 seconds (1 minute) after the MasterSwitch has power applied.
|
|
120 power on 120 seconds (2 minutes) after the MasterSwitch has power applied.
|
|
300 power on 300 seconds (5 minutes) after the MasterSwitch has power applied.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the PDU interprets it as the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used."
|
|
|
|
::= { sPDUOutletConfigEntry 2 }
|
|
|
|
sPDUOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. Maximum size is 20 characters."
|
|
|
|
::= { sPDUOutletConfigEntry 3 }
|
|
|
|
sPDUOutletPowerOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering off.
|
|
|
|
Allowed values are:
|
|
|
|
-1 never power off automatically.
|
|
0 power off with the MasterSwitch.
|
|
15 power off 15 seconds after being commanded.
|
|
30 power off 30 seconds after being commanded.
|
|
45 power off 45 seconds after being commanded.
|
|
60 power off 60 seconds (1 minute) after being commanded.
|
|
120 power off 120 seconds (2 minutes) after being commanded.
|
|
300 power off 300 seconds (5 minutes) after being commanded.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the PDU interprets it as the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used.
|
|
|
|
This OID is not available for MasterSwitch firmware version 1.X."
|
|
|
|
::= { sPDUOutletConfigEntry 4 }
|
|
|
|
sPDUOutletRebootDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"During a reboot sequence, power is turned off and then
|
|
back on. This OID defines the amount of time to wait,
|
|
in seconds, after turning the power off, at the start
|
|
of the sequence, before turning power back on, at the
|
|
end of the reboot sequence.
|
|
|
|
Allowed values are:
|
|
|
|
5 wait 5 seconds between off/on.
|
|
10 wait 10 seconds between off/on.
|
|
15 wait 15 seconds between off/on.
|
|
20 wait 20 seconds between off/on.
|
|
30 wait 30 seconds between off/on.
|
|
45 wait 45 seconds between off/on.
|
|
60 wait 60 seconds (1 minute) between off/on.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the PDU interprets it as the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used.
|
|
|
|
This OID is not available for MasterSwitch firmware version 1.X."
|
|
|
|
::= { sPDUOutletConfigEntry 5 }
|
|
|
|
|
|
-- the sPDUIdentVM group
|
|
|
|
sPDUIdentVMTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of MasterSwitch VMs controllable
|
|
by this IP address."
|
|
::= { sPDUIdentVM 1 }
|
|
|
|
|
|
sPDUIdentVMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUIdentVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for query of the individual MasterSwitch VMs.
|
|
The number of entries is contained in the
|
|
sPDUIdentVMTableSize OID."
|
|
::= { sPDUIdentVM 2 }
|
|
|
|
sPDUIdentVMEntry OBJECT-TYPE
|
|
SYNTAX SPDUIdentVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MasterSwitch VMs to query."
|
|
INDEX { sPDUIdentVMIndex}
|
|
::= { sPDUIdentVMTable 1 }
|
|
|
|
SPDUIdentVMEntry ::=
|
|
SEQUENCE {
|
|
sPDUIdentVMIndex INTEGER,
|
|
sPDUIdentNameVM DisplayString,
|
|
sPDUIdentHardwareRevVM DisplayString,
|
|
sPDUIdentFirmwareRevVM DisplayString,
|
|
sPDUIdentDateOfManufactureVM DisplayString,
|
|
sPDUIdentModelNumberVM DisplayString,
|
|
sPDUIdentSerialNumberVM DisplayString
|
|
}
|
|
|
|
sPDUIdentVMIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch VM entry."
|
|
::= { sPDUIdentVMEntry 1 }
|
|
|
|
sPDUIdentNameVM OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 23-character string identifying the
|
|
MasterSwitch VM. "
|
|
::= { sPDUIdentVMEntry 2 }
|
|
|
|
sPDUIdentHardwareRevVM OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware version of the MasterSwitch VM.
|
|
This value is set at the factory."
|
|
::= { sPDUIdentVMEntry 3 }
|
|
|
|
sPDUIdentFirmwareRevVM OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An 6-character ID string identifying the MasterSwitch VM
|
|
firmware version. This value is set at the factory."
|
|
::= { sPDUIdentVMEntry 4 }
|
|
|
|
|
|
sPDUIdentDateOfManufactureVM OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the MasterSwitch VM was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory. "
|
|
::= { sPDUIdentVMEntry 5 }
|
|
|
|
sPDUIdentModelNumberVM OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 17-character string identifying the model number of
|
|
the MasterSwitch VM. This value is set at the factory."
|
|
::= { sPDUIdentVMEntry 6 }
|
|
|
|
sPDUIdentSerialNumberVM OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 17-character string identifying the serial number of
|
|
the MasterSwitch VM. This value is set at the factory."
|
|
::= { sPDUIdentVMEntry 7 }
|
|
|
|
|
|
-- the sPDUMasterControlVM group
|
|
|
|
sPDUMasterControlVMTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of MasterSwitch VMs controllable
|
|
by this IP address."
|
|
::= { sPDUMasterControlVM 1 }
|
|
|
|
|
|
sPDUMasterControlVMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUMasterControlVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of the individual MasterSwitch VMs.
|
|
The number of entries is contained in the
|
|
sPDUMasterControlVMTableSize OID."
|
|
::= { sPDUMasterControlVM 2 }
|
|
|
|
sPDUMasterControlVMEntry OBJECT-TYPE
|
|
SYNTAX SPDUMasterControlVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MasterSwitch VMs to control."
|
|
INDEX { sPDUMasterControlVMIndex}
|
|
::= { sPDUMasterControlVMTable 1 }
|
|
|
|
SPDUMasterControlVMEntry ::=
|
|
SEQUENCE {
|
|
sPDUMasterControlVMIndex INTEGER,
|
|
sPDUMasterControlVMName DisplayString,
|
|
sPDUMasterControlVMCommand INTEGER
|
|
}
|
|
|
|
sPDUMasterControlVMIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch VM entry."
|
|
::= { sPDUMasterControlVMEntry 1 }
|
|
|
|
sPDUMasterControlVMName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch VM. The maximum
|
|
value is 23 characters. The name is set by
|
|
using the sPDUMasterConfigVMName OID."
|
|
::= { sPDUMasterControlVMEntry 2 }
|
|
|
|
sPDUMasterControlVMCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noCommandAllVM (1),
|
|
immediateAllOnVM (2),
|
|
immediateAllOffVM (3),
|
|
immediateAllRebootVM (4),
|
|
delayedAllOnVM (5),
|
|
delayedAllOffVM (6),
|
|
sequencedAllRebootVM (7),
|
|
delayedAllRebootVM (8),
|
|
delayedSequenceAllRebootVM (9),
|
|
cancelAllPendingCommandsVM (10),
|
|
audioAlarmMute (11)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to immediateAllOnVM (2) will turn all outlets
|
|
on immediately.
|
|
|
|
Setting this OID to immediateAllOffVM (3) will turn all outlets
|
|
off immediately.
|
|
|
|
Setting this OID to immediateAllRebootVM (4) will reboot all outlets
|
|
immediately.
|
|
|
|
Setting this OID to delayedAllOnVM (5) will turn all outlets on as
|
|
defined by each outlet's sPDUOutletConfigVMPowerOnTime OID value.
|
|
|
|
Setting this OID to delayedAllOffVM (6) will turn all outlets
|
|
off as defined by each outlet's sPDUOutletConfigVMPowerOffTime OID value.
|
|
|
|
Setting this OID to sequencedAllRebootVM (7) will cause a
|
|
immediateAllOffVM command to be performed. The MasterSwitch VM will
|
|
then delay the sPDUMasterStatusVMRebootDuration OID time, and then
|
|
perform a delayedAllOnVM command.
|
|
|
|
Setting this OID to delayedAllRebootVM (8) will cause a delayedAllOffVM
|
|
command to be performed. Each outlet will then wait its
|
|
sPDUOutletConfigVMRebootDuration before returning power to the outlet.
|
|
|
|
Setting this OID to delayedSequenceAllRebootVM (9) will cause a
|
|
delayedAllOffVM command to be performed. Once all outlets are off,
|
|
the MasterSwitch VM will then delay the sPDUMasterStatusVMRebootDuration
|
|
OID time, and then perform a delayedAllOnVM command.
|
|
|
|
Setting this OID to cancelAllPendingCommandsVM (10) will cause all pending
|
|
commands on the MasterSwitch VM to be canceled.
|
|
|
|
|
|
Setting this OID to audioAlarmMute (11) will temporarily silence the audible
|
|
alarm for the duration of the current overload condition. The audible alarm
|
|
will be activated on subsequent overload alarms.
|
|
|
|
Getting this OID will return the noCommandAllVM (1) value."
|
|
::= { sPDUMasterControlVMEntry 3 }
|
|
|
|
|
|
-- the sPDUMasterConfigVM group
|
|
|
|
sPDUMasterConfigVMTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of MasterSwitch VMs configurable
|
|
by this IP address."
|
|
::= { sPDUMasterConfigVM 1 }
|
|
|
|
|
|
sPDUMasterConfigVMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUMasterConfigVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of the individual MasterSwitch VMs.
|
|
The number of entries is contained in the
|
|
sPDUMasterConfigVMTableSize OID."
|
|
::= { sPDUMasterConfigVM 2 }
|
|
|
|
sPDUMasterConfigVMEntry OBJECT-TYPE
|
|
SYNTAX SPDUMasterConfigVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MasterSwitch VMs to configure."
|
|
INDEX { sPDUMasterConfigVMIndex}
|
|
::= { sPDUMasterConfigVMTable 1 }
|
|
|
|
SPDUMasterConfigVMEntry ::=
|
|
SEQUENCE {
|
|
sPDUMasterConfigVMIndex INTEGER,
|
|
sPDUMasterConfigVMName DisplayString,
|
|
sPDUMasterConfigVMColdstartDelay INTEGER,
|
|
sPDUMasterConfigVMAudioAlarmActivated INTEGER,
|
|
sPDUMasterConfigVMHighLoadWarningThreshold INTEGER,
|
|
sPDUMasterConfigVMLowLoadWarningThreshold INTEGER,
|
|
sPDUMasterConfigVMOverloadRestriction INTEGER
|
|
}
|
|
|
|
sPDUMasterConfigVMIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch VM entry."
|
|
::= { sPDUMasterConfigVMEntry 1 }
|
|
|
|
|
|
sPDUMasterConfigVMName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch VM. Maximum size is 23 characters."
|
|
::= { sPDUMasterConfigVMEntry 2 }
|
|
|
|
sPDUMasterConfigVMColdstartDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The amount of delay, in seconds, between when
|
|
power is provided to the MasterSwitch VM and
|
|
when the MasterSwitch VM provides basic master
|
|
power to the outlets.
|
|
|
|
Allowed values are:
|
|
|
|
-1 never apply power automatically.
|
|
0 apply power immediately.
|
|
15 apply power in 15 seconds.
|
|
30 apply power in 30 seconds.
|
|
45 apply power in 45 seconds.
|
|
60 apply power in 60 seconds (1 minute).
|
|
120 apply power in 120 seconds (2 minutes).
|
|
300 apply power in 300 seconds (5 minutes).
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the MasterSwitch VM interprets it as the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used."
|
|
::= { sPDUMasterConfigVMEntry 3 }
|
|
|
|
sPDUMasterConfigVMAudioAlarmActivated OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
audioAlarmActiveNever (1),
|
|
audioAlarmActiveOnOverload (2),
|
|
audioAlarmActiveOnOverloadImminent (3)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to audioAlarmActiveNever (1) will disable
|
|
the audio alarm on the MasterSwitch VM.
|
|
|
|
Setting this OID to audioAlarmActiveOnOverload (2) will
|
|
activate the audio alarm on the MasterSwitch VM when an
|
|
overload condition is present.
|
|
|
|
Setting this OID to audioAlarmActiveOnOverloadImminent (3)
|
|
will activate the audio alarm on the MasterSwitch VM when
|
|
the load on the MasterSwitch VM has surpassed the
|
|
sPDUMasterConfigVMHighLoadWarningThreshold OID value."
|
|
::= { sPDUMasterConfigVMEntry 4 }
|
|
|
|
sPDUMasterConfigVMHighLoadWarningThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing an overload condition. It is
|
|
represented as a percentage of full load."
|
|
::= { sPDUMasterConfigVMEntry 5 }
|
|
|
|
sPDUMasterConfigVMLowLoadWarningThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing a low consumption condition. It is
|
|
represented as a percentage of full load."
|
|
::= { sPDUMasterConfigVMEntry 6 }
|
|
|
|
sPDUMasterConfigVMOverloadRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysAllowTurnON (1),
|
|
restrictOnWarning (2),
|
|
restrictOnOverload (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of the MasterSwitch VM
|
|
when an overload condition is possible and additional
|
|
outlets are requested to be turned on.
|
|
|
|
Setting this OID to alwaysAllowTurnON (1) will always allow
|
|
the outlets to turn on.
|
|
|
|
Setting this OID to restrictOnWarning (2) will not allow
|
|
outlets to turn on if the sPDUMasterConfigVMHighLoadWarningThreshold
|
|
OID is exceeded.
|
|
|
|
Setting this OID to restrictOnOverload (3) will not allow
|
|
outlets to turn on if the MasterSwitch Vm is in an
|
|
overload condition."
|
|
::= { sPDUMasterConfigVMEntry 7 }
|
|
|
|
-- the sPDUMasterStatusVM group
|
|
|
|
sPDUMasterStatusVMTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of MasterSwitch VMs at
|
|
this IP address."
|
|
::= { sPDUMasterStatusVM 1 }
|
|
|
|
|
|
sPDUMasterStatusVMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUMasterStatusVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for gathering of status from the individual
|
|
MasterSwitch VMs. The number of entries is contained
|
|
in the sPDUMasterStatusVMTableSize OID."
|
|
::= { sPDUMasterStatusVM 2 }
|
|
|
|
sPDUMasterStatusVMEntry OBJECT-TYPE
|
|
SYNTAX SPDUMasterStatusVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MasterSwitch VMs to gather status from."
|
|
INDEX { sPDUMasterStatusVMIndex}
|
|
::= { sPDUMasterStatusVMTable 1 }
|
|
|
|
SPDUMasterStatusVMEntry ::=
|
|
SEQUENCE {
|
|
sPDUMasterStatusVMIndex INTEGER,
|
|
sPDUMasterStatusVMName DisplayString,
|
|
sPDUMasterStatusVMCommandPending INTEGER,
|
|
sPDUMasterStatusVMOverloadCondition INTEGER,
|
|
sPDUMasterStatusVMLowLoadCondition INTEGER,
|
|
sPDUMasterStatusVMCurrentLoad INTEGER,
|
|
sPDUMasterStatusVMMaxLoad INTEGER,
|
|
sPDUMasterStatusVMOutletCount INTEGER,
|
|
sPDUMasterStatusVMRebootDuration INTEGER
|
|
}
|
|
|
|
sPDUMasterStatusVMIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch VM entry."
|
|
::= { sPDUMasterStatusVMEntry 1 }
|
|
|
|
sPDUMasterStatusVMName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch VM. Maximum size is 23 characters."
|
|
::= { sPDUMasterStatusVMEntry 2 }
|
|
|
|
sPDUMasterStatusVMCommandPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
commandPendingMasterTrueVM (1),
|
|
commandPendingMasterFalseVM (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return commandPendingMasterTrueVM (1)
|
|
if the MasterSwitch VM has a pending command on any of its
|
|
outlets.
|
|
|
|
commandPendingMasterFalseVM (2) will be returned if there are
|
|
no pending commands."
|
|
::= { sPDUMasterStatusVMEntry 3 }
|
|
|
|
sPDUMasterStatusVMOverloadCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
overloadConditionTrueVM (1),
|
|
overloadConditionFalseVM (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return overloadConditionTrueVM (1)
|
|
if the sPDUMasterConfigVMHighLoadWarningThreshold OID is
|
|
violated.
|
|
|
|
overloadConditionFalseVM (2) will be returned if the
|
|
sPDUMasterConfigVMHighLoadWarningThreshold OID is not
|
|
violated."
|
|
::= { sPDUMasterStatusVMEntry 4 }
|
|
|
|
sPDUMasterStatusVMLowLoadCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lowLoadConditionTrueVM (1),
|
|
lowLoadConditionFalseVM (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return lowLoadConditionTrueVM (1)
|
|
if the sPDUMasterConfigVMLowLoadWarningThreshold OID is
|
|
violated.
|
|
|
|
lowLoadConditionFalseVM (2) will be returned if the
|
|
sPDUMasterConfigVMHighLoadWarningThreshold OID is not
|
|
violated. "
|
|
::= { sPDUMasterStatusVMEntry 5 }
|
|
|
|
sPDUMasterStatusVMCurrentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the total amount of power
|
|
being consumed by the load. It is represented as a
|
|
percentage of full load."
|
|
::= { sPDUMasterStatusVMEntry 6 }
|
|
|
|
sPDUMasterStatusVMMaxLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the total amount of power
|
|
that this MasterSwitch VM can provide. It is represented
|
|
in Amps."
|
|
::= { sPDUMasterStatusVMEntry 7 }
|
|
|
|
sPDUMasterStatusVMOutletCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the number of controllable
|
|
outlets for this MasterSwitch VM."
|
|
::= { sPDUMasterStatusVMEntry 8 }
|
|
|
|
sPDUMasterStatusVMRebootDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the largest
|
|
sPDUOutletConfigVMRebootDuration OID time
|
|
for this MasterSwitch VM."
|
|
::= { sPDUMasterStatusVMEntry 9 }
|
|
|
|
-- the sPDUOutletControlVM group
|
|
|
|
|
|
sPDUOutletControlVMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUOutletControlVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of individual outlet switches. The number of
|
|
entries is contained in the sPDUMasterStatusOutletCount OID."
|
|
::= { sPDUOutletControlVM 1 }
|
|
|
|
sPDUOutletControlVMEntry OBJECT-TYPE
|
|
SYNTAX SPDUOutletControlVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to control."
|
|
INDEX { sPDUOutletControlVMIndex, sPDUOutletControlVMOutletIndex }
|
|
::= { sPDUOutletControlVMTable 1 }
|
|
|
|
SPDUOutletControlVMEntry ::=
|
|
SEQUENCE {
|
|
sPDUOutletControlVMIndex INTEGER,
|
|
sPDUOutletControlVMName DisplayString,
|
|
sPDUOutletControlVMOutletIndex INTEGER,
|
|
sPDUOutletControlVMOutletName DisplayString,
|
|
sPDUOutletControlVMOutletCommand INTEGER
|
|
}
|
|
|
|
sPDUOutletControlVMIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch VM."
|
|
::= { sPDUOutletControlVMEntry 1 }
|
|
|
|
sPDUOutletControlVMName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch VM. Maximum size is 23 characters.
|
|
This OID is provided for informational purposes only."
|
|
::= { sPDUOutletControlVMEntry 2 }
|
|
|
|
sPDUOutletControlVMOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { sPDUOutletControlVMEntry 3 }
|
|
|
|
sPDUOutletControlVMOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. Maximum size is 23 characters.
|
|
This OID is provided for informational purposes only."
|
|
::= { sPDUOutletControlVMEntry 4 }
|
|
|
|
sPDUOutletControlVMOutletCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
immediateOnVM (1),
|
|
immediateOffVM (2),
|
|
immediateRebootVM (3),
|
|
delayedOnVM (4),
|
|
delayedOffVM (5),
|
|
delayedRebootVM (6),
|
|
cancelPendingCommandVM (7)
|
|
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the immediateOnVM (1) value will be returned.
|
|
If the outlet is off, the immediateOffVM (2) value will be
|
|
returned.
|
|
|
|
|
|
Setting this variable to immediateOnVM (1) will immediately turn the outlet on.
|
|
|
|
Setting this variable to immediateOffVM (2) will immediately turn the outlet off.
|
|
|
|
Setting this variable to immediateRebootVM (3) will immediately reboot the outlet.
|
|
|
|
Setting this variable to delayedOnVM (4) will turn the outlet on
|
|
after the sPDUOutletConfigVMPowerOnTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedOffVM (5) will turn the outlet off
|
|
after the sPDUOutletConfigVMPowerOffTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedRebootVM (6) will cause the
|
|
MasterSwitch VM to perform a delayedOffVM command, wait the
|
|
sPDUOutletConfigVMRebootDuration OID time, and then perform the
|
|
immediateOnVM command.
|
|
|
|
Setting this variable to cancelPendingCommandVM (7) will cause any
|
|
pending command to this outlet to be canceled."
|
|
::= { sPDUOutletControlVMEntry 5 }
|
|
|
|
-- the sPDUOutletConfigVM group
|
|
|
|
sPDUOutletConfigVMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUOutletConfigVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual outlets. The number of
|
|
entries is contained in the sPDUMasterStatusOutletCount OID."
|
|
::= { sPDUOutletConfigVM 1 }
|
|
|
|
sPDUOutletConfigVMEntry OBJECT-TYPE
|
|
SYNTAX SPDUOutletConfigVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to configure."
|
|
INDEX { sPDUOutletConfigVMIndex, sPDUOutletConfigVMOutletIndex }
|
|
::= { sPDUOutletConfigVMTable 1 }
|
|
|
|
SPDUOutletConfigVMEntry ::=
|
|
SEQUENCE {
|
|
sPDUOutletConfigVMIndex INTEGER,
|
|
sPDUOutletConfigVMName DisplayString,
|
|
sPDUOutletConfigVMOutletIndex INTEGER,
|
|
sPDUOutletConfigVMOutletName DisplayString,
|
|
sPDUOutletConfigVMPowerOnTime INTEGER,
|
|
sPDUOutletConfigVMPowerOffTime INTEGER,
|
|
sPDUOutletConfigVMRebootDuration INTEGER
|
|
}
|
|
|
|
sPDUOutletConfigVMIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch VM."
|
|
::= { sPDUOutletConfigVMEntry 1 }
|
|
|
|
sPDUOutletConfigVMName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch VM. Maximum size is 23 characters."
|
|
::= { sPDUOutletConfigVMEntry 2 }
|
|
|
|
sPDUOutletConfigVMOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { sPDUOutletConfigVMEntry 3 }
|
|
|
|
|
|
sPDUOutletConfigVMOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. Maximum size is 23 characters."
|
|
::= { sPDUOutletConfigVMEntry 4 }
|
|
|
|
sPDUOutletConfigVMPowerOnTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering on at coldstart or when a command that requires
|
|
a turn-on delay is issued.
|
|
|
|
Allowed values are:
|
|
|
|
-1 never power on.
|
|
0 power on immediately.
|
|
15 power on 15 seconds after being commanded.
|
|
30 power on 30 seconds after being commanded.
|
|
45 power on 45 seconds after being commanded.
|
|
60 power on 60 seconds (1 minute) after being commanded.
|
|
120 power on 120 seconds (2 minutes) after being commanded.
|
|
300 power on 300 seconds (5 minutes) after being commanded.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the MasterSwitch VM interprets it as the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used."
|
|
::= { sPDUOutletConfigVMEntry 5 }
|
|
|
|
|
|
sPDUOutletConfigVMPowerOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering off when a command that requires
|
|
a turn-off delay is issued.
|
|
|
|
|
|
Allowed values are:
|
|
|
|
-1 never power off automatically.
|
|
0 power off immediately.
|
|
15 power off 15 seconds after being commanded.
|
|
30 power off 30 seconds after being commanded.
|
|
45 power off 45 seconds after being commanded.
|
|
60 power off 60 seconds (1 minute) after being commanded.
|
|
120 power off 120 seconds (2 minutes) after being commanded.
|
|
300 power off 300 seconds (5 minutes) after being commanded.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the MasterSwitch VM interprets it as the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used."
|
|
::= { sPDUOutletConfigVMEntry 6 }
|
|
|
|
sPDUOutletConfigVMRebootDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"During a reboot sequence, power is turned off and then
|
|
back on. This OID defines the amount of time to wait,
|
|
in seconds, after turning the power off, at the start
|
|
of the sequence, before turning power back on, at the
|
|
end of the reboot sequence.
|
|
|
|
Allowed values are:
|
|
|
|
5 wait 5 seconds between off/on.
|
|
10 wait 10 seconds between off/on.
|
|
15 wait 15 seconds between off/on.
|
|
20 wait 20 seconds between off/on.
|
|
30 wait 30 seconds between off/on.
|
|
45 wait 45 seconds between off/on.
|
|
60 wait 60 seconds (1 minute) between off/on.
|
|
|
|
If a value other than a supported value is provided in a
|
|
set request, the MasterSwitch VM interprets it as the next lower
|
|
acceptable value. If the provided value is lower than
|
|
the lowest acceptable value, the lowest acceptable
|
|
value is used."
|
|
::= { sPDUOutletConfigVMEntry 7 }
|
|
|
|
-- the sPDUOutletStatusVM group
|
|
|
|
sPDUOutletStatusVMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUOutletStatusVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of individual outlets. The number of
|
|
entries is contained in the sPDUMasterStatusOutletCount OID."
|
|
::= { sPDUOutletStatusVM 1 }
|
|
|
|
sPDUOutletStatusVMEntry OBJECT-TYPE
|
|
SYNTAX SPDUOutletStatusVMEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to gather status from."
|
|
INDEX { sPDUOutletStatusVMIndex, sPDUOutletStatusVMOutletIndex }
|
|
::= { sPDUOutletStatusVMTable 1 }
|
|
|
|
SPDUOutletStatusVMEntry ::=
|
|
SEQUENCE {
|
|
sPDUOutletStatusVMIndex INTEGER,
|
|
sPDUOutletStatusVMName DisplayString,
|
|
sPDUOutletStatusVMOutletIndex INTEGER,
|
|
sPDUOutletStatusVMOutletName DisplayString,
|
|
sPDUOutletStatusVMOutletState INTEGER,
|
|
sPDUOutletStatusVMCommandPending INTEGER
|
|
}
|
|
|
|
sPDUOutletStatusVMIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch VM."
|
|
::= { sPDUOutletStatusVMEntry 1 }
|
|
|
|
sPDUOutletStatusVMName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch VM. Maximum size is 23 characters."
|
|
::= { sPDUOutletStatusVMEntry 2 }
|
|
|
|
sPDUOutletStatusVMOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { sPDUOutletStatusVMEntry 3 }
|
|
|
|
sPDUOutletStatusVMOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. Maximum size is 23 characters."
|
|
::= { sPDUOutletStatusVMEntry 4 }
|
|
|
|
sPDUOutletStatusVMOutletState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusVMOn (1),
|
|
outletStatusVMOff (2)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the outletStatusOnVM (1) value will be returned.
|
|
If the outlet is off, the outletStatusOffVM (2) value will be
|
|
returned. "
|
|
::= { sPDUOutletStatusVMEntry 5 }
|
|
|
|
sPDUOutletStatusVMCommandPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusVMCommandPending (1),
|
|
outletStatusVMNoCommandPending (2)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the command pending
|
|
state of the outlet. If a command is pending on the
|
|
outlet, the outletStatusVMCommandPending (1) value
|
|
will be returned. If there is not a command pending
|
|
on the outlet, the outletStatusVMNoCommandPending (2)
|
|
will be returned."
|
|
::= { sPDUOutletStatusVMEntry 6 }
|
|
|
|
-- the sPDUIdentMSP group
|
|
|
|
sPDUIdentMSPTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of MasterSwitch pluses controllable
|
|
by this IP address."
|
|
::= { sPDUIdentMSP 1 }
|
|
|
|
|
|
sPDUIdentMSPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUIdentMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for query of the individual MasterSwitch pluses.
|
|
The number of entries is contained in the
|
|
sPDUIdentMSPTableSize OID."
|
|
::= { sPDUIdentMSP 2 }
|
|
|
|
sPDUIdentMSPEntry OBJECT-TYPE
|
|
SYNTAX SPDUIdentMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MasterSwitch pluses to query."
|
|
INDEX { sPDUIdentMSPIndex}
|
|
::= { sPDUIdentMSPTable 1 }
|
|
|
|
SPDUIdentMSPEntry ::=
|
|
SEQUENCE {
|
|
sPDUIdentMSPIndex INTEGER,
|
|
sPDUIdentNameMSP DisplayString,
|
|
sPDUIdentHardwareRevMSP DisplayString,
|
|
sPDUIdentFirmwareRevMSP DisplayString,
|
|
sPDUIdentDateOfManufactureMSP DisplayString,
|
|
sPDUIdentModelNumberMSP DisplayString,
|
|
sPDUIdentSerialNumberMSP DisplayString
|
|
}
|
|
|
|
sPDUIdentMSPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch plus entry."
|
|
::= { sPDUIdentMSPEntry 1 }
|
|
|
|
sPDUIdentNameMSP OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch plus. The maximum
|
|
value is 23 characters. The name is set by
|
|
using the sPDUMasterConfigMSPName OID."
|
|
::= { sPDUIdentMSPEntry 2 }
|
|
|
|
sPDUIdentHardwareRevMSP OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware version of the MasterSwitch plus.
|
|
This value is set at the factory."
|
|
::= { sPDUIdentMSPEntry 3 }
|
|
|
|
sPDUIdentFirmwareRevMSP OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An 6-character ID string identifying the MasterSwitch plus
|
|
firmware version. This value is set at the factory."
|
|
::= { sPDUIdentMSPEntry 4 }
|
|
|
|
sPDUIdentDateOfManufactureMSP OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the MasterSwitch plus was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory. "
|
|
::= { sPDUIdentMSPEntry 5 }
|
|
|
|
sPDUIdentModelNumberMSP OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 17-character string identifying the model number of
|
|
the MasterSwitch plus. This value is set at the factory."
|
|
::= { sPDUIdentMSPEntry 6 }
|
|
|
|
sPDUIdentSerialNumberMSP OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 17-character string identifying the serial number of
|
|
the MasterSwitch plus. This value is set at the factory."
|
|
::= { sPDUIdentMSPEntry 7 }
|
|
|
|
|
|
-- the sPDUMasterControlMSP group
|
|
|
|
sPDUMasterControlMSPTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of MasterSwitch pluses controllable
|
|
by this IP address."
|
|
::= { sPDUMasterControlMSP 1 }
|
|
|
|
sPDUMasterControlMSPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUMasterControlMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of the individual MasterSwitch pluses.
|
|
The number of entries is contained in the
|
|
sPDUMasterControlMSPTableSize OID."
|
|
::= { sPDUMasterControlMSP 2 }
|
|
|
|
sPDUMasterControlMSPEntry OBJECT-TYPE
|
|
SYNTAX SPDUMasterControlMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MasterSwitch pluses to control."
|
|
INDEX { sPDUMasterControlMSPIndex}
|
|
::= { sPDUMasterControlMSPTable 1 }
|
|
|
|
SPDUMasterControlMSPEntry ::=
|
|
SEQUENCE {
|
|
sPDUMasterControlMSPIndex INTEGER,
|
|
sPDUMasterControlMSPName DisplayString,
|
|
sPDUMasterControlMSPCommand INTEGER
|
|
}
|
|
|
|
sPDUMasterControlMSPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch plus entry."
|
|
::= { sPDUMasterControlMSPEntry 1 }
|
|
|
|
sPDUMasterControlMSPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch plus. The maximum
|
|
value is 23 characters. The name is set by
|
|
using the sPDUMasterConfigMSPName OID."
|
|
::= { sPDUMasterControlMSPEntry 2 }
|
|
|
|
sPDUMasterControlMSPCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noCommandAllMSP (1),
|
|
immediateAllOnMSP (2),
|
|
sequencedAllOnMSP (3),
|
|
immediateAllOffMSP (4),
|
|
gracefulAllRebootMSP (5),
|
|
immediateAllRebootMSP (6),
|
|
gracefulAllShutdownMSP (7),
|
|
overrideAllBatCapThreshMSP (8),
|
|
cancelAllPendingCommandsMSP (9),
|
|
restoreFactoryDefaultsMSP (10)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to immediateAllOnMSP (2) will turn all outlets
|
|
on immediately.
|
|
|
|
Setting this OID to sequencedAllOnMSP (3) will turn all outlets
|
|
on as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay OID value.
|
|
|
|
Setting this OID to immediateAllOffMSP (4) will turn all outlets
|
|
off immediately.
|
|
|
|
Setting this OID to gracefulAllRebootMSP (5) will reboot all outlets
|
|
(after the device running PowerChute confirms shutdown) as defined
|
|
by each outlet's sPDUOutletConfigMSPRebootDuration OID time value.
|
|
|
|
Setting this OID to immediateAllRebootMSP (6) will reboot all outlets
|
|
immediately.
|
|
|
|
Setting this OID to gracefulAllShutdownMSP (7) will shutdown all outlets
|
|
(after the device running PowerChute confirms shutdown) as defined
|
|
by each outlet's sPDUOutletConfigMSPPowerOffDelay OID time value. Each
|
|
outlet will then turn on after the sum of its
|
|
sPDUOutletConfigMSPRestartDelay and sPDUOutletConfigMSPPowerOnDelay OID
|
|
values.
|
|
|
|
Setting this OID to overrideAllBatCapThreshMSP (8) will cause the
|
|
outlet to ignore the Battery Capacity Threshold and proceed turning on
|
|
the outlets as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay
|
|
OID value.
|
|
|
|
Setting this OID to cancelAllPendingCommandsMSP (9) will cause all pending
|
|
commands on the MasterSwitch plus to be canceled.
|
|
|
|
Setting this OID to restoreFactoryDefaultsMSP (10) will cause the settings of
|
|
the MasterSwitch plus to be restored to the factory defaults.
|
|
|
|
Getting this OID will return the noCommandAllMSP (1) value."
|
|
::= { sPDUMasterControlMSPEntry 3 }
|
|
|
|
|
|
-- the sPDUMasterConfigMSP group
|
|
|
|
sPDUMasterConfigMSPTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of MasterSwitch pluses configurable
|
|
by this IP address."
|
|
::= { sPDUMasterConfigMSP 1 }
|
|
|
|
sPDUMasterConfigMSPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUMasterConfigMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of the individual MasterSwitch pluses.
|
|
The number of entries is contained in the
|
|
sPDUMasterConfigMSPTableSize OID."
|
|
::= { sPDUMasterConfigMSP 2 }
|
|
|
|
sPDUMasterConfigMSPEntry OBJECT-TYPE
|
|
SYNTAX SPDUMasterConfigMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MasterSwitch pluses to configure."
|
|
INDEX { sPDUMasterConfigMSPIndex}
|
|
::= { sPDUMasterConfigMSPTable 1 }
|
|
|
|
SPDUMasterConfigMSPEntry ::=
|
|
SEQUENCE {
|
|
sPDUMasterConfigMSPIndex INTEGER,
|
|
sPDUMasterConfigMSPName DisplayString,
|
|
sPDUMasterConfigMSPPowerOnTimeDelay INTEGER,
|
|
sPDUMasterConfigMSPManualButton INTEGER
|
|
}
|
|
|
|
sPDUMasterConfigMSPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch plus entry."
|
|
::= { sPDUMasterConfigMSPEntry 1 }
|
|
|
|
sPDUMasterConfigMSPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch plus. Maximum size is 23 characters."
|
|
::= { sPDUMasterConfigMSPEntry 2 }
|
|
|
|
sPDUMasterConfigMSPPowerOnTimeDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (0..9999)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The amount of delay, in seconds, between when
|
|
power is provided to the MasterSwitch plus and
|
|
when the MasterSwitch plus provides basic master
|
|
power to the outlets.
|
|
|
|
Allowed values are:
|
|
|
|
0 - 9999 seconds (0 - 2hrs, 46 mins, 39 secs).
|
|
0 indicates to apply power immediately."
|
|
::= { sPDUMasterConfigMSPEntry 3 }
|
|
|
|
|
|
sPDUMasterConfigMSPManualButton OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manualButtonDisabled (1),
|
|
manualButtonEnabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to manualButtonDisabled (1) will disable
|
|
the manual button on the MasterSwitch plus.
|
|
|
|
Setting this OID to manualButtonEnabled (2) will enable
|
|
the manual button on the MasterSwitch plus."
|
|
::= { sPDUMasterConfigMSPEntry 4 }
|
|
|
|
-- the sPDUMasterStatusMSP group
|
|
|
|
sPDUMasterStatusMSPTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of MasterSwitch pluses at
|
|
this IP address."
|
|
::= { sPDUMasterStatusMSP 1 }
|
|
|
|
|
|
sPDUMasterStatusMSPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUMasterStatusMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for gathering of status from the individual
|
|
MasterSwitch pluses. The number of entries is contained
|
|
in the sPDUMasterStatusMSPTableSize OID."
|
|
::= { sPDUMasterStatusMSP 2 }
|
|
|
|
sPDUMasterStatusMSPEntry OBJECT-TYPE
|
|
SYNTAX SPDUMasterStatusMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MasterSwitch pluses to gather status from."
|
|
INDEX { sPDUMasterStatusMSPIndex}
|
|
::= { sPDUMasterStatusMSPTable 1 }
|
|
|
|
SPDUMasterStatusMSPEntry ::=
|
|
SEQUENCE {
|
|
sPDUMasterStatusMSPIndex INTEGER,
|
|
sPDUMasterStatusMSPName DisplayString,
|
|
sPDUMasterStatusMSPOutletCount INTEGER
|
|
}
|
|
|
|
sPDUMasterStatusMSPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch plus entry."
|
|
::= { sPDUMasterStatusMSPEntry 1 }
|
|
|
|
sPDUMasterStatusMSPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch plus. The maximum
|
|
value is 23 characters. The name is set by
|
|
using the sPDUMasterConfigMSPName OID."
|
|
::= { sPDUMasterStatusMSPEntry 2 }
|
|
|
|
sPDUMasterStatusMSPOutletCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the number of controllable
|
|
outlets for this MasterSwitch plus."
|
|
::= { sPDUMasterStatusMSPEntry 3 }
|
|
|
|
-- the sPDUOutletControlMSP group
|
|
|
|
sPDUOutletControlMSPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUOutletControlMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of individual outlet switches. The number of
|
|
entries is contained in the sPDUMasterStatusMSPOutletCount OID."
|
|
::= { sPDUOutletControlMSP 1 }
|
|
|
|
sPDUOutletControlMSPEntry OBJECT-TYPE
|
|
SYNTAX SPDUOutletControlMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to control."
|
|
INDEX { sPDUOutletControlMSPIndex, sPDUOutletControlMSPOutletIndex }
|
|
::= { sPDUOutletControlMSPTable 1 }
|
|
|
|
SPDUOutletControlMSPEntry ::=
|
|
SEQUENCE {
|
|
sPDUOutletControlMSPIndex INTEGER,
|
|
sPDUOutletControlMSPName DisplayString,
|
|
sPDUOutletControlMSPOutletIndex INTEGER,
|
|
sPDUOutletControlMSPOutletName DisplayString,
|
|
sPDUOutletControlMSPOutletCommand INTEGER
|
|
}
|
|
|
|
sPDUOutletControlMSPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch plus."
|
|
::= { sPDUOutletControlMSPEntry 1 }
|
|
|
|
sPDUOutletControlMSPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch plus. The maximum
|
|
value is 23 characters. The name is set by
|
|
using the sPDUMasterConfigMSPName OID."
|
|
::= { sPDUOutletControlMSPEntry 2 }
|
|
|
|
sPDUOutletControlMSPOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { sPDUOutletControlMSPEntry 3 }
|
|
|
|
sPDUOutletControlMSPOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum size is
|
|
23 characters. The name is set by using the
|
|
sPDUOutletConfigMSPallOutletName OID.
|
|
This OID is provided for informational purposes only."
|
|
::= { sPDUOutletControlMSPEntry 4 }
|
|
|
|
sPDUOutletControlMSPOutletCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
immediateOnMSP (1),
|
|
delayedOnMSP (2),
|
|
immediateOffMSP (3),
|
|
gracefulRebootMSP (4),
|
|
immediateRebootMSP (5),
|
|
gracefulshutdownMSP (6),
|
|
overrideBatCapThreshMSP (7),
|
|
cancelPendingCommandMSP (8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the immediateOnMSP (1) value will be returned.
|
|
If the outlet is off, the immediateOffMSP (3) value will be
|
|
returned.
|
|
|
|
Setting this variable to immediateOnMSP (1) will immediately turn the outlet on.
|
|
|
|
Setting this variable to delayedOnMSP (2) will turn the outlet on
|
|
after the sPDUOutletConfigMSPPowerOnDelay OID time has elapsed.
|
|
|
|
Setting this variable to immediateOffMSP (3) will immediately turn the outlet off.
|
|
|
|
Setting this variable to gracefulRebootMSP (4) will cause the outlet to wait for
|
|
device confirmation (if applicable) and then turn the outlet off after the
|
|
sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn
|
|
on after the sPDUOutletConfigMSPRebootDuration OID time has elapsed.
|
|
|
|
Setting this variable to immediateRebootMSP (5) will immediately reboot the outlet.
|
|
|
|
Setting this variable to gracefulshutdownMSP (6) will cause the outlet to wait for
|
|
device confirmation (if applicable) and then turn the outlet off after the
|
|
sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn
|
|
on after the sum of the sPDUOutletConfigMSPRestartTime OID time and the
|
|
sPDUOutletConfigMSPPowerOnDelay OID time has elapsed.
|
|
|
|
Setting this variable to overrideBatCapThreshMSP (7) will cause the outlet to
|
|
ignore the Battery Capacity Threshold and proceed waiting on the
|
|
sPDUOutletConfigMSPPowerOnDelay OID time before turning the outlet on.
|
|
|
|
Setting this variable to cancelPendingCommandMSP (8) will cause any
|
|
pending command to this outlet to be canceled."
|
|
::= { sPDUOutletControlMSPEntry 5 }
|
|
|
|
-- the sPDUOutletConfigMSPall group
|
|
|
|
sPDUOutletConfigMSPallTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUOutletConfigMSPallEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual outlets. The number of
|
|
entries is contained in the sPDUMasterStatusMSPOutletCount OID."
|
|
::= { sPDUOutletConfigMSPall 1 }
|
|
|
|
sPDUOutletConfigMSPallEntry OBJECT-TYPE
|
|
SYNTAX SPDUOutletConfigMSPallEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to configure."
|
|
INDEX { sPDUOutletConfigMSPallIndex, sPDUOutletConfigMSPallOutletIndex }
|
|
::= { sPDUOutletConfigMSPallTable 1 }
|
|
|
|
SPDUOutletConfigMSPallEntry ::=
|
|
SEQUENCE {
|
|
sPDUOutletConfigMSPallIndex INTEGER,
|
|
sPDUOutletConfigMSPallName DisplayString,
|
|
sPDUOutletConfigMSPallOutletIndex INTEGER,
|
|
sPDUOutletConfigMSPallOutletName DisplayString,
|
|
sPDUOutletConfigMSPallOutletCtrlMode INTEGER
|
|
}
|
|
|
|
sPDUOutletConfigMSPallIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch plus."
|
|
::= { sPDUOutletConfigMSPallEntry 1 }
|
|
|
|
sPDUOutletConfigMSPallName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch plus. The maximum
|
|
value is 23 characters. The name is set by
|
|
using the sPDUMasterConfigMSPName OID."
|
|
::= { sPDUOutletConfigMSPallEntry 2 }
|
|
|
|
sPDUOutletConfigMSPallOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { sPDUOutletConfigMSPallEntry 3 }
|
|
|
|
sPDUOutletConfigMSPallOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. Maximum size is 23 characters."
|
|
::= { sPDUOutletConfigMSPallEntry 4 }
|
|
|
|
sPDUOutletConfigMSPallOutletCtrlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modeGracefulShutdown (1),
|
|
modeAnnunciator (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to modeGracefulShutdown (1) will put this
|
|
outlet into the Graceful Shutdown control mode.
|
|
|
|
Setting this OID to modeAnnunciator (2) will put this outlet
|
|
into the Annunciator control mode."
|
|
::= { sPDUOutletConfigMSPallEntry 5 }
|
|
|
|
|
|
-- the sPDUOutConfigMSPgs group
|
|
|
|
sPDUOutletConfigMSPgsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUOutletConfigMSPgsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual outlets. The number of
|
|
entries is contained in the sPDUMasterStatusMSPOutletCount OID."
|
|
::= { sPDUOutletConfigMSPgs 1 }
|
|
|
|
sPDUOutletConfigMSPgsEntry OBJECT-TYPE
|
|
SYNTAX SPDUOutletConfigMSPgsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to configure."
|
|
INDEX { sPDUOutletConfigMSPgsIndex, sPDUOutletConfigMSPgsOutletIndex }
|
|
::= { sPDUOutletConfigMSPgsTable 1 }
|
|
|
|
SPDUOutletConfigMSPgsEntry ::=
|
|
SEQUENCE {
|
|
sPDUOutletConfigMSPgsIndex INTEGER,
|
|
sPDUOutletConfigMSPgsName DisplayString,
|
|
sPDUOutletConfigMSPgsOutletIndex INTEGER,
|
|
sPDUOutletConfigMSPgsOutletName DisplayString,
|
|
sPDUOutletConfigMSPgsOutletCtrlMode INTEGER,
|
|
sPDUOutletConfigMSPgsDeviceConfirm INTEGER,
|
|
sPDUOutletConfigMSPgsLowBattWarning INTEGER,
|
|
sPDUOutletConfigMSPgsLowBattMult INTEGER,
|
|
sPDUOutletConfigMSPgsRestartDelay INTEGER,
|
|
sPDUOutletConfigMSPgsPowerOnDelay INTEGER,
|
|
sPDUOutletConfigMSPgsPowerOffDelay INTEGER,
|
|
sPDUOutletConfigMSPgsBattCapThresh INTEGER,
|
|
sPDUOutletConfigMSPgsRebootDuration INTEGER
|
|
}
|
|
|
|
sPDUOutletConfigMSPgsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch plus."
|
|
::= { sPDUOutletConfigMSPgsEntry 1 }
|
|
|
|
sPDUOutletConfigMSPgsName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch plus. The maximum
|
|
value is 23 characters. The name is set by
|
|
using the sPDUMasterConfigMSPName OID."
|
|
::= { sPDUOutletConfigMSPgsEntry 2 }
|
|
|
|
sPDUOutletConfigMSPgsOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { sPDUOutletConfigMSPgsEntry 3 }
|
|
|
|
sPDUOutletConfigMSPgsOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum size is
|
|
23 characters. The name is set by using the
|
|
sPDUOutletConfigMSPallOutletName OID.
|
|
This OID is provided for informational purposes only."
|
|
::= { sPDUOutletConfigMSPgsEntry 4 }
|
|
|
|
sPDUOutletConfigMSPgsOutletCtrlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modeGracefulShutdown (1),
|
|
modeAnnunciator (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Control Mode of the outlet.
|
|
This OID is provided for informational purposes only."
|
|
::= { sPDUOutletConfigMSPgsEntry 5 }
|
|
|
|
sPDUOutletConfigMSPgsDeviceConfirm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
deviceConfirmNo (1),
|
|
deviceConfirmYes (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to deviceConfirmNo (1) cause the outlet to
|
|
NOT wait for device confirmation while performing graceful
|
|
operations.
|
|
|
|
Setting this OID to deviceConfirmYes (2) cause the outlet to
|
|
wait for device confirmation while performing graceful
|
|
operations."
|
|
::= { sPDUOutletConfigMSPgsEntry 6 }
|
|
|
|
sPDUOutletConfigMSPgsLowBattWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (-2..9999)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The amount of delay, in 6 second intervals, between
|
|
when the UPS goes on battery and the power down sequence for
|
|
the outlet is initiated.
|
|
|
|
Allowed values are:
|
|
|
|
-2 - Never initiate the power down sequence on low battery warning.
|
|
-1 - Initiate power down sequence based on remaining runtime.
|
|
1 - 9999 six second intervals (6 secs - 16hrs, 39 mins, 54 secs).
|
|
0 indicates to immediately initiate power down sequence on low
|
|
battery warning."
|
|
::= { sPDUOutletConfigMSPgsEntry 7 }
|
|
|
|
sPDUOutletConfigMSPgsLowBattMult OBJECT-TYPE
|
|
SYNTAX INTEGER (1..7)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" Only applicable if sPDUOutletConfigMSPgsLowBattWarning OID is
|
|
set to -1 (On Runtime Remaining).
|
|
|
|
Allows you to set the value to stagger the shutdown sequence of the outlets.
|
|
1 provides the longest delay (the outlet to shutoff first), and 7 would
|
|
provide the shortest delay (the outlet to shut off last).
|
|
|
|
Allowed values are:
|
|
1 - 7."
|
|
::= { sPDUOutletConfigMSPgsEntry 8 }
|
|
|
|
sPDUOutletConfigMSPgsRestartDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..9999)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The amount of delay, in 6 minute intervals, between
|
|
when the outlet is turned off and the outlet is turned back on
|
|
when performing a Graceful Shutdown.
|
|
|
|
Allowed values are:
|
|
|
|
-1 - Never turn outlet back on after a Graceful shutdown.
|
|
0 - 9999 six minute intervals (0 - 999hrs, 54 mins)."
|
|
::= { sPDUOutletConfigMSPgsEntry 9 }
|
|
|
|
sPDUOutletConfigMSPgsPowerOnDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..9999)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The amount of delay, in seconds, between the UPS entering
|
|
normal (on-line) state and the outlet being powered on.
|
|
|
|
Allowed values are:
|
|
|
|
-1 - Remain Off when the UPS enters the on-line state.
|
|
0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)."
|
|
::= { sPDUOutletConfigMSPgsEntry 10 }
|
|
|
|
|
|
sPDUOutletConfigMSPgsPowerOffDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (0..9999)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The amount of delay, in seconds, between when the server
|
|
shuts down and the outlet is powered off.
|
|
|
|
Allowed values are:
|
|
|
|
0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)."
|
|
::= { sPDUOutletConfigMSPgsEntry 11 }
|
|
|
|
sPDUOutletConfigMSPgsBattCapThresh OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The minimum battery capacity, as a percent (0-100%), required
|
|
of the UPS before an outlet will be allowed to power on.
|
|
|
|
Allowed values are:
|
|
|
|
0 - 100 percent."
|
|
::= { sPDUOutletConfigMSPgsEntry 12 }
|
|
|
|
sPDUOutletConfigMSPgsRebootDuration OBJECT-TYPE
|
|
SYNTAX INTEGER (0..9999)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The amount of delay, in seconds, from outlet off until
|
|
outlet on during a reboot.
|
|
|
|
Allowed values are:
|
|
|
|
0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)."
|
|
::= { sPDUOutletConfigMSPgsEntry 13 }
|
|
|
|
|
|
-- the sPDUOutConfigMSPannun group
|
|
|
|
sPDUOutletConfigMSPannunTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUOutletConfigMSPannunEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual outlets. The number of
|
|
entries is contained in the sPDUMasterStatusMSPOutletCount OID."
|
|
::= { sPDUOutletConfigMSPannun 1 }
|
|
|
|
sPDUOutletConfigMSPannunEntry OBJECT-TYPE
|
|
SYNTAX SPDUOutletConfigMSPannunEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to configure."
|
|
INDEX { sPDUOutletConfigMSPannunIndex, sPDUOutletConfigMSPannunOutletIndex }
|
|
::= { sPDUOutletConfigMSPannunTable 1 }
|
|
|
|
SPDUOutletConfigMSPannunEntry ::=
|
|
SEQUENCE {
|
|
sPDUOutletConfigMSPannunIndex INTEGER,
|
|
sPDUOutletConfigMSPannunName DisplayString,
|
|
sPDUOutletConfigMSPannunOutletIndex INTEGER,
|
|
sPDUOutletConfigMSPannunOutletName DisplayString,
|
|
sPDUOutletConfigMSPannunOutletCtrlMode INTEGER,
|
|
sPDUOutletConfigMSPannunInitialState INTEGER,
|
|
sPDUOutletConfigMSPannunAlarmActionDly INTEGER
|
|
}
|
|
|
|
sPDUOutletConfigMSPannunIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch plus."
|
|
::= { sPDUOutletConfigMSPannunEntry 1 }
|
|
|
|
sPDUOutletConfigMSPannunName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch plus. The maximum
|
|
value is 23 characters. The name is set by
|
|
using the sPDUMasterConfigMSPName OID."
|
|
::= { sPDUOutletConfigMSPannunEntry 2 }
|
|
|
|
sPDUOutletConfigMSPannunOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { sPDUOutletConfigMSPannunEntry 3 }
|
|
|
|
sPDUOutletConfigMSPannunOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum size is
|
|
23 characters. The name is set by using the
|
|
sPDUOutletConfigMSPallOutletName OID.
|
|
This OID is provided for informational purposes only."
|
|
::= { sPDUOutletConfigMSPannunEntry 4 }
|
|
|
|
sPDUOutletConfigMSPannunOutletCtrlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modeGracefulShutdown (1),
|
|
modeAnnunciator (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Control Mode of the outlet.
|
|
This OID is provided for informational purposes only."
|
|
::= { sPDUOutletConfigMSPannunEntry 5 }
|
|
|
|
sPDUOutletConfigMSPannunInitialState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
initialStateOff (1),
|
|
initialStateOn (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to initialStateOff (1) causes the outlet
|
|
to default to off when in the non-alarmed condition.
|
|
|
|
Setting this OID to initialStateOn (2) causes the outlet
|
|
to default to on when in the non-alarmed condition."
|
|
::= { sPDUOutletConfigMSPannunEntry 6 }
|
|
|
|
sPDUOutletConfigMSPannunAlarmActionDly OBJECT-TYPE
|
|
SYNTAX INTEGER (0..9999)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The amount of time, in seconds, that an enabled Measure-UPS
|
|
alarm must be asserted before an alarm condition is recognized.
|
|
|
|
Allowed values are:
|
|
|
|
0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)."
|
|
::= { sPDUOutletConfigMSPannunEntry 7 }
|
|
|
|
|
|
-- the sPDUOutConfigMSPmups group
|
|
|
|
sPDUOutletConfigMSPmupsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUOutletConfigMSPmupsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual outlets. The number of
|
|
entries is contained in the sPDUMasterStatusMSPOutletCount OID."
|
|
::= { sPDUOutletConfigMSPmups 1 }
|
|
|
|
sPDUOutletConfigMSPmupsEntry OBJECT-TYPE
|
|
SYNTAX SPDUOutletConfigMSPmupsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to configure."
|
|
INDEX { sPDUOutletConfigMSPmupsIndex, sPDUOutletConfigMSPmupsOutletIndex }
|
|
::= { sPDUOutletConfigMSPmupsTable 1 }
|
|
|
|
SPDUOutletConfigMSPmupsEntry ::=
|
|
SEQUENCE {
|
|
sPDUOutletConfigMSPmupsIndex INTEGER,
|
|
sPDUOutletConfigMSPmupsName DisplayString,
|
|
sPDUOutletConfigMSPmupsOutletIndex INTEGER,
|
|
sPDUOutletConfigMSPmupsOutletName DisplayString,
|
|
sPDUOutletConfigMSPmupsZone1 INTEGER,
|
|
sPDUOutletConfigMSPmupsZone2 INTEGER,
|
|
sPDUOutletConfigMSPmupsZone3 INTEGER,
|
|
sPDUOutletConfigMSPmupsZone4 INTEGER,
|
|
sPDUOutletConfigMSPmupsP1LowHum INTEGER,
|
|
sPDUOutletConfigMSPmupsP1HiHum INTEGER,
|
|
sPDUOutletConfigMSPmupsP1LowTemp INTEGER,
|
|
sPDUOutletConfigMSPmupsP1HiTemp INTEGER,
|
|
sPDUOutletConfigMSPmupsP2LowHum INTEGER,
|
|
sPDUOutletConfigMSPmupsP2HiHum INTEGER,
|
|
sPDUOutletConfigMSPmupsP2LowTemp INTEGER,
|
|
sPDUOutletConfigMSPmupsP2HiTemp INTEGER
|
|
}
|
|
|
|
sPDUOutletConfigMSPmupsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch plus."
|
|
::= { sPDUOutletConfigMSPmupsEntry 1 }
|
|
|
|
sPDUOutletConfigMSPmupsName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch plus. The maximum
|
|
value is 23 characters. The name is set by
|
|
using the sPDUMasterConfigMSPName OID."
|
|
::= { sPDUOutletConfigMSPmupsEntry 2 }
|
|
|
|
sPDUOutletConfigMSPmupsOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { sPDUOutletConfigMSPmupsEntry 3 }
|
|
|
|
sPDUOutletConfigMSPmupsOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum size is
|
|
23 characters. The name is set by using the
|
|
sPDUOutletConfigMSPallOutletName OID.
|
|
This OID is provided for informational purposes only."
|
|
::= { sPDUOutletConfigMSPmupsEntry 4 }
|
|
|
|
sPDUOutletConfigMSPmupsZone1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Zone 1 alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Zone 1 alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 5 }
|
|
|
|
sPDUOutletConfigMSPmupsZone2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Zone 2 alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Zone 2 alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 6 }
|
|
|
|
sPDUOutletConfigMSPmupsZone3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Zone 3 alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Zone 3 alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 7 }
|
|
|
|
sPDUOutletConfigMSPmupsZone4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Zone 4 alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Zone 4 alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 8 }
|
|
|
|
sPDUOutletConfigMSPmupsP1LowHum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Probe 1 low humidity alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Probe 1 low humidity alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 9 }
|
|
|
|
sPDUOutletConfigMSPmupsP1HiHum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Probe 1 high humidity alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Probe 1 high humidity alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 10 }
|
|
|
|
sPDUOutletConfigMSPmupsP1LowTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Probe 1 low temperature alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Probe 1 low temperature alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 11 }
|
|
|
|
sPDUOutletConfigMSPmupsP1HiTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Probe 1 high temperature alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Probe 1 high temperature alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 12 }
|
|
|
|
sPDUOutletConfigMSPmupsP2LowHum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Probe 2 low humidity alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Probe 2 low humidity alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 13 }
|
|
|
|
sPDUOutletConfigMSPmupsP2HiHum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Probe 2 high humidity alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Probe 2 high humidity alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 14 }
|
|
|
|
sPDUOutletConfigMSPmupsP2LowTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Probe 2 low temperature alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Probe 2 low temperature alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 15 }
|
|
|
|
sPDUOutletConfigMSPmupsP2HiTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableAlarm (1),
|
|
enableAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to disableAlarm (1) disables the
|
|
Probe 2 high temperature alarm for this outlet.
|
|
|
|
Setting this OID to enableAlarm (2) enables the
|
|
Probe 2 high temperature alarm for this outlet."
|
|
::= { sPDUOutletConfigMSPmupsEntry 16 }
|
|
|
|
-- the sPDUOutletStatusMSP group
|
|
|
|
sPDUOutletStatusMSPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPDUOutletStatusMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of individual outlets. The number of
|
|
entries is contained in the sPDUMasterStatusOutletCount OID."
|
|
::= { sPDUOutletStatusMSP 1 }
|
|
|
|
sPDUOutletStatusMSPEntry OBJECT-TYPE
|
|
SYNTAX SPDUOutletStatusMSPEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to gather status from."
|
|
INDEX { sPDUOutletStatusMSPIndex, sPDUOutletStatusMSPOutletIndex }
|
|
::= { sPDUOutletStatusMSPTable 1 }
|
|
|
|
SPDUOutletStatusMSPEntry ::=
|
|
SEQUENCE {
|
|
sPDUOutletStatusMSPIndex INTEGER,
|
|
sPDUOutletStatusMSPName DisplayString,
|
|
sPDUOutletStatusMSPOutletIndex INTEGER,
|
|
sPDUOutletStatusMSPOutletName DisplayString,
|
|
sPDUOutletStatusMSPOutletState INTEGER,
|
|
sPDUOutletStatusMSPCommandPending INTEGER,
|
|
sPDUOutletStatusMSPOutletCtrlMode INTEGER
|
|
}
|
|
|
|
sPDUOutletStatusMSPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the MasterSwitch MSP."
|
|
::= { sPDUOutletStatusMSPEntry 1 }
|
|
|
|
sPDUOutletStatusMSPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the MasterSwitch plus. The maximum
|
|
value is 23 characters. The name is set by
|
|
using the sPDUMasterConfigMSPName OID."
|
|
::= { sPDUOutletStatusMSPEntry 2 }
|
|
|
|
sPDUOutletStatusMSPOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { sPDUOutletStatusMSPEntry 3 }
|
|
|
|
sPDUOutletStatusMSPOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum size is
|
|
23 characters. The name is set by using the
|
|
sPDUOutletConfigMSPallOutletName OID.
|
|
This OID is provided for informational purposes only."
|
|
::= { sPDUOutletStatusMSPEntry 4 }
|
|
|
|
sPDUOutletStatusMSPOutletState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusMSPOn (1),
|
|
outletStatusMSPOff (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the outletStatusMSPOn (1) value will be returned.
|
|
If the outlet is off, the outletStatusMSPOff (2) value will be
|
|
returned. "
|
|
::= { sPDUOutletStatusMSPEntry 5 }
|
|
|
|
sPDUOutletStatusMSPCommandPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusMSPCommandPending (1),
|
|
outletStatusMSPNoCommandPending (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the command pending
|
|
state of the outlet. If a command is pending on the
|
|
outlet, the outletStatusMSPCommandPending (1) value
|
|
will be returned. If there is not a command pending
|
|
on the outlet, the outletStatusMSPNoCommandPending (2)
|
|
will be returned."
|
|
::= { sPDUOutletStatusMSPEntry 6 }
|
|
|
|
sPDUOutletStatusMSPOutletCtrlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modeGracefulShutdown (1),
|
|
modeAnnunciator (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Control Mode of the outlet.
|
|
This OID is provided for informational purposes only."
|
|
::= { sPDUOutletStatusMSPEntry 7 }
|
|
|
|
|
|
-- the rPDUIdent group
|
|
|
|
rPDUIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the Rack PDU.
|
|
The maximum string size is device dependent."
|
|
::= { rPDUIdent 1 }
|
|
|
|
rPDUIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Rack PDU.
|
|
This value is set at the factory."
|
|
::= { rPDUIdent 2 }
|
|
|
|
rPDUIdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An 8-byte ID string identifying the Rack PDU firmware revision.
|
|
This value is set at the factory."
|
|
::= { rPDUIdent 3 }
|
|
|
|
|
|
rPDUIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the Rack PDU was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory. The year 2000 will be
|
|
represented by 00."
|
|
::= { rPDUIdent 4 }
|
|
|
|
rPDUIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 10-character string identifying the model number of
|
|
the Rack PDU. This value is set at the factory."
|
|
::= { rPDUIdent 5 }
|
|
|
|
rPDUIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 12-character string identifying the serial number of
|
|
the Rack PDU. This value is set at the factory."
|
|
::= { rPDUIdent 6 }
|
|
|
|
rPDUIdentDeviceRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the electrical rating of the device in Amps."
|
|
|
|
::= { rPDUIdent 7 }
|
|
|
|
rPDUIdentDeviceNumOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the number of outlets contained in the device."
|
|
|
|
::= { rPDUIdent 8 }
|
|
|
|
rPDUIdentDeviceNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the number of phases supported by the device."
|
|
|
|
::= { rPDUIdent 9 }
|
|
|
|
rPDUIdentDeviceNumBreakers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the number of circuit breakers supported by the device.
|
|
This is the same as the number of banks of outlets.
|
|
0 will be returned if the unit has no phase breakers. "
|
|
|
|
::= { rPDUIdent 10 }
|
|
|
|
rPDUIdentDeviceBreakerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return rating of the circuit breakers
|
|
on the device in Amps if it has any."
|
|
|
|
::= { rPDUIdent 11 }
|
|
|
|
rPDUIdentDeviceOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
orientHorizontal (1),
|
|
orientVertical (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the intended physical orientation of the device.
|
|
|
|
OrientHorizonatal(1) indicates Horizontal.
|
|
OrientVertical(2) indicates Vertical."
|
|
|
|
::= { rPDUIdent 12 }
|
|
|
|
rPDUIdentDeviceOutletLayout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
seqPhaseToNeutral (1),
|
|
seqPhaseToPhase (2),
|
|
seqPhToNeu21PhToPh (3),
|
|
seqPhToPhGrouped (4),
|
|
seqPhToNGrouped (5),
|
|
seqPToN1516PToPGrouped (6),
|
|
seqPhToPh2xGrouped (7),
|
|
seqPhToN2xGrouped (8),
|
|
seqNotApplicable (9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return outlet layout for the device.
|
|
|
|
seqPhaseToNeutral(1) indicates outlet layout as follows:
|
|
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
|
|
|
|
seqPhaseToPhase(2) indicates outlet layout as follows:
|
|
1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,...
|
|
|
|
seqPhToNeu21PhToPh(3) indicates outlet layout as follows:
|
|
1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,...
|
|
|
|
seqPhToPhGrouped(4) indicates outlet layout as follows:
|
|
For AP8xxx SKU's Group 1:1-2, Group 2:2-3, Group 3:3-1.
|
|
For AP7xxx SKU's Group 1:3-1. Group 2:2-3, Group 3:1-2.
|
|
|
|
seqPhToNGrouped(5) indicates outlet layout as follows:
|
|
This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N.
|
|
|
|
seqPToN1516PToPGrouped(6) indicates outlet layout as follows:
|
|
This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2,
|
|
Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1.
|
|
|
|
seqPhToPh2xGrouped(7) indicates outlet layout as follows:
|
|
This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3,
|
|
Group 4:2-3, Group 5:3-1, Group 6:3-1.
|
|
|
|
seqPhToN2xGrouped(8) indicates outlet layout as follows:
|
|
This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N,
|
|
Group 4:2-N, Group 5:3-N, Group 6:3-N.
|
|
|
|
seqNotApplicable(9):
|
|
Outlet layout does not affect any of the user interfaces.
|
|
These SKUs may report seqNotApplicable(9) if there is
|
|
not an exact outlet layout match available."
|
|
::= { rPDUIdent 13 }
|
|
|
|
rPDUIdentDeviceDisplayOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
displayNormal (1),
|
|
displayReverse (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the intended physical orientation of the Seven-Segment Display.
|
|
|
|
Normal(1) indicates Normal.
|
|
Reverse(2)indicates Upside-Down."
|
|
|
|
::= { rPDUIdent 14 }
|
|
|
|
|
|
rPDUIdentDeviceLinetoLineVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting/Setting this OID will return/set the Line to Line Voltage.
|
|
This OID defaults to the nominal input line voltage in volts AC.
|
|
This setting is used to calculate total power and must be configured for best accuracy.
|
|
This OID does not apply to AP86XX, AP88XX, or AP89XX SKUs.
|
|
|
|
The valid range is between 0V to 440V"
|
|
::= { rPDUIdent 15 }
|
|
|
|
rPDUIdentDevicePowerWatts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Power in Watts."
|
|
|
|
::= { rPDUIdent 16 }
|
|
|
|
rPDUIdentDevicePowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting/setting this OID will return/set the
|
|
Power Factor in thousanths (1000 is power factor of 1).
|
|
For AP8XXX SKUs, this OID is read-only
|
|
|
|
Valid range is from 0 to 1000."
|
|
::= { rPDUIdent 17 }
|
|
|
|
rPDUIdentDevicePowerVA OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Power in VA."
|
|
|
|
::= { rPDUIdent 18 }
|
|
|
|
rPDUIdentDeviceLinetoNeutralVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting/Setting this OID will return/set the Line to Neutral Voltage.
|
|
This OID defaults to the nominal line to neutral voltage in volts AC.
|
|
This setting is used to calculate total power and must be configured for best accuracy.
|
|
This OID applies only to AP7823. For all other models, the OID is fixed at 0.
|
|
|
|
The valid range is between 0V to 440V."
|
|
|
|
::= { rPDUIdent 19 }
|
|
|
|
-- the rPDULoadDevice group
|
|
|
|
rPDULoadDevMaxPhaseLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the maximum rated power
|
|
that each phase of the Rack PDU can provide. It is
|
|
represented in Amps.
|
|
|
|
0 will be returned if the unit is banked."
|
|
::= { rPDULoadDevice 1 }
|
|
|
|
rPDULoadDevNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of phases available with this Rack PDU."
|
|
::= { rPDULoadDevice 2 }
|
|
|
|
rPDULoadDevMaxBankLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the maximum rated power
|
|
that a bank of the Rack PDU can provide. It is
|
|
represented in Amps.
|
|
|
|
0 will be returned if the device does not have any banks."
|
|
|
|
::= { rPDULoadDevice 3 }
|
|
|
|
rPDULoadDevNumBanks OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of banks of outlets available with this Rack PDU.
|
|
A bank of outlets has a unique circuit breaker for a subset
|
|
of the total number of outlets on the rPDU.
|
|
|
|
0 will be returned if the unit has no banks."
|
|
::= { rPDULoadDevice 4 }
|
|
|
|
rPDULoadDevBankTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Bank Table."
|
|
::= { rPDULoadDevice 5 }
|
|
|
|
|
|
rPDULoadDevBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDULoadDevBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the Bank Max Load in the Rack PDU."
|
|
|
|
::= { rPDULoadDevice 6 }
|
|
|
|
rPDULoadDevBankEntry OBJECT-TYPE
|
|
SYNTAX RPDULoadDevBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU Banks Access."
|
|
INDEX { rPDULoadDevBankIndex}
|
|
::= { rPDULoadDevBankTable 1 }
|
|
|
|
RPDULoadDevBankEntry ::=
|
|
SEQUENCE {
|
|
rPDULoadDevBankIndex INTEGER,
|
|
rPDULoadDevBankNumber INTEGER,
|
|
rPDULoadDevBankMaxLoad INTEGER
|
|
}
|
|
|
|
rPDULoadDevBankIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU bank entry."
|
|
::= { rPDULoadDevBankEntry 1 }
|
|
|
|
rPDULoadDevBankNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bank number."
|
|
|
|
::= { rPDULoadDevBankEntry 2 }
|
|
|
|
rPDULoadDevBankMaxLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the maximum rated power
|
|
that each bank of the Rack PDU can provide. It is
|
|
represented in Amps."
|
|
|
|
::= { rPDULoadDevBankEntry 3 }
|
|
|
|
rPDULoadDevMaxOutletTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Outlet Table."
|
|
::= { rPDULoadDevice 7 }
|
|
|
|
|
|
rPDULoadDevMaxOutletTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDULoadDevMaxOutletEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the Max Outlet Load in an Outlet Monitored Rack PDU."
|
|
::= { rPDULoadDevice 8 }
|
|
|
|
rPDULoadDevMaxOutletEntry OBJECT-TYPE
|
|
SYNTAX RPDULoadDevMaxOutletEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to Max Outlet Load of an Outlet Monitored Rack PDU"
|
|
INDEX { rPDULoadDevOutletIndex}
|
|
::= { rPDULoadDevMaxOutletTable 1 }
|
|
|
|
RPDULoadDevMaxOutletEntry ::=
|
|
SEQUENCE {
|
|
rPDULoadDevOutletIndex INTEGER,
|
|
rPDULoadDevOutletNumber INTEGER,
|
|
rPDULoadDevMaxOutletLoad INTEGER
|
|
}
|
|
|
|
rPDULoadDevOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Outlet Monitored Rack PDU Max Outlet Load entry."
|
|
::= { rPDULoadDevMaxOutletEntry 1 }
|
|
|
|
rPDULoadDevOutletNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Outlet number."
|
|
::= { rPDULoadDevMaxOutletEntry 2 }
|
|
|
|
|
|
rPDULoadDevMaxOutletLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the maximum rated power
|
|
that each Outlet of an Outlet Monitored Rack PDU can provide. It is
|
|
represented in Amps. "
|
|
::= { rPDULoadDevMaxOutletEntry 3 }
|
|
|
|
|
|
|
|
-- the rPDULoadPhaseConfig group
|
|
|
|
rPDULoadPhaseConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDULoadPhaseConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of each Rack PDU phase.
|
|
The number of entries is contained in the
|
|
rPDULoadDevNumPhases OID."
|
|
::= { rPDULoadPhaseConfig 1 }
|
|
|
|
rPDULoadPhaseConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDULoadPhaseConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU phase to configure."
|
|
INDEX { rPDULoadPhaseConfigIndex}
|
|
::= { rPDULoadPhaseConfigTable 1 }
|
|
|
|
RPDULoadPhaseConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDULoadPhaseConfigIndex INTEGER,
|
|
rPDULoadPhaseConfigLowLoadThreshold INTEGER,
|
|
rPDULoadPhaseConfigNearOverloadThreshold INTEGER,
|
|
rPDULoadPhaseConfigOverloadThreshold INTEGER,
|
|
rPDULoadPhaseConfigAlarm INTEGER
|
|
}
|
|
|
|
rPDULoadPhaseConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase entry."
|
|
::= { rPDULoadPhaseConfigEntry 1 }
|
|
|
|
rPDULoadPhaseConfigLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing a low consumption condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is less than the threshold value.
|
|
|
|
A threshold value of 0 Amps effectively disables this
|
|
warning.
|
|
|
|
Maximum value must be less than the value returned
|
|
by the rPDULoadPhaseConfigNearOverloadThreshold OID."
|
|
::= { rPDULoadPhaseConfigEntry 2 }
|
|
|
|
rPDULoadPhaseConfigNearOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value.
|
|
|
|
Minimum value must be greater than the value returned by
|
|
the rPDULoadPhaseConfigLowLoadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the rPDULoadPhaseConfigOverloadThreshold OID."
|
|
::= { rPDULoadPhaseConfigEntry 3 }
|
|
|
|
rPDULoadPhaseConfigOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load has entered an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value.
|
|
|
|
Minimum value must be greater than or equal to the value
|
|
returned by the rPDULoadPhaseConfigNearOverloadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the rPDULoadDevMaxPhaseLoad OID."
|
|
::= { rPDULoadPhaseConfigEntry 4 }
|
|
|
|
|
|
rPDULoadPhaseConfigAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noLoadAlarm (1),
|
|
underCurrentAlarm (2),
|
|
nearOverCurrentAlarm (3),
|
|
overCurrentAlarm (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the current Phase Alarm."
|
|
::= { rPDULoadPhaseConfigEntry 5 }
|
|
|
|
|
|
|
|
|
|
|
|
-- the rPDULoadStatus group
|
|
|
|
rPDULoadStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDULoadStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of each Rack PDU phase/bank.
|
|
The number of entries is calculated by adding
|
|
the number of phases (rPDULoadDevNumPhases OID) and
|
|
the number of banks of outlets (rPDULoadDevNumBanks)
|
|
Number of entries = #phases + #banks.
|
|
NOTE: If a device has phase and bank information, all phase information
|
|
shall precede the bank information. If a device has total information,
|
|
it shall precede both the bank and the phase information."
|
|
::= { rPDULoadStatus 1 }
|
|
|
|
rPDULoadStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDULoadStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU phase/bank to gather status from."
|
|
INDEX { rPDULoadStatusIndex}
|
|
::= { rPDULoadStatusTable 1 }
|
|
|
|
RPDULoadStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDULoadStatusIndex INTEGER,
|
|
rPDULoadStatusLoad Gauge,
|
|
rPDULoadStatusLoadState INTEGER,
|
|
rPDULoadStatusPhaseNumber INTEGER,
|
|
rPDULoadStatusBankNumber INTEGER
|
|
}
|
|
|
|
rPDULoadStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase/bank entry. All phase information will precede
|
|
any bank information"
|
|
::= { rPDULoadStatusEntry 1 }
|
|
|
|
rPDULoadStatusLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase/bank load measured
|
|
in tenths of Amps."
|
|
::= { rPDULoadStatusEntry 2 }
|
|
|
|
rPDULoadStatusLoadState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phaseLoadNormal (1),
|
|
phaseLoadLow (2),
|
|
phaseLoadNearOverload (3),
|
|
phaseLoadOverload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase/bank load state.
|
|
|
|
phaseLoadNormal(1) indicates that the phase/bank is
|
|
operating properly within the rPDULoadConfigLowLoadThreshold
|
|
and rPDULoadConfigNearOverloadThreshold OID values.
|
|
|
|
phaseLoadLow(2) indicates that the phase/bank load has
|
|
dropped below the rPDULoadConfigLowLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
phaseLoadNearOverload(3) indicates that the phase/bank load
|
|
is greater than or equal to the
|
|
rPDULoadConfigNearOverloadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
phaseLoadOverload(4) indicates that the phase/bank load is
|
|
greater than or equal to the rPDULoadConfigOverloadThreshold
|
|
OID value.
|
|
An SNMP trap will occur when this state is entered or cleared."
|
|
::= { rPDULoadStatusEntry 3 }
|
|
|
|
rPDULoadStatusPhaseNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase number to which this record refers."
|
|
::= { rPDULoadStatusEntry 4 }
|
|
|
|
rPDULoadStatusBankNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank number to which this record refers. A value of 0 will be returned if
|
|
any bank is not present or if it is phase related."
|
|
::= { rPDULoadStatusEntry 5 }
|
|
|
|
|
|
-- the rPDULoadBankConfig group
|
|
|
|
rPDULoadBankConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDULoadBankConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of each Rack PDU bank.
|
|
The number of entries is contained in the
|
|
rPDULoadDevNumBanks OID."
|
|
::= { rPDULoadBankConfig 1 }
|
|
|
|
rPDULoadBankConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDULoadBankConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU bank to configure."
|
|
INDEX { rPDULoadBankConfigIndex}
|
|
::= { rPDULoadBankConfigTable 1 }
|
|
|
|
RPDULoadBankConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDULoadBankConfigIndex INTEGER,
|
|
rPDULoadBankConfigLowLoadThreshold INTEGER,
|
|
rPDULoadBankConfigNearOverloadThreshold INTEGER,
|
|
rPDULoadBankConfigOverloadThreshold INTEGER,
|
|
rPDULoadBankConfigAlarm INTEGER
|
|
}
|
|
|
|
rPDULoadBankConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU bank entry."
|
|
::= { rPDULoadBankConfigEntry 1 }
|
|
|
|
rPDULoadBankConfigLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing a low consumption condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is less than the threshold value.
|
|
|
|
A threshold value of 0 Amps effectively disables this
|
|
warning.
|
|
|
|
Maximum value must be less than the value returned
|
|
by the rPDULoadBankConfigNearOverloadThreshold OID."
|
|
|
|
::= { rPDULoadBankConfigEntry 2 }
|
|
|
|
rPDULoadBankConfigNearOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value.
|
|
|
|
Minimum value must be greater than the value returned by
|
|
the rPDULoadBankConfigLowLoadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the rPDULoadBankConfigOverloadThreshold OID."
|
|
|
|
::= { rPDULoadBankConfigEntry 3 }
|
|
|
|
rPDULoadBankConfigOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load has entered an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value.
|
|
|
|
Minimum value must be greater than or equal to the value
|
|
returned by the rPDULoadBankConfigNearOverloadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the rPDULoadDevMaxBankLoad OID."
|
|
|
|
::= { rPDULoadBankConfigEntry 4 }
|
|
|
|
rPDULoadBankConfigAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noLoadAlarm (1),
|
|
underCurrentAlarm (2),
|
|
nearOverCurrentAlarm (3),
|
|
overCurrentAlarm (4)
|
|
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" Getting this OID will return the current Bank Alarm."
|
|
::= { rPDULoadBankConfigEntry 5 }
|
|
|
|
|
|
-- the rPDUOutletDevice group
|
|
|
|
rPDUOutletDevCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noCommandAll (1),
|
|
immediateAllOn (2),
|
|
immediateAllOff (3),
|
|
immediateAllReboot (4),
|
|
delayedAllOn (5),
|
|
delayedAllOff (6),
|
|
delayedAllReboot (7),
|
|
cancelAllPendingCommands (8)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to immediateAllOn (2) will turn all outlets
|
|
on immediately.
|
|
|
|
Setting this OID to immediateAllOff (3) will turn all outlets
|
|
off immediately.
|
|
|
|
Setting this OID to immediateAllReboot (4) will reboot all outlets
|
|
immediately.
|
|
|
|
Setting this OID to delayedAllOn (5) will turn all outlets on as
|
|
defined by each outlet's rPDUOutletConfigPowerOnTime OID value.
|
|
|
|
Setting this OID to delayedAllOff (6) will turn all outlets
|
|
off as defined by each outlet's rPDUOutletConfigPowerOffTime OID value.
|
|
|
|
Setting this OID to delayedAllReboot (7) will cause a
|
|
delayedAllOff command to be performed. Once all outlets are off,
|
|
the Switched Rack PDU will then delay the largest
|
|
rPDUOutletConfigRebootDuration OID time, and then perform a
|
|
delayedAllOn command.
|
|
|
|
Setting this OID to cancelAllPendingCommands (8) will cause all pending
|
|
commands on the Switched Rack PDU to be canceled.
|
|
|
|
Getting this OID will return the noCommandAll (1) value."
|
|
::= { rPDUOutletDevice 1 }
|
|
|
|
rPDUOutletDevColdstartDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of delay, in seconds, between when
|
|
power is provided to the Switched Rack PDU and
|
|
when the Switched Rack PDU provides basic master
|
|
power to the outlets.
|
|
|
|
Allowed values are:
|
|
|
|
-1 - never apply power automatically.
|
|
0 - apply power immediately.
|
|
1 to 300 - delay up to 300 seconds (5 minutes)."
|
|
::= { rPDUOutletDevice 2 }
|
|
|
|
rPDUOutletDevNumCntrlOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of controlled outlets on this Switched Rack PDU."
|
|
::= { rPDUOutletDevice 3 }
|
|
|
|
rPDUOutletDevNumTotalOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of outlets on this Rack PDU."
|
|
::= { rPDUOutletDevice 4 }
|
|
|
|
rPDUOutletDevMonitoredOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of monitored outlets on this Rack PDU."
|
|
::= { rPDUOutletDevice 5 }
|
|
|
|
|
|
-- the rPDUOutletPhase group
|
|
|
|
rPDUOutletPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUOutletPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for management of outlets on a per phase basis."
|
|
::= { rPDUOutletPhase 1 }
|
|
|
|
rPDUOutletPhaseEntry OBJECT-TYPE
|
|
SYNTAX RPDUOutletPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase to manage."
|
|
INDEX { rPDUOutletPhaseIndex}
|
|
::= { rPDUOutletPhaseTable 1 }
|
|
|
|
RPDUOutletPhaseEntry ::=
|
|
SEQUENCE {
|
|
rPDUOutletPhaseIndex INTEGER,
|
|
rPDUOutletPhaseOverloadRestriction INTEGER
|
|
}
|
|
|
|
rPDUOutletPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Switched Rack PDU phase entry."
|
|
::= { rPDUOutletPhaseEntry 1 }
|
|
|
|
rPDUOutletPhaseOverloadRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysAllowTurnON (1),
|
|
restrictOnNearOverload (2),
|
|
restrictOnOverload (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of a Switched Rack PDU
|
|
phase when an overload condition is possible and
|
|
additional outlets are requested to be turned on.
|
|
|
|
Setting this OID to alwaysAllowTurnON (1) will always allow
|
|
the outlets on the corresponding phase to turn on.
|
|
|
|
Setting this OID to restrictOnNearOverload (2) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
rPDULoadConfigNearOverloadThreshold OID is exceeded.
|
|
|
|
Setting this OID to restrictOnOverload (3) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
rPDULoadConfigOverloadThreshold OID is exceeded."
|
|
::= { rPDUOutletPhaseEntry 2 }
|
|
|
|
|
|
-- the rPDUOutletControl group
|
|
|
|
rPDUOutletControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUOutletControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of the individual outlets.
|
|
The number of entries is contained in the
|
|
rPDUOutletDevNumCntrlOutlets OID."
|
|
::= { rPDUOutletControl 1 }
|
|
|
|
rPDUOutletControlEntry OBJECT-TYPE
|
|
SYNTAX RPDUOutletControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet to control."
|
|
INDEX { rPDUOutletControlIndex}
|
|
::= { rPDUOutletControlTable 1 }
|
|
|
|
RPDUOutletControlEntry ::=
|
|
SEQUENCE {
|
|
rPDUOutletControlIndex INTEGER,
|
|
rPDUOutletControlOutletName DisplayString,
|
|
rPDUOutletControlOutletPhase INTEGER,
|
|
rPDUOutletControlOutletCommand INTEGER,
|
|
rPDUOutletControlOutletBank INTEGER
|
|
}
|
|
|
|
rPDUOutletControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { rPDUOutletControlEntry 1 }
|
|
|
|
rPDUOutletControlOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum string size is device dependent.
|
|
An error will be returned if the set request exceeds the max size.
|
|
This OID is provided for informational purposes only."
|
|
::= { rPDUOutletControlEntry 2 }
|
|
|
|
rPDUOutletControlOutletPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3),
|
|
phase1-2 (4),
|
|
phase2-3 (5),
|
|
phase3-1 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase/s associated with this outlet.
|
|
|
|
For single phase devices, this object will always
|
|
return phase1(1).
|
|
|
|
For 3-phase devices, this object will return phase1 (1),
|
|
phase2 (2), or phase3 (3) for outlets tied to a single
|
|
phase. For outlets tied to two phases, this object will
|
|
return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
|
|
phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
|
|
::= { rPDUOutletControlEntry 3 }
|
|
|
|
rPDUOutletControlOutletCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
immediateOn (1),
|
|
immediateOff (2),
|
|
immediateReboot (3),
|
|
delayedOn (4),
|
|
delayedOff (5),
|
|
delayedReboot (6),
|
|
cancelPendingCommand (7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the immediateOn (1) value will be returned.
|
|
If the outlet is off, the immediateOff (2) value will be
|
|
returned.
|
|
|
|
|
|
Setting this variable to immediateOn (1) will immediately turn
|
|
the outlet on.
|
|
|
|
Setting this variable to immediateOff (2) will immediately turn
|
|
the outlet off.
|
|
|
|
Setting this variable to immediateReboot (3) will immediately
|
|
reboot the outlet.
|
|
|
|
Setting this variable to delayedOn (4) will turn the outlet on
|
|
after the rPDUOutletConfigPowerOnTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedOff (5) will turn the outlet off
|
|
after the rPDUOutletConfigPowerOffTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedReboot (6) will cause the
|
|
Switched Rack PDU to perform a delayedOff command, wait the
|
|
rPDUOutletConfigRebootDuration OID time, and then perform a
|
|
delayedOn command.
|
|
|
|
Setting this variable to cancelPendingCommand (7) will cause any
|
|
pending command to this outlet to be canceled."
|
|
|
|
::= { rPDUOutletControlEntry 4 }
|
|
|
|
rPDUOutletControlOutletBank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank associated with this outlet."
|
|
::= { rPDUOutletControlEntry 5 }
|
|
|
|
|
|
-- the rPDUOutletConfig group
|
|
|
|
rPDUOutletConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual outlets. The number of
|
|
entries is contained in the rPDUOutletDevNumCntrlOutlets OID."
|
|
::= { rPDUOutletConfig 1 }
|
|
|
|
rPDUOutletConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDUOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet to configure."
|
|
INDEX { rPDUOutletConfigIndex}
|
|
::= { rPDUOutletConfigTable 1 }
|
|
|
|
RPDUOutletConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDUOutletConfigIndex INTEGER,
|
|
rPDUOutletConfigOutletName DisplayString,
|
|
rPDUOutletConfigOutletPhase INTEGER,
|
|
rPDUOutletConfigPowerOnTime INTEGER,
|
|
rPDUOutletConfigPowerOffTime INTEGER,
|
|
rPDUOutletConfigRebootDuration INTEGER,
|
|
rPDUOutletConfigOutletBank INTEGER
|
|
}
|
|
|
|
rPDUOutletConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { rPDUOutletConfigEntry 1 }
|
|
|
|
rPDUOutletConfigOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum string size is device dependent.
|
|
An error will be returned if the set request exceeds the max size."
|
|
::= { rPDUOutletConfigEntry 2 }
|
|
|
|
rPDUOutletConfigOutletPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3),
|
|
phase1-2 (4),
|
|
phase2-3 (5),
|
|
phase3-1 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase/s associated with this outlet.
|
|
|
|
For single phase devices, this object will always
|
|
return phase1(1).
|
|
|
|
For 3-phase devices, this object will return phase1 (1),
|
|
phase2 (2), or phase3 (3) for outlets tied to a single
|
|
phase. For outlets tied to two phases, this object will
|
|
return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
|
|
phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
|
|
::= { rPDUOutletConfigEntry 3 }
|
|
|
|
rPDUOutletConfigPowerOnTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering on at coldstart or when a command that requires
|
|
a turn-on delay is issued.
|
|
|
|
Allowed values are:
|
|
|
|
-1 - never power on.
|
|
0 - power on immediately.
|
|
1 to 7200 - power on up to 7200 seconds after being
|
|
commanded."
|
|
::= { rPDUOutletConfigEntry 4 }
|
|
|
|
rPDUOutletConfigPowerOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering off when a command that requires
|
|
a turn-off delay is issued.
|
|
|
|
Allowed values are:
|
|
|
|
-1 - never power off.
|
|
0 - power off immediately.
|
|
1 to 7200 - power off up to 7200 seconds after being
|
|
commanded."
|
|
::= { rPDUOutletConfigEntry 5 }
|
|
|
|
rPDUOutletConfigRebootDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"During a reboot sequence, power is turned off and then
|
|
back on. This OID defines the amount of time to wait,
|
|
in seconds, after turning the power off, at the start
|
|
of the sequence, before turning power back on, at the
|
|
end of the reboot sequence.
|
|
|
|
Allowed range is any value between 5 and 60 seconds (1 minute)."
|
|
::= { rPDUOutletConfigEntry 6 }
|
|
|
|
rPDUOutletConfigOutletBank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank associated with this outlet."
|
|
::= { rPDUOutletConfigEntry 7 }
|
|
|
|
-- Monitored Outlets table
|
|
|
|
rPDUOutletConfigMonitoredTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Outlet Config Monitored Table"
|
|
::= { rPDUOutletConfig 2 }
|
|
|
|
|
|
rPDUOutletConfigMonitoredTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUOutletConfigMonitoredEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting/setting of outlet thresholds of an Outlet Monitored Rack PDU."
|
|
::= { rPDUOutletConfig 3 }
|
|
|
|
rPDUOutletConfigMonitoredEntry OBJECT-TYPE
|
|
SYNTAX RPDUOutletConfigMonitoredEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to Monitored Outlet entries"
|
|
INDEX { rPDUOutletConfigMonitoredIndex }
|
|
::= { rPDUOutletConfigMonitoredTable 1 }
|
|
|
|
RPDUOutletConfigMonitoredEntry ::=
|
|
SEQUENCE {
|
|
rPDUOutletConfigMonitoredIndex INTEGER,
|
|
rPDUOutletConfigMonitoredName DisplayString,
|
|
rPDUOutletConfigMonitoredNumber INTEGER,
|
|
rPDUOutletConfigMonitoredLowLoadThreshold INTEGER,
|
|
rPDUOutletConfigMonitoredNearOverloadThreshold INTEGER,
|
|
rPDUOutletConfigMonitoredOverloadThreshold INTEGER
|
|
}
|
|
|
|
rPDUOutletConfigMonitoredIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the RACK PDU Phase entry."
|
|
::= { rPDUOutletConfigMonitoredEntry 1 }
|
|
|
|
rPDUOutletConfigMonitoredName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the Monitored Outlet. The maximum string size is device dependent.
|
|
An error will be returned if the set request exceeds the max size."
|
|
::= { rPDUOutletConfigMonitoredEntry 2 }
|
|
|
|
rPDUOutletConfigMonitoredNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet number of an Outlet Monitored RACK PDU."
|
|
::= { rPDUOutletConfigMonitoredEntry 3 }
|
|
|
|
|
|
rPDUOutletConfigMonitoredLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing a low consumption condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is less than the threshold value.
|
|
|
|
A threshold value of 0 Amps effectively disables this
|
|
warning.
|
|
|
|
Maximum value must be less than the value returned
|
|
by the rPDUOutletConfigMonitoredNearOverloadThreshold OID.
|
|
|
|
0 will be returned if the unit is not Outlet Monitored Rack PDU."
|
|
::= { rPDUOutletConfigMonitoredEntry 4 }
|
|
|
|
rPDUOutletConfigMonitoredNearOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value.
|
|
|
|
Minimum value must be greater than the value returned by
|
|
the rPDUOutletConfigMonitoredLowLoadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the rPDUOutletConfigMonitoredOverloadThreshold OID.
|
|
|
|
0 will be returned if the unit is not Outlet Monitored Rack PDU."
|
|
::= { rPDUOutletConfigMonitoredEntry 5 }
|
|
|
|
rPDUOutletConfigMonitoredOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load has entered an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value.
|
|
|
|
Minimum value must be greater than or equal to the value
|
|
returned by the rPDUOutletConfigMonitoredNearOverloadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the rPDULoadDevMaxOutletLoad OID.
|
|
|
|
0 will be returned if the unit is not Outlet Monitored Rack PDU."
|
|
::= { rPDUOutletConfigMonitoredEntry 6 }
|
|
|
|
|
|
|
|
|
|
-- the rPDUOutletStatus group
|
|
|
|
rPDUOutletStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUOutletStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of individual outlets. The number of
|
|
entries is contained in the rPDUOutletDevNumCntrlOutlets OID or
|
|
rPDUOutletDevMonitoredOutlets OID."
|
|
::= { rPDUOutletStatus 1 }
|
|
|
|
rPDUOutletStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDUOutletStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet to gather status from."
|
|
INDEX { rPDUOutletStatusIndex}
|
|
::= { rPDUOutletStatusTable 1 }
|
|
|
|
RPDUOutletStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDUOutletStatusIndex INTEGER,
|
|
rPDUOutletStatusOutletName DisplayString,
|
|
rPDUOutletStatusOutletPhase INTEGER,
|
|
rPDUOutletStatusOutletState INTEGER,
|
|
rPDUOutletStatusCommandPending INTEGER,
|
|
rPDUOutletStatusOutletBank INTEGER,
|
|
rPDUOutletStatusLoad Gauge
|
|
}
|
|
|
|
rPDUOutletStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { rPDUOutletStatusEntry 1 }
|
|
|
|
rPDUOutletStatusOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum string size is device dependent.
|
|
This OID is provided for informational purposes only."
|
|
::= { rPDUOutletStatusEntry 2 }
|
|
|
|
rPDUOutletStatusOutletPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3),
|
|
phase1-2 (4),
|
|
phase2-3 (5),
|
|
phase3-1 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase/s associated with this outlet.
|
|
|
|
For single phase devices, this object will always
|
|
return phase1(1).
|
|
|
|
For 3-phase devices, this object will return phase1 (1),
|
|
phase2 (2), or phase3 (3) for outlets tied to a single
|
|
phase. For outlets tied to two phases, this object will
|
|
return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
|
|
phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
|
|
::= { rPDUOutletStatusEntry 3 }
|
|
|
|
rPDUOutletStatusOutletState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusOn (1),
|
|
outletStatusOff (2)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the outletStatusOn (1) value will be returned.
|
|
If the outlet is off, the outletStatusOff (2) value will be
|
|
returned."
|
|
::= { rPDUOutletStatusEntry 4 }
|
|
|
|
rPDUOutletStatusCommandPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusCommandPending (1),
|
|
outletStatusNoCommandPending (2)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the command pending
|
|
state of the outlet. If a command is pending on the
|
|
outlet, the outletStatusCommandPending (1) value
|
|
will be returned. If there is not a command pending
|
|
on the outlet, the outletStatusNoCommandPending (2)
|
|
will be returned."
|
|
::= { rPDUOutletStatusEntry 5 }
|
|
|
|
rPDUOutletStatusOutletBank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank associated with this outlet."
|
|
::= { rPDUOutletStatusEntry 6 }
|
|
|
|
rPDUOutletStatusLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the measured Outlet load for
|
|
an Outlet Monitored Rack PDU in tenths of Amps. For other
|
|
models this OID is not supported."
|
|
::= { rPDUOutletStatusEntry 7 }
|
|
|
|
|
|
-- the rPDUOutletBank group
|
|
|
|
rPDUOutletBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUOutletBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for management of outlets on a per bank basis."
|
|
::= { rPDUOutletBank 1 }
|
|
|
|
rPDUOutletBankEntry OBJECT-TYPE
|
|
SYNTAX RPDUOutletBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank to manage."
|
|
INDEX { rPDUOutletBankIndex}
|
|
::= { rPDUOutletBankTable 1 }
|
|
|
|
RPDUOutletBankEntry ::=
|
|
SEQUENCE {
|
|
rPDUOutletBankIndex INTEGER,
|
|
rPDUOutletBankOverloadRestriction INTEGER
|
|
}
|
|
|
|
rPDUOutletBankIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Switched Rack PDU bank entry."
|
|
::= { rPDUOutletBankEntry 1 }
|
|
|
|
rPDUOutletBankOverloadRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysAllowTurnON (1),
|
|
restrictOnNearOverload (2),
|
|
restrictOnOverload (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of a Switched Rack PDU
|
|
bank when an overload condition is possible and
|
|
additional outlets are requested to be turned on.
|
|
|
|
Setting this OID to alwaysAllowTurnON (1) will always allow
|
|
the outlets on the corresponding bank to turn on.
|
|
|
|
Setting this OID to restrictOnNearOverload (2) will not allow
|
|
outlets on the corresponding bank to turn on if the
|
|
rPDULoadBankConfigNearOverloadThreshold OID is exceeded.
|
|
|
|
Setting this OID to restrictOnOverload (3) will not allow
|
|
outlets on the corresponding bank to turn on if the
|
|
rPDULoadBankConfigOverloadThreshold OID is exceeded."
|
|
::= { rPDUOutletBankEntry 2 }
|
|
|
|
-- the rPDUPowerSupplyDevice group
|
|
|
|
rPDUPowerSupply1Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerSupplyOneOk (1),
|
|
powerSupplyOneFailed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return powerSupply1Ok(1) if power
|
|
supply 1 is functioning normally. If not functioning normally,
|
|
this OID will return powerSupply1Failed(2)."
|
|
::= { rPDUPowerSupplyDevice 1 }
|
|
|
|
rPDUPowerSupply2Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerSupplyTwoOk (1),
|
|
powerSupplyTwoFailed (2),
|
|
powerSupplyTwoNotPresent (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return powerSupply2Ok(1) if power
|
|
supply 2 is functioning normally. If not functioning normally,
|
|
this OID will return powerSupply2Failed(2).
|
|
|
|
Metered Rack PDUs do not have a redundant powersupply."
|
|
|
|
::= { rPDUPowerSupplyDevice 2 }
|
|
|
|
|
|
|
|
rPDUPowerSupplyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allAvailablePowerSuppliesOK (1),
|
|
powerSupplyOneFailed (2),
|
|
powerSupplyTwoFailed (3),
|
|
powerSupplyOneandTwoFailed (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return powerSupply Alarm"
|
|
::= { rPDUPowerSupplyDevice 3 }
|
|
|
|
-- the rPDUStatus group
|
|
|
|
rPDUStatusBankTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Status Bank Table"
|
|
::= { rPDUStatus 1 }
|
|
|
|
|
|
rPDUStatusBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUStatusBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of each Rack PDU Bank"
|
|
::= { rPDUStatus 2 }
|
|
|
|
rPDUStatusBankEntry OBJECT-TYPE
|
|
SYNTAX RPDUStatusBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to Bank entries"
|
|
INDEX { rPDUStatusBankIndex }
|
|
::= { rPDUStatusBankTable 1 }
|
|
|
|
RPDUStatusBankEntry ::=
|
|
SEQUENCE {
|
|
rPDUStatusBankIndex INTEGER,
|
|
rPDUStatusBankNumber INTEGER,
|
|
rPDUStatusBankState INTEGER
|
|
}
|
|
|
|
rPDUStatusBankIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the RACK PDU Bank entry."
|
|
::= { rPDUStatusBankEntry 1 }
|
|
|
|
rPDUStatusBankNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bank number."
|
|
::= { rPDUStatusBankEntry 2 }
|
|
|
|
rPDUStatusBankState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bankLoadNormal (1),
|
|
bankLoadLow (2),
|
|
bankLoadNearOverload (3),
|
|
bankLoadOverload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bank load state.
|
|
|
|
bankLoadNormal(1) indicates that the bank is
|
|
operating properly within the rPDULoadBankConfigLowLoadThreshold
|
|
and rPDULoadBankConfigNearOverloadThreshold OID values.
|
|
|
|
bankLoadLow(2) indicates that the bank load has
|
|
dropped below the rPDULoadBankConfigLowLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
bankLoadNearOverload(3) indicates that the bank load
|
|
is greater than or equal to the
|
|
rPDULoadBankConfigNearOverloadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
bankLoadOverload(4) indicates that the bank load is
|
|
greater than or equal to the rPDULoadBankConfigOverloadThreshold
|
|
OID value.
|
|
An SNMP trap will occur when this state is entered or cleared."
|
|
::= { rPDUStatusBankEntry 3 }
|
|
|
|
-- Phase status table
|
|
|
|
rPDUStatusPhaseTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Status Phase Table"
|
|
::= { rPDUStatus 3 }
|
|
|
|
|
|
rPDUStatusPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUStatusPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of each Rack PDU Phase"
|
|
::= { rPDUStatus 4 }
|
|
|
|
rPDUStatusPhaseEntry OBJECT-TYPE
|
|
SYNTAX RPDUStatusPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to Phase entries"
|
|
INDEX { rPDUStatusPhaseIndex }
|
|
::= { rPDUStatusPhaseTable 1 }
|
|
|
|
RPDUStatusPhaseEntry ::=
|
|
SEQUENCE {
|
|
rPDUStatusPhaseIndex INTEGER,
|
|
rPDUStatusPhaseNumber INTEGER,
|
|
rPDUStatusPhaseState INTEGER
|
|
}
|
|
|
|
rPDUStatusPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the RACK PDU Phase entry."
|
|
::= { rPDUStatusPhaseEntry 1 }
|
|
|
|
rPDUStatusPhaseNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase number."
|
|
::= { rPDUStatusPhaseEntry 2 }
|
|
|
|
rPDUStatusPhaseState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phaseLoadNormal (1),
|
|
phaseLoadLow (2),
|
|
phaseLoadNearOverload (3),
|
|
phaseLoadOverload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Phase load state.
|
|
|
|
phaseLoadNormal(1) indicates that the Phase is
|
|
operating properly within the rPDULoadPhaseConfigLowLoadThreshold
|
|
and rPDULoadPhaseConfigNearOverloadThreshold OID values.
|
|
|
|
phaseLoadLow(2) indicates that the Phase load has
|
|
dropped below the rPDULoadPhaseConfigLowLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
phaseLoadNearOverload(3) indicates that the Phase load
|
|
is greater than or equal to the
|
|
rPDULoadPhaseConfigNearOverloadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
phaseLoadOverload(4) indicates that the Phase load is
|
|
greater than or equal to the rPDULoadPhaseConfigOverloadThreshold
|
|
OID value.
|
|
An SNMP trap will occur when this state is entered or cleared."
|
|
::= { rPDUStatusPhaseEntry 3 }
|
|
|
|
-- Outlet status table
|
|
|
|
rPDUStatusOutletTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Status Outlet Table"
|
|
::= { rPDUStatus 5 }
|
|
|
|
|
|
rPDUStatusOutletTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUStatusOutletEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU."
|
|
::= { rPDUStatus 6 }
|
|
|
|
rPDUStatusOutletEntry OBJECT-TYPE
|
|
SYNTAX RPDUStatusOutletEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to Outlet entries"
|
|
INDEX { rPDUStatusOutletIndex }
|
|
::= { rPDUStatusOutletTable 1 }
|
|
|
|
RPDUStatusOutletEntry ::=
|
|
SEQUENCE {
|
|
rPDUStatusOutletIndex INTEGER,
|
|
rPDUStatusOutletNumber INTEGER,
|
|
rPDUStatusOutletState INTEGER
|
|
}
|
|
|
|
rPDUStatusOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the RACK PDU Outlet entry."
|
|
::= { rPDUStatusOutletEntry 1 }
|
|
|
|
rPDUStatusOutletNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Outlet number."
|
|
::= { rPDUStatusOutletEntry 2 }
|
|
|
|
rPDUStatusOutletState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletLoadNormal (1),
|
|
outletLoadLow (2),
|
|
outletLoadNearOverload (3),
|
|
outletLoadOverload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Outlet load state.
|
|
|
|
outletLoadNormal(1) indicates that the Outlet is
|
|
operating properly within the rPDUOutletConfigMonitoredLowLoadThreshold
|
|
and rPDUOutletConfigMonitoredNearOverloadThreshold OID values.
|
|
|
|
outletLoadLow(2) indicates that the Outlet load has
|
|
dropped below the rPDUOutletConfigMonitoredLowLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
outletLoadNearOverload(3) indicates that the Outlet load
|
|
is greater than or equal to the
|
|
rPDUOutletConfigMonitoredNearOverloadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
outletLoadOverload(4) indicates that the Outlet load is
|
|
greater than or equal to the rPDUOutletConfigMonitoredOverloadThreshold
|
|
OID value.
|
|
An SNMP trap will occur when this state is entered or cleared."
|
|
::= { rPDUStatusOutletEntry 3 }
|
|
|
|
-- Common rPDU2 values
|
|
|
|
Rpdu2OutletPhaseLayoutType ::= INTEGER {
|
|
seqPhase1ToNeutral (1),
|
|
seqPhase2ToNeutral (2),
|
|
seqPhase3ToNeutral (3),
|
|
seqPhase1ToPhase2 (4),
|
|
seqPhase2ToPhase3 (5),
|
|
seqPhase3ToPhase1 (6)
|
|
}
|
|
|
|
-- rPDU2 Ident Table
|
|
|
|
rPDU2IdentTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of Rack PDUs"
|
|
::= { rPDU2 1 }
|
|
|
|
rPDU2IdentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2IdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU identification data"
|
|
::= { rPDU2 2 }
|
|
|
|
rPDU2IdentEntry OBJECT-TYPE
|
|
SYNTAX RPDU2IdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identification data from Rack PDU being queried"
|
|
INDEX { rPDU2IdentIndex }
|
|
::= { rPDU2IdentTable 1 }
|
|
|
|
RPDU2IdentEntry ::=
|
|
SEQUENCE {
|
|
rPDU2IdentIndex INTEGER,
|
|
rPDU2IdentModule INTEGER,
|
|
rPDU2IdentName DisplayString,
|
|
rPDU2IdentLocation DisplayString,
|
|
rPDU2IdentHardwareRev DisplayString,
|
|
rPDU2IdentFirmwareRev DisplayString,
|
|
rPDU2IdentDateOfManufacture DisplayString,
|
|
rPDU2IdentModelNumber DisplayString,
|
|
rPDU2IdentSerialNumber DisplayString,
|
|
rPDU2IdentContact DisplayString
|
|
}
|
|
|
|
rPDU2IdentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU identification table
|
|
entry"
|
|
::= { rPDU2IdentEntry 1 }
|
|
|
|
rPDU2IdentModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2IdentEntry 2 }
|
|
|
|
rPDU2IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the Rack PDU"
|
|
::= { rPDU2IdentEntry 3 }
|
|
|
|
rPDU2IdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the location
|
|
of the Rack PDU"
|
|
::= { rPDU2IdentEntry 4 }
|
|
|
|
rPDU2IdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU hardware version"
|
|
::= { rPDU2IdentEntry 5 }
|
|
|
|
rPDU2IdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU firware version"
|
|
::= { rPDU2IdentEntry 6 }
|
|
|
|
rPDU2IdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date the Rack PDU was manufactured
|
|
in mm/dd/yyyy format"
|
|
::= { rPDU2IdentEntry 7 }
|
|
|
|
rPDU2IdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU model number"
|
|
::= { rPDU2IdentEntry 8 }
|
|
|
|
rPDU2IdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU serial number"
|
|
::= { rPDU2IdentEntry 9 }
|
|
|
|
rPDU2IdentContact OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the
|
|
person to contact regarding the Rack PDU"
|
|
::= { rPDU2IdentEntry 10 }
|
|
|
|
-- rPDU2 Device Data
|
|
|
|
rPDU2DeviceTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of Rack PDUs"
|
|
::= { rPDU2 3 }
|
|
|
|
rPDU2Device OBJECT IDENTIFIER ::= { rPDU2 4 }
|
|
|
|
-- rPDU2 Device Config
|
|
|
|
rPDU2DeviceConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2DeviceConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU configuration data"
|
|
::= { rPDU2Device 1 }
|
|
|
|
rPDU2DeviceConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDU2DeviceConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from Rack PDU being queried"
|
|
INDEX { rPDU2DeviceConfigIndex }
|
|
::= { rPDU2DeviceConfigTable 1 }
|
|
|
|
RPDU2DeviceConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDU2DeviceConfigIndex INTEGER,
|
|
rPDU2DeviceConfigModule INTEGER,
|
|
rPDU2DeviceConfigName DisplayString,
|
|
rPDU2DeviceConfigLocation DisplayString,
|
|
rPDU2DeviceConfigDisplayOrientation INTEGER,
|
|
rPDU2DeviceConfigColdstartDelay INTEGER,
|
|
rPDU2DeviceConfigLowLoadPowerThreshold INTEGER,
|
|
rPDU2DeviceConfigNearOverloadPowerThreshold INTEGER,
|
|
rPDU2DeviceConfigOverloadPowerThreshold INTEGER,
|
|
rPDU2DeviceConfigDevicePeakPowerReset INTEGER,
|
|
rPDU2DeviceConfigDeviceEnergyReset INTEGER,
|
|
rPDU2DeviceConfigOutletsEnergyReset INTEGER,
|
|
rPDU2DeviceConfigOutletsPeakLoadReset INTEGER,
|
|
rPDU2DeviceConfigContact DisplayString
|
|
|
|
}
|
|
|
|
rPDU2DeviceConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU table entry"
|
|
::= { rPDU2DeviceConfigEntry 1 }
|
|
|
|
rPDU2DeviceConfigModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2DeviceConfigEntry 2 }
|
|
|
|
rPDU2DeviceConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the Rack PDU"
|
|
::= { rPDU2DeviceConfigEntry 3 }
|
|
|
|
rPDU2DeviceConfigLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the location
|
|
of the Rack PDU"
|
|
::= { rPDU2DeviceConfigEntry 4 }
|
|
|
|
rPDU2DeviceConfigDisplayOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
displayNormal (1),
|
|
displayReverse (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the intended physical orientation
|
|
of the seven segment display
|
|
|
|
displayNormal(1) indicates normal orientation
|
|
displayReverse(2) indicates upside down orientation"
|
|
::= { rPDU2DeviceConfigEntry 5 }
|
|
|
|
rPDU2DeviceConfigColdstartDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of delay, measured in seconds, between
|
|
when power is provided to the Rack PDU and when
|
|
the Rack PDU provides basic master power to the
|
|
outlets.
|
|
Allowed values are:
|
|
-1 - never apply power automatically.
|
|
0 - apply power immediately.
|
|
1 to 300 - delay up to 300 seconds (5 minutes)."
|
|
::= { rPDU2DeviceConfigEntry 6 }
|
|
|
|
rPDU2DeviceConfigLowLoadPowerThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined low power draw alarm threshold,
|
|
measured in tenths of kilowatts"
|
|
::= { rPDU2DeviceConfigEntry 7 }
|
|
|
|
rPDU2DeviceConfigNearOverloadPowerThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined near power overload threshold,
|
|
measured in tenths of kilowatts"
|
|
::= { rPDU2DeviceConfigEntry 8 }
|
|
|
|
rPDU2DeviceConfigOverloadPowerThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined power overload threshold,
|
|
measured in tenths of kilowatts"
|
|
::= { rPDU2DeviceConfigEntry 9 }
|
|
|
|
rPDU2DeviceConfigDevicePeakPowerReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the existing peak power value
|
|
to be replaced by the current load power value.
|
|
|
|
Getting this OID will do nothing and return the noOperation(1) value."
|
|
::= { rPDU2DeviceConfigEntry 10 }
|
|
|
|
rPDU2DeviceConfigDeviceEnergyReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2),
|
|
notSupported (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the device energy meter value
|
|
to be reset to zero.
|
|
|
|
Getting this OID in models that support this feature will do nothing
|
|
and return the noOperation(1) value.
|
|
|
|
Models that do not support this feature will respond to this OID
|
|
with a value of notSupported (3). Attempts to set this OID
|
|
in these models will fail."
|
|
::= { rPDU2DeviceConfigEntry 11 }
|
|
|
|
rPDU2DeviceConfigOutletsEnergyReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2),
|
|
notSupported (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the all outlet energy meter values
|
|
to be reset to zero.
|
|
|
|
Getting this OID will do nothing and return the noOperation(1) value.
|
|
|
|
Models that do not support this feature will respond to this OID
|
|
with a value of notSupported (3). Attempts to set this OID
|
|
in these models will fail."
|
|
::= { rPDU2DeviceConfigEntry 12 }
|
|
|
|
rPDU2DeviceConfigOutletsPeakLoadReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2),
|
|
notSupported (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the all outlet peak load values
|
|
to be reset to zero.
|
|
|
|
Getting this OID will do nothing and return the noOperation(1) value.
|
|
|
|
Models that do not support this feature will respond to this OID
|
|
with a value of notSupported (3). Attempts to set this OID
|
|
in these models will fail."
|
|
::= { rPDU2DeviceConfigEntry 13 }
|
|
|
|
rPDU2DeviceConfigContact OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the
|
|
person to contact regarding the Rack PDU"
|
|
::= { rPDU2DeviceConfigEntry 14 }
|
|
|
|
-- rPDU2 Device Properties
|
|
|
|
rPDU2DevicePropertiesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2DevicePropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU properties"
|
|
::= { rPDU2Device 2 }
|
|
|
|
rPDU2DevicePropertiesEntry OBJECT-TYPE
|
|
SYNTAX RPDU2DevicePropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Properties of the Rack PDU being queried"
|
|
INDEX { rPDU2DevicePropertiesIndex }
|
|
::= { rPDU2DevicePropertiesTable 1 }
|
|
|
|
RPDU2DevicePropertiesEntry ::=
|
|
SEQUENCE {
|
|
rPDU2DevicePropertiesIndex INTEGER,
|
|
rPDU2DevicePropertiesModule INTEGER,
|
|
rPDU2DevicePropertiesName DisplayString,
|
|
rPDU2DevicePropertiesNumOutlets INTEGER,
|
|
rPDU2DevicePropertiesNumSwitchedOutlets INTEGER,
|
|
rPDU2DevicePropertiesNumMeteredOutlets INTEGER,
|
|
rPDU2DevicePropertiesNumPhases INTEGER,
|
|
rPDU2DevicePropertiesNumMeteredBanks INTEGER,
|
|
rPDU2DevicePropertiesMaxCurrentRating INTEGER,
|
|
rPDU2DevicePropertiesOrientation INTEGER,
|
|
rPDU2DevicePropertiesOutletLayout INTEGER,
|
|
rPDU2DevicePropertiesMaxPhaseCurrentRating INTEGER
|
|
}
|
|
|
|
rPDU2DevicePropertiesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU properties table entry"
|
|
::= { rPDU2DevicePropertiesEntry 1 }
|
|
|
|
rPDU2DevicePropertiesModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2DevicePropertiesEntry 2 }
|
|
|
|
rPDU2DevicePropertiesName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the Rack PDU"
|
|
::= { rPDU2DevicePropertiesEntry 3 }
|
|
|
|
rPDU2DevicePropertiesNumOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of outlets on the Rack PDU"
|
|
::= { rPDU2DevicePropertiesEntry 4 }
|
|
|
|
rPDU2DevicePropertiesNumSwitchedOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of switched outlets on the Rack PDU"
|
|
::= { rPDU2DevicePropertiesEntry 5 }
|
|
|
|
rPDU2DevicePropertiesNumMeteredOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of metered outlets on the Rack PDU"
|
|
::= { rPDU2DevicePropertiesEntry 6 }
|
|
|
|
rPDU2DevicePropertiesNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of phases present in the Rack PDU"
|
|
::= { rPDU2DevicePropertiesEntry 7 }
|
|
|
|
rPDU2DevicePropertiesNumMeteredBanks OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of metered banks present in the Rack PDU"
|
|
::= { rPDU2DevicePropertiesEntry 8 }
|
|
|
|
rPDU2DevicePropertiesMaxCurrentRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum current rating, measured in Amps, for
|
|
the Rack PDU"
|
|
::= { rPDU2DevicePropertiesEntry 9 }
|
|
|
|
rPDU2DevicePropertiesOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
horizontal (1),
|
|
vertical (2),
|
|
verticalISXv2 (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Rack PDU orientation"
|
|
::= { rPDU2DevicePropertiesEntry 10 }
|
|
|
|
rPDU2DevicePropertiesOutletLayout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
seqPhaseToNeutral (1),
|
|
seqPhaseToPhase (2),
|
|
seqPhToNeu21PhToPh (3),
|
|
seqPhToPhGrouped (4),
|
|
seqPhToNGrouped (5),
|
|
seqPToN1516PToPGrouped (6),
|
|
seqPhToPh2xGrouped (7),
|
|
seqPhToN2xGrouped (8),
|
|
seqNotApplicable (9),
|
|
seqPhToNPhToPhPhToN (10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return outlet layout for the device.
|
|
|
|
seqPhaseToNeutral(1) indicates outlet layout as follows:
|
|
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
|
|
or for single phase SKUs, all outlets 1-N
|
|
|
|
seqPhaseToPhase(2) indicates outlet layout as follows:
|
|
1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,...
|
|
|
|
seqPhToNeu21PhToPh(3) indicates outlet layout as follows:
|
|
1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,...
|
|
|
|
seqPhToPhGrouped(4) indicates outlet layout as follows:
|
|
For AP8xxx SKU's Group 1:1-2, Group 2:2-3, Group 3:3-1.
|
|
|
|
seqPhToNGrouped(5) indicates outlet layout as follows:
|
|
This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N.
|
|
|
|
seqPToN1516PToPGrouped(6) indicates outlet layout as follows:
|
|
This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2,
|
|
Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1.
|
|
|
|
seqPhToPh2xGrouped(7) indicates outlet layout as follows:
|
|
This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3,
|
|
Group 4:2-3, Group 5:3-1, Group 6:3-1.
|
|
|
|
seqPhToN2xGrouped(8) indicates outlet layout as follows:
|
|
This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N,
|
|
Group 4:2-N, Group 5:3-N, Group 6:3-N.
|
|
|
|
seqNotApplicable(9):
|
|
Outlet layout does not affect any of the user interfaces for
|
|
AP88XX SKUs. These SKUs may report seqNotApplicable(9) if there is
|
|
not an exact outlet layout match available.
|
|
|
|
seqPhToNPhToPhPhToN(10) indicates outlet layout as follows:
|
|
Group 1:1-N, Group 2:1-2, Group 3:2-N."
|
|
::= { rPDU2DevicePropertiesEntry 11 }
|
|
|
|
rPDU2DevicePropertiesMaxPhaseCurrentRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum current rating, measured in Amps, for
|
|
the Rack PDU"
|
|
::= { rPDU2DevicePropertiesEntry 12 }
|
|
|
|
-- rPDU2 Device Status
|
|
|
|
rPDU2DeviceStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2DeviceStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU status information"
|
|
::= { rPDU2Device 3 }
|
|
|
|
rPDU2DeviceStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDU2DeviceStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status information from the Rack PDU being queried"
|
|
INDEX { rPDU2DeviceStatusIndex }
|
|
::= { rPDU2DeviceStatusTable 1 }
|
|
|
|
RPDU2DeviceStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDU2DeviceStatusIndex INTEGER,
|
|
rPDU2DeviceStatusModule INTEGER,
|
|
rPDU2DeviceStatusName DisplayString,
|
|
rPDU2DeviceStatusLoadState INTEGER,
|
|
rPDU2DeviceStatusPower INTEGER,
|
|
rPDU2DeviceStatusPeakPower INTEGER,
|
|
rPDU2DeviceStatusPeakPowerTimestamp DisplayString,
|
|
rPDU2DeviceStatusPeakPowerStartTime DisplayString,
|
|
rPDU2DeviceStatusEnergy INTEGER,
|
|
rPDU2DeviceStatusEnergyStartTime DisplayString,
|
|
rPDU2DeviceStatusCommandPending INTEGER,
|
|
rPDU2DeviceStatusPowerSupplyAlarm INTEGER,
|
|
rPDU2DeviceStatusPowerSupply1Status INTEGER,
|
|
rPDU2DeviceStatusPowerSupply2Status INTEGER,
|
|
rPDU2DeviceStatusOutletsEnergyStartTime DisplayString,
|
|
rPDU2DeviceStatusApparentPower INTEGER,
|
|
rPDU2DeviceStatusPowerFactor INTEGER,
|
|
rPDU2DeviceStatusNPSType INTEGER
|
|
}
|
|
|
|
rPDU2DeviceStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU status table entry"
|
|
::= { rPDU2DeviceStatusEntry 1 }
|
|
|
|
rPDU2DeviceStatusModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2DeviceStatusEntry 2 }
|
|
|
|
rPDU2DeviceStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the Rack PDU"
|
|
::= { rPDU2DeviceStatusEntry 3 }
|
|
|
|
rPDU2DeviceStatusLoadState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lowLoad (1),
|
|
normal (2),
|
|
nearOverload (3),
|
|
overload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present load status of the Rack PDU"
|
|
::= { rPDU2DeviceStatusEntry 4 }
|
|
|
|
rPDU2DeviceStatusPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power consumption of the Rack PDU load in hundredths of kilowatts"
|
|
::= { rPDU2DeviceStatusEntry 5 }
|
|
|
|
rPDU2DeviceStatusPeakPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak power consumption of the Rack PDU load in hundredths of kilowatts"
|
|
::= { rPDU2DeviceStatusEntry 6 }
|
|
|
|
rPDU2DeviceStatusPeakPowerTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time that peak power consumption occurred"
|
|
::= { rPDU2DeviceStatusEntry 7 }
|
|
|
|
rPDU2DeviceStatusPeakPowerStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the last device peak power reset"
|
|
::= { rPDU2DeviceStatusEntry 8 }
|
|
|
|
rPDU2DeviceStatusEnergy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user resettable energy meter measuring Rack PDU load
|
|
energy consumption in tenths of kilowatt-hours"
|
|
::= { rPDU2DeviceStatusEntry 9 }
|
|
|
|
rPDU2DeviceStatusEnergyStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the last device energy
|
|
meter reset"
|
|
::= { rPDU2DeviceStatusEntry 10 }
|
|
|
|
|
|
rPDU2DeviceStatusCommandPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
commandPending (1),
|
|
noCommandPending (2),
|
|
commandPendingUnknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not the device
|
|
is processing a pending command. If
|
|
the commandPendingUnknown (3) value is
|
|
returned, all devices powered by the
|
|
Rack PDU should be shut down. The
|
|
Rack PDU's power should then be cycled
|
|
to clear this condition."
|
|
::= { rPDU2DeviceStatusEntry 11 }
|
|
|
|
rPDU2DeviceStatusPowerSupplyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates a power supply alarm is active when value
|
|
equals alarm (2)"
|
|
::= { rPDU2DeviceStatusEntry 12 }
|
|
|
|
rPDU2DeviceStatusPowerSupply1Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2),
|
|
notInstalled (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not an alarm is active in Power
|
|
Supply 1"
|
|
::= { rPDU2DeviceStatusEntry 13 }
|
|
|
|
rPDU2DeviceStatusPowerSupply2Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2),
|
|
notInstalled (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not an alarm is active in Power
|
|
Supply 2"
|
|
::= { rPDU2DeviceStatusEntry 14 }
|
|
|
|
rPDU2DeviceStatusOutletsEnergyStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the last outlets energy
|
|
meter reset"
|
|
::= { rPDU2DeviceStatusEntry 15 }
|
|
|
|
rPDU2DeviceStatusApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The apparent power consumption of the Rack PDU load in hundredths of kiloVoltAmps (kVA)"
|
|
::= { rPDU2DeviceStatusEntry 16 }
|
|
|
|
rPDU2DeviceStatusPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power factor of the Rack PDU load in hundredths"
|
|
::= { rPDU2DeviceStatusEntry 17 }
|
|
|
|
rPDU2DeviceStatusNPSType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notNPS (1),
|
|
host (2),
|
|
guest (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The device NPS status:
|
|
notNPS (1) indicates the Rack PDU is not in an NPS group.
|
|
host (2) indicates the Rack PDU has been designated as a host in an NPS group.
|
|
Only one Rack PDU in an NPS group is allowed to be the host.
|
|
guest (3) indicates the Rack PDU has been designated as a guest in an NPS group."
|
|
::= { rPDU2DeviceStatusEntry 18 }
|
|
|
|
-- rPDU2 Device Control
|
|
|
|
rPDU2DeviceControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2DeviceControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU control data"
|
|
::= { rPDU2Device 4 }
|
|
|
|
rPDU2DeviceControlEntry OBJECT-TYPE
|
|
SYNTAX RPDU2DeviceControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control data from Rack PDU being queried"
|
|
INDEX { rPDU2DeviceControlIndex }
|
|
::= { rPDU2DeviceControlTable 1 }
|
|
|
|
RPDU2DeviceControlEntry ::=
|
|
SEQUENCE {
|
|
rPDU2DeviceControlIndex INTEGER,
|
|
rPDU2DeviceControlModule INTEGER,
|
|
rPDU2DeviceControlName DisplayString,
|
|
rPDU2DeviceControlCommand INTEGER
|
|
}
|
|
|
|
rPDU2DeviceControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU control table entry"
|
|
::= { rPDU2DeviceControlEntry 1 }
|
|
|
|
rPDU2DeviceControlModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2DeviceControlEntry 2 }
|
|
|
|
rPDU2DeviceControlName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the Rack PDU"
|
|
::= { rPDU2DeviceControlEntry 3 }
|
|
|
|
rPDU2DeviceControlCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
immediateAllOn (1),
|
|
delayedAllOn (2),
|
|
immediateAllOff (3),
|
|
immediateAllReboot (4),
|
|
delayedAllReboot (5),
|
|
noCommandAll (6),
|
|
delayedAllOff (7),
|
|
cancelAllPendingCommands (8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to immediateAllOn (1) will turn all outlets
|
|
on immediately.
|
|
|
|
Setting this OID to delayedAllOn (2) will turn all outlets on as
|
|
defined by each outlet's rPDU2OutletSwitchedConfigPowerOnTime
|
|
OID value.
|
|
|
|
Setting this OID to immediateAllOff (3) will turn all outlets
|
|
off immediately.
|
|
|
|
Setting this OID to immediateAllReboot (4) will cause an immediateAllOff
|
|
command to be performed. Once all outlets are off, the
|
|
Switched Rack PDU will then delay the
|
|
rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform an
|
|
immediateAllOn command.
|
|
|
|
Setting this OID to delayedAllReboot (5) will cause a
|
|
delayedAllOff command to be performed. Once all outlets are off,
|
|
the Switched Rack PDU will then delay the largest
|
|
rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform a
|
|
delayedAllOn command.
|
|
|
|
Setting this OID to noCommandAll (6) will have no effect.
|
|
|
|
Setting this OID to delayedAllOff (7) will turn all outlets off
|
|
as defined by each outlet's rPDU2OutletSwitchedConfigPowerOffTime
|
|
OID value.
|
|
|
|
Setting this OID to cancelAllPendingCommands (8) will cause all pending
|
|
commands on the Switched Rack PDU to be cancelled.
|
|
|
|
Getting this OID will return the noCommandAll (6)
|
|
value."
|
|
::= { rPDU2DeviceControlEntry 4 }
|
|
|
|
-- rPDU2 Phase Data
|
|
|
|
rPDU2PhaseTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected Rack PDU phases"
|
|
::= { rPDU2 5}
|
|
|
|
rPDU2Phase OBJECT IDENTIFIER ::= { rPDU2 6 }
|
|
|
|
-- rPDU2 Phase Config
|
|
|
|
rPDU2PhaseConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2PhaseConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU phase configuration data"
|
|
::= { rPDU2Phase 1 }
|
|
|
|
rPDU2PhaseConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDU2PhaseConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from currently queried Rack
|
|
PDU phase"
|
|
INDEX { rPDU2PhaseConfigIndex }
|
|
::= { rPDU2PhaseConfigTable 1 }
|
|
|
|
RPDU2PhaseConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDU2PhaseConfigIndex INTEGER,
|
|
rPDU2PhaseConfigModule INTEGER,
|
|
rPDU2PhaseConfigNumber INTEGER,
|
|
rPDU2PhaseConfigOverloadRestriction INTEGER,
|
|
rPDU2PhaseConfigLowLoadCurrentThreshold INTEGER,
|
|
rPDU2PhaseConfigNearOverloadCurrentThreshold INTEGER,
|
|
rPDU2PhaseConfigOverloadCurrentThreshold INTEGER,
|
|
rPDU2PhaseConfigPhasePeakCurrentReset INTEGER
|
|
}
|
|
|
|
rPDU2PhaseConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase configuration
|
|
table entry"
|
|
::= { rPDU2PhaseConfigEntry 1 }
|
|
|
|
rPDU2PhaseConfigModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2PhaseConfigEntry 2 }
|
|
|
|
rPDU2PhaseConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric phase ID"
|
|
::= { rPDU2PhaseConfigEntry 3 }
|
|
|
|
rPDU2PhaseConfigOverloadRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysAllowTurnON (1),
|
|
restrictOnNearOverload (2),
|
|
restrictOnOverload (3),
|
|
notSupported (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of a Switched Rack PDU
|
|
phase when an overload condition is possible and
|
|
additional outlets are requested to be turned on.
|
|
|
|
Setting this OID to alwaysAllowTurnON (1) will always allow
|
|
the outlets on the corresponding phase to turn on.
|
|
|
|
Setting this OID to restrictOnNearOverload (2) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
rPDULoadConfigNearOverloadThreshold OID is exceeded.
|
|
|
|
Setting this OID to restrictOnOverload (3) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
rPDULoadConfigOverloadThreshold OID is exceeded.
|
|
|
|
Models that do not support this feature will respond to this OID
|
|
with a value of notSupported (4). Attempts to set this OID
|
|
in these models will fail."
|
|
::= { rPDU2PhaseConfigEntry 4 }
|
|
|
|
rPDU2PhaseConfigLowLoadCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined low load phase current
|
|
threshold in Amps"
|
|
::= { rPDU2PhaseConfigEntry 5 }
|
|
|
|
rPDU2PhaseConfigNearOverloadCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined near phase overload warning
|
|
threshold in Amps"
|
|
::= { rPDU2PhaseConfigEntry 6 }
|
|
|
|
rPDU2PhaseConfigOverloadCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined phase overload current
|
|
threshold in Amps"
|
|
::= { rPDU2PhaseConfigEntry 7 }
|
|
|
|
rPDU2PhaseConfigPhasePeakCurrentReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the existing peak current value
|
|
to be replaced by the present load current value.
|
|
|
|
Getting this OID will do nothing and return the noOperation(1) value."
|
|
::= { rPDU2PhaseConfigEntry 8 }
|
|
|
|
|
|
-- rPDU2 Phase Properties
|
|
|
|
rPDU2PhasePropertiesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2PhasePropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU phase properties"
|
|
::= { rPDU2Phase 2 }
|
|
|
|
rPDU2PhasePropertiesEntry OBJECT-TYPE
|
|
SYNTAX RPDU2PhasePropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Properties of the currently queried Rack
|
|
PDU phase"
|
|
INDEX { rPDU2PhasePropertiesIndex }
|
|
::= { rPDU2PhasePropertiesTable 1 }
|
|
|
|
RPDU2PhasePropertiesEntry ::=
|
|
SEQUENCE {
|
|
rPDU2PhasePropertiesIndex INTEGER,
|
|
rPDU2PhasePropertiesModule INTEGER,
|
|
rPDU2PhasePropertiesNumber INTEGER
|
|
}
|
|
|
|
rPDU2PhasePropertiesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase properties
|
|
table entry"
|
|
::= { rPDU2PhasePropertiesEntry 1 }
|
|
|
|
rPDU2PhasePropertiesModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2PhasePropertiesEntry 2 }
|
|
|
|
rPDU2PhasePropertiesNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric phase ID"
|
|
::= { rPDU2PhasePropertiesEntry 3 }
|
|
|
|
-- rPDU2 Phase Status
|
|
|
|
rPDU2PhaseStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2PhaseStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU phase status data"
|
|
::= { rPDU2Phase 3 }
|
|
|
|
rPDU2PhaseStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDU2PhaseStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status data from currently queried Rack PDU
|
|
phase"
|
|
INDEX { rPDU2PhaseStatusIndex }
|
|
::= { rPDU2PhaseStatusTable 1 }
|
|
|
|
RPDU2PhaseStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDU2PhaseStatusIndex INTEGER,
|
|
rPDU2PhaseStatusModule INTEGER,
|
|
rPDU2PhaseStatusNumber INTEGER,
|
|
rPDU2PhaseStatusLoadState INTEGER,
|
|
rPDU2PhaseStatusCurrent INTEGER,
|
|
rPDU2PhaseStatusVoltage INTEGER,
|
|
rPDU2PhaseStatusPower INTEGER,
|
|
rPDU2PhaseStatusApparentPower INTEGER,
|
|
rPDU2PhaseStatusPowerFactor INTEGER,
|
|
rPDU2PhaseStatusPeakCurrent INTEGER,
|
|
rPDU2PhaseStatusPeakCurrentTimestamp DisplayString,
|
|
rPDU2PhaseStatusPeakCurrentStartTime DisplayString
|
|
}
|
|
|
|
rPDU2PhaseStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase status table
|
|
entry"
|
|
::= { rPDU2PhaseStatusEntry 1 }
|
|
|
|
rPDU2PhaseStatusModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2PhaseStatusEntry 2 }
|
|
|
|
rPDU2PhaseStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric phase ID"
|
|
::= { rPDU2PhaseStatusEntry 3 }
|
|
|
|
rPDU2PhaseStatusLoadState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lowLoad (1),
|
|
normal (2),
|
|
nearOverload (3),
|
|
overload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present load status of the Rack PDU
|
|
phase being queried"
|
|
::= { rPDU2PhaseStatusEntry 4 }
|
|
|
|
rPDU2PhaseStatusCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the current draw, in tenths of Amps, of the load
|
|
on the Rack PDU phase being queried"
|
|
::= { rPDU2PhaseStatusEntry 5 }
|
|
|
|
rPDU2PhaseStatusVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Voltage, in Volts, of the Rack
|
|
PDU phase being queried"
|
|
::= { rPDU2PhaseStatusEntry 6 }
|
|
|
|
rPDU2PhaseStatusPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the load power, in hundredths of kilowatts (kW),
|
|
consumed on the Rack PDU phase being queried"
|
|
::= { rPDU2PhaseStatusEntry 7 }
|
|
|
|
rPDU2PhaseStatusApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the load apparent power, in hundredths of kiloVoltAmps (kVA),
|
|
consumed on the Rack PDU phase being queried"
|
|
::= { rPDU2PhaseStatusEntry 8 }
|
|
|
|
rPDU2PhaseStatusPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the load power factor, in hundredths,
|
|
of the Rack PDU phase being queried"
|
|
::= { rPDU2PhaseStatusEntry 9 }
|
|
|
|
|
|
rPDU2PhaseStatusPeakCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak current of the Rack PDU phase load in tenths of Amps"
|
|
::= { rPDU2PhaseStatusEntry 10 }
|
|
|
|
rPDU2PhaseStatusPeakCurrentTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time that the peak current occurred"
|
|
::= { rPDU2PhaseStatusEntry 11 }
|
|
|
|
rPDU2PhaseStatusPeakCurrentStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the last phase peak current reset"
|
|
::= { rPDU2PhaseStatusEntry 12 }
|
|
|
|
-- rPDU2 Bank Data
|
|
|
|
rPDU2BankTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected Rack PDU banks"
|
|
::= { rPDU2 7}
|
|
|
|
rPDU2Bank OBJECT IDENTIFIER ::= { rPDU2 8 }
|
|
|
|
-- rPDU2 Bank Config
|
|
|
|
rPDU2BankConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2BankConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU bank configuration data"
|
|
::= { rPDU2Bank 1 }
|
|
|
|
rPDU2BankConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDU2BankConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from currently queried
|
|
Rack PDU bank"
|
|
INDEX { rPDU2BankConfigIndex }
|
|
::= { rPDU2BankConfigTable 1 }
|
|
|
|
RPDU2BankConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDU2BankConfigIndex INTEGER,
|
|
rPDU2BankConfigModule INTEGER,
|
|
rPDU2BankConfigNumber INTEGER,
|
|
rPDU2BankConfigOverloadRestriction INTEGER,
|
|
rPDU2BankConfigLowLoadCurrentThreshold INTEGER,
|
|
rPDU2BankConfigNearOverloadCurrentThreshold INTEGER,
|
|
rPDU2BankConfigOverloadCurrentThreshold INTEGER,
|
|
rPDU2BankConfigBankPeakCurrentReset INTEGER
|
|
}
|
|
|
|
rPDU2BankConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU bank configuration
|
|
table entry"
|
|
::= { rPDU2BankConfigEntry 1 }
|
|
|
|
rPDU2BankConfigModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2BankConfigEntry 2 }
|
|
|
|
rPDU2BankConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric bank ID"
|
|
::= { rPDU2BankConfigEntry 3 }
|
|
|
|
rPDU2BankConfigOverloadRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysAllowTurnON (1),
|
|
restrictOnNearOverload (2),
|
|
restrictOnOverload (3),
|
|
notSupported (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of a Switched Rack PDU
|
|
bank when an overload condition is possible and
|
|
additional outlets are requested to be turned on.
|
|
|
|
Setting this OID to alwaysAllowTurnON (1) will always allow
|
|
the outlets on the corresponding bank to turn on.
|
|
|
|
Setting this OID to restrictOnNearOverload (2) will not allow
|
|
outlets on the corresponding bank to turn on if the
|
|
rPDU2BankConfigNearOverloadCurrentThreshold OID is exceeded.
|
|
|
|
Setting this OID to restrictOnOverload (3) will not allow
|
|
outlets on the corresponding bank to turn on if the
|
|
rPDU2BankConfigOverloadCurrentThreshold OID is exceeded.
|
|
|
|
Models that do not support this feature will respond to this OID
|
|
with a value of notSupported (4). Attempts to set this OID
|
|
in these models will fail."
|
|
::= { rPDU2BankConfigEntry 4 }
|
|
|
|
rPDU2BankConfigLowLoadCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined low load bank current
|
|
threshold in Amps"
|
|
::= { rPDU2BankConfigEntry 5 }
|
|
|
|
rPDU2BankConfigNearOverloadCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined near bank overload current warning
|
|
threshold in Amps"
|
|
::= { rPDU2BankConfigEntry 6 }
|
|
|
|
rPDU2BankConfigOverloadCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined bank overload current threshold
|
|
in Amps"
|
|
::= { rPDU2BankConfigEntry 7 }
|
|
|
|
rPDU2BankConfigBankPeakCurrentReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the existing peak current value
|
|
to be replaced by the present load current value.
|
|
|
|
Getting this OID will do nothing and return the noOperation(1) value."
|
|
::= { rPDU2BankConfigEntry 8 }
|
|
|
|
-- rPDU2 Bank Properties
|
|
|
|
rPDU2BankPropertiesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2BankPropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU bank properties"
|
|
::= { rPDU2Bank 2 }
|
|
|
|
rPDU2BankPropertiesEntry OBJECT-TYPE
|
|
SYNTAX RPDU2BankPropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Properties of the currently queried
|
|
Rack PDU bank"
|
|
INDEX { rPDU2BankPropertiesIndex }
|
|
::= { rPDU2BankPropertiesTable 1 }
|
|
|
|
RPDU2BankPropertiesEntry ::=
|
|
SEQUENCE {
|
|
rPDU2BankPropertiesIndex INTEGER,
|
|
rPDU2BankPropertiesModule INTEGER,
|
|
rPDU2BankPropertiesNumber INTEGER,
|
|
rPDU2BankPropertiesPhaseLayout Rpdu2OutletPhaseLayoutType
|
|
}
|
|
|
|
rPDU2BankPropertiesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU bank properties
|
|
table entry"
|
|
::= { rPDU2BankPropertiesEntry 1 }
|
|
|
|
rPDU2BankPropertiesModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2BankPropertiesEntry 2 }
|
|
|
|
rPDU2BankPropertiesNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric bank ID"
|
|
::= { rPDU2BankPropertiesEntry 3 }
|
|
|
|
rPDU2BankPropertiesPhaseLayout OBJECT-TYPE
|
|
SYNTAX Rpdu2OutletPhaseLayoutType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID describes the outlet phase connections on
|
|
the referenced bank as follows:
|
|
|
|
seqPhase1ToNeutral(1) indicates that bank outlets are
|
|
wired from Phase 1 to Neutral.
|
|
|
|
seqPhase2ToNeutral(2) indicates that bank outlets are
|
|
wired from Phase 2 to Neutral.
|
|
|
|
seqPhase3ToNeutral(3) indicates that bank outlets are
|
|
wired from Phase 3 to Neutral.
|
|
|
|
seqPhase1ToPhase2(4) indicates that bank outlets are
|
|
wired from Phase 1 to Phase 2.
|
|
|
|
seqPhase2ToPhase3(5) indicates that bank outlets are
|
|
wired from Phase 2 to Phase 3.
|
|
|
|
seqPhase3ToPhase1(6) indicates that bank outlets are
|
|
wired from Phase 3 to Phase 1."
|
|
::= { rPDU2BankPropertiesEntry 4 }
|
|
|
|
-- rPDU2 Bank Status
|
|
|
|
rPDU2BankStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2BankStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU bank status data"
|
|
::= { rPDU2Bank 3 }
|
|
|
|
rPDU2BankStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDU2BankStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status data from currently queried Rack PDU
|
|
bank"
|
|
INDEX { rPDU2BankStatusIndex }
|
|
::= { rPDU2BankStatusTable 1 }
|
|
|
|
RPDU2BankStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDU2BankStatusIndex INTEGER,
|
|
rPDU2BankStatusModule INTEGER,
|
|
rPDU2BankStatusNumber INTEGER,
|
|
rPDU2BankStatusLoadState INTEGER,
|
|
rPDU2BankStatusCurrent INTEGER,
|
|
rPDU2BankStatusPeakCurrent INTEGER,
|
|
rPDU2BankStatusPeakCurrentTimestamp DisplayString,
|
|
rPDU2BankStatusPeakCurrentStartTime DisplayString
|
|
}
|
|
|
|
rPDU2BankStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU bank status
|
|
table entry"
|
|
::= { rPDU2BankStatusEntry 1 }
|
|
|
|
rPDU2BankStatusModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2BankStatusEntry 2 }
|
|
|
|
rPDU2BankStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric bank ID"
|
|
::= { rPDU2BankStatusEntry 3 }
|
|
|
|
rPDU2BankStatusLoadState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lowLoad (1),
|
|
normal (2),
|
|
nearOverload (3),
|
|
overload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present load status of the Rack PDU
|
|
bank being queried"
|
|
::= { rPDU2BankStatusEntry 4 }
|
|
|
|
rPDU2BankStatusCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the current draw, in tenths of Amps, of the load
|
|
on the Rack PDU bank being queried"
|
|
::= { rPDU2BankStatusEntry 5 }
|
|
|
|
rPDU2BankStatusPeakCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak current of the Rack PDU bank load in tenths of Amps"
|
|
::= { rPDU2BankStatusEntry 6 }
|
|
|
|
rPDU2BankStatusPeakCurrentTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time the bank peak current occurred"
|
|
::= { rPDU2BankStatusEntry 7 }
|
|
|
|
rPDU2BankStatusPeakCurrentStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the last bank peak current reset"
|
|
::= { rPDU2BankStatusEntry 8 }
|
|
|
|
-- rPDU2 Outlet Data
|
|
|
|
rPDU2Outlet OBJECT IDENTIFIER ::= { rPDU2 9 }
|
|
|
|
-- rPDU2 Switched Outlet Data
|
|
|
|
rPDU2OutletSwitchedTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of switched outlets on connected Rack PDUs"
|
|
::= { rPDU2Outlet 1}
|
|
|
|
rPDU2OutletSwitched OBJECT IDENTIFIER ::= { rPDU2Outlet 2 }
|
|
|
|
-- rPDU2 Switched Outlet Config
|
|
|
|
rPDU2OutletSwitchedConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2OutletSwitchedConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU switched outlet configuration data"
|
|
::= { rPDU2OutletSwitched 1 }
|
|
|
|
rPDU2OutletSwitchedConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDU2OutletSwitchedConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from currently queried
|
|
Rack PDU switched outlet"
|
|
INDEX { rPDU2OutletSwitchedConfigIndex }
|
|
::= { rPDU2OutletSwitchedConfigTable 1 }
|
|
|
|
RPDU2OutletSwitchedConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDU2OutletSwitchedConfigIndex INTEGER,
|
|
rPDU2OutletSwitchedConfigModule INTEGER,
|
|
rPDU2OutletSwitchedConfigName DisplayString,
|
|
rPDU2OutletSwitchedConfigNumber INTEGER,
|
|
rPDU2OutletSwitchedConfigPowerOnTime INTEGER,
|
|
rPDU2OutletSwitchedConfigPowerOffTime INTEGER,
|
|
rPDU2OutletSwitchedConfigRebootDuration INTEGER
|
|
}
|
|
|
|
rPDU2OutletSwitchedConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU switched outlet
|
|
configuration table entry"
|
|
::= { rPDU2OutletSwitchedConfigEntry 1 }
|
|
|
|
rPDU2OutletSwitchedConfigModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2OutletSwitchedConfigEntry 2 }
|
|
|
|
rPDU2OutletSwitchedConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined switched outlet ID string"
|
|
::= { rPDU2OutletSwitchedConfigEntry 3 }
|
|
|
|
rPDU2OutletSwitchedConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID"
|
|
::= { rPDU2OutletSwitchedConfigEntry 4 }
|
|
|
|
rPDU2OutletSwitchedConfigPowerOnTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of delay, in seconds, between when
|
|
power is provided to the Rack PDU and when
|
|
this switched outlet starts providing power.
|
|
Range -1...300 where -1 = Never power on,
|
|
0 = immediate power on, and 1-300 = seconds to
|
|
delay."
|
|
::= { rPDU2OutletSwitchedConfigEntry 5 }
|
|
|
|
rPDU2OutletSwitchedConfigPowerOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time, in seconds, this outlet will
|
|
delay powering off.
|
|
Range -1...300 where -1 = Never power off,
|
|
0 = immediate power off, and 1-300 = seconds to
|
|
delay."
|
|
::= { rPDU2OutletSwitchedConfigEntry 6 }
|
|
|
|
rPDU2OutletSwitchedConfigRebootDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After turning power off during a reboot sequence,
|
|
the amount of time to wait before turning power
|
|
to this outlet back on.
|
|
Range 5-60 seconds delay."
|
|
::= { rPDU2OutletSwitchedConfigEntry 7 }
|
|
|
|
-- rPDU2 Switched Outlet Config
|
|
|
|
rPDU2OutletSwitchedPropertiesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2OutletSwitchedPropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU switched outlet properties"
|
|
::= { rPDU2OutletSwitched 2 }
|
|
|
|
rPDU2OutletSwitchedPropertiesEntry OBJECT-TYPE
|
|
SYNTAX RPDU2OutletSwitchedPropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Properties of the currently queried Rack PDU
|
|
switched outlet"
|
|
INDEX { rPDU2OutletSwitchedPropertiesIndex }
|
|
::= { rPDU2OutletSwitchedPropertiesTable 1 }
|
|
|
|
RPDU2OutletSwitchedPropertiesEntry ::=
|
|
SEQUENCE {
|
|
rPDU2OutletSwitchedPropertiesIndex INTEGER,
|
|
rPDU2OutletSwitchedPropertiesModule INTEGER,
|
|
rPDU2OutletSwitchedPropertiesName DisplayString,
|
|
rPDU2OutletSwitchedPropertiesNumber INTEGER,
|
|
rPDU2OutletSwitchedPropertiesPhaseLayout Rpdu2OutletPhaseLayoutType,
|
|
rPDU2OutletSwitchedPropertiesBank INTEGER
|
|
}
|
|
|
|
rPDU2OutletSwitchedPropertiesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU switched outlet
|
|
properties table entry"
|
|
::= { rPDU2OutletSwitchedPropertiesEntry 1 }
|
|
|
|
rPDU2OutletSwitchedPropertiesModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2OutletSwitchedPropertiesEntry 2 }
|
|
|
|
rPDU2OutletSwitchedPropertiesName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined switched outlet ID string"
|
|
::= { rPDU2OutletSwitchedPropertiesEntry 3 }
|
|
|
|
rPDU2OutletSwitchedPropertiesNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID"
|
|
::= { rPDU2OutletSwitchedPropertiesEntry 4 }
|
|
|
|
rPDU2OutletSwitchedPropertiesPhaseLayout OBJECT-TYPE
|
|
SYNTAX Rpdu2OutletPhaseLayoutType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID describes the phase connections of
|
|
the referenced outlet as follows:
|
|
|
|
seqPhase1ToNeutral(1) indicates that the outlet is
|
|
wired from Phase 1 to Neutral.
|
|
|
|
seqPhase2ToNeutral(2) indicates that the outlet is
|
|
wired from Phase 2 to Neutral.
|
|
|
|
seqPhase3ToNeutral(3) indicates that the outlet is
|
|
wired from Phase 3 to Neutral.
|
|
|
|
seqPhase1ToPhase2(4) indicates that the outlet is
|
|
wired from Phase 1 to Phase 2.
|
|
|
|
seqPhase2ToPhase3(5) indicates that the outlet is
|
|
wired from Phase 2 to Phase 3.
|
|
|
|
seqPhase3ToPhase1(6) indicates that the outlet is
|
|
wired from Phase 3 to Phase 1."
|
|
::= { rPDU2OutletSwitchedPropertiesEntry 5 }
|
|
|
|
rPDU2OutletSwitchedPropertiesBank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric bank ID"
|
|
::= { rPDU2OutletSwitchedPropertiesEntry 6 }
|
|
|
|
-- rPDU2 Switched Outlet Status
|
|
|
|
rPDU2OutletSwitchedStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2OutletSwitchedStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU switched outlet status
|
|
information"
|
|
::= { rPDU2OutletSwitched 3 }
|
|
|
|
rPDU2OutletSwitchedStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDU2OutletSwitchedStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status information for currently queried
|
|
Rack PDU switched outlet"
|
|
INDEX { rPDU2OutletSwitchedStatusIndex }
|
|
::= { rPDU2OutletSwitchedStatusTable 1 }
|
|
|
|
RPDU2OutletSwitchedStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDU2OutletSwitchedStatusIndex INTEGER,
|
|
rPDU2OutletSwitchedStatusModule INTEGER,
|
|
rPDU2OutletSwitchedStatusName DisplayString,
|
|
rPDU2OutletSwitchedStatusNumber INTEGER,
|
|
rPDU2OutletSwitchedStatusState INTEGER,
|
|
rPDU2OutletSwitchedStatusCommandPending INTEGER
|
|
}
|
|
|
|
rPDU2OutletSwitchedStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU switched outlet
|
|
status information table entry"
|
|
::= { rPDU2OutletSwitchedStatusEntry 1 }
|
|
|
|
rPDU2OutletSwitchedStatusModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2OutletSwitchedStatusEntry 2 }
|
|
|
|
rPDU2OutletSwitchedStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined switched outlet ID string"
|
|
::= { rPDU2OutletSwitchedStatusEntry 3 }
|
|
|
|
rPDU2OutletSwitchedStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID"
|
|
::= { rPDU2OutletSwitchedStatusEntry 4 }
|
|
|
|
rPDU2OutletSwitchedStatusState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present switch state of the Rack
|
|
PDU switched outlet being queried"
|
|
::= { rPDU2OutletSwitchedStatusEntry 5 }
|
|
|
|
rPDU2OutletSwitchedStatusCommandPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
commandPending (1),
|
|
noCommandPending (2),
|
|
commandPendingUnknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not the device is
|
|
processing a command for this outlet.
|
|
|
|
If the commandPendingUnknown (3) value is
|
|
returned, all devices powered by the Rack PDU
|
|
should be shut down. The Rack PDU's power
|
|
should then be cycled to clear this condition."
|
|
::= { rPDU2OutletSwitchedStatusEntry 6 }
|
|
|
|
-- rPDU2 Switched Outlet Control
|
|
|
|
rPDU2OutletSwitchedControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2OutletSwitchedControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU switched outlet control
|
|
data"
|
|
::= { rPDU2OutletSwitched 4 }
|
|
|
|
rPDU2OutletSwitchedControlEntry OBJECT-TYPE
|
|
SYNTAX RPDU2OutletSwitchedControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control data for currently queried Rack
|
|
PDU switched outlet"
|
|
INDEX { rPDU2OutletSwitchedControlIndex }
|
|
::= { rPDU2OutletSwitchedControlTable 1 }
|
|
|
|
RPDU2OutletSwitchedControlEntry ::=
|
|
SEQUENCE {
|
|
rPDU2OutletSwitchedControlIndex INTEGER,
|
|
rPDU2OutletSwitchedControlModule INTEGER,
|
|
rPDU2OutletSwitchedControlName DisplayString,
|
|
rPDU2OutletSwitchedControlNumber INTEGER,
|
|
rPDU2OutletSwitchedControlCommand INTEGER
|
|
}
|
|
|
|
rPDU2OutletSwitchedControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU switched outlet
|
|
control data table entry"
|
|
::= { rPDU2OutletSwitchedControlEntry 1 }
|
|
|
|
rPDU2OutletSwitchedControlModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2OutletSwitchedControlEntry 2 }
|
|
|
|
rPDU2OutletSwitchedControlName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined switched outlet ID string"
|
|
::= { rPDU2OutletSwitchedControlEntry 3 }
|
|
|
|
rPDU2OutletSwitchedControlNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID"
|
|
::= { rPDU2OutletSwitchedControlEntry 4 }
|
|
|
|
rPDU2OutletSwitchedControlCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
immediateOn (1),
|
|
immediateOff (2),
|
|
immediateReboot (3),
|
|
outletUnknown (4),
|
|
delayedOn (5),
|
|
delayedOff (6),
|
|
delayedReboot (7),
|
|
cancelPendingCommand (8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the immediateOn (1) value will be returned.
|
|
If the outlet is off, the immediateOff (2) value will be
|
|
returned. If the state of the outlet cannot be
|
|
determined, the outletUnknown (4) value will be returned.
|
|
If the outletUnknown condition should occur, all devices
|
|
powered by the PDU should be shut down. The PDU's power
|
|
should then be cycled to clear this condition.
|
|
|
|
Setting this variable to immediateOn (1) will immediately turn
|
|
the outlet on.
|
|
|
|
Setting this variable to immediateOff (2) will immediately turn
|
|
the outlet off.
|
|
|
|
Setting this variable to immediateReboot (3) will cause the
|
|
Switched Rack PDU to perform an immediateOff command, wait the
|
|
rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform an
|
|
immediateOn command.
|
|
|
|
Setting this variable to delayedOn (5) will turn the outlet on
|
|
after the rPDU2OutletSwitchedConfigPowerOnTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedOff (6) will turn the outlet off
|
|
after the rPDU2OutletSwitchedConfigPowerOffTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedReboot (7) will cause the
|
|
Switched Rack PDU to perform a delayedOff command, wait the
|
|
rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform a
|
|
delayedOn command.
|
|
|
|
Setting this variable to cancelPendingCommand (8) will cause any
|
|
pending command to this outlet to be cancelled."
|
|
::= { rPDU2OutletSwitchedControlEntry 5 }
|
|
|
|
-- rPDU2 Metered Outlet Data
|
|
|
|
rPDU2OutletMeteredTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of metered outlets on connect Rack PDUs"
|
|
::= { rPDU2Outlet 3}
|
|
|
|
rPDU2OutletMetered OBJECT IDENTIFIER ::= { rPDU2Outlet 4 }
|
|
|
|
-- rPDU2 Metered Outlet Config
|
|
|
|
rPDU2OutletMeteredConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2OutletMeteredConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU metered outlet configuration data"
|
|
::= { rPDU2OutletMetered 1 }
|
|
|
|
rPDU2OutletMeteredConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDU2OutletMeteredConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from currently queried
|
|
Rack PDU metered outlet"
|
|
INDEX { rPDU2OutletMeteredConfigIndex }
|
|
::= { rPDU2OutletMeteredConfigTable 1 }
|
|
|
|
RPDU2OutletMeteredConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDU2OutletMeteredConfigIndex INTEGER,
|
|
rPDU2OutletMeteredConfigModule INTEGER,
|
|
rPDU2OutletMeteredConfigName DisplayString,
|
|
rPDU2OutletMeteredConfigNumber INTEGER,
|
|
rPDU2OutletMeteredConfigLowLoadCurrentThreshold INTEGER,
|
|
rPDU2OutletMeteredConfigNearOverloadCurrentThreshold INTEGER,
|
|
rPDU2OutletMeteredConfigOverloadCurrentThreshold INTEGER
|
|
}
|
|
|
|
rPDU2OutletMeteredConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU metered outlet
|
|
configuration table entry"
|
|
::= { rPDU2OutletMeteredConfigEntry 1 }
|
|
|
|
rPDU2OutletMeteredConfigModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2OutletMeteredConfigEntry 2 }
|
|
|
|
rPDU2OutletMeteredConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined metered outlet ID string"
|
|
::= { rPDU2OutletMeteredConfigEntry 3 }
|
|
|
|
rPDU2OutletMeteredConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID"
|
|
::= { rPDU2OutletMeteredConfigEntry 4 }
|
|
|
|
rPDU2OutletMeteredConfigLowLoadCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined low load outlet current threshold in Watts"
|
|
::= { rPDU2OutletMeteredConfigEntry 5 }
|
|
|
|
rPDU2OutletMeteredConfigNearOverloadCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined near outlet overload warning threshold
|
|
in Watts"
|
|
::= { rPDU2OutletMeteredConfigEntry 6 }
|
|
|
|
rPDU2OutletMeteredConfigOverloadCurrentThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined outlet overload current threshold in Watts"
|
|
::= { rPDU2OutletMeteredConfigEntry 7 }
|
|
|
|
-- rPDU2 Metered Outlet Properties
|
|
|
|
rPDU2OutletMeteredPropertiesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2OutletMeteredPropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU metered outlet properties"
|
|
::= { rPDU2OutletMetered 2 }
|
|
|
|
rPDU2OutletMeteredPropertiesEntry OBJECT-TYPE
|
|
SYNTAX RPDU2OutletMeteredPropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Properties of currently queried Rack PDU
|
|
metered outlet"
|
|
INDEX { rPDU2OutletMeteredPropertiesIndex }
|
|
::= { rPDU2OutletMeteredPropertiesTable 1 }
|
|
|
|
RPDU2OutletMeteredPropertiesEntry ::=
|
|
SEQUENCE {
|
|
rPDU2OutletMeteredPropertiesIndex INTEGER,
|
|
rPDU2OutletMeteredPropertiesModule INTEGER,
|
|
rPDU2OutletMeteredPropertiesName DisplayString,
|
|
rPDU2OutletMeteredPropertiesNumber INTEGER,
|
|
rPDU2OutletMeteredPropertiesLayout Rpdu2OutletPhaseLayoutType,
|
|
rPDU2OutletMeteredPropertiesPowerRating INTEGER,
|
|
rPDU2OutletMeteredPropertiesBank INTEGER
|
|
}
|
|
|
|
rPDU2OutletMeteredPropertiesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU metered properties table
|
|
entry"
|
|
::= { rPDU2OutletMeteredPropertiesEntry 1 }
|
|
|
|
rPDU2OutletMeteredPropertiesModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2OutletMeteredPropertiesEntry 2 }
|
|
|
|
rPDU2OutletMeteredPropertiesName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined metered outlet ID string"
|
|
::= { rPDU2OutletMeteredPropertiesEntry 3 }
|
|
|
|
rPDU2OutletMeteredPropertiesNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric metered outlet ID"
|
|
::= { rPDU2OutletMeteredPropertiesEntry 4 }
|
|
|
|
rPDU2OutletMeteredPropertiesLayout OBJECT-TYPE
|
|
SYNTAX Rpdu2OutletPhaseLayoutType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID describes the phase connections of
|
|
the referenced outlet as follows:
|
|
|
|
seqPhase1ToNeutral(1) indicates that the outlet is
|
|
wired from Phase 1 to Neutral.
|
|
|
|
seqPhase2ToNeutral(2) indicates that the outlet is
|
|
wired from Phase 2 to Neutral.
|
|
|
|
seqPhase3ToNeutral(3) indicates that the outlet is
|
|
wired from Phase 3 to Neutral.
|
|
|
|
seqPhase1ToPhase2(4) indicates that the outlet is
|
|
wired from Phase 1 to Phase 2.
|
|
|
|
seqPhase2ToPhase3(5) indicates that the outlet is
|
|
wired from Phase 2 to Phase 3.
|
|
|
|
seqPhase3ToPhase1(6) indicates that the outlet is
|
|
wired from Phase 3 to Phase 1."
|
|
::= { rPDU2OutletMeteredPropertiesEntry 5 }
|
|
|
|
rPDU2OutletMeteredPropertiesPowerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum power rating of Rack PDU metered outlet"
|
|
::= { rPDU2OutletMeteredPropertiesEntry 6 }
|
|
|
|
rPDU2OutletMeteredPropertiesBank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This outlet's numeric bank ID"
|
|
::= { rPDU2OutletMeteredPropertiesEntry 7 }
|
|
|
|
-- rPDU2 Metered Outlet Status
|
|
|
|
rPDU2OutletMeteredStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2OutletMeteredStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU metered outlet status data"
|
|
::= { rPDU2OutletMetered 3 }
|
|
|
|
rPDU2OutletMeteredStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDU2OutletMeteredStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status data from currently queried Rack PDU
|
|
metered outlet"
|
|
INDEX { rPDU2OutletMeteredStatusIndex }
|
|
::= { rPDU2OutletMeteredStatusTable 1 }
|
|
|
|
RPDU2OutletMeteredStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDU2OutletMeteredStatusIndex INTEGER,
|
|
rPDU2OutletMeteredStatusModule INTEGER,
|
|
rPDU2OutletMeteredStatusName DisplayString,
|
|
rPDU2OutletMeteredStatusNumber INTEGER,
|
|
rPDU2OutletMeteredStatusState INTEGER,
|
|
rPDU2OutletMeteredStatusCurrent INTEGER,
|
|
rPDU2OutletMeteredStatusPower INTEGER,
|
|
rPDU2OutletMeteredStatusPeakPower INTEGER,
|
|
rPDU2OutletMeteredStatusPeakPowerTimestamp DisplayString,
|
|
rPDU2OutletMeteredStatusPeakPowerStartTime DisplayString,
|
|
rPDU2OutletMeteredStatusEnergy INTEGER
|
|
}
|
|
|
|
rPDU2OutletMeteredStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU metered status table
|
|
entry"
|
|
::= { rPDU2OutletMeteredStatusEntry 1 }
|
|
|
|
rPDU2OutletMeteredStatusModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2OutletMeteredStatusEntry 2 }
|
|
|
|
rPDU2OutletMeteredStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined metered outlet ID string"
|
|
::= { rPDU2OutletMeteredStatusEntry 3 }
|
|
|
|
rPDU2OutletMeteredStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric metered outlet ID"
|
|
::= { rPDU2OutletMeteredStatusEntry 4 }
|
|
|
|
rPDU2OutletMeteredStatusState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lowLoad (1),
|
|
normal (2),
|
|
nearOverload (3),
|
|
overload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present load status of the Rack
|
|
PDU metered outlet being queried"
|
|
::= { rPDU2OutletMeteredStatusEntry 5 }
|
|
|
|
rPDU2OutletMeteredStatusCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the current draw, in tenths
|
|
of Amps, of the load on the Rack PDU
|
|
outlet being queried"
|
|
::= { rPDU2OutletMeteredStatusEntry 6 }
|
|
|
|
rPDU2OutletMeteredStatusPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power draw of the load
|
|
on the Rack PDU outlet being queried"
|
|
::= { rPDU2OutletMeteredStatusEntry 7 }
|
|
|
|
rPDU2OutletMeteredStatusPeakPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the peak power load draw
|
|
on the Rack PDU outlet being queried"
|
|
::= { rPDU2OutletMeteredStatusEntry 8 }
|
|
|
|
rPDU2OutletMeteredStatusPeakPowerTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time that this metered
|
|
outlet's peak power consumption occurred"
|
|
::= { rPDU2OutletMeteredStatusEntry 9 }
|
|
|
|
rPDU2OutletMeteredStatusPeakPowerStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the start date and time that this metered
|
|
outlet began recording peak power observations"
|
|
::= { rPDU2OutletMeteredStatusEntry 10 }
|
|
|
|
rPDU2OutletMeteredStatusEnergy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user resettable energy meter measuring Rack PDU load
|
|
energy consumption in tenths of kilowatt-hours"
|
|
::= { rPDU2OutletMeteredStatusEntry 11 }
|
|
|
|
-- rPDU2 Sensor Data
|
|
|
|
rPDU2Sensor OBJECT IDENTIFIER ::= { rPDU2 10 }
|
|
|
|
-- rPDU2 Temperature and Humidity Sensor Data
|
|
|
|
rPDU2SensorTempHumidityTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected temperature-humidity sensors"
|
|
::= { rPDU2Sensor 1}
|
|
|
|
rPDU2SensorTempHumidity OBJECT IDENTIFIER ::= { rPDU2Sensor 2 }
|
|
|
|
-- rPDU2 Temperature and Humidity Sensor Config
|
|
|
|
rPDU2SensorTempHumidityConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2SensorTempHumidityConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of temperature-humidity sensor
|
|
configuration data"
|
|
::= { rPDU2SensorTempHumidity 1 }
|
|
|
|
rPDU2SensorTempHumidityConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDU2SensorTempHumidityConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from temperature-humidity sensor
|
|
being queried"
|
|
INDEX { rPDU2SensorTempHumidityConfigIndex }
|
|
::= { rPDU2SensorTempHumidityConfigTable 1 }
|
|
|
|
RPDU2SensorTempHumidityConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDU2SensorTempHumidityConfigIndex INTEGER,
|
|
rPDU2SensorTempHumidityConfigModule INTEGER,
|
|
rPDU2SensorTempHumidityConfigName DisplayString,
|
|
rPDU2SensorTempHumidityConfigNumber INTEGER,
|
|
rPDU2SensorTempHumidityConfigTemperatureAlarmEnable INTEGER,
|
|
rPDU2SensorTempHumidityConfigHumidityAlarmEnable INTEGER,
|
|
rPDU2SensorTempHumidityConfigTempMaxThreshF INTEGER,
|
|
rPDU2SensorTempHumidityConfigTempHighThreshF INTEGER,
|
|
rPDU2SensorTempHumidityConfigTempHysteresisF INTEGER,
|
|
rPDU2SensorTempHumidityConfigTempMaxThreshC INTEGER,
|
|
rPDU2SensorTempHumidityConfigTempHighThreshC INTEGER,
|
|
rPDU2SensorTempHumidityConfigTempHysteresisC INTEGER,
|
|
rPDU2SensorTempHumidityConfigHumidityLowThresh INTEGER,
|
|
rPDU2SensorTempHumidityConfigHumidityMinThresh INTEGER,
|
|
rPDU2SensorTempHumidityConfigHumidityHysteresis INTEGER
|
|
}
|
|
|
|
rPDU2SensorTempHumidityConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the temperature-humidity sensor
|
|
configuration data table entry"
|
|
::= { rPDU2SensorTempHumidityConfigEntry 1 }
|
|
|
|
rPDU2SensorTempHumidityConfigModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2SensorTempHumidityConfigEntry 2 }
|
|
|
|
rPDU2SensorTempHumidityConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined temperature-humidity
|
|
sensor ID string"
|
|
::= { rPDU2SensorTempHumidityConfigEntry 3 }
|
|
|
|
rPDU2SensorTempHumidityConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature-humidity sensor numeric ID"
|
|
::= { rPDU2SensorTempHumidityConfigEntry 4 }
|
|
|
|
rPDU2SensorTempHumidityConfigTemperatureAlarmEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID enables or disables generation
|
|
of sensor temperature alarm.
|
|
|
|
Getting this OID returns the current value of
|
|
the temperature alarm enable."
|
|
::= { rPDU2SensorTempHumidityConfigEntry 5 }
|
|
|
|
rPDU2SensorTempHumidityConfigHumidityAlarmEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID enables or disables generation
|
|
of sensor humidity alarm.
|
|
|
|
Getting this OID returns the current value of
|
|
the humidity alarm enable."
|
|
::= { rPDU2SensorTempHumidityConfigEntry 6 }
|
|
|
|
rPDU2SensorTempHumidityConfigTempMaxThreshF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor maximum temperature alarm threshold in
|
|
Fahrenheit. Attempting to set this OID to a
|
|
value less than or equal to that of
|
|
rPDU2SensorTempHumidityConfigTempHighThreshF
|
|
will result in an error."
|
|
::= { rPDU2SensorTempHumidityConfigEntry 7 }
|
|
|
|
rPDU2SensorTempHumidityConfigTempHighThreshF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor high temperature warning alarm threshold
|
|
in Fahrenheit. Attempting to set this OID to a
|
|
value greater than or equal to that of
|
|
rPDU2SensorTempHumidityConfigTempMaxThreshF
|
|
will result in an error."
|
|
::= { rPDU2SensorTempHumidityConfigEntry 8 }
|
|
|
|
rPDU2SensorTempHumidityConfigTempHysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor temperature hysteresis setting in Fahrenheit"
|
|
::= { rPDU2SensorTempHumidityConfigEntry 9 }
|
|
|
|
rPDU2SensorTempHumidityConfigTempMaxThreshC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor maximum temperature alarm threshold
|
|
in Celsius. Attempting to set this OID to a
|
|
value less than or equal to that of
|
|
rPDU2SensorTempHumidityConfigTempHighThreshC
|
|
will result in an error."
|
|
::= { rPDU2SensorTempHumidityConfigEntry 10 }
|
|
|
|
rPDU2SensorTempHumidityConfigTempHighThreshC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor high temperature warning alarm threshold
|
|
in Celsius. Attempting to set this OID to a
|
|
value greater than or equal to that of
|
|
rPDU2SensorTempHumidityConfigTempMaxThreshC
|
|
will result in an error."
|
|
::= { rPDU2SensorTempHumidityConfigEntry 11 }
|
|
|
|
rPDU2SensorTempHumidityConfigTempHysteresisC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor temperature hysteresis setting in Celsius"
|
|
::= { rPDU2SensorTempHumidityConfigEntry 12 }
|
|
|
|
rPDU2SensorTempHumidityConfigHumidityLowThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor low humidity warning alarm threshold in percent
|
|
relative humidity. Attempting to set this OID to a
|
|
value less than or equal to that of
|
|
rPDU2SensorTempHumidityConfigHumidityMinThresh
|
|
will result in an error. Must be between 15% and 90%"
|
|
::= { rPDU2SensorTempHumidityConfigEntry 13 }
|
|
|
|
rPDU2SensorTempHumidityConfigHumidityMinThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor minimum humidity alarm threshold in percent
|
|
relative humidity. Attempting to set this OID to a
|
|
value greater than or equal to that of
|
|
rPDU2SensorTempHumidityConfigHumidityLowThresh
|
|
will result in an error. Must be between 15% and 90%"
|
|
::= { rPDU2SensorTempHumidityConfigEntry 14 }
|
|
|
|
rPDU2SensorTempHumidityConfigHumidityHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor humidity hysteresis setting in percent relative
|
|
humidity"
|
|
::= { rPDU2SensorTempHumidityConfigEntry 15 }
|
|
|
|
-- rPDU2 Temperature and Humidity Sensor Status
|
|
|
|
rPDU2SensorTempHumidityStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2SensorTempHumidityStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of temperature-humidity sensor status data"
|
|
::= { rPDU2SensorTempHumidity 2 }
|
|
|
|
rPDU2SensorTempHumidityStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDU2SensorTempHumidityStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status information from temperature-humidity sensor
|
|
being queried"
|
|
INDEX { rPDU2SensorTempHumidityStatusIndex }
|
|
::= { rPDU2SensorTempHumidityStatusTable 1 }
|
|
|
|
RPDU2SensorTempHumidityStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDU2SensorTempHumidityStatusIndex INTEGER,
|
|
rPDU2SensorTempHumidityStatusModule INTEGER,
|
|
rPDU2SensorTempHumidityStatusName DisplayString,
|
|
rPDU2SensorTempHumidityStatusNumber INTEGER,
|
|
rPDU2SensorTempHumidityStatusType INTEGER,
|
|
rPDU2SensorTempHumidityStatusCommStatus INTEGER,
|
|
rPDU2SensorTempHumidityStatusTempF INTEGER,
|
|
rPDU2SensorTempHumidityStatusTempC INTEGER,
|
|
rPDU2SensorTempHumidityStatusTempStatus INTEGER,
|
|
rPDU2SensorTempHumidityStatusRelativeHumidity INTEGER,
|
|
rPDU2SensorTempHumidityStatusHumidityStatus INTEGER
|
|
}
|
|
|
|
rPDU2SensorTempHumidityStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the temperature-humidity
|
|
status data table entry"
|
|
::= { rPDU2SensorTempHumidityStatusEntry 1 }
|
|
|
|
rPDU2SensorTempHumidityStatusModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2SensorTempHumidityStatusEntry 2 }
|
|
|
|
rPDU2SensorTempHumidityStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined temperature-humidity
|
|
sensor ID string"
|
|
::= { rPDU2SensorTempHumidityStatusEntry 3 }
|
|
|
|
rPDU2SensorTempHumidityStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature-humidity sensor numeric ID"
|
|
::= { rPDU2SensorTempHumidityStatusEntry 4 }
|
|
|
|
rPDU2SensorTempHumidityStatusType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temperatureOnly (1),
|
|
temperatureHumidity (2),
|
|
commsLost (3),
|
|
notInstalled (4)
|
|
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the sensor"
|
|
::= { rPDU2SensorTempHumidityStatusEntry 5 }
|
|
|
|
rPDU2SensorTempHumidityStatusCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notInstalled (1),
|
|
commsOK (2),
|
|
commsLost (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The communications status of the sensor"
|
|
::= { rPDU2SensorTempHumidityStatusEntry 6 }
|
|
|
|
rPDU2SensorTempHumidityStatusTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor temperature reading in tenths of degrees Fahrenheit"
|
|
::= { rPDU2SensorTempHumidityStatusEntry 7 }
|
|
|
|
rPDU2SensorTempHumidityStatusTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor temperature reading in tenths of degrees Celsius"
|
|
::= { rPDU2SensorTempHumidityStatusEntry 8 }
|
|
|
|
rPDU2SensorTempHumidityStatusTempStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
belowMin (2),
|
|
belowLow (3),
|
|
normal (4),
|
|
aboveHigh (5),
|
|
aboveMax (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID reports the current state of the temperature probe.
|
|
|
|
A notPresent (1) response indicates that no probe is attached.
|
|
A belowMin (2) response indicates that the probe is present and
|
|
its measured temperature lies below the minimum threshold.
|
|
A belowLow (3) response indicates that the probe is present and
|
|
its measured temperature lies below the low threshold.
|
|
A normal (4) response indicates that the probe is present
|
|
and its measured temperature lies within all temperature thresholds.
|
|
An aboveHigh (5) response indicates that the probe is present
|
|
and is measuring a temperature above the high threshold.
|
|
An aboveMax (6) response indicates that the probe is present
|
|
and is measuring a temperature above the max threshold."
|
|
::= { rPDU2SensorTempHumidityStatusEntry 9 }
|
|
|
|
rPDU2SensorTempHumidityStatusRelativeHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor humidity reading in percent relative humidity"
|
|
::= { rPDU2SensorTempHumidityStatusEntry 10 }
|
|
|
|
rPDU2SensorTempHumidityStatusHumidityStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
belowMin (2),
|
|
belowLow (3),
|
|
normal (4),
|
|
aboveHigh (5),
|
|
aboveMax (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID reports the current state of the humidity probe.
|
|
|
|
A notPresent (1) response indicates that no probe is attached.
|
|
A belowMin (2) response indicates that the probe is present and
|
|
its measured humidity lies below the minimum threshold.
|
|
A belowLow (3) response indicates that the probe is present and
|
|
its measured humidity lies below the low threshold.
|
|
A normal (4) response indicates that the probe is present
|
|
and its measured humidity lies within all humidity thresholds.
|
|
An aboveHigh (5) response indicates that the probe is present
|
|
and is measuring a humidity above the high threshold.
|
|
An aboveMax (6) response indicates that the probe is present
|
|
and is measuring a humidity above the max threshold."
|
|
::= { rPDU2SensorTempHumidityStatusEntry 11 }
|
|
|
|
-- rPDU2 Discrete Sensor Data
|
|
|
|
rPDU2SensorDiscreteTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected discrete sensors"
|
|
::= { rPDU2Sensor 3}
|
|
|
|
rPDU2SensorDiscrete OBJECT IDENTIFIER ::= { rPDU2Sensor 4 }
|
|
|
|
-- rPDU2 Discrete Sensor Config
|
|
|
|
rPDU2SensorDiscreteConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2SensorDiscreteConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of discrete sensor configuration
|
|
data"
|
|
::= { rPDU2SensorDiscrete 1 }
|
|
|
|
rPDU2SensorDiscreteConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDU2SensorDiscreteConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from discreste sensor
|
|
being queried"
|
|
INDEX { rPDU2SensorDiscreteConfigIndex }
|
|
::= { rPDU2SensorDiscreteConfigTable 1 }
|
|
|
|
RPDU2SensorDiscreteConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDU2SensorDiscreteConfigIndex INTEGER,
|
|
rPDU2SensorDiscreteConfigModule INTEGER,
|
|
rPDU2SensorDiscreteConfigName DisplayString,
|
|
rPDU2SensorDiscreteConfigNumber INTEGER,
|
|
rPDU2SensorDiscreteConfigNormalState INTEGER,
|
|
rPDU2SensorDiscreteConfigAbnormalSeverity INTEGER
|
|
}
|
|
|
|
rPDU2SensorDiscreteConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the discrete sensor configuration
|
|
data table entry"
|
|
::= { rPDU2SensorDiscreteConfigEntry 1 }
|
|
|
|
rPDU2SensorDiscreteConfigModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2SensorDiscreteConfigEntry 2 }
|
|
|
|
rPDU2SensorDiscreteConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined discrete sensor ID string"
|
|
::= { rPDU2SensorDiscreteConfigEntry 3 }
|
|
|
|
rPDU2SensorDiscreteConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The discrete sensor numeric ID"
|
|
::= { rPDU2SensorDiscreteConfigEntry 4 }
|
|
|
|
rPDU2SensorDiscreteConfigNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyOpen (1),
|
|
normallyClosed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the normal state of the discrete input
|
|
contact"
|
|
::= { rPDU2SensorDiscreteConfigEntry 5 }
|
|
|
|
rPDU2SensorDiscreteConfigAbnormalSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
informational (1),
|
|
warning (2),
|
|
critical (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the severity of alarm triggered by
|
|
abnormal discrete input contact state"
|
|
::= { rPDU2SensorDiscreteConfigEntry 6 }
|
|
|
|
-- rPDU2 Discrete Sensor Status
|
|
|
|
rPDU2SensorDiscreteStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2SensorDiscreteStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of discrete sensor status data"
|
|
::= { rPDU2SensorDiscrete 2 }
|
|
|
|
rPDU2SensorDiscreteStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDU2SensorDiscreteStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status information from discrete sensor
|
|
being queried"
|
|
INDEX { rPDU2SensorDiscreteStatusIndex }
|
|
::= { rPDU2SensorDiscreteStatusTable 1 }
|
|
|
|
RPDU2SensorDiscreteStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDU2SensorDiscreteStatusIndex INTEGER,
|
|
rPDU2SensorDiscreteStatusModule INTEGER,
|
|
rPDU2SensorDiscreteStatusName DisplayString,
|
|
rPDU2SensorDiscreteStatusNumber INTEGER,
|
|
rPDU2SensorDiscreteStatusType INTEGER,
|
|
rPDU2SensorDiscreteStatusCommStatus INTEGER,
|
|
rPDU2SensorDiscreteStatusCurrentState INTEGER,
|
|
rPDU2SensorDiscreteStatusAlarmState INTEGER
|
|
}
|
|
|
|
rPDU2SensorDiscreteStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the discrete sensor status data
|
|
table entry"
|
|
::= { rPDU2SensorDiscreteStatusEntry 1 }
|
|
|
|
rPDU2SensorDiscreteStatusModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2SensorDiscreteStatusEntry 2 }
|
|
|
|
rPDU2SensorDiscreteStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined discrete sensor ID string"
|
|
::= { rPDU2SensorDiscreteStatusEntry 3 }
|
|
|
|
rPDU2SensorDiscreteStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The discrete sensor numeric ID"
|
|
::= { rPDU2SensorDiscreteStatusEntry 4 }
|
|
|
|
rPDU2SensorDiscreteStatusType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notConnected (1),
|
|
doorContactSensor (2),
|
|
smokeSensor (3),
|
|
motionDetector (4),
|
|
vibrationSensor (5),
|
|
dryContactSensor (6),
|
|
spotLeakSensor (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of discrete sensor currently being queried"
|
|
::= { rPDU2SensorDiscreteStatusEntry 5 }
|
|
|
|
rPDU2SensorDiscreteStatusCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notInstalled(1),
|
|
commsOK(2),
|
|
commsLost(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The communications status of the sensor"
|
|
::= { rPDU2SensorDiscreteStatusEntry 6 }
|
|
|
|
rPDU2SensorDiscreteStatusCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current open/close state of the discrete
|
|
sensor"
|
|
::= { rPDU2SensorDiscreteStatusEntry 7 }
|
|
|
|
rPDU2SensorDiscreteStatusAlarmState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates alarm status of discrete sensor input"
|
|
::= { rPDU2SensorDiscreteStatusEntry 8 }
|
|
|
|
rPDU2Group OBJECT IDENTIFIER ::= { rPDU2 11 }
|
|
|
|
-- rPDU2 Total Rack PDU Network Port Sharing (NPS) group power and energy
|
|
|
|
rPDU2GroupNumberOfDevices OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the number of Rack PDU devices contributing
|
|
to the Network Port Sharing (NPS) group power and energy values.
|
|
Queries to guest units in an NPS group are not applicable and will
|
|
return 0."
|
|
|
|
::= { rPDU2Group 1 }
|
|
|
|
rPDU2GroupTotalPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the total power consumption of the Rack PDU
|
|
Network Port Sharing (NPS) group devices in hundredths of kilowatts.
|
|
Queries to guest units in an NPS group are not applicable and will
|
|
return 0."
|
|
|
|
::= { rPDU2Group 2 }
|
|
|
|
rPDU2GroupTotalEnergy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the total energy consumption of the Rack PDU
|
|
Network Port Sharing (NPS) group devices in tenths of kilowatt-hours.
|
|
|
|
To reset the energy meters for each of the Rack PDU devices that contribute
|
|
to this value, see the rPDU2GroupEnergyReset OID.
|
|
|
|
To view the start time for each of the Rack PDU device energy meters that
|
|
contribute to this value, see the rPDU2DeviceStatusEnergyStartTime OID.
|
|
|
|
Queries to guest units in an NPS group are not applicable and will
|
|
return 0."
|
|
|
|
::= { rPDU2Group 3 }
|
|
|
|
rPDU2GroupEnergyReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2),
|
|
notSupported (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the device energy meter value
|
|
on each device in the Rack PDU Network Port Sharing (NPS) group to be
|
|
reset to zero.
|
|
|
|
Each device in the Rack PDU group will also have its corresponding
|
|
rPDU2DeviceStatusEnergyStartTime OID value updated.
|
|
|
|
Getting this OID in models that support this feature will do nothing
|
|
and return the noOperation(1) value.
|
|
|
|
Models that do not support this feature, as well as guest units in an
|
|
NPS group, will respond to this OID with a value of notSupported (3).
|
|
Attempts to set this OID in these units will fail."
|
|
|
|
::= { rPDU2Group 4 }
|
|
|
|
|
|
-- rPDU2 Phase To Phase Status
|
|
rPDU2PhaseToPhaseStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected Rack PDU banks"
|
|
::= { rPDU2 12}
|
|
|
|
rPDU2PhaseToPhase OBJECT IDENTIFIER ::= { rPDU2 13 }
|
|
|
|
rPDU2PhaseToPhaseStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDU2PhaseToPhaseStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU phase to phase status data.
|
|
This table is only applicable to SKUs that have
|
|
phase to phase outputs."
|
|
::= { rPDU2PhaseToPhase 1 }
|
|
|
|
rPDU2PhaseToPhaseStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDU2PhaseToPhaseStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status data from currently queried Rack PDU
|
|
phase to phase outputs"
|
|
INDEX { rPDU2PhaseToPhaseStatusIndex }
|
|
::= { rPDU2PhaseToPhaseStatusTable 1 }
|
|
|
|
RPDU2PhaseToPhaseStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDU2PhaseToPhaseStatusIndex INTEGER,
|
|
rPDU2PhaseToPhaseStatusModule INTEGER,
|
|
rPDU2PhaseToPhaseStatusVoltage1to2 INTEGER,
|
|
rPDU2PhaseToPhaseStatusVoltage2to3 INTEGER,
|
|
rPDU2PhaseToPhaseStatusVoltage3to1 INTEGER
|
|
}
|
|
|
|
rPDU2PhaseToPhaseStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase to phase status table
|
|
entry"
|
|
::= { rPDU2PhaseToPhaseStatusEntry 1 }
|
|
|
|
rPDU2PhaseToPhaseStatusModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID"
|
|
::= { rPDU2PhaseToPhaseStatusEntry 2 }
|
|
|
|
|
|
rPDU2PhaseToPhaseStatusVoltage1to2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Voltage, in Volts, of the Rack
|
|
PDU phase 1 to phase 2 output being queried"
|
|
::= { rPDU2PhaseToPhaseStatusEntry 3 }
|
|
|
|
rPDU2PhaseToPhaseStatusVoltage2to3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Voltage, in Volts, of the Rack
|
|
PDU phase 2 to phase 3 output being queried"
|
|
::= { rPDU2PhaseToPhaseStatusEntry 4 }
|
|
|
|
rPDU2PhaseToPhaseStatusVoltage3to1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Voltage, in Volts, of the Rack
|
|
PDU phase 3 to phase 2 output being queried"
|
|
::= { rPDU2PhaseToPhaseStatusEntry 5 }
|
|
|
|
|
|
|
|
-- the cooling group
|
|
|
|
coolingUnit OBJECT IDENTIFIER ::= { cooling 1 }
|
|
|
|
coolingUnitTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of cooling units accessible via this agent."
|
|
::= { coolingUnit 1 }
|
|
|
|
coolingUnitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CoolingUnitEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of cooling unit level data."
|
|
::= { coolingUnit 2}
|
|
|
|
coolingUnitEntry OBJECT-TYPE
|
|
SYNTAX CoolingUnitEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An element of coolingUnitTable."
|
|
INDEX { coolingUnitTableIndex }
|
|
::= { coolingUnitTable 1 }
|
|
|
|
CoolingUnitEntry ::= SEQUENCE {
|
|
coolingUnitTableIndex INTEGER
|
|
}
|
|
|
|
coolingUnitTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit reference identifier for this table and all other table entries subordinate to coolingUnits."
|
|
::= { coolingUnitEntry 1 }
|
|
|
|
coolingUnitAbout OBJECT IDENTIFIER ::= { coolingUnit 3 }
|
|
|
|
coolingUnitAboutTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The potential number of entries available in coolingUnitAboutTable."
|
|
::= { coolingUnitAbout 1 }
|
|
|
|
coolingUnitAboutTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CoolingUnitAboutEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of unit reference information."
|
|
::= { coolingUnitAbout 2}
|
|
|
|
coolingUnitAboutEntry OBJECT-TYPE
|
|
SYNTAX CoolingUnitAboutEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An element of coolingUnitAboutTable."
|
|
INDEX { coolingUnitTableIndex,
|
|
coolingUnitAboutTableIndex }
|
|
::= { coolingUnitAboutTable 1 }
|
|
|
|
CoolingUnitAboutEntry ::= SEQUENCE {
|
|
coolingUnitAboutTableIndex INTEGER,
|
|
coolingUnitAboutDescription DisplayString,
|
|
coolingUnitAboutValue DisplayString
|
|
}
|
|
|
|
coolingUnitAboutTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The static reference identifier for each table entry."
|
|
::= { coolingUnitAboutEntry 1 }
|
|
|
|
coolingUnitAboutDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the information presented in coolingUnitAboutValue."
|
|
::= { coolingUnitAboutEntry 2 }
|
|
|
|
coolingUnitAboutValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual value of the current table entry."
|
|
::= { coolingUnitAboutEntry 3 }
|
|
|
|
coolingUnitStatus OBJECT IDENTIFIER ::= { coolingUnit 4 }
|
|
coolingUnitStatusAnalog OBJECT IDENTIFIER ::= { coolingUnitStatus 1 }
|
|
|
|
coolingUnitStatusAnalogTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The potential number of entries available in coolingUnitStatusAnalogTable."
|
|
::= { coolingUnitStatusAnalog 1 }
|
|
|
|
coolingUnitStatusAnalogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CoolingUnitStatusAnalogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of analog unit status data."
|
|
::= { coolingUnitStatusAnalog 2}
|
|
|
|
coolingUnitStatusAnalogEntry OBJECT-TYPE
|
|
SYNTAX CoolingUnitStatusAnalogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An element of coolingUnitStatusAnalogTable."
|
|
INDEX { coolingUnitTableIndex,
|
|
coolingUnitStatusAnalogTableIndex }
|
|
::= { coolingUnitStatusAnalogTable 1 }
|
|
|
|
CoolingUnitStatusAnalogEntry ::= SEQUENCE {
|
|
coolingUnitStatusAnalogTableIndex INTEGER,
|
|
coolingUnitStatusAnalogDescription DisplayString,
|
|
coolingUnitStatusAnalogValue INTEGER,
|
|
coolingUnitStatusAnalogUnits DisplayString,
|
|
coolingUnitStatusAnalogScale INTEGER
|
|
}
|
|
|
|
coolingUnitStatusAnalogTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The static reference identifier for each table entry."
|
|
::= { coolingUnitStatusAnalogEntry 1 }
|
|
|
|
coolingUnitStatusAnalogDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the information presented in coolingUnitStatusAnalogValue."
|
|
::= { coolingUnitStatusAnalogEntry 2 }
|
|
|
|
coolingUnitStatusAnalogValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The scaled value of the current table entry (multiplied by coolingUnitStatusAnalogScale for integer presentation)."
|
|
::= { coolingUnitStatusAnalogEntry 3 }
|
|
|
|
coolingUnitStatusAnalogUnits OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit of measure by which coolingUnitStatusAnalogValue is expressed."
|
|
::= { coolingUnitStatusAnalogEntry 4 }
|
|
|
|
coolingUnitStatusAnalogScale OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The factor by which coolingUnitStatusAnalogValue is expressed."
|
|
::= { coolingUnitStatusAnalogEntry 5 }
|
|
|
|
coolingUnitStatusDiscrete OBJECT IDENTIFIER ::= { coolingUnitStatus 2 }
|
|
|
|
coolingUnitStatusDiscreteTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The potential number of entries available in coolingUnitStatusDiscreteTable."
|
|
::= { coolingUnitStatusDiscrete 1 }
|
|
|
|
coolingUnitStatusDiscreteTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CoolingUnitStatusDiscreteEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of discrete unit status data."
|
|
::= { coolingUnitStatusDiscrete 2}
|
|
|
|
coolingUnitStatusDiscreteEntry OBJECT-TYPE
|
|
SYNTAX CoolingUnitStatusDiscreteEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An element of coolingUnitStatusDiscreteTable."
|
|
INDEX { coolingUnitTableIndex,
|
|
coolingUnitStatusDiscreteTableIndex }
|
|
::= { coolingUnitStatusDiscreteTable 1 }
|
|
|
|
CoolingUnitStatusDiscreteEntry ::= SEQUENCE {
|
|
coolingUnitStatusDiscreteTableIndex INTEGER,
|
|
coolingUnitStatusDiscreteDescription DisplayString,
|
|
coolingUnitStatusDiscreteValueAsString DisplayString,
|
|
coolingUnitStatusDiscreteValueAsInteger INTEGER,
|
|
coolingUnitStatusDiscreteIntegerReferenceKey DisplayString
|
|
}
|
|
|
|
coolingUnitStatusDiscreteTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The static reference identifier for each table entry."
|
|
::= { coolingUnitStatusDiscreteEntry 1 }
|
|
|
|
coolingUnitStatusDiscreteDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the information presented in this table's 'value' OIDs."
|
|
::= { coolingUnitStatusDiscreteEntry 2 }
|
|
|
|
coolingUnitStatusDiscreteValueAsString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual value of the current table entry expressed as a string."
|
|
::= { coolingUnitStatusDiscreteEntry 3 }
|
|
|
|
coolingUnitStatusDiscreteValueAsInteger OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual value of the current table entry expressed as an integer value."
|
|
::= { coolingUnitStatusDiscreteEntry 4 }
|
|
|
|
coolingUnitStatusDiscreteIntegerReferenceKey OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A complete listing of all possible coolingUnitStatusDiscreteValueAsInteger values paired with their identifying strings."
|
|
::= { coolingUnitStatusDiscreteEntry 5 }
|
|
|
|
coolingUnitConfiguration OBJECT IDENTIFIER ::= { coolingUnit 5 }
|
|
coolingUnitConfigurationAnalog OBJECT IDENTIFIER ::= { coolingUnitConfiguration 1 }
|
|
|
|
coolingUnitConfigurationAnalogTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The potential number of entries available in coolingUnitConfigurationAnalogTable."
|
|
::= { coolingUnitConfigurationAnalog 1 }
|
|
|
|
coolingUnitConfigurationAnalogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CoolingUnitConfigurationAnalogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of analog unit configuration data."
|
|
::= { coolingUnitConfigurationAnalog 2}
|
|
|
|
coolingUnitConfigurationAnalogEntry OBJECT-TYPE
|
|
SYNTAX CoolingUnitConfigurationAnalogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An element of coolingUnitConfigurationAnalogTable."
|
|
INDEX { coolingUnitTableIndex,
|
|
coolingUnitConfigurationAnalogTableIndex }
|
|
::= { coolingUnitConfigurationAnalogTable 1 }
|
|
|
|
CoolingUnitConfigurationAnalogEntry ::= SEQUENCE {
|
|
coolingUnitConfigurationAnalogTableIndex INTEGER,
|
|
coolingUnitConfigurationAnalogDescription DisplayString,
|
|
coolingUnitConfigurationAnalogValue INTEGER,
|
|
coolingUnitConfigurationAnalogUnits DisplayString,
|
|
coolingUnitConfigurationAnalogScale INTEGER,
|
|
coolingUnitConfigurationAnalogAccess INTEGER,
|
|
coolingUnitConfigurationAnalogMinimum INTEGER,
|
|
coolingUnitConfigurationAnalogMaximum INTEGER
|
|
}
|
|
|
|
coolingUnitConfigurationAnalogTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The static reference identifier for each table entry."
|
|
::= { coolingUnitConfigurationAnalogEntry 1 }
|
|
|
|
coolingUnitConfigurationAnalogDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the information presented in coolingUnitConfigurationAnalogValue."
|
|
::= { coolingUnitConfigurationAnalogEntry 2 }
|
|
|
|
coolingUnitConfigurationAnalogValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The scaled value of the current table entry (multiplied by coolingUnitConfigurationAnalogScale for integer presentation)."
|
|
::= { coolingUnitConfigurationAnalogEntry 3 }
|
|
|
|
coolingUnitConfigurationAnalogUnits OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit of measure by which coolingUnitConfigurationAnalogValue is expressed."
|
|
::= { coolingUnitConfigurationAnalogEntry 4 }
|
|
|
|
coolingUnitConfigurationAnalogScale OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The factor by which coolingUnitConfigurationAnalogValue is expressed."
|
|
::= { coolingUnitConfigurationAnalogEntry 5 }
|
|
|
|
coolingUnitConfigurationAnalogAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
readOnly (1),
|
|
readWrite (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A description of available access to coolingUnitConfigurationAnalogValue via SNMP client."
|
|
::= { coolingUnitConfigurationAnalogEntry 6 }
|
|
|
|
coolingUnitConfigurationAnalogMinimum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum possible value of coolingUnitConfigurationAnalogValue."
|
|
::= { coolingUnitConfigurationAnalogEntry 7 }
|
|
|
|
coolingUnitConfigurationAnalogMaximum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum possible value of coolingUnitConfigurationAnalogValue."
|
|
::= { coolingUnitConfigurationAnalogEntry 8 }
|
|
|
|
coolingUnitConfigurationDiscrete OBJECT IDENTIFIER ::= { coolingUnitConfiguration 2 }
|
|
|
|
coolingUnitConfigurationDiscreteTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The potential number of entries available in coolingUnitConfigurationDiscreteTable."
|
|
::= { coolingUnitConfigurationDiscrete 1 }
|
|
|
|
coolingUnitConfigurationDiscreteTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CoolingUnitConfigurationDiscreteEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of discrete unit configuration data."
|
|
::= { coolingUnitConfigurationDiscrete 2}
|
|
|
|
coolingUnitConfigurationDiscreteEntry OBJECT-TYPE
|
|
SYNTAX CoolingUnitConfigurationDiscreteEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An element of coolingUnitConfigurationDiscreteTable."
|
|
INDEX { coolingUnitTableIndex,
|
|
coolingUnitConfigurationDiscreteTableIndex }
|
|
::= { coolingUnitConfigurationDiscreteTable 1 }
|
|
|
|
CoolingUnitConfigurationDiscreteEntry ::= SEQUENCE {
|
|
coolingUnitConfigurationDiscreteTableIndex INTEGER,
|
|
coolingUnitConfigurationDiscreteDescription DisplayString,
|
|
coolingUnitConfigurationDiscreteValueAsString DisplayString,
|
|
coolingUnitConfigurationDiscreteValueAsInteger INTEGER,
|
|
coolingUnitConfigurationDiscreteIntegerReferenceKey DisplayString,
|
|
coolingUnitConfigurationDiscreteAccess INTEGER
|
|
}
|
|
|
|
coolingUnitConfigurationDiscreteTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The static reference identifier for each table entry."
|
|
::= { coolingUnitConfigurationDiscreteEntry 1 }
|
|
|
|
coolingUnitConfigurationDiscreteDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the information presented in this table's 'value' OIDs."
|
|
::= { coolingUnitConfigurationDiscreteEntry 2 }
|
|
|
|
coolingUnitConfigurationDiscreteValueAsString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual value of the current table entry expressed as a string."
|
|
::= { coolingUnitConfigurationDiscreteEntry 3 }
|
|
|
|
coolingUnitConfigurationDiscreteValueAsInteger OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual value of the current table entry expressed as an integer value."
|
|
::= { coolingUnitConfigurationDiscreteEntry 4 }
|
|
|
|
coolingUnitConfigurationDiscreteIntegerReferenceKey OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A complete listing of all possible coolingUnitConfigurationDiscreteValueAsInteger values paired with their identifying strings."
|
|
::= { coolingUnitConfigurationDiscreteEntry 5 }
|
|
|
|
coolingUnitConfigurationDiscreteAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
readOnly (1),
|
|
readWrite (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A description of available access to coolingUnitConfigurationDiscreteValueAsInteger via SNMP client."
|
|
::= { coolingUnitConfigurationDiscreteEntry 6 }
|
|
|
|
coolingUnitConfigurationString OBJECT IDENTIFIER ::= { coolingUnitConfiguration 3 }
|
|
|
|
coolingUnitConfigurationStringTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The potential number of entries available in coolingUnitConfigurationStringTable."
|
|
::= { coolingUnitConfigurationString 1 }
|
|
|
|
coolingUnitConfigurationStringTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CoolingUnitConfigurationStringEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of unit configuration strings."
|
|
::= { coolingUnitConfigurationString 2}
|
|
|
|
coolingUnitConfigurationStringEntry OBJECT-TYPE
|
|
SYNTAX CoolingUnitConfigurationStringEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An element of coolingUnitConfigurationStringTable."
|
|
INDEX { coolingUnitTableIndex,
|
|
coolingUnitConfigurationStringTableIndex }
|
|
::= { coolingUnitConfigurationStringTable 1 }
|
|
|
|
CoolingUnitConfigurationStringEntry ::= SEQUENCE {
|
|
coolingUnitConfigurationStringTableIndex INTEGER,
|
|
coolingUnitConfigurationStringDescription DisplayString,
|
|
coolingUnitConfigurationStringValue DisplayString,
|
|
coolingUnitConfigurationStringMaxLength INTEGER,
|
|
coolingUnitConfigurationStringAccess INTEGER
|
|
}
|
|
|
|
coolingUnitConfigurationStringTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The static reference identifier for each table entry."
|
|
::= { coolingUnitConfigurationStringEntry 1 }
|
|
|
|
coolingUnitConfigurationStringDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the information presented in coolingUnitConfigurationStringValue."
|
|
::= { coolingUnitConfigurationStringEntry 2 }
|
|
|
|
coolingUnitConfigurationStringValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual value of the current table entry."
|
|
::= { coolingUnitConfigurationStringEntry 3 }
|
|
|
|
coolingUnitConfigurationStringMaxLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum string length supported by coolingUnitConfigurationStringValue."
|
|
::= { coolingUnitConfigurationStringEntry 4 }
|
|
|
|
coolingUnitConfigurationStringAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
readOnly (1),
|
|
readWrite (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A description of available access to coolingUnitConfigurationStringValue via SNMP client."
|
|
::= { coolingUnitConfigurationStringEntry 5 }
|
|
|
|
coolingUnitExtended OBJECT IDENTIFIER ::= { coolingUnit 6 }
|
|
coolingUnitExtendedAnalog OBJECT IDENTIFIER ::= { coolingUnitExtended 1 }
|
|
|
|
coolingUnitExtendedAnalogTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The potential number of entries available in coolingUnitExtendedAnalogTable."
|
|
::= { coolingUnitExtendedAnalog 1 }
|
|
|
|
coolingUnitExtendedAnalogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CoolingUnitExtendedAnalogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of secondary analog data for the cooling unit or one of its components."
|
|
::= { coolingUnitExtendedAnalog 2}
|
|
|
|
coolingUnitExtendedAnalogEntry OBJECT-TYPE
|
|
SYNTAX CoolingUnitExtendedAnalogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An element of coolingUnitExtendedAnalogTable."
|
|
INDEX { coolingUnitTableIndex,
|
|
coolingUnitExtendedAnalogTableIndex }
|
|
::= { coolingUnitExtendedAnalogTable 1 }
|
|
|
|
CoolingUnitExtendedAnalogEntry ::= SEQUENCE {
|
|
coolingUnitExtendedAnalogTableIndex INTEGER,
|
|
coolingUnitExtendedAnalogDescription DisplayString,
|
|
coolingUnitExtendedAnalogValue INTEGER,
|
|
coolingUnitExtendedAnalogUnits DisplayString,
|
|
coolingUnitExtendedAnalogScale INTEGER
|
|
}
|
|
|
|
coolingUnitExtendedAnalogTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The static reference identifier for each table entry. This identifier may reference different table entries in different unit models."
|
|
::= { coolingUnitExtendedAnalogEntry 1 }
|
|
|
|
coolingUnitExtendedAnalogDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the information presented in coolingUnitExtendedAnalogValue."
|
|
::= { coolingUnitExtendedAnalogEntry 2 }
|
|
|
|
coolingUnitExtendedAnalogValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The scaled value of the current table entry (multiplied by coolingUnitExtendedAnalogScale for integer presentation)."
|
|
::= { coolingUnitExtendedAnalogEntry 3 }
|
|
|
|
coolingUnitExtendedAnalogUnits OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit of measure by which coolingUnitExtendedAnalogValue is expressed."
|
|
::= { coolingUnitExtendedAnalogEntry 4 }
|
|
|
|
coolingUnitExtendedAnalogScale OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The factor by which coolingUnitExtendedAnalogValue is expressed."
|
|
::= { coolingUnitExtendedAnalogEntry 5 }
|
|
|
|
coolingUnitExtendedDiscrete OBJECT IDENTIFIER ::= { coolingUnitExtended 2 }
|
|
|
|
coolingUnitExtendedDiscreteTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The potential number of entries available in coolingUnitExtendedDiscreteTable."
|
|
::= { coolingUnitExtendedDiscrete 1 }
|
|
|
|
coolingUnitExtendedDiscreteTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CoolingUnitExtendedDiscreteEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of secondary discrete cooling unit data."
|
|
::= { coolingUnitExtendedDiscrete 2}
|
|
|
|
coolingUnitExtendedDiscreteEntry OBJECT-TYPE
|
|
SYNTAX CoolingUnitExtendedDiscreteEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An element of coolingUnitExtendedDiscreteTable."
|
|
INDEX { coolingUnitTableIndex,
|
|
coolingUnitExtendedDiscreteTableIndex }
|
|
::= { coolingUnitExtendedDiscreteTable 1 }
|
|
|
|
CoolingUnitExtendedDiscreteEntry ::= SEQUENCE {
|
|
coolingUnitExtendedDiscreteTableIndex INTEGER,
|
|
coolingUnitExtendedDiscreteDescription DisplayString,
|
|
coolingUnitExtendedDiscreteValueAsString DisplayString,
|
|
coolingUnitExtendedDiscreteValueAsInteger INTEGER,
|
|
coolingUnitExtendedDiscreteIntegerReferenceKey DisplayString
|
|
}
|
|
|
|
coolingUnitExtendedDiscreteTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The static reference identifier for each table entry. This identifier may reference different table entries in different unit models."
|
|
::= { coolingUnitExtendedDiscreteEntry 1 }
|
|
|
|
coolingUnitExtendedDiscreteDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the information presented in this table's 'value' OIDs."
|
|
::= { coolingUnitExtendedDiscreteEntry 2 }
|
|
|
|
coolingUnitExtendedDiscreteValueAsString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual value of the current table entry expressed as a string."
|
|
::= { coolingUnitExtendedDiscreteEntry 3 }
|
|
|
|
coolingUnitExtendedDiscreteValueAsInteger OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual value of the current table entry expressed as an integer value."
|
|
::= { coolingUnitExtendedDiscreteEntry 4 }
|
|
|
|
coolingUnitExtendedDiscreteIntegerReferenceKey OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A complete listing of all possible coolingUnitExtendedDiscreteValueAsInteger values paired with their identifying strings."
|
|
::= { coolingUnitExtendedDiscreteEntry 5 }
|
|
|
|
coolingUnitExtendedString OBJECT IDENTIFIER ::= { coolingUnitExtended 3 }
|
|
|
|
coolingUnitExtendedStringTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The potential number of entries available in coolingUnitExtendedStringTable."
|
|
::= { coolingUnitExtendedString 1 }
|
|
|
|
coolingUnitExtendedStringTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CoolingUnitExtendedStringEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of secondary unit reference data."
|
|
::= { coolingUnitExtendedString 2}
|
|
|
|
coolingUnitExtendedStringEntry OBJECT-TYPE
|
|
SYNTAX CoolingUnitExtendedStringEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An element of coolingUnitExtendedStringTable."
|
|
INDEX { coolingUnitTableIndex,
|
|
coolingUnitExtendedStringTableIndex }
|
|
::= { coolingUnitExtendedStringTable 1 }
|
|
|
|
CoolingUnitExtendedStringEntry ::= SEQUENCE {
|
|
coolingUnitExtendedStringTableIndex INTEGER,
|
|
coolingUnitExtendedStringDescription DisplayString,
|
|
coolingUnitExtendedStringValue DisplayString
|
|
}
|
|
|
|
coolingUnitExtendedStringTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The static reference identifier for each table entry. This identifier may reference different table entries in different unit models."
|
|
::= { coolingUnitExtendedStringEntry 1 }
|
|
|
|
coolingUnitExtendedStringDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the information presented in coolingUnitExtendedStringValue."
|
|
::= { coolingUnitExtendedStringEntry 2 }
|
|
|
|
coolingUnitExtendedStringValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual value of the current table entry."
|
|
::= { coolingUnitExtendedStringEntry 3 }
|
|
|
|
|
|
|
|
-- the dm3IdentSystem group
|
|
|
|
dm3IdentSysDescriptionTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC description records."
|
|
::= { dm3IdentSystem 1 }
|
|
|
|
dm3IdentSysDescriptionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3IdentSysDescriptionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing description records of the powerplant. The number of
|
|
entries is contained in the dm3IdentSysDescriptionTableSize OID."
|
|
::= { dm3IdentSystem 2 }
|
|
|
|
dm3IdentSysDescriptionEntry OBJECT-TYPE
|
|
SYNTAX Dm3IdentSysDescriptionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The powerplant description record to reference."
|
|
INDEX { dm3IdentSysDescriptionIndex }
|
|
::= { dm3IdentSysDescriptionTable 1 }
|
|
|
|
Dm3IdentSysDescriptionEntry ::=
|
|
SEQUENCE {
|
|
dm3IdentSysDescriptionIndex INTEGER,
|
|
dm3IdentSysDescriptionText DisplayString
|
|
}
|
|
|
|
dm3IdentSysDescriptionIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant description record."
|
|
::= { dm3IdentSysDescriptionEntry 1 }
|
|
|
|
dm3IdentSysDescriptionText OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 16 character text field describing the DC power plant device.
|
|
This field can be configured from the dm3ConfigSysDescriptionText OID."
|
|
::= { dm3IdentSysDescriptionEntry 2 }
|
|
|
|
dm3IdentSysModel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Model type of the DC power plant."
|
|
::= { dm3IdentSystem 3 }
|
|
|
|
dm3IdentSysCntrlRev OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Integer representation of the hardware revision of the Master Controller board."
|
|
::= { dm3IdentSystem 4 }
|
|
|
|
dm3IdentSysFWVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Integer representation of the power plant Master Controller firmware revision."
|
|
::= { dm3IdentSystem 5 }
|
|
|
|
-- the dm3ConfigSystem group
|
|
|
|
dm3ConfigSysDescriptionTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC description records."
|
|
::= { dm3ConfigSystem 1 }
|
|
|
|
dm3ConfigSysDescriptionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3ConfigSysDescriptionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing description records of the powerplant. The number of
|
|
entries is contained in the dm3ConfigSysDescriptionTableSize OID."
|
|
::= { dm3ConfigSystem 2 }
|
|
|
|
dm3ConfigSysDescriptionEntry OBJECT-TYPE
|
|
SYNTAX Dm3ConfigSysDescriptionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The powerplant description record to reference."
|
|
INDEX { dm3ConfigSysDescriptionIndex }
|
|
::= { dm3ConfigSysDescriptionTable 1 }
|
|
|
|
Dm3ConfigSysDescriptionEntry ::=
|
|
SEQUENCE {
|
|
dm3ConfigSysDescriptionIndex INTEGER,
|
|
dm3ConfigSysDescriptionText DisplayString
|
|
}
|
|
|
|
dm3ConfigSysDescriptionIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant description record."
|
|
|
|
::= { dm3ConfigSysDescriptionEntry 1 }
|
|
|
|
dm3ConfigSysDescriptionText OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"16 character text field describing the DC power plant device."
|
|
|
|
::= { dm3ConfigSysDescriptionEntry 2 }
|
|
|
|
dm3ConfigSysHighTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ambient high temperature threshold. Temperature sensor located on Master
|
|
Controller board.
|
|
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
|
|
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigSystem 3 }
|
|
|
|
dm3ConfigSysHighTempAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the System High Temperature Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
::= { dm3ConfigSystem 4 }
|
|
|
|
dm3ConfigSysLowTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ambient low temperature threshold. Temperature sensor located on Master
|
|
Controller board.
|
|
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
|
|
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigSystem 5 }
|
|
|
|
dm3ConfigSysLowTempAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the System Low Temperature Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
::= { dm3ConfigSystem 6 }
|
|
|
|
dm3ConfigSysHardwareTempAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the System Hardware Temperature Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
::= { dm3ConfigSystem 7 }
|
|
|
|
dm3ConfigSysRemoteAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
accessEnabled (1),
|
|
accessDisabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"
|
|
This OID is used to disable remote write access to the power plant.
|
|
Setting this OID to accessEnabled (1) will have no affect.
|
|
Setting this OID to accessDisabled (2) will disable the ability to
|
|
remotely configure the DC powerplant.
|
|
|
|
Once remote access is disabled, it can only be restored from the front
|
|
panel of the DC power plant."
|
|
::= { dm3ConfigSystem 8 }
|
|
|
|
|
|
-- the dm3ConfigLVD group
|
|
|
|
dm3ConfigLVDTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant LVDs controllable
|
|
by this IP address."
|
|
::= { dm3ConfigLVD 1 }
|
|
|
|
dm3ConfigLVDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3ConfigLVDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing settings of the LVDs. The number of
|
|
entries is contained in the dm3ConfigLVDTableSize OID."
|
|
::= { dm3ConfigLVD 2 }
|
|
|
|
dm3ConfigLVDEntry OBJECT-TYPE
|
|
SYNTAX Dm3ConfigLVDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The LVD to configure."
|
|
INDEX { dm3ConfigLVDIndex }
|
|
::= { dm3ConfigLVDTable 1 }
|
|
|
|
Dm3ConfigLVDEntry ::=
|
|
SEQUENCE {
|
|
dm3ConfigLVDIndex INTEGER,
|
|
dm3ConfigLVDName DisplayString,
|
|
dm3ConfigLVDEnable INTEGER,
|
|
dm3ConfigLVDTripThresh INTEGER,
|
|
dm3ConfigLVDResetThresh INTEGER,
|
|
dm3ConfigLVDOpenAlarm INTEGER,
|
|
dm3ConfigLVDHWAlarm INTEGER
|
|
}
|
|
|
|
dm3ConfigLVDIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant LVD."
|
|
::= { dm3ConfigLVDEntry 1 }
|
|
|
|
dm3ConfigLVDName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the LVD. The maximum value is 16 characters."
|
|
::= { dm3ConfigLVDEntry 2 }
|
|
|
|
dm3ConfigLVDEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabledYes (1),
|
|
enabledNo (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID is used to control and indicate if the LVD is on or off.
|
|
Setting this OID to enabledYes (1) will enable (turn on) the LVD.
|
|
Setting this OID to enabledNo (2) will disable (turn off) the LVD."
|
|
::= { dm3ConfigLVDEntry 3 }
|
|
|
|
dm3ConfigLVDTripThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LVD Trip threshold. If voltage exceeds threshold, the LVD will trip.
|
|
|
|
Values are represented in thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigLVDEntry 4 }
|
|
|
|
dm3ConfigLVDResetThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LVD Reset threshold. If voltage exceeds threshold, the LVD will reset.
|
|
|
|
Values are represented in thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigLVDEntry 5 }
|
|
|
|
dm3ConfigLVDOpenAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the LVD Open Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
::= { dm3ConfigLVDEntry 6 }
|
|
|
|
dm3ConfigLVDHWAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the LVD Hardware Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
::= { dm3ConfigLVDEntry 7 }
|
|
|
|
|
|
-- the dm3ConfigBattery group
|
|
|
|
dm3ConfigBattFloatVolt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Float Voltage. This setting controls the power plant voltage.
|
|
|
|
Values are represented in thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigBattery 1 }
|
|
|
|
dm3ConfigBattMaxRecharge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Maximum Recharge Rate. This setting controls the battery max
|
|
recharge rate. The value is based on C/20 for 240 AHr battery string.
|
|
|
|
Values are represented in thousandths of Amps (mA).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigBattery 2 }
|
|
|
|
dm3ConfigBattDischargeThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery discharge threshold. If battery output current exceeds threshold
|
|
a battery discharge alarm will occur.
|
|
|
|
Values are represented in thousandths of Amps (mA).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigBattery 3 }
|
|
|
|
dm3ConfigBattDischargeAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Battery Discharge Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigBattery 4 }
|
|
|
|
dm3ConfigBattHighVoltThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery high voltage threshold. If system battery voltage exceeds threshold
|
|
a battery high voltage alarm will occur.
|
|
|
|
Values are represented in thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigBattery 5 }
|
|
|
|
dm3ConfigBattHighVoltAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Battery High Voltage Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigBattery 6 }
|
|
|
|
dm3ConfigBattLowVoltThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery low voltage threshold. If system battery voltage is under threshold
|
|
a battery low voltage alarm will occur.
|
|
|
|
Values are represented in thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigBattery 7 }
|
|
|
|
dm3ConfigBattLowVoltAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Battery Low Voltage Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigBattery 8 }
|
|
|
|
dm3ConfigBattHighTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery high temperature threshold. If system battery temperature exceeds threshold
|
|
a battery high temperature alarm will occur.
|
|
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
|
|
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
|
|
::= { dm3ConfigBattery 9 }
|
|
|
|
dm3ConfigBattHighTempAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Battery High Temperature Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigBattery 10 }
|
|
|
|
dm3ConfigBattLowTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery low temperature threshold. If system battery temperature is under threshold
|
|
a battery low temperature alarm will occur.
|
|
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
|
|
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
|
|
::= { dm3ConfigBattery 11 }
|
|
|
|
dm3ConfigBattLowTempAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Battery Low Temperature Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigBattery 12 }
|
|
|
|
dm3ConfigBattAmpHour OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Amp-Hour Size. Units are thousandths of Amp hours (mAHr).
|
|
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigBattery 13 }
|
|
|
|
dm3ConfigCompMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tempcompOn (1),
|
|
tempcompOff (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID is used to configure and get the state of the battery
|
|
temperature compensation.
|
|
|
|
Setting this OID to tempcompOn (1) will enable/turn on the battery temperature compensation.
|
|
Setting this OID to tempcompOff (2) will disable/turn off the battery temperature compensation."
|
|
::= { dm3ConfigBattery 14 }
|
|
|
|
dm3ConfigCompTempCoeff OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compensation Temperature Coefficient. (uV/degC/cell).
|
|
|
|
Units are presented in microvolts.
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigBattery 15 }
|
|
|
|
dm3ConfigHighKneeTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"High Knee for temperature compensation: Compensation temperature coefficient
|
|
becomes 0mV/degC/cell.
|
|
|
|
Values are represented in thousandths of degrees Celsius.
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigBattery 16 }
|
|
|
|
dm3ConfigLowKneeTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Low Knee for temperature compensation: Compensation temperature coefficient
|
|
becomes 0mV/degC/cell.
|
|
|
|
Values are represented in thousandths of degrees Celsius.
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigBattery 17 }
|
|
|
|
dm3ConfigBattHwCurrentAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Battery Current Hardware Alarm (indicating current is outside realistic
|
|
limits, or a possible measurement fault;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigBattery 18 }
|
|
|
|
dm3ConfigBattHwTempAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Battery Temperature Hardware Alarm (indicating temperature is outside realistic
|
|
limits, or a possible measurement fault;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigBattery 19 }
|
|
|
|
|
|
-- the dm3ConfigRectThresh group
|
|
dm3ConfigRectHighVoltThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Rectifier high voltage threshold. If rectifier voltage exceeds threshold
|
|
a rectifier high voltage alarm will occur.
|
|
|
|
Values are represented in thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigRectThresh 1 }
|
|
|
|
|
|
dm3ConfigRectLowVoltThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Rectifier low voltage threshold. If rectifier voltage is under threshold
|
|
a rectifier low voltage alarm will occur.
|
|
|
|
Values are represented in thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigRectThresh 2 }
|
|
|
|
dm3ConfigRectFailSafe OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Rectifier Fail Safe point. This OID represents the value sent to rectifier controllers
|
|
to use in the event of communications loss with the Master Controller or Master Controller
|
|
board failure.
|
|
|
|
Values are represented in thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigRectThresh 3 }
|
|
|
|
dm3ConfigRectFailComm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Rectifier Communication Fail timeout. This OID represents the time interval in which there is no
|
|
communication between the rectifier and the master controller at which the rectifier will reset
|
|
all its values to default.
|
|
|
|
Values are represented in hundredths of Seconds.
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigRectThresh 4 }
|
|
|
|
-- the dm3ConfigRectAlarms group
|
|
|
|
dm3ConfigRectHighVoltAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Rectifier High Voltage Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigRectAlarms 1 }
|
|
|
|
dm3ConfigRectLowVoltAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Rectifier Low Voltage Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigRectAlarms 2 }
|
|
|
|
dm3ConfigRectConfigAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This alarm is activated when a new rectifier is detected;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigRectAlarms 3 }
|
|
|
|
dm3ConfigRect1ofNAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This setting indicates the action if ONE rectifier of a N+1 system has failed;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigRectAlarms 4 }
|
|
|
|
dm3ConfigRect2ofNAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This setting indicates the action if TWO OR MORE rectifiers of a N+1 system have failed;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigRectAlarms 5 }
|
|
|
|
dm3ConfigRectDiagAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Rectifier Controller Diagnostics Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID
|
|
to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system."
|
|
|
|
::= { dm3ConfigRectAlarms 6 }
|
|
|
|
dm3ConfigRectImbalanceAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Rectifier Imbalance Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigRectAlarms 7 }
|
|
|
|
dm3ConfigRectCurrLimitAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Rectifier Current Limit Alarm (indicating rectifier in the Current Limit state);
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID
|
|
to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system."
|
|
|
|
::= { dm3ConfigRectAlarms 8 }
|
|
|
|
dm3ConfigRectStandbyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Rectifier Standby Alarm (indicating output DC has been turned off);
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID
|
|
to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system."
|
|
|
|
::= { dm3ConfigRectAlarms 9 }
|
|
|
|
dm3ConfigRectFanFailAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Rectifier Fan Fail Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID
|
|
to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system."
|
|
|
|
::= { dm3ConfigRectAlarms 10 }
|
|
|
|
dm3ConfigRectFailAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Rectifier Fail Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID
|
|
to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system."
|
|
|
|
::= { dm3ConfigRectAlarms 11 }
|
|
|
|
dm3ConfigRectHwVoltAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Rectifier Hardware Voltage Alarm (indicating voltage outside realistic limits,
|
|
or a possible measurement fault);
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigRectAlarms 12 }
|
|
|
|
|
|
-- the dm3ConfigConvThresh group
|
|
|
|
dm3ConfigConvHighVoltThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Converter high voltage threshold. If converter voltage exceeds threshold
|
|
a converter high voltage alarm will occur.
|
|
|
|
Values are represented in thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
|
|
::= { dm3ConfigConvThresh 1 }
|
|
|
|
dm3ConfigConvLowVoltThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Converter low voltage threshold. If converter voltage exceeds threshold
|
|
a converter low voltage alarm will occur.
|
|
|
|
Values are represented in thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigConvThresh 2 }
|
|
|
|
dm3ConfigConvFailSafe OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Converter Fail Safe point. This OID represents the value sent to converter controllers
|
|
to use in the event of communications loss with the Master Controller or Master Controller
|
|
board failure.
|
|
|
|
Values are represented in thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigConvThresh 3 }
|
|
|
|
dm3ConfigConvSetPoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Converter Set point. This OID represents the initial set point used in the
|
|
voltage control loop.
|
|
|
|
Units are thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigConvThresh 4 }
|
|
|
|
dm3ConfigConvFailMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Converter Fail Maximum limit. This OID represents the value sent to the converter
|
|
controllers to define the maximum set point allowed.
|
|
|
|
Units are thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigConvThresh 5 }
|
|
|
|
dm3ConfigConvFailMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Converter Fail Minimum limit. This OID represents the value sent to the converter
|
|
controllers to define the minimum set point allowed.
|
|
|
|
Units are thousandths of Volts (mV).
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigConvThresh 6 }
|
|
|
|
dm3ConfigConvFailComm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Converter Communication Fail timeout. This OID represents the time interval in which there is no
|
|
communication between the converter and the master controller at which the converter will reset
|
|
all its values to default.
|
|
|
|
Values are represented in hundredths of Seconds.
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigConvThresh 7 }
|
|
|
|
-- the dm3ConfigConvAlarms group
|
|
dm3ConfigConvHighVoltAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter High Voltage Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigConvAlarms 1 }
|
|
|
|
dm3ConfigConvLowVoltAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter Low Voltage Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigConvAlarms 2 }
|
|
|
|
dm3ConfigConvConfigAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter Configuration Alarm (indicating a new converter has been detected);
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigConvAlarms 3 }
|
|
|
|
dm3ConfigConv1ofNAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter 1ofN Alarm (indicating action if ONE converter of a N+1 system has failed);
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigConvAlarms 4 }
|
|
|
|
dm3ConfigConv2ofNAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter 2ofN Alarm (indicating action if TWO OR MORE converters of a N+1 system has failed);
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigConvAlarms 5 }
|
|
|
|
dm3ConfigConvDiagAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter Diagnostics Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
|
|
to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
|
|
|
|
::= { dm3ConfigConvAlarms 6 }
|
|
|
|
dm3ConfigConvImbalanceAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter Imbalance Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
|
|
to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
|
|
|
|
::= { dm3ConfigConvAlarms 7 }
|
|
|
|
dm3ConfigConvCurrLimitAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter Current Limit Alarm (indicating the converter is in the Current Limit state);
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
|
|
to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
|
|
|
|
::= { dm3ConfigConvAlarms 8 }
|
|
|
|
dm3ConfigConvStandbyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter Standby Alarm (indicating the converter is in the Standby state);
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
|
|
to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
|
|
|
|
::= { dm3ConfigConvAlarms 9 }
|
|
|
|
dm3ConfigConvFanFailAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter Fan Fail Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
|
|
to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
|
|
|
|
::= { dm3ConfigConvAlarms 10 }
|
|
|
|
dm3ConfigConvFailAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter Fail Alarm;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
|
|
to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
|
|
|
|
::= { dm3ConfigConvAlarms 11 }
|
|
|
|
dm3ConfigConvHwVoltAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9),
|
|
alarmNofN (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the Converter Voltage Alarm (indicating voltage outside realistic limits, or a
|
|
possible measurement fault);
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
|
|
to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
|
|
dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
|
|
|
|
::= { dm3ConfigConvAlarms 12 }
|
|
|
|
|
|
-- the dm3ConfigOutputRelays group
|
|
|
|
dm3ConfigOutRlyTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant Output Relays controllable
|
|
by this IP address."
|
|
::= { dm3ConfigOutputRelays 1 }
|
|
|
|
dm3ConfigOutRlyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3ConfigOutRlyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing settings of the Output Relays. The number of
|
|
entries is contained in the dm3ConfigOutRlyTableSize OID."
|
|
::= { dm3ConfigOutputRelays 2 }
|
|
|
|
dm3ConfigOutRlyEntry OBJECT-TYPE
|
|
SYNTAX Dm3ConfigOutRlyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output relay to configure."
|
|
INDEX { dm3ConfigOutRlyIndex }
|
|
::= { dm3ConfigOutRlyTable 1 }
|
|
|
|
Dm3ConfigOutRlyEntry ::=
|
|
SEQUENCE {
|
|
dm3ConfigOutRlyIndex INTEGER,
|
|
dm3ConfigOutRlyName DisplayString,
|
|
dm3ConfigOutRlyDelay INTEGER,
|
|
dm3ConfigOutRlyAlarm INTEGER
|
|
}
|
|
|
|
dm3ConfigOutRlyIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant output relay."
|
|
::= { dm3ConfigOutRlyEntry 1 }
|
|
|
|
dm3ConfigOutRlyName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the output relay. The maximum value is 16 characters."
|
|
::= { dm3ConfigOutRlyEntry 2 }
|
|
|
|
dm3ConfigOutRlyDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output Relay Delay. This OID represents the time delay from the initiation of an
|
|
output relay action to when the output relay action does occur. If the alarm condition
|
|
disappears before the end of the delay, no action will occur. Delay for Major
|
|
and Minor alarms is not configurable and is always set to 0.
|
|
|
|
Values are represented in hundredths of seconds.
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigOutRlyEntry 3 }
|
|
|
|
dm3ConfigOutRlyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output Relay Alarm. This setting indicates what action to perform in the event of
|
|
an output relay alarm condition;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition.
|
|
|
|
Relay Alarm for Major and Minor alarms is not configurable and is always set to
|
|
alarmMajor and alarmMinor respectively."
|
|
|
|
::= { dm3ConfigOutRlyEntry 4 }
|
|
|
|
|
|
-- the dm3ConfigInputRelays group
|
|
|
|
dm3ConfigInRlyTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant Input Relays controllable
|
|
by this IP address."
|
|
::= { dm3ConfigInputRelays 1 }
|
|
|
|
dm3ConfigInRlyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3ConfigInRlyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing settings of the Input Relays. The number of
|
|
entries is contained in the dm3ConfigInRlyTableSize OID."
|
|
::= { dm3ConfigInputRelays 2 }
|
|
|
|
dm3ConfigInRlyEntry OBJECT-TYPE
|
|
SYNTAX Dm3ConfigInRlyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input relay to configure."
|
|
INDEX { dm3ConfigInRlyIndex }
|
|
::= { dm3ConfigInRlyTable 1 }
|
|
|
|
Dm3ConfigInRlyEntry ::=
|
|
SEQUENCE {
|
|
dm3ConfigInRlyIndex INTEGER,
|
|
dm3ConfigInRlyName DisplayString,
|
|
dm3ConfigInRlyDelay INTEGER,
|
|
dm3ConfigInRlyAlarm INTEGER
|
|
}
|
|
|
|
dm3ConfigInRlyIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant input relay."
|
|
::= { dm3ConfigInRlyEntry 1 }
|
|
|
|
dm3ConfigInRlyName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the input relay. The maximum value is 16 characters."
|
|
|
|
::= { dm3ConfigInRlyEntry 2 }
|
|
|
|
dm3ConfigInRlyDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input Relay Delay. This OID represents the time delay from the initiation of an
|
|
input relay action to when the input relay action does occur. If the alarm condition
|
|
disappears before the end of the delay, no action will occur.
|
|
|
|
Values are represented in hundredths of seconds.
|
|
|
|
Attempts to set the value above or below the acceptable range of the powerplant
|
|
will cause the value to be set at the high or low point of the range respectively."
|
|
::= { dm3ConfigInRlyEntry 3 }
|
|
|
|
dm3ConfigInRlyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input Relay Alarm. This setting indicates what action to perform in the event of
|
|
an input relay alarm condition;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigInRlyEntry 4 }
|
|
|
|
-- the dm3ConfigBreakers group
|
|
|
|
dm3ConfigBreakersTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant circuit breakers controllable
|
|
by this IP address."
|
|
::= { dm3ConfigBreakers 1 }
|
|
|
|
dm3ConfigBreakersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3ConfigBreakersEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing settings of the circuit breakers. The number of
|
|
entries is contained in the dm3ConfigBreakersTableSize OID."
|
|
::= { dm3ConfigBreakers 2 }
|
|
|
|
dm3ConfigBreakersEntry OBJECT-TYPE
|
|
SYNTAX Dm3ConfigBreakersEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The circuit breaker to configure."
|
|
INDEX { dm3ConfigBreakersIndex }
|
|
::= { dm3ConfigBreakersTable 1 }
|
|
|
|
Dm3ConfigBreakersEntry ::=
|
|
SEQUENCE {
|
|
dm3ConfigBreakersIndex INTEGER,
|
|
dm3ConfigBreakersName DisplayString,
|
|
dm3ConfigBreakersAlarm INTEGER
|
|
}
|
|
|
|
dm3ConfigBreakersIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant circuit breaker."
|
|
::= { dm3ConfigBreakersEntry 1 }
|
|
|
|
dm3ConfigBreakersName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the circuit breaker. The maximum value is 16 characters."
|
|
::= { dm3ConfigBreakersEntry 2 }
|
|
|
|
dm3ConfigBreakersAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Circuit Breaker Alarm. This setting indicates what action to perform in the event of
|
|
a circuit breaker alarm condition;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigBreakersEntry 3 }
|
|
|
|
-- the dm3ConfigFuses group
|
|
|
|
dm3ConfigFusesTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant Fuses controllable
|
|
by this IP address."
|
|
::= { dm3ConfigFuses 1 }
|
|
|
|
dm3ConfigFusesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3ConfigFusesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing settings of the Fuses. The number of
|
|
entries is contained in the dm3ConfigFusesTableSize OID."
|
|
::= { dm3ConfigFuses 2 }
|
|
|
|
dm3ConfigFusesEntry OBJECT-TYPE
|
|
SYNTAX Dm3ConfigFusesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fuse to configure."
|
|
INDEX { dm3ConfigFusesIndex }
|
|
::= { dm3ConfigFusesTable 1 }
|
|
|
|
Dm3ConfigFusesEntry ::=
|
|
SEQUENCE {
|
|
dm3ConfigFusesIndex INTEGER,
|
|
dm3ConfigFusesName DisplayString,
|
|
dm3ConfigFusesAlarm INTEGER
|
|
}
|
|
|
|
dm3ConfigFusesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant fuse."
|
|
::= { dm3ConfigFusesEntry 1 }
|
|
|
|
dm3ConfigFusesName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the fuse. The maximum value is 16 characters."
|
|
::= { dm3ConfigFusesEntry 2 }
|
|
|
|
dm3ConfigFusesAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmIgnore (1),
|
|
alarmRelay1 (2),
|
|
alarmRelay2 (3),
|
|
alarmRelay3 (4),
|
|
alarmRelay4 (5),
|
|
alarmRelay5 (6),
|
|
alarmRelay6 (7),
|
|
alarmMinor (8),
|
|
alarmMajor (9)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuses Alarm. This setting indicates what action to perform in the event of
|
|
a Fuse alarm condition;
|
|
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
|
|
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
|
|
alarm condition.
|
|
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
|
|
alarm condition."
|
|
|
|
::= { dm3ConfigFusesEntry 3 }
|
|
|
|
-- the dm3StatusSystem group
|
|
|
|
dm3StatusSystemTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System temperature based on sensor on Master Controller PCB.
|
|
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit)."
|
|
|
|
::= { dm3StatusSystem 1 }
|
|
|
|
dm3StatusSystemStart OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time stamp at DC powerplant initialization.
|
|
The time is represented as MMM,DD,YYYY,HH:MM:SS."
|
|
::= { dm3StatusSystem 2 }
|
|
|
|
dm3StatusSysRemoteAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
accessEnabled (1),
|
|
accessDisabled (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote Access indicator
|
|
This setting indicates if configuration (write) access to the powerplant is enabled or
|
|
disabled at the powerplant level.
|
|
This value will be accessEnabled (1) if remote configuration is enabled, and
|
|
accessDisabled (2) if remote configuration is disabled."
|
|
::= { dm3StatusSystem 3 }
|
|
|
|
dm3StatusSysSecurityLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable shows the current active security access level of controller. This
|
|
can only be changed directly from the front panel."
|
|
::= { dm3StatusSystem 4 }
|
|
|
|
dm3StatusSysTempSanity OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
saneYES (1),
|
|
saneNO (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System temperature sanity indicator. Indicates if the system temperature is
|
|
reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1)
|
|
indicates temperature is reasonable, a value of saneNo (2) indicates it is not."
|
|
::= { dm3StatusSystem 5 }
|
|
|
|
dm3StatusSysAlarmState OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
alarmMinor (1),
|
|
alarmMajor (2),
|
|
alarmBoth (3),
|
|
alarmNone (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Alarm State. Reflects the alarm status of the overall DC system.
|
|
If a minor alarm is present, the value will be alarmMinor(1).
|
|
If a major alarm is present, the value will be alarmMajor(2).
|
|
If both minor and a major alarm is present, the value will be alarmBoth(3).
|
|
If no alarm is present, the value will be alarmNone(4)."
|
|
::= { dm3StatusSystem 6 }
|
|
|
|
dm3StatusSysTempUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
celsius(1),
|
|
fahrenheit(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature scale used to display the temperature
|
|
in the DC system, Celsius(1) or Fahrenheit(2).
|
|
This setting is based on the system preferences
|
|
configuration in the agent."
|
|
::= { dm3StatusSystem 7 }
|
|
|
|
|
|
-- the dm3StatusAlarms group
|
|
|
|
dm3StatusAlarmsTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant alarms viewable
|
|
by this IP address."
|
|
::= { dm3StatusAlarms 1 }
|
|
|
|
dm3StatusAlarmsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3StatusAlarmsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing system alarms. The number of
|
|
entries is contained in the dm3StatusAlarmsTableSize OID."
|
|
::= { dm3StatusAlarms 2 }
|
|
|
|
dm3StatusAlarmsEntry OBJECT-TYPE
|
|
SYNTAX Dm3StatusAlarmsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm to display."
|
|
INDEX { dm3StatusAlarmsIndex }
|
|
::= { dm3StatusAlarmsTable 1 }
|
|
|
|
Dm3StatusAlarmsEntry ::=
|
|
SEQUENCE {
|
|
dm3StatusAlarmsIndex INTEGER,
|
|
dm3StatusAlarmsText DisplayString
|
|
}
|
|
|
|
dm3StatusAlarmsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the system alarm."
|
|
::= { dm3StatusAlarmsEntry 1 }
|
|
|
|
dm3StatusAlarmsText OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The 16 character text describing the active alarm condition."
|
|
::= { dm3StatusAlarmsEntry 2 }
|
|
|
|
-- the dm3StatusBattery group
|
|
|
|
dm3StatusBattCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Current: This OID shows the battery current in thousandths of Amps (mA)."
|
|
::= { dm3StatusBattery 1 }
|
|
|
|
dm3StatusBattTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Temperature:
|
|
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit)."
|
|
|
|
::= { dm3StatusBattery 2 }
|
|
|
|
dm3StatusBattCurrentSanity OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
saneYES (1),
|
|
saneNO (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery current sanity indicator. Indicates if the battery current is
|
|
reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1)
|
|
indicates current is reasonable, a value of saneNo (2) indicates it is not."
|
|
::= { dm3StatusBattery 3 }
|
|
|
|
dm3StatusBattTempSanity OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
saneYES (1),
|
|
saneNO (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery temperature sanity indicator. Indicates if the battery temperature is
|
|
reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1)
|
|
indicates temperature is reasonable, a value of saneNo (2) indicates it is not."
|
|
::= { dm3StatusBattery 4 }
|
|
|
|
-- the dm3StatusOEM group
|
|
|
|
dm3StatusOEMrectOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier offset value in thousandths of Volts (mV)."
|
|
::= { dm3StatusOEM 1 }
|
|
|
|
dm3StatusOEMrectGain OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier gain value in thousandths of Volts (mV/V)."
|
|
::= { dm3StatusOEM 2 }
|
|
|
|
dm3StatusOEMconvOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the converter offset value in thousandths of Volts (mV)."
|
|
::= { dm3StatusOEM 3 }
|
|
|
|
dm3StatusOEMconvGain OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the converter gain value in thousandths of Volts (mV/V)."
|
|
::= { dm3StatusOEM 4 }
|
|
|
|
dm3StatusOEMshuntOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the shunt offset value in thousandths of Amps (mA)."
|
|
::= { dm3StatusOEM 5 }
|
|
|
|
dm3StatusOEMshuntGain OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the shunt gain value in thousandths of Amps (mA/A)."
|
|
::= { dm3StatusOEM 6 }
|
|
|
|
-- the dm3StatusLVD group
|
|
|
|
dm3StatusLVDTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant LVDs viewable
|
|
by this IP address."
|
|
::= { dm3StatusLVD 1 }
|
|
|
|
dm3StatusLVDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3StatusLVDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing settings of the LVDs. The number of
|
|
entries is contained in the dm3StatusLVDTableSize OID."
|
|
::= { dm3StatusLVD 2 }
|
|
|
|
dm3StatusLVDEntry OBJECT-TYPE
|
|
SYNTAX Dm3StatusLVDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The LVD to gather status from."
|
|
INDEX { dm3StatusLVDIndex }
|
|
::= { dm3StatusLVDTable 1 }
|
|
|
|
Dm3StatusLVDEntry ::=
|
|
SEQUENCE {
|
|
dm3StatusLVDIndex INTEGER,
|
|
dm3StatusLVDName DisplayString,
|
|
dm3StatusLVDState INTEGER,
|
|
dm3StatusLVDHwFault INTEGER
|
|
}
|
|
|
|
dm3StatusLVDIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant LVD."
|
|
::= { dm3StatusLVDEntry 1 }
|
|
|
|
dm3StatusLVDName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the LVD. The maximum size is
|
|
16 characters. The name is set by using the
|
|
dm3ConfigLVDName OID.
|
|
This OID is provided for informational purposes only."
|
|
::= { dm3StatusLVDEntry 2 }
|
|
|
|
dm3StatusLVDState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusClosed (1),
|
|
statusOpened (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusClosed (1) if the LVD is closed.
|
|
statusOpened (2) will be returned if the LVD is opened."
|
|
::= { dm3StatusLVDEntry 3 }
|
|
|
|
dm3StatusLVDHwFault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusFault (1),
|
|
statusNofault (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusFault (1) if the LVD is faulted.
|
|
statusNofault (2) will be returned if the LVD is not faulted."
|
|
::= { dm3StatusLVDEntry 4 }
|
|
|
|
-- the dm3StatusRectifier group
|
|
|
|
dm3StatusRectTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant rectifiers viewable
|
|
by this IP address."
|
|
::= { dm3StatusRectifier 1 }
|
|
|
|
dm3StatusRectTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3StatusRectEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing settings of the rectifiers. The number of
|
|
entries is contained in the dm3StatusRectTableSize OID."
|
|
::= { dm3StatusRectifier 2 }
|
|
|
|
dm3StatusRectEntry OBJECT-TYPE
|
|
SYNTAX Dm3StatusRectEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rectifier to gather status from."
|
|
INDEX { dm3StatusRectIndex }
|
|
::= { dm3StatusRectTable 1 }
|
|
|
|
Dm3StatusRectEntry ::=
|
|
SEQUENCE {
|
|
dm3StatusRectIndex INTEGER,
|
|
dm3StatusRectID INTEGER,
|
|
dm3StatusRectDesc DisplayString,
|
|
dm3StatusRectCurrent INTEGER,
|
|
dm3StatusRectCurrentLimit INTEGER,
|
|
dm3StatusRectStandby INTEGER,
|
|
dm3StatusRectFanFail INTEGER,
|
|
dm3StatusRectFail INTEGER,
|
|
dm3StatusRectDevType INTEGER,
|
|
dm3StatusRectPhyAddr INTEGER,
|
|
dm3StatusRectCfg INTEGER,
|
|
dm3StatusRectPcbRev INTEGER,
|
|
dm3StatusRectFwVer INTEGER,
|
|
dm3StatusRectPresent INTEGER,
|
|
dm3StatusRectDiagPass INTEGER,
|
|
dm3StatusRectState INTEGER
|
|
}
|
|
|
|
dm3StatusRectIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant rectifier."
|
|
::= { dm3StatusRectEntry 1 }
|
|
|
|
dm3StatusRectID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier ID. This enumerates the number of the rectifier within
|
|
a group of rectifiers."
|
|
::= { dm3StatusRectEntry 2 }
|
|
|
|
dm3StatusRectDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the 16-character rectifier description."
|
|
::= { dm3StatusRectEntry 3 }
|
|
|
|
dm3StatusRectCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier current in thousandths of Amps (mA)."
|
|
::= { dm3StatusRectEntry 4 }
|
|
|
|
dm3StatusRectCurrentLimit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the rectifier is in the Current Limit state.
|
|
statusFalse (2) will be returned if the rectifier is not in the Current Limit state."
|
|
::= { dm3StatusRectEntry 5 }
|
|
|
|
dm3StatusRectStandby OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the rectifier is in the Standby state.
|
|
statusFalse (2) will be returned if the rectifier is not in the Standby state."
|
|
::= { dm3StatusRectEntry 6 }
|
|
|
|
dm3StatusRectFanFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the rectifier Fan has failed.
|
|
statusFalse (2) will be returned if the rectifier Fan has not failed."
|
|
::= { dm3StatusRectEntry 7 }
|
|
|
|
dm3StatusRectFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the rectifier has failed.
|
|
statusFalse (2) will be returned if the rectifier has not failed."
|
|
::= { dm3StatusRectEntry 8 }
|
|
|
|
dm3StatusRectDevType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier device type."
|
|
::= { dm3StatusRectEntry 9 }
|
|
|
|
dm3StatusRectPhyAddr OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier physical address (the address on the bus)."
|
|
::= { dm3StatusRectEntry 10 }
|
|
|
|
dm3StatusRectCfg OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the rectifier is present after
|
|
power-up or set-configuration.
|
|
statusFalse (2) will be returned if the rectifier is not configured."
|
|
::= { dm3StatusRectEntry 11 }
|
|
|
|
dm3StatusRectPcbRev OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier device PCB serial number."
|
|
::= { dm3StatusRectEntry 12 }
|
|
|
|
dm3StatusRectFwVer OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier device firmware revision."
|
|
::= { dm3StatusRectEntry 13 }
|
|
|
|
dm3StatusRectPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the rectifier is present.
|
|
statusFalse (2) will be returned if the rectifier is not present."
|
|
::= { dm3StatusRectEntry 14 }
|
|
|
|
dm3StatusRectDiagPass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the rectifier diagnostics have passed.
|
|
statusFalse (2) will be returned if the rectifier diagnostics have not passed."
|
|
::= { dm3StatusRectEntry 15 }
|
|
|
|
dm3StatusRectState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier device state as defined by the device status register."
|
|
::= { dm3StatusRectEntry 16 }
|
|
|
|
dm3StatusSysRectVoltSanity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
saneYES (1),
|
|
saneNO (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Rectifier voltage sanity indicator. Indicates if the rectifier voltage is
|
|
reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1)
|
|
indicates voltage is reasonable, a value of saneNo (2) indicates it is not."
|
|
::= { dm3StatusRectifier 3 }
|
|
|
|
dm3StatusSysRectAvailable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the rectifier is available.
|
|
statusFalse (2) will be returned if the rectifier is not available."
|
|
::= { dm3StatusRectifier 4 }
|
|
|
|
dm3StatusSysRectType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the type of rectifier the system has. There can only be a single type of
|
|
rectifier in the power plant"
|
|
::= { dm3StatusRectifier 5 }
|
|
|
|
dm3StatusSysRectVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the system level rectifier voltage in thousandths of Volts (mV)."
|
|
::= { dm3StatusRectifier 6 }
|
|
|
|
dm3StatusSysRectCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the system level rectifier current in thousandths of Amps (mA)."
|
|
::= { dm3StatusRectifier 7 }
|
|
|
|
|
|
-- the dm3StatusConverter group
|
|
|
|
dm3StatusConvTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant converters viewable
|
|
by this IP address."
|
|
::= { dm3StatusConverter 1 }
|
|
|
|
dm3StatusConvTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3StatusConvEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for viewing status of the converters. The number of
|
|
entries is contained in the dm3StatusConvTableSize OID."
|
|
::= { dm3StatusConverter 2 }
|
|
|
|
dm3StatusConvEntry OBJECT-TYPE
|
|
SYNTAX Dm3StatusConvEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The converter to gather status from."
|
|
INDEX { dm3StatusConvIndex }
|
|
::= { dm3StatusConvTable 1 }
|
|
|
|
Dm3StatusConvEntry ::=
|
|
SEQUENCE {
|
|
dm3StatusConvIndex INTEGER,
|
|
dm3StatusConvID INTEGER,
|
|
dm3StatusConvDesc DisplayString,
|
|
dm3StatusConvCurrent INTEGER,
|
|
dm3StatusConvCurrentLimit INTEGER,
|
|
dm3StatusConvStandby INTEGER,
|
|
dm3StatusConvFanFail INTEGER,
|
|
dm3StatusConvFail INTEGER,
|
|
dm3StatusConvDevType INTEGER,
|
|
dm3StatusConvPhyAddr INTEGER,
|
|
dm3StatusConvCfg INTEGER,
|
|
dm3StatusConvPcbRev INTEGER,
|
|
dm3StatusConvFwVer INTEGER,
|
|
dm3StatusConvPresent INTEGER,
|
|
dm3StatusConvDiagPass INTEGER,
|
|
dm3StatusConvState INTEGER
|
|
}
|
|
|
|
dm3StatusConvIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant converter."
|
|
::= { dm3StatusConvEntry 1 }
|
|
|
|
dm3StatusConvID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the converter ID. This enumerates the number of the converter within
|
|
a group of converters."
|
|
::= { dm3StatusConvEntry 2 }
|
|
|
|
dm3StatusConvDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the 16 character converter description."
|
|
::= { dm3StatusConvEntry 3 }
|
|
|
|
dm3StatusConvCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the converter current in thousandths of Amps (mA)."
|
|
::= { dm3StatusConvEntry 4 }
|
|
|
|
dm3StatusConvCurrentLimit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the converter is in the Current Limit state.
|
|
statusFalse (2) will be returned if the converter is not in the Current Limit state."
|
|
::= { dm3StatusConvEntry 5 }
|
|
|
|
dm3StatusConvStandby OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the converter is in the Standby state.
|
|
statusFalse (2) will be returned if the converter is not in the Standby state."
|
|
::= { dm3StatusConvEntry 6 }
|
|
|
|
dm3StatusConvFanFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the converter Fan has failed.
|
|
statusFalse (2) will be returned if the converter Fan has not failed."
|
|
::= { dm3StatusConvEntry 7 }
|
|
|
|
dm3StatusConvFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the converter has failed.
|
|
statusFalse (2) will be returned if the converter has not failed."
|
|
::= { dm3StatusConvEntry 8 }
|
|
|
|
dm3StatusConvDevType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the converter device type."
|
|
::= { dm3StatusConvEntry 9 }
|
|
|
|
dm3StatusConvPhyAddr OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the converter physical address (the address on the bus)."
|
|
::= { dm3StatusConvEntry 10 }
|
|
|
|
dm3StatusConvCfg OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the converter is present after
|
|
power-up or set-configuration.
|
|
statusFalse (2) will be returned if the converter is not configured."
|
|
::= { dm3StatusConvEntry 11 }
|
|
|
|
dm3StatusConvPcbRev OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the converter device PCB serial number."
|
|
::= { dm3StatusConvEntry 12 }
|
|
|
|
dm3StatusConvFwVer OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the converter device firmware version."
|
|
::= { dm3StatusConvEntry 13 }
|
|
|
|
dm3StatusConvPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the converter is present.
|
|
statusFalse (2) will be returned if the converter is not present."
|
|
::= { dm3StatusConvEntry 14 }
|
|
|
|
dm3StatusConvDiagPass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the converter diagnostics have passed.
|
|
statusFalse (2) will be returned if the converter diagnostics have not passed."
|
|
::= { dm3StatusConvEntry 15 }
|
|
|
|
dm3StatusConvState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the converter state as defined by the device status register."
|
|
::= { dm3StatusConvEntry 16 }
|
|
|
|
dm3StatusSysConvVoltSanity OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
saneYES (1),
|
|
saneNO (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Converter voltage sanity indicator. Indicates if the converter voltage is
|
|
reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1)
|
|
indicates voltage is reasonable, a value of saneNo (2) indicates it is not."
|
|
::= { dm3StatusConverter 3 }
|
|
|
|
dm3StatusSysConvAvailable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the converter is available.
|
|
statusFalse (2) will be returned if the converter is not available."
|
|
::= { dm3StatusConverter 4 }
|
|
|
|
dm3StatusSysConvType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the converter type."
|
|
::= { dm3StatusConverter 5 }
|
|
|
|
dm3StatusSysConvVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the system level converter voltage in thousandths of volts (mV)."
|
|
::= { dm3StatusConverter 6 }
|
|
|
|
dm3StatusSysConvCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the system level converter current in thousandths of Amps (mA)."
|
|
::= { dm3StatusConverter 7 }
|
|
|
|
-- the dm3StatusOutputRelays group
|
|
|
|
dm3StatusOutRlyTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant output relays viewable
|
|
by this IP address."
|
|
::= { dm3StatusOutputRelays 1 }
|
|
|
|
dm3StatusOutRlyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3StatusOutRlyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for viewing status of the output relays. The number of
|
|
entries is contained in the dm3StatusOutRlyTableSize OID."
|
|
::= { dm3StatusOutputRelays 2 }
|
|
|
|
dm3StatusOutRlyEntry OBJECT-TYPE
|
|
SYNTAX Dm3StatusOutRlyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output relay to gather status from."
|
|
INDEX { dm3StatusOutRlyIndex }
|
|
::= { dm3StatusOutRlyTable 1 }
|
|
|
|
Dm3StatusOutRlyEntry ::=
|
|
SEQUENCE {
|
|
dm3StatusOutRlyIndex INTEGER,
|
|
dm3StatusOutRlyName DisplayString,
|
|
dm3StatusOutRlyStatus INTEGER
|
|
}
|
|
|
|
dm3StatusOutRlyIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant output relay."
|
|
::= { dm3StatusOutRlyEntry 1 }
|
|
|
|
dm3StatusOutRlyName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the output relay. The maximum size is
|
|
16 characters. The name is set by using the
|
|
dm3ConfigOutRlyName OID.
|
|
This OID is provided for informational purposes only."
|
|
::= { dm3StatusOutRlyEntry 2 }
|
|
|
|
dm3StatusOutRlyStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusOn (1),
|
|
statusOff (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusOn (1) if the output relay is enabled/on.
|
|
statusOff (2) will be returned if the output relay is disabled/off."
|
|
::= { dm3StatusOutRlyEntry 3 }
|
|
|
|
|
|
-- the dm3StatusInputRelays group
|
|
|
|
dm3StatusInRlyTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant input relays viewable
|
|
by this IP address."
|
|
::= { dm3StatusInputRelays 1 }
|
|
|
|
dm3StatusInRlyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3StatusInRlyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for viewing status of the input relays. The number of
|
|
entries is contained in the dm3StatusInRlyTableSize OID."
|
|
::= { dm3StatusInputRelays 2 }
|
|
|
|
|
|
dm3StatusInRlyEntry OBJECT-TYPE
|
|
SYNTAX Dm3StatusInRlyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input relays to gather status from."
|
|
INDEX { dm3StatusInRlyIndex }
|
|
::= { dm3StatusInRlyTable 1 }
|
|
|
|
Dm3StatusInRlyEntry ::=
|
|
SEQUENCE {
|
|
dm3StatusInRlyIndex INTEGER,
|
|
dm3StatusInRlyName DisplayString,
|
|
dm3StatusInRlyStatus INTEGER
|
|
}
|
|
|
|
dm3StatusInRlyIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant input relay."
|
|
::= { dm3StatusInRlyEntry 1 }
|
|
|
|
dm3StatusInRlyName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the input relay. The maximum size is
|
|
16 characters. The name is set by using the
|
|
dm3ConfigInRlyName OID.
|
|
This OID is provided for informational purposes only."
|
|
::= { dm3StatusInRlyEntry 2 }
|
|
|
|
dm3StatusInRlyStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusOn (1),
|
|
statusOff (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusOn (1) if the input relay is enabled/on.
|
|
statusOff (2) will be returned if the input relay is disabled/off."
|
|
::= { dm3StatusInRlyEntry 3 }
|
|
|
|
-- the dm3StatusBreakers group
|
|
|
|
dm3StatusBreakersTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant circuit breakers viewable
|
|
by this IP address."
|
|
::= { dm3StatusBreakers 1 }
|
|
|
|
dm3StatusBreakersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3StatusBreakersEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for viewing status of the circuit breakers. The number of
|
|
entries is contained in the dm3StatusBreakersTableSize OID."
|
|
::= { dm3StatusBreakers 2 }
|
|
|
|
dm3StatusBreakersEntry OBJECT-TYPE
|
|
SYNTAX Dm3StatusBreakersEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The circuit breaker to gather status from."
|
|
INDEX { dm3StatusBreakersIndex }
|
|
::= { dm3StatusBreakersTable 1 }
|
|
|
|
Dm3StatusBreakersEntry ::=
|
|
SEQUENCE {
|
|
dm3StatusBreakersIndex INTEGER,
|
|
dm3StatusBreakersName DisplayString,
|
|
dm3StatusBreakersStatus INTEGER
|
|
}
|
|
|
|
dm3StatusBreakersIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant circuit breaker."
|
|
::= { dm3StatusBreakersEntry 1 }
|
|
|
|
dm3StatusBreakersName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the circuit breaker. The maximum size is
|
|
16 characters. The name is set by using the
|
|
dm3ConfigBreakersName OID.
|
|
This OID is provided for informational purposes only."
|
|
::= { dm3StatusBreakersEntry 2 }
|
|
|
|
dm3StatusBreakersStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusClosed (1),
|
|
statusOpen (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusClosed (1) if the circuit breaker is closed.
|
|
statusOpen (2) will be returned if the circuit breaker is open."
|
|
::= { dm3StatusBreakersEntry 3 }
|
|
|
|
-- the dm3StatusFuses group
|
|
|
|
dm3StatusFusesTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant fuses controllable
|
|
by this IP address."
|
|
::= { dm3StatusFuses 1 }
|
|
|
|
dm3StatusFusesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dm3StatusFusesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for viewing status of the fuses. The number of
|
|
entries is contained in the dm3StatusFusesTableSize OID."
|
|
::= { dm3StatusFuses 2 }
|
|
|
|
dm3StatusFusesEntry OBJECT-TYPE
|
|
SYNTAX Dm3StatusFusesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fuse to gather status from."
|
|
INDEX { dm3StatusFusesIndex }
|
|
::= { dm3StatusFusesTable 1 }
|
|
|
|
Dm3StatusFusesEntry ::=
|
|
SEQUENCE {
|
|
dm3StatusFusesIndex INTEGER,
|
|
dm3StatusFusesName DisplayString,
|
|
dm3StatusFusesStatus INTEGER
|
|
}
|
|
|
|
dm3StatusFusesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant fuse."
|
|
::= { dm3StatusFusesEntry 1 }
|
|
|
|
dm3StatusFusesName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the fuse. The maximum size is
|
|
16 characters. The name is set by using the
|
|
dm3ConfigFuseName OID.
|
|
This OID is provided for informational purposes only."
|
|
::= { dm3StatusFusesEntry 2 }
|
|
|
|
dm3StatusFusesStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusClosed (1),
|
|
statusOpen (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusClosed (1) if the fuse is closed.
|
|
statusOpen (2) will be returned if the fuse is open."
|
|
::= { dm3StatusFusesEntry 3 }
|
|
|
|
-- the atsIdent group
|
|
|
|
atsIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Automatic Transfer Switch.
|
|
This value is set at the factory."
|
|
::= { atsIdent 1 }
|
|
|
|
atsIdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string identifying the Automatic Transfer Switch
|
|
firmware revision."
|
|
::= { atsIdent 2 }
|
|
|
|
atsIdentFirmwareDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of release for this Automatic Transfer Switch
|
|
firmware revision. "
|
|
::= { atsIdent 3 }
|
|
|
|
atsIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the Automatic Transfer Switch was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory. "
|
|
::= { atsIdent 4 }
|
|
|
|
atsIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string identifying the model number of the Automatic Transfer Switch.
|
|
This value is set at the factory."
|
|
::= { atsIdent 5 }
|
|
|
|
atsIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string identifying the serial number of
|
|
the Automatic Transfer Switch. This value is set at the factory."
|
|
::= { atsIdent 6 }
|
|
|
|
atsIdentNominalLineVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RMS Utility Voltage measured in Volts."
|
|
::= { atsIdent 7 }
|
|
|
|
atsIdentNominalLineFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Utility Power Frequency measured in Hertz."
|
|
::= { atsIdent 8 }
|
|
|
|
atsIdentDeviceRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives the device rating in Amps"
|
|
::= { atsIdent 9 }
|
|
|
|
|
|
-- the atsCalibration group
|
|
|
|
-- Input Voltage Calibration Factor table
|
|
|
|
atsCalibrationNumInputs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of inputs to this device."
|
|
::= { atsCalibrationInput 1 }
|
|
|
|
atsCalibrationNumInputPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of phases per input for this device."
|
|
::= { atsCalibrationInput 2 }
|
|
|
|
atsCalibrationInputPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ATSCalibrationInputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of phases per input line to this device."
|
|
::= { atsCalibrationInput 3 }
|
|
|
|
atsCalibrationInputPhaseEntry OBJECT-TYPE
|
|
SYNTAX ATSCalibrationInputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing calibration information applicable to a
|
|
particular input phase."
|
|
INDEX { atsCalibrationInputTableIndex, atsCalibrationInputPhaseTableIndex }
|
|
::= { atsCalibrationInputPhaseTable 1 }
|
|
|
|
ATSCalibrationInputPhaseEntry ::= SEQUENCE {
|
|
atsCalibrationInputTableIndex INTEGER,
|
|
atsCalibrationInputPhaseTableIndex INTEGER,
|
|
atsLineVoltageCalibrationFactor INTEGER
|
|
}
|
|
|
|
atsCalibrationInputTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input identifier."
|
|
::= { atsCalibrationInputPhaseEntry 1 }
|
|
|
|
atsCalibrationInputPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input phase identifier."
|
|
::= { atsCalibrationInputPhaseEntry 2 }
|
|
|
|
atsLineVoltageCalibrationFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Line Voltage Calibration factor.
|
|
This value is set at the factory."
|
|
::= { atsCalibrationInputPhaseEntry 3 }
|
|
|
|
-- Power Supply Voltage Calibration table
|
|
|
|
atsCalibrationPowerSupplyVoltages OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of power supply voltages supported by this device.
|
|
This variable indicates the number of rows in the
|
|
atsCalibrationPowerSupplyTable."
|
|
::= { atsCalibrationPowerSupply 1 }
|
|
|
|
atsCalibrationPowerSupplyVoltageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ATSCalibrationPowerSupplyVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of Power Supply table entries."
|
|
::= { atsCalibrationPowerSupply 2 }
|
|
|
|
atsCalibrationPowerSupplyVoltageEntry OBJECT-TYPE
|
|
SYNTAX ATSCalibrationPowerSupplyVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular Power Supply Voltage."
|
|
INDEX { atsCalibrationPowerSupplyVoltageTableIndex }
|
|
::= { atsCalibrationPowerSupplyVoltageTable 1 }
|
|
|
|
ATSCalibrationPowerSupplyVoltageEntry ::= SEQUENCE {
|
|
atsCalibrationPowerSupplyVoltageTableIndex INTEGER,
|
|
atsCalibrationPowerSupplyVoltage INTEGER,
|
|
atsPowerSupplyVoltageCalibrationFactor INTEGER
|
|
}
|
|
|
|
atsCalibrationPowerSupplyVoltageTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power supply voltage identifier."
|
|
::= { atsCalibrationPowerSupplyVoltageEntry 1 }
|
|
|
|
atsCalibrationPowerSupplyVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerSupply24V(1),
|
|
powerSupply12V(2),
|
|
powerSupply(3),
|
|
powerSupply24VSourceB(4),
|
|
powerSupplyMinus12V(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value describes the power supply voltage of
|
|
24V Source A, 24V Source B, +12V, -12V and 5V."
|
|
::= { atsCalibrationPowerSupplyVoltageEntry 2 }
|
|
|
|
atsPowerSupplyVoltageCalibrationFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Line Voltage Calibration factor.
|
|
This value is set at the factory."
|
|
::= { atsCalibrationPowerSupplyVoltageEntry 3 }
|
|
|
|
-- Output Current Calibration table
|
|
|
|
atsCalibrationNumOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output lines from this device.
|
|
This variable indicates the number of rows in the
|
|
atsCalibrationOutputTable."
|
|
::= { atsCalibrationOutput 1 }
|
|
|
|
atsCalibrationNumOutputPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output phases utilized in this
|
|
device."
|
|
::= { atsCalibrationOutput 2 }
|
|
|
|
atsCalibrationOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ATSCalibrationOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output table entries."
|
|
::= { atsCalibrationOutput 3 }
|
|
|
|
atsCalibrationOutputEntry OBJECT-TYPE
|
|
SYNTAX ATSCalibrationOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output."
|
|
INDEX { atsCalibrationOutputTableIndex, atsCalibrationOutputPhasesTableIndex }
|
|
::= { atsCalibrationOutputTable 1 }
|
|
|
|
ATSCalibrationOutputEntry ::= SEQUENCE {
|
|
atsCalibrationOutputTableIndex INTEGER,
|
|
atsCalibrationOutputPhasesTableIndex INTEGER,
|
|
atsOutputCurrentCalibrationFactor INTEGER
|
|
}
|
|
|
|
atsCalibrationOutputTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output identifier."
|
|
::= { atsCalibrationOutputEntry 1 }
|
|
|
|
atsCalibrationOutputPhasesTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3),
|
|
neutral(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each calibration factor for each
|
|
output phase utilized in this device and one for neutral. "
|
|
::= { atsCalibrationOutputEntry 2 }
|
|
|
|
atsOutputCurrentCalibrationFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output current calibration factor measured in Amps."
|
|
::= { atsCalibrationOutputEntry 3 }
|
|
|
|
|
|
-- the atsControl group
|
|
|
|
atsControlResetATS OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
reset(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable will cause the Automatic Transfer Switch to
|
|
perform a power-on reset."
|
|
::= { atsControl 1 }
|
|
|
|
atsControlClearAllAlarms OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
clear(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable will clear all alarms in the Automatic Transfer Switch.
|
|
Returns (-1) if unsupported."
|
|
::= { atsControl 2 }
|
|
|
|
|
|
-- the atsConfig group
|
|
|
|
atsConfigProductName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A configurable character string."
|
|
::= { atsConfig 1 }
|
|
|
|
atsConfigPreferredSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sourceA(1),
|
|
sourceB(2),
|
|
none(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the preferred source of power when both sources are OK."
|
|
::= { atsConfig 2 }
|
|
|
|
atsConfigFrontPanelLockout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disableFrontPanel(1),
|
|
enableFrontPanel(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable to disableFrontPanel(1), prevents source
|
|
preference configuration of the Automatic Transfer Switch via the
|
|
Front Panel.
|
|
Setting this variable to enableFrontPanel(2)allows, source preference
|
|
configuration of the Automatic Transfer Switch via the Front Panel."
|
|
::= { atsConfig 3 }
|
|
|
|
atsConfigVoltageSensitivity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
high(1),
|
|
low(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable defines the sensitivity to changes in voltage:
|
|
high(1) for best protection, low(2) for frequent small line
|
|
voltage changes."
|
|
::= { atsConfig 4 }
|
|
|
|
atsConfigTransferVoltageRange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wide(1),
|
|
medium(2),
|
|
narrow(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable defines the range of acceptable voltage from a power source.
|
|
If the voltage measured from the selected input source is not within this
|
|
range, the Automatic Transfer Switch will switch over (transfer) to the
|
|
alternate power source."
|
|
|
|
::= { atsConfig 5 }
|
|
|
|
atsConfigCurrentLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (0..20)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The threshold (in Amps) at which an Over Current Alarm will be generated.
|
|
This OID returns the overload threshold value of the
|
|
OID atsConfigPhaseOverLoadThreshold for the 1U ATS and
|
|
OID atsConfigBankOverLoadThreshold of total for the 2U ATS.
|
|
Setting this OID does not have any impact on the device."
|
|
::= { atsConfig 6 }
|
|
|
|
|
|
atsConfigResetValues OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
reset(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Resets the ATS configuration to its default values.
|
|
Returns (-1) if not supported."
|
|
|
|
::= { atsConfig 7 }
|
|
|
|
atsConfigLineVRMS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To configure the input RMS voltage."
|
|
|
|
::= { atsConfig 8 }
|
|
|
|
atsConfigLineVRMSNarrowLimit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To configure the Line VRMS Narrow Limit."
|
|
|
|
::= { atsConfig 9 }
|
|
|
|
atsConfigLineVRMSMediumLimit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To configure the Line VRMS Medium Limit."
|
|
|
|
::= { atsConfig 10 }
|
|
|
|
atsConfigLineVRMSWideLimit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To configure the Line VRMS Wide Limit."
|
|
|
|
::= { atsConfig 11 }
|
|
|
|
atsConfigFrequencyDeviation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
one(1),
|
|
two(2),
|
|
three(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To configure the frequency deviation."
|
|
|
|
::= { atsConfig 12 }
|
|
|
|
-- Bank table
|
|
|
|
atsConfigBankTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the bank table."
|
|
::= { atsConfig 13 }
|
|
|
|
|
|
atsConfigBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ATSConfigBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of each ATS bank."
|
|
::= { atsConfig 14 }
|
|
|
|
atsConfigBankEntry OBJECT-TYPE
|
|
SYNTAX ATSConfigBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to bank current threshold"
|
|
INDEX { atsConfigBankTableIndex }
|
|
::= { atsConfigBankTable 1 }
|
|
|
|
ATSConfigBankEntry ::=
|
|
SEQUENCE {
|
|
atsConfigBankTableIndex INTEGER,
|
|
atsConfigBank INTEGER,
|
|
atsConfigBankLowLoadThreshold INTEGER,
|
|
atsConfigBankNearOverLoadThreshold INTEGER,
|
|
atsConfigBankOverLoadThreshold INTEGER
|
|
}
|
|
|
|
atsConfigBankTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An index to the bank table entry."
|
|
::= { atsConfigBankEntry 1 }
|
|
|
|
atsConfigBank OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
total (1),
|
|
bank1 (2),
|
|
bank2 (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank number of an ATS"
|
|
::= { atsConfigBankEntry 2 }
|
|
|
|
atsConfigBankLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the current drawn is nearing
|
|
a low consumption condition. It is represented in Amps.
|
|
A warning will be issued when the load is less than the
|
|
threshold value.
|
|
|
|
A threshold value of 0 Amps disables this warning.
|
|
|
|
Maximum value must be less than the value returned
|
|
by the atsConfigBankNearOverLoadThreshold OID."
|
|
::= { atsConfigBankEntry 3 }
|
|
|
|
atsConfigBankNearOverLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the current drawn is nearing
|
|
an overload condition. It is represented in Amps.
|
|
A warning will be issued when the load is greater than
|
|
or equal to the threshold value.
|
|
|
|
Minimum value must be greater than the value returned by
|
|
the atsConfigBankLowLoadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the atsConfigBankOverLoadThreshold OID."
|
|
::= { atsConfigBankEntry 4 }
|
|
|
|
atsConfigBankOverLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the current drawn has entered
|
|
an overload condition. It is represented in Amps.
|
|
A warning will be issued when the load is greater than or
|
|
equal to the threshold value.
|
|
|
|
Minimum value must be greater than or equal to the value
|
|
returned by the atsConfigBankNearOverLoadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value returned by
|
|
atsIdentDeviceRating OID."
|
|
::= { atsConfigBankEntry 5 }
|
|
|
|
-- Phase table
|
|
|
|
atsConfigPhaseTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the phase table."
|
|
::= { atsConfig 15 }
|
|
|
|
|
|
atsConfigPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ATSConfigPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of each ATS phase."
|
|
::= { atsConfig 16 }
|
|
|
|
atsConfigPhaseEntry OBJECT-TYPE
|
|
SYNTAX ATSConfigPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to phase threshold"
|
|
INDEX { atsConfigPhaseTableIndex }
|
|
::= { atsConfigPhaseTable 1 }
|
|
|
|
ATSConfigPhaseEntry ::=
|
|
SEQUENCE {
|
|
atsConfigPhaseTableIndex INTEGER,
|
|
atsConfigPhase INTEGER,
|
|
atsConfigPhaseLowLoadThreshold INTEGER,
|
|
atsConfigPhaseNearOverLoadThreshold INTEGER,
|
|
atsConfigPhaseOverLoadThreshold INTEGER
|
|
}
|
|
|
|
atsConfigPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the phase table entry."
|
|
::= { atsConfigPhaseEntry 1 }
|
|
|
|
atsConfigPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase number of an ATS"
|
|
::= { atsConfigPhaseEntry 2 }
|
|
|
|
atsConfigPhaseLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the current drawn is nearing
|
|
a low consumption condition. It is represented in Amps.
|
|
A warning will be issued when the load is less than the
|
|
threshold value.
|
|
|
|
A threshold value of 0 Amps disables this warning.
|
|
|
|
Maximum value must be less than the value returned
|
|
by the atsConfigPhaseNearOverLoadThreshold OID."
|
|
::= { atsConfigPhaseEntry 3 }
|
|
|
|
atsConfigPhaseNearOverLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the current drawn is nearing
|
|
an overload condition. It is represented in Amps.
|
|
A warning will be issued when the load is greater than
|
|
or equal to the threshold value.
|
|
|
|
Minimum value must be greater than the value returned by
|
|
the atsConfigPhaseLowLoadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the atsConfigPhaseOverLoadThreshold OID."
|
|
::= { atsConfigPhaseEntry 4 }
|
|
|
|
atsConfigPhaseOverLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the current drawn has entered
|
|
an overload condition. It is represented in Amps.
|
|
A warning will be issued when the load is greater than or
|
|
equal to the threshold value.
|
|
|
|
Minimum value must be greater than or equal to the value
|
|
returned by the atsConfigPhaseNearOverLoadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by atsIdentDeviceRating OID."
|
|
::= { atsConfigPhaseEntry 5 }
|
|
|
|
|
|
-- the atsStatus group
|
|
|
|
atsStatusCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
atsNeverDiscovered(1),
|
|
atsCommEstablished(2),
|
|
atsCommLost(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the current communication status
|
|
of the Automatic Transfer Switch. "
|
|
::= { atsStatusDeviceStatus 1 }
|
|
|
|
|
|
atsStatusSelectedSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sourceA(1),
|
|
sourceB(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the current source of power. "
|
|
::= { atsStatusDeviceStatus 2 }
|
|
|
|
|
|
atsStatusRedundancyState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
atsRedundancyLost(1),
|
|
atsFullyRedundant(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the current redundancy state of the ATS.
|
|
atsRedundancyLost(1) indicates that the ATS is unable to
|
|
switch over to the alternate power source if the current source fails.
|
|
atsFullyRedundant(2) indicates that the ATS will switch over to
|
|
the alternate power source if the current source fails."
|
|
::= { atsStatusDeviceStatus 3 }
|
|
|
|
|
|
atsStatusOverCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
atsOverCurrent(1),
|
|
atsCurrentOK(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the output current state of the ATS.
|
|
atsOverCurrent(1) indicates that the ATS has exceeded the output
|
|
current threshold and will not allow a switch over to the alternate power
|
|
source if the current source fails.
|
|
atsCurrentOK(2) indicates that the output current is below the
|
|
output current threshold.
|
|
This OID returns the value of the OID atsOutputPhaseState for the 1U ATS and
|
|
OID atsOutputBankState for the 2U ATS."
|
|
::= { atsStatusDeviceStatus 4 }
|
|
|
|
|
|
atsStatus5VPowerSupply OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
atsPowerSupplyFailure(1),
|
|
atsPowerSupplyOK(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the present state of the ATS 5V power supply.
|
|
atsPowerSupplyFailure(1) indicates the 5V power supply has failed
|
|
and that the ATS serial port Configuration Menu is not accessible .
|
|
atsPowerSupplyOK(2) indicates that the ATS 5V power supply
|
|
is operating within tolerance."
|
|
::= { atsStatusDeviceStatus 5 }
|
|
|
|
|
|
atsStatus24VPowerSupply OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
atsPowerSupplyFailure(1),
|
|
atsPowerSupplyOK(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the present state of the ATS 24V power supply for Source A.
|
|
atsPowerSupplyFailure(1) indicates the 24V power supply has failed
|
|
and the ATS is unable to switch over to the alternate power source if
|
|
the current source fails.
|
|
atsPowerSupplyOK(2) indicates that the ATS 24V power supply
|
|
is operating within tolerance."
|
|
::= { atsStatusDeviceStatus 6 }
|
|
|
|
|
|
atsStatus24VSourceBPowerSupply OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
atsPowerSupplyFailure(1),
|
|
atsPowerSupplyOK(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the present state of the ATS 24V power supply for Source B.
|
|
atsPowerSupplyFailure(1) indicates the 24V power supply has failed
|
|
and the ATS is unable to switch over to the alternate power source if
|
|
the current source fails.
|
|
atsPowerSupplyOK(2) indicates that the ATS 24V power supply
|
|
is operating within tolerance."
|
|
::= { atsStatusDeviceStatus 7 }
|
|
|
|
|
|
atsStatusPlus12VPowerSupply OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
atsPowerSupplyFailure(1),
|
|
atsPowerSupplyOK(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the present state of the ATS 12V power supply.
|
|
atsPowerSupplyFailure(1) indicates the 12V power supply has failed
|
|
and the ATS is unable to monitor the current sensors.
|
|
atsPowerSupplyOK(2) indicates that the ATS 12V power supply
|
|
is operating within tolerance."
|
|
::= { atsStatusDeviceStatus 8 }
|
|
|
|
|
|
atsStatusMinus12VPowerSupply OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
atsPowerSupplyFailure(1),
|
|
atsPowerSupplyOK(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the present state of the ATS -12V power supply.
|
|
atsPowerSupplyFailure(1) indicates the -12V power supply has failed
|
|
and the ATS is unable to monitor the current sensors.
|
|
atsPowerSupplyOK(2) indicates that the ATS -12V power supply
|
|
is operating within tolerance."
|
|
::= { atsStatusDeviceStatus 9 }
|
|
|
|
|
|
atsStatusSwitchStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fail(1),
|
|
ok(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of the ATS."
|
|
::= { atsStatusDeviceStatus 10 }
|
|
|
|
|
|
atsStatusFrontPanel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
locked(1),
|
|
unlocked(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the present state of the ATS front panel.
|
|
locked(1): Front panel button cannot be used to change the sources.
|
|
unlocked(2): Front panel button can be used to change the sources. "
|
|
|
|
::= { atsStatusDeviceStatus 11 }
|
|
|
|
|
|
atsStatusSourceAStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fail(1),
|
|
ok(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of the Source A."
|
|
::= { atsStatusDeviceStatus 12 }
|
|
|
|
|
|
atsStatusSourceBStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fail(1),
|
|
ok(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of the Source B."
|
|
::= { atsStatusDeviceStatus 13 }
|
|
|
|
|
|
atsStatusPhaseSyncStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inSync(1),
|
|
outOfSync(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of the phase synch."
|
|
::= { atsStatusDeviceStatus 14 }
|
|
|
|
|
|
atsStatusVoltageOutStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fail(1),
|
|
ok(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the output voltage status."
|
|
::= { atsStatusDeviceStatus 15 }
|
|
|
|
|
|
atsStatusHardwareStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fail(1),
|
|
ok(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of display board hardware."
|
|
::= { atsStatusDeviceStatus 16 }
|
|
|
|
|
|
atsStatusResetMaxMinValues OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
reset(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Resets the maximum and minimum ATS values:
|
|
atsInputMaxVoltage, atsInputMinVoltage,
|
|
atsInputMaxCurrent, atsInputMinCurrent,
|
|
atsInputMaxPower, atsInputMinPower,
|
|
atsOutputMaxCurrent, atsOutputMinCurrent,
|
|
atsOutputMaxLoad, atsOutputMinLoad,
|
|
atsOutputMaxPercentLoad, atsOutputMinPercentLoad,
|
|
atsOutputMaxPower, atsOutputMinPower,
|
|
atsOutputMaxPercentPower, atsOutputMinPercentPower.
|
|
These variables represent the maximum and minimum ATS values
|
|
since the last time they were read or reset by this OID.
|
|
Values unsupported by this ATS will return (-1)."
|
|
::= { atsStatusResetValues 1 }
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
-- Number of Inputs
|
|
atsNumInputs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input feeds to this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { atsStatusInput 1 }
|
|
|
|
-- Input Table
|
|
|
|
atsInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtsInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of atsNumInputs."
|
|
::= { atsStatusInput 2 }
|
|
|
|
atsInputEntry OBJECT-TYPE
|
|
SYNTAX AtsInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input."
|
|
INDEX { atsInputTableIndex }
|
|
::= { atsInputTable 1 }
|
|
|
|
AtsInputEntry ::= SEQUENCE {
|
|
atsInputTableIndex INTEGER,
|
|
atsNumInputPhases INTEGER,
|
|
atsInputVoltageOrientation INTEGER,
|
|
atsInputFrequency INTEGER,
|
|
atsInputType INTEGER,
|
|
atsInputName DisplayString
|
|
}
|
|
|
|
atsInputTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input identifier."
|
|
::= { atsInputEntry 1 }
|
|
|
|
atsNumInputPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input phases utilized in this
|
|
device. The sum of all the atsNumInputPhases
|
|
variable indicates the number of rows in the
|
|
input phase table."
|
|
::= { atsInputEntry 2 }
|
|
|
|
atsInputVoltageOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
singlePhase(2),
|
|
splitPhase(3),
|
|
threePhasePhaseToNeutral(4),
|
|
threePhasePhaseToPhase(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input voltage orientation:
|
|
1: unknown for this Source
|
|
2: singlePhase - phase 1 voltage is between Phase 1
|
|
and Neutral.
|
|
3: splitPhase - phase 1 voltage is between Phase 1 and
|
|
Neutral; phase 2 voltage is between Phase 2 and Neutral;
|
|
phase 3 voltage is between Phase 1 and Phase 2.
|
|
4: threePhasePhaseToNeutral - phase 1 voltage is between
|
|
Phase 1 and Neutral; phase 2 voltage is between Phase 2
|
|
and Neutral; phase 3 voltage is between Phase 3 and
|
|
Neutral.
|
|
5: threePhasePhaseToPhase - phase 1 voltage is between
|
|
Phase 1 and Phase 2; phase 2 voltage is between Phase 2
|
|
and Phase 3; phase 3 voltage is between Phase 3 and
|
|
Phase 1."
|
|
::= { atsInputEntry 3 }
|
|
|
|
atsInputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input frequency in Hertz, or -1 if it's unsupported
|
|
by this Source."
|
|
::= { atsInputEntry 4 }
|
|
|
|
atsInputType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
main(2),
|
|
bypass(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input type."
|
|
::= { atsInputEntry 5 }
|
|
|
|
atsInputName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A name given to a particular input."
|
|
::= { atsInputEntry 6 }
|
|
|
|
-- Input Phase Table
|
|
|
|
atsInputPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtsInputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the sum of the atsNumInputPhases."
|
|
::= { atsStatusInput 3 }
|
|
|
|
atsInputPhaseEntry OBJECT-TYPE
|
|
SYNTAX AtsInputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input phase."
|
|
INDEX { atsInputPhaseTableIndex, atsInputPhaseIndex }
|
|
::= { atsInputPhaseTable 1 }
|
|
|
|
AtsInputPhaseEntry ::= SEQUENCE {
|
|
atsInputPhaseTableIndex INTEGER,
|
|
atsInputPhaseIndex INTEGER,
|
|
atsInputVoltage INTEGER,
|
|
atsInputMaxVoltage INTEGER,
|
|
atsInputMinVoltage INTEGER,
|
|
atsInputCurrent INTEGER,
|
|
atsInputMaxCurrent INTEGER,
|
|
atsInputMinCurrent INTEGER,
|
|
atsInputPower INTEGER,
|
|
atsInputMaxPower INTEGER,
|
|
atsInputMinPower INTEGER
|
|
}
|
|
|
|
atsInputPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input identifier."
|
|
::= { atsInputPhaseEntry 1 }
|
|
|
|
atsInputPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input phase identifier."
|
|
::= { atsInputPhaseEntry 2 }
|
|
|
|
atsInputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input voltage in VAC, or -1 if it's unsupported
|
|
by this Source."
|
|
::= { atsInputPhaseEntry 3 }
|
|
|
|
atsInputMaxVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum input voltage in VAC measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsInputPhaseEntry 4 }
|
|
|
|
atsInputMinVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum input voltage in VAC measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsInputPhaseEntry 5 }
|
|
|
|
atsInputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input current in amperes, or -1 if it's
|
|
unsupported by this Source."
|
|
::= { atsInputPhaseEntry 6 }
|
|
|
|
atsInputMaxCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum input current in amperes measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsInputPhaseEntry 7 }
|
|
|
|
atsInputMinCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum input current in amperes measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsInputPhaseEntry 8 }
|
|
|
|
atsInputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input power in Watts, or -1 if it's unsupported
|
|
by this Source."
|
|
::= { atsInputPhaseEntry 9 }
|
|
|
|
atsInputMaxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum input power in Watts measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsInputPhaseEntry 10 }
|
|
|
|
atsInputMinPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum input power in Watts measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsInputPhaseEntry 11 }
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
-- Number of Outputs
|
|
|
|
atsNumOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output feeds to this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { atsStatusOutput 1 }
|
|
|
|
-- Output Table
|
|
|
|
atsOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtsOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of entries
|
|
is given by the value of atsOutputNumPhases."
|
|
::= { atsStatusOutput 2 }
|
|
|
|
atsOutputEntry OBJECT-TYPE
|
|
SYNTAX AtsOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output."
|
|
INDEX { atsOutputTableIndex }
|
|
::= { atsOutputTable 1 }
|
|
|
|
AtsOutputEntry ::= SEQUENCE {
|
|
atsOutputTableIndex INTEGER,
|
|
atsNumOutputPhases INTEGER,
|
|
atsOutputVoltageOrientation INTEGER,
|
|
atsOutputFrequency INTEGER
|
|
}
|
|
|
|
atsOutputTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output identifier."
|
|
::= { atsOutputEntry 1 }
|
|
|
|
atsNumOutputPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output phases utilized in this
|
|
device. The sum of all the atsNumOutputPhases
|
|
variable indicates the number of rows in the
|
|
output phase table."
|
|
::= { atsOutputEntry 2 }
|
|
|
|
atsOutputVoltageOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
singlePhase(2),
|
|
splitPhase(3),
|
|
threePhasePhaseToNeutral(4),
|
|
threePhasePhaseToPhase(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output voltage orientation:
|
|
1: unknown for this ATS
|
|
2: singlePhase - phase 1 voltage is between Phase 1
|
|
and Neutral.
|
|
3: splitPhase - phase 1 voltage is between Phase 1 and
|
|
Neutral; phase 2 voltage is between Phase 2 and Neutral;
|
|
phase 3 voltage is between Phase 1 and Phase 2.
|
|
4: threePhasePhaseToNeutral - phase 1 voltage is between
|
|
Phase 1 and Neutral; phase 2 voltage is between Phase 2
|
|
and Neutral; phase 3 voltage is between Phase 3 and
|
|
Neutral.
|
|
5: threePhasePhaseToPhase - phase 1 voltage is between
|
|
Phase 1 and Phase 2; phase 2 voltage is between Phase 2
|
|
and Phase 3; phase 3 voltage is between Phase 3 and
|
|
Phase 1."
|
|
::= { atsOutputEntry 3 }
|
|
|
|
atsOutputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output frequency in Hertz, or -1 if it's
|
|
unsupported by this ATS."
|
|
::= { atsOutputEntry 4 }
|
|
|
|
-- Output Phase Table
|
|
|
|
atsOutputPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtsOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the sum of the atsNumOutputPhases."
|
|
::= { atsStatusOutput 3 }
|
|
|
|
atsOutputPhaseEntry OBJECT-TYPE
|
|
SYNTAX AtsOutputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output phase."
|
|
INDEX { atsOutputPhaseTableIndex, atsOutputPhaseIndex }
|
|
::= { atsOutputPhaseTable 1 }
|
|
|
|
AtsOutputPhaseEntry ::= SEQUENCE {
|
|
atsOutputPhaseTableIndex INTEGER,
|
|
atsOutputPhaseIndex INTEGER,
|
|
atsOutputVoltage INTEGER,
|
|
atsOutputCurrent INTEGER,
|
|
atsOutputMaxCurrent INTEGER,
|
|
atsOutputMinCurrent INTEGER,
|
|
atsOutputLoad INTEGER,
|
|
atsOutputMaxLoad INTEGER,
|
|
atsOutputMinLoad INTEGER,
|
|
atsOutputPercentLoad INTEGER,
|
|
atsOutputMaxPercentLoad INTEGER,
|
|
atsOutputMinPercentLoad INTEGER,
|
|
atsOutputPower INTEGER,
|
|
atsOutputMaxPower INTEGER,
|
|
atsOutputMinPower INTEGER,
|
|
atsOutputPercentPower INTEGER,
|
|
atsOutputMaxPercentPower INTEGER,
|
|
atsOutputMinPercentPower INTEGER,
|
|
atsOutputPhaseState INTEGER
|
|
}
|
|
|
|
atsOutputPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output identifier."
|
|
::= { atsOutputPhaseEntry 1 }
|
|
|
|
atsOutputPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3),
|
|
neutral(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each output phase utilized in
|
|
this device and one for neutral. "
|
|
::= { atsOutputPhaseEntry 2 }
|
|
|
|
atsOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output voltage in VAC, or -1 if it's unsupported
|
|
by this ATS."
|
|
::= { atsOutputPhaseEntry 3 }
|
|
|
|
atsOutputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output current in 0.1 amperes drawn
|
|
by the load on the ATS, or -1 if it's unsupported
|
|
by this ATS."
|
|
::= { atsOutputPhaseEntry 4 }
|
|
|
|
atsOutputMaxCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum output current in 0.1 amperes measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputPhaseEntry 5 }
|
|
|
|
atsOutputMinCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum output current in 0.1 amperes measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputPhaseEntry 6 }
|
|
|
|
atsOutputLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output load in VA, or -1 if it's unsupported
|
|
by this ATS."
|
|
::= { atsOutputPhaseEntry 7 }
|
|
|
|
atsOutputMaxLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum output load in VA measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputPhaseEntry 8 }
|
|
|
|
atsOutputMinLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum output load in VA measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputPhaseEntry 9 }
|
|
|
|
atsOutputPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percentage of the ATS load capacity in VA at
|
|
redundancy @ (n + x) presently being used on this
|
|
output phase, or -1 if it's unsupported by this ATS."
|
|
::= { atsOutputPhaseEntry 10 }
|
|
|
|
atsOutputMaxPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum percentage of the ATS load capacity in
|
|
VA measured at redundancy @ (n + x) presently
|
|
being used on this output phase since the last time
|
|
this variable was read or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputPhaseEntry 11 }
|
|
|
|
atsOutputMinPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum percentage of the ATS load capacity in
|
|
VA measured at redundancy @ (n + x) presently
|
|
being used on this output phase since the last time
|
|
this variable was read or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputPhaseEntry 12 }
|
|
|
|
atsOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output power in Watts, or -1 if it's
|
|
unsupported by this ATS."
|
|
::= { atsOutputPhaseEntry 13 }
|
|
|
|
atsOutputMaxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum output power in Watts measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputPhaseEntry 14 }
|
|
|
|
atsOutputMinPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum output power in Watts measured
|
|
since the last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputPhaseEntry 15 }
|
|
|
|
atsOutputPercentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percentage of the ATSpower capacity in Watts at
|
|
redundancy @ (n + x) presently being used on this
|
|
output phase, or -1 if it's unsupported by this ATS."
|
|
::= { atsOutputPhaseEntry 16 }
|
|
|
|
atsOutputMaxPercentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum percentage of the ATSpower capacity
|
|
in Watts measured at redundancy @ (n + x) presently
|
|
being used on this output phase since the last time
|
|
this variable was read or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputPhaseEntry 17 }
|
|
|
|
atsOutputMinPercentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum percentage of the ATSpower capacity
|
|
in Watts measured at redundancy @ (n + x) presently
|
|
being used on this output phase since the last time
|
|
this variable was read or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputPhaseEntry 18 }
|
|
|
|
|
|
atsOutputPhaseState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
lowload (2),
|
|
nearoverload (3),
|
|
overload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase load state.
|
|
|
|
normal(1) indicates that the bank is operating properly
|
|
within the atsConfigPhaseLowLoadThreshold and
|
|
atsConfigPhaseNearOverLoadThreshold OID values.
|
|
|
|
lowload(2) indicates that the bank load has dropped below
|
|
the atsConfigPhaseLowLoadThreshold OID value. An SNMP trap
|
|
will occur when this state is entered or cleared.
|
|
|
|
nearoverload(3) indicates that the bank load is greater than
|
|
or equal to the atsConfigPhaseNearOverLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
overload(4) indicates that the bank load is greater than or
|
|
equal to the atsConfigPhaseOverLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared."
|
|
::= { atsOutputPhaseEntry 19 }
|
|
|
|
|
|
atsOutputBankTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the bank table."
|
|
::= { atsStatusOutput 4 }
|
|
|
|
|
|
atsOutputBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ATSOutputBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting table entries."
|
|
::= { atsStatusOutput 5 }
|
|
|
|
atsOutputBankEntry OBJECT-TYPE
|
|
SYNTAX ATSOutputBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to bank table entries"
|
|
INDEX { atsOutputBankTableIndex }
|
|
::= { atsOutputBankTable 1 }
|
|
|
|
ATSOutputBankEntry ::=
|
|
SEQUENCE {
|
|
atsOutputBankTableIndex INTEGER,
|
|
atsOutputPhase INTEGER,
|
|
atsOutputBank INTEGER,
|
|
atsOutputBankCurrent Gauge,
|
|
atsOutputBankState INTEGER,
|
|
atsOutputBankOutputVoltage INTEGER,
|
|
atsOutputBankMaxCurrent INTEGER,
|
|
atsOutputBankMinCurrent INTEGER,
|
|
atsOutputBankLoad INTEGER,
|
|
atsOutputBankMaxLoad INTEGER,
|
|
atsOutputBankMinLoad INTEGER,
|
|
atsOutputBankPercentLoad INTEGER,
|
|
atsOutputBankMaxPercentLoad INTEGER,
|
|
atsOutputBankMinPercentLoad INTEGER,
|
|
atsOutputBankPower INTEGER,
|
|
atsOutputBankMaxPower INTEGER,
|
|
atsOutputBankMinPower INTEGER,
|
|
atsOutputBankPercentPower INTEGER,
|
|
atsOutputBankMaxPercentPower INTEGER,
|
|
atsOutputBankMinPercentPower INTEGER
|
|
}
|
|
|
|
atsOutputBankTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the bank table entry."
|
|
::= { atsOutputBankEntry 1 }
|
|
|
|
atsOutputPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase number of an ATS"
|
|
::= { atsOutputBankEntry 2 }
|
|
|
|
atsOutputBank OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
total (1),
|
|
bank1 (2),
|
|
bank2 (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank number of an ATS"
|
|
::= { atsOutputBankEntry 3 }
|
|
|
|
atsOutputBankCurrent OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bank current measured
|
|
in tenths of Amps."
|
|
::= { atsOutputBankEntry 4 }
|
|
|
|
atsOutputBankState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
lowload (2),
|
|
nearoverload (3),
|
|
overload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bank load state.
|
|
|
|
normal(1) indicates that the bank is
|
|
operating properly within the atsConfigBankLowLoadThreshold
|
|
and atsConfigBankNearOverLoadThreshold OID values.
|
|
|
|
lowload(2) indicates that the bank load has dropped below the
|
|
atsConfigBankLowLoadThreshold OID value. An SNMP trap will
|
|
occur when this state is entered or cleared.
|
|
|
|
nearoverload(3) indicates that the bank load is greater than
|
|
or equal to the atsConfigBankNearOverLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
overload(4) indicates that the bank load is greater than or
|
|
equal to the atsConfigBankOverLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared."
|
|
::= { atsOutputBankEntry 5 }
|
|
|
|
atsOutputBankOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output voltage in VAC, or -1 if it's unsupported
|
|
by this ATS."
|
|
::= { atsOutputBankEntry 6 }
|
|
|
|
|
|
atsOutputBankMaxCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum output current, on the bank represented by
|
|
OID atsOutputBank, in 0.1 amperes measured since the
|
|
last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputBankEntry 7 }
|
|
|
|
atsOutputBankMinCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum output current, on the bank represented by
|
|
OID atsOutputBank, in 0.1 amperes measured since the
|
|
last time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputBankEntry 8 }
|
|
|
|
atsOutputBankLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output load, on the bank represented by
|
|
OID atsOutputBank, in VA, or -1 if it's
|
|
unsupported by this ATS."
|
|
::= { atsOutputBankEntry 9 }
|
|
|
|
atsOutputBankMaxLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum output load, on the bank represented by
|
|
OID atsOutputBank, in VA measured since the last
|
|
time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputBankEntry 10 }
|
|
|
|
atsOutputBankMinLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum output load, on the bank represented by
|
|
OID atsOutputBank, in VA measured since the last
|
|
time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputBankEntry 11 }
|
|
|
|
atsOutputBankPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percentage of the ATS load capacity in VA at
|
|
redundancy @ (n + x) presently being used on this
|
|
bank, represented by OID atsOutputBank.
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputBankEntry 12 }
|
|
|
|
atsOutputBankMaxPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum percentage of the ATS load capacity in
|
|
VA measured at redundancy @ (n + x) presently
|
|
being used on this bank, represented by OID atsOutputBank,
|
|
since the last time this variable was read or
|
|
reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputBankEntry 13 }
|
|
|
|
atsOutputBankMinPercentLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum percentage of the ATS load capacity in
|
|
VA measured at redundancy @ (n + x) presently
|
|
being used on this bank, represented by OID
|
|
atsOutputBank, since the last time this variable was
|
|
read or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputBankEntry 14 }
|
|
|
|
atsOutputBankPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output power in Watts on the bank represented by
|
|
OID atsOutputBank or -1 if it's unsupported by this ATS."
|
|
::= { atsOutputBankEntry 15 }
|
|
|
|
atsOutputBankMaxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum output power in Watts measured on the bank
|
|
represented by OID atsOutputBank since the last
|
|
time this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputBankEntry 16 }
|
|
|
|
atsOutputBankMinPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum output power in Watts measured on the bank
|
|
represented by OID atsOutputBank since the last time
|
|
this variable was read
|
|
or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputBankEntry 17 }
|
|
|
|
atsOutputBankPercentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percentage of the ATSpower capacity in Watts at
|
|
redundancy @ (n + x) presently being used on this
|
|
bank, represented by OID atsOutputBank, or
|
|
-1 if it's unsupported by this ATS."
|
|
::= { atsOutputBankEntry 18 }
|
|
|
|
atsOutputBankMaxPercentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum percentage of the ATSpower capacity
|
|
in Watts measured at redundancy @ (n + x) presently
|
|
being used on this bank, represented by OID
|
|
atsOutputBank, since the last time this variable
|
|
was read or reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputBankEntry 19 }
|
|
|
|
atsOutputBankMinPercentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum percentage of the ATSpower capacity
|
|
in Watts measured at redundancy @ (n + x) presently
|
|
being used on this bank, represented by OID atsOutputBank
|
|
since the last time this variable was read or
|
|
reset (atsStatusResetMaxMinValues).
|
|
Returns (-1) if unsupported."
|
|
::= { atsOutputBankEntry 20 }
|
|
|
|
|
|
-- the dcmim2IdentSystem group
|
|
|
|
dcmim2IdentSysFWVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Integer representation of the power plant Master Controller firmware revision."
|
|
::= { dcmim2IdentSystem 1 }
|
|
|
|
|
|
-- the dcmim2ControlSystem group
|
|
|
|
dcmim2ControlRunFunctBatteryTest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
battTestOff (1),
|
|
battTestOn (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the battery functional test state. If
|
|
the test is off, the battTestOff (1) value will be returned.
|
|
If the test is on, the battTestOn (2) value will be
|
|
returned.
|
|
|
|
Setting this OID to battTestOff (1) will turn the battery functional test off.
|
|
Setting this OID to battTestOn (2) will turn the battery functional test on."
|
|
|
|
::= { dcmim2ControlSystem 1 }
|
|
|
|
dcmim2ControlRunCapacityBatteryTest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
battTestOff (1),
|
|
battTestOn (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the battery capacity test state. If
|
|
the test is off, the battTestOff (1) value will be returned.
|
|
If the test is on, the battTestOn (2) value will be
|
|
returned.
|
|
|
|
Setting this OID to battTestOff (1) will turn the battery capacity test off.
|
|
Setting this OID to battTestOn (2) will turn the battery capacity test on."
|
|
|
|
::= { dcmim2ControlSystem 2 }
|
|
|
|
|
|
-- the dcmim2ConfigSystem group
|
|
|
|
dcmim2ConfigSysHighTempTrip OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trip level (threshold) at which System High Temp alarm condition is created.
|
|
Range 28 to 100 (degC).
|
|
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
|
|
|
|
|
|
::= { dcmim2ConfigSystem 1 }
|
|
|
|
dcmim2ConfigSysHighTempReset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Level at which System High Temp alarm condition is reset (cleared).
|
|
Range 25 to (upper temp - 3) (degC).
|
|
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
|
|
|
|
::= { dcmim2ConfigSystem 2 }
|
|
|
|
dcmim2ConfigSysLowTempTrip OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trip level (threshold) at which System Low Temp alarm condition is created.
|
|
Range -100 to 10 (degC).
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
|
|
|
|
::= { dcmim2ConfigSystem 3 }
|
|
|
|
dcmim2ConfigSysLowTempReset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Level at which System Low Temp alarm condition is reset (cleared).
|
|
Range (lower temp + 3) to 13 (degC).
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
|
|
|
|
::= { dcmim2ConfigSystem 4 }
|
|
|
|
-- the dcmim2ConfigBattery group
|
|
|
|
dcmim2ConfigBattFloatVolt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Float Voltage defined at 25 degrees Celsius.
|
|
|
|
Values are represented in thousandths of Volts (mV)."
|
|
|
|
::= { dcmim2ConfigBattery 1 }
|
|
|
|
dcmim2ConfigBattMaxRecharge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Maximum Recharge Rate. This is the maximum current used
|
|
during battery charging.
|
|
|
|
Values are represented in thousandths of Amps (mA)."
|
|
|
|
::= { dcmim2ConfigBattery 2 }
|
|
|
|
dcmim2ConfigBattMfgCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery capacity (Amp-Hour Size) as specified by the battery manufacturer.
|
|
|
|
Values are represented in thousandths of Amp hours (mAHr)."
|
|
|
|
::= { dcmim2ConfigBattery 3 }
|
|
|
|
dcmim2ConfigBattType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of battery in the powerplant
|
|
|
|
Valid values range from 0 to 254."
|
|
|
|
::= { dcmim2ConfigBattery 4 }
|
|
|
|
dcmim2ConfigBattFunctTestDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Duration of the battery functional test.
|
|
|
|
Values are represented in thousandths of seconds (mSecs)."
|
|
|
|
::= { dcmim2ConfigBattery 5 }
|
|
|
|
dcmim2ConfigBattFunctTestThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold the battery voltage of the system must remain above
|
|
in order to pass the battery functional test.
|
|
|
|
Values are represented in thousandths of Volts (mV)."
|
|
|
|
::= { dcmim2ConfigBattery 6 }
|
|
|
|
dcmim2ConfigBattCapacityTestPercent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold for good battery capacity test results.
|
|
|
|
Values range from 0 to 100 percent."
|
|
|
|
::= { dcmim2ConfigBattery 7 }
|
|
|
|
dcmim2ConfigBattCapacityTestEndThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Safeguard voltage at which battery capacity test will end
|
|
if there is a battery problem.
|
|
|
|
Values are represented in thousandths of Volts (mV)."
|
|
|
|
::= { dcmim2ConfigBattery 8 }
|
|
|
|
dcmim2ConfigBattCapacityTestCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Constant current value used during battery capacity testing.
|
|
|
|
Values are represented in thousandths of Amps (mA)."
|
|
|
|
::= { dcmim2ConfigBattery 9 }
|
|
|
|
|
|
-- the dcmim2ConfigLVD group
|
|
|
|
dcmim2ConfigLVDTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant LVDs controllable
|
|
by this IP address."
|
|
::= { dcmim2ConfigLVD 1 }
|
|
|
|
dcmim2ConfigLVDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dcmim2ConfigLVDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing settings of the LVDs. The number of
|
|
entries is contained in the dcmim2ConfigLVDTableSize OID."
|
|
::= { dcmim2ConfigLVD 2 }
|
|
|
|
dcmim2ConfigLVDEntry OBJECT-TYPE
|
|
SYNTAX Dcmim2ConfigLVDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The LVD to configure."
|
|
INDEX { dcmim2ConfigLVDIndex }
|
|
::= { dcmim2ConfigLVDTable 1 }
|
|
|
|
Dcmim2ConfigLVDEntry ::=
|
|
SEQUENCE {
|
|
dcmim2ConfigLVDIndex INTEGER,
|
|
dcmim2ConfigLVDTrip INTEGER,
|
|
dcmim2ConfigLVDReset INTEGER,
|
|
dcmim2ConfigLVDState INTEGER
|
|
}
|
|
|
|
dcmim2ConfigLVDIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant LVD."
|
|
::= { dcmim2ConfigLVDEntry 1 }
|
|
|
|
dcmim2ConfigLVDTrip OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LVD Trip threshold. System bus voltage at which LVD will trip (open)
|
|
during a battery backup operation.
|
|
|
|
Values are represented in thousandths of Volts (mV)."
|
|
::= { dcmim2ConfigLVDEntry 2 }
|
|
|
|
dcmim2ConfigLVDReset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LVD Reset threshold. System bus voltage at which LVD will reset (close)
|
|
after AC power has been restored.
|
|
|
|
Values are represented in thousandths of Volts (mV)."
|
|
::= { dcmim2ConfigLVDEntry 3 }
|
|
|
|
dcmim2ConfigLVDState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusClosed (1),
|
|
statusOpened (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusClosed (1) if the LVD is closed.
|
|
statusOpened (2) will be returned if the LVD is opened."
|
|
::= { dcmim2ConfigLVDEntry 4 }
|
|
|
|
|
|
-- the dcmim2StatusSystem group
|
|
|
|
dcmim2StatusSysRectCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System (Total Rectifier) current in thousandths of Amps (mA)."
|
|
::= { dcmim2StatusSystem 1 }
|
|
|
|
dcmim2StatusSysLoadCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Load current in thousandths of Amps (mA)."
|
|
::= { dcmim2StatusSystem 2 }
|
|
|
|
dcmim2StatusSysBusVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System bus voltage in thousandths of Volts (mV)."
|
|
::= { dcmim2StatusSystem 3 }
|
|
|
|
dcmim2StatusSysAmbientTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System temperature based on sensor on Master Controller PCB.
|
|
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { dcmim2StatusSystem 4 }
|
|
|
|
dcmim2StatusSysUpTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Length of time since the DC Powerplant controller has been powered up."
|
|
::= { dcmim2StatusSystem 5 }
|
|
|
|
dcmim2StatusSysTempUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
celsius(1),
|
|
fahrenheit(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature scale used to display the temperature
|
|
in the DC system, Celsius(1) or Fahrenheit(2).
|
|
This setting is based on the system preferences
|
|
configuration in the agent."
|
|
::= { dcmim2StatusSystem 6 }
|
|
|
|
|
|
-- the dcmim2StatusRectifier group
|
|
|
|
dcmim2StatusRectTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant rectifiers viewable
|
|
by this IP address."
|
|
::= { dcmim2StatusRectifier 1 }
|
|
|
|
dcmim2StatusRectTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dcmim2StatusRectEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing settings of the rectifiers. The number of
|
|
entries is contained in the dcmim2StatusRectTableSize OID."
|
|
::= { dcmim2StatusRectifier 2 }
|
|
|
|
dcmim2StatusRectEntry OBJECT-TYPE
|
|
SYNTAX Dcmim2StatusRectEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rectifier to gather status from."
|
|
INDEX { dcmim2StatusRectIndex }
|
|
::= { dcmim2StatusRectTable 1 }
|
|
|
|
Dcmim2StatusRectEntry ::=
|
|
SEQUENCE {
|
|
dcmim2StatusRectIndex INTEGER,
|
|
dcmim2StatusRectDevType INTEGER,
|
|
dcmim2StatusRectID INTEGER,
|
|
dcmim2StatusRectPhyAddr INTEGER,
|
|
dcmim2StatusRectFail INTEGER,
|
|
dcmim2StatusRectCurrent INTEGER
|
|
}
|
|
|
|
dcmim2StatusRectIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant rectifier."
|
|
::= { dcmim2StatusRectEntry 1 }
|
|
|
|
dcmim2StatusRectDevType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier device type."
|
|
::= { dcmim2StatusRectEntry 2 }
|
|
|
|
dcmim2StatusRectID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier ID. This enumerates the number of the rectifier within
|
|
a group of rectifiers."
|
|
::= { dcmim2StatusRectEntry 3 }
|
|
|
|
dcmim2StatusRectPhyAddr OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the rectifier physical address (the address on the bus)."
|
|
::= { dcmim2StatusRectEntry 4 }
|
|
|
|
dcmim2StatusRectFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusTrue (1),
|
|
statusFalse (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusTrue (1) if the rectifier has failed.
|
|
statusFalse (2) will be returned if the rectifier has not failed."
|
|
::= { dcmim2StatusRectEntry 5 }
|
|
|
|
dcmim2StatusRectCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID shows the individual rectifier current in thousandths of Amps (mA)."
|
|
::= { dcmim2StatusRectEntry 6 }
|
|
|
|
|
|
-- the dcmim2StatusBattery group
|
|
|
|
dcmim2StatusBattFloatVolt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Float Voltage represented in thousandths of Volts (mV)."
|
|
::= { dcmim2StatusBattery 1 }
|
|
|
|
dcmim2StatusBattCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Current: This OID shows the battery current in thousandths of Amps (mA)."
|
|
::= { dcmim2StatusBattery 2 }
|
|
|
|
dcmim2StatusBattTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Temperature:
|
|
|
|
Values are represented in thousandths of a degree.
|
|
Units are displayed in the scale shown in
|
|
the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { dcmim2StatusBattery 3 }
|
|
|
|
dcmim2StatusBattMfgCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery capacity (Amp-Hour Size) as specified by the battery manufacturer.
|
|
Values are represented in thousandths of Amp hours (mAHr)."
|
|
::= { dcmim2StatusBattery 4 }
|
|
|
|
dcmim2StatusBattTestCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery capacity (Amp-Hour Size) as determined by the battery capacity test.
|
|
Values are represented in thousandths of Amp hours (mAHr)."
|
|
::= { dcmim2StatusBattery 5 }
|
|
|
|
dcmim2StatusBattFunctTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
functTestNotPerformed (1),
|
|
functTestInProcess (2),
|
|
functTestInterrupted (3),
|
|
functTestPass (4),
|
|
functTestFail (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Results of the last battery functional test that was run."
|
|
::= { dcmim2StatusBattery 6 }
|
|
|
|
dcmim2StatusBattCapacityTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
capacityTestNotPerformed (1),
|
|
capacityTestInProcess (2),
|
|
capacityTestInterrupted (3),
|
|
capacityTestPass (4),
|
|
capacityTestFail (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Results of the last battery capacity test that was run."
|
|
::= { dcmim2StatusBattery 7 }
|
|
|
|
|
|
-- the dcmim2StatusLVD group
|
|
|
|
dcmim2StatusLVDTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant LVDs accessible
|
|
by this IP address."
|
|
::= { dcmim2StatusLVD 1 }
|
|
|
|
dcmim2StatusLVDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dcmim2StatusLVDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing the LVDs. The number of
|
|
entries is contained in the dcmim2StatusLVDTableSize OID."
|
|
::= { dcmim2StatusLVD 2 }
|
|
|
|
dcmim2StatusLVDEntry OBJECT-TYPE
|
|
SYNTAX Dcmim2StatusLVDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The LVD to access."
|
|
INDEX { dcmim2StatusLVDIndex }
|
|
::= { dcmim2StatusLVDTable 1 }
|
|
|
|
Dcmim2StatusLVDEntry ::=
|
|
SEQUENCE {
|
|
dcmim2StatusLVDIndex INTEGER,
|
|
dcmim2StatusLVDState INTEGER
|
|
}
|
|
|
|
dcmim2StatusLVDIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the DC powerplant LVD."
|
|
::= { dcmim2StatusLVDEntry 1 }
|
|
|
|
dcmim2StatusLVDState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusClosed (1),
|
|
statusOpened (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return statusClosed (1) if the LVD is closed.
|
|
statusOpened (2) will be returned if the LVD is opened."
|
|
::= { dcmim2StatusLVDEntry 2 }
|
|
|
|
|
|
-- the dcmim2StatusAlarms group
|
|
|
|
dcmim2StatusAlarmsTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of DC powerplant alarms viewable
|
|
by this IP address."
|
|
::= { dcmim2StatusAlarms 1 }
|
|
|
|
dcmim2StatusAlarmsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dcmim2StatusAlarmsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for accessing system alarms. The number of
|
|
entries is contained in the dcmim2StatusAlarmsTableSize OID."
|
|
::= { dcmim2StatusAlarms 2 }
|
|
|
|
dcmim2StatusAlarmsEntry OBJECT-TYPE
|
|
SYNTAX Dcmim2StatusAlarmsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm to display."
|
|
INDEX { dcmim2StatusAlarmsIndex }
|
|
::= { dcmim2StatusAlarmsTable 1 }
|
|
|
|
Dcmim2StatusAlarmsEntry ::=
|
|
SEQUENCE {
|
|
dcmim2StatusAlarmsIndex INTEGER,
|
|
dcmim2StatusAlarmsText DisplayString
|
|
}
|
|
|
|
dcmim2StatusAlarmsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the system alarm."
|
|
::= { dcmim2StatusAlarmsEntry 1 }
|
|
|
|
dcmim2StatusAlarmsText OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The 16 character text describing the active alarm condition."
|
|
::= { dcmim2StatusAlarmsEntry 2 }
|
|
|
|
-- External Environmental Monitor
|
|
|
|
emIdentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the Environmental Monitor."
|
|
::= { emIdent 1 }
|
|
|
|
emConfigProbesNumProbes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of temperature and humidity probes available."
|
|
::= { emConfig 1 }
|
|
|
|
emConfigProbesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EmConfigProbesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of probes supported by the Environmental Monitor
|
|
and their configurations."
|
|
::= { emConfig 2 }
|
|
|
|
emConfigProbesEntry OBJECT-TYPE
|
|
SYNTAX EmConfigProbesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Environmental Monitor probe configurations."
|
|
INDEX { emConfigProbeNumber }
|
|
::= { emConfigProbesTable 1 }
|
|
|
|
EmConfigProbesEntry ::=
|
|
SEQUENCE {
|
|
emConfigProbeNumber
|
|
INTEGER,
|
|
emConfigProbeName
|
|
DisplayString,
|
|
emConfigProbeHighTempThreshold
|
|
INTEGER,
|
|
emConfigProbeLowTempThreshold
|
|
INTEGER,
|
|
emConfigProbeTempUnits
|
|
INTEGER,
|
|
emConfigProbeHighHumidThreshold
|
|
INTEGER,
|
|
emConfigProbeLowHumidThreshold
|
|
INTEGER,
|
|
emConfigProbeHighTempEnable
|
|
INTEGER,
|
|
emConfigProbeLowTempEnable
|
|
INTEGER,
|
|
emConfigProbeHighHumidEnable
|
|
INTEGER,
|
|
emConfigProbeLowHumidEnable
|
|
INTEGER,
|
|
emConfigProbeMaxTempThreshold
|
|
INTEGER,
|
|
emConfigProbeMinTempThreshold
|
|
INTEGER,
|
|
emConfigProbeMaxHumidThreshold
|
|
INTEGER,
|
|
emConfigProbeMinHumidThreshold
|
|
INTEGER,
|
|
emConfigProbeMaxTempEnable
|
|
INTEGER,
|
|
emConfigProbeMinTempEnable
|
|
INTEGER,
|
|
emConfigProbeMaxHumidEnable
|
|
INTEGER,
|
|
emConfigProbeMinHumidEnable
|
|
INTEGER,
|
|
emConfigProbeTempHysteresis
|
|
INTEGER,
|
|
emConfigProbeHumidHysteresis
|
|
INTEGER,
|
|
emConfigProbeLocation
|
|
DisplayString
|
|
}
|
|
|
|
emConfigProbeNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into an Environmental Monitor probe entry."
|
|
::= { emConfigProbesEntry 1 }
|
|
|
|
emConfigProbeName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name of the probe set by the user,
|
|
possibly denoting its location or purpose."
|
|
::= { emConfigProbesEntry 2 }
|
|
|
|
emConfigProbeHighTempThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature alarm threshold for the probe.
|
|
Units are displayed in the scale selected in
|
|
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { emConfigProbesEntry 3 }
|
|
|
|
emConfigProbeLowTempThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature alarm threshold for the probe.
|
|
Units are displayed in the scale selected in
|
|
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { emConfigProbesEntry 4 }
|
|
|
|
emConfigProbeTempUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
celsius(1),
|
|
fahrenheit(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature scale used to display the temperature
|
|
thresholds of the probe, Celsius(1) or Fahrenheit(2).
|
|
This setting is based on the system preferences
|
|
configuration in the agent."
|
|
::= { emConfigProbesEntry 5 }
|
|
|
|
emConfigProbeHighHumidThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high humidity alarm threshold for the probe in
|
|
percent relative humidity."
|
|
::= { emConfigProbesEntry 6 }
|
|
|
|
emConfigProbeLowHumidThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low humidity alarm threshold for the probe in
|
|
percent relative humidity."
|
|
::= { emConfigProbesEntry 7 }
|
|
|
|
emConfigProbeHighTempEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { emConfigProbesEntry 8 }
|
|
|
|
emConfigProbeLowTempEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { emConfigProbesEntry 9 }
|
|
|
|
emConfigProbeHighHumidEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high humidity alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { emConfigProbesEntry 10 }
|
|
|
|
emConfigProbeLowHumidEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low humidity alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { emConfigProbesEntry 11 }
|
|
|
|
emConfigProbeMaxTempThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum temperature alarm threshold for the probe.
|
|
Units are displayed in the scale selected in
|
|
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { emConfigProbesEntry 12 }
|
|
|
|
emConfigProbeMinTempThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum temperature alarm threshold for the probe.
|
|
Units are displayed in the scale selected in
|
|
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { emConfigProbesEntry 13 }
|
|
|
|
emConfigProbeMaxHumidThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximun humidity alarm threshold for the probe in
|
|
percent relative humidity."
|
|
::= { emConfigProbesEntry 14 }
|
|
|
|
emConfigProbeMinHumidThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum humidity alarm threshold for the probe in
|
|
percent relative humidity."
|
|
::= { emConfigProbesEntry 15 }
|
|
|
|
emConfigProbeMaxTempEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum temperature alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { emConfigProbesEntry 16 }
|
|
|
|
emConfigProbeMinTempEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum temperature alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { emConfigProbesEntry 17 }
|
|
|
|
emConfigProbeMaxHumidEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum humidity alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { emConfigProbesEntry 18 }
|
|
|
|
emConfigProbeMinHumidEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum humidity alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { emConfigProbesEntry 19 }
|
|
|
|
emConfigProbeTempHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees beyond the temperature thresholds
|
|
at which an active temperature alarm will be cleared.
|
|
This configuration setting applies to all temperature
|
|
thresholds.
|
|
Units are displayed in the scale selected in
|
|
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { emConfigProbesEntry 20 }
|
|
|
|
emConfigProbeHumidHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of percent RH points beyond the humidity
|
|
thresholds at which an active humidity alarm will be
|
|
cleared. This configuration setting applies to all
|
|
humidity thresholds.
|
|
Units are displayed in the scale selected in
|
|
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { emConfigProbesEntry 21 }
|
|
|
|
emConfigProbeLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string describing the location of the probe."
|
|
::= { emConfigProbesEntry 22 }
|
|
|
|
emConfigContactsNumContacts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of contacts supported by the Environmental
|
|
Monitor."
|
|
::= { emConfig 3 }
|
|
|
|
emConfigContactsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EmConfigContactsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of contacts supported by the Environmental Monitor
|
|
and their configurations."
|
|
::= { emConfig 4 }
|
|
|
|
emConfigContactsEntry OBJECT-TYPE
|
|
SYNTAX EmConfigContactsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Environmental Monitor contact configurations."
|
|
INDEX { emConfigContactNumber }
|
|
::= { emConfigContactsTable 1 }
|
|
|
|
EmConfigContactsEntry ::=
|
|
SEQUENCE {
|
|
emConfigContactNumber
|
|
INTEGER,
|
|
emConfigContactName
|
|
DisplayString,
|
|
emConfigContactEnable
|
|
INTEGER,
|
|
emConfigContactSeverity
|
|
INTEGER,
|
|
emConfigContactNormalState
|
|
INTEGER,
|
|
emConfigContactLocation
|
|
DisplayString
|
|
}
|
|
|
|
emConfigContactNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of an Environmental Monitor contact."
|
|
::= { emConfigContactsEntry 1 }
|
|
|
|
emConfigContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for an Environmental Monitor
|
|
contact set by the user, possibly denoting its
|
|
location or purpose."
|
|
::= { emConfigContactsEntry 2 }
|
|
|
|
emConfigContactEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An Environmental Monitor contact alarm enable/disable.
|
|
No alarm will be generated if the contact is disabled(1).
|
|
An alarm will be generated if the contact is enabled(2)
|
|
and the contact has been faulted."
|
|
::= { emConfigContactsEntry 3 }
|
|
|
|
emConfigContactSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical(1),
|
|
warning(2),
|
|
informational(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The severity of the alarm that will be triggered when
|
|
the input contact is activated. The alarms can be
|
|
critical(1), warning(2) or informational(3)."
|
|
::= { emConfigContactsEntry 4 }
|
|
|
|
emConfigContactNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open(1),
|
|
closed(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The contact state that will be considered normal, i.e.
|
|
will not trigger an alarm. The states are open(1) or
|
|
closed(2)."
|
|
::= { emConfigContactsEntry 5 }
|
|
|
|
emConfigContactLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive label for the contact denoting its
|
|
location or purpose."
|
|
::= { emConfigContactsEntry 6 }
|
|
|
|
emStatusCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noComm(1),
|
|
comm(2),
|
|
commLost(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The communication status between the agent
|
|
and the Environmental Monitor.
|
|
|
|
noComm(1), Communication has never been established.
|
|
comm(2), Communication has been established.
|
|
commLost(3), Communication was established, but was lost."
|
|
::= { emStatus 1 }
|
|
|
|
emStatusProbesNumProbes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of available probes on the Environmental
|
|
Monitor."
|
|
::= { emStatus 2 }
|
|
|
|
emStatusProbesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EmStatusProbesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of probes supported by the Environmental Monitor
|
|
and their status."
|
|
::= { emStatus 3 }
|
|
|
|
emStatusProbesEntry OBJECT-TYPE
|
|
SYNTAX EmStatusProbesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the probe."
|
|
INDEX { emStatusProbeNumber }
|
|
::= { emStatusProbesTable 1 }
|
|
|
|
EmStatusProbesEntry ::=
|
|
SEQUENCE {
|
|
emStatusProbeNumber
|
|
INTEGER,
|
|
emStatusProbeName
|
|
DisplayString,
|
|
emStatusProbeStatus
|
|
INTEGER,
|
|
emStatusProbeCurrentTemp
|
|
INTEGER,
|
|
emStatusProbeTempUnits
|
|
INTEGER,
|
|
emStatusProbeCurrentHumid
|
|
INTEGER,
|
|
emStatusProbeHighTempViolation
|
|
INTEGER,
|
|
emStatusProbeLowTempViolation
|
|
INTEGER,
|
|
emStatusProbeHighHumidViolation
|
|
INTEGER,
|
|
emStatusProbeLowHumidViolation
|
|
INTEGER,
|
|
emStatusProbeMaxTempViolation
|
|
INTEGER,
|
|
emStatusProbeMinTempViolation
|
|
INTEGER,
|
|
emStatusProbeMaxHumidViolation
|
|
INTEGER,
|
|
emStatusProbeMinHumidViolation
|
|
INTEGER
|
|
}
|
|
|
|
emStatusProbeNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the probe."
|
|
::= { emStatusProbesEntry 1 }
|
|
|
|
emStatusProbeName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for the probe set by the user,
|
|
possibly denoting its location or purpose."
|
|
::= { emStatusProbesEntry 2 }
|
|
|
|
emStatusProbeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disconnected(1),
|
|
connected(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The connected status of the probe, either
|
|
disconnected(1) or connected(2)."
|
|
::= { emStatusProbesEntry 3 }
|
|
|
|
emStatusProbeCurrentTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current temperature reading from the probe displayed
|
|
in the units shown in the 'emStatusProbeTempUnits' OID
|
|
(Celsius or Fahrenheit)."
|
|
::= { emStatusProbesEntry 4 }
|
|
|
|
emStatusProbeTempUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
celsius(1),
|
|
fahrenheit(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature scale used to display the temperature
|
|
thresholds of the probe, Celsius(1) or Fahrenheit(2).
|
|
This setting is based on the system preferences
|
|
configuration in the agent."
|
|
::= { emStatusProbesEntry 5 }
|
|
|
|
emStatusProbeCurrentHumid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current humidity reading from the probe in
|
|
percent relative humidity."
|
|
::= { emStatusProbesEntry 6 }
|
|
|
|
emStatusProbeHighTempViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
highTempViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature violation status of the probe
|
|
temperature reading. This OID will show a highTempViolation(2)
|
|
if the current temperature reading shown in the
|
|
'emStatusProbeCurrentTemp' OID is greater than or equal to
|
|
the high temperature threshold value, the
|
|
'emConfigProbeHighTempThreshold' OID, and the value of the
|
|
'emConfigProbeHighTempEnable' OID is enabled. Otherwise it will show
|
|
noViolation(1). If the 'emConfigProbeHighTempEnable' OID is disabled,
|
|
this OID will show disabled(3)."
|
|
::= { emStatusProbesEntry 7 }
|
|
|
|
emStatusProbeLowTempViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
lowTempViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature violation status of the probe
|
|
temperature reading. This OID will show a lowTempViolation(2)
|
|
if the current temperature reading shown in the
|
|
'emStatusProbeCurrentTemp' OID is less than or equal to
|
|
the low temperature threshold value, the
|
|
'emConfigProbeLowTempThreshold' OID, and the value of the
|
|
'emConfigProbeLowTempEnable' OID is enabled. Otherwise it will show
|
|
noViolation(1). If the 'emConfigProbeLowTempEnable' OID is disabled,
|
|
this OID will show disabled(3)."
|
|
::= { emStatusProbesEntry 8 }
|
|
|
|
emStatusProbeHighHumidViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
highHumidViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high humidity violation status of the probe humidity
|
|
reading. This OID will show a highTempViolation(2)
|
|
if the current humidity reading shown in the
|
|
'emStatusProbeCurrentHumid' OID is greater than or equal to
|
|
the high humidity threshold value, the
|
|
'emConfigProbeHighHumidThreshold' OID, and the value of the
|
|
'emConfigProbeHighHumidEnable' OID is enabled. Otherwise it will
|
|
show noViolation(1). If the 'emConfigProbeHighHumidEnable' OID is
|
|
disabled, this OID will show disabled(3)"
|
|
::= { emStatusProbesEntry 9 }
|
|
|
|
emStatusProbeLowHumidViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
lowHumidViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low humidity violation status of the probe humidity
|
|
reading. This OID will show a lowTempViolation(2)
|
|
if the current humidity reading shown in the
|
|
'emStatusProbeCurrentHumid' OID is less than or equal to
|
|
the low humidity threshold value, the
|
|
'emConfigProbeLowHumidThreshold' OID, and the value of the
|
|
'emConfigProbeLowHumidEnable' OID is enabled. Otherwise it will
|
|
show noViolation(1). If the 'emConfigProbeLowHumidEnable' OID is
|
|
disabled, this OID will show disabled(3)."
|
|
::= { emStatusProbesEntry 10 }
|
|
|
|
emStatusProbeMaxTempViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
maxTempViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The max temperature violation status of the probe
|
|
temperature reading. This OID will show a maxTempViolation(2)
|
|
if the current temperature reading shown in the
|
|
'emStatusProbeCurrentTemp' OID is greater than or equal to
|
|
the maximun temperature threshold value, the
|
|
'emConfigProbeMaxTempThreshold' OID, and the value of the
|
|
'emConfigProbeMaxTempEnable' OID is enabled. Otherwise it will show
|
|
noViolation(1). If the 'emConfigProbeMaxTempEnable' OID is disabled,
|
|
this OID will show disabled(3)."
|
|
::= { emStatusProbesEntry 11 }
|
|
|
|
emStatusProbeMinTempViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
minTempViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum temperature violation status of the probe
|
|
temperature reading. This OID will show a minTempViolation(2)
|
|
if the current temperature reading shown in the
|
|
'emStatusProbeCurrentTemp' OID is less than or equal to
|
|
the minimum temperature threshold value, the
|
|
'emConfigProbeMinTempThreshold' OID, and the value of the
|
|
'emConfigProbeMinTempEnable' OID is enabled. Otherwise it will show
|
|
noViolation(1). If the 'emConfigProbeMinTempEnable' OID is disabled,
|
|
this OID will show disabled(3)."
|
|
::= { emStatusProbesEntry 12 }
|
|
|
|
emStatusProbeMaxHumidViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
maxHumidViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum humidity violation status of the probe humidity
|
|
reading. This OID will show a maxTempViolation(2)
|
|
if the current humidity reading shown in the
|
|
'emStatusProbeCurrentHumid' OID is greater than or equal to
|
|
the maximum humidity threshold value, the
|
|
'emConfigProbeMaxHumidThreshold' OID, and the value of the
|
|
'emConfigProbeMaxHumidEnable' OID is enabled. Otherwise it will
|
|
show noViolation(1). If the 'emConfigProbeMaxHumidEnable' OID is
|
|
disabled, this OID will show disabled(3)"
|
|
::= { emStatusProbesEntry 13 }
|
|
|
|
emStatusProbeMinHumidViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
minHumidViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum humidity violation status of the probe humidity
|
|
reading. This OID will show a minTempViolation(2)
|
|
if the current humidity reading shown in the
|
|
'emStatusProbeCurrentHumid' OID is less than or equal to
|
|
the minimum humidity threshold value, the
|
|
'emConfigProbeMinHumidThreshold' OID, and the value of the
|
|
'emConfigProbeMinHumidEnable' OID is enabled. Otherwise it will
|
|
show noViolation(1). If the 'emConfigProbeMinHumidEnable' OID is
|
|
disabled, this OID will show disabled(3)."
|
|
::= { emStatusProbesEntry 14 }
|
|
|
|
emStatusContactsNumContacts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of contacts supported by the
|
|
Environmental Monitor."
|
|
::= { emStatus 4 }
|
|
|
|
emStatusContactsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EmStatusContactsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of contacts supported by the Environmental Monitor
|
|
and their status."
|
|
::= { emStatus 5 }
|
|
|
|
emStatusContactsEntry OBJECT-TYPE
|
|
SYNTAX EmStatusContactsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the contact."
|
|
INDEX { emStatusContactNumber }
|
|
::= { emStatusContactsTable 1 }
|
|
|
|
EmStatusContactsEntry ::=
|
|
SEQUENCE {
|
|
emStatusContactNumber
|
|
INTEGER,
|
|
emStatusContactName
|
|
DisplayString,
|
|
emStatusContactStatus
|
|
INTEGER
|
|
}
|
|
|
|
emStatusContactNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the Environmental Monitor contact."
|
|
::= { emStatusContactsEntry 1 }
|
|
|
|
emStatusContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for the Environmental Monitor contact
|
|
set by the user, possibly denoting its location or purpose."
|
|
::= { emStatusContactsEntry 2 }
|
|
|
|
emStatusContactStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noFault(1),
|
|
fault(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Environmental Monitor contact. The status
|
|
will show noFault(1) if the contact is in the normal state
|
|
and the 'emConfigContactEnable' OID is enabled. The status will
|
|
show a fault(2) if the contact is faulted and the
|
|
'emContactEnable' OID is enabled. If the 'emConfigContactEnable'
|
|
OID is disabled, the status will show disabled(3)."
|
|
::= { emStatusContactsEntry 3 }
|
|
|
|
-- Modular Environmental Manager (MEM)
|
|
|
|
-- MEM Modules Status table
|
|
|
|
memModulesStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memModulesStatusTable."
|
|
::= { memModules 1 }
|
|
|
|
memModulesStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemModulesStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting status information from the modules
|
|
attached to the system."
|
|
::= { memModules 2 }
|
|
|
|
memModulesStatusEntry OBJECT-TYPE
|
|
SYNTAX MemModulesStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memModulesStatusModuleNumber }
|
|
::= { memModulesStatusTable 1 }
|
|
|
|
MemModulesStatusEntry ::=
|
|
SEQUENCE {
|
|
memModulesStatusModuleNumber INTEGER,
|
|
memModulesStatusModuleName DisplayString,
|
|
memModulesStatusModuleLocation DisplayString,
|
|
memModulesStatusModelNumber DisplayString,
|
|
memModulesStatusSerialNumber DisplayString,
|
|
memModulesStatusFirmwareRev DisplayString,
|
|
memModulesStatusHardwareRev DisplayString
|
|
}
|
|
|
|
memModulesStatusModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module number."
|
|
::= { memModulesStatusEntry 1 }
|
|
|
|
memModulesStatusModuleName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module name."
|
|
::= { memModulesStatusEntry 2 }
|
|
|
|
memModulesStatusModuleLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the module."
|
|
::= { memModulesStatusEntry 3 }
|
|
|
|
memModulesStatusModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The model number of the module."
|
|
::= { memModulesStatusEntry 4 }
|
|
|
|
memModulesStatusSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the module."
|
|
::= { memModulesStatusEntry 5 }
|
|
|
|
memModulesStatusFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the module."
|
|
::= { memModulesStatusEntry 6 }
|
|
|
|
memModulesStatusHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision."
|
|
::= { memModulesStatusEntry 7 }
|
|
|
|
-- MEM Modules Config table
|
|
|
|
memModulesConfigTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memModulesConfigTable."
|
|
::= { memModules 3 }
|
|
|
|
memModulesConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemModulesConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting status information from the modules
|
|
attached to the system."
|
|
::= { memModules 4 }
|
|
|
|
memModulesConfigEntry OBJECT-TYPE
|
|
SYNTAX MemModulesConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memModulesConfigModuleNumber }
|
|
::= { memModulesConfigTable 1 }
|
|
|
|
MemModulesConfigEntry ::=
|
|
SEQUENCE {
|
|
memModulesConfigModuleNumber INTEGER,
|
|
memModulesConfigModuleName DisplayString,
|
|
memModulesConfigModuleLocation DisplayString
|
|
}
|
|
|
|
memModulesConfigModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module number."
|
|
::= { memModulesConfigEntry 1 }
|
|
|
|
memModulesConfigModuleName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module name."
|
|
::= { memModulesConfigEntry 2 }
|
|
|
|
memModulesConfigModuleLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the module."
|
|
::= { memModulesConfigEntry 3 }
|
|
|
|
|
|
-- MEM Sensor Status Table
|
|
|
|
memSensorsStatusSysTempUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
celsius(1),
|
|
fahrenheit(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature scale used to display the temperature
|
|
in the system, Celsius(1) or Fahrenheit(2).
|
|
This setting is based on the system preferences
|
|
configuration in the agent."
|
|
::= { memSensors 1 }
|
|
|
|
memSensorsStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memSensorsStatusTable."
|
|
::= { memSensors 2 }
|
|
|
|
memSensorsStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemSensorsStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting sensor status information."
|
|
::= { memSensors 3 }
|
|
|
|
memSensorsStatusEntry OBJECT-TYPE
|
|
SYNTAX MemSensorsStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memSensorsStatusModuleNumber, memSensorsStatusSensorNumber }
|
|
::= { memSensorsStatusTable 1 }
|
|
|
|
MemSensorsStatusEntry ::=
|
|
SEQUENCE {
|
|
memSensorsStatusModuleNumber INTEGER,
|
|
memSensorsStatusSensorNumber INTEGER,
|
|
memSensorsStatusSensorName DisplayString,
|
|
memSensorsStatusSensorLocation DisplayString,
|
|
memSensorsTemperature INTEGER,
|
|
memSensorsHumidity INTEGER,
|
|
memSensorsCommStatus INTEGER,
|
|
memSensorsAlarmStatus INTEGER
|
|
}
|
|
|
|
memSensorsStatusModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the module that the sensor is attached to."
|
|
::= { memSensorsStatusEntry 1 }
|
|
|
|
memSensorsStatusSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of this sensor on the module."
|
|
::= { memSensorsStatusEntry 2 }
|
|
|
|
memSensorsStatusSensorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor name."
|
|
::= { memSensorsStatusEntry 3 }
|
|
|
|
memSensorsStatusSensorLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the sensor."
|
|
::= { memSensorsStatusEntry 4 }
|
|
|
|
memSensorsTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor's current temperature reading.
|
|
Units are displayed in the scale shown in
|
|
the memSensorsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { memSensorsStatusEntry 5 }
|
|
|
|
memSensorsHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current humidity reading from the sensor."
|
|
::= { memSensorsStatusEntry 6 }
|
|
|
|
memSensorsCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notInstalled(1),
|
|
commsOK(2),
|
|
commsLost(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The communications status of the sensor."
|
|
::= { memSensorsStatusEntry 7 }
|
|
|
|
memSensorsAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
memNormal(1),
|
|
memWarning(2),
|
|
memCritical(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm status of the sensor."
|
|
::= { memSensorsStatusEntry 8 }
|
|
|
|
|
|
-- MEM Sensor Config Table
|
|
|
|
memSensorsConfigTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memSensorsConfigTable."
|
|
::= { memSensors 4 }
|
|
|
|
memSensorsConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemSensorsConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting configuration information from
|
|
sensors attached to the system."
|
|
::= { memSensors 5 }
|
|
|
|
memSensorsConfigEntry OBJECT-TYPE
|
|
SYNTAX MemSensorsConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memSensorsConfigModuleNumber, memSensorsConfigSensorNumber }
|
|
::= { memSensorsConfigTable 1 }
|
|
|
|
MemSensorsConfigEntry ::=
|
|
SEQUENCE {
|
|
memSensorsConfigModuleNumber INTEGER,
|
|
memSensorsConfigSensorNumber INTEGER,
|
|
memSensorsName DisplayString,
|
|
memSensorsLocation DisplayString,
|
|
memSensorsAlarmGeneration INTEGER,
|
|
memSensorsTempMaxThresh INTEGER,
|
|
memSensorsTempHighThresh INTEGER,
|
|
memSensorsTempLowThresh INTEGER,
|
|
memSensorsTempMinThresh INTEGER,
|
|
memSensorsTempThreshHysteresis INTEGER,
|
|
memSensorsTempShortDecRateThreshValue INTEGER,
|
|
memSensorsTempShortDecRateThreshTime INTEGER,
|
|
memSensorsTempShortIncRateThreshValue INTEGER,
|
|
memSensorsTempShortIncRateThreshTime INTEGER,
|
|
memSensorsTempLongDecRateThreshValue INTEGER,
|
|
memSensorsTempLongDecRateThreshTime INTEGER,
|
|
memSensorsTempLongIncRateThreshValue INTEGER,
|
|
memSensorsTempLongIncRateThreshTime INTEGER,
|
|
memSensorsHumidityMaxThresh INTEGER,
|
|
memSensorsHumidityHighThresh INTEGER,
|
|
memSensorsHumidityLowThresh INTEGER,
|
|
memSensorsHumidityMinThresh INTEGER,
|
|
memSensorsHumidityThreshHysteresis INTEGER
|
|
}
|
|
|
|
memSensorsConfigModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the module that the sensor is attached to."
|
|
::= { memSensorsConfigEntry 1 }
|
|
|
|
memSensorsConfigSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of this sensor on the module."
|
|
::= { memSensorsConfigEntry 2 }
|
|
|
|
memSensorsName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for the sensor."
|
|
::= { memSensorsConfigEntry 3 }
|
|
|
|
memSensorsLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the sensor."
|
|
::= { memSensorsConfigEntry 4 }
|
|
|
|
memSensorsAlarmGeneration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable alarm generation on this sensor."
|
|
::= { memSensorsConfigEntry 5 }
|
|
|
|
memSensorsTempMaxThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature at which the MEM will generate a maximum
|
|
temperature threshold violation alarm on this sensor.
|
|
The temperature scale is based on the memSensorsStatusSysTempUnits OID."
|
|
|
|
::= { memSensorsConfigEntry 6 }
|
|
|
|
memSensorsTempHighThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature at which the MEM will generate a high
|
|
temperature threshold violation alarm on this sensor.
|
|
The temperature scale is based on the memSensorsStatusSysTempUnits OID."
|
|
::= { memSensorsConfigEntry 7 }
|
|
|
|
memSensorsTempLowThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature at which the MEM will generate a low
|
|
temperature threshold violation alarm on this sensor.
|
|
The temperature scale is based on the memSensorsStatusSysTempUnits OID."
|
|
::= { memSensorsConfigEntry 8 }
|
|
|
|
memSensorsTempMinThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature at which the MEM will generate a minimum
|
|
temperature threshold violation alarm on this sensor.
|
|
The temperature scale is based on the memSensorsStatusSysTempUnits OID."
|
|
::= { memSensorsConfigEntry 9 }
|
|
|
|
memSensorsTempThreshHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The change in temperature required to cause a
|
|
temperature alarm to change from an active to an inactive state.
|
|
The temperature scale is based on the memSensorsStatusSysTempUnits OID."
|
|
|
|
::= { memSensorsConfigEntry 10 }
|
|
|
|
memSensorsTempShortDecRateThreshValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the temperature short-term decreasing rate
|
|
time that will cause an alarm to be generated.
|
|
The temperature scale is based on the memSensorsStatusSysTempUnits OID."
|
|
::= { memSensorsConfigEntry 11 }
|
|
|
|
memSensorsTempShortDecRateThreshTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time over which the temperature may not decrease
|
|
beyond the value specified by the temperature short-term
|
|
decreasing rate threshold value."
|
|
::= { memSensorsConfigEntry 12 }
|
|
|
|
memSensorsTempShortIncRateThreshValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the temperature short-term increasing rate
|
|
time that will cause an alarm to be generated.
|
|
The temperature scale is based on the memSensorsStatusSysTempUnits OID."
|
|
::= { memSensorsConfigEntry 13 }
|
|
|
|
memSensorsTempShortIncRateThreshTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time over which the temperature may not increase
|
|
beyond the value specified by the temperature short-term
|
|
increasing rate threshold value."
|
|
::= { memSensorsConfigEntry 14 }
|
|
|
|
memSensorsTempLongDecRateThreshValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the temperature long-term decreasing rate
|
|
time that will cause an alarm to be generated.
|
|
The temperature scale is based on the memSensorsStatusSysTempUnits OID."
|
|
::= { memSensorsConfigEntry 15 }
|
|
|
|
memSensorsTempLongDecRateThreshTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time over which the temperature may not decrease
|
|
beyond the value specified by the temperature long-term
|
|
decreasing rate threshold value."
|
|
::= { memSensorsConfigEntry 16 }
|
|
|
|
memSensorsTempLongIncRateThreshValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the temperature long-term increasing rate
|
|
time that will cause an alarm to be generated.
|
|
The temperature scale is based on the memSensorsStatusSysTempUnits OID."
|
|
::= { memSensorsConfigEntry 17 }
|
|
|
|
memSensorsTempLongIncRateThreshTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time over which the temperature may not increase
|
|
beyond the value specified by the temperature long-term
|
|
increasing rate threshold value."
|
|
::= { memSensorsConfigEntry 18 }
|
|
|
|
memSensorsHumidityMaxThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidity at which the maximum humidity threshold alarm
|
|
will be generated."
|
|
::= { memSensorsConfigEntry 19 }
|
|
|
|
memSensorsHumidityHighThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidity at which the high humidity threshold alarm
|
|
will be generated."
|
|
::= { memSensorsConfigEntry 20 }
|
|
|
|
memSensorsHumidityLowThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidity at which the low humidity threshold alarm
|
|
will be generated."
|
|
::= { memSensorsConfigEntry 21 }
|
|
|
|
memSensorsHumidityMinThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidity at which the minimum humidity threshold alarm
|
|
will be generated."
|
|
::= { memSensorsConfigEntry 22 }
|
|
|
|
memSensorsHumidityThreshHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The change in humidity required to cause an active humidity
|
|
alarm to change to the inactive state."
|
|
::= { memSensorsConfigEntry 23 }
|
|
|
|
|
|
-- MEM Input Status Table
|
|
|
|
memInputsStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memInputsStatusTable."
|
|
::= { memInputs 1 }
|
|
|
|
memInputsStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemInputsStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting input status information."
|
|
::= { memInputs 2 }
|
|
|
|
memInputsStatusEntry OBJECT-TYPE
|
|
SYNTAX MemInputsStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memInputsStatusModuleNumber, memInputsStatusInputNumber }
|
|
::= { memInputsStatusTable 1 }
|
|
|
|
MemInputsStatusEntry ::=
|
|
SEQUENCE {
|
|
memInputsStatusModuleNumber INTEGER,
|
|
memInputsStatusInputNumber INTEGER,
|
|
memInputsStatusInputName DisplayString,
|
|
memInputsStatusInputLocation DisplayString,
|
|
memInputsStatusCurrentState INTEGER,
|
|
memInputsStatusCurrentAnalogValue DisplayString,
|
|
memInputsStatusAlarmStatus INTEGER,
|
|
memInputsCommStatus INTEGER
|
|
}
|
|
|
|
memInputsStatusModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the module that the input is attached to."
|
|
::= { memInputsStatusEntry 1 }
|
|
|
|
memInputsStatusInputNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of this input on the module."
|
|
::= { memInputsStatusEntry 2 }
|
|
|
|
memInputsStatusInputName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input name."
|
|
::= { memInputsStatusEntry 3 }
|
|
|
|
memInputsStatusInputLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the input."
|
|
::= { memInputsStatusEntry 4 }
|
|
|
|
memInputsStatusCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inputClosedHighMEM (1),
|
|
inputOpenLowMEM (2),
|
|
inputDisabled (3),
|
|
inputStateNotApplicable (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of the input. This OID will return
|
|
inputStateNotAplicable(4) for analog input types. "
|
|
::= { memInputsStatusEntry 5 }
|
|
|
|
memInputsStatusCurrentAnalogValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current analog value of the input in the units defined
|
|
by the user."
|
|
::= { memInputsStatusEntry 6 }
|
|
|
|
memInputsStatusAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
memNormal(1),
|
|
memWarning(2),
|
|
memCritical(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm status of the input."
|
|
::= { memInputsStatusEntry 7 }
|
|
|
|
memInputsCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notInstalled(1),
|
|
commsOK(2),
|
|
commsLost(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The communications status of the input. This OID is only supported by NBRK0200."
|
|
::= { memInputsStatusEntry 8 }
|
|
|
|
-- MEM Input Config Table
|
|
|
|
memInputsConfigTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memInputsConfigTable."
|
|
::= { memInputs 3 }
|
|
|
|
memInputsConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemInputsConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting input configuration information."
|
|
::= { memInputs 4 }
|
|
|
|
memInputsConfigEntry OBJECT-TYPE
|
|
SYNTAX MemInputsConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memInputsConfigModuleNumber, memInputsConfigInputNumber }
|
|
::= { memInputsConfigTable 1 }
|
|
|
|
MemInputsConfigEntry ::=
|
|
SEQUENCE {
|
|
memInputsConfigModuleNumber INTEGER,
|
|
memInputsConfigInputNumber INTEGER,
|
|
memInputName DisplayString,
|
|
memInputLocation DisplayString,
|
|
memInputType INTEGER,
|
|
memInputAlarmGeneration INTEGER,
|
|
memInputNormalState INTEGER,
|
|
memInputAbnormalSeverity INTEGER,
|
|
memInputNumberCalibrationPoints INTEGER,
|
|
memInputAnalogCalibrationPoint1 DisplayString,
|
|
memInputAnalogCalibrationPoint2 DisplayString,
|
|
memInputAnalogCalibrationPoint3 DisplayString,
|
|
memInputAnalogCalibrationPoint4 DisplayString,
|
|
memInputAnalogCalibrationPoint5 DisplayString,
|
|
memInputAnalogCalibrationPoint1Value DisplayString,
|
|
memInputAnalogCalibrationPoint2Value DisplayString,
|
|
memInputAnalogCalibrationPoint3Value DisplayString,
|
|
memInputAnalogCalibrationPoint4Value DisplayString,
|
|
memInputAnalogCalibrationPoint5Value DisplayString,
|
|
memInputAnalogMeasurementUnits DisplayString,
|
|
memInputAnalogMaxThresh DisplayString,
|
|
memInputAnalogHighThresh DisplayString,
|
|
memInputAnalogLowThresh DisplayString,
|
|
memInputAnalogMinThresh DisplayString,
|
|
memInputAnalogThreshHysteresis DisplayString
|
|
}
|
|
|
|
memInputsConfigModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the module that the input is attached to."
|
|
::= { memInputsConfigEntry 1 }
|
|
|
|
memInputsConfigInputNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of this input on the module."
|
|
::= { memInputsConfigEntry 2 }
|
|
|
|
memInputName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the input."
|
|
::= { memInputsConfigEntry 3 }
|
|
|
|
memInputLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the input."
|
|
::= { memInputsConfigEntry 4 }
|
|
|
|
memInputType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noConnection (1),
|
|
dryContact (2),
|
|
digital (3),
|
|
analogmAmps (4),
|
|
analogVolts (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of input this contact will take."
|
|
::= { memInputsConfigEntry 5 }
|
|
|
|
memInputAlarmGeneration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable alarm generation on this input."
|
|
::= { memInputsConfigEntry 6 }
|
|
|
|
memInputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inputClosedHighMEM (1),
|
|
inputOpenLowMEM (2),
|
|
inputDisabled (3),
|
|
inputStateNotApplicable (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the normal (no alarm) state of the input."
|
|
::= { memInputsConfigEntry 7 }
|
|
|
|
memInputAbnormalSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inputSeverityinformational (1),
|
|
inputSeveritywarning (2),
|
|
inputSeveritysevere (3),
|
|
inputSeverityNotApplicable (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the severity of the event that is associated
|
|
with the abnormal state of the input. This OID will return
|
|
inputSeverityNotApplicable(4) for analog input types. "
|
|
::= { memInputsConfigEntry 8 }
|
|
|
|
memInputNumberCalibrationPoints OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of calibration points that are required for
|
|
this input."
|
|
::= { memInputsConfigEntry 9 }
|
|
|
|
memInputAnalogCalibrationPoint1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The electrical value that the input sensor will measure at the
|
|
first calibration point.
|
|
This OID is relevant only for inputs configured as analog type (ma or V)."
|
|
::= { memInputsConfigEntry 10 }
|
|
|
|
memInputAnalogCalibrationPoint2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The electrical value that the input sensor will measure at the
|
|
second calibration point.
|
|
This OID is relevant only for inputs configured as analog type (ma or V)."
|
|
::= { memInputsConfigEntry 11 }
|
|
|
|
memInputAnalogCalibrationPoint3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The electrical value that the input sensor will measure at the
|
|
third calibration point.
|
|
This OID is relevant only for inputs configured as analog type (ma or V)."
|
|
::= { memInputsConfigEntry 12 }
|
|
|
|
memInputAnalogCalibrationPoint4 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The electrical value that the input sensor will measure at the
|
|
fourth calibration point.
|
|
This OID is relevant only for inputs configured as analog type (ma or V)."
|
|
::= { memInputsConfigEntry 13 }
|
|
|
|
memInputAnalogCalibrationPoint5 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The electrical value that the input sensor will measure at the
|
|
fifth calibration point.
|
|
This OID is relevant only for inputs configured as analog type (ma or V)."
|
|
::= { memInputsConfigEntry 14 }
|
|
|
|
memInputAnalogCalibrationPoint1Value OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the input, in units of measure defined by
|
|
the user, that corresponds to the current setting at the
|
|
first calibration point."
|
|
::= { memInputsConfigEntry 15 }
|
|
|
|
memInputAnalogCalibrationPoint2Value OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the input, in units of measure defined by
|
|
the user, that corresponds to the current setting at the
|
|
second calibration point."
|
|
::= { memInputsConfigEntry 16 }
|
|
|
|
memInputAnalogCalibrationPoint3Value OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the input, in units of measure defined by
|
|
the user, that corresponds to the current setting at the
|
|
third calibration point."
|
|
::= { memInputsConfigEntry 17 }
|
|
|
|
memInputAnalogCalibrationPoint4Value OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the input, in units of measure defined by
|
|
the user, that corresponds to the current setting at the
|
|
fourth calibration point."
|
|
::= { memInputsConfigEntry 18 }
|
|
|
|
memInputAnalogCalibrationPoint5Value OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the input, in units of measure defined by
|
|
the user, that corresponds to the current setting at the
|
|
fifth calibration point."
|
|
::= { memInputsConfigEntry 19 }
|
|
|
|
memInputAnalogMeasurementUnits OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The units of measure to be used for this input."
|
|
::= { memInputsConfigEntry 20 }
|
|
|
|
memInputAnalogMaxThresh OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input value at which a maximum threshold violation
|
|
alarm will be generated on this input."
|
|
::= { memInputsConfigEntry 21 }
|
|
|
|
memInputAnalogHighThresh OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input value at which a high threshold violation
|
|
alarm will be generated on this input."
|
|
::= { memInputsConfigEntry 22 }
|
|
|
|
memInputAnalogLowThresh OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input value at which a low threshold violation
|
|
alarm will be generated on this input."
|
|
::= { memInputsConfigEntry 23 }
|
|
|
|
memInputAnalogMinThresh OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input value at which a minimum threshold violation
|
|
alarm will be generated on this input."
|
|
::= { memInputsConfigEntry 24 }
|
|
|
|
|
|
memInputAnalogThreshHysteresis OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The change in value required to cause an alarm on this input
|
|
to change from active to inactive."
|
|
::= { memInputsConfigEntry 25 }
|
|
|
|
|
|
-- MEM Output Status Table
|
|
|
|
memOutputStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memOutputStatusTable."
|
|
::= { memOutputs 1 }
|
|
|
|
memOutputStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemOutputStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting output status information."
|
|
::= { memOutputs 2 }
|
|
|
|
memOutputStatusEntry OBJECT-TYPE
|
|
SYNTAX MemOutputStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memOutputStatusModuleNumber, memOutputStatusOutputNumber }
|
|
::= { memOutputStatusTable 1 }
|
|
|
|
MemOutputStatusEntry ::=
|
|
SEQUENCE {
|
|
memOutputStatusModuleNumber INTEGER,
|
|
memOutputStatusOutputNumber INTEGER,
|
|
memOutputStatusOutputName DisplayString,
|
|
memOutputStatusOutputLocation DisplayString,
|
|
memOutputStatusCurrentState INTEGER
|
|
}
|
|
|
|
memOutputStatusModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the module that the output is attached to."
|
|
::= { memOutputStatusEntry 1 }
|
|
|
|
memOutputStatusOutputNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of this output on the module."
|
|
::= { memOutputStatusEntry 2 }
|
|
|
|
memOutputStatusOutputName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output name."
|
|
::= { memOutputStatusEntry 3 }
|
|
|
|
memOutputStatusOutputLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the output."
|
|
::= { memOutputStatusEntry 4 }
|
|
|
|
memOutputStatusCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
memOutputClosed (1),
|
|
memOutputOpen (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the output."
|
|
::= { memOutputStatusEntry 5 }
|
|
|
|
|
|
-- MEM Output Config Table
|
|
|
|
memOutputConfigTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memOutputConfigTable."
|
|
::= { memOutputs 3 }
|
|
|
|
memOutputConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemOutputConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting output configuration information."
|
|
::= { memOutputs 4 }
|
|
|
|
memOutputConfigEntry OBJECT-TYPE
|
|
SYNTAX MemOutputConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memOutputConfigModuleNumber, memOutputConfigOutputNumber }
|
|
::= { memOutputConfigTable 1 }
|
|
|
|
MemOutputConfigEntry ::=
|
|
SEQUENCE {
|
|
memOutputConfigModuleNumber INTEGER,
|
|
memOutputConfigOutputNumber INTEGER,
|
|
memOutputName DisplayString,
|
|
memOutputLocation DisplayString,
|
|
memOutputNormalState INTEGER,
|
|
memOutputAction INTEGER
|
|
}
|
|
|
|
memOutputConfigModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the module that the output is attached to."
|
|
::= { memOutputConfigEntry 1 }
|
|
|
|
memOutputConfigOutputNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of this output on the module."
|
|
::= { memOutputConfigEntry 2 }
|
|
|
|
memOutputName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the output."
|
|
::= { memOutputConfigEntry 3 }
|
|
|
|
memOutputLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the output."
|
|
::= { memOutputConfigEntry 4 }
|
|
|
|
memOutputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
memOutputClosed (1),
|
|
memOutputOpen (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the output that will not generate an alarm."
|
|
::= { memOutputConfigEntry 5 }
|
|
|
|
memOutputAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
memActionClose (1),
|
|
memActionOpen (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manual control actions for the output. SNMP get command will return the state
|
|
of the output, SNMP set of this OID controls the output."
|
|
::= { memOutputConfigEntry 6 }
|
|
|
|
|
|
-- MEM Outlet Status Table
|
|
|
|
memOutletStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memOutletStatusTable."
|
|
::= { memOutlets 1 }
|
|
|
|
memOutletStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemOutletStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting outlet status information."
|
|
::= { memOutlets 2 }
|
|
|
|
memOutletStatusEntry OBJECT-TYPE
|
|
SYNTAX MemOutletStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memOutletStatusModuleNumber, memOutletStatusOutletNumber }
|
|
::= { memOutletStatusTable 1 }
|
|
|
|
MemOutletStatusEntry ::=
|
|
SEQUENCE {
|
|
memOutletStatusModuleNumber INTEGER,
|
|
memOutletStatusOutletNumber INTEGER,
|
|
memOutletStatusOutletName DisplayString,
|
|
memOutletStatusOutletLocation DisplayString,
|
|
memOutletStatusCurrentState INTEGER
|
|
}
|
|
|
|
memOutletStatusModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the module that the outlet is attached to."
|
|
::= { memOutletStatusEntry 1 }
|
|
|
|
memOutletStatusOutletNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of this outlet on the module."
|
|
::= { memOutletStatusEntry 2 }
|
|
|
|
memOutletStatusOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet name."
|
|
::= { memOutletStatusEntry 3 }
|
|
|
|
memOutletStatusOutletLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the outlet."
|
|
::= { memOutletStatusEntry 4 }
|
|
|
|
memOutletStatusCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the outlet."
|
|
::= { memOutletStatusEntry 5 }
|
|
|
|
|
|
-- MEM Outlet Config Table
|
|
|
|
memOutletConfigTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memOutletConfigTable."
|
|
::= { memOutlets 3 }
|
|
|
|
memOutletConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting outlet configuration information."
|
|
::= { memOutlets 4 }
|
|
|
|
memOutletConfigEntry OBJECT-TYPE
|
|
SYNTAX MemOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memOutletConfigModuleNumber, memOutletConfigOutletNumber }
|
|
::= { memOutletConfigTable 1 }
|
|
|
|
MemOutletConfigEntry ::=
|
|
SEQUENCE {
|
|
memOutletConfigModuleNumber INTEGER,
|
|
memOutletConfigOutletNumber INTEGER,
|
|
memOutletName DisplayString,
|
|
memOutletLocation DisplayString,
|
|
memOutletNormalState INTEGER,
|
|
memOutletAction INTEGER
|
|
}
|
|
|
|
memOutletConfigModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the module that the Outlet is attached to."
|
|
::= { memOutletConfigEntry 1 }
|
|
|
|
memOutletConfigOutletNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of this Outlet on the module."
|
|
::= { memOutletConfigEntry 2 }
|
|
|
|
memOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the Outlet."
|
|
::= { memOutletConfigEntry 3 }
|
|
|
|
memOutletLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the Outlet."
|
|
::= { memOutletConfigEntry 4 }
|
|
|
|
memOutletNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the Outlet that will not generate an alarm."
|
|
::= { memOutletConfigEntry 5 }
|
|
|
|
memOutletAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turnOff (1),
|
|
turnOn (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manual control actions for the Outlet. Get displays state
|
|
of outlet, set controls outlet."
|
|
::= { memOutletConfigEntry 6 }
|
|
|
|
|
|
-- MEM Beacon Status Table
|
|
|
|
memBeaconStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memBeaconStatusTable."
|
|
::= { memBeacons 1 }
|
|
|
|
memBeaconStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemBeaconStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting beacon status information."
|
|
::= { memBeacons 2 }
|
|
|
|
memBeaconStatusEntry OBJECT-TYPE
|
|
SYNTAX MemBeaconStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memBeaconStatusModuleNumber, memBeaconStatusBeaconNumber }
|
|
::= { memBeaconStatusTable 1 }
|
|
|
|
MemBeaconStatusEntry ::=
|
|
SEQUENCE {
|
|
memBeaconStatusModuleNumber INTEGER,
|
|
memBeaconStatusBeaconNumber INTEGER,
|
|
memBeaconStatusBeaconName DisplayString,
|
|
memBeaconStatusBeaconLocation DisplayString,
|
|
memBeaconStatusCurrentState INTEGER
|
|
}
|
|
|
|
memBeaconStatusModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the module that the beacon is attached to."
|
|
::= { memBeaconStatusEntry 1 }
|
|
|
|
memBeaconStatusBeaconNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of this beacon on the module."
|
|
::= { memBeaconStatusEntry 2 }
|
|
|
|
memBeaconStatusBeaconName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The beacon name."
|
|
::= { memBeaconStatusEntry 3 }
|
|
|
|
memBeaconStatusBeaconLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the beacon."
|
|
::= { memBeaconStatusEntry 4 }
|
|
|
|
memBeaconStatusCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the beacon."
|
|
::= { memBeaconStatusEntry 5 }
|
|
|
|
|
|
-- MEM Beacon Config Table
|
|
|
|
memBeaconConfigTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the memBeaconConfigTable."
|
|
::= { memBeacons 3 }
|
|
|
|
memBeaconConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MemBeaconConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting beacon configuration information."
|
|
::= { memBeacons 4 }
|
|
|
|
memBeaconConfigEntry OBJECT-TYPE
|
|
SYNTAX MemBeaconConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { memBeaconConfigModuleNumber, memBeaconConfigBeaconNumber }
|
|
::= { memBeaconConfigTable 1 }
|
|
|
|
MemBeaconConfigEntry ::=
|
|
SEQUENCE {
|
|
memBeaconConfigModuleNumber INTEGER,
|
|
memBeaconConfigBeaconNumber INTEGER,
|
|
memBeaconConfigName DisplayString,
|
|
memBeaconConfigLocation DisplayString,
|
|
memBeaconAction INTEGER
|
|
}
|
|
|
|
memBeaconConfigModuleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the module that the beacon is attached to."
|
|
::= { memBeaconConfigEntry 1 }
|
|
|
|
memBeaconConfigBeaconNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of this beacon on the module."
|
|
::= { memBeaconConfigEntry 2 }
|
|
|
|
memBeaconConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the beacon."
|
|
::= { memBeaconConfigEntry 3 }
|
|
|
|
memBeaconConfigLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the beacon."
|
|
::= { memBeaconConfigEntry 4 }
|
|
|
|
memBeaconAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turnOff (1),
|
|
turnOn (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control action (on/off) for the beacon. Setting this OID will turn the
|
|
beacon on/off. Getting this OID will respond with the current state."
|
|
::= { memBeaconConfigEntry 5 }
|
|
|
|
|
|
-- Integrated Environmental Monitor (IEM)
|
|
|
|
iemIdentHardwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Integrated Environmental
|
|
Monitor."
|
|
::= { iemIdent 1 }
|
|
|
|
iemConfigProbesNumProbes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of temperature and humidity probes available."
|
|
::= { iemConfig 1 }
|
|
|
|
iemConfigProbesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IemConfigProbesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of probes supported by the Environmental Monitor
|
|
and their configurations."
|
|
::= { iemConfig 2 }
|
|
|
|
iemConfigProbesEntry OBJECT-TYPE
|
|
SYNTAX IemConfigProbesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Environmental Monitor probe configurations."
|
|
INDEX { iemConfigProbeNumber }
|
|
::= { iemConfigProbesTable 1 }
|
|
|
|
IemConfigProbesEntry ::=
|
|
SEQUENCE {
|
|
iemConfigProbeNumber
|
|
INTEGER,
|
|
iemConfigProbeName
|
|
DisplayString,
|
|
iemConfigProbeHighTempThreshold
|
|
INTEGER,
|
|
iemConfigProbeLowTempThreshold
|
|
INTEGER,
|
|
iemConfigProbeTempUnits
|
|
INTEGER,
|
|
iemConfigProbeHighHumidThreshold
|
|
INTEGER,
|
|
iemConfigProbeLowHumidThreshold
|
|
INTEGER,
|
|
iemConfigProbeHighTempEnable
|
|
INTEGER,
|
|
iemConfigProbeLowTempEnable
|
|
INTEGER,
|
|
iemConfigProbeHighHumidEnable
|
|
INTEGER,
|
|
iemConfigProbeLowHumidEnable
|
|
INTEGER,
|
|
iemConfigProbeMaxTempThreshold
|
|
INTEGER,
|
|
iemConfigProbeMinTempThreshold
|
|
INTEGER,
|
|
iemConfigProbeMaxHumidThreshold
|
|
INTEGER,
|
|
iemConfigProbeMinHumidThreshold
|
|
INTEGER,
|
|
iemConfigProbeMaxTempEnable
|
|
INTEGER,
|
|
iemConfigProbeMinTempEnable
|
|
INTEGER,
|
|
iemConfigProbeMaxHumidEnable
|
|
INTEGER,
|
|
iemConfigProbeMinHumidEnable
|
|
INTEGER,
|
|
iemConfigProbeTempHysteresis
|
|
INTEGER,
|
|
iemConfigProbeHumidHysteresis
|
|
INTEGER,
|
|
iemConfigProbeLocation
|
|
DisplayString
|
|
}
|
|
|
|
iemConfigProbeNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to a Environmental Monitor probe entry."
|
|
::= { iemConfigProbesEntry 1 }
|
|
|
|
iemConfigProbeName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for the probe set by the user,
|
|
possibly denoting its location or purpose."
|
|
::= { iemConfigProbesEntry 2 }
|
|
|
|
iemConfigProbeHighTempThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature alarm threshold for the probe.
|
|
Units are displayed in the scale selected in the
|
|
'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { iemConfigProbesEntry 3 }
|
|
|
|
iemConfigProbeLowTempThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature alarm threshold for the probe.
|
|
Units are displayed in the scale selected in the
|
|
'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { iemConfigProbesEntry 4 }
|
|
|
|
iemConfigProbeTempUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
celsius(1),
|
|
fahrenheit(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature scale used to display the temperature
|
|
thresholds of the probe, Celsius(1) or Fahrenheit(2).
|
|
This setting is based on the system preferences
|
|
configuration in the agent."
|
|
::= { iemConfigProbesEntry 5 }
|
|
|
|
iemConfigProbeHighHumidThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high humidity alarm threshold for the probe in
|
|
percent relative humidity."
|
|
::= { iemConfigProbesEntry 6 }
|
|
|
|
iemConfigProbeLowHumidThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low humidity alarm threshold for the probe in
|
|
percent relative humidity."
|
|
::= { iemConfigProbesEntry 7 }
|
|
|
|
iemConfigProbeHighTempEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { iemConfigProbesEntry 8 }
|
|
|
|
iemConfigProbeLowTempEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { iemConfigProbesEntry 9 }
|
|
|
|
iemConfigProbeHighHumidEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high humidity alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { iemConfigProbesEntry 10 }
|
|
|
|
iemConfigProbeLowHumidEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low humidity alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { iemConfigProbesEntry 11 }
|
|
|
|
iemConfigProbeMaxTempThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximun temperature alarm threshold for the probe.
|
|
Units are displayed in the scale selected in the
|
|
'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { iemConfigProbesEntry 12 }
|
|
|
|
iemConfigProbeMinTempThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimun temperature alarm threshold for the probe.
|
|
Units are displayed in the scale selected in the
|
|
'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { iemConfigProbesEntry 13 }
|
|
|
|
iemConfigProbeMaxHumidThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum humidity alarm threshold for the probe in
|
|
percent relative humidity."
|
|
::= { iemConfigProbesEntry 14 }
|
|
|
|
iemConfigProbeMinHumidThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum humidity alarm threshold for the probe in
|
|
percent relative humidity."
|
|
::= { iemConfigProbesEntry 15 }
|
|
|
|
iemConfigProbeMaxTempEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum temperature alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { iemConfigProbesEntry 16 }
|
|
|
|
iemConfigProbeMinTempEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { iemConfigProbesEntry 17 }
|
|
|
|
iemConfigProbeMaxHumidEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum humidity alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { iemConfigProbesEntry 18 }
|
|
|
|
iemConfigProbeMinHumidEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum humidity alarm enable/disable for the
|
|
probe. No alarm will be generated if this value
|
|
is set to disabled(1). The alarm will be
|
|
generated if this value is set to enabled(2) and
|
|
the threshold has been violated."
|
|
::= { iemConfigProbesEntry 19 }
|
|
|
|
iemConfigProbeTempHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees beyond the temperature thresholds
|
|
at which an active temperature alarm will be cleared.
|
|
This configuration setting applies to all temperature
|
|
thresholds.
|
|
Units are displayed in the scale selected in
|
|
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { iemConfigProbesEntry 20 }
|
|
|
|
iemConfigProbeHumidHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of percent RH points beyond the humidity
|
|
thresholds at which an active humidity alarm will be
|
|
cleared. This configuration setting applies to all
|
|
humidity thresholds.
|
|
Units are displayed in the scale selected in
|
|
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
|
|
::= { iemConfigProbesEntry 21 }
|
|
|
|
iemConfigProbeLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string describing the location of the probe."
|
|
::= { iemConfigProbesEntry 22 }
|
|
|
|
iemConfigContactsNumContacts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of contacts available on the Environmental
|
|
Monitor."
|
|
::= { iemConfig 3 }
|
|
|
|
iemConfigContactsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IemConfigContactsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of contacts supported by the Environmental Monitor
|
|
and their configurations."
|
|
::= { iemConfig 4 }
|
|
|
|
iemConfigContactsEntry OBJECT-TYPE
|
|
SYNTAX IemConfigContactsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Environmental Monitor contact configurations."
|
|
INDEX { iemConfigContactNumber }
|
|
::= { iemConfigContactsTable 1 }
|
|
|
|
IemConfigContactsEntry ::=
|
|
SEQUENCE {
|
|
iemConfigContactNumber
|
|
INTEGER,
|
|
iemConfigContactName
|
|
DisplayString,
|
|
iemConfigContactEnable
|
|
INTEGER,
|
|
iemConfigContactSeverity
|
|
INTEGER,
|
|
iemConfigContactNormalState
|
|
INTEGER,
|
|
iemConfigContactLocation
|
|
DisplayString
|
|
}
|
|
|
|
iemConfigContactNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of an Environmental Monitor contact."
|
|
::= { iemConfigContactsEntry 1 }
|
|
|
|
iemConfigContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for the Environmental Monitor contact
|
|
set by the user, possibly denoting its location or purpose."
|
|
::= { iemConfigContactsEntry 2 }
|
|
|
|
iemConfigContactEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An Environmental Monitor contact alarm enable/disable."
|
|
::= { iemConfigContactsEntry 3 }
|
|
|
|
iemConfigContactSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical(1),
|
|
warning(2),
|
|
informational(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The severtity of the alarm that will be triggered when
|
|
the input contact is activated. The alarms can be
|
|
critical(1), warning(2) or informational(3).
|
|
NOTE: informational(3) is deprecated (and no longer valid) for this OID."
|
|
::= { iemConfigContactsEntry 4 }
|
|
|
|
iemConfigContactNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open(1),
|
|
closed(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The contact state that will be considered normal, i.e.
|
|
will not trigger an alarm. The states are open(1) or
|
|
closed(2)."
|
|
::= { iemConfigContactsEntry 5 }
|
|
|
|
iemConfigContactLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive label for the contact denoting its
|
|
location or purpose."
|
|
::= { iemConfigContactsEntry 6 }
|
|
|
|
iemConfigConfigRelaysNumRelays OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output relays supported by the Environmental
|
|
Monitor."
|
|
::= { iemConfig 5 }
|
|
|
|
|
|
iemConfigRelaysTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IemConfigRelaysEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output relays supported by the Environmental Monitor
|
|
and their configurations."
|
|
::= { iemConfig 6 }
|
|
|
|
iemConfigRelaysEntry OBJECT-TYPE
|
|
SYNTAX IemConfigRelaysEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Environmental Monitor output relay configurations."
|
|
INDEX { iemConfigRelayNumber }
|
|
::= { iemConfigRelaysTable 1 }
|
|
|
|
IemConfigRelaysEntry ::=
|
|
SEQUENCE {
|
|
iemConfigRelayNumber
|
|
INTEGER,
|
|
iemConfigRelayName
|
|
DisplayString,
|
|
iemConfigRelayNormalState
|
|
INTEGER,
|
|
iemConfigRelayFaultCondition
|
|
INTEGER
|
|
}
|
|
|
|
iemConfigRelayNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of an Environmental Monitor output relay."
|
|
::= { iemConfigRelaysEntry 1 }
|
|
|
|
iemConfigRelayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name of an Environmental Monitor output relay,
|
|
set by the user, describing its location or purpose."
|
|
::= { iemConfigRelaysEntry 2 }
|
|
|
|
iemConfigRelayNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open(1),
|
|
closed(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state (non-fault state) of an Environmental
|
|
Monitor output relay, either open(1) or closed(2)."
|
|
::= { iemConfigRelaysEntry 3 }
|
|
|
|
iemConfigRelayFaultCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fault condition used to activate the output relay."
|
|
::= { iemConfigRelaysEntry 4 }
|
|
|
|
iemStatusProbesNumProbes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of available probes on the Environmental
|
|
Monitor."
|
|
::= { iemStatus 1 }
|
|
|
|
iemStatusProbesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IemStatusProbesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of probes supported by the Environmental Monitor
|
|
and their status."
|
|
::= { iemStatus 2 }
|
|
|
|
iemStatusProbesEntry OBJECT-TYPE
|
|
SYNTAX IemStatusProbesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the probe."
|
|
INDEX { iemStatusProbeNumber }
|
|
::= { iemStatusProbesTable 1 }
|
|
|
|
IemStatusProbesEntry ::=
|
|
SEQUENCE {
|
|
iemStatusProbeNumber
|
|
INTEGER,
|
|
iemStatusProbeName
|
|
DisplayString,
|
|
iemStatusProbeStatus
|
|
INTEGER,
|
|
iemStatusProbeCurrentTemp
|
|
INTEGER,
|
|
iemStatusProbeTempUnits
|
|
INTEGER,
|
|
iemStatusProbeCurrentHumid
|
|
INTEGER,
|
|
iemStatusProbeHighTempViolation
|
|
INTEGER,
|
|
iemStatusProbeLowTempViolation
|
|
INTEGER,
|
|
iemStatusProbeHighHumidViolation
|
|
INTEGER,
|
|
iemStatusProbeLowHumidViolation
|
|
INTEGER,
|
|
iemStatusProbeMaxTempViolation
|
|
INTEGER,
|
|
iemStatusProbeMinTempViolation
|
|
INTEGER,
|
|
iemStatusProbeMaxHumidViolation
|
|
INTEGER,
|
|
iemStatusProbeMinHumidViolation
|
|
INTEGER,
|
|
iemStatusProbeLocation
|
|
DisplayString
|
|
}
|
|
|
|
iemStatusProbeNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the probe."
|
|
::= { iemStatusProbesEntry 1 }
|
|
|
|
iemStatusProbeName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for the probe set by the user."
|
|
::= { iemStatusProbesEntry 2 }
|
|
|
|
iemStatusProbeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disconnected(1),
|
|
connected(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The connected status of the probe, either
|
|
disconnected(1) or connected(2)."
|
|
::= { iemStatusProbesEntry 3 }
|
|
|
|
iemStatusProbeCurrentTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current temperature reading from the probe displayed
|
|
in the units shown in the 'iemStatusProbeTempUnits' OID
|
|
(Celsius or Fahrenheit)."
|
|
::= { iemStatusProbesEntry 4 }
|
|
|
|
iemStatusProbeTempUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
celsius(1),
|
|
fahrenheit(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature scale used to display the temperature
|
|
thresholds of the probe, Celsius(1) or Fahrenheit(2).
|
|
This setting is based on the system preferences
|
|
configuration in the agent."
|
|
::= { iemStatusProbesEntry 5 }
|
|
|
|
iemStatusProbeCurrentHumid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current humidity reading from the probe in percent
|
|
relative humidity."
|
|
::= { iemStatusProbesEntry 6 }
|
|
|
|
iemStatusProbeHighTempViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
highTempViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature violation status of the probe
|
|
temperature reading. This OID will show a highTempViolation(2)
|
|
if the current temperature reading shown in the
|
|
'iemStatusProbeCurrentTemp' OID is greater than or equal to
|
|
the high temperature threshold value, the
|
|
'iemConfigProbeHighTempThreshold' OID, and the value of the
|
|
'iemConfigProbeHighTempEnable' OID is enabled. Otherwise it will show
|
|
noViolation(1). If the 'iemConfigProbeHighTempEnable' OID is disabled,
|
|
this OID will show disabled(3)."
|
|
::= { iemStatusProbesEntry 7 }
|
|
|
|
iemStatusProbeLowTempViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
lowTempViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature violation status of the probe
|
|
temperature reading. This OID will show a lowTempViolation(2)
|
|
if the current temperature reading shown in the
|
|
'iemStatusProbeCurrentTemp' OID is less than or equal to
|
|
the low temperature threshold value, the
|
|
'iemConfigProbeLowTempThreshold' OID, and the value of the
|
|
'iemPConfigrobeLowTempEnable' OID is enabled. Otherwise it will show
|
|
noViolation(1). If the 'iemConfigProbeLowTempEnable' OID is disabled,
|
|
this OID will show disabled(3)."
|
|
::= { iemStatusProbesEntry 8 }
|
|
|
|
iemStatusProbeHighHumidViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
highHumidViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high humidity violation status of the probe humidity
|
|
reading. This OID will show a highTempViolation(2)
|
|
if the current humidity reading shown in the
|
|
'iemStatusProbeCurrentHumid' OID is greater than or equal to
|
|
the high humidity threshold value, the
|
|
'iemConfigProbeHighHumidThreshold' OID, and the value of the
|
|
'iemConfigProbeHighHumidEnable' OID is enabled. Otherwise it will
|
|
show noViolation(1). If the 'iemConfigProbeHighHumidEnable' OID is
|
|
disabled, this OID will show disabled(3)."
|
|
::= { iemStatusProbesEntry 9 }
|
|
|
|
iemStatusProbeLowHumidViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
lowHumidViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low humidity violation status of the probe humidity
|
|
reading. This OID will show a lowTempViolation(2)
|
|
if the current humidity reading shown in the
|
|
'iemStatusProbeCurrentHumid' OID is less than or equal to
|
|
the low humidity threshold value, the
|
|
'iemConfigProbeLowHumidThreshold' OID, and the value of the
|
|
'iemConfigProbeLowHumidEnable' OID is enabled. Otherwise it will
|
|
show noViolation(1). If the 'iemConfigProbeLowHumidEnable' OID is
|
|
disabled, this OID will show disabled(3)."
|
|
::= { iemStatusProbesEntry 10 }
|
|
|
|
iemStatusProbeMaxTempViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
maxTempViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The max temperature violation status of the probe
|
|
temperature reading. This OID will show a maxTempViolation(2)
|
|
if the current temperature reading shown in the
|
|
'iemStatusProbeCurrentTemp' OID is greater than or equal to
|
|
the maximun temperature threshold value, the
|
|
'iemConfigProbeMaxTempThreshold' OID, and the value of the
|
|
'iemConfigProbeMaxTempEnable' OID is enabled. Otherwise it will show
|
|
noViolation(1). If the 'iemConfigProbeMaxTempEnable' OID is disabled,
|
|
this OID will show disabled(3)."
|
|
::= { iemStatusProbesEntry 11 }
|
|
|
|
iemStatusProbeMinTempViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
minTempViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum temperature violation status of the probe
|
|
temperature reading. This OID will show a minTempViolation(2)
|
|
if the current temperature reading shown in the
|
|
'iemStatusProbeCurrentTemp' OID is less than or equal to
|
|
the minimum temperature threshold value, the
|
|
'iemConfigProbeMinTempThreshold' OID, and the value of the
|
|
'iemConfigProbeMinTempEnable' OID is enabled. Otherwise it will show
|
|
noViolation(1). If the 'iemConfigProbeMinTempEnable' OID is disabled,
|
|
this OID will show disabled(3)."
|
|
::= { iemStatusProbesEntry 12 }
|
|
|
|
iemStatusProbeMaxHumidViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
maxHumidViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum humidity violation status of the probe humidity
|
|
reading. This OID will show a maxTempViolation(2)
|
|
if the current humidity reading shown in the
|
|
'iemStatusProbeCurrentHumid' OID is greater than or equal to
|
|
the maximum humidity threshold value, the
|
|
'iemConfigProbeMaxHumidThreshold' OID, and the value of the
|
|
'iemConfigProbeMaxHumidEnable' OID is enabled. Otherwise it will
|
|
show noViolation(1). If the 'iemConfigProbeMaxHumidEnable' OID is
|
|
disabled, this OID will show disabled(3)"
|
|
::= { iemStatusProbesEntry 13 }
|
|
|
|
iemStatusProbeMinHumidViolation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noViolation(1),
|
|
minHumidViolation(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum humidity violation status of the probe humidity
|
|
reading. This OID will show a minTempViolation(2)
|
|
if the current humidity reading shown in the
|
|
'iemStatusProbeCurrentHumid' OID is less than or equal to
|
|
the minimum humidity threshold value, the
|
|
'iemConfigProbeMinHumidThreshold' OID, and the value of the
|
|
'iemConfigProbeMinHumidEnable' OID is enabled. Otherwise it will
|
|
show noViolation(1). If the 'iemConfigProbeMinHumidEnable' OID is
|
|
disabled, this OID will show disabled(3)."
|
|
::= { iemStatusProbesEntry 14 }
|
|
|
|
iemStatusProbeLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive location for the probe set by the user."
|
|
::= { iemStatusProbesEntry 15 }
|
|
|
|
iemStatusContactsNumContacts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of contacts supported on the
|
|
Environmental Monitor."
|
|
::= { iemStatus 3 }
|
|
|
|
iemStatusContactsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IemStatusContactsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of contacts supported by the Environmental Monitor
|
|
and their status."
|
|
::= { iemStatus 4 }
|
|
|
|
iemStatusContactsEntry OBJECT-TYPE
|
|
SYNTAX IemStatusContactsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the contact."
|
|
INDEX { iemStatusContactNumber }
|
|
::= { iemStatusContactsTable 1 }
|
|
|
|
IemStatusContactsEntry ::=
|
|
SEQUENCE {
|
|
iemStatusContactNumber
|
|
INTEGER,
|
|
iemStatusContactName
|
|
DisplayString,
|
|
iemStatusContactStatus
|
|
INTEGER
|
|
}
|
|
|
|
iemStatusContactNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the Environmental Monitor contact."
|
|
::= { iemStatusContactsEntry 1 }
|
|
|
|
iemStatusContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for the Environmental Monitor contact
|
|
set by the user, denoting its location or purpose."
|
|
::= { iemStatusContactsEntry 2 }
|
|
|
|
iemStatusContactStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noFault(1),
|
|
fault(2),
|
|
disabled(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the Environmental Monitor contact. The status
|
|
will show noFault(1) if the contact is in the normal state
|
|
and the 'iemConfigContactEnable' OID is enabled. The status will
|
|
show a fault(2) if the contact is faulted and the
|
|
'iemConfigContactEnable' OID is enabled. If the
|
|
'iemConfigContactEnable' OID is disabled, the status will show
|
|
disabled(3)."
|
|
::= { iemStatusContactsEntry 3 }
|
|
|
|
iemStatusRelaysNumRelays OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output relays supported on the
|
|
Environmental Monitor."
|
|
::= { iemStatus 6 }
|
|
|
|
iemStatusRelaysTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IemStatusRelaysEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of output relays supported by the
|
|
Environmental Monitor and their status."
|
|
::= { iemStatus 7 }
|
|
|
|
iemStatusRelaysEntry OBJECT-TYPE
|
|
SYNTAX IemStatusRelaysEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the relay."
|
|
INDEX { iemStatusRelayNumber }
|
|
::= { iemStatusRelaysTable 1 }
|
|
|
|
IemStatusRelaysEntry ::=
|
|
SEQUENCE {
|
|
iemStatusRelayNumber
|
|
INTEGER,
|
|
iemStatusRelayName
|
|
DisplayString,
|
|
iemStatusRelayStatus
|
|
INTEGER
|
|
}
|
|
|
|
iemStatusRelayNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the output relay."
|
|
::= { iemStatusRelaysEntry 1 }
|
|
|
|
iemStatusRelayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for the output relay set by the
|
|
user, denoting its location or purpose."
|
|
::= { iemStatusRelaysEntry 2 }
|
|
|
|
iemStatusRelayStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
faultState(1),
|
|
normalState(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the output relay, either faultState(1) or
|
|
normalState(2)."
|
|
::= { iemStatusRelaysEntry 3 }
|
|
|
|
-- Environmental Management System (EMS)
|
|
|
|
-- EMS IDENT
|
|
|
|
emsIdentEMSName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
device. "
|
|
::= { emsIdent 1 }
|
|
|
|
emsIdentProductNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the model number of
|
|
the device. This value is set at the factory."
|
|
::= { emsIdent 2 }
|
|
|
|
emsIdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the device."
|
|
::= { emsIdent 3 }
|
|
|
|
emsIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the device.
|
|
This value is set at the factory."
|
|
::= { emsIdent 4 }
|
|
|
|
emsIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the device was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory. "
|
|
::= { emsIdent 5 }
|
|
|
|
emsIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the serial number of
|
|
the device. This value is set at the factory."
|
|
::= { emsIdent 6 }
|
|
|
|
-- EMS CONTROL
|
|
|
|
-- EMS OUTPUT RELAY CONTROL STATUS TABLE
|
|
|
|
emsOutputRelayControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EmsOutputRelayControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of individual output relays. The number of
|
|
entries is contained in the emsStatusOutputRelayCount OID."
|
|
::= { emsOutputRelayControl 1 }
|
|
|
|
emsOutputRelayControlEntry OBJECT-TYPE
|
|
SYNTAX EmsOutputRelayControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output relays to control."
|
|
INDEX { emsOutputRelayControlOutputRelayIndex }
|
|
::= { emsOutputRelayControlTable 1 }
|
|
|
|
EmsOutputRelayControlEntry ::=
|
|
SEQUENCE {
|
|
emsOutputRelayControlOutputRelayIndex INTEGER,
|
|
emsOutputRelayControlOutputRelayName DisplayString,
|
|
emsOutputRelayControlOutputRelayCommand INTEGER
|
|
}
|
|
|
|
emsOutputRelayControlOutputRelayIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the output relay entry."
|
|
::= { emsOutputRelayControlEntry 1 }
|
|
|
|
emsOutputRelayControlOutputRelayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the output relay.
|
|
This OID is provided for informational purposes only."
|
|
::= { emsOutputRelayControlEntry 2 }
|
|
|
|
emsOutputRelayControlOutputRelayCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
immediateCloseEMS (1),
|
|
immediateOpenEMS (2)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the output relay state. If
|
|
the output relay is closed, the immediateCloseEMS (1) value will be returned.
|
|
If the output relay is open, the immediateOpenEMS (2) value will be
|
|
returned.
|
|
|
|
Setting this variable to immediateCloseEMS (1) will immediately close the relay.
|
|
|
|
Setting this variable to immediateOpenEMS (2) will immediately open the relay."
|
|
::= { emsOutputRelayControlEntry 3 }
|
|
|
|
-- EMS OUTLET CONTROL TABLE
|
|
|
|
emsOutletControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EmsOutletControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of individual outlet switches. The number of
|
|
entries is contained in the emsStatusOutletCount OID."
|
|
::= { emsOutletControl 1 }
|
|
|
|
emsOutletControlEntry OBJECT-TYPE
|
|
SYNTAX EmsOutletControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to control."
|
|
INDEX { emsOutletControlOutletIndex }
|
|
::= { emsOutletControlTable 1 }
|
|
|
|
EmsOutletControlEntry ::=
|
|
SEQUENCE {
|
|
emsOutletControlOutletIndex INTEGER,
|
|
emsOutletControlOutletName DisplayString,
|
|
emsOutletControlOutletCommand INTEGER
|
|
}
|
|
|
|
emsOutletControlOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { emsOutletControlEntry 1 }
|
|
|
|
emsOutletControlOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet.
|
|
This OID is provided for informational purposes only."
|
|
::= { emsOutletControlEntry 2 }
|
|
|
|
emsOutletControlOutletCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
immediateOnEMS (1),
|
|
immediateOffEMS (2)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the immediateOnEMS (1) value will be returned.
|
|
If the outlet is off, the immediateOffEMS (2) value will be
|
|
returned.
|
|
|
|
Setting this variable to immediateOnEMS (1) will immediately turn the outlet on.
|
|
|
|
Setting this variable to immediateOffEMS (2) will immediately turn the outlet off."
|
|
::= { emsOutletControlEntry 3 }
|
|
|
|
-- EMS SENSOR CONTROL TABLE
|
|
|
|
emsSensorControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSSensorControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control/reset of individual sensors. The number of
|
|
entries is contained in the emsStatusSensorCount OID."
|
|
::= { emsSensorControl 1 }
|
|
|
|
emsSensorControlEntry OBJECT-TYPE
|
|
SYNTAX EMSSensorControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensors to control/reset."
|
|
INDEX { emsSensorControlSensorIndex }
|
|
::= { emsSensorControlTable 1 }
|
|
|
|
EMSSensorControlEntry ::=
|
|
SEQUENCE {
|
|
emsSensorControlSensorIndex INTEGER,
|
|
emsSensorControlSensorSystemName DisplayString,
|
|
emsSensorControlSensorUserName DisplayString,
|
|
emsSensorControlSensorCommand INTEGER
|
|
}
|
|
|
|
emsSensorControlSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the sensor entry."
|
|
::= { emsSensorControlEntry 1 }
|
|
|
|
emsSensorControlSensorSystemName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system name of the sensor. This describes the hardware system
|
|
intent of this sensor."
|
|
::= { emsSensorControlEntry 2 }
|
|
|
|
emsSensorControlSensorUserName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the sensor as given by the system user."
|
|
::= { emsSensorControlEntry 3 }
|
|
|
|
emsSensorControlSensorCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noCommandEMS (1),
|
|
resetCommandEMS (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return noCommandEMS(1).
|
|
|
|
Setting this variable to resetCommandEMS(2) will issue a reset command to the
|
|
sensor. Some sensors cannot be manually reset and will not be affected
|
|
by this command."
|
|
::= { emsSensorControlEntry 4 }
|
|
|
|
-- EMS ALARM DEVICE CONTROL TABLE
|
|
|
|
emsAlarmDeviceControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EmsAlarmDeviceControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of individual alarm devices.
|
|
Note: Some alarm devices are not controllable. The number of
|
|
entries is contained in the emsStatusAlarmDeviceCount OID."
|
|
::= { emsAlarmDeviceControl 1 }
|
|
|
|
emsAlarmDeviceControlEntry OBJECT-TYPE
|
|
SYNTAX EmsAlarmDeviceControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm devices to control."
|
|
INDEX { emsAlarmDeviceControlDeviceIndex }
|
|
::= { emsAlarmDeviceControlTable 1 }
|
|
|
|
EmsAlarmDeviceControlEntry ::=
|
|
SEQUENCE {
|
|
emsAlarmDeviceControlDeviceIndex INTEGER,
|
|
emsAlarmDeviceControlDeviceName DisplayString,
|
|
emsAlarmDeviceControlDeviceCommand INTEGER
|
|
}
|
|
|
|
emsAlarmDeviceControlDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the alarm device entry."
|
|
::= { emsAlarmDeviceControlEntry 1 }
|
|
|
|
emsAlarmDeviceControlDeviceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the alarm device.
|
|
This OID is provided for informational purposes only."
|
|
::= { emsAlarmDeviceControlEntry 2 }
|
|
|
|
emsAlarmDeviceControlDeviceCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmDeviceOnEMS (1),
|
|
alarmDeviceOffEMS (2),
|
|
alarmDeviceNotInstalledEMS (3)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the device state. If
|
|
the device is active, the alarmDeviceOnEMS (1) value will be returned.
|
|
If the device is inactive, the alarmDeviceOffEMS (2) value will be
|
|
returned. If the device is not installed, the
|
|
alarmDeviceNotInstalledEMS (3) value will be returned.
|
|
|
|
Actions resulting from setting this variable are device-dependent.
|
|
|
|
Setting this variable to alarmDeviceOnEMS (1) will turn that device (ex. Beacon) on.
|
|
Setting this variable to alarmDeviceOffEMS (2) will turn that device off."
|
|
|
|
::= { emsAlarmDeviceControlEntry 3 }
|
|
|
|
|
|
-- EMS CONFIG
|
|
|
|
emsConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the device."
|
|
::= { emsConfig 1 }
|
|
|
|
emsConfigCheckLogLight OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lightDisabled (1),
|
|
lightOnInformational (2),
|
|
lightOnWarning (3),
|
|
lightOnSevere (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The setting of this OID determines the level of event that will
|
|
trigger the check-log light on the EMS. This is not available on the EMU2.
|
|
|
|
lightDisabled (1) disables the check-log light.
|
|
lightOnInformational (2) lights check-log for any event of
|
|
informational severity or above.
|
|
lightOnWarning (3) lights check-log for any event of
|
|
warning severity or above.
|
|
lightOnSevere (4) lights check-log for any event of severe severity."
|
|
|
|
::= { emsConfig 2 }
|
|
|
|
-- EMS PROBE CONFIG TABLE
|
|
|
|
emsProbeConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSProbeConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual probes. The number of
|
|
entries is contained in the emsStatusProbeCount OID."
|
|
::= { emsProbeConfig 1 }
|
|
|
|
emsProbeConfigEntry OBJECT-TYPE
|
|
SYNTAX EMSProbeConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The probes to configure."
|
|
INDEX { emsProbeConfigProbeIndex }
|
|
::= { emsProbeConfigTable 1 }
|
|
|
|
EMSProbeConfigEntry ::=
|
|
SEQUENCE {
|
|
emsProbeConfigProbeIndex INTEGER,
|
|
emsProbeConfigProbeName DisplayString,
|
|
emsProbeConfigProbeHighTempThresh INTEGER,
|
|
emsProbeConfigProbeLowTempThresh INTEGER,
|
|
emsProbeConfigProbeHighHumidityThresh INTEGER,
|
|
emsProbeConfigProbeLowHumidityThresh INTEGER,
|
|
emsProbeConfigProbeMaxTempThresh INTEGER,
|
|
emsProbeConfigProbeMinTempThresh INTEGER,
|
|
emsProbeConfigProbeDeltaTemp INTEGER,
|
|
emsProbeConfigProbeMaxHumidityThresh INTEGER,
|
|
emsProbeConfigProbeMinHumidityThresh INTEGER,
|
|
emsProbeConfigProbeDeltaHumidity INTEGER,
|
|
emsProbeConfigProbeSTIncTempVariance INTEGER,
|
|
emsProbeConfigProbeSTIncTempTime INTEGER,
|
|
emsProbeConfigProbeSTDecTempVariance INTEGER,
|
|
emsProbeConfigProbeSTDecTempTime INTEGER,
|
|
emsProbeConfigProbeLTIncTempVariance INTEGER,
|
|
emsProbeConfigProbeLTIncTempTime INTEGER,
|
|
emsProbeConfigProbeLTDecTempVariance INTEGER,
|
|
emsProbeConfigProbeLTDecTempTime INTEGER
|
|
}
|
|
|
|
emsProbeConfigProbeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the probe entry."
|
|
::= { emsProbeConfigEntry 1 }
|
|
|
|
emsProbeConfigProbeName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the probe."
|
|
::= { emsProbeConfigEntry 2 }
|
|
|
|
emsProbeConfigProbeHighTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe high temperature threshold.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeConfigEntry 3 }
|
|
|
|
emsProbeConfigProbeLowTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe low temperature threshold.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeConfigEntry 4 }
|
|
|
|
emsProbeConfigProbeHighHumidityThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe high humidity threshold.
|
|
|
|
Values are represented in whole number percentage."
|
|
::= { emsProbeConfigEntry 5 }
|
|
|
|
emsProbeConfigProbeLowHumidityThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe low humidity threshold.
|
|
|
|
Values are represented in whole number percentage."
|
|
::= { emsProbeConfigEntry 6 }
|
|
|
|
emsProbeConfigProbeMaxTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe maximum temperature threshold.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeConfigEntry 7 }
|
|
|
|
emsProbeConfigProbeMinTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe minimum temperature threshold.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeConfigEntry 8 }
|
|
|
|
emsProbeConfigProbeDeltaTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe delta temperature.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeConfigEntry 9 }
|
|
|
|
emsProbeConfigProbeMaxHumidityThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe maximum humidity threshold.
|
|
|
|
Values are represented in whole number percentage."
|
|
::= { emsProbeConfigEntry 10 }
|
|
|
|
emsProbeConfigProbeMinHumidityThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe minimum humidity threshold.
|
|
|
|
Values are represented in whole number percentage."
|
|
::= { emsProbeConfigEntry 11 }
|
|
|
|
emsProbeConfigProbeDeltaHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe delta humidity.
|
|
|
|
Values are represented in whole number percentage."
|
|
::= { emsProbeConfigEntry 12 }
|
|
|
|
emsProbeConfigProbeSTIncTempVariance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe short-term increasing temperature variance used for rate of change alarms.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeConfigEntry 13 }
|
|
|
|
emsProbeConfigProbeSTIncTempTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe short-term increasing temperature time used for rate of change alarms.
|
|
|
|
Values are represented in whole number minutes."
|
|
::= { emsProbeConfigEntry 14 }
|
|
|
|
emsProbeConfigProbeSTDecTempVariance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe short-term decreasing temperature variance used for rate of change alarms.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeConfigEntry 15 }
|
|
|
|
emsProbeConfigProbeSTDecTempTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe short-term decreasing temperature time used for rate of change alarms.
|
|
|
|
Values are represented in whole number minutes."
|
|
::= { emsProbeConfigEntry 16 }
|
|
|
|
emsProbeConfigProbeLTIncTempVariance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe long-term increasing temperature variance used for rate of change alarms.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeConfigEntry 17 }
|
|
|
|
emsProbeConfigProbeLTIncTempTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe long-term increasing temperature time used for rate of change alarms.
|
|
|
|
Values are represented in whole number hours."
|
|
::= { emsProbeConfigEntry 18 }
|
|
|
|
emsProbeConfigProbeLTDecTempVariance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe long-term decreasing temperature variance used for rate of change alarms.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeConfigEntry 19 }
|
|
|
|
emsProbeConfigProbeLTDecTempTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe long-term decreasing temperature time used for rate of change alarms.
|
|
|
|
Values are represented in whole number hours."
|
|
::= { emsProbeConfigEntry 20 }
|
|
|
|
|
|
-- EMS INPUT CONTACT CONFIG STATUS TABLE
|
|
|
|
emsInputContactConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSInputContactConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual input contacts. The number of
|
|
entries is contained in the emsStatusInputContactCount OID."
|
|
::= { emsInputContactConfig 1 }
|
|
|
|
emsInputContactConfigEntry OBJECT-TYPE
|
|
SYNTAX EMSInputContactConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input contacts to configure."
|
|
INDEX { emsInputContactConfigInputContactIndex }
|
|
::= { emsInputContactConfigTable 1 }
|
|
|
|
EMSInputContactConfigEntry ::=
|
|
SEQUENCE {
|
|
emsInputContactConfigInputContactIndex INTEGER,
|
|
emsInputContactConfigInputContactName DisplayString,
|
|
emsInputContactConfigInputContactNormalState INTEGER
|
|
}
|
|
|
|
emsInputContactConfigInputContactIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the input contact entry."
|
|
::= { emsInputContactConfigEntry 1 }
|
|
|
|
emsInputContactConfigInputContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the input contact."
|
|
::= { emsInputContactConfigEntry 2 }
|
|
|
|
emsInputContactConfigInputContactNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyClosedEMS (1),
|
|
normallyOpenEMS (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the normal state of the input contact. If
|
|
the normal state is closed, the normallyClosedEMS (1) value will be returned.
|
|
If the normal state is closed, the normallyOpenEMS (2) value will be
|
|
returned.
|
|
|
|
Setting this variable will change the normal state of the input contact"
|
|
::= { emsInputContactConfigEntry 3 }
|
|
|
|
-- EMS OUTPUT RELAY CONFIG STATUS TABLE
|
|
|
|
emsOutputRelayConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSOutputRelayConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual output relays. The number of
|
|
entries is contained in the emsStatusOutputRelayCount OID."
|
|
::= { emsOutputRelayConfig 1 }
|
|
|
|
emsOutputRelayConfigEntry OBJECT-TYPE
|
|
SYNTAX EMSOutputRelayConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output relays to configure."
|
|
INDEX { emsOutputRelayConfigOutputRelayIndex }
|
|
::= { emsOutputRelayConfigTable 1 }
|
|
|
|
EMSOutputRelayConfigEntry ::=
|
|
SEQUENCE {
|
|
emsOutputRelayConfigOutputRelayIndex INTEGER,
|
|
emsOutputRelayConfigOutputRelayName DisplayString,
|
|
emsOutputRelayConfigOutputRelayNormalState INTEGER
|
|
}
|
|
|
|
emsOutputRelayConfigOutputRelayIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the output relay entry."
|
|
::= { emsOutputRelayConfigEntry 1 }
|
|
|
|
emsOutputRelayConfigOutputRelayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the output relay."
|
|
::= { emsOutputRelayConfigEntry 2 }
|
|
|
|
emsOutputRelayConfigOutputRelayNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyClosedEMS (1),
|
|
normallyOpenEMS (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the normal state of the output relay. If
|
|
the normal state is closed, the normallyClosedEMS (1) value will be returned.
|
|
If the normal state is closed, the normallyOpenEMS (2) value will be
|
|
returned.
|
|
|
|
Setting this variable will change the normal state of the output relay"
|
|
::= { emsOutputRelayConfigEntry 3 }
|
|
|
|
-- EMS OUTLET CONFIG TABLE
|
|
|
|
emsOutletConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual outlets. The number of
|
|
entries is contained in the emsStatusOutletCount OID."
|
|
::= { emsOutletConfig 1 }
|
|
|
|
emsOutletConfigEntry OBJECT-TYPE
|
|
SYNTAX EMSOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to configure."
|
|
INDEX { emsOutletConfigOutletIndex }
|
|
::= { emsOutletConfigTable 1 }
|
|
|
|
EMSOutletConfigEntry ::=
|
|
SEQUENCE {
|
|
emsOutletConfigOutletIndex INTEGER,
|
|
emsOutletConfigOutletName DisplayString,
|
|
emsOutletConfigOutletNormalState INTEGER
|
|
}
|
|
|
|
emsOutletConfigOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { emsOutletConfigEntry 1 }
|
|
|
|
emsOutletConfigOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet."
|
|
::= { emsOutletConfigEntry 2 }
|
|
|
|
emsOutletConfigOutletNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyOnEMS (1),
|
|
normallyOffEMS (2)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the normal state of the outlet. If
|
|
the normal state is on, the normallyOnEMS (1) value will be returned.
|
|
If the normal state is off, the normallyOffEMS (2) value will be
|
|
returned.
|
|
|
|
Setting this variable will change the normal state of the outlet"
|
|
::= { emsOutletConfigEntry 3 }
|
|
|
|
-- EMS SENSOR CONFIG TABLE
|
|
|
|
emsSensorConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSSensorConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual sensors. The number of
|
|
entries is contained in the emsStatusSensorCount OID."
|
|
::= { emsSensorConfig 1 }
|
|
|
|
emsSensorConfigEntry OBJECT-TYPE
|
|
SYNTAX EMSSensorConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensors to configure."
|
|
INDEX { emsSensorConfigSensorIndex }
|
|
::= { emsSensorConfigTable 1 }
|
|
|
|
EMSSensorConfigEntry ::=
|
|
SEQUENCE {
|
|
emsSensorConfigSensorIndex INTEGER,
|
|
emsSensorConfigSensorSystemName DisplayString,
|
|
emsSensorConfigSensorUserName DisplayString,
|
|
emsSensorConfigSensorNormalState INTEGER,
|
|
emsSensorConfigSensorAlarmDelay INTEGER
|
|
}
|
|
|
|
emsSensorConfigSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the sensor entry."
|
|
::= { emsSensorConfigEntry 1 }
|
|
|
|
emsSensorConfigSensorSystemName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system name of the sensor. This describes the hardware system
|
|
intent of this sensor."
|
|
::= { emsSensorConfigEntry 2 }
|
|
|
|
emsSensorConfigSensorUserName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the sensor as given by the system user."
|
|
::= { emsSensorConfigEntry 3 }
|
|
|
|
emsSensorConfigSensorNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyClosedEMS (1),
|
|
normallyOpenEMS (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the normal state of the sensor. If
|
|
the normal state is closed, the normallyClosedEMS (1) value will be returned.
|
|
If the normal state is closed, the normallyOpenEMS (2) value will be
|
|
returned.
|
|
|
|
Setting this variable will change the normal state of the sensor. Note:
|
|
Only the AUX sensor in the EMS has a configurable Normal State"
|
|
::= { emsSensorConfigEntry 4 }
|
|
|
|
emsSensorConfigSensorAlarmDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay (in seconds) after a sensor detects an alarm condition before the
|
|
condition is reported."
|
|
::= { emsSensorConfigEntry 5 }
|
|
|
|
-- EMS STATUS
|
|
--- EMS MASTER status
|
|
|
|
emsStatusEMSName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
device. "
|
|
::= { emsStatus 1 }
|
|
|
|
emsStatusCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noComm(1),
|
|
comm(2),
|
|
commLost(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The communication status between the agent
|
|
and the device.
|
|
|
|
noComm(1), Communication has never been established.
|
|
comm(2), Communication has been established.
|
|
commLost(3), Communication was established, but was lost."
|
|
::= { emsStatus 2 }
|
|
|
|
emsStatusProbeCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of T/H probes (both local and remote) that
|
|
is supported by this device."
|
|
::= { emsStatus 3 }
|
|
|
|
emsStatusInputContactCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of Input Contacts that
|
|
is supported by this device."
|
|
::= { emsStatus 4 }
|
|
|
|
emsStatusOutputRelayCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of Output Relays that
|
|
is supported by this device."
|
|
::= { emsStatus 5 }
|
|
|
|
emsStatusOutletCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of AC Outlets that
|
|
is supported by this device."
|
|
::= { emsStatus 6 }
|
|
|
|
emsStatusSensorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of Sensors that
|
|
is supported by this device."
|
|
::= { emsStatus 7 }
|
|
|
|
emsStatusAlinkAruDeviceCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of remote Aru's supported by this device."
|
|
::= { emsStatus 8 }
|
|
|
|
emsStatusAlinkProbeDeviceCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of remote T/H probes supported by this device."
|
|
::= { emsStatus 9 }
|
|
|
|
emsStatusAlarmDeviceCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of alarm devices supported by this device."
|
|
::= { emsStatus 10 }
|
|
|
|
emsStatusSysTempUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
celsius(1),
|
|
fahrenheit(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature scale used to display the temperature
|
|
in the system, Celsius(1) or Fahrenheit(2).
|
|
This setting is based on the system preferences
|
|
configuration in the agent."
|
|
::= { emsStatus 11 }
|
|
|
|
emsStatusCheckLogLight OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lightOff (1),
|
|
lightOn (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the check-log light on the device.
|
|
For the EMU2, this will always indicate lightOff(1).
|
|
|
|
lightOff (1) indicates the light is off (no new log entries).
|
|
lightOn (2) indicates the light is on (new log entries present)."
|
|
|
|
::= { emsStatus 12 }
|
|
|
|
emsStatusHardwareStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the EMS hardware. This integer should be interpreted
|
|
as a bit map, with each bit representing the presence or absence of
|
|
a specific hardware error condition.
|
|
|
|
0 indicates there are no error conditions detected in the EMS hardware.
|
|
1 indicates a Current Limit error condition related to the Alink port.
|
|
2 indicates incorrect hardware is plugged into an EMS port.
|
|
3 indicates that both of these error conditions are present."
|
|
|
|
::= { emsStatus 13 }
|
|
|
|
-- EMS PROBE STATUS TABLE
|
|
|
|
emsProbeStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSProbeStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for access of individual probes. The number of
|
|
entries is contained in the emsStatusProbeCount OID."
|
|
::= { emsProbeStatus 1 }
|
|
|
|
emsProbeStatusEntry OBJECT-TYPE
|
|
SYNTAX EMSProbeStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The probes to access."
|
|
INDEX { emsProbeStatusProbeIndex }
|
|
::= { emsProbeStatusTable 1 }
|
|
|
|
EMSProbeStatusEntry ::=
|
|
SEQUENCE {
|
|
emsProbeStatusProbeIndex INTEGER,
|
|
emsProbeStatusProbeName DisplayString,
|
|
emsProbeStatusProbeTemperature INTEGER,
|
|
emsProbeStatusProbeHighTempThresh INTEGER,
|
|
emsProbeStatusProbeLowTempThresh INTEGER,
|
|
emsProbeStatusProbeHumidity INTEGER,
|
|
emsProbeStatusProbeHighHumidityThresh INTEGER,
|
|
emsProbeStatusProbeLowHumidityThresh INTEGER,
|
|
emsProbeStatusProbeSerialNumber DisplayString,
|
|
emsProbeStatusProbeCommStatus INTEGER,
|
|
emsProbeStatusProbeAlarmStatus INTEGER,
|
|
emsProbeStatusProbeMaxTempThresh INTEGER,
|
|
emsProbeStatusProbeMinTempThresh INTEGER,
|
|
emsProbeStatusProbeMaxHumidityThresh INTEGER,
|
|
emsProbeStatusProbeMinHumidityThresh INTEGER
|
|
}
|
|
|
|
emsProbeStatusProbeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the probe entry."
|
|
::= { emsProbeStatusEntry 1 }
|
|
|
|
emsProbeStatusProbeName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the probe."
|
|
::= { emsProbeStatusEntry 2 }
|
|
|
|
emsProbeStatusProbeTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe temperature reading.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeStatusEntry 3 }
|
|
|
|
emsProbeStatusProbeHighTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe high temperature threshold.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeStatusEntry 4 }
|
|
|
|
emsProbeStatusProbeLowTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe low temperature threshold.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeStatusEntry 5 }
|
|
|
|
emsProbeStatusProbeHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe humidity reading.
|
|
|
|
Values are represented in whole number percentage."
|
|
::= { emsProbeStatusEntry 6 }
|
|
|
|
emsProbeStatusProbeHighHumidityThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe high humidity threshold.
|
|
|
|
Values are represented in whole number percentage."
|
|
::= { emsProbeStatusEntry 7 }
|
|
|
|
emsProbeStatusProbeLowHumidityThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe low humidity threshold.
|
|
|
|
Values are represented in whole number percentage."
|
|
::= { emsProbeStatusEntry 8 }
|
|
|
|
emsProbeStatusProbeSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A label indicating the type (Local[L] or Remote[R]) and Number
|
|
of the probe. For example, the first local probe would be L1 and
|
|
the third remote probe would be R3."
|
|
::= { emsProbeStatusEntry 9 }
|
|
|
|
emsProbeStatusProbeCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
commsNeverDiscovered(1),
|
|
commsEstablished(2),
|
|
commsLost(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The state of communications to the probe.
|
|
commNeverDiscovered(1) indicates there has never been communications with this device.
|
|
commsEstablished(2) indicates communication is normal and active with this device.
|
|
commsLost(3) indicates communication had been established, but is no longer."
|
|
::= { emsProbeStatusEntry 10 }
|
|
|
|
emsProbeStatusProbeAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm status of the probe. This integer should be interpreted
|
|
as a bit map, with each bit representing the presence or absence of
|
|
the specific alarm conditions listed below. The bit will be '1' if
|
|
the condition is present, and '0' if the condition is not present.
|
|
|
|
Bit Hex. Value Description
|
|
1 0x0001 Maximum temperature exceeded.
|
|
2 0x0002 High temperature exceeded.
|
|
3 0x0004 Low temperature exceeded.
|
|
4 0x0008 Minimum temperature exceeded.
|
|
5 0x0010 Short-term increasing temperature rate exceeded.
|
|
6 0x0020 Short-term decreasing temperature rate exceeded.
|
|
7 0x0040 Long-term increasing temperature rate exceeded.
|
|
8 0x0080 Long-term decreasing temperature rate exceeded.
|
|
9 0x0100 Maximum humidity exceeded.
|
|
10 0x0200 High humidity exceeded.
|
|
11 0x0400 Low humidity exceeded.
|
|
12 0x0800 Minimum humidity exceeded."
|
|
::= { emsProbeStatusEntry 11 }
|
|
|
|
emsProbeStatusProbeMaxTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe maximum temperature threshold.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeStatusEntry 12 }
|
|
|
|
emsProbeStatusProbeMinTempThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe minimum temperature threshold.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { emsProbeStatusEntry 13 }
|
|
|
|
emsProbeStatusProbeMaxHumidityThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe maximum humidity threshold.
|
|
|
|
Values are represented in whole number percentage."
|
|
::= { emsProbeStatusEntry 14 }
|
|
|
|
emsProbeStatusProbeMinHumidityThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probe minimum humidity threshold.
|
|
|
|
Values are represented in whole number percentage."
|
|
::= { emsProbeStatusEntry 15 }
|
|
|
|
|
|
-- EMS INPUT CONTACT STATUS TABLE
|
|
|
|
emsInputContactStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSInputContactStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for access of individual input contacts. The number of
|
|
entries is contained in the emsStatusInputContactCount OID."
|
|
::= { emsInputContactStatus 1 }
|
|
|
|
emsInputContactStatusEntry OBJECT-TYPE
|
|
SYNTAX EMSInputContactStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input contacts to access."
|
|
INDEX { emsInputContactStatusInputContactIndex }
|
|
::= { emsInputContactStatusTable 1 }
|
|
|
|
EMSInputContactStatusEntry ::=
|
|
SEQUENCE {
|
|
emsInputContactStatusInputContactIndex INTEGER,
|
|
emsInputContactStatusInputContactName DisplayString,
|
|
emsInputContactStatusInputContactState INTEGER,
|
|
emsInputContactStatusInputContactNormalState INTEGER
|
|
}
|
|
|
|
emsInputContactStatusInputContactIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the input contact entry."
|
|
::= { emsInputContactStatusEntry 1 }
|
|
|
|
emsInputContactStatusInputContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the input contact."
|
|
::= { emsInputContactStatusEntry 2 }
|
|
|
|
emsInputContactStatusInputContactState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
contactClosedEMS (1),
|
|
contactOpenEMS (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the state of the input contact. If
|
|
the input contact is closed, the contactClosedEMS (1) value will be returned.
|
|
If the input contact state is open, the contactOpenEMS (2) value will be
|
|
returned. "
|
|
|
|
::= { emsInputContactStatusEntry 3 }
|
|
|
|
emsInputContactStatusInputContactNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyClosedEMS (1),
|
|
normallyOpenEMS (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the normal state of the input contact. If
|
|
the normal state is closed, the normallyClosedEMS (1) value will be returned.
|
|
If the normal state is open, the normallyOpenEMS (2) value will be
|
|
returned. "
|
|
|
|
::= { emsInputContactStatusEntry 4 }
|
|
|
|
|
|
-- EMS OUTPUT RELAY STATUS TABLE
|
|
|
|
emsOutputRelayStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSOutputRelayStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for access of individual output relays. The number of
|
|
entries is contained in the emsStatusOutputRelayCount OID."
|
|
::= { emsOutputRelayStatus 1 }
|
|
|
|
emsOutputRelayStatusEntry OBJECT-TYPE
|
|
SYNTAX EMSOutputRelayStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output relays to access."
|
|
INDEX { emsOutputRelayStatusOutputRelayIndex }
|
|
::= { emsOutputRelayStatusTable 1 }
|
|
|
|
EMSOutputRelayStatusEntry ::=
|
|
SEQUENCE {
|
|
emsOutputRelayStatusOutputRelayIndex INTEGER,
|
|
emsOutputRelayStatusOutputRelayName DisplayString,
|
|
emsOutputRelayStatusOutputRelayState INTEGER,
|
|
emsOutputRelayStatusOutputRelayNormalState INTEGER
|
|
}
|
|
|
|
emsOutputRelayStatusOutputRelayIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the output relay entry."
|
|
::= { emsOutputRelayStatusEntry 1 }
|
|
|
|
emsOutputRelayStatusOutputRelayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the output relay."
|
|
::= { emsOutputRelayStatusEntry 2 }
|
|
|
|
emsOutputRelayStatusOutputRelayState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
relayClosedEMS (1),
|
|
relayOpenEMS (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the state of the output relay. If
|
|
the output relay is closed, the relayClosedEMS (1) value will be returned.
|
|
If the output relay is open, the relayOpenEMS (2) value will be
|
|
returned. "
|
|
|
|
::= { emsOutputRelayStatusEntry 3 }
|
|
|
|
emsOutputRelayStatusOutputRelayNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyClosedEMS (1),
|
|
normallyOpenEMS (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the normal state of the output relay. If
|
|
the normal state is closed, the normallyClosedEMS (1) value will be returned.
|
|
If the normal state is open, the normallyOpenEMS (2) value will be
|
|
returned. "
|
|
|
|
::= { emsOutputRelayStatusEntry 4 }
|
|
|
|
-- EMS OUTLET STATUS TABLE
|
|
|
|
emsOutletStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSOutletStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for access of individual outlets. The number of
|
|
entries is contained in the emsStatusOutletCount OID."
|
|
::= { emsOutletStatus 1 }
|
|
|
|
emsOutletStatusEntry OBJECT-TYPE
|
|
SYNTAX EMSOutletStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlets to access."
|
|
INDEX { emsOutletStatusOutletIndex }
|
|
::= { emsOutletStatusTable 1 }
|
|
|
|
EMSOutletStatusEntry ::=
|
|
SEQUENCE {
|
|
emsOutletStatusOutletIndex INTEGER,
|
|
emsOutletStatusOutletName DisplayString,
|
|
emsOutletStatusOutletState INTEGER,
|
|
emsOutletStatusOutletNormalState INTEGER
|
|
}
|
|
|
|
emsOutletStatusOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { emsOutletStatusEntry 1 }
|
|
|
|
emsOutletStatusOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet."
|
|
::= { emsOutletStatusEntry 2 }
|
|
|
|
emsOutletStatusOutletState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletOnEMS (1),
|
|
outletOffEMS (2)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the state of the outlet. If
|
|
the outlet is on, the outletOnEMS (1) value will be returned.
|
|
If the outlet is off, the outletOffEMS (2) value will be
|
|
returned. "
|
|
|
|
::= { emsOutletStatusEntry 3 }
|
|
|
|
emsOutletStatusOutletNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyOnEMS (1),
|
|
normallyOffEMS (2)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the normal state of the outlet. If
|
|
the normal state is on, the normallyOnEMS (1) value will be returned.
|
|
If the normal state is off, the normallyOffEMS (2) value will be
|
|
returned. "
|
|
|
|
::= { emsOutletStatusEntry 4 }
|
|
|
|
-- EMS ALARM DEVICE STATUS TABLE
|
|
|
|
emsAlarmDeviceStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSAlarmDeviceStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for access of individual alarm devices. The number of
|
|
entries is contained in the emsStatusAlarmDeviceCount OID."
|
|
::= { emsAlarmDeviceStatus 1 }
|
|
|
|
emsAlarmDeviceStatusEntry OBJECT-TYPE
|
|
SYNTAX EMSAlarmDeviceStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm devices to access."
|
|
INDEX { emsAlarmDeviceStatusDeviceIndex }
|
|
::= { emsAlarmDeviceStatusTable 1 }
|
|
|
|
EMSAlarmDeviceStatusEntry ::=
|
|
SEQUENCE {
|
|
emsAlarmDeviceStatusDeviceIndex INTEGER,
|
|
emsAlarmDeviceStatusDeviceName DisplayString,
|
|
emsAlarmDeviceStatusDeviceState INTEGER
|
|
}
|
|
|
|
emsAlarmDeviceStatusDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the alarm device entry."
|
|
::= { emsAlarmDeviceStatusEntry 1 }
|
|
|
|
emsAlarmDeviceStatusDeviceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the alarm device.
|
|
This OID is provided for informational purposes only."
|
|
::= { emsAlarmDeviceStatusEntry 2 }
|
|
|
|
emsAlarmDeviceStatusDeviceState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alarmDeviceOnEMS (1),
|
|
alarmDeviceOffEMS (2),
|
|
alarmDeviceNotInstalledEMS (3)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the device state. If
|
|
the device is active, the alarmDeviceOnEMS (1) value will be returned.
|
|
If the device is inactive, the alarmDeviceOffEMS (2) value will be
|
|
returned. If the device is not installed, the
|
|
alarmDeviceNotInstalledEMS (3) value will be returned."
|
|
|
|
::= { emsAlarmDeviceStatusEntry 3 }
|
|
|
|
|
|
-- EMS SENSOR STATUS TABLE
|
|
|
|
emsSensorStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EMSSensorStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for access of individual sensors. The number of
|
|
entries is contained in the emsStatusSensorCount OID."
|
|
::= { emsSensorStatus 1 }
|
|
|
|
emsSensorStatusEntry OBJECT-TYPE
|
|
SYNTAX EMSSensorStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensors to access."
|
|
INDEX { emsSensorStatusSensorIndex }
|
|
::= { emsSensorStatusTable 1 }
|
|
|
|
EMSSensorStatusEntry ::=
|
|
SEQUENCE {
|
|
emsSensorStatusSensorIndex INTEGER,
|
|
emsSensorStatusSensorSystemName DisplayString,
|
|
emsSensorStatusSensorName DisplayString,
|
|
emsSensorStatusSensorState INTEGER,
|
|
emsSensorStatusSensorNormalState INTEGER,
|
|
emsSensorStatusSensorAlarmDelay INTEGER
|
|
}
|
|
|
|
emsSensorStatusSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the sensor entry."
|
|
::= { emsSensorStatusEntry 1 }
|
|
|
|
emsSensorStatusSensorSystemName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system name of the sensor. This describes the hardware system
|
|
intent of this sensor."
|
|
::= { emsSensorStatusEntry 2 }
|
|
|
|
emsSensorStatusSensorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the sensor as given by the system user."
|
|
::= { emsSensorStatusEntry 3 }
|
|
|
|
emsSensorStatusSensorState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sensorFaultedEMS (1),
|
|
sensorOKEMS (2),
|
|
sensorNotInstalledEMS (3)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the sensor state. If the sensor is faulted,
|
|
the sensorFaultedEMS (1) value will be returned.
|
|
If the sensor is not faulted, the sensorOKEMS (2) value will be
|
|
returned. If the sensor is not installed, the sensorNotInstalledEMS (3)
|
|
value will be returned."
|
|
::= { emsSensorStatusEntry 4 }
|
|
|
|
emsSensorStatusSensorNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyClosedEMS (1),
|
|
normallyOpenEMS (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the normal state of the sensor. If
|
|
the normal state is closed, the normallyClosedEMS (1) value will be returned.
|
|
If the normal state is closed, the normallyOpenEMS (2) value will be
|
|
returned."
|
|
::= { emsSensorStatusEntry 5 }
|
|
|
|
emsSensorStatusSensorAlarmDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay (in seconds) after a sensor detects an alarm condition before the
|
|
condition is reported."
|
|
::= { emsSensorStatusEntry 6 }
|
|
|
|
|
|
|
|
-- airFM AIR CONDITIONER IDENT
|
|
|
|
airFMIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the device."
|
|
::= { airFMIdent 1 }
|
|
|
|
airFMIdentTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMIdentTable. "
|
|
::= { airFMIdent 2 }
|
|
|
|
airFMIdentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMIdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting identification information
|
|
from each module in the system. "
|
|
::= { airFMIdent 3 }
|
|
|
|
airFMIdentEntry OBJECT-TYPE
|
|
SYNTAX AirFMIdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module to get information from."
|
|
INDEX { airFMIdentModuleIndex }
|
|
::= { airFMIdentTable 1 }
|
|
|
|
AirFMIdentEntry ::=
|
|
SEQUENCE {
|
|
airFMIdentModuleIndex INTEGER,
|
|
airFMIdentModuleModelNumber DisplayString,
|
|
airFMIdentModuleDateOfMfg DisplayString,
|
|
airFMIdentModuleSerialNumber DisplayString,
|
|
airFMIdentModuleFirmwareRev DisplayString,
|
|
airFMIdentModuleHardwareRev DisplayString
|
|
}
|
|
|
|
airFMIdentModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the module information."
|
|
::= { airFMIdentEntry 1 }
|
|
|
|
airFMIdentModuleModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
model number. "
|
|
::= { airFMIdentEntry 2 }
|
|
|
|
airFMIdentModuleDateOfMfg OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
manufacture date. "
|
|
::= { airFMIdentEntry 3 }
|
|
|
|
airFMIdentModuleSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit serial number. "
|
|
::= { airFMIdentEntry 4 }
|
|
|
|
airFMIdentModuleFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
firmware revision. "
|
|
::= { airFMIdentEntry 5 }
|
|
|
|
airFMIdentModuleHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
hardware revision. "
|
|
::= { airFMIdentEntry 6 }
|
|
|
|
airFMIdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
location of the device. "
|
|
::= { airFMIdent 4 }
|
|
|
|
airFMIdentContact OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
person to contact regarding the device. "
|
|
::= { airFMIdent 5 }
|
|
|
|
|
|
-- airFM AIR CONDITIONER STATUS
|
|
|
|
airFMStatusSystemOn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusOn (1),
|
|
statusOff (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The operating state of the system.
|
|
This OID has been deprecated in favor of
|
|
airFMGroupSysStatus."
|
|
::= { airFMStatus 1 }
|
|
|
|
airFMStatusSystemAverageRetTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system average return air
|
|
temperature in tenths of degrees Celsius.
|
|
This OID has been deprecated in favor of
|
|
airFMSysAvgReturnTempC."
|
|
::= { airFMStatus 2 }
|
|
|
|
airFMStatusSystemAverageRetTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system average return air
|
|
temperature in tenths of degrees Fahrenheit.
|
|
This OID has been deprecated in favor of
|
|
airFMSysAvgReturnTempF."
|
|
::= { airFMStatus 3 }
|
|
|
|
airFMStatusSystemAverageRetHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system average return air
|
|
humidity in tenths of percent RH.
|
|
This OID has been deprecated in favor of
|
|
airFMSysAvgReturnHum."
|
|
::= { airFMStatus 4 }
|
|
|
|
airFMStatusSystemActionTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system action air
|
|
temperature in tenths of degrees Celsius.
|
|
This OID has been deprecated in favor of
|
|
airFMSysCtrlTempC."
|
|
::= { airFMStatus 5 }
|
|
|
|
airFMStatusSystemActionTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system action air
|
|
temperature in tenths of degrees Fahrenheit.
|
|
This OID has been deprecated in favor of
|
|
airFMSysCtrlTempF."
|
|
::= { airFMStatus 6 }
|
|
|
|
airFMStatusSystemActionHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system action air humidity in tenths of percent RH.
|
|
This OID has been deprecated in favor of
|
|
airFMSysCtrlHum."
|
|
::= { airFMStatus 7 }
|
|
|
|
airFMStatusSystemRemoteHighTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system remote high air
|
|
temperature in tenths of degrees Celsius.
|
|
This OID has been deprecated in favor of
|
|
airFMSysMaxRemoteTempC."
|
|
::= { airFMStatus 8 }
|
|
|
|
airFMStatusSystemRemoteHighTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system remote high air
|
|
temperature in tenths of degrees Fahrenheit.
|
|
This OID has been deprecated in favor of
|
|
airFMSysMaxRemoteTempF."
|
|
::= { airFMStatus 9 }
|
|
|
|
airFMStatusSystemRemoteAvgTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system remote average air
|
|
temperature in tenths of degrees Celsius.
|
|
This OID has been deprecated in favor of
|
|
airFMSysAvgRemoteTempC."
|
|
::= { airFMStatus 10 }
|
|
|
|
airFMStatusSystemRemoteAvgTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system remote average air
|
|
temperature in tenths of degrees Fahrenheit.
|
|
This OID has been deprecated in favor of
|
|
airFMSysAvgRemoteTempF."
|
|
::= { airFMStatus 11 }
|
|
|
|
airFMStatusSystemRemoteAvgHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system remote average air
|
|
humidity in tenths of percent RH.
|
|
This OID has been deprecated in favor of
|
|
airFMSysAvgRemoteHum."
|
|
::= { airFMStatus 12 }
|
|
|
|
airFMStatusSystemRemoteLowTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system remote low air
|
|
temperature in tenths of degrees Celsius.
|
|
This OID has been deprecated in favor of
|
|
airFMSysMinRemoteTempC."
|
|
::= { airFMStatus 13 }
|
|
|
|
airFMStatusSystemRemoteLowTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system remote low air
|
|
temperature in tenths of degrees Fahrenheit.
|
|
This OID has been deprecated in favor of
|
|
airFMSysMinRemoteTempF."
|
|
::= { airFMStatus 14 }
|
|
|
|
airFMStatusSystemCoolingEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabledYes (1),
|
|
enabledNo (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the system cooling
|
|
function enable.
|
|
This OID has been deprecated in favor of
|
|
airFMSysCoolState."
|
|
::= { airFMStatus 15 }
|
|
|
|
airFMStatusSystemReheatingEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabledYes (1),
|
|
enabledNo (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the system reheating
|
|
function enable.
|
|
This OID has been deprecated in favor of
|
|
airFMSysReheatState."
|
|
::= { airFMStatus 16 }
|
|
|
|
airFMStatusSystemHumidifyEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabledYes (1),
|
|
enabledNo (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the system humidify
|
|
function enable.
|
|
This OID has been deprecated in favor of
|
|
airFMSysHumState."
|
|
::= { airFMStatus 17 }
|
|
|
|
airFMStatusSystemDehumidifyEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabledYes (1),
|
|
enabledNo (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the system dehumidify
|
|
function enable.
|
|
This OID has been deprecated in favor of
|
|
airFMSysDehumState."
|
|
::= { airFMStatus 18 }
|
|
|
|
airFMStatusModuleTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMStatusModuleTable."
|
|
::= { airFMStatus 19 }
|
|
|
|
airFMStatusModuleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMStatusModuleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each module
|
|
in the system."
|
|
::= { airFMStatus 20 }
|
|
|
|
airFMStatusModuleEntry OBJECT-TYPE
|
|
SYNTAX AirFMStatusModuleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module to get status from."
|
|
INDEX { airFMStatusModuleIndex }
|
|
::= { airFMStatusModuleTable 1 }
|
|
|
|
AirFMStatusModuleEntry ::=
|
|
SEQUENCE {
|
|
airFMStatusModuleIndex INTEGER,
|
|
airFMStatusModuleOutputCapacity INTEGER,
|
|
airFMStatusModuleSupplyTempC INTEGER,
|
|
airFMStatusModuleSupplyTempF INTEGER,
|
|
airFMStatusModuleSupplyHum INTEGER,
|
|
airFMStatusModuleReturnTempC INTEGER,
|
|
airFMStatusModuleReturnTempF INTEGER,
|
|
airFMStatusModuleReturnHum INTEGER
|
|
}
|
|
|
|
airFMStatusModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the module information."
|
|
::= { airFMStatusModuleEntry 1 }
|
|
|
|
airFMStatusModuleOutputCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module output capacity in kilowatts.
|
|
This OID has been deprecated in favor of
|
|
airFMModOutputCapacity."
|
|
::= { airFMStatusModuleEntry 2 }
|
|
|
|
airFMStatusModuleSupplyTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module supply air temperature in
|
|
tenths of degrees Celsius.
|
|
This OID has been deprecated in favor of
|
|
airFMModSupplyTempC."
|
|
::= { airFMStatusModuleEntry 3 }
|
|
|
|
airFMStatusModuleSupplyTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module supply air temperature in
|
|
tenths of degrees Fahrenheit.
|
|
This OID has been deprecated in favor of
|
|
airFMModSupplyTempF."
|
|
::= { airFMStatusModuleEntry 4 }
|
|
|
|
airFMStatusModuleSupplyHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module supply air humidity in tenths of percent RH.
|
|
This OID has been deprecated in favor of
|
|
airFMModSupplyHum."
|
|
::= { airFMStatusModuleEntry 5 }
|
|
|
|
airFMStatusModuleReturnTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module return air temperature in
|
|
tenths of degrees Celsius.
|
|
This OID has been deprecated in favor of
|
|
airFMModReturnTempC."
|
|
::= { airFMStatusModuleEntry 6 }
|
|
|
|
airFMStatusModuleReturnTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module return air temperature in
|
|
tenths of degrees Fahrenheit.
|
|
This OID has been deprecated in favor of
|
|
airFMModReturnTempF."
|
|
::= { airFMStatusModuleEntry 7 }
|
|
|
|
airFMStatusModuleReturnHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module return air humidity in tenths of percent RH.
|
|
This OID has been deprecated in favor of
|
|
airFMModReturnHum."
|
|
::= { airFMStatusModuleEntry 8 }
|
|
|
|
-- airFM AIR CONDITIONER GROUP DATA
|
|
|
|
airFMGroupSysStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusOnLine (1),
|
|
statusIdle (2),
|
|
statusLoadShare (3),
|
|
statusOffLine (4),
|
|
statusFailed (5),
|
|
statusDisabled (6),
|
|
statusUndefined (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of this system within the group."
|
|
::= { airFMGroup 1 }
|
|
|
|
airFMGroupSysRuntime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of hours the system has been running."
|
|
::= { airFMGroup 2 }
|
|
|
|
airFMGroupSysRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rolePrimary (1),
|
|
roleBackup (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The role of this system within the group."
|
|
::= { airFMGroup 3 }
|
|
|
|
-- airFM Group System Roles
|
|
airFMGroupSysRolesTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMGroupSysRolesTable. "
|
|
::= { airFMGroupSysRoles 1 }
|
|
|
|
airFMGroupSysRolesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMGroupSysRolesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each system
|
|
in the group. "
|
|
::= { airFMGroupSysRoles 2 }
|
|
|
|
airFMGroupSysRolesEntry OBJECT-TYPE
|
|
SYNTAX AirFMGroupSysRolesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system to get status from."
|
|
INDEX { airFMGroupSysIndex }
|
|
::= { airFMGroupSysRolesTable 1 }
|
|
|
|
AirFMGroupSysRolesEntry ::=
|
|
SEQUENCE {
|
|
airFMGroupSysIndex INTEGER,
|
|
airFMGroupSysRoleStatus INTEGER,
|
|
airFMGroupSysPresentRole INTEGER,
|
|
airFMGroupSysManualRoleSetting INTEGER,
|
|
airFMGroupSysRunHours INTEGER,
|
|
airFMGroupSysComm INTEGER,
|
|
airFMGroupSysIPAddress IpAddress
|
|
}
|
|
|
|
airFMGroupSysIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the system information."
|
|
::= { airFMGroupSysRolesEntry 1 }
|
|
|
|
airFMGroupSysRoleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reserved1 (1),
|
|
reserved2 (2),
|
|
onLine (3),
|
|
idle (4),
|
|
loadShare (5),
|
|
failed (6),
|
|
offLine (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The present mode of the System."
|
|
::= { airFMGroupSysRolesEntry 2 }
|
|
|
|
airFMGroupSysPresentRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primary (1),
|
|
backup (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The present role of the System in a Group."
|
|
::= { airFMGroupSysRolesEntry 3 }
|
|
|
|
airFMGroupSysManualRoleSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primary (1),
|
|
backup (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The manual role setting of the System in a Group.
|
|
Only applies if Role Assignment Method is set
|
|
to static (Manually Assigned Roles)."
|
|
::= { airFMGroupSysRolesEntry 4 }
|
|
|
|
airFMGroupSysRunHours OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of hours the System has been
|
|
contributing to environmental control."
|
|
::= { airFMGroupSysRolesEntry 5 }
|
|
|
|
airFMGroupSysComm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
commLost (1),
|
|
commEstablished (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a system is communicating with the
|
|
other Systems in the Group."
|
|
::= { airFMGroupSysRolesEntry 6 }
|
|
|
|
airFMGroupSysIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP Address of the System."
|
|
::= { airFMGroupSysRolesEntry 7 }
|
|
|
|
airFMGroupSysRoleAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
staticManual (1),
|
|
dynamicAutomatic (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The method used to assign roles (i.e. Primary, Backup)
|
|
to the Systems in a Group.
|
|
|
|
staticManual: Manually assign Primary or Backup to
|
|
regulate run hours across the Group.
|
|
dynamicAutomatic: User indicates the number of Systems
|
|
that will be assigned a primary role in this Group."
|
|
::= { airFMGroupSysRoles 3 }
|
|
|
|
airFMGroupAutoRoleNumPrimary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
one (1),
|
|
two (2),
|
|
three (3),
|
|
four (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Systems assigned the 'primary' role in
|
|
this Group. Only applies if Role Assignment Method
|
|
is set to dynamic (Automatic Run Hour Balancing)."
|
|
::= { airFMGroupSysRoles 4 }
|
|
|
|
-- airFM Group Config
|
|
airFMGroupCfgName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the group name."
|
|
::= { airFMGroupCfg 1 }
|
|
|
|
airFMGroupCfgNumSystems OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
one (1),
|
|
two (2),
|
|
three (3),
|
|
four (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Systems in this Group."
|
|
::= { airFMGroupCfg 2 }
|
|
|
|
airFMGroupCfgIdleBlower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
minimumSpeed (2),
|
|
normalSpeed (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower behavior for backup Systems and Systems that
|
|
have entered a failure mode."
|
|
::= { airFMGroupCfg 3 }
|
|
|
|
airFMGroupCfgShutdownSmoke OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If enabled, all Systems in the Group will shut down
|
|
if smoke is detected."
|
|
::= { airFMGroupCfg 4 }
|
|
|
|
airFMGroupCfgShutdownFire OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If enabled, all Systems in the Group will shut down
|
|
if fire is detected."
|
|
::= { airFMGroupCfg 5 }
|
|
|
|
airFMGroupCfgFailoverCommLoss OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Failover on Comm Loss enables an available backup
|
|
System to run in place of a System that has lost
|
|
communication with the Group."
|
|
::= { airFMGroupCfg 6 }
|
|
|
|
airFMGroupCfgDmdFightStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Demand Fighting and Setpoint Sharing are
|
|
automatically enabled when a System is responding to
|
|
a Load Sharing Request."
|
|
::= { airFMGroupCfg 7 }
|
|
|
|
airFMGroupCfgDmdFightSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Demand Fighting prevents a System from engaging
|
|
reheat in a Group where any System is cooling."
|
|
::= { airFMGroupCfg 8 }
|
|
|
|
airFMGroupCfgSetpointShareStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Demand Fighting and Setpoint Sharing are
|
|
automatically enabled when a System is responding to
|
|
Load Sharing Request."
|
|
::= { airFMGroupCfg 9 }
|
|
|
|
airFMGroupCfgSetpointShareSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"All Systems in the Group use the same setpoints."
|
|
::= { airFMGroupCfg 10 }
|
|
|
|
airFMGroupCfgResetFieldServiceDefaults OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset(2) will reset all Group
|
|
parameters, which can only be edited by a field
|
|
service engineer, to their factory default values.
|
|
|
|
Getting this OID will do nothing and return the
|
|
noOperation(1) value."
|
|
::= { airFMGroupCfg 11 }
|
|
|
|
-- airFM Group Load Sharing
|
|
airFMGroupLoadShareCoolRequests OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Systems that are cooling may request assistance from
|
|
other Systems in the Group."
|
|
::= { airFMGroupLoadShare 1 }
|
|
|
|
airFMGroupLoadShareCoolThreshC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature threshold at which a System will generate
|
|
a load sharing request for cooling. Measured in
|
|
tenths of degrees Celsius."
|
|
::= { airFMGroupLoadShare 2 }
|
|
|
|
airFMGroupLoadShareCoolThreshF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature threshold at which a System will generate
|
|
a load sharing request for cooling. Measured in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airFMGroupLoadShare 3 }
|
|
|
|
airFMGroupLoadShareReheatRequests OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Systems that are reheating may request assistance
|
|
from other Systems in the Group."
|
|
::= { airFMGroupLoadShare 4 }
|
|
|
|
airFMGroupLoadShareReheatThreshC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature threshold at which a System will generate
|
|
a load sharing request for reheating. Measured in
|
|
tenths of degrees Celsius."
|
|
::= { airFMGroupLoadShare 5 }
|
|
|
|
airFMGroupLoadShareReheatThreshF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature threshold at which a System will generate
|
|
a load sharing request for reheating. Measured in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airFMGroupLoadShare 6 }
|
|
|
|
airFMGroupLoadShareHumRequests OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Systems that are humidifying may request humidification
|
|
assistance from other Systems in the Group."
|
|
::= { airFMGroupLoadShare 7 }
|
|
|
|
airFMGroupLoadShareHumThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidity threshold at which a System will generate a
|
|
load sharing request for humidification. Measured in
|
|
tenths of percent relative humidity."
|
|
::= { airFMGroupLoadShare 8 }
|
|
|
|
airFMGroupLoadShareDehumRequests OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Systems that are dehumidifying may request assistance
|
|
from other Systems in the Group."
|
|
::= { airFMGroupLoadShare 9 }
|
|
|
|
airFMGroupLoadShareDehumThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidity threshold at which a System will generate a
|
|
load sharing request for dehumidification. Measured in
|
|
tenths of percent relative humidity."
|
|
::= { airFMGroupLoadShare 10 }
|
|
|
|
-- airFM Group System Failover Events
|
|
airFMGroupFailoverSysAnyMinorAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if any minor system alarm is active.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 1 }
|
|
|
|
airFMGroupFailoverSysAnyMajorAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if any major system alarm is active.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 2 }
|
|
|
|
airFMGroupFailoverSysHighEnvTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the high environmental temperature
|
|
alarm is active.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 3 }
|
|
|
|
airFMGroupFailoverSysLowEnvTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the low environmental temperature
|
|
alarm is active.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 4 }
|
|
|
|
airFMGroupFailoverSysHighEnvHum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the high environmental humidity
|
|
alarm is active.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 5 }
|
|
|
|
airFMGroupFailoverSysLowEnvHum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the low environmental humidity
|
|
alarm is active.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 6 }
|
|
|
|
airFMGroupFailoverSysFireAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the fire alarm is active.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 7 }
|
|
|
|
airFMGroupFailoverSysSmokeAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the smoke alarm is active.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 8 }
|
|
|
|
airFMGroupFailoverSysCommLost OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the system has lost comm.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 9 }
|
|
|
|
airFMGroupFailoverSysSupplySensorFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the supply sensor has failed.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 10 }
|
|
|
|
airFMGroupFailoverSysReturnSensorFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the return sensor has failed.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 11 }
|
|
|
|
airFMGroupFailoverSysPrimarySensorFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the primary sensor has failed.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 12 }
|
|
|
|
airFMGroupFailoverSysSecondarySensorFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the secondary sensor has failed.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 13 }
|
|
|
|
airFMGroupFailoverSysNoSensorsAvailable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if no sensors are available.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverSys 14 }
|
|
|
|
-- airFM Group Module Failover Events
|
|
airFMGroupFailoverModMaintRequired OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if maintenance is required on a
|
|
module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 1 }
|
|
|
|
airFMGroupFailoverModCoolFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if cooling has failed on a module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 2 }
|
|
|
|
|
|
airFMGroupFailoverModHumFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the humidifier has failed on a
|
|
module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 3 }
|
|
|
|
airFMGroupFailoverModBlwrCntrl1Fail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if blower controller 1 has failed on
|
|
a module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 4 }
|
|
|
|
airFMGroupFailoverModBlwrCntrl2Fail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if blower controller 2 has failed on
|
|
a module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 5 }
|
|
|
|
airFMGroupFailoverModHighFilterDP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if a high filter differential
|
|
pressure is present on a module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 6 }
|
|
|
|
airFMGroupFailoverModHighSupplyTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if a high supply temperature is
|
|
active on a module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 7 }
|
|
|
|
airFMGroupFailoverModLowSupplyTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if a low supply temperature is active
|
|
on a module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 8 }
|
|
|
|
airFMGroupFailoverModLossOrLowAirFlow OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if there is a loss of air flow or low
|
|
air flow on a module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 9 }
|
|
|
|
airFMGroupFailoverModHumReplaceCylinder OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if a humidifier needs its cylinder
|
|
replaced on a module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 10 }
|
|
|
|
airFMGroupFailoverModAirBlockInterlockOpen OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the air block interlock is open
|
|
on a module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 11 }
|
|
|
|
airFMGroupFailoverModWaterDetected OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if water is detected by a module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 12 }
|
|
|
|
airFMGroupFailoverModCondensatePumpFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enabling this OID will cause the system to enter
|
|
a failure state if the condensate pump has failed in
|
|
a module.
|
|
Once in the failure state, environmental control
|
|
ceases for the system, and the blowers enter the
|
|
Idle Blower Operation mode.
|
|
A value of notApplicable indicates that this alarm
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMGroupFailoverMod 13 }
|
|
|
|
-- airFM System Status
|
|
|
|
airFMSysNumber OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
one (2),
|
|
two (3),
|
|
three (4),
|
|
four (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the system within the group.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 1 }
|
|
|
|
airFMSysPresentStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
reserved1 (2),
|
|
reserved2 (3),
|
|
onLine (4),
|
|
idle (5),
|
|
loadShare (6),
|
|
failed (7),
|
|
offLine (8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The present mode of the System.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 2 }
|
|
|
|
airFMSysPresentRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
primary (2),
|
|
backup (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The present role of the System in the Group.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 3 }
|
|
|
|
airFMSysRunHours OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of hours the System has been
|
|
contributing to environmental control.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 4 }
|
|
|
|
airFMSysCoilFluidTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the coolant at the fluid coil
|
|
inlet. Measured in degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 5 }
|
|
|
|
airFMSysCoilFluidTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the coolant at the fluid coil
|
|
inlet. Measured in degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 6 }
|
|
|
|
airFMSysHotWaterTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hot water temperature. Measured in degrees
|
|
Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 7 }
|
|
|
|
airFMSysHotWaterTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hot water temperature. Measured in degrees
|
|
Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 8 }
|
|
|
|
airFMSysAvgReturnTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average return temperature calculated from all
|
|
present modules. Measured in tenths of degrees
|
|
Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 9 }
|
|
|
|
airFMSysAvgReturnTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average return temperature calculated from all
|
|
present modules. Measured in tenths of degrees
|
|
Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 10 }
|
|
|
|
airFMSysAvgReturnHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average return humidity calculated from all
|
|
present modules. Measured in tenths of percent RH.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 11 }
|
|
|
|
airFMSysAvgRemoteTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average temperature calculated from all
|
|
operational remote sensors. Measured in tenths of
|
|
degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 12 }
|
|
|
|
airFMSysAvgRemoteTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average temperature calculated from all
|
|
operational remote sensors. Measured in tenths of
|
|
degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 13 }
|
|
|
|
airFMSysAvgRemoteHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average return humidity calculated from all
|
|
present modules. Measured in tenths of percent RH.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 14 }
|
|
|
|
airFMSysMaxRemoteTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum temperature reading from all operational
|
|
remote sensors. Measured in tenths of degrees
|
|
Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 15 }
|
|
|
|
airFMSysMaxRemoteTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum temperature reading from all operational
|
|
remote sensors. Measured in tenths of degrees
|
|
Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 16 }
|
|
|
|
airFMSysMinRemoteTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum temperature reading from all operational
|
|
remote sensors. Measured in tenths of degrees
|
|
Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 17 }
|
|
|
|
airFMSysMinRemoteTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum temperature reading from all operational
|
|
remote sensors. Measured in tenths of degrees
|
|
Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 18 }
|
|
|
|
airFMSysTempCtrlMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
avgReturn (2),
|
|
avgRemote (3),
|
|
maxRemote (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The method of environment temperature control
|
|
selected to regulate the temperature.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 19 }
|
|
|
|
airFMSysActualTempCtrlMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
avgReturn (2),
|
|
avgRemote (3),
|
|
maxRemote (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual method of environment temperature control
|
|
being used to regulate the temperature.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 20 }
|
|
|
|
airFMSysHumCtrlMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
avgReturnRH (2),
|
|
avgReturnDewPt (3),
|
|
avgRemoteRH (4),
|
|
avgRemoteDewPt (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The method of environment humidity control selected
|
|
to regulate the humidity.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 21 }
|
|
|
|
airFMSysActualHumCtrlMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
avgReturnRH (2),
|
|
avgReturnDewPt (3),
|
|
avgRemoteRH (4),
|
|
avgRemoteDewPt (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual method of environment humidity control
|
|
being used to regulate the humidity.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 22 }
|
|
|
|
airFMSysCtrlTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system environmental control air temperature from
|
|
the sensor denoted by airFMSysActualTempCtrl.
|
|
Measured in tenths of degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 23 }
|
|
|
|
airFMSysCtrlTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system environmental control air temperature from
|
|
the sensor denoted by airFMSysActualTempCtrl.
|
|
Measured in tenths of degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 24 }
|
|
|
|
airFMSysCtrlHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system environmental control air humidity from
|
|
the sensor denoted by airFMSysActualHumCtrl.
|
|
Measured in percent relative humidity.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysStatus 25 }
|
|
|
|
-- airFM System Demands and Actuals
|
|
|
|
airFMSysDXCoolingDmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The direct expansion cooling output demanded by the
|
|
System. Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 1 }
|
|
|
|
airFMSysDXDehumDmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The direct expansion dehumidification output demanded
|
|
by the System. Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 2 }
|
|
|
|
airFMSysDXActualCoolDehum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The direct expansion cooling or dehumidification
|
|
output measured by the System. Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 3 }
|
|
|
|
airFMSysCoilFluidCoolDmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fluid coil cooling output demanded by the System.
|
|
Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 4 }
|
|
|
|
airFMSysCoilFluidDehumDmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fluid coil dehumidification output demanded by
|
|
the System. Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 5 }
|
|
|
|
airFMSysCoilFluidActualCoolDehum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fluid coil cooling or dehumidification output
|
|
measured by the System. Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 6 }
|
|
|
|
airFMSysElectricReheatDmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The electric reheating output demanded by the System.
|
|
Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 7 }
|
|
|
|
airFMSysActualElectricReheat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The electric reheating output of the System.
|
|
Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 8 }
|
|
|
|
airFMSysSteamHotGasReheatDmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The steam, hot water, or hot gas reheating output
|
|
demanded by the System.
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 9 }
|
|
|
|
airFMSysActualSteamHotGasReheat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The steam, hot water, or hot gas reheating output of
|
|
the System.
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 10 }
|
|
|
|
airFMSysSteamElectrodeHumDmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The steam electrode humidification output demanded by
|
|
the System. Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 11 }
|
|
|
|
airFMSysActualSteamElectrodeHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average steam electrode humidification output
|
|
measured for the Modules in the System. Measured in
|
|
percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 12 }
|
|
|
|
airFMSysSteamHumDmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The steam humidification output demanded by the System.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 13 }
|
|
|
|
airFMSysActualSteamHum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The steam humidification output for the System.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDemands 14 }
|
|
|
|
-- airFM System Physical Setup
|
|
|
|
airFMSysNumModules OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
one (2),
|
|
two (3),
|
|
three (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Modules in this System.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 1 }
|
|
|
|
airFMSysNumPCIOMs OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
one (2),
|
|
two (3),
|
|
three (4),
|
|
four (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Programmable Customer Input/Output
|
|
Modules (PCIOMs) installed in the Main Module of this
|
|
System. Each PCIOM adds four input contacts and four
|
|
output relays to the System.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 2 }
|
|
|
|
airFMSysMainsVlt OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The mains voltage for the Modules in this System.
|
|
A value of N/A indicates that this OID does not apply
|
|
to this device due to its configuration."
|
|
::= { airFMSysSetup 3 }
|
|
|
|
airFMSysUPSVlt OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS voltage for the Modules in this System.
|
|
A value of N/A indicates that this OID does not apply
|
|
to this device due to its configuration."
|
|
::= { airFMSysSetup 4 }
|
|
|
|
airFMSysCoilCfg OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
dx (2),
|
|
econ (3),
|
|
multicool (4),
|
|
chilledWater (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of cooling coils installed in the Modules in
|
|
this System: DX coil, DX and MultiCool (chilled water)
|
|
coils, DX and Economizer coils, or only a Chilled
|
|
Liquid coil.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 5 }
|
|
|
|
airFMSysRefrigType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
r22 (2),
|
|
r407C (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of refrigerant used by each compressor in
|
|
the system.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 6 }
|
|
|
|
airFMSysHeatRejection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
airCooled (2),
|
|
waterCooled (3),
|
|
glycolCooled (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The method the Modules in this System use to transfer
|
|
heat away from the refrigerant.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 7 }
|
|
|
|
airFMSysDischAirPtrn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
upFlow (2),
|
|
downFlow (3),
|
|
horizFlow (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The discharge air pattern for the Modules in this
|
|
System.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 8 }
|
|
|
|
airFMSysAirFltr OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
standard (2),
|
|
highEfficiency (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of air filters (standard or high efficiency)
|
|
installed in the Modules of this System.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 9 }
|
|
|
|
airFMSysFlowSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
none (2),
|
|
dxEcon (3),
|
|
multiCoolChillWater (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the optional flow switch.
|
|
None: No flow switch is installed in this System.
|
|
DX: Coolant input to the heat exchanger (condenser).
|
|
MultiCool: Chilled water input to the MultiCool coil.
|
|
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 10 }
|
|
|
|
airFMSysCoilFluidVlvAct OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
none (2),
|
|
springAnalog (3),
|
|
floatingControl (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of valve actuator installed on the coil
|
|
fluid valve. The coil fluid valve controls the flow
|
|
of coolant into a fluid cooling coil, such as a
|
|
MultiCool or Economizer coil.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 11 }
|
|
|
|
airFMSysCoilFluidVlvType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
twoWay (2),
|
|
threeWay (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of coil fluid valve installed for the
|
|
Modules in this System.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 12 }
|
|
|
|
airFMSysCndsrFluidVlvAct OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
none (2),
|
|
floatingControl (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of valve actuator installed on the Condenser
|
|
fluid valve. The Condenser fluid valve controls the
|
|
flow of coolant into the heat exchanger (condenser)
|
|
to regulate head pressure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 13 }
|
|
|
|
airFMSysCndsrFluidVlvType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
twoWay (2),
|
|
threeWay (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of Condenser fluid valve installed for the
|
|
Modules in this System.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 14 }
|
|
|
|
airFMSysHotWaterVlvAct OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
none (2),
|
|
springAnalog (3),
|
|
floatingControl (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of valve actuator installed on the hot water
|
|
valve.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysSetup 15 }
|
|
|
|
airFMSysNumRemoteSensors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of remote sensors detected by the system."
|
|
::= { airFMSysSetup 16 }
|
|
|
|
-- airFM System Configuration
|
|
|
|
airFMSysPrimaryControlSensor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
return (2),
|
|
remote (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selects whether return or remote sensors will control
|
|
the system.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysConfig 1 }
|
|
|
|
airFMSysRemoteSensorData OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
average (2),
|
|
maximum (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selects whether average temperature or max temperature
|
|
will be used when remote sensors are selected for
|
|
control of the system.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysConfig 2 }
|
|
|
|
airFMSysFastStartup OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimizes the time for the cooling process to begin
|
|
after other delay constraints have been met.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysConfig 3 }
|
|
|
|
airFMSysStartupDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the delay that begins when power is applied and
|
|
ends when the System starts. This allows you to
|
|
create a staged restart among your Systems after a
|
|
power loss. Measured in seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysConfig 4 }
|
|
|
|
airFMSysModeDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the delay between starting the blowers and
|
|
engaging the modes. It allows the sensors to read
|
|
room conditions accurately and allows the controller
|
|
to check for major alarms before engaging a mode.
|
|
Measured in seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysConfig 5 }
|
|
|
|
airFMSysCommLossShutdownDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the delay between an Expansion Module losing
|
|
communication with the Main Module and the Expansion
|
|
Module shutting down. A value of -1 will keep
|
|
the Expansion Module running after a communication
|
|
loss. Measured in hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysConfig 6 }
|
|
|
|
airFMSysResetSysFailure OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset(2) will allows the system
|
|
to return from any failure condition, if the
|
|
failure(s) have cleared.
|
|
Getting this OID will do nothing and return the noOperation(1) value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysConfig 7 }
|
|
|
|
airFMSysResetUserDflts OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset(2) will reset all system
|
|
parameters that can be edited by the user to their
|
|
factory default values.
|
|
Getting this OID will do nothing and return the noOperation(1) value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysConfig 8 }
|
|
|
|
airFMSysResetFldSrvcDflts OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset(2) will reset all system
|
|
parameters that can only be edited by the field
|
|
service engineer to their factory default values.
|
|
Getting this OID will do nothing and return the noOperation(1) value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysConfig 9 }
|
|
|
|
airFMSysResetRunHours OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset(2) will reset the system Run Hours.
|
|
Getting this OID will do nothing and return the noOperation(1) value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysConfig 10 }
|
|
|
|
-- airFM System Cooling
|
|
|
|
airFMSysCompMinOnTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the minimum time the compressor continues to
|
|
operate after it is started. The delay protects the
|
|
compressor from damage. Caution: Reducing this delay
|
|
shortens compressor life. Measured in seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 1 }
|
|
|
|
airFMSysCompMinOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the minimum time the compressor will remain off
|
|
after it ceases operation. The delay protects the
|
|
compressor from damage. Caution: Reducing this delay
|
|
shortens compressor life. Measured in seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 2 }
|
|
|
|
airFMSysCompRotPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set how often to perform compressor runtime
|
|
balancing. Measured in hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 3 }
|
|
|
|
airFMSysEconIsolVlvOpenDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the delay between opening the Economizer Isolator
|
|
output relay and engaging the compressors. Measured
|
|
in seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 4 }
|
|
|
|
airFMSysEconIsolVlvCloseDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the delay between disengaging the compressor and
|
|
closing the Economizer Isolator output relay.
|
|
Measured in seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 5 }
|
|
|
|
airFMSysCndsrFluidVlvCloseDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the time the condenser valve remains open after
|
|
the compressors disengage. Measured in seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 6 }
|
|
|
|
airFMSysInterstageDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The DX interstage delay allows the first compressor's
|
|
cooling to take effect before engaging the second
|
|
compressor. This prevents the second compressor from
|
|
cycling on and off excessively. Measured in seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 7 }
|
|
|
|
airFMSysCoolState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the mode to enabled or disabled. Disabled modes
|
|
will not operate, and you cannot make changes to
|
|
their settings while they are disabled.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 8 }
|
|
|
|
airFMSysCoolEssFunction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
yes (2),
|
|
no (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the priority of the mode for alarms and events
|
|
with the nonessential stop behavior. Nonessential
|
|
modes are disabled during nonessential stop alarms
|
|
and events.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 9 }
|
|
|
|
airFMSysCoolSetpointC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The target value for the selected control sensor air
|
|
for this mode. It must be at least 1.0 C above the
|
|
reheat setpoint if a heater is installed. Measured
|
|
in tenths of degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 10 }
|
|
|
|
airFMSysCoolSetpointF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The target value for the selected control sensor air
|
|
for this mode. It must be at least 1.0 C above the
|
|
reheat setpoint if a heater is installed. Measured
|
|
in tenths of degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 11 }
|
|
|
|
airFMSysCoolDeadbandC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature range that controls output when the
|
|
selected control sensor temperature is above the
|
|
setpoint. At the top of this range, the cool mode
|
|
outputs at 100%. The deadband does not apply to PID-
|
|
controlled modes. Measured in tenths of degrees
|
|
Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 12 }
|
|
|
|
airFMSysCoolDeadbandF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature range that controls output when the
|
|
selected control sensor temperature is above the
|
|
setpoint. At the top of this range, the cool mode
|
|
outputs at 100%. The deadband does not apply to PID-
|
|
controlled modes. Measured in tenths of degrees
|
|
Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 13 }
|
|
|
|
airFMSysCoolEconIsolFunction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the Economizer Automatic Coolant Isolation valve
|
|
to enabled or disabled. This valve anticipates a
|
|
cooling demand and opens the coil fluid valve.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 14 }
|
|
|
|
airFMSysSuctPresCompensation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the Suction Pressure Compensation to enabled or
|
|
disabled. This function attempts to keep the suction
|
|
pressure from exceeding 95 psi.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 15 }
|
|
|
|
airFMSysCoilFluidActivThreshC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum coolant temperature required to use the
|
|
optional MultiCool or Economizer coil. Measured in
|
|
tenths of degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 16 }
|
|
|
|
airFMSysCoilFluidActivThreshF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum coolant temperature required to use the
|
|
optional MultiCool or Economizer coil. Measured in
|
|
tenths of degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 17 }
|
|
|
|
airFMSysCoilFluidActivDeadbandC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The controller will disengage the MultiCool or
|
|
Economizer coil when the coolant temperature reaches
|
|
the coil fluid temperature activation threshold plus
|
|
the deadband. Measured in tenths of degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 18 }
|
|
|
|
airFMSysCoilFluidActivDeadbandF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The controller will disengage the MultiCool or
|
|
Economizer coil when the coolant temperature reaches
|
|
the coil fluid temperature activation threshold plus
|
|
the deadband. Measured in tenths of degrees
|
|
Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 19 }
|
|
|
|
airFMSysCoolPIDMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
p (2),
|
|
pi (3),
|
|
pid (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the multipliers that the PID algorithm will use
|
|
to calculate the cool output. Proportional,
|
|
Proportional + Integral, or Proportional + Integral
|
|
+ Derivative.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 20 }
|
|
|
|
airFMSysCoolPIDGainP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the proportional multiplier to correct for
|
|
differences between the selected control sensor
|
|
actual temperature and the setpoint. Measured in
|
|
%/C.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 21 }
|
|
|
|
airFMSysCoolPIDResetRateI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the integral multiplier to correct for the
|
|
proportional offset. Measured in %/(C * min).
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 22 }
|
|
|
|
airFMSysCoolPIDDerivativeD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the derivative multiplier to counteract overshoot
|
|
and droop during changes in the room load. Measured
|
|
in %/(C / min).
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysCooling 23 }
|
|
|
|
-- airFM System Humidify Function
|
|
|
|
airFMSysHumState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the mode to enabled or disabled. Disabled modes
|
|
will not operate, and you cannot make changes to their
|
|
settings while they are disabled.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysHumidify 1 }
|
|
|
|
airFMSysHumEssFunction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
yes (2),
|
|
no (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the priority of the mode for alarms and events
|
|
with the nonessential stop behavior. Nonessential
|
|
modes are disabled during nonessential stop alarms
|
|
and events.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysHumidify 2 }
|
|
|
|
airFMSysHumSetpoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The target value for the selected control sensor air
|
|
for this mode. It must be at least 1.0 % RH below
|
|
the dehumidification setpoint. Measured in tenths of
|
|
percent relative humidity.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysHumidify 3 }
|
|
|
|
airFMSysHumDeadband OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidity range that controls output when the
|
|
selected control sensor humidity is below the
|
|
setpoint. At the top of this range, the
|
|
humidification mode outputs at 100%. The deadband
|
|
does not apply to PID-controlled modes. Measured in
|
|
tenths of percent relative humidity.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysHumidify 4 }
|
|
|
|
airFMSysHumCtrlSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
relativeHum (2),
|
|
dewPoint (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the method to control the humidity in the room.
|
|
The two methods are Relative Humidity (RH) or Dew
|
|
Point of the selected control sensor air. The dew
|
|
point method helps correct for hot spots near the
|
|
selected control sensors.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysHumidify 5 }
|
|
|
|
airFMSysActualHumCtrl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
relativeHum (2),
|
|
dewPoint (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidity control method the system is using.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysHumidify 6 }
|
|
|
|
airFMSysHumSensBand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percentage of relative humidity below the
|
|
setpoint at which the humidifier will output at 100%
|
|
of capacity. Measured in percent relative humidity.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysHumidify 7 }
|
|
|
|
-- airFM System Dehumidify Function
|
|
|
|
airFMSysDehumState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the mode to enabled or disabled. Disabled modes
|
|
will not operate, and you cannot make changes to their
|
|
settings while they are disabled.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDehumidify 1 }
|
|
|
|
airFMSysDehumEssFunction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
yes (2),
|
|
no (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the priority of the mode for alarms and events
|
|
with the nonessential stop behavior. Nonessential
|
|
modes are disabled during nonessential stop alarms
|
|
and events.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDehumidify 2 }
|
|
|
|
airFMSysDehumSetpoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The target value for the selected control sensor air
|
|
for this mode. It must be at least 1.0 % RH above
|
|
the humidification setpoint if a humidifier is
|
|
installed. Measured in tenths of percent relative
|
|
humidity.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDehumidify 3 }
|
|
|
|
airFMSysDehumDeadband OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidity range above the setpoint at which the
|
|
dehumidification mode will output at 100%. The
|
|
deadband does not apply to PID controlled modes.
|
|
Measured in tenths of percent relative humidity.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDehumidify 4 }
|
|
|
|
airFMSysDehumCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
half (2),
|
|
full (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the dehumidification mode to use either half of
|
|
the cooling coil or the full coil when dehumidifying
|
|
the room.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDehumidify 5 }
|
|
|
|
airFMSysDehumPIDMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
p (2),
|
|
pi (3),
|
|
pid (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the multipliers that the PID algorithm will use
|
|
to calculate the output. Proportional,
|
|
Proportional + Integral, or Proportional + Integral
|
|
+ Derivative.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDehumidify 6 }
|
|
|
|
airFMSysDehumPIDGainP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the proportional multiplier to correct for
|
|
differences between the selected control sensor
|
|
actual humidity and the setpoint. Measured in %/%RH.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDehumidify 7 }
|
|
|
|
airFMSysDehumPIDResetRateI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the integral multiplier to correct for the
|
|
proportional offset. Measured in %/(%RH * min).
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDehumidify 8 }
|
|
|
|
airFMSysDehumPIDDerivativeD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the derivative multiplier to counteract overshoot
|
|
and droop during changes in the room humidity.
|
|
Measure in %/(%RH / min).
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysDehumidify 9 }
|
|
|
|
-- airFM System Reheat Function
|
|
|
|
airFMSysReheatState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the mode to enabled or disabled. Disabled modes
|
|
will not operate, and you cannot make changes to their
|
|
settings while they are disabled.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysReheat 1 }
|
|
|
|
airFMSysReheatEssFunction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
yes (2),
|
|
no (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the priority of the mode for alarms and events
|
|
with the nonessential stop behavior. Nonessential
|
|
modes are disabled during nonessential stop alarms
|
|
and events.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysReheat 2 }
|
|
|
|
airFMSysReheatSetpointC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The target value for the selected control sensor air
|
|
for this mode. It must be at least 1.0 C below the
|
|
cooling setpoint. Measured in tenths of degrees
|
|
Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysReheat 3 }
|
|
|
|
airFMSysReheatSetpointF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The target value for the selected control sensor air
|
|
for this mode. It must be at least 1.0 C below the
|
|
cooling setpoint. Measured in tenths of degrees
|
|
Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysReheat 4 }
|
|
|
|
airFMSysReheatDeadbandC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature range that controls output when the
|
|
selected control sensor temperature is below the
|
|
setpoint. At the bottom of this range, the reheat
|
|
mode outputs at 100%. The deadband does not apply to
|
|
PID-controlled modes. Measured in tenths of degrees
|
|
Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysReheat 5 }
|
|
|
|
airFMSysReheatDeadbandF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature range that controls output when the
|
|
selected control sensor temperature is below the
|
|
setpoint. At the bottom of this range, the reheat
|
|
mode outputs at 100%. The deadband does not apply to
|
|
PID-controlled modes. Measured in tenths of degrees
|
|
Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysReheat 6 }
|
|
|
|
airFMSysReheatPIDMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
p (2),
|
|
pi (3),
|
|
pid (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the multipliers that the PID algorithm will use
|
|
to calculate the output. Proportional,
|
|
Proportional + Integral, or Proportional + Integral
|
|
+ Derivative.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysReheat 7 }
|
|
|
|
airFMSysReheatPIDGainP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the proportional multiplier to correct for
|
|
differences between the selected control sensor
|
|
actual temperature and the setpoint. Measured in
|
|
%/C.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysReheat 8 }
|
|
|
|
airFMSysReheatPIDResetRateI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the integral multiplier to correct for the
|
|
proportional offset. Measured in %/(C * min).
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysReheat 9 }
|
|
|
|
airFMSysReheatPIDDerivativeD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the derivative multiplier to counteract overshoot
|
|
and droop during changes in the room load. Measured
|
|
in %/(C / min).
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysReheat 10 }
|
|
|
|
-- airFM System Thresholds
|
|
|
|
airFMSysHighSplyTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature threshold for air blown into the
|
|
room (supply). If the supply temperature exceeds the
|
|
threshold, an alarm will occur. Measured in tenths
|
|
of degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 1 }
|
|
|
|
airFMSysHighSplyTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature threshold for air blown into the
|
|
room (supply). If the supply temperature exceeds the
|
|
threshold, an alarm will occur. Measured in tenths
|
|
of degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 2 }
|
|
|
|
airFMSysLowSplyTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature threshold for air blown into the
|
|
room (supply). If the supply temperature drops below
|
|
the threshold, an alarm will occur. Measured in
|
|
tenths of degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 3 }
|
|
|
|
airFMSysLowSplyTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature threshold for air blown into the
|
|
room (supply). If the supply temperature drops below
|
|
the threshold, an alarm will occur. Measured in
|
|
tenths of degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 4 }
|
|
|
|
airFMSysHighCoilFluidTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature threshold for coolant at the
|
|
inlet to the fluid coil. If the fluid coil coolant
|
|
temperature exceeds the threshold, an alarm will
|
|
occur. Measured in tenths of degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 5 }
|
|
|
|
airFMSysHighCoilFluidTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature threshold for coolant at the
|
|
inlet to the fluid coil. If the fluid coil coolant
|
|
temperature exceeds the threshold, an alarm will
|
|
occur. Measured in tenths of degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 6 }
|
|
|
|
airFMSysLowCoilFluidTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature threshold for coolant at the
|
|
inlet to the fluid coil. If the fluid coil coolant
|
|
temperature drops below the threshold, an alarm will
|
|
occur. Measured in tenths of degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 7 }
|
|
|
|
airFMSysLowCoilFluidTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature threshold for coolant at the
|
|
inlet to the fluid coil. If the fluid coil coolant
|
|
temperature drops below the threshold, an alarm will
|
|
occur. Measured in tenths of degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 8 }
|
|
|
|
airFMSysHighCtrlTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature threshold for air monitored by
|
|
the System. If the temperature exceeds the threshold,
|
|
an alarm will occur. Measured in tenths of degrees
|
|
Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 9 }
|
|
|
|
airFMSysHighCtrlTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature threshold for air monitored by
|
|
the System. If the temperature exceeds the threshold,
|
|
an alarm will occur. Measured in tenths of degrees
|
|
Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 10 }
|
|
|
|
airFMSysLowCtrlTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature threshold for air monitored by
|
|
the System. If the temperature drops below the
|
|
threshold, an alarm will occur. Measured in tenths
|
|
of degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 11 }
|
|
|
|
airFMSysLowCtrlTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature threshold for air monitored by
|
|
the System. If the temperature drops below the
|
|
threshold, an alarm will occur. Measured in tenths
|
|
of degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 12 }
|
|
|
|
airFMSysHighCtrlHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high humidity threshold for air monitored by the
|
|
System. If the humidity exceeds the threshold, an
|
|
alarm will occur. Measured in tenths of percent
|
|
relative humidity.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 13 }
|
|
|
|
airFMSysLowCtrlHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low humidity threshold for air monitored by the
|
|
System. If the humidity drops below the threshold,
|
|
an alarm will occur. Measured in tenths of percent
|
|
relative humidity.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 14 }
|
|
|
|
airFMSysTempAlarmDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time the blower must be on before a
|
|
temperature alarm can be issued. Measured in
|
|
seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 15 }
|
|
|
|
airFMSysHumAlarmDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time the blower must be on before a
|
|
humidity alarm can be issued. Measured in seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysThresholds 16 }
|
|
|
|
-- airFM System Input Contacts
|
|
|
|
airFMSysInputTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMSysInputTable. "
|
|
::= { airFMSysInputs 1 }
|
|
|
|
airFMSysInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMSysInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each input
|
|
contact."
|
|
::= { airFMSysInputs 2 }
|
|
|
|
airFMSysInputEntry OBJECT-TYPE
|
|
SYNTAX AirFMSysInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input contact to obtain status from."
|
|
INDEX { airFMSysInputIndex }
|
|
::= { airFMSysInputTable 1 }
|
|
|
|
AirFMSysInputEntry ::=
|
|
SEQUENCE {
|
|
airFMSysInputIndex INTEGER,
|
|
airFMSysInputName DisplayString,
|
|
airFMSysInputStatus INTEGER,
|
|
airFMSysInputNormalState INTEGER,
|
|
airFMSysInputDelay INTEGER,
|
|
airFMSysInputAlarmAction INTEGER
|
|
}
|
|
|
|
airFMSysInputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number designator of the Input Contact."
|
|
::= { airFMSysInputEntry 1 }
|
|
|
|
airFMSysInputName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The configurable name for the Input Contact. Maximum
|
|
text input is 13 characters."
|
|
::= { airFMSysInputEntry 2 }
|
|
|
|
airFMSysInputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of this contact: Open or Closed. A
|
|
violation will occur when this relay is not in its
|
|
normal state."
|
|
::= { airFMSysInputEntry 3 }
|
|
|
|
airFMSysInputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the normal state of this contact (the state when
|
|
no alarm/event exists)."
|
|
::= { airFMSysInputEntry 4 }
|
|
|
|
airFMSysInputDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the delay between this contact exiting its normal
|
|
state and an alarm being triggered. Measured in
|
|
seconds."
|
|
::= { airFMSysInputEntry 5 }
|
|
|
|
airFMSysInputAlarmAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusOnly (1),
|
|
minor (2),
|
|
major (3),
|
|
remoteRunStop (4),
|
|
nonessStop (5),
|
|
immShutdown (6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sets the behavior for this contact when it exits its
|
|
normal state."
|
|
::= { airFMSysInputEntry 6 }
|
|
|
|
-- airFM System Output Relays
|
|
|
|
airFMSysOutputTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMSysOutputTable. "
|
|
::= { airFMSysOutputs 1 }
|
|
|
|
airFMSysOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMSysOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each output relay. "
|
|
::= { airFMSysOutputs 2 }
|
|
|
|
airFMSysOutputEntry OBJECT-TYPE
|
|
SYNTAX AirFMSysOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output relay to obtain status from."
|
|
INDEX { airFMSysOutputIndex }
|
|
::= { airFMSysOutputTable 1 }
|
|
|
|
AirFMSysOutputEntry ::=
|
|
SEQUENCE {
|
|
airFMSysOutputIndex INTEGER,
|
|
airFMSysOutputStatus INTEGER,
|
|
airFMSysOutputNormalState INTEGER
|
|
}
|
|
|
|
airFMSysOutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number designator of the output relay."
|
|
::= { airFMSysOutputEntry 1 }
|
|
|
|
airFMSysOutputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of this relay: Open or Closed. A violation
|
|
will occur when this relay is not in its normal state."
|
|
::= { airFMSysOutputEntry 2 }
|
|
|
|
airFMSysOutputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the normal state of this relay (the state when no
|
|
alarm/event exists)."
|
|
::= { airFMSysOutputEntry 3 }
|
|
|
|
-- airFM System Output Alarm Mapping
|
|
|
|
airFMSysAlarmMapSysTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMSysAlarmMapSysTable. "
|
|
::= { airFMSysAlarmMapSys 1 }
|
|
|
|
airFMSysAlarmMapSysTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMSysAlarmMapSysEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting alarm map information."
|
|
::= { airFMSysAlarmMapSys 2 }
|
|
|
|
airFMSysAlarmMapSysEntry OBJECT-TYPE
|
|
SYNTAX AirFMSysAlarmMapSysEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system alarm map type to reference."
|
|
INDEX { airFMSysAlarmMapSysOutputIndex }
|
|
::= { airFMSysAlarmMapSysTable 1 }
|
|
|
|
AirFMSysAlarmMapSysEntry ::=
|
|
SEQUENCE {
|
|
airFMSysAlarmMapSysOutputIndex INTEGER,
|
|
airFMSysAlarmMapSysAnyAlarm INTEGER,
|
|
airFMSysAlarmMapSystemOn INTEGER,
|
|
airFMSysAlarmMapSystemOffline INTEGER,
|
|
airFMSysAlarmMapSysHighEnvTemp INTEGER,
|
|
airFMSysAlarmMapSysLowEnvTemp INTEGER,
|
|
airFMSysAlarmMapSysHighEnvHum INTEGER,
|
|
airFMSysAlarmMapSysLowEnvHum INTEGER,
|
|
airFMSysAlarmMapSysFireDet INTEGER,
|
|
airFMSysAlarmMapSysSmokeDet INTEGER,
|
|
airFMSysAlarmMapSysEconIsol INTEGER,
|
|
airFMSysAlarmMapSysSupplySensFail INTEGER,
|
|
airFMSysAlarmMapSysReturnSensFail INTEGER,
|
|
airFMSysAlarmMapSysRemSensRemoved INTEGER,
|
|
airFMSysAlarmMapSysPrimSensFail INTEGER,
|
|
airFMSysAlarmMapSysSecSensFail INTEGER,
|
|
airFMSysAlarmMapSysSecSensActive INTEGER
|
|
}
|
|
|
|
airFMSysAlarmMapSysOutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the output relay."
|
|
::= { airFMSysAlarmMapSysEntry 1 }
|
|
|
|
airFMSysAlarmMapSysAnyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Any Alarm.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 2 }
|
|
|
|
airFMSysAlarmMapSystemOn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for System On.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 3 }
|
|
|
|
airFMSysAlarmMapSystemOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for System Offline.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 4 }
|
|
|
|
airFMSysAlarmMapSysHighEnvTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for High Environmental
|
|
Temperature.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 5 }
|
|
|
|
airFMSysAlarmMapSysLowEnvTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Low Environmental
|
|
Temperature.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 6 }
|
|
|
|
airFMSysAlarmMapSysHighEnvHum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for High Environmental
|
|
Humidity.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 7 }
|
|
|
|
airFMSysAlarmMapSysLowEnvHum OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Low Environmental
|
|
Humidity.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 8 }
|
|
|
|
airFMSysAlarmMapSysFireDet OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Fire Detected.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 9 }
|
|
|
|
airFMSysAlarmMapSysSmokeDet OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Smoke Detected.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 10 }
|
|
|
|
airFMSysAlarmMapSysEconIsol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Econ Isolator.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 11 }
|
|
|
|
airFMSysAlarmMapSysSupplySensFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Supply Sensor Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 12 }
|
|
|
|
airFMSysAlarmMapSysReturnSensFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Return Sensor Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 13 }
|
|
|
|
airFMSysAlarmMapSysRemSensRemoved OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Remote Sensor Removed.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 14 }
|
|
|
|
airFMSysAlarmMapSysPrimSensFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Primary Sensor Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 15 }
|
|
|
|
airFMSysAlarmMapSysSecSensFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Secondary Sensor Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 16 }
|
|
|
|
airFMSysAlarmMapSysSecSensActive OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System alarm map setting for Secondary Sensor Active.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapSysEntry 17 }
|
|
|
|
-- airFM Main Module Output Alarm Mapping
|
|
|
|
airFMSysAlarmMapMainModTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMSysAlarmMapMainModTable. "
|
|
::= { airFMSysAlarmMapMainMod 1 }
|
|
|
|
airFMSysAlarmMapMainModTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMSysAlarmMapMainModEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting alarm map information."
|
|
::= { airFMSysAlarmMapMainMod 2 }
|
|
|
|
airFMSysAlarmMapMainModEntry OBJECT-TYPE
|
|
SYNTAX AirFMSysAlarmMapMainModEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The main module alarm map type to reference."
|
|
INDEX { airFMSysAlarmMapMainModOutputIndex }
|
|
::= { airFMSysAlarmMapMainModTable 1 }
|
|
|
|
AirFMSysAlarmMapMainModEntry ::=
|
|
SEQUENCE {
|
|
airFMSysAlarmMapMainModOutputIndex INTEGER,
|
|
airFMSysAlarmMapMainModAnyAlarm INTEGER,
|
|
airFMSysAlarmMapMainModMaintReq INTEGER,
|
|
airFMSysAlarmMapMainModCoolFail INTEGER,
|
|
airFMSysAlarmMapMainModHighSupplyTemp INTEGER,
|
|
airFMSysAlarmMapMainModLowSupplyTemp INTEGER,
|
|
airFMSysAlarmMapMainModHumFail INTEGER,
|
|
airFMSysAlarmMapMainModHumReplCyl INTEGER,
|
|
airFMSysAlarmMapMainModCondPumpFail INTEGER,
|
|
airFMSysAlarmMapMainModBlwrCntl1Fail INTEGER,
|
|
airFMSysAlarmMapMainModBlwrCntl2Fail INTEGER,
|
|
airFMSysAlarmMapMainModHighFltrDP INTEGER,
|
|
airFMSysAlarmMapMainModLowAirFlow INTEGER,
|
|
airFMSysAlarmMapMainModAirBlckIntOpen INTEGER,
|
|
airFMSysAlarmMapMainModWaterDetected INTEGER
|
|
}
|
|
|
|
airFMSysAlarmMapMainModOutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the output relay."
|
|
::= { airFMSysAlarmMapMainModEntry 1 }
|
|
|
|
airFMSysAlarmMapMainModAnyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Any Alarm.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 2 }
|
|
|
|
airFMSysAlarmMapMainModMaintReq OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Module Maintenance
|
|
Required.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 3 }
|
|
|
|
airFMSysAlarmMapMainModCoolFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Module Cooling
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 4 }
|
|
|
|
airFMSysAlarmMapMainModHighSupplyTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for High Supply
|
|
Temperature.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 5 }
|
|
|
|
airFMSysAlarmMapMainModLowSupplyTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Low Supply
|
|
Temperature.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 6 }
|
|
|
|
airFMSysAlarmMapMainModHumFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Humidifier Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 7 }
|
|
|
|
airFMSysAlarmMapMainModHumReplCyl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Humidifier Replace
|
|
Cylinder.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 8 }
|
|
|
|
airFMSysAlarmMapMainModCondPumpFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Condensate Pump
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 9 }
|
|
|
|
airFMSysAlarmMapMainModBlwrCntl1Fail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Blower Controller 1
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 10 }
|
|
|
|
airFMSysAlarmMapMainModBlwrCntl2Fail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Blower Controller 2
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 11 }
|
|
|
|
airFMSysAlarmMapMainModHighFltrDP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for High Filter
|
|
Differential Pressure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 12 }
|
|
|
|
airFMSysAlarmMapMainModLowAirFlow OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Low Air Flow.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 13 }
|
|
|
|
airFMSysAlarmMapMainModAirBlckIntOpen OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Air Block Interlock
|
|
Open.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 14 }
|
|
|
|
airFMSysAlarmMapMainModWaterDetected OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Main Module alarm map setting for Water Detected.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapMainModEntry 15 }
|
|
|
|
-- airFM Exp Module 1 Output Alarm Mapping
|
|
|
|
airFMSysAlarmMapExpMod1TableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMSysAlarmMapExpMod1Table. "
|
|
::= { airFMSysAlarmMapExpMod1 1 }
|
|
|
|
airFMSysAlarmMapExpMod1Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMSysAlarmMapExpMod1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting alarm map information."
|
|
::= { airFMSysAlarmMapExpMod1 2 }
|
|
|
|
airFMSysAlarmMapExpMod1Entry OBJECT-TYPE
|
|
SYNTAX AirFMSysAlarmMapExpMod1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The expansion module 1 alarm map type to reference."
|
|
INDEX { airFMSysAlarmMapExpMod1OutputIndex }
|
|
::= { airFMSysAlarmMapExpMod1Table 1 }
|
|
|
|
AirFMSysAlarmMapExpMod1Entry ::=
|
|
SEQUENCE {
|
|
airFMSysAlarmMapExpMod1OutputIndex INTEGER,
|
|
airFMSysAlarmMapExpMod1AnyAlarm INTEGER,
|
|
airFMSysAlarmMapExpMod1MaintReq INTEGER,
|
|
airFMSysAlarmMapExpMod1CoolFail INTEGER,
|
|
airFMSysAlarmMapExpMod1HighSupplyTemp INTEGER,
|
|
airFMSysAlarmMapExpMod1LowSupplyTemp INTEGER,
|
|
airFMSysAlarmMapExpMod1HumFail INTEGER,
|
|
airFMSysAlarmMapExpMod1HumReplCyl INTEGER,
|
|
airFMSysAlarmMapExpMod1CondPumpFail INTEGER,
|
|
airFMSysAlarmMapExpMod1BlwrCntl1Fail INTEGER,
|
|
airFMSysAlarmMapExpMod1BlwrCntl2Fail INTEGER,
|
|
airFMSysAlarmMapExpMod1HighFltrDP INTEGER,
|
|
airFMSysAlarmMapExpMod1LowAirFlow INTEGER,
|
|
airFMSysAlarmMapExpMod1AirBlckIntOpen INTEGER,
|
|
airFMSysAlarmMapExpMod1WaterDetected INTEGER
|
|
}
|
|
|
|
airFMSysAlarmMapExpMod1OutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the output relay."
|
|
::= { airFMSysAlarmMapExpMod1Entry 1 }
|
|
|
|
airFMSysAlarmMapExpMod1AnyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Any Alarm.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 2 }
|
|
|
|
airFMSysAlarmMapExpMod1MaintReq OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Module Maintenance
|
|
Required.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 3 }
|
|
|
|
airFMSysAlarmMapExpMod1CoolFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Module Cooling
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 4 }
|
|
|
|
airFMSysAlarmMapExpMod1HighSupplyTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for High Supply
|
|
Temperature.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 5 }
|
|
|
|
airFMSysAlarmMapExpMod1LowSupplyTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Low Supply
|
|
Temperature.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 6 }
|
|
|
|
airFMSysAlarmMapExpMod1HumFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Humidifier Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 7 }
|
|
|
|
airFMSysAlarmMapExpMod1HumReplCyl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Humidifier Replace
|
|
Cylinder.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 8 }
|
|
|
|
airFMSysAlarmMapExpMod1CondPumpFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Condensate Pump
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 9 }
|
|
|
|
airFMSysAlarmMapExpMod1BlwrCntl1Fail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Blower Controller 1
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 10 }
|
|
|
|
airFMSysAlarmMapExpMod1BlwrCntl2Fail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Blower Controller 2
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 11 }
|
|
|
|
airFMSysAlarmMapExpMod1HighFltrDP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for High Filter
|
|
Differential Pressure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 12 }
|
|
|
|
airFMSysAlarmMapExpMod1LowAirFlow OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Low Air Flow.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 13 }
|
|
|
|
airFMSysAlarmMapExpMod1AirBlckIntOpen OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Air Block Interlock
|
|
Open.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 14 }
|
|
|
|
airFMSysAlarmMapExpMod1WaterDetected OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 1 alarm map setting for Water Detected.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod1Entry 15 }
|
|
|
|
-- airFM Expansion Module 2 Output Alarm Mapping
|
|
|
|
airFMSysAlarmMapExpMod2TableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the
|
|
airFMSysAlarmMapExpMod2Table."
|
|
::= { airFMSysAlarmMapExpMod2 1 }
|
|
|
|
airFMSysAlarmMapExpMod2Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMSysAlarmMapExpMod2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting alarm map information."
|
|
::= { airFMSysAlarmMapExpMod2 2 }
|
|
|
|
airFMSysAlarmMapExpMod2Entry OBJECT-TYPE
|
|
SYNTAX AirFMSysAlarmMapExpMod2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The expansion module 2 alarm map type to reference."
|
|
INDEX { airFMSysAlarmMapExpMod2OutputIndex }
|
|
::= { airFMSysAlarmMapExpMod2Table 1 }
|
|
|
|
AirFMSysAlarmMapExpMod2Entry ::=
|
|
SEQUENCE {
|
|
airFMSysAlarmMapExpMod2OutputIndex INTEGER,
|
|
airFMSysAlarmMapExpMod2AnyAlarm INTEGER,
|
|
airFMSysAlarmMapExpMod2MaintReq INTEGER,
|
|
airFMSysAlarmMapExpMod2CoolFail INTEGER,
|
|
airFMSysAlarmMapExpMod2HighSupplyTemp INTEGER,
|
|
airFMSysAlarmMapExpMod2LowSupplyTemp INTEGER,
|
|
airFMSysAlarmMapExpMod2HumFail INTEGER,
|
|
airFMSysAlarmMapExpMod2HumReplCyl INTEGER,
|
|
airFMSysAlarmMapExpMod2CondPumpFail INTEGER,
|
|
airFMSysAlarmMapExpMod2BlwrCntl1Fail INTEGER,
|
|
airFMSysAlarmMapExpMod2BlwrCntl2Fail INTEGER,
|
|
airFMSysAlarmMapExpMod2HighFltrDP INTEGER,
|
|
airFMSysAlarmMapExpMod2LowAirFlow INTEGER,
|
|
airFMSysAlarmMapExpMod2AirBlckIntOpen INTEGER,
|
|
airFMSysAlarmMapExpMod2WaterDetected INTEGER
|
|
}
|
|
|
|
airFMSysAlarmMapExpMod2OutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the output relay."
|
|
::= { airFMSysAlarmMapExpMod2Entry 1 }
|
|
|
|
airFMSysAlarmMapExpMod2AnyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Any Alarm.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 2 }
|
|
|
|
airFMSysAlarmMapExpMod2MaintReq OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Module Maintenance
|
|
Required.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 3 }
|
|
|
|
airFMSysAlarmMapExpMod2CoolFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Module Cooling
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 4 }
|
|
|
|
airFMSysAlarmMapExpMod2HighSupplyTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for High Supply
|
|
Temperature.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 5 }
|
|
|
|
airFMSysAlarmMapExpMod2LowSupplyTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Low Supply
|
|
Temperature.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 6 }
|
|
|
|
airFMSysAlarmMapExpMod2HumFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Humidifier Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 7 }
|
|
|
|
airFMSysAlarmMapExpMod2HumReplCyl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Humidifier Replace
|
|
Cylinder.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 8 }
|
|
|
|
airFMSysAlarmMapExpMod2CondPumpFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Condensate Pump
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 9 }
|
|
|
|
airFMSysAlarmMapExpMod2BlwrCntl1Fail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Blower Controller 1
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 10 }
|
|
|
|
airFMSysAlarmMapExpMod2BlwrCntl2Fail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Blower Controller 2
|
|
Failure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 11 }
|
|
|
|
airFMSysAlarmMapExpMod2HighFltrDP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for High Filter
|
|
Differential Pressure.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 12 }
|
|
|
|
airFMSysAlarmMapExpMod2LowAirFlow OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Low Air Flow.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 13 }
|
|
|
|
airFMSysAlarmMapExpMod2AirBlckIntOpen OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Air Block Interlock
|
|
Open.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 14 }
|
|
|
|
airFMSysAlarmMapExpMod2WaterDetected OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Exp Module 2 alarm map setting for Water Detected.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapExpMod2Entry 15 }
|
|
|
|
-- airFM Input Alarm Mapping
|
|
|
|
airFMSysAlarmMapInputTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMSysAlarmMapInputTable. "
|
|
::= { airFMSysAlarmMapInput 1 }
|
|
|
|
airFMSysAlarmMapInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMSysAlarmMapInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting alarm map information."
|
|
::= { airFMSysAlarmMapInput 2 }
|
|
|
|
airFMSysAlarmMapInputEntry OBJECT-TYPE
|
|
SYNTAX AirFMSysAlarmMapInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input contact alarm map type to reference."
|
|
INDEX { airFMSysAlarmMapInputOutputIndex }
|
|
::= { airFMSysAlarmMapInputTable 1 }
|
|
|
|
AirFMSysAlarmMapInputEntry ::=
|
|
SEQUENCE {
|
|
airFMSysAlarmMapInputOutputIndex INTEGER,
|
|
airFMSysAlarmMapInput1 INTEGER,
|
|
airFMSysAlarmMapInput2 INTEGER,
|
|
airFMSysAlarmMapInput3 INTEGER,
|
|
airFMSysAlarmMapInput4 INTEGER,
|
|
airFMSysAlarmMapInput5 INTEGER,
|
|
airFMSysAlarmMapInput6 INTEGER,
|
|
airFMSysAlarmMapInput7 INTEGER,
|
|
airFMSysAlarmMapInput8 INTEGER,
|
|
airFMSysAlarmMapInput9 INTEGER,
|
|
airFMSysAlarmMapInput10 INTEGER,
|
|
airFMSysAlarmMapInput11 INTEGER,
|
|
airFMSysAlarmMapInput12 INTEGER,
|
|
airFMSysAlarmMapInput13 INTEGER,
|
|
airFMSysAlarmMapInput14 INTEGER,
|
|
airFMSysAlarmMapInput15 INTEGER,
|
|
airFMSysAlarmMapInput16 INTEGER
|
|
}
|
|
|
|
airFMSysAlarmMapInputOutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the output relay."
|
|
::= { airFMSysAlarmMapInputEntry 1 }
|
|
|
|
airFMSysAlarmMapInput1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 1 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 2 }
|
|
|
|
airFMSysAlarmMapInput2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 2 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 3 }
|
|
|
|
airFMSysAlarmMapInput3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 3 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 4 }
|
|
|
|
airFMSysAlarmMapInput4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 4 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 5 }
|
|
|
|
airFMSysAlarmMapInput5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 5 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 6 }
|
|
|
|
airFMSysAlarmMapInput6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 6 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 7 }
|
|
|
|
airFMSysAlarmMapInput7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 7 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 8 }
|
|
|
|
airFMSysAlarmMapInput8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 8 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 9 }
|
|
|
|
airFMSysAlarmMapInput9 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 9 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 10 }
|
|
|
|
airFMSysAlarmMapInput10 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 10 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 11 }
|
|
|
|
airFMSysAlarmMapInput11 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 11 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 12 }
|
|
|
|
airFMSysAlarmMapInput12 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 12 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 13 }
|
|
|
|
airFMSysAlarmMapInput13 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 13 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 14 }
|
|
|
|
airFMSysAlarmMapInput14 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 14 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 15 }
|
|
|
|
airFMSysAlarmMapInput15 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 15 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 16 }
|
|
|
|
airFMSysAlarmMapInput16 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input contact 16 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapInputEntry 17 }
|
|
|
|
-- airFM Output Alarm Mapping
|
|
|
|
airFMSysAlarmMapOutputTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the
|
|
airFMSysAlarmMapOutputTable. "
|
|
::= { airFMSysAlarmMapOutput 1 }
|
|
|
|
airFMSysAlarmMapOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMSysAlarmMapOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting alarm map information."
|
|
::= { airFMSysAlarmMapOutput 2 }
|
|
|
|
airFMSysAlarmMapOutputEntry OBJECT-TYPE
|
|
SYNTAX AirFMSysAlarmMapOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input contact alarm map type to reference."
|
|
INDEX { airFMSysAlarmMapOutputIndex }
|
|
::= { airFMSysAlarmMapOutputTable 1 }
|
|
|
|
AirFMSysAlarmMapOutputEntry ::=
|
|
SEQUENCE {
|
|
airFMSysAlarmMapOutputIndex INTEGER,
|
|
airFMSysAlarmMapOutput1 INTEGER,
|
|
airFMSysAlarmMapOutput2 INTEGER,
|
|
airFMSysAlarmMapOutput3 INTEGER,
|
|
airFMSysAlarmMapOutput4 INTEGER,
|
|
airFMSysAlarmMapOutput5 INTEGER,
|
|
airFMSysAlarmMapOutput6 INTEGER,
|
|
airFMSysAlarmMapOutput7 INTEGER,
|
|
airFMSysAlarmMapOutput8 INTEGER,
|
|
airFMSysAlarmMapOutput9 INTEGER,
|
|
airFMSysAlarmMapOutput10 INTEGER,
|
|
airFMSysAlarmMapOutput11 INTEGER,
|
|
airFMSysAlarmMapOutput12 INTEGER,
|
|
airFMSysAlarmMapOutput13 INTEGER,
|
|
airFMSysAlarmMapOutput14 INTEGER,
|
|
airFMSysAlarmMapOutput15 INTEGER,
|
|
airFMSysAlarmMapOutput16 INTEGER
|
|
}
|
|
|
|
airFMSysAlarmMapOutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the output relay."
|
|
::= { airFMSysAlarmMapOutputEntry 1 }
|
|
|
|
airFMSysAlarmMapOutput1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 1 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 2 }
|
|
|
|
airFMSysAlarmMapOutput2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 2 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 3 }
|
|
|
|
airFMSysAlarmMapOutput3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 3 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 4 }
|
|
|
|
airFMSysAlarmMapOutput4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 4 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 5 }
|
|
|
|
airFMSysAlarmMapOutput5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 5 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 6 }
|
|
|
|
airFMSysAlarmMapOutput6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 6 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 7 }
|
|
|
|
airFMSysAlarmMapOutput7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 7 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 8 }
|
|
|
|
airFMSysAlarmMapOutput8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 8 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 9 }
|
|
|
|
airFMSysAlarmMapOutput9 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 9 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 10 }
|
|
|
|
airFMSysAlarmMapOutput10 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 10 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 11 }
|
|
|
|
airFMSysAlarmMapOutput11 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 11 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 12 }
|
|
|
|
airFMSysAlarmMapOutput12 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 12 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 13 }
|
|
|
|
airFMSysAlarmMapOutput13 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 13 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 14 }
|
|
|
|
airFMSysAlarmMapOutput14 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 14 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 15 }
|
|
|
|
airFMSysAlarmMapOutput15 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 15 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 16 }
|
|
|
|
airFMSysAlarmMapOutput16 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output relay 16 alarm map setting.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMSysAlarmMapOutputEntry 17 }
|
|
|
|
-- airFM Module Identification Table
|
|
|
|
airFMModIdentTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMModIdentTable. "
|
|
::= { airFMModIdent 1 }
|
|
|
|
airFMModIdentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMModIdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each module in
|
|
the system. "
|
|
::= { airFMModIdent 2 }
|
|
|
|
airFMModIdentEntry OBJECT-TYPE
|
|
SYNTAX AirFMModIdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module to get information from."
|
|
INDEX { airFMModIdentModuleIndex }
|
|
::= { airFMModIdentTable 1 }
|
|
|
|
AirFMModIdentEntry ::=
|
|
SEQUENCE {
|
|
airFMModIdentModuleIndex INTEGER,
|
|
airFMModModelNumber DisplayString,
|
|
airFMModSerialNumber DisplayString,
|
|
airFMModManufactureDate DisplayString,
|
|
airFMModFirmwareRev DisplayString,
|
|
airFMModHardwareRev DisplayString
|
|
}
|
|
|
|
airFMModIdentModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the module."
|
|
::= { airFMModIdentEntry 1 }
|
|
|
|
airFMModModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Model number of the Module."
|
|
::= { airFMModIdentEntry 2 }
|
|
|
|
airFMModSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unique identification number for this Module."
|
|
::= { airFMModIdentEntry 3 }
|
|
|
|
airFMModManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date the Module was manufactured."
|
|
::= { airFMModIdentEntry 4 }
|
|
|
|
airFMModFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Revision number of the firmware installed on this
|
|
Module."
|
|
::= { airFMModIdentEntry 5 }
|
|
|
|
airFMModHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Revision number of the hardware installed on this
|
|
Module."
|
|
::= { airFMModIdentEntry 6 }
|
|
|
|
-- airFM Module Status Table
|
|
|
|
airFMModStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMModStatusTable. "
|
|
::= { airFMModStatus 1 }
|
|
|
|
airFMModStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMModStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each module in
|
|
the system. "
|
|
::= { airFMModStatus 2 }
|
|
|
|
airFMModStatusEntry OBJECT-TYPE
|
|
SYNTAX AirFMModStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module to get information from."
|
|
INDEX { airFMModStatusModuleIndex }
|
|
::= { airFMModStatusTable 1 }
|
|
|
|
AirFMModStatusEntry ::=
|
|
SEQUENCE {
|
|
airFMModStatusModuleIndex INTEGER,
|
|
airFMModSupplyTempC INTEGER,
|
|
airFMModSupplyTempF INTEGER,
|
|
airFMModSupplyHum INTEGER,
|
|
airFMModReturnTempC INTEGER,
|
|
airFMModReturnTempF INTEGER,
|
|
airFMModReturnHum INTEGER,
|
|
airFMModFilterDiffPresPa INTEGER,
|
|
airFMModFilterDiffPresInWC INTEGER,
|
|
airFMModCoilDiffPresPa INTEGER,
|
|
airFMModCoilDiffPresInWC INTEGER
|
|
}
|
|
|
|
airFMModStatusModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the module."
|
|
::= { airFMModStatusEntry 1 }
|
|
|
|
airFMModSupplyTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature measured at the supply sensor.
|
|
Measured in tenths of degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModStatusEntry 2 }
|
|
|
|
airFMModSupplyTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature measured at the supply sensor.
|
|
Measured in tenths of degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModStatusEntry 3 }
|
|
|
|
airFMModSupplyHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidity measured at the supply sensor.
|
|
Measured in tenths of percent relative humidity.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModStatusEntry 4 }
|
|
|
|
airFMModReturnTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature measured at the return sensor.
|
|
Measured in tenths of degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModStatusEntry 5 }
|
|
|
|
airFMModReturnTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature measured at the return sensor.
|
|
Measured in tenths of degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModStatusEntry 6 }
|
|
|
|
airFMModReturnHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidity measured at the return sensor.
|
|
Measured in tenths of percent relative humidity.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModStatusEntry 7 }
|
|
|
|
airFMModFilterDiffPresPa OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The difference in pressure on either side of the air
|
|
filters. A high differential pressure indicates a
|
|
clogged filter. Measured in Pascals.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModStatusEntry 8 }
|
|
|
|
airFMModFilterDiffPresInWC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The difference in pressure on either side of the air
|
|
filters. A high differential pressure indicates a
|
|
clogged filter. Measured in hundredths of inches
|
|
water column.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModStatusEntry 9 }
|
|
|
|
airFMModCoilDiffPresPa OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The difference in pressure on either side of the
|
|
cooling/dehumidification coils. Measured in Pascals.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModStatusEntry 10 }
|
|
|
|
airFMModCoilDiffPresInWC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The difference in pressure on either side of the
|
|
cooling/dehumidification coils. Measured in
|
|
hundredths of inches water column.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModStatusEntry 11 }
|
|
|
|
-- airFM Module Properties Table
|
|
|
|
airFMModPropTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMModPropTable. "
|
|
::= { airFMModProperties 1 }
|
|
|
|
airFMModPropTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMModPropEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each module in
|
|
the system. "
|
|
::= { airFMModProperties 2 }
|
|
|
|
airFMModPropEntry OBJECT-TYPE
|
|
SYNTAX AirFMModPropEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module to get information from."
|
|
INDEX { airFMModPropModuleIndex }
|
|
::= { airFMModPropTable 1 }
|
|
|
|
AirFMModPropEntry ::=
|
|
SEQUENCE {
|
|
airFMModPropModuleIndex INTEGER,
|
|
airFMModOutputCapacity INTEGER,
|
|
airFMModCapacityCtrl INTEGER,
|
|
airFMModHeaterType INTEGER,
|
|
airFMModElectricHeaterType INTEGER,
|
|
airFMModHumidifierType INTEGER,
|
|
airFMModBlwrFreqSetting INTEGER,
|
|
airFMModNomCoilDiffPresPa INTEGER,
|
|
airFMModNomCoilDiffPresInWC INTEGER,
|
|
airFMModCondPump INTEGER,
|
|
airFMModFireDetector INTEGER,
|
|
airFMModSmokeDetector INTEGER,
|
|
airFMModWaterDetector INTEGER
|
|
}
|
|
|
|
airFMModPropModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the module."
|
|
::= { airFMModPropEntry 1 }
|
|
|
|
airFMModOutputCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
kw45 (2),
|
|
kw35 (3),
|
|
kw40 (4),
|
|
kw50 (5),
|
|
kw80 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cooling capacity (in Kilowatts) of the displayed
|
|
Module.
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 2 }
|
|
|
|
airFMModCapacityCtrl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
tandem (2),
|
|
hotGasBypass (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The method used to load and unload the compressors.
|
|
Tandem compressor Modules use two stages (one
|
|
compressor each). Single compressor Modules use hot
|
|
gas bypass.
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 3 }
|
|
|
|
airFMModHeaterType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
none (2),
|
|
electricSCR (3),
|
|
steam (4),
|
|
hotWaterOnOff (5),
|
|
hotGasReheat (6),
|
|
hotGasAndElectric (7),
|
|
hotWaterProp (8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of reheating device installed in this Module.
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 4 }
|
|
|
|
airFMModElectricHeaterType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
kw10 (2),
|
|
kw15 (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type/capacity of the electric heater, if installed.
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 5 }
|
|
|
|
airFMModHumidifierType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
none (2),
|
|
steamElectrode (3),
|
|
liveSteam (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of equipment installed in the Module to run
|
|
the humidification mode.
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 6 }
|
|
|
|
airFMModBlwrFreqSetting OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Frequency of the blower in tenths of hertz.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 7 }
|
|
|
|
airFMModNomCoilDiffPresPa OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The difference in pressure on either side of the
|
|
cooling/dehumidification coils. Measured in Pascals.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 8 }
|
|
|
|
airFMModNomCoilDiffPresInWC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The difference in pressure on either side of the
|
|
cooling/dehumidification coils. Measured in
|
|
hundredths of inches water column.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 9 }
|
|
|
|
airFMModCondPump OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
notPresent (2),
|
|
present (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the presence of a condensate pump in the
|
|
Modules of this System.
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 10 }
|
|
|
|
airFMModFireDetector OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
notPresent (2),
|
|
present (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the presence of a fire detector for each
|
|
of the Modules in this System.
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 11 }
|
|
|
|
airFMModSmokeDetector OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
notPresent (2),
|
|
present (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the presence of a smoke detector for each
|
|
of the Modules in this System.
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 12 }
|
|
|
|
airFMModWaterDetector OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
notPresent (2),
|
|
present (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the presence of a water leak detector for
|
|
each of the Modules in this System.
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModPropEntry 13 }
|
|
|
|
-- airFM Module Cooling Table
|
|
|
|
airFMModCoolTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMModCoolTable. "
|
|
::= { airFMModCooling 1 }
|
|
|
|
airFMModCoolTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMModCoolEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each module in
|
|
the system. "
|
|
::= { airFMModCooling 2 }
|
|
|
|
airFMModCoolEntry OBJECT-TYPE
|
|
SYNTAX AirFMModCoolEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module to get information from."
|
|
INDEX { airFMModCoolModuleIndex }
|
|
::= { airFMModCoolTable 1 }
|
|
|
|
AirFMModCoolEntry ::=
|
|
SEQUENCE {
|
|
airFMModCoolModuleIndex INTEGER,
|
|
airFMModComp1 INTEGER,
|
|
airFMModComp2 INTEGER,
|
|
airFMModSuctPresKPa INTEGER,
|
|
airFMModSuctPresPSI INTEGER,
|
|
airFMModDischPresKPa INTEGER,
|
|
airFMModDischPresPSI INTEGER,
|
|
airFMModCondFluidVlvPos INTEGER,
|
|
airFMModCoilFluidVlvPos INTEGER
|
|
}
|
|
|
|
airFMModCoolModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the module."
|
|
::= { airFMModCoolEntry 1 }
|
|
|
|
airFMModComp1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
on (2),
|
|
off (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of compressor 1 of the tandem compressor
|
|
unit (on or off).
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModCoolEntry 2 }
|
|
|
|
airFMModComp2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
on (2),
|
|
off (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of compressor 2 of the tandem compressor
|
|
unit (on or off).
|
|
A value of notApplicable indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModCoolEntry 3 }
|
|
|
|
airFMModSuctPresKPa OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The refrigerant pressure measured at the suction
|
|
inlet of the compressor. Measured in kiloPascals.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModCoolEntry 4 }
|
|
|
|
airFMModSuctPresPSI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The refrigerant pressure measured at the suction
|
|
inlet of the compressor. Measured in pounds per
|
|
square inch.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModCoolEntry 5 }
|
|
|
|
airFMModDischPresKPa OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The refrigerant pressure measured at the discharge
|
|
outlet of the compressor. Measured in kiloPascals.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModCoolEntry 6 }
|
|
|
|
airFMModDischPresPSI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The refrigerant pressure measured at the discharge
|
|
outlet of the compressor. Measured in pounds per
|
|
square inch.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModCoolEntry 7 }
|
|
|
|
airFMModCondFluidVlvPos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The position of the condenser fluid valve. The valve
|
|
regulates the flow of liquid coolant into the heat
|
|
exchanger (condenser). 100% indicates the valve is
|
|
completely open, and 0% indicates that the valve is
|
|
closed. Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModCoolEntry 8 }
|
|
|
|
airFMModCoilFluidVlvPos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The position of the coil fluid valve. The valve
|
|
regulates the flow of liquid coolant in the fluid
|
|
cooling coil (MultiCool, Economizer, or Chilled
|
|
Water). 100% indicates the valve is completely open,
|
|
and 0% indicates that the valve is closed. Measured
|
|
in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModCoolEntry 9 }
|
|
|
|
|
|
-- airFM Module Humidity Control Table
|
|
|
|
airFMModHumTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMModHumTable. "
|
|
::= { airFMModHumidity 1 }
|
|
|
|
airFMModHumTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMModHumEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each module in
|
|
the system. "
|
|
::= { airFMModHumidity 2 }
|
|
|
|
airFMModHumEntry OBJECT-TYPE
|
|
SYNTAX AirFMModHumEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module to get information from."
|
|
INDEX { airFMModHumModuleIndex }
|
|
::= { airFMModHumTable 1 }
|
|
|
|
AirFMModHumEntry ::=
|
|
SEQUENCE {
|
|
airFMModHumModuleIndex INTEGER,
|
|
airFMModHumidifier INTEGER,
|
|
airFMModElectrodeCurrent INTEGER,
|
|
airFMModHumActualOutput INTEGER,
|
|
airFMModWaterConductivity INTEGER,
|
|
airFMModHotWaterVlvPos INTEGER,
|
|
airFMModStmElectHumMode INTEGER
|
|
}
|
|
|
|
airFMModHumModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the module."
|
|
::= { airFMModHumEntry 1 }
|
|
|
|
airFMModHumidifier OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
none (2),
|
|
steamElectrode (3),
|
|
liveSteam (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of equipment installed in the Module to run
|
|
the humidification mode.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModHumEntry 2 }
|
|
|
|
airFMModElectrodeCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current drawn by the electrodes of the steam
|
|
cylinder humidifier. Measured in tenths of amps.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModHumEntry 3 }
|
|
|
|
airFMModHumActualOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidification output of an individual Module.
|
|
Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModHumEntry 4 }
|
|
|
|
airFMModWaterConductivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The conductivity of the water in the humidifier
|
|
cylinder. Measured in microSiemens per centimeter.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModHumEntry 5 }
|
|
|
|
airFMModHotWaterVlvPos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The position of the hot water valve. 100% indicates
|
|
the valve is completely open, and 0% indicates that
|
|
the valve is closed. Measured in percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModHumEntry 6 }
|
|
|
|
airFMModStmElectHumMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
off (2),
|
|
auto (3),
|
|
drain (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the humidifier function mode.
|
|
Off: Remove power from electrodes.
|
|
Auto: Humidifier controlled by Module controller.
|
|
Drain: Remove power from electrodes and drain the cylinder.
|
|
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModHumEntry 7 }
|
|
|
|
-- airFM Module Blower 1 Table
|
|
|
|
airFMModBlwr1TableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMModBlwr1Table. "
|
|
::= { airFMModBlower1 1 }
|
|
|
|
airFMModBlwr1Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMModBlwr1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each module in
|
|
the system. "
|
|
::= { airFMModBlower1 2 }
|
|
|
|
airFMModBlwr1Entry OBJECT-TYPE
|
|
SYNTAX AirFMModBlwr1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module to get information from."
|
|
INDEX { airFMModBlwr1ModuleIndex }
|
|
::= { airFMModBlwr1Table 1 }
|
|
|
|
AirFMModBlwr1Entry ::=
|
|
SEQUENCE {
|
|
airFMModBlwr1ModuleIndex INTEGER,
|
|
airFMModBlwr1CtrlType INTEGER,
|
|
airFMModBlwr1CmdFreq INTEGER,
|
|
airFMModBlwr1ActFreq INTEGER,
|
|
airFMModBlwr1Poles INTEGER,
|
|
airFMModBlwr1RatedHorsePower INTEGER,
|
|
airFMModBlwr1RatedCurrent INTEGER,
|
|
airFMModBlwr1ActTorq INTEGER,
|
|
airFMModBlwr1Current INTEGER,
|
|
airFMModBlwr1Vlt INTEGER,
|
|
airFMModBlwr1DCLinkVlt INTEGER,
|
|
airFMModBlwr1AccTime INTEGER,
|
|
airFMModBlwr1DecTime INTEGER,
|
|
airFMModBlwr1CapLife INTEGER,
|
|
airFMModBlwr1CtrlCoolFanLife INTEGER,
|
|
airFMModBlwr1ElOvMode INTEGER,
|
|
airFMModBlwr1ElOvSetting INTEGER,
|
|
airFMModBlwr1ElOvTimeConst INTEGER,
|
|
airFMModBlwr1FanPower INTEGER,
|
|
airFMModBlwr1HeatsinkTempC INTEGER,
|
|
airFMModBlwr1HeatsinkTempF INTEGER,
|
|
airFMModBlwr1ChokeTempC INTEGER,
|
|
airFMModBlwr1ChokeTempF INTEGER,
|
|
airFMModBlwr1InverterTempC INTEGER,
|
|
airFMModBlwr1InverterTempF INTEGER
|
|
}
|
|
|
|
airFMModBlwr1ModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the module."
|
|
::= { airFMModBlwr1Entry 1 }
|
|
|
|
airFMModBlwr1CtrlType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
fujiVFD (2),
|
|
ecController (3),
|
|
danfossVFD (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of blower controller.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 2 }
|
|
|
|
airFMModBlwr1CmdFreq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The requested operating frequency for the blower.
|
|
Measured in tenths of hertz.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 3 }
|
|
|
|
airFMModBlwr1ActFreq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frequency at which the blower controller is
|
|
operating. Measured in tenths of hertz.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 4 }
|
|
|
|
airFMModBlwr1Poles OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of poles of the blower motor that the
|
|
blower controller is controlling.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 5 }
|
|
|
|
airFMModBlwr1RatedHorsePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power rating of the blower motor. Measured in
|
|
hundredths of horsepower.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 6 }
|
|
|
|
airFMModBlwr1RatedCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current rating of the blower motor. Measured in
|
|
hundredths of amps.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 7 }
|
|
|
|
airFMModBlwr1ActTorq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual torque of the blower motor. Measured in
|
|
hundredths of percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 8 }
|
|
|
|
airFMModBlwr1Current OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percent of rated current drawn by the blower
|
|
motor. Measured in hundredths of percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 9 }
|
|
|
|
airFMModBlwr1Vlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The voltage supplied to the blower motor. Measured
|
|
in tenths of volts RMS.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 10 }
|
|
|
|
airFMModBlwr1DCLinkVlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The voltage of the blower controller's DC bus.
|
|
Measured in volts DC.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 11 }
|
|
|
|
airFMModBlwr1AccTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time to accelerate the blower to the specified
|
|
frequency. Measured in tenths of seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 12 }
|
|
|
|
airFMModBlwr1DecTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time to decelerate the blower frequency to zero.
|
|
Measured in tenths of seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 13 }
|
|
|
|
airFMModBlwr1CapLife OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The remaining life of the main circuit capacitor.
|
|
Measured in tenths of percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 14 }
|
|
|
|
airFMModBlwr1CtrlCoolFanLife OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total operation time of the blower controller
|
|
cooling fan. Measured in hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 15 }
|
|
|
|
airFMModBlwr1ElOvMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
inactive (2),
|
|
active (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enables or disables the electronic overload relay.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 16 }
|
|
|
|
airFMModBlwr1ElOvSetting OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The electronic overload relay is activated when the
|
|
current exceeds this threshold. Measured in
|
|
hundredths of amps.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 17 }
|
|
|
|
airFMModBlwr1ElOvTimeConst OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay between the current exceeding the overload
|
|
threshold and the activation of the electronic
|
|
overload relay. Measured in tenths of minutes.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 18 }
|
|
|
|
airFMModBlwr1FanPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual power of the blower motor. Measured in
|
|
tenths of percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 19 }
|
|
|
|
airFMModBlwr1HeatsinkTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the heatsink on the blower
|
|
controller. Measured in degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 20 }
|
|
|
|
airFMModBlwr1HeatsinkTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the heatsink on the blower
|
|
controller. Measured in degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 21 }
|
|
|
|
airFMModBlwr1ChokeTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the choke on the blower
|
|
controller. Measured in degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 22 }
|
|
|
|
airFMModBlwr1ChokeTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the choke on the blower
|
|
controller. Measured in degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 23 }
|
|
|
|
airFMModBlwr1InverterTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the inverter on the blower
|
|
controller. Measured in degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 24 }
|
|
|
|
airFMModBlwr1InverterTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the inverter on the blower
|
|
controller. Measured in degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr1Entry 25 }
|
|
|
|
|
|
-- airFM Module Blower 2 Table
|
|
|
|
airFMModBlwr2TableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMModBlwr2Table. "
|
|
::= { airFMModBlower2 1 }
|
|
|
|
airFMModBlwr2Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMModBlwr2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each module in
|
|
the system. "
|
|
::= { airFMModBlower2 2 }
|
|
|
|
airFMModBlwr2Entry OBJECT-TYPE
|
|
SYNTAX AirFMModBlwr2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module to get information from."
|
|
INDEX { airFMModBlwr2ModuleIndex }
|
|
::= { airFMModBlwr2Table 1 }
|
|
|
|
AirFMModBlwr2Entry ::=
|
|
SEQUENCE {
|
|
airFMModBlwr2ModuleIndex INTEGER,
|
|
airFMModBlwr2CtrlType INTEGER,
|
|
airFMModBlwr2CmdFreq INTEGER,
|
|
airFMModBlwr2ActFreq INTEGER,
|
|
airFMModBlwr2Poles INTEGER,
|
|
airFMModBlwr2RatedHorsePower INTEGER,
|
|
airFMModBlwr2RatedCurrent INTEGER,
|
|
airFMModBlwr2ActTorq INTEGER,
|
|
airFMModBlwr2Current INTEGER,
|
|
airFMModBlwr2Vlt INTEGER,
|
|
airFMModBlwr2DCLinkVlt INTEGER,
|
|
airFMModBlwr2AccTime INTEGER,
|
|
airFMModBlwr2DecTime INTEGER,
|
|
airFMModBlwr2CapLife INTEGER,
|
|
airFMModBlwr2CtrlCoolFanLife INTEGER,
|
|
airFMModBlwr2ElOvMode INTEGER,
|
|
airFMModBlwr2ElOvSetting INTEGER,
|
|
airFMModBlwr2ElOvTimeConst INTEGER,
|
|
airFMModBlwr2FanPower INTEGER,
|
|
airFMModBlwr2HeatsinkTempC INTEGER,
|
|
airFMModBlwr2HeatsinkTempF INTEGER,
|
|
airFMModBlwr2ChokeTempC INTEGER,
|
|
airFMModBlwr2ChokeTempF INTEGER,
|
|
airFMModBlwr2InverterTempC INTEGER,
|
|
airFMModBlwr2InverterTempF INTEGER
|
|
}
|
|
|
|
airFMModBlwr2ModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the module."
|
|
::= { airFMModBlwr2Entry 1 }
|
|
|
|
airFMModBlwr2CtrlType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
fujiVFD (2),
|
|
ecController (3),
|
|
danfossVFD (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of blower controller.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 2 }
|
|
|
|
airFMModBlwr2CmdFreq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The requested operating frequency for the blower.
|
|
Measured in tenths of hertz.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 3 }
|
|
|
|
airFMModBlwr2ActFreq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frequency at which the blower controller is
|
|
operating. Measured in tenths of hertz.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 4 }
|
|
|
|
airFMModBlwr2Poles OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of poles of the blower motor that the
|
|
blower controller is controlling.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 5 }
|
|
|
|
airFMModBlwr2RatedHorsePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power rating of the blower motor. Measured in
|
|
hundredths of horsepower.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 6 }
|
|
|
|
airFMModBlwr2RatedCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current rating of the blower motor. Measured in
|
|
hundredths of amps.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 7 }
|
|
|
|
airFMModBlwr2ActTorq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual torque of the blower motor. Measured in
|
|
hundredths of percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 8 }
|
|
|
|
airFMModBlwr2Current OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percent of rated current drawn by the blower
|
|
motor. Measured in hundredths of percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 9 }
|
|
|
|
airFMModBlwr2Vlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The voltage supplied to the blower motor. Measured
|
|
in tenths of volts RMS.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 10 }
|
|
|
|
airFMModBlwr2DCLinkVlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The voltage of the blower controller's DC bus.
|
|
Measured in volts DC.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 11 }
|
|
|
|
airFMModBlwr2AccTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time to accelerate the blower to the specified
|
|
frequency. Measured in tenths of seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 12 }
|
|
|
|
airFMModBlwr2DecTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time to decelerate the blower frequency to zero.
|
|
Measured in tenths of seconds.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 13 }
|
|
|
|
airFMModBlwr2CapLife OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The remaining life of the main circuit capacitor.
|
|
Measured in tenths of percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 14 }
|
|
|
|
airFMModBlwr2CtrlCoolFanLife OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total operation time of the blower controller
|
|
cooling fan. Measured in hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 15 }
|
|
|
|
airFMModBlwr2ElOvMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
inactive (2),
|
|
active (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enables or disables the electronic overload relay.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 16 }
|
|
|
|
airFMModBlwr2ElOvSetting OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The electronic overload relay is activated when the
|
|
current exceeds this threshold. Measured in
|
|
hundredths of amps.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 17 }
|
|
|
|
airFMModBlwr2ElOvTimeConst OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay between the current exceeding the overload
|
|
threshold and the activation of the electronic
|
|
overload relay. Measured in tenths of minutes.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 18 }
|
|
|
|
airFMModBlwr2FanPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual power of the blower motor. Measured in
|
|
tenths of percent.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 19 }
|
|
|
|
airFMModBlwr2HeatsinkTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the heatsink on the blower
|
|
controller. Measured in degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 20 }
|
|
|
|
airFMModBlwr2HeatsinkTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the heatsink on the blower
|
|
controller. Measured in degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 21 }
|
|
|
|
airFMModBlwr2ChokeTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the choke on the blower
|
|
controller. Measured in degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 22 }
|
|
|
|
airFMModBlwr2ChokeTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the choke on the blower
|
|
controller. Measured in degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 23 }
|
|
|
|
airFMModBlwr2InverterTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the inverter on the blower
|
|
controller. Measured in degrees Celsius.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 24 }
|
|
|
|
airFMModBlwr2InverterTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the inverter on the blower
|
|
controller. Measured in degrees Fahrenheit.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModBlwr2Entry 25 }
|
|
|
|
-- airFM Module Run Hours Table
|
|
|
|
airFMModRHTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMModRHTable. "
|
|
::= { airFMModRunHours 1 }
|
|
|
|
airFMModRHTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMModRHEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each module in
|
|
the system. "
|
|
::= { airFMModRunHours 2 }
|
|
|
|
airFMModRHEntry OBJECT-TYPE
|
|
SYNTAX AirFMModRHEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module to get information from."
|
|
INDEX { airFMModRHModuleIndex }
|
|
::= { airFMModRHTable 1 }
|
|
|
|
AirFMModRHEntry ::=
|
|
SEQUENCE {
|
|
airFMModRHModuleIndex INTEGER,
|
|
airFMModRHComp1 INTEGER,
|
|
airFMModRHComp2 INTEGER,
|
|
airFMModRHHeater INTEGER,
|
|
airFMModRHHum INTEGER,
|
|
airFMModRHBlwr1 INTEGER,
|
|
airFMModRHBlwr2 INTEGER,
|
|
airFMModRHBlwrCtrl1 INTEGER,
|
|
airFMModRHBlwrCtrl2 INTEGER,
|
|
airFMModRHComp1Reset INTEGER,
|
|
airFMModRHComp2Reset INTEGER,
|
|
airFMModRHHeaterReset INTEGER,
|
|
airFMModRHHumReset INTEGER,
|
|
airFMModRHBlwr1Reset INTEGER,
|
|
airFMModRHBlwr2Reset INTEGER
|
|
}
|
|
|
|
airFMModRHModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the module."
|
|
::= { airFMModRHEntry 1 }
|
|
|
|
airFMModRHComp1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 run hours.
|
|
A value of -2147483648 indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 2 }
|
|
|
|
airFMModRHComp2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 run hours.
|
|
A value of -2147483648 indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 3 }
|
|
|
|
airFMModRHHeater OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Heater run hours.
|
|
A value of -2147483648 indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 4 }
|
|
|
|
airFMModRHHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier run hours
|
|
A value of -2147483648 indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 5 }
|
|
|
|
airFMModRHBlwr1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 1 run hours.
|
|
A value of -2147483648 indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 6 }
|
|
|
|
airFMModRHBlwr2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 2 run hours.
|
|
A value of -2147483648 indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 7 }
|
|
|
|
airFMModRHBlwrCtrl1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower Controller 1 run hours.
|
|
A value of -2147483648 indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 8 }
|
|
|
|
airFMModRHBlwrCtrl2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower Controller 2 run hours.
|
|
A value of -2147483648 indicates that this OID
|
|
does not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 9 }
|
|
|
|
airFMModRHComp1Reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the compressor 1 run hours.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 10 }
|
|
|
|
airFMModRHComp2Reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the compressor 2 run hours.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 11 }
|
|
|
|
airFMModRHHeaterReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the heater run hours.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 12 }
|
|
|
|
airFMModRHHumReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the humidifier run hours.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 13 }
|
|
|
|
airFMModRHBlwr1Reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the blower 1 run hours.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 14 }
|
|
|
|
airFMModRHBlwr2Reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the blower 2 run hours.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModRHEntry 15 }
|
|
|
|
-- airFM Module Service Intervals
|
|
|
|
airFMModServIntComp1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The interval at which to generate a maintenance alarm
|
|
for compressor 1. Values stored in increments of 100
|
|
hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntervals 1 }
|
|
|
|
airFMModServIntComp2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The interval at which to generate a maintenance alarm
|
|
for compressor 2. Values stored in increments of 100
|
|
hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntervals 2 }
|
|
|
|
airFMModServIntHeater OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The interval at which to generate a maintenance alarm
|
|
for the reheat components. Values stored in
|
|
increments of 100 hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntervals 3 }
|
|
|
|
airFMModServIntHum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The interval at which to generate a maintenance alarm
|
|
for the humidifier. Values stored in increments of
|
|
100 hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntervals 4 }
|
|
|
|
airFMModServIntBlwr1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The interval at which to generate a maintenance alarm
|
|
for blower 1. Values stored in increments of 100
|
|
hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntervals 5 }
|
|
|
|
airFMModServIntBlwr2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The interval at which to generate a maintenance alarm
|
|
for blower 2. Values stored in increments of 100
|
|
hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntervals 6 }
|
|
|
|
airFMModServIntBlwrCtrl1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The interval at which to generate a maintenance alarm
|
|
for blower controller 1. Values stored in increments
|
|
of 100 hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntervals 7 }
|
|
|
|
airFMModServIntBlwrCtrl2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The interval at which to generate a maintenance alarm
|
|
for blower controller 2. Values stored in increments
|
|
of 100 hours.
|
|
A value of -2147483648 indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntervals 8 }
|
|
|
|
-- airFM Module Service Intervals Reset Table
|
|
|
|
airFMModServIntResetTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the airFMModServIntTable. "
|
|
::= { airFMModServIntResets 1 }
|
|
|
|
airFMModServIntResetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMModServIntResetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each module in
|
|
the system. "
|
|
::= { airFMModServIntResets 2 }
|
|
|
|
airFMModServIntResetEntry OBJECT-TYPE
|
|
SYNTAX AirFMModServIntResetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module to get information from."
|
|
INDEX { airFMModServIntResetModuleIndex }
|
|
::= { airFMModServIntResetTable 1 }
|
|
|
|
AirFMModServIntResetEntry ::=
|
|
SEQUENCE {
|
|
airFMModServIntResetModuleIndex INTEGER,
|
|
airFMModServIntComp1Reset INTEGER,
|
|
airFMModServIntComp2Reset INTEGER,
|
|
airFMModServIntHeaterReset INTEGER,
|
|
airFMModServIntHumReset INTEGER,
|
|
airFMModServIntBlwr1Reset INTEGER,
|
|
airFMModServIntBlwr2Reset INTEGER,
|
|
airFMModServIntBlwrCtrl1Reset INTEGER,
|
|
airFMModServIntBlwrCtrl2Reset INTEGER
|
|
}
|
|
|
|
airFMModServIntResetModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the module."
|
|
::= { airFMModServIntResetEntry 1 }
|
|
|
|
airFMModServIntComp1Reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the compressor 1 service interval maintenance
|
|
alarm.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntResetEntry 2 }
|
|
|
|
airFMModServIntComp2Reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the compressor 2 service interval maintenance
|
|
alarm.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntResetEntry 3 }
|
|
|
|
airFMModServIntHeaterReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the heater service interval maintenance alarm.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntResetEntry 4 }
|
|
|
|
airFMModServIntHumReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the humidifier service interval maintenance
|
|
alarm.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntResetEntry 5 }
|
|
|
|
airFMModServIntBlwr1Reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the blower 1 service interval maintenance
|
|
alarm.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntResetEntry 6 }
|
|
|
|
airFMModServIntBlwr2Reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the blower 2 service interval maintenance
|
|
alarm.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntResetEntry 7 }
|
|
|
|
airFMModServIntBlwrCtrl1Reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the blower controller 1 service interval
|
|
maintenance alarm.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntResetEntry 8 }
|
|
|
|
airFMModServIntBlwrCtrl2Reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noOperation (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the blower controller 2 service interval
|
|
maintenance alarm.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value.
|
|
A value of notApplicable indicates that this OID does
|
|
not apply to this device due to its configuration."
|
|
::= { airFMModServIntResetEntry 9 }
|
|
|
|
-- airFM Alarms Table
|
|
|
|
airFMAlarmClearActiveGroupAlarms OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
clearAlarms (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clear active group alarms. If alarm conditions are
|
|
still present, new alarms will be generated for those
|
|
conditions.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value."
|
|
::= { airFMAlarms 1 }
|
|
|
|
airFMAlarmClearActiveSysModAlarms OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
clearAlarms (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clear active system and module alarms. If alarm
|
|
conditions are still present, new alarms will be
|
|
generated for those conditions.
|
|
Getting this OID will do nothing and return the
|
|
noOperation value."
|
|
::= { airFMAlarms 2 }
|
|
|
|
airFMAlarmConditionsTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active alarm conditions in the
|
|
airFMAlarmConditionTable."
|
|
::= { airFMAlarms 3 }
|
|
|
|
airFMAlarmConditionsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirFMAlarmConditionsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of active alarm conditions for the device."
|
|
::= { airFMAlarms 4 }
|
|
|
|
airFMAlarmConditionsEntry OBJECT-TYPE
|
|
SYNTAX AirFMAlarmConditionsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Alarm condition specification"
|
|
INDEX { airFMAlarmConditionsIndex }
|
|
::= { airFMAlarmConditionsTable 1 }
|
|
|
|
AirFMAlarmConditionsEntry ::= SEQUENCE {
|
|
airFMAlarmConditionsIndex INTEGER,
|
|
airFMAlarmSeverity INTEGER,
|
|
airFMAlarmType INTEGER,
|
|
airFMEventCode INTEGER,
|
|
airFMAlarmDate DisplayString,
|
|
airFMAlarmTime DisplayString,
|
|
airFMAlarmDescription DisplayString
|
|
}
|
|
|
|
airFMAlarmConditionsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alarm condition index."
|
|
::= { airFMAlarmConditionsEntry 1 }
|
|
|
|
airFMAlarmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
informational (1),
|
|
warningMinor (2),
|
|
criticalMajor (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Severity of the alarm."
|
|
::= { airFMAlarmConditionsEntry 2 }
|
|
|
|
airFMAlarmType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
group (1),
|
|
system (2),
|
|
mainMod (3),
|
|
expMod1 (4),
|
|
expMod2 (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Type of alarm."
|
|
::= { airFMAlarmConditionsEntry 3 }
|
|
|
|
airFMEventCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "APC event code for the alarm."
|
|
::= { airFMAlarmConditionsEntry 4 }
|
|
|
|
airFMAlarmDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Date the alarm was recorded."
|
|
::= { airFMAlarmConditionsEntry 5 }
|
|
|
|
airFMAlarmTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Time the alarm was recorded."
|
|
::= { airFMAlarmConditionsEntry 6 }
|
|
|
|
airFMAlarmDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Description of the alarm."
|
|
::= { airFMAlarmConditionsEntry 7 }
|
|
|
|
-- airPA Portable Air Conditioner Ident
|
|
|
|
airPAIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the device name."
|
|
::= { airPAIdent 1 }
|
|
|
|
airPAModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the device model number."
|
|
::= { airPAIdent 2 }
|
|
|
|
airPADateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying when the device was produced."
|
|
::= { airPAIdent 3 }
|
|
|
|
airPASerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the device serial number."
|
|
::= { airPAIdent 4 }
|
|
|
|
airPAFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the device firmware revision."
|
|
::= { airPAIdent 5 }
|
|
|
|
airPAHardwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the device hardware revision."
|
|
::= { airPAIdent 6 }
|
|
|
|
-- airPA Portable Air Conditioner Status
|
|
|
|
airPASystemPower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerON (1),
|
|
powerOFF (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the unit's system power setting.
|
|
|
|
ON(1) The system power is turned on.
|
|
OFF(2) The system power is turned off. "
|
|
::= { airPAStatus 1 }
|
|
|
|
airPAOperatingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modeOFF (1),
|
|
modeVENTING (2),
|
|
modeCOOLING (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current operating mode of the unit.
|
|
|
|
OFF(1) The system is off.
|
|
VENTING(2) The system's venting function is active.
|
|
COOLING(3) The system's cooling function is active. "
|
|
::= { airPAStatus 2 }
|
|
|
|
airPASetpointTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature setpoint in Fahrenheit to which the unit is controlling. "
|
|
::= { airPAStatus 3 }
|
|
|
|
airPASetpointTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature setpoint in Celsius to which the unity is controlling. "
|
|
::= { airPAStatus 4 }
|
|
|
|
airPABlowerSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
speedLOW (1),
|
|
speedHIGH (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit's blower speed setting.
|
|
|
|
LOW(1) The blower speed is low.
|
|
HIGH(2) The blower speed is high. "
|
|
::= { airPAStatus 5 }
|
|
|
|
airPACompressor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusON (1),
|
|
statusOFF (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit's compressor status.
|
|
|
|
ON(1) The compressor is turned on.
|
|
OFF(2) The compressor is turned off. "
|
|
::= { airPAStatus 6 }
|
|
|
|
airPACondenserFan OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusON (1),
|
|
statusOFF (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit's condenser fan status.
|
|
|
|
ON(1) The condenser fan is turned on.
|
|
OFF(2) The condenser fan is turned off. "
|
|
::= { airPAStatus 7 }
|
|
|
|
airPACondensatePump OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
statusON (1),
|
|
statusOFF (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit's condensate pump status.
|
|
|
|
ON(1) The condensate pump is turned on.
|
|
OFF(2) The condensate pump is turned off. "
|
|
::= { airPAStatus 8 }
|
|
|
|
airPASupplyTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The supply temperature in degrees Fahrenheit. "
|
|
::= { airPAStatus 9 }
|
|
|
|
airPASupplyTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The supply temperature in degrees Celsius. "
|
|
::= { airPAStatus 10 }
|
|
|
|
airPAReturnTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The return temperature in degrees Fahrenheit. "
|
|
::= { airPAStatus 11 }
|
|
|
|
airPAReturnTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The return temperature in degrees Celsius. "
|
|
::= { airPAStatus 12 }
|
|
|
|
airPARemoteTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The remote temperature in degrees Fahrenheit. "
|
|
::= { airPAStatus 13 }
|
|
|
|
airPARemoteTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The remote temperature in degrees Celsius. "
|
|
::= { airPAStatus 14 }
|
|
|
|
airPARemoteHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The remote humidity. "
|
|
::= { airPAStatus 15 }
|
|
|
|
-- air InRow Air Conditioners
|
|
-- airIR AIR CONDITIONER Alarm Status - shared across all IR products
|
|
|
|
airIRAlarmConditionsTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active alarm conditions in the airIRAlarmConditionTable."
|
|
::= { airIRAlarms 1 }
|
|
|
|
airIRAlarmConditionsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRAlarmConditionsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of active alarm conditions for the device."
|
|
::= { airIRAlarms 2 }
|
|
|
|
airIRAlarmConditionsEntry OBJECT-TYPE
|
|
SYNTAX AirIRAlarmConditionsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Alarm condition specification"
|
|
INDEX { airIRAlarmConditionsIndex }
|
|
::= { airIRAlarmConditionsTable 1 }
|
|
|
|
AirIRAlarmConditionsEntry ::= SEQUENCE {
|
|
airIRAlarmConditionsIndex INTEGER,
|
|
airIREventCode INTEGER,
|
|
airIRAlarmDescription DisplayString
|
|
}
|
|
|
|
airIRAlarmConditionsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Alarm condition index."
|
|
::= { airIRAlarmConditionsEntry 1 }
|
|
|
|
airIREventCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Code for the alarm."
|
|
::= { airIRAlarmConditionsEntry 2 }
|
|
|
|
airIRAlarmDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Description of the alarm."
|
|
::= { airIRAlarmConditionsEntry 3 }
|
|
|
|
-- airIRRC AIR CONDITIONER Group Status
|
|
|
|
airIRRCGroupStatusCoolOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group coolant output in tenths of kW."
|
|
::= { airIRRCGroupStatus 1 }
|
|
|
|
airIRRCGroupStatusCoolDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group coolant demand in tenths of kW."
|
|
::= { airIRRCGroupStatus 2 }
|
|
|
|
airIRRCGroupStatusAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group air flow in cubic feet per minute."
|
|
::= { airIRRCGroupStatus 3 }
|
|
|
|
airIRRCGroupStatusAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group air flow in liters per second."
|
|
::= { airIRRCGroupStatus 4 }
|
|
|
|
airIRRCGroupStatusMaxRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group maximum rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRCGroupStatus 5 }
|
|
|
|
airIRRCGroupStatusMaxRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group maximum rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRCGroupStatus 6 }
|
|
|
|
airIRRCGroupStatusMinRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group minimum rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRCGroupStatus 7 }
|
|
|
|
airIRRCGroupStatusMinRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group minimum rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRCGroupStatus 8 }
|
|
|
|
airIRRCGroupStatusActiveFlowControlStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
under (1),
|
|
okay (2),
|
|
over (3),
|
|
notApplicable (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of the active flow control
|
|
system."
|
|
::= { airIRRCGroupStatus 9 }
|
|
|
|
|
|
-- airIRRC AIR CONDITIONER Group Setpoints
|
|
|
|
airIRRCGroupSetpointsCoolUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRCGroupSetpoints 1 }
|
|
|
|
airIRRCGroupSetpointsCoolMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRCGroupSetpoints 2 }
|
|
|
|
airIRRCGroupSetpointsSupplyAirUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRCGroupSetpoints 3 }
|
|
|
|
airIRRCGroupSetpointsSupplyAirMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRCGroupSetpoints 4 }
|
|
|
|
airIRRCGroupSetpointsFanSpeedPreference OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low (1),
|
|
med-low (2),
|
|
med (3),
|
|
med-high (4),
|
|
high (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The preferred fan speed setting."
|
|
::= { airIRRCGroupSetpoints 5 }
|
|
|
|
airIRRCGroupSetpointsFanSpeedControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
manual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fan speed control setting.
|
|
Automatic(1) - controller manages fan speed.
|
|
Manual(2) - fan speed is fixed and set by the fan speed preference.
|
|
See airIRRCGroupSetpointsFanSpeedPreference."
|
|
::= { airIRRCGroupSetpoints 6 }
|
|
|
|
airIRRCGroupSetpointsActiveFlowControlBias OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive (1),
|
|
slightlyPositive (2),
|
|
zero (3),
|
|
slightlyNegative (4),
|
|
negative (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The active flow control bias setting."
|
|
::= { airIRRCGroupSetpoints 7 }
|
|
|
|
-- airIRRC AIR CONDITIONER Group Config
|
|
|
|
airIRRCGroupConfigNumberofCoolingUnits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of cooling units present in the group."
|
|
::= { airIRRCGroupConfig 1 }
|
|
|
|
airIRRCGroupConfigConfigurationType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
racs (1),
|
|
hacs (2),
|
|
in-row (3),
|
|
cacs (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group configuration type."
|
|
::= { airIRRCGroupConfig 2 }
|
|
|
|
airIRRCGroupConfigPctGlycol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The glycol mixture in percent."
|
|
::= { airIRRCGroupConfig 3 }
|
|
|
|
airIRRCGroupConfigCoolGainP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The gain component of the PID in hundredths."
|
|
::= { airIRRCGroupConfig 4 }
|
|
|
|
airIRRCGroupConfigCoolResetRateI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The integral component of the PID in hundredths."
|
|
::= { airIRRCGroupConfig 5 }
|
|
|
|
airIRRCGroupConfigCoolDerivativeD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The derivative component of the PID in hundredths."
|
|
::= { airIRRCGroupConfig 6 }
|
|
|
|
airIRRCGroupConfigMaxFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum desired fan speed setting in percent."
|
|
::= { airIRRCGroupConfig 7 }
|
|
|
|
airIRRCGroupConfigNumberOfActiveFlowControllers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active flow controllers
|
|
present in the group."
|
|
::= { airIRRCGroupConfig 8 }
|
|
|
|
airIRRCGroupConfigActiveFlowControllerLampTest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Turns off/on the active flow
|
|
controller lamp test."
|
|
::= { airIRRCGroupConfig 9 }
|
|
|
|
airIRRCGroupConfigAltitudeUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group altitude of the units above sea level in feet."
|
|
::= { airIRRCGroupConfig 10 }
|
|
|
|
airIRRCGroupConfigAltitudeMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group altitude of the units above sea level in meters."
|
|
::= { airIRRCGroupConfig 11 }
|
|
|
|
-- airIRRC AIR CONDITIONER UNIT Status
|
|
|
|
airIRRCUnitStatusOperateMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby (1),
|
|
on (2),
|
|
idle (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cooling unit operating mode."
|
|
::= { airIRRCUnitStatus 1 }
|
|
|
|
airIRRCUnitStatusCoolOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit cooling output in tenths of kW."
|
|
::= { airIRRCUnitStatus 2 }
|
|
|
|
airIRRCUnitStatusCoolDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit cooling demand in tenths of kW."
|
|
::= { airIRRCUnitStatus 3 }
|
|
|
|
airIRRCUnitStatusAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air flow in cubic feet per minute."
|
|
::= { airIRRCUnitStatus 4 }
|
|
|
|
airIRRCUnitStatusAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air flow in hundredths of
|
|
liters per second."
|
|
::= { airIRRCUnitStatus 5 }
|
|
|
|
airIRRCUnitStatusRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRCUnitStatus 6 }
|
|
|
|
airIRRCUnitStatusRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRCUnitStatus 7 }
|
|
|
|
airIRRCUnitStatusSupplyAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit supply air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRCUnitStatus 8 }
|
|
|
|
airIRRCUnitStatusSupplyAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit supply air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRCUnitStatus 9 }
|
|
|
|
airIRRCUnitStatusReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit return air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRCUnitStatus 10 }
|
|
|
|
airIRRCUnitStatusReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit return air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRCUnitStatus 11 }
|
|
|
|
airIRRCUnitStatusContainmtDPUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit containment differential pressure in
|
|
hundredths of inches of water."
|
|
::= { airIRRCUnitStatus 12 }
|
|
|
|
airIRRCUnitStatusContainmtDPMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit containment differential pressure in Pa."
|
|
::= { airIRRCUnitStatus 13 }
|
|
|
|
airIRRCUnitStatusFilterDPUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air filter differential pressure in
|
|
hundredths of inches of water."
|
|
::= { airIRRCUnitStatus 14 }
|
|
|
|
airIRRCUnitStatusFilterDPMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air filter differential pressure in Pa."
|
|
::= { airIRRCUnitStatus 15 }
|
|
|
|
airIRRCUnitStatusFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit average fan speed in tenths of percent."
|
|
::= { airIRRCUnitStatus 16 }
|
|
|
|
airIRRCUnitStatusInputState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the input contact."
|
|
::= { airIRRCUnitStatus 17 }
|
|
|
|
airIRRCUnitStatusOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the output relay."
|
|
::= { airIRRCUnitStatus 18 }
|
|
|
|
airIRRCUnitStatusActivePowerSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sourceA (1),
|
|
sourceB (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power source that is powering the unit."
|
|
::= { airIRRCUnitStatus 19 }
|
|
|
|
airIRRCUnitStatusFluidValvePosition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fluid valve position in percent open."
|
|
::= { airIRRCUnitStatus 20 }
|
|
|
|
airIRRCUnitStatusFluidFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fluid flow in tenths of gallons per minute."
|
|
::= { airIRRCUnitStatus 21 }
|
|
|
|
airIRRCUnitStatusFluidFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fluid flow in hundredths of liters per second."
|
|
::= { airIRRCUnitStatus 22 }
|
|
|
|
airIRRCUnitStatusEnteringFluidTemperatureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the entering fluid in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRCUnitStatus 23 }
|
|
|
|
airIRRCUnitStatusEnteringFluidTemperatureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the entering fluid in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRCUnitStatus 24 }
|
|
|
|
airIRRCUnitStatusLeavingFluidTemperatureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the Leaving fluid in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRCUnitStatus 25 }
|
|
|
|
airIRRCUnitStatusLeavingFluidTemperatureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the Leaving fluid in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRCUnitStatus 26 }
|
|
|
|
|
|
-- airIRRC AIR CONDITIONER UNIT Ident
|
|
|
|
airIRRCUnitIdentID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit identification number."
|
|
::= { airIRRCUnitIdent 1 }
|
|
|
|
airIRRCUnitIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit name."
|
|
::= { airIRRCUnitIdent 2 }
|
|
|
|
airIRRCUnitIdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit location."
|
|
::= { airIRRCUnitIdent 3 }
|
|
|
|
airIRRCUnitIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit model number."
|
|
::= { airIRRCUnitIdent 4 }
|
|
|
|
airIRRCUnitIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit serial number."
|
|
::= { airIRRCUnitIdent 5 }
|
|
|
|
airIRRCUnitIdentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit firmware version."
|
|
::= { airIRRCUnitIdent 6 }
|
|
|
|
airIRRCUnitIdentHardwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit controller hardware revision."
|
|
::= { airIRRCUnitIdent 7 }
|
|
|
|
airIRRCUnitIdentManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit manufacture date."
|
|
::= { airIRRCUnitIdent 8 }
|
|
|
|
|
|
-- airIRRC AIR CONDITIONER UNIT Runhours
|
|
|
|
airIRRCUnitRunHoursAirFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit air filter run hours."
|
|
::= { airIRRCUnitRunHours 1 }
|
|
|
|
airIRRCUnitRunHoursFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 1 run hours."
|
|
::= { airIRRCUnitRunHours 2 }
|
|
|
|
airIRRCUnitRunHoursFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 2 run hours."
|
|
::= { airIRRCUnitRunHours 3 }
|
|
|
|
airIRRCUnitRunHoursFan3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 3 run hours."
|
|
::= { airIRRCUnitRunHours 4 }
|
|
|
|
airIRRCUnitRunHoursFan4 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 4 run hours."
|
|
::= { airIRRCUnitRunHours 5 }
|
|
|
|
airIRRCUnitRunHoursFan5 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 5 run hours."
|
|
::= { airIRRCUnitRunHours 6 }
|
|
|
|
airIRRCUnitRunHoursFan6 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 6 run hours."
|
|
::= { airIRRCUnitRunHours 7 }
|
|
|
|
airIRRCUnitRunHoursFan7 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 7 run hours."
|
|
::= { airIRRCUnitRunHours 8}
|
|
|
|
airIRRCUnitRunHoursFan8 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 8 run hours."
|
|
::= { airIRRCUnitRunHours 9 }
|
|
|
|
airIRRCUnitRunHoursFanPowerSupplyLeft OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan left power supply run hours."
|
|
::= { airIRRCUnitRunHours 10 }
|
|
|
|
airIRRCUnitRunHoursFanPowerSupplyRight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan right power supply run hours."
|
|
::= { airIRRCUnitRunHours 11 }
|
|
|
|
airIRRCUnitRunHoursCondensatePump OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condensate pump run hours."
|
|
::= { airIRRCUnitRunHours 12 }
|
|
|
|
airIRRCUnitRunHoursFanPowerSupplyFeedALeft OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan, DC power feed A, left power supply run hours.
|
|
This is only valid for a DC input unit."
|
|
::= { airIRRCUnitRunHours 13 }
|
|
|
|
airIRRCUnitRunHoursFanPowerSupplyFeedARight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan, DC power feed A, right power supply run hours.
|
|
This is only valid for a DC input unit."
|
|
::= { airIRRCUnitRunHours 14 }
|
|
|
|
airIRRCUnitRunHoursFanPowerSupplyFeedBLeft OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan, DC power feed B, left power supply run hours.
|
|
This is only valid for a DC input unit."
|
|
::= { airIRRCUnitRunHours 15 }
|
|
|
|
airIRRCUnitRunHoursFanPowerSupplyFeedBRight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan, DC power feed B, right power supply run hours.
|
|
This is only valid for a DC input unit."
|
|
::= { airIRRCUnitRunHours 16 }
|
|
|
|
-- airIRRC AIR CONDITIONER UNIT Service Intervals
|
|
|
|
airIRRCUnitServiceIntervalsAirFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Air filter service interval in weeks."
|
|
::= { airIRRCUnitServiceIntervals 1 }
|
|
|
|
airIRRCUnitServiceIntervalsAirFilterAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The air filter service interval alarm enable/disable."
|
|
::= { airIRRCUnitServiceIntervals 2 }
|
|
|
|
|
|
-- airIRRC AIR CONDITIONER UNIT Thresholds
|
|
|
|
airIRRCUnitThresholdsRackInletHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit rack inlet air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRCUnitThresholds 1 }
|
|
|
|
airIRRCUnitThresholdsRackInletHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit rack inlet air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRCUnitThresholds 2 }
|
|
|
|
airIRRCUnitThresholdsSupplyAirHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRCUnitThresholds 3 }
|
|
|
|
airIRRCUnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRCUnitThresholds 4 }
|
|
|
|
airIRRCUnitThresholdsReturnAirHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit return air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRCUnitThresholds 5 }
|
|
|
|
airIRRCUnitThresholdsReturnAirHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit return air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRCUnitThresholds 6 }
|
|
|
|
airIRRCUnitThresholdsEnteringFluidHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit entering fluid high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRCUnitThresholds 7 }
|
|
|
|
airIRRCUnitThresholdsEnteringFluidHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit incoming fluid high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRCUnitThresholds 8 }
|
|
|
|
|
|
-- airIRRC AIR CONDITIONER UNIT Config
|
|
|
|
airIRRCUnitConfigCoolCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
maximum (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cooling capacity options setting."
|
|
::= { airIRRCUnitConfig 1 }
|
|
|
|
airIRRCUnitConfigStartupDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The startup delay in seconds."
|
|
::= { airIRRCUnitConfig 2 }
|
|
|
|
airIRRCUnitConfigIdleOnLeakDetect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The idle on leak options setting."
|
|
::= { airIRRCUnitConfig 3 }
|
|
|
|
airIRRCUnitConfigPowerSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sourceA (1),
|
|
sourceB (2),
|
|
sourceAandB (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The configured power source of the unit."
|
|
::= { airIRRCUnitConfig 4 }
|
|
|
|
airIRRCUnitConfigInputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of the input contact."
|
|
::= { airIRRCUnitConfig 5 }
|
|
|
|
airIRRCUnitConfigOutputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of the output relay."
|
|
::= { airIRRCUnitConfig 6 }
|
|
|
|
airIRRCUnitConfigOutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
anyAlarm (1),
|
|
criticalAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The source of output relay change."
|
|
::= { airIRRCUnitConfig 7 }
|
|
|
|
airIRRCUnitConfigIdleOnCoolFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The idle on cool fail options setting.
|
|
If yes, the system will go into idle mode
|
|
when a cooling failure is detected.
|
|
If no, the system will not go into idle mode
|
|
when a cooling failure is detected. "
|
|
::= { airIRRCUnitConfig 8 }
|
|
|
|
|
|
-- airIRRP100 AIR CONDITIONER Group Status
|
|
|
|
airIRRP100GroupStatusAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group air flow in cubic feet per minute."
|
|
::= { airIRRP100GroupStatus 1 }
|
|
|
|
airIRRP100GroupStatusAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group air flow in liters per second."
|
|
::= { airIRRP100GroupStatus 2 }
|
|
|
|
airIRRP100GroupStatusMaxRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group maximum rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100GroupStatus 3 }
|
|
|
|
airIRRP100GroupStatusMaxRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group maximum rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100GroupStatus 4 }
|
|
|
|
airIRRP100GroupStatusMinRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group minimum rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100GroupStatus 5 }
|
|
|
|
airIRRP100GroupStatusMinRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group minimum rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100GroupStatus 6 }
|
|
|
|
airIRRP100GroupStatusCoolDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group coolant demand in tenths of kiloWatts."
|
|
::= { airIRRP100GroupStatus 7 }
|
|
|
|
airIRRP100GroupStatusCoolOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group coolant output in tenths of kiloWatts."
|
|
::= { airIRRP100GroupStatus 8 }
|
|
|
|
airIRRP100GroupStatusHumidifyDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of humidification the group is demanding
|
|
from the humidifiers in percent."
|
|
::= { airIRRP100GroupStatus 9 }
|
|
|
|
airIRRP100GroupStatusHumidifyOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual amount of humidification the group is
|
|
supplying in percent."
|
|
::= { airIRRP100GroupStatus 10 }
|
|
|
|
airIRRP100GroupStatusDehumidifyDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of dehumidification the group is demanding
|
|
from the electric heaters in percent."
|
|
::= { airIRRP100GroupStatus 11 }
|
|
|
|
airIRRP100GroupStatusDehumidifyOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual amount of dehumidification the group is
|
|
supplying in percent."
|
|
::= { airIRRP100GroupStatus 12 }
|
|
|
|
airIRRP100GroupStatusReheatDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of heating the group is demanding
|
|
from the electric heaters in percent."
|
|
::= { airIRRP100GroupStatus 13 }
|
|
|
|
airIRRP100GroupStatusReheatOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual amount of heating the group is
|
|
supplying in percent."
|
|
::= { airIRRP100GroupStatus 14 }
|
|
|
|
airIRRP100GroupStatusActiveFlowControlStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
under (1),
|
|
okay (2),
|
|
over (3),
|
|
notApplicable (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of the active flow control
|
|
system."
|
|
::= { airIRRP100GroupStatus 15 }
|
|
|
|
airIRRP100GroupStatusDewPointTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group average dew point temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100GroupStatus 16 }
|
|
|
|
airIRRP100GroupStatusDewPointTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group average dew point temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100GroupStatus 17 }
|
|
|
|
|
|
-- airIRRP100 AIR CONDITIONER Group Setpoints
|
|
|
|
airIRRP100GroupSetpointsCoolUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100GroupSetpoints 1 }
|
|
|
|
airIRRP100GroupSetpointsCoolMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100GroupSetpoints 2 }
|
|
|
|
airIRRP100GroupSetpointsSupplyAirUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100GroupSetpoints 3 }
|
|
|
|
airIRRP100GroupSetpointsSupplyAirMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100GroupSetpoints 4 }
|
|
|
|
airIRRP100GroupSetpointsHumidify OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group humidify setpoint in tenths of
|
|
percent relative humidity."
|
|
::= { airIRRP100GroupSetpoints 5 }
|
|
|
|
airIRRP100GroupSetpointsDehumidify OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group dehumidify setpoint in tenths of
|
|
percent relative humidity."
|
|
::= { airIRRP100GroupSetpoints 6 }
|
|
|
|
airIRRP100GroupSetpointsDehumidifyDeadband OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group dehumidify deadband in percent relative humidity."
|
|
::= { airIRRP100GroupSetpoints 7 }
|
|
|
|
airIRRP100GroupSetpointsReheatUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100GroupSetpoints 8 }
|
|
|
|
airIRRP100GroupSetpointsReheatMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100GroupSetpoints 9 }
|
|
|
|
airIRRP100GroupSetpointsFanSpeedPreference OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low (1),
|
|
med-low (2),
|
|
med (3),
|
|
med-high (4),
|
|
high (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The preferred fan speed setting."
|
|
::= { airIRRP100GroupSetpoints 10 }
|
|
|
|
airIRRP100GroupSetpointsFanSpeedControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
manual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fan speed control setting."
|
|
::= { airIRRP100GroupSetpoints 11 }
|
|
|
|
airIRRP100GroupSetpointsActiveFlowControlBias OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive (1),
|
|
slightlyPositive (2),
|
|
zero (3),
|
|
slightlyNegative (4),
|
|
negative (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The active flow control bias setting."
|
|
::= { airIRRP100GroupSetpoints 12 }
|
|
|
|
-- airIRRP100 AIR CONDITIONER Group Config
|
|
|
|
airIRRP100GroupConfigNumberofCoolingUnits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of cooling units present in the group."
|
|
::= { airIRRP100GroupConfig 1 }
|
|
|
|
airIRRP100GroupConfigConfigurationType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
racs (1),
|
|
hacs (2),
|
|
in-row (3),
|
|
cacs (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group configuration type."
|
|
::= { airIRRP100GroupConfig 2 }
|
|
|
|
airIRRP100GroupConfigCoolGainP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The gain component of the cool PID in hundredths."
|
|
::= { airIRRP100GroupConfig 3 }
|
|
|
|
airIRRP100GroupConfigCoolResetRateI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The integral component of the cool PID in hundredths."
|
|
::= { airIRRP100GroupConfig 4 }
|
|
|
|
airIRRP100GroupConfigCoolDerivativeD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The derivative component of the cool PID in hundredths."
|
|
::= { airIRRP100GroupConfig 5 }
|
|
|
|
airIRRP100GroupConfigHumidifySensitivityBand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percent relative humidity below the setpoint that
|
|
will cause the humidifier to run at 100% capacity."
|
|
::= { airIRRP100GroupConfig 6 }
|
|
|
|
airIRRP100GroupConfigReheatGainP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The gain component of the reheat PID in hundredths."
|
|
::= { airIRRP100GroupConfig 7 }
|
|
|
|
airIRRP100GroupConfigReheatResetRateI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The integral component of the reheat PID in hundredths."
|
|
::= { airIRRP100GroupConfig 8 }
|
|
|
|
airIRRP100GroupConfigReheatDerivativeD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The derivative component of the reheat PID in hundredths."
|
|
::= { airIRRP100GroupConfig 9 }
|
|
|
|
airIRRP100GroupConfigNumberofBackupUnits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of backup units."
|
|
::= { airIRRP100GroupConfig 10 }
|
|
|
|
airIRRP100GroupConfigRuntimeBalancingEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable runtime balancing feature."
|
|
::= { airIRRP100GroupConfig 11 }
|
|
|
|
airIRRP100GroupConfigLoadAssistEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable load assist feature."
|
|
::= { airIRRP100GroupConfig 12 }
|
|
|
|
airIRRP100GroupConfigFullRPBackups OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of full featured RPs that can be used as backup units."
|
|
::= { airIRRP100GroupConfig 13 }
|
|
|
|
airIRRP100GroupConfigMaxFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum desired fan speed setting in percent."
|
|
::= { airIRRP100GroupConfig 14 }
|
|
|
|
airIRRP100GroupConfigNumberOfActiveFlowControllers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active flow controllers
|
|
present in the group."
|
|
::= { airIRRP100GroupConfig 15 }
|
|
|
|
airIRRP100GroupConfigActiveFlowControllerLampTest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Turns off/on the active flow
|
|
controller lamp test."
|
|
::= { airIRRP100GroupConfig 16 }
|
|
|
|
airIRRP100GroupConfigAltitudeUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group altitude of the units above sea level in feet."
|
|
::= { airIRRP100GroupConfig 17 }
|
|
|
|
airIRRP100GroupConfigAltitudeMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group altitude of the units above sea level in meters."
|
|
::= { airIRRP100GroupConfig 18 }
|
|
|
|
-- airIRRP100 AIR CONDITIONER UNIT Status
|
|
|
|
airIRRP100UnitStatusOperateMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby (1),
|
|
on (2),
|
|
idle (3),
|
|
prestart (4),
|
|
service (5),
|
|
backup (6),
|
|
assist (7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cooling unit operating mode."
|
|
::= { airIRRP100UnitStatus 1 }
|
|
|
|
airIRRP100UnitStatusRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100UnitStatus 2 }
|
|
|
|
airIRRP100UnitStatusRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100UnitStatus 3 }
|
|
|
|
airIRRP100UnitStatusSupplyAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit supply air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100UnitStatus 4 }
|
|
|
|
airIRRP100UnitStatusSupplyAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit supply air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100UnitStatus 5 }
|
|
|
|
airIRRP100UnitStatusReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit return air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100UnitStatus 6 }
|
|
|
|
airIRRP100UnitStatusReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit return air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100UnitStatus 7 }
|
|
|
|
airIRRP100UnitStatusSupplyHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative humidity of the supply air in
|
|
tenths of percent."
|
|
::= { airIRRP100UnitStatus 8 }
|
|
|
|
airIRRP100UnitStatusReturnHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative humidity of the return air in
|
|
tenths of percent."
|
|
::= { airIRRP100UnitStatus 9 }
|
|
|
|
airIRRP100UnitStatusAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air flow in cubic feet per minute."
|
|
::= { airIRRP100UnitStatus 10 }
|
|
|
|
airIRRP100UnitStatusAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air flow in hundredths of
|
|
liters per second."
|
|
::= { airIRRP100UnitStatus 11 }
|
|
|
|
airIRRP100UnitStatusFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit average fan speed in tenths of percent."
|
|
::= { airIRRP100UnitStatus 12 }
|
|
|
|
airIRRP100UnitStatusCoolDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit cooling demand in tenths of kiloWatts."
|
|
::= { airIRRP100UnitStatus 13 }
|
|
|
|
airIRRP100UnitStatusCoolOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit cooling output in tenths of kiloWatts."
|
|
::= { airIRRP100UnitStatus 14 }
|
|
|
|
airIRRP100UnitStatusHumidifyDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of humidification the unit is demanding
|
|
from the humidifier in percent."
|
|
::= { airIRRP100UnitStatus 15 }
|
|
|
|
airIRRP100UnitStatusHumidifyOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual humidification output of the unit
|
|
in percent."
|
|
::= { airIRRP100UnitStatus 16 }
|
|
|
|
airIRRP100UnitStatusDehumidifyDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of dehumidification the unit is
|
|
demanding in percent."
|
|
::= { airIRRP100UnitStatus 17 }
|
|
|
|
airIRRP100UnitStatusDehumidifyOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual dehumidification output of the unit
|
|
in percent."
|
|
::= { airIRRP100UnitStatus 18 }
|
|
|
|
airIRRP100UnitStatusReheatDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of heating the unit is demanding
|
|
from the electric heater in percent."
|
|
::= { airIRRP100UnitStatus 19 }
|
|
|
|
airIRRP100UnitStatusReheatOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual heating output of the unit
|
|
in percent."
|
|
::= { airIRRP100UnitStatus 20 }
|
|
|
|
airIRRP100UnitStatusInputState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the input contact."
|
|
::= { airIRRP100UnitStatus 21 }
|
|
|
|
airIRRP100UnitStatusOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the output relay."
|
|
::= { airIRRP100UnitStatus 22 }
|
|
|
|
airIRRP100UnitStatusRackInletTemperature1US OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100UnitStatus 23 }
|
|
|
|
airIRRP100UnitStatusRackInletTemperature1Metric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100UnitStatus 24 }
|
|
|
|
airIRRP100UnitStatusRackInletTemperature2US OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100UnitStatus 25 }
|
|
|
|
airIRRP100UnitStatusRackInletTemperature2Metric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100UnitStatus 26 }
|
|
|
|
airIRRP100UnitStatusRackInletTemperature3US OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP100UnitStatus 27 }
|
|
|
|
airIRRP100UnitStatusRackInletTemperature3Metric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP100UnitStatus 28 }
|
|
|
|
airIRRP100UnitStatusFilterDPUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air filter differential pressure in
|
|
hundredths of inches of water."
|
|
::= { airIRRP100UnitStatus 29 }
|
|
|
|
airIRRP100UnitStatusFilterDPMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air filter differential pressure in Pa."
|
|
::= { airIRRP100UnitStatus 30 }
|
|
|
|
airIRRP100UnitStatusContainmtDPUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit containment differential pressure in
|
|
hundredths of inches of water."
|
|
::= { airIRRP100UnitStatus 31 }
|
|
|
|
airIRRP100UnitStatusContainmtDPMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit containment differential pressure in Pa."
|
|
::= { airIRRP100UnitStatus 32 }
|
|
|
|
airIRRP100UnitStatusHumidifierCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidifier current of the unit
|
|
in tenths of amperes."
|
|
::= { airIRRP100UnitStatus 33 }
|
|
|
|
airIRRP100UnitStatusHumidifierWaterConductivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The water conductivity in the humidifier of the unit
|
|
in microSiemens/cm."
|
|
::= { airIRRP100UnitStatus 34 }
|
|
|
|
airIRRP100UnitStatusCompressorDriveSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The compressor drive speed in hundredths of Hertz."
|
|
::= { airIRRP100UnitStatus 35 }
|
|
|
|
airIRRP100UnitStatusCompressorDrivePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The compressor drive power consumption in
|
|
tenths of kiloWatts."
|
|
::= { airIRRP100UnitStatus 36 }
|
|
|
|
airIRRP100UnitStatusCompressorDriveVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The compressor drive voltage consumption in
|
|
tenths of volts."
|
|
::= { airIRRP100UnitStatus 37 }
|
|
|
|
airIRRP100UnitStatusCompressorDriveCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The compressor drive voltage consumption in
|
|
tenths of amperes."
|
|
::= { airIRRP100UnitStatus 38 }
|
|
|
|
airIRRP100UnitStatusCompressorDriveDCLinkVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The compressor drive DC link voltage in
|
|
tenths of volts."
|
|
::= { airIRRP100UnitStatus 39 }
|
|
|
|
airIRRP100UnitStatusCompressorDriveHeatSinkTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the compressor drive heatsink
|
|
in tenths of degrees Fahrenheit."
|
|
::= { airIRRP100UnitStatus 40 }
|
|
|
|
airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the compressor drive heatsink
|
|
in tenths of degrees Celsius."
|
|
::= { airIRRP100UnitStatus 41 }
|
|
|
|
airIRRP100UnitStatusCompressorDriveControlCardTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the compressor drive control card
|
|
in tenths of degrees Fahrenheit."
|
|
::= { airIRRP100UnitStatus 42 }
|
|
|
|
airIRRP100UnitStatusCompressorDriveControlCardTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the compressor drive control card
|
|
in tenths of degrees Celsius."
|
|
::= { airIRRP100UnitStatus 43 }
|
|
|
|
airIRRP100UnitStatusCompressorDriveWarningStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The four byte warning status of the compressor drive
|
|
in hexadecimal."
|
|
::= { airIRRP100UnitStatus 44 }
|
|
|
|
airIRRP100UnitStatusCompressorDriveAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The four byte alarm status of the compressor drive
|
|
in hexadecimal."
|
|
::= { airIRRP100UnitStatus 45 }
|
|
|
|
airIRRP100UnitStatusSuctionPressureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit suction pressure in pounds per square inch (PSI)."
|
|
::= { airIRRP100UnitStatus 46 }
|
|
|
|
airIRRP100UnitStatusSuctionPressureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit suction pressure in kiloPascals (kPa)."
|
|
::= { airIRRP100UnitStatus 47 }
|
|
|
|
airIRRP100UnitStatusDischargePressureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit discharge pressure in pounds per square inch (PSI)."
|
|
::= { airIRRP100UnitStatus 48 }
|
|
|
|
airIRRP100UnitStatusDischargePressureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit discharge pressure in kiloPascals (kPa)."
|
|
::= { airIRRP100UnitStatus 49 }
|
|
|
|
airIRRP100UnitStatusLeakSensor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no-leak (1),
|
|
leak (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state (no-leak/leak) of the leak sensor."
|
|
::= { airIRRP100UnitStatus 50 }
|
|
|
|
-- airIRRP100 AIR CONDITIONER UNIT Ident
|
|
|
|
airIRRP100UnitIdentID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit identification number."
|
|
::= { airIRRP100UnitIdent 1 }
|
|
|
|
airIRRP100UnitIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit name."
|
|
::= { airIRRP100UnitIdent 2 }
|
|
|
|
airIRRP100UnitIdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit location."
|
|
::= { airIRRP100UnitIdent 3 }
|
|
|
|
airIRRP100UnitIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit model number."
|
|
::= { airIRRP100UnitIdent 4 }
|
|
|
|
airIRRP100UnitIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit serial number."
|
|
::= { airIRRP100UnitIdent 5 }
|
|
|
|
airIRRP100UnitIdentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit firmware version."
|
|
::= { airIRRP100UnitIdent 6 }
|
|
|
|
airIRRP100UnitIdentHardwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit controller hardware revision."
|
|
::= { airIRRP100UnitIdent 7 }
|
|
|
|
airIRRP100UnitIdentManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit manufacture date."
|
|
::= { airIRRP100UnitIdent 8 }
|
|
|
|
|
|
-- airIRRP100 AIR CONDITIONER UNIT Runhours
|
|
|
|
airIRRP100UnitRunHoursAirFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit air filter run hours."
|
|
::= { airIRRP100UnitRunHours 1 }
|
|
|
|
airIRRP100UnitRunHoursCondensatePump OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condensate pump run hours."
|
|
::= { airIRRP100UnitRunHours 2 }
|
|
|
|
airIRRP100UnitRunHoursHumidifier OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan right power supply run hours."
|
|
::= { airIRRP100UnitRunHours 3 }
|
|
|
|
airIRRP100UnitRunHoursFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 1 run hours."
|
|
::= { airIRRP100UnitRunHours 4 }
|
|
|
|
airIRRP100UnitRunHoursHeater1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit heater 1 run hours."
|
|
::= { airIRRP100UnitRunHours 5 }
|
|
|
|
airIRRP100UnitRunHoursFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 2 run hours."
|
|
::= { airIRRP100UnitRunHours 6 }
|
|
|
|
airIRRP100UnitRunHoursHeater2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit Heater 2 run hours."
|
|
::= { airIRRP100UnitRunHours 7 }
|
|
|
|
airIRRP100UnitRunHoursCompressor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit compressor run hours."
|
|
::= { airIRRP100UnitRunHours 8 }
|
|
|
|
airIRRP100UnitRunHoursSystem OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total system run hours."
|
|
::= { airIRRP100UnitRunHours 9 }
|
|
|
|
|
|
-- airIRRP100 AIR CONDITIONER UNIT Service Intervals
|
|
|
|
airIRRP100UnitServiceIntervalAirFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Air filter service interval in weeks."
|
|
::= { airIRRP100UnitServiceIntervals 1 }
|
|
|
|
airIRRP100UnitServiceIntervalAirFilterAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The air filter service interval alarm enable/disable."
|
|
::= { airIRRP100UnitServiceIntervals 2 }
|
|
|
|
airIRRP100UnitServiceIntervalHumidifier OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier service interval in weeks."
|
|
::= { airIRRP100UnitServiceIntervals 3 }
|
|
|
|
airIRRP100UnitServiceIntervalHumidifierAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidifier service interval alarm enable/disable."
|
|
::= { airIRRP100UnitServiceIntervals 4 }
|
|
|
|
airIRRP100UnitServiceIntervalHeater OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Heater service interval in weeks."
|
|
::= { airIRRP100UnitServiceIntervals 5 }
|
|
|
|
airIRRP100UnitServiceIntervalHeaterAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The heater service interval alarm enable/disable."
|
|
::= { airIRRP100UnitServiceIntervals 6 }
|
|
|
|
airIRRP100UnitServiceIntervalCompressor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor service interval in weeks."
|
|
::= { airIRRP100UnitServiceIntervals 7 }
|
|
|
|
airIRRP100UnitServiceIntervalCompressorAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The compressor service interval alarm enable/disable."
|
|
::= { airIRRP100UnitServiceIntervals 8 }
|
|
|
|
airIRRP100UnitServiceIntervalCondensatePump OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Condensate pump service interval in weeks."
|
|
::= { airIRRP100UnitServiceIntervals 9 }
|
|
|
|
airIRRP100UnitServiceIntervalCondensatePumpAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The condensate pump service interval alarm enable/disable."
|
|
::= { airIRRP100UnitServiceIntervals 10 }
|
|
|
|
airIRRP100UnitServiceIntervalFans OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fans service interval in weeks."
|
|
::= { airIRRP100UnitServiceIntervals 11 }
|
|
|
|
airIRRP100UnitServiceIntervalFansAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fans service interval alarm enable/disable."
|
|
::= { airIRRP100UnitServiceIntervals 12 }
|
|
|
|
|
|
|
|
-- airIRRP100 AIR CONDITIONER UNIT Thresholds
|
|
|
|
airIRRP100UnitThresholdsRackInletHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit rack inlet air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRP100UnitThresholds 1 }
|
|
|
|
airIRRP100UnitThresholdsRackInletHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit rack inlet air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRP100UnitThresholds 2 }
|
|
|
|
airIRRP100UnitThresholdsSupplyAirHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRP100UnitThresholds 3 }
|
|
|
|
airIRRP100UnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRP100UnitThresholds 4 }
|
|
|
|
airIRRP100UnitThresholdsReturnAirHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit return air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRP100UnitThresholds 5 }
|
|
|
|
airIRRP100UnitThresholdsReturnAirHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit return air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRP100UnitThresholds 6 }
|
|
|
|
airIRRP100UnitThresholdsSupplyHumidityHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply humidity high threshold in
|
|
tenths of percent relative humidity."
|
|
::= { airIRRP100UnitThresholds 7 }
|
|
|
|
airIRRP100UnitThresholdsSupplyHumidityLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply humidity low threshold in
|
|
tenths of percent relative humidity."
|
|
::= { airIRRP100UnitThresholds 8 }
|
|
|
|
|
|
-- airIRRP100 AIR CONDITIONER UNIT Config
|
|
|
|
airIRRP100UnitConfigStartupDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The startup delay in seconds."
|
|
::= { airIRRP100UnitConfig 1 }
|
|
|
|
airIRRP100UnitConfigCoolCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
maximum (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cooling capacity options setting."
|
|
::= { airIRRP100UnitConfig 2 }
|
|
|
|
airIRRP100UnitConfigIdleOnLeakDetect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The idle on leak options setting."
|
|
::= { airIRRP100UnitConfig 3 }
|
|
|
|
airIRRP100UnitConfigInputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of the input contact."
|
|
::= { airIRRP100UnitConfig 4 }
|
|
|
|
airIRRP100UnitConfigOutputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of the output relay."
|
|
::= { airIRRP100UnitConfig 5 }
|
|
|
|
airIRRP100UnitConfigOutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
anyAlarm (1),
|
|
criticalAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The source of output relay change."
|
|
::= { airIRRP100UnitConfig 6 }
|
|
|
|
airIRRP100UnitConfigHumidifyEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/disable humidification."
|
|
::= { airIRRP100UnitConfig 7 }
|
|
|
|
airIRRP100UnitConfigHumidifierControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto (1),
|
|
drainOff (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidifier drain control."
|
|
::= { airIRRP100UnitConfig 8 }
|
|
|
|
airIRRP100UnitConfigDehumidifyEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/disable dehumidification."
|
|
::= { airIRRP100UnitConfig 9 }
|
|
|
|
airIRRP100UnitConfigReheatEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/disable reheat."
|
|
::= { airIRRP100UnitConfig 10 }
|
|
|
|
airIRRP100UnitConfigHeatAssistEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/disable heat assist."
|
|
::= { airIRRP100UnitConfig 11 }
|
|
|
|
airIRRP100UnitConfigPowerSourceConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
single (1),
|
|
dual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the input power source: (1) single feed or (2) dual feed."
|
|
::= { airIRRP100UnitConfig 12 }
|
|
|
|
airIRRP100UnitConfigUnitRoleOverride OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
forcedOn (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When this OID value is (1) automatic, the system determines
|
|
which units are used as primary units and which units are used as backups.
|
|
When this OID value is (2) forcedOn, the connected unit is set as a primary
|
|
unit."
|
|
::= { airIRRP100UnitConfig 13 }
|
|
|
|
airIRRP100UnitConfigSecondaryPowerFeedCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
full (1),
|
|
reduced (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available on chilled water units. When the power source config setting
|
|
is set to dual, setting this value to reduced (2) will inhibit the heater
|
|
and humdifier when the unit is being powered from the secondary
|
|
input."
|
|
::= { airIRRP100UnitConfig 14 }
|
|
|
|
airIRRP100UnitConfigIdleOnCoolFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When this OID value is (1) enable, the unit idles if it detects that it is blowing warm
|
|
air into the cold aisle. The unit will attempt to restart at 5 minute intervals."
|
|
::= { airIRRP100UnitConfig 15 }
|
|
|
|
-- airIRRP500 AIR CONDITIONER Group Status
|
|
|
|
airIRRP500GroupStatusAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group air flow in cubic feet per minute."
|
|
::= { airIRRP500GroupStatus 1 }
|
|
|
|
airIRRP500GroupStatusAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group air flow in liters per second."
|
|
::= { airIRRP500GroupStatus 2 }
|
|
|
|
airIRRP500GroupStatusMaxRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group maximum rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500GroupStatus 3 }
|
|
|
|
airIRRP500GroupStatusMaxRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group maximum rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500GroupStatus 4 }
|
|
|
|
airIRRP500GroupStatusMinRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group minimum rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500GroupStatus 5 }
|
|
|
|
airIRRP500GroupStatusMinRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group minimum rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500GroupStatus 6 }
|
|
|
|
airIRRP500GroupStatusCoolDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group coolant demand in tenths of kiloWatts."
|
|
::= { airIRRP500GroupStatus 7 }
|
|
|
|
airIRRP500GroupStatusCoolOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group coolant output in tenths of kiloWatts."
|
|
::= { airIRRP500GroupStatus 8 }
|
|
|
|
airIRRP500GroupStatusHumidifyDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of humidification the group is demanding
|
|
from the humidifiers in percent."
|
|
::= { airIRRP500GroupStatus 9 }
|
|
|
|
airIRRP500GroupStatusHumidifyOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual amount of humidification the group is
|
|
supplying in percent."
|
|
::= { airIRRP500GroupStatus 10 }
|
|
|
|
airIRRP500GroupStatusDehumidifyDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of dehumidification the group is demanding
|
|
from the electric heaters in percent."
|
|
::= { airIRRP500GroupStatus 11 }
|
|
|
|
airIRRP500GroupStatusDehumidifyOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual amount of dehumidification the group is
|
|
supplying in percent."
|
|
::= { airIRRP500GroupStatus 12 }
|
|
|
|
airIRRP500GroupStatusReheatDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of heating the group is demanding
|
|
from the electric heaters in percent."
|
|
::= { airIRRP500GroupStatus 13 }
|
|
|
|
airIRRP500GroupStatusReheatOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual amount of heating the group is
|
|
supplying in percent."
|
|
::= { airIRRP500GroupStatus 14 }
|
|
|
|
|
|
airIRRP500GroupStatusActiveFlowControlStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
under (1),
|
|
okay (2),
|
|
over (3),
|
|
notApplicable (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of the active flow control
|
|
system."
|
|
::= { airIRRP500GroupStatus 15 }
|
|
|
|
airIRRP500GroupStatusDewPointTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group average dew point temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500GroupStatus 16 }
|
|
|
|
airIRRP500GroupStatusDewPointTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group average dew point temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500GroupStatus 17 }
|
|
|
|
|
|
-- airIRRP500 AIR CONDITIONER Group Setpoints
|
|
|
|
airIRRP500GroupSetpointsCoolUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500GroupSetpoints 1 }
|
|
|
|
airIRRP500GroupSetpointsCoolMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500GroupSetpoints 2 }
|
|
|
|
airIRRP500GroupSetpointsSupplyAirUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500GroupSetpoints 3 }
|
|
|
|
airIRRP500GroupSetpointsSupplyAirMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500GroupSetpoints 4 }
|
|
|
|
airIRRP500GroupSetpointsHumidify OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group humidify setpoint in tenths of
|
|
percent relative humidity."
|
|
::= { airIRRP500GroupSetpoints 5 }
|
|
|
|
airIRRP500GroupSetpointsDehumidify OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group dehumidify setpoint in tenths of
|
|
percent relative humidity."
|
|
::= { airIRRP500GroupSetpoints 6 }
|
|
|
|
airIRRP500GroupSetpointsDehumidifyDeadband OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group dehumidify deadband in
|
|
percent relative humidity."
|
|
::= { airIRRP500GroupSetpoints 7 }
|
|
|
|
airIRRP500GroupSetpointsReheatUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500GroupSetpoints 8 }
|
|
|
|
airIRRP500GroupSetpointsReheatMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500GroupSetpoints 9 }
|
|
|
|
airIRRP500GroupSetpointsFanSpeedPreference OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low (1),
|
|
med-low (2),
|
|
med (3),
|
|
med-high (4),
|
|
high (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The preferred fan speed setting."
|
|
::= { airIRRP500GroupSetpoints 10 }
|
|
|
|
airIRRP500GroupSetpointsFanSpeedControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
manual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fan speed control setting."
|
|
::= { airIRRP500GroupSetpoints 11 }
|
|
|
|
airIRRP500GroupSetpointsActiveFlowControlBias OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive (1),
|
|
slightlyPositive (2),
|
|
zero (3),
|
|
slightlyNegative (4),
|
|
negative (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The active flow control bias setting."
|
|
::= { airIRRP500GroupSetpoints 12 }
|
|
|
|
-- airIRRP500 AIR CONDITIONER Group Config
|
|
|
|
airIRRP500GroupConfigNumberofCoolingUnits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of cooling units."
|
|
::= { airIRRP500GroupConfig 1 }
|
|
|
|
airIRRP500GroupConfigConfigurationType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
racs (1),
|
|
hacs (2),
|
|
in-row (3),
|
|
cacs (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group configuration type."
|
|
::= { airIRRP500GroupConfig 2 }
|
|
|
|
airIRRP500GroupConfigPercentGlycol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The glycol mixture in percent."
|
|
::= { airIRRP500GroupConfig 3 }
|
|
|
|
airIRRP500GroupConfigCoolGainP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The gain component of the cool PID in hundredths."
|
|
::= { airIRRP500GroupConfig 4 }
|
|
|
|
airIRRP500GroupConfigCoolResetRateI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The integral component of the cool PID in hundredths."
|
|
::= { airIRRP500GroupConfig 5 }
|
|
|
|
airIRRP500GroupConfigCoolDerivativeD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The derivative component of the cool PID in hundredths."
|
|
::= { airIRRP500GroupConfig 6 }
|
|
|
|
airIRRP500GroupConfigHumidifySensitivityBand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percent relative humidity below the setpoint that
|
|
will cause the humidifier to run at 100% capacity."
|
|
::= { airIRRP500GroupConfig 7 }
|
|
|
|
airIRRP500GroupConfigReheatGainP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The gain component of the reheat PID in hundredths."
|
|
::= { airIRRP500GroupConfig 8 }
|
|
|
|
airIRRP500GroupConfigReheatResetRateI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The integral component of the reheat PID in hundredths."
|
|
::= { airIRRP500GroupConfig 9 }
|
|
|
|
airIRRP500GroupConfigReheatDerivativeD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The derivative component of the reheat PID in hundredths."
|
|
::= { airIRRP500GroupConfig 10 }
|
|
|
|
airIRRP500GroupConfigMaxFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum desired fan speed setting in percent."
|
|
::= { airIRRP500GroupConfig 11 }
|
|
|
|
airIRRP500GroupConfigNumberofBackupUnits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of backup units."
|
|
::= { airIRRP500GroupConfig 12 }
|
|
|
|
airIRRP500GroupConfigRuntimeBalancingEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable runtime balancing feature."
|
|
::= { airIRRP500GroupConfig 13 }
|
|
|
|
airIRRP500GroupConfigLoadAssistEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable load assist feature."
|
|
::= { airIRRP500GroupConfig 14 }
|
|
|
|
airIRRP500GroupConfigFullRPBackups OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of full featured RPs that can be used as backup units."
|
|
::= { airIRRP500GroupConfig 15 }
|
|
|
|
airIRRP500GroupConfigNumberOfActiveFlowControllers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active flow controllers
|
|
present in the group."
|
|
::= { airIRRP500GroupConfig 16 }
|
|
|
|
airIRRP500GroupConfigActiveFlowControllerLampTest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Turns off/on the active flow
|
|
controller lamp test."
|
|
::= { airIRRP500GroupConfig 17 }
|
|
|
|
airIRRP500GroupConfigAltitudeUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group altitude of the units above sea level in feet."
|
|
::= { airIRRP500GroupConfig 18 }
|
|
|
|
airIRRP500GroupConfigAltitudeMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group altitude of the units above sea level in meters."
|
|
::= { airIRRP500GroupConfig 19 }
|
|
|
|
-- airIRRP500 AIR CONDITIONER UNIT Status
|
|
|
|
airIRRP500UnitStatusOperateMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby (1),
|
|
on (2),
|
|
idle (3),
|
|
prestart (4),
|
|
backup (5),
|
|
assist (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cooling unit operating mode."
|
|
::= { airIRRP500UnitStatus 1 }
|
|
|
|
airIRRP500UnitStatusMaximumRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum unit rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500UnitStatus 2 }
|
|
|
|
airIRRP500UnitStatusMaximumRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum unit rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500UnitStatus 3 }
|
|
|
|
airIRRP500UnitStatusSupplyAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit supply air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500UnitStatus 4 }
|
|
|
|
airIRRP500UnitStatusSupplyAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit supply air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500UnitStatus 5 }
|
|
|
|
airIRRP500UnitStatusReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit return air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500UnitStatus 6 }
|
|
|
|
airIRRP500UnitStatusReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit return air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500UnitStatus 7 }
|
|
|
|
airIRRP500UnitStatusSupplyHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative humidity of the supply air in
|
|
tenths of percent."
|
|
::= { airIRRP500UnitStatus 8 }
|
|
|
|
airIRRP500UnitStatusReturnHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative humidity of the return air in
|
|
tenths of percent."
|
|
::= { airIRRP500UnitStatus 9 }
|
|
|
|
airIRRP500UnitStatusAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air flow in cubic feet per minute."
|
|
::= { airIRRP500UnitStatus 10 }
|
|
|
|
airIRRP500UnitStatusAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air flow in hundredths of
|
|
liters per second."
|
|
::= { airIRRP500UnitStatus 11 }
|
|
|
|
airIRRP500UnitStatusFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit average fan speed in tenths of percent."
|
|
::= { airIRRP500UnitStatus 12 }
|
|
|
|
airIRRP500UnitStatusCoolDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit cooling demand in tenths of kiloWatts."
|
|
::= { airIRRP500UnitStatus 13 }
|
|
|
|
airIRRP500UnitStatusCoolOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit cooling output in tenths of kiloWatts."
|
|
::= { airIRRP500UnitStatus 14 }
|
|
|
|
airIRRP500UnitStatusHumidifyDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of humidification the unit is demanding
|
|
from the humidifier in percent."
|
|
::= { airIRRP500UnitStatus 15 }
|
|
|
|
airIRRP500UnitStatusHumidifyOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual humidification output of the unit
|
|
in percent."
|
|
::= { airIRRP500UnitStatus 16 }
|
|
|
|
airIRRP500UnitStatusDehumidifyDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of dehumidification the unit is
|
|
demanding in percent."
|
|
::= { airIRRP500UnitStatus 17 }
|
|
|
|
airIRRP500UnitStatusDehumidifyOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual dehumidification output of the unit
|
|
in percent."
|
|
::= { airIRRP500UnitStatus 18 }
|
|
|
|
airIRRP500UnitStatusReheatDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of heating the unit is demanding
|
|
from the electric heater in percent."
|
|
::= { airIRRP500UnitStatus 19 }
|
|
|
|
airIRRP500UnitStatusReheatOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual heating output of the unit
|
|
in percent."
|
|
::= { airIRRP500UnitStatus 20 }
|
|
|
|
airIRRP500UnitStatusInputState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the input contact."
|
|
::= { airIRRP500UnitStatus 21 }
|
|
|
|
airIRRP500UnitStatusOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the output relay."
|
|
::= { airIRRP500UnitStatus 22 }
|
|
|
|
airIRRP500UnitStatusRackInletTemperature1US OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500UnitStatus 23 }
|
|
|
|
airIRRP500UnitStatusRackInletTemperature1Metric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500UnitStatus 24 }
|
|
|
|
airIRRP500UnitStatusRackInletTemperature2US OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500UnitStatus 25 }
|
|
|
|
airIRRP500UnitStatusRackInletTemperature2Metric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500UnitStatus 26 }
|
|
|
|
airIRRP500UnitStatusRackInletTemperature3US OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRRP500UnitStatus 27 }
|
|
|
|
airIRRP500UnitStatusRackInletTemperature3Metric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature sensor in tenths of
|
|
degrees Celsius."
|
|
::= { airIRRP500UnitStatus 28 }
|
|
|
|
airIRRP500UnitStatusContainmtDPUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit containment differential pressure in
|
|
hundredths of inches of water."
|
|
::= { airIRRP500UnitStatus 29 }
|
|
|
|
airIRRP500UnitStatusContainmtDPMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit containment differential pressure in Pa."
|
|
::= { airIRRP500UnitStatus 30 }
|
|
|
|
airIRRP500UnitStatusFilterDPUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air filter differential pressure in
|
|
hundredths of inches of water."
|
|
::= { airIRRP500UnitStatus 31 }
|
|
|
|
airIRRP500UnitStatusFilterDPMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air filter differential pressure in Pa."
|
|
::= { airIRRP500UnitStatus 32 }
|
|
|
|
airIRRP500UnitStatusHumidifierCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidifier current of the unit
|
|
in tenths of amperes."
|
|
::= { airIRRP500UnitStatus 33 }
|
|
|
|
airIRRP500UnitStatusHumidifierWaterConductivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The water conductivity in the humidifier of the unit
|
|
in microSiemens/cm."
|
|
::= { airIRRP500UnitStatus 34 }
|
|
|
|
airIRRP500UnitStatusActivePowerSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sourceA (1),
|
|
sourceB (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power source that is powering the unit."
|
|
::= { airIRRP500UnitStatus 35 }
|
|
|
|
airIRRP500UnitStatusFluidValvePosition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fluid valve position in percent open."
|
|
::= { airIRRP500UnitStatus 36 }
|
|
|
|
airIRRP500UnitStatusFluidFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fluid flow in tenths of gallons per minute."
|
|
::= { airIRRP500UnitStatus 37 }
|
|
|
|
airIRRP500UnitStatusFluidFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fluid flow in hundredths of liters per second."
|
|
::= { airIRRP500UnitStatus 38 }
|
|
|
|
airIRRP500UnitStatusEnteringFluidTemperatureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the entering fluid in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRP500UnitStatus 39 }
|
|
|
|
airIRRP500UnitStatusEnteringFluidTemperatureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the entering fluid in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRP500UnitStatus 40 }
|
|
|
|
airIRRP500UnitStatusLeavingFluidTemperatureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the Leaving fluid in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRP500UnitStatus 41 }
|
|
|
|
airIRRP500UnitStatusLeavingFluidTemperatureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the Leaving fluid in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRP500UnitStatus 42 }
|
|
|
|
airIRRP500UnitStatusLeakSensor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no-leak (1),
|
|
leak (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state (no-leak/leak) of the leak sensor."
|
|
::= { airIRRP500UnitStatus 43 }
|
|
|
|
|
|
-- airIRRP500 AIR CONDITIONER UNIT Ident
|
|
|
|
airIRRP500UnitIdentID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit identification number."
|
|
::= { airIRRP500UnitIdent 1 }
|
|
|
|
airIRRP500UnitIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit name."
|
|
::= { airIRRP500UnitIdent 2 }
|
|
|
|
airIRRP500UnitIdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit location."
|
|
::= { airIRRP500UnitIdent 3 }
|
|
|
|
airIRRP500UnitIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit model number."
|
|
::= { airIRRP500UnitIdent 4 }
|
|
|
|
airIRRP500UnitIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit serial number."
|
|
::= { airIRRP500UnitIdent 5 }
|
|
|
|
airIRRP500UnitIdentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit firmware version."
|
|
::= { airIRRP500UnitIdent 6 }
|
|
|
|
airIRRP500UnitIdentHardwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit controller hardware revision."
|
|
::= { airIRRP500UnitIdent 7 }
|
|
|
|
airIRRP500UnitIdentManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit manufacture date."
|
|
::= { airIRRP500UnitIdent 8 }
|
|
|
|
|
|
-- airIRRP500 AIR CONDITIONER UNIT Runhours
|
|
|
|
airIRRP500UnitRunHoursAirFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit air filter run hours in hours."
|
|
::= { airIRRP500UnitRunHours 1 }
|
|
|
|
airIRRP500UnitRunHoursCondensatePump OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condensate pump run hours in hours."
|
|
::= { airIRRP500UnitRunHours 2 }
|
|
|
|
airIRRP500UnitRunHoursHumidifier OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan right power supply run hours in hours."
|
|
::= { airIRRP500UnitRunHours 3 }
|
|
|
|
airIRRP500UnitRunHoursFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 1 run hours in hours."
|
|
::= { airIRRP500UnitRunHours 4 }
|
|
|
|
airIRRP500UnitRunHoursHeater1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit heater 1 run hours in hours."
|
|
::= { airIRRP500UnitRunHours 5 }
|
|
|
|
airIRRP500UnitRunHoursFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 2 run hours in hours."
|
|
::= { airIRRP500UnitRunHours 6 }
|
|
|
|
airIRRP500UnitRunHoursHeater2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit Heater 2 run hours in hours."
|
|
::= { airIRRP500UnitRunHours 7 }
|
|
|
|
airIRRP500UnitRunHoursFan3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan 3 run hours in hours."
|
|
::= { airIRRP500UnitRunHours 8 }
|
|
|
|
airIRRP500UnitRunHoursHeater3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit heater 3 run hours in hours."
|
|
::= { airIRRP500UnitRunHours 9 }
|
|
|
|
airIRRP500UnitRunHoursSystem OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total system run hours."
|
|
::= { airIRRP500UnitRunHours 10 }
|
|
|
|
|
|
-- airIRRP500 AIR CONDITIONER UNIT Service Intervals
|
|
|
|
airIRRP500UnitServiceIntervalAirFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Air filter service interval in weeks."
|
|
::= { airIRRP500UnitServiceIntervals 1 }
|
|
|
|
airIRRP500UnitServiceIntervalAirFilterAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The air filter service interval alarm enable/disable."
|
|
::= { airIRRP500UnitServiceIntervals 2 }
|
|
|
|
airIRRP500UnitServiceIntervalHumidifier OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier service interval in weeks."
|
|
::= { airIRRP500UnitServiceIntervals 3 }
|
|
|
|
airIRRP500UnitServiceIntervalHumidifierAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidifier service interval alarm enable/disable."
|
|
::= { airIRRP500UnitServiceIntervals 4 }
|
|
|
|
airIRRP500UnitServiceIntervalHeater OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Heater service interval in weeks."
|
|
::= { airIRRP500UnitServiceIntervals 5 }
|
|
|
|
airIRRP500UnitServiceIntervalHeaterAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The heater service interval alarm enable/disable."
|
|
::= { airIRRP500UnitServiceIntervals 6 }
|
|
|
|
airIRRP500UnitServiceIntervalCondensatePump OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Condensate pump service interval in weeks."
|
|
::= { airIRRP500UnitServiceIntervals 7 }
|
|
|
|
airIRRP500UnitServiceIntervalCondensatePumpAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The condensate pump service interval alarm enable/disable."
|
|
::= { airIRRP500UnitServiceIntervals 8 }
|
|
|
|
airIRRP500UnitServiceIntervalFans OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fans service interval in weeks."
|
|
::= { airIRRP500UnitServiceIntervals 9 }
|
|
|
|
airIRRP500UnitServiceIntervalFansAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fans service interval alarm enable/disable."
|
|
::= { airIRRP500UnitServiceIntervals 10 }
|
|
|
|
|
|
-- airIRRP500 AIR CONDITIONER UNIT Thresholds
|
|
|
|
airIRRP500UnitThresholdsRackInletHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit rack inlet air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRP500UnitThresholds 1 }
|
|
|
|
airIRRP500UnitThresholdsRackInletHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit rack inlet air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRP500UnitThresholds 2 }
|
|
|
|
airIRRP500UnitThresholdsSupplyAirHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air temperature high threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRP500UnitThresholds 3 }
|
|
|
|
airIRRP500UnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air high temperature high threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRP500UnitThresholds 4 }
|
|
|
|
airIRRP500UnitThresholdsReturnAirHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit return air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRP500UnitThresholds 5 }
|
|
|
|
airIRRP500UnitThresholdsReturnAirHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit return air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRP500UnitThresholds 6 }
|
|
|
|
airIRRP500UnitThresholdsSupplyHumidityHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply humidity high threshold in
|
|
tenths of percent relative humidity."
|
|
::= { airIRRP500UnitThresholds 7 }
|
|
|
|
airIRRP500UnitThresholdsSupplyHumidityLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply humidity low threshold in
|
|
tenths of percent relative humidity."
|
|
::= { airIRRP500UnitThresholds 8 }
|
|
|
|
airIRRP500UnitThresholdsEnteringFluidHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering fluid high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRRP500UnitThresholds 9 }
|
|
|
|
airIRRP500UnitThresholdsEnteringFluidHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering fluid high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRRP500UnitThresholds 10 }
|
|
|
|
|
|
-- airIRRP500 AIR CONDITIONER UNIT Config
|
|
|
|
airIRRP500UnitConfigStartupDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The startup delay in seconds."
|
|
::= { airIRRP500UnitConfig 1 }
|
|
|
|
airIRRP500UnitConfigCoolCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
maximum (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cooling capacity options setting."
|
|
::= { airIRRP500UnitConfig 2 }
|
|
|
|
airIRRP500UnitConfigIdleOnLeakDetect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The idle on leak options setting."
|
|
::= { airIRRP500UnitConfig 3 }
|
|
|
|
airIRRP500UnitConfigInputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of the input contact."
|
|
::= { airIRRP500UnitConfig 4 }
|
|
|
|
airIRRP500UnitConfigOutputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of the output relay."
|
|
::= { airIRRP500UnitConfig 5 }
|
|
|
|
airIRRP500UnitConfigOutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
anyAlarm (1),
|
|
criticalAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The source of output relay change."
|
|
::= { airIRRP500UnitConfig 6 }
|
|
|
|
airIRRP500UnitConfigHumidifyEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/disable humidification."
|
|
::= { airIRRP500UnitConfig 7 }
|
|
|
|
airIRRP500UnitConfigHumidifierControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto (1),
|
|
drainOff (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The humidifier drain control."
|
|
::= { airIRRP500UnitConfig 8 }
|
|
|
|
airIRRP500UnitConfigDehumidifyEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/disable dehumidification."
|
|
::= { airIRRP500UnitConfig 9 }
|
|
|
|
airIRRP500UnitConfigReheatEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/disable reheat."
|
|
::= { airIRRP500UnitConfig 10 }
|
|
|
|
airIRRP500UnitConfigHeatAssistEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/disable heat assist."
|
|
::= { airIRRP500UnitConfig 11 }
|
|
|
|
airIRRP500UnitConfigPowerSourceConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
single (1),
|
|
dual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configure the input power source: (1) single feed or (2) dual feed."
|
|
::= { airIRRP500UnitConfig 12 }
|
|
|
|
airIRRP500UnitConfigUnitRoleOverride OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
forcedOn (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When this OID value is (1) automatic, the system determines
|
|
which units are used as primary units and which units are used as backups.
|
|
When this OID value is (2) forcedOn, the connected unit is set as a primary
|
|
unit."
|
|
::= { airIRRP500UnitConfig 13 }
|
|
|
|
airIRRP500UnitConfigSecondaryPowerFeedCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
full (1),
|
|
reduced (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available on chilled water units. When the power source config setting
|
|
is set to dual, setting this value to reduced (2) will inhibit the heater
|
|
and humdifier when the unit is being powered from the secondary
|
|
input."
|
|
::= { airIRRP500UnitConfig 14 }
|
|
|
|
airIRRP500UnitConfigIdleOnCoolFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When this OID value is (1) enable, the unit idles if it detects that it is blowing warm
|
|
air into the cold aisle. The unit will attempt to restart at 5 minute intervals."
|
|
::= { airIRRP500UnitConfig 15 }
|
|
|
|
-- airIRSC AIR CONDITIONER Defines
|
|
|
|
AirIRSCConfigType ::= INTEGER {
|
|
racs (1),
|
|
spot (2),
|
|
in-row (3)
|
|
}
|
|
|
|
AirIRSCCapacityControlType ::= INTEGER {
|
|
discrete (1),
|
|
proportional (2)
|
|
}
|
|
|
|
AirIRSCFanSpeedPreference ::= INTEGER {
|
|
low (1),
|
|
med-low (2),
|
|
med (3),
|
|
med-high (4),
|
|
high (5)
|
|
}
|
|
|
|
AirIRSCFanSpeedControl ::= INTEGER {
|
|
automatic (1),
|
|
manual (2)
|
|
}
|
|
|
|
-- airIRSC AIR CONDITIONER UNIT Status
|
|
|
|
airIRSCUnitStatusOperateMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby (1),
|
|
on (2),
|
|
idle (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cooling unit operating mode."
|
|
::= { airIRSCUnitStatus 1 }
|
|
|
|
airIRSCUnitStatusCoolOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit cooling output in tenths of kW."
|
|
::= { airIRSCUnitStatus 2 }
|
|
|
|
airIRSCUnitStatusCoolDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit cooling demand in tenths of kW."
|
|
::= { airIRSCUnitStatus 3 }
|
|
|
|
airIRSCUnitStatusAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air flow in cubic feet per minute."
|
|
::= { airIRSCUnitStatus 4 }
|
|
|
|
airIRSCUnitStatusAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air flow in liters per second."
|
|
::= { airIRSCUnitStatus 5 }
|
|
|
|
airIRSCUnitStatusRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCUnitStatus 6 }
|
|
|
|
airIRSCUnitStatusRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCUnitStatus 7 }
|
|
|
|
airIRSCUnitStatusSupplyAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit supply air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCUnitStatus 8 }
|
|
|
|
airIRSCUnitStatusSupplyAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit supply air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCUnitStatus 9 }
|
|
|
|
airIRSCUnitStatusReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit return air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCUnitStatus 10 }
|
|
|
|
airIRSCUnitStatusReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit return air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCUnitStatus 11 }
|
|
|
|
airIRSCUnitStatusSuctionTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit suction temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCUnitStatus 12 }
|
|
|
|
airIRSCUnitStatusSuctionTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit suction temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCUnitStatus 13 }
|
|
|
|
airIRSCUnitStatusSuperheatTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit superheat temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCUnitStatus 14 }
|
|
|
|
airIRSCUnitStatusSuperheatTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit superheat temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCUnitStatus 15 }
|
|
|
|
airIRSCUnitStatusContainmtDPUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit containment differential pressure in
|
|
hundredths of inches of water."
|
|
::= { airIRSCUnitStatus 16 }
|
|
|
|
airIRSCUnitStatusContainmtDPMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit containment differential pressure in Pa."
|
|
::= { airIRSCUnitStatus 17 }
|
|
|
|
airIRSCUnitStatusFilterDPUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air filter differential pressure in
|
|
hundredths of inches of water."
|
|
::= { airIRSCUnitStatus 18 }
|
|
|
|
airIRSCUnitStatusFilterDPMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air filter differential pressure in Pa."
|
|
::= { airIRSCUnitStatus 19 }
|
|
|
|
airIRSCUnitStatusSuctionPressureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit suction pressure in pounds per square inch (PSI)."
|
|
::= { airIRSCUnitStatus 20 }
|
|
|
|
airIRSCUnitStatusSuctionPressureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit suction pressure in kiloPascals (kPa)."
|
|
::= { airIRSCUnitStatus 21 }
|
|
|
|
airIRSCUnitStatusDischargePressureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit discharge pressure in pounds per square inch (PSI)."
|
|
::= { airIRSCUnitStatus 22 }
|
|
|
|
airIRSCUnitStatusDischargePressureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit discharge pressure in kiloPascals (kPa)."
|
|
::= { airIRSCUnitStatus 23 }
|
|
|
|
airIRSCUnitStatusEvaporatorFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit average evaporator fan speed in tenths of percent."
|
|
::= { airIRSCUnitStatus 24 }
|
|
|
|
airIRSCUnitStatusCondenserFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit average condenser fan speed in tenths of percent."
|
|
::= { airIRSCUnitStatus 25 }
|
|
|
|
airIRSCUnitStatusInputState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the input contact."
|
|
::= { airIRSCUnitStatus 26 }
|
|
|
|
airIRSCUnitStatusOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the output relay."
|
|
::= { airIRSCUnitStatus 27 }
|
|
|
|
airIRSCUnitStatusCondOutletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit condenser outlet air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCUnitStatus 28 }
|
|
|
|
airIRSCUnitStatusCondOutletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit condenser outlet air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCUnitStatus 29 }
|
|
|
|
airIRSCUnitStatusCondInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit condenser inlet air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCUnitStatus 30 }
|
|
|
|
airIRSCUnitStatusCondInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit condenser inlet air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCUnitStatus 31 }
|
|
|
|
airIRSCUnitStatusCompressor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state (off/on) of the compressor."
|
|
::= { airIRSCUnitStatus 32 }
|
|
|
|
airIRSCUnitStatusLeakSensor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no-leak (1),
|
|
leak (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state (no-leak/leak) of the leak sensor."
|
|
::= { airIRSCUnitStatus 33 }
|
|
|
|
-- airIRSC AIR CONDITIONER UNIT Ident
|
|
|
|
airIRSCUnitIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit name."
|
|
::= { airIRSCUnitIdent 1 }
|
|
|
|
airIRSCUnitIdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit location."
|
|
::= { airIRSCUnitIdent 2 }
|
|
|
|
airIRSCUnitIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit model number."
|
|
::= { airIRSCUnitIdent 3 }
|
|
|
|
airIRSCUnitIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit serial number."
|
|
::= { airIRSCUnitIdent 4 }
|
|
|
|
airIRSCUnitIdentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit firmware version."
|
|
::= { airIRSCUnitIdent 5 }
|
|
|
|
airIRSCUnitIdentHardwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit controller hardware revision."
|
|
::= { airIRSCUnitIdent 6 }
|
|
|
|
airIRSCUnitIdentManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the
|
|
unit manufacture date."
|
|
::= { airIRSCUnitIdent 7 }
|
|
|
|
|
|
-- airIRSC AIR CONDITIONER UNIT Runhours
|
|
|
|
airIRSCUnitRunHoursAirFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit air filter run hours."
|
|
::= { airIRSCUnitRunHours 1 }
|
|
|
|
airIRSCUnitRunHoursEvaporatorFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit evaporator fan 1 run hours."
|
|
::= { airIRSCUnitRunHours 2 }
|
|
|
|
airIRSCUnitRunHoursEvaporatorFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit evaporator fan 2 run hours."
|
|
::= { airIRSCUnitRunHours 3 }
|
|
|
|
airIRSCUnitRunHoursEvaporatorFan3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit evaporator fan 3 run hours."
|
|
::= { airIRSCUnitRunHours 4 }
|
|
|
|
airIRSCUnitRunHoursCondenserFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condenser fan 1 run hours."
|
|
::= { airIRSCUnitRunHours 5 }
|
|
|
|
airIRSCUnitRunHoursCondenserFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condenser fan 2 run hours."
|
|
::= { airIRSCUnitRunHours 6 }
|
|
|
|
airIRSCUnitRunHoursCondenserFan3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condenser fan 3 run hours."
|
|
::= { airIRSCUnitRunHours 7 }
|
|
|
|
airIRSCUnitRunHoursFanPowerSupplyLeft OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan left power supply run hours."
|
|
::= { airIRSCUnitRunHours 8 }
|
|
|
|
airIRSCUnitRunHoursFanPowerSupplyRight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit fan right power supply run hours."
|
|
::= { airIRSCUnitRunHours 9 }
|
|
|
|
airIRSCUnitRunHoursCondensatePump OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condensate pump run hours."
|
|
::= { airIRSCUnitRunHours 10 }
|
|
|
|
airIRSCUnitRunHoursCompressor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit compressor run hours."
|
|
::= { airIRSCUnitRunHours 11 }
|
|
|
|
|
|
-- airIRSC AIR CONDITIONER UNIT Service Intervals
|
|
|
|
airIRSCUnitServiceIntervalsAirFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Air filter service interval in weeks."
|
|
::= { airIRSCUnitServiceIntervals 1 }
|
|
|
|
airIRSCUnitServiceIntervalsAirFilterAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The air filter service interval alarm enable/disable."
|
|
::= { airIRSCUnitServiceIntervals 2 }
|
|
|
|
|
|
-- airIRSC AIR CONDITIONER UNIT Thresholds
|
|
|
|
airIRSCUnitThresholdsRackInletHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit rack inlet air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRSCUnitThresholds 1 }
|
|
|
|
airIRSCUnitThresholdsRackInletHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit rack inlet air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRSCUnitThresholds 2 }
|
|
|
|
airIRSCUnitThresholdsSupplyAirHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRSCUnitThresholds 3 }
|
|
|
|
airIRSCUnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRSCUnitThresholds 4 }
|
|
|
|
airIRSCUnitThresholdsReturnAirHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit return air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRSCUnitThresholds 5 }
|
|
|
|
airIRSCUnitThresholdsReturnAirHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit return air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRSCUnitThresholds 6 }
|
|
|
|
-- airIRSC AIR CONDITIONER UNIT Setpoints
|
|
|
|
airIRSCUnitSetptsCoolSetpointUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit cooling setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCUnitSetpoints 1 }
|
|
|
|
airIRSCUnitSetptsCoolSetpointMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit cooling setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCUnitSetpoints 2 }
|
|
|
|
airIRSCUnitSetptsCoolDeadbandUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit cooling deadband in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCUnitSetpoints 3 }
|
|
|
|
airIRSCUnitSetptsCoolDeadbandMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit cooling deadband in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCUnitSetpoints 4 }
|
|
|
|
airIRSCUnitSetptsFanSpeedPreference OBJECT-TYPE
|
|
SYNTAX AirIRSCFanSpeedPreference
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The preferred fan speed setting."
|
|
::= { airIRSCUnitSetpoints 5 }
|
|
|
|
airIRSCUnitSetptsSupplyAirSetpointUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCUnitSetpoints 6 }
|
|
|
|
airIRSCUnitSetptsSupplyAirSetpointMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCUnitSetpoints 7 }
|
|
|
|
-- airIRSC AIR CONDITIONER UNIT Config
|
|
|
|
airIRSCUnitConfigConfigurationType OBJECT-TYPE
|
|
SYNTAX AirIRSCConfigType
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit configuration type."
|
|
::= { airIRSCUnitConfig 1 }
|
|
|
|
airIRSCUnitConfigCapacityControlType OBJECT-TYPE
|
|
SYNTAX AirIRSCCapacityControlType
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit capacity control."
|
|
::= { airIRSCUnitConfig 2 }
|
|
|
|
airIRSCUnitConfigStartupDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The startup delay in seconds."
|
|
::= { airIRSCUnitConfig 3 }
|
|
|
|
airIRSCUnitConfigIdleOnLeakDetect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The idle on leak options setting."
|
|
::= { airIRSCUnitConfig 4 }
|
|
|
|
airIRSCUnitConfigInputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of the input contact."
|
|
::= { airIRSCUnitConfig 5 }
|
|
|
|
airIRSCUnitConfigOutputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of the output relay."
|
|
::= { airIRSCUnitConfig 6 }
|
|
|
|
airIRSCUnitConfigOutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
anyAlarm (1),
|
|
criticalAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The source of output relay change."
|
|
::= { airIRSCUnitConfig 7 }
|
|
|
|
airIRSCUnitConfigAltitudeUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The altitude of the unit above sea level in feet."
|
|
::= { airIRSCUnitConfig 8 }
|
|
|
|
airIRSCUnitConfigAltitudeMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The altitude of the unit above sea level in meters."
|
|
::= { airIRSCUnitConfig 9 }
|
|
|
|
airIRSCUnitConfigOpControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit operational control."
|
|
::= { airIRSCUnitConfig 10 }
|
|
|
|
|
|
-- airIRSC AIR CONDITIONER GROUP Status
|
|
|
|
airIRSCGroupStatusCoolOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group cooling output in tenths of kW."
|
|
::= { airIRSCGroupStatus 1 }
|
|
|
|
airIRSCGroupStatusCoolDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group cooling demand in tenths of kW."
|
|
::= { airIRSCGroupStatus 2 }
|
|
|
|
airIRSCGroupStatusAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group air flow in cubic feet per minute."
|
|
::= { airIRSCGroupStatus 3 }
|
|
|
|
airIRSCGroupStatusAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group air flow in liters per second."
|
|
::= { airIRSCGroupStatus 4 }
|
|
|
|
airIRSCGroupStatusMaxRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCGroupStatus 5 }
|
|
|
|
airIRSCGroupStatusMaxRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCGroupStatus 6 }
|
|
|
|
airIRSCGroupStatusMinRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCGroupStatus 7 }
|
|
|
|
airIRSCGroupStatusMinRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCGroupStatus 8 }
|
|
|
|
airIRSCGroupStatusMaxReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum return air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCGroupStatus 9 }
|
|
|
|
airIRSCGroupStatusMaxReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum return air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCGroupStatus 10 }
|
|
|
|
airIRSCGroupStatusMinReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum return air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCGroupStatus 11 }
|
|
|
|
airIRSCGroupStatusMinReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum return air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCGroupStatus 12 }
|
|
|
|
airIRSCGroupStatusActiveFlowControlStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
under (1),
|
|
okay (2),
|
|
over (3),
|
|
notApplicable (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of the active flow control
|
|
system."
|
|
::= { airIRSCGroupStatus 13 }
|
|
|
|
|
|
-- airIRSC AIR CONDITIONER GROUP Setpoint
|
|
|
|
airIRSCGroupSetptsCoolSetpointUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCGroupSetpoints 1 }
|
|
|
|
airIRSCGroupSetptsCoolSetpointMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCGroupSetpoints 2 }
|
|
|
|
airIRSCGroupSetptsCoolDeadbandUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling deadband in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCGroupSetpoints 3 }
|
|
|
|
airIRSCGroupSetptsCoolDeadbandMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling deadband in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCGroupSetpoints 4 }
|
|
|
|
airIRSCGroupSetptsFanSpeedPreference OBJECT-TYPE
|
|
SYNTAX AirIRSCFanSpeedPreference
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group preferred fan speed setting."
|
|
::= { airIRSCGroupSetpoints 5 }
|
|
|
|
airIRSCGroupSetptsSupplyAirSetpointUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRSCGroupSetpoints 6 }
|
|
|
|
airIRSCGroupSetptsSupplyAirSetpointMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRSCGroupSetpoints 7 }
|
|
|
|
airIRSCGroupSetpointsActiveFlowControlBias OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive (1),
|
|
slightlyPositive (2),
|
|
zero (3),
|
|
slightlyNegative (4),
|
|
negative (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The active flow control bias setting."
|
|
::= { airIRSCGroupSetpoints 8 }
|
|
|
|
-- airIRSC AIR CONDITIONER GROUP Config
|
|
|
|
airIRSCGroupConfigNumberofCoolingUnits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of cooling units."
|
|
::= { airIRSCGroupConfig 1 }
|
|
|
|
airIRSCGroupConfigConfigurationType OBJECT-TYPE
|
|
SYNTAX AirIRSCConfigType
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group configuration type."
|
|
::= { airIRSCGroupConfig 2 }
|
|
|
|
airIRSCGroupConfigCapacityControlType OBJECT-TYPE
|
|
SYNTAX AirIRSCCapacityControlType
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group capacity control."
|
|
::= { airIRSCGroupConfig 3 }
|
|
|
|
airIRSCGroupConfigAltitudeUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group altitude of the units above sea level in feet."
|
|
::= { airIRSCGroupConfig 4 }
|
|
|
|
airIRSCGroupConfigAltitudeMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group altitude of the units above sea level in meters."
|
|
::= { airIRSCGroupConfig 5 }
|
|
|
|
airIRSCGroupConfigFanSpeedControl OBJECT-TYPE
|
|
SYNTAX AirIRSCFanSpeedControl
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group fan speed control."
|
|
::= { airIRSCGroupConfig 6 }
|
|
|
|
airIRSCGroupConfigNumberOfActiveFlowControllers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active flow controllers
|
|
present in the group."
|
|
::= { airIRSCGroupConfig 7 }
|
|
|
|
airIRSCGroupConfigActiveFlowControllerLampTest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Turns off/on the active flow
|
|
controller lamp test."
|
|
::= { airIRSCGroupConfig 8 }
|
|
|
|
-- ******************************************************************
|
|
-- airIRG2 Ident
|
|
-- ******************************************************************
|
|
|
|
airIRG2IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit name."
|
|
::= { airIRG2Ident 1 }
|
|
|
|
airIRG2IdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit location."
|
|
::= { airIRG2Ident 2 }
|
|
|
|
airIRG2IdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit model number."
|
|
::= { airIRG2Ident 3 }
|
|
|
|
airIRG2IdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit serial number."
|
|
::= { airIRG2Ident 4 }
|
|
|
|
airIRG2IdentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit firmware version."
|
|
::= { airIRG2Ident 5 }
|
|
|
|
airIRG2IdentHardwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit controller hardware revision."
|
|
::= { airIRG2Ident 6 }
|
|
|
|
airIRG2IdentManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit manufacture date."
|
|
::= { airIRG2Ident 7 }
|
|
|
|
airIRG2IdentUnitSysOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID contains an OID path to the device's top level unit data."
|
|
::= { airIRG2Ident 8 }
|
|
|
|
airIRG2IdentGroupSysOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID contains an OID path to the device's top level group data."
|
|
::= { airIRG2Ident 9 }
|
|
|
|
-- ******************************************************************
|
|
-- airIRG2 GROUP Status
|
|
-- ******************************************************************
|
|
|
|
airIRG2GroupStatusCoolOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group cooling output in tenths of kilowatts (kW)."
|
|
::= { airIRG2GroupStatus 1 }
|
|
|
|
airIRG2GroupStatusCoolDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group cooling demand in tenths of kilowatts (kW)."
|
|
::= { airIRG2GroupStatus 2 }
|
|
|
|
airIRG2GroupStatusAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group air flow in cubic feet per minute."
|
|
::= { airIRG2GroupStatus 3 }
|
|
|
|
airIRG2GroupStatusAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group air flow in hundredths of
|
|
liters per second."
|
|
::= { airIRG2GroupStatus 4 }
|
|
|
|
airIRG2GroupStatusMaxRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2GroupStatus 5 }
|
|
|
|
airIRG2GroupStatusMaxRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2GroupStatus 6 }
|
|
|
|
airIRG2GroupStatusMinRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2GroupStatus 7 }
|
|
|
|
airIRG2GroupStatusMinRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2GroupStatus 8 }
|
|
|
|
airIRG2GroupStatusMaxReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum return air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2GroupStatus 9 }
|
|
|
|
airIRG2GroupStatusMaxReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum return air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2GroupStatus 10 }
|
|
|
|
airIRG2GroupStatusMinReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum return air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2GroupStatus 11 }
|
|
|
|
airIRG2GroupStatusMinReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum return air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2GroupStatus 12 }
|
|
|
|
airIRG2GroupStatusActiveFlowControlStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
under (1),
|
|
okay (2),
|
|
over (3),
|
|
notApplicable (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of the active flow control
|
|
system."
|
|
::= { airIRG2GroupStatus 13 }
|
|
|
|
|
|
-- ******************************************************************
|
|
-- airIRG2 GROUP Setpoint
|
|
-- ******************************************************************
|
|
|
|
airIRG2GroupSetptsCoolSetpointUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2GroupSetpoints 1 }
|
|
|
|
airIRG2GroupSetptsCoolSetpointMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2GroupSetpoints 2 }
|
|
|
|
airIRG2GroupSetptsCoolDeadbandUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling deadband in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2GroupSetpoints 3 }
|
|
|
|
airIRG2GroupSetptsCoolDeadbandMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling deadband in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2GroupSetpoints 4 }
|
|
|
|
airIRG2GroupSetptsFanSpeedPreference OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low (1),
|
|
med-low (2),
|
|
med (3),
|
|
med-high (4),
|
|
high (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group preferred fan speed setting."
|
|
::= { airIRG2GroupSetpoints 5 }
|
|
|
|
airIRG2GroupSetptsSupplyAirSetpointUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2GroupSetpoints 6 }
|
|
|
|
airIRG2GroupSetptsSupplyAirSetpointMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2GroupSetpoints 7 }
|
|
|
|
airIRG2GroupSetpointsActiveFlowControlBias OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive (1),
|
|
slightlyPositive (2),
|
|
zero (3),
|
|
slightlyNegative (4),
|
|
negative (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The active flow control bias setting."
|
|
::= { airIRG2GroupSetpoints 8 }
|
|
|
|
-- ******************************************************************
|
|
-- airIRG2 GROUP Config
|
|
-- ******************************************************************
|
|
airIRG2GroupConfigNumberofCoolingUnits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of cooling units."
|
|
::= { airIRG2GroupConfig 1 }
|
|
|
|
airIRG2GroupConfigConfigurationType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
racs (1),
|
|
spot (2),
|
|
in-row (3),
|
|
hacs (4),
|
|
cacs (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group configuration type."
|
|
::= { airIRG2GroupConfig 2 }
|
|
|
|
airIRG2GroupConfigCapacityControlType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
discrete (1),
|
|
proportional (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group capacity control."
|
|
::= { airIRG2GroupConfig 3 }
|
|
|
|
airIRG2GroupConfigFanSpeedControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
manual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group fan speed control."
|
|
::= { airIRG2GroupConfig 4 }
|
|
|
|
airIRG2GroupConfigCoolGainP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The gain component of the PID in hundredths."
|
|
::= { airIRG2GroupConfig 5 }
|
|
|
|
airIRG2GroupConfigCoolResetRateI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The integral component of the PID in hundredths."
|
|
::= { airIRG2GroupConfig 6 }
|
|
|
|
airIRG2GroupConfigCoolDerivativeD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The derivative component of the PID in hundredths."
|
|
::= { airIRG2GroupConfig 7 }
|
|
|
|
airIRG2GroupConfigCoolPIDReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
readBack (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Will reset the PID coefficients back to the factory defaults."
|
|
::= { airIRG2GroupConfig 8 }
|
|
|
|
airIRG2GroupConfigNumberofBackupUnits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of backup units."
|
|
::= { airIRG2GroupConfig 9 }
|
|
|
|
airIRG2GroupConfigRuntimeBalancingEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable runtime balancing feature."
|
|
::= { airIRG2GroupConfig 10 }
|
|
|
|
airIRG2GroupConfigLoadAssistEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable load assist feature."
|
|
::= { airIRG2GroupConfig 11 }
|
|
|
|
airIRG2GroupConfigNumberOfActiveFlowControllers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active flow controllers
|
|
present in the group."
|
|
::= { airIRG2GroupConfig 12 }
|
|
|
|
airIRG2GroupConfigActiveFlowControllerLampTest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Turns off/on the active flow
|
|
controller lamp test."
|
|
::= { airIRG2GroupConfig 13 }
|
|
|
|
airIRG2GroupConfigAltitudeUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group altitude of the units above sea level in feet."
|
|
::= { airIRG2GroupConfig 14 }
|
|
|
|
airIRG2GroupConfigAltitudeMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group altitude of the units above sea level in meters."
|
|
::= { airIRG2GroupConfig 15 }
|
|
|
|
-- ***************************************
|
|
-- airIRG2 Alarm Status
|
|
-- ***************************************
|
|
|
|
airIRG2AlarmsTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active alarms in the airIRG2AlarmsTable."
|
|
::= { airIRG2Alarms 1 }
|
|
|
|
AirIRG2AlarmsEntry ::= SEQUENCE {
|
|
airIRG2AlarmsIndex INTEGER,
|
|
airIRG2AlarmsEventCode INTEGER,
|
|
airIRG2AlarmsDescription DisplayString
|
|
}
|
|
|
|
airIRG2AlarmsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG2AlarmsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of active alarms for the device."
|
|
::= { airIRG2Alarms 2 }
|
|
|
|
airIRG2AlarmsEntry OBJECT-TYPE
|
|
SYNTAX AirIRG2AlarmsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarms specification"
|
|
INDEX { airIRG2AlarmsIndex }
|
|
::= { airIRG2AlarmsTable 1 }
|
|
|
|
airIRG2AlarmsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm index."
|
|
::= { airIRG2AlarmsEntry 1 }
|
|
|
|
airIRG2AlarmsEventCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Code for the alarm."
|
|
::= { airIRG2AlarmsEntry 2 }
|
|
|
|
airIRG2AlarmsDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the alarm."
|
|
::= { airIRG2AlarmsEntry 3 }
|
|
|
|
-- ***************************************
|
|
-- airIRG2RDType2 AIR CONDITIONER Defines
|
|
-- ***************************************
|
|
|
|
AirIRG2RDType2IOState ::= INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
|
|
-- ******************************************************************
|
|
-- airIRG2RDT2 Status
|
|
-- ******************************************************************
|
|
|
|
airIRG2RDT2StatusOperateMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby (1),
|
|
on (2),
|
|
idle (3),
|
|
reserved (4),
|
|
service (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cooling unit operating mode."
|
|
::= { airIRG2RDT2Status 1 }
|
|
|
|
airIRG2RDT2StatusCoolOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit cooling output in tenths of kilowatts (kW)."
|
|
::= { airIRG2RDT2Status 2 }
|
|
|
|
airIRG2RDT2StatusCoolDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit cooling demand in tenths of kilowatts (kW)."
|
|
::= { airIRG2RDT2Status 3 }
|
|
|
|
airIRG2RDT2StatusAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air flow in cubic feet per minute."
|
|
::= { airIRG2RDT2Status 4 }
|
|
|
|
airIRG2RDT2StatusAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air flow in liters per second."
|
|
::= { airIRG2RDT2Status 5 }
|
|
|
|
airIRG2RDT2StatusRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2RDT2Status 6 }
|
|
|
|
airIRG2RDT2StatusRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2RDT2Status 7 }
|
|
|
|
airIRG2RDT2StatusSupplyAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit supply air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2RDT2Status 8 }
|
|
|
|
airIRG2RDT2StatusSupplyAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit supply air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2RDT2Status 9 }
|
|
|
|
airIRG2RDT2StatusReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit return air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2RDT2Status 10 }
|
|
|
|
airIRG2RDT2StatusReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit return air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2RDT2Status 11 }
|
|
|
|
airIRG2RDT2StatusSuctionTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit suction temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2RDT2Status 12 }
|
|
|
|
airIRG2RDT2StatusSuctionTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit suction temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2RDT2Status 13 }
|
|
|
|
airIRG2RDT2StatusSuperheatTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit superheat temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG2RDT2Status 14 }
|
|
|
|
airIRG2RDT2StatusSuperheatTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit superheat temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG2RDT2Status 15 }
|
|
|
|
airIRG2RDT2StatusFilterDPUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air filter differential pressure in
|
|
hundredths of inches of water."
|
|
::= { airIRG2RDT2Status 16 }
|
|
|
|
airIRG2RDT2StatusFilterDPMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit air filter differential pressure in pascals (Pa)."
|
|
::= { airIRG2RDT2Status 17 }
|
|
|
|
airIRG2RDT2StatusSuctionPressureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit suction pressure in pounds per square inch (PSI)."
|
|
::= { airIRG2RDT2Status 18 }
|
|
|
|
airIRG2RDT2StatusSuctionPressureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit suction pressure in kiloPascals (kPa)."
|
|
::= { airIRG2RDT2Status 19 }
|
|
|
|
airIRG2RDT2StatusDischargePressureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit discharge pressure in pounds per square inch (PSI)."
|
|
::= { airIRG2RDT2Status 20 }
|
|
|
|
airIRG2RDT2StatusDischargePressureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit discharge pressure in kiloPascals (kPa)."
|
|
::= { airIRG2RDT2Status 21 }
|
|
|
|
airIRG2RDT2StatusEvaporatorFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit average evaporator fan speed in tenths of percent."
|
|
::= { airIRG2RDT2Status 22 }
|
|
|
|
airIRG2RDT2StatusInputState OBJECT-TYPE
|
|
SYNTAX AirIRG2RDType2IOState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the input contact."
|
|
::= { airIRG2RDT2Status 23 }
|
|
|
|
airIRG2RDT2StatusOutputState OBJECT-TYPE
|
|
SYNTAX AirIRG2RDType2IOState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the output relay."
|
|
::= { airIRG2RDT2Status 24 }
|
|
|
|
airIRG2RDT2StatusOHEInputState OBJECT-TYPE
|
|
SYNTAX AirIRG2RDType2IOState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the outside heat exchanger(OHE) input contact."
|
|
::= { airIRG2RDT2Status 25 }
|
|
|
|
airIRG2RDT2StatusOHEOutputState OBJECT-TYPE
|
|
SYNTAX AirIRG2RDType2IOState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the outside heat exchanger(OHE) output relay."
|
|
::= { airIRG2RDT2Status 26 }
|
|
|
|
airIRG2RDT2StatusCompressor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state (off/on) of the compressor."
|
|
::= { airIRG2RDT2Status 27 }
|
|
|
|
airIRG2RDT2StatusFluidValvePos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The position of the fluid valve in percent. This OID is only valid
|
|
when airIRG2RDT2ConfigUnitType indicates fluidCooled(1)."
|
|
::= { airIRG2RDT2Status 28 }
|
|
|
|
airIRG2RDT2StatusHotGasBypassValvePos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The position of the hot gas bypass valve in hundredths of percent."
|
|
::= { airIRG2RDT2Status 29 }
|
|
|
|
airIRG2RDT2StatusLeakSensor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no-leak (1),
|
|
leak (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state (no-leak/leak) of the leak sensor."
|
|
::= { airIRG2RDT2Status 30 }
|
|
|
|
-- ******************************************************************
|
|
-- airIRG2RDT2 Runhours
|
|
-- ******************************************************************
|
|
|
|
airIRG2RDT2RunHoursAirFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit air filter run hours."
|
|
::= { airIRG2RDT2RunHours 1 }
|
|
|
|
airIRG2RDT2RunHoursCondensatePump OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condensate pump run hours."
|
|
::= { airIRG2RDT2RunHours 2 }
|
|
|
|
airIRG2RDT2RunHoursCompressor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit compressor run hours."
|
|
::= { airIRG2RDT2RunHours 3 }
|
|
|
|
-- *******************************
|
|
-- Run Hour Fan Power supply table
|
|
-- *******************************
|
|
airIRG2RDT2RunHoursFanPSTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the run hour fan power supply table
|
|
(airIRG2RDT2RunHoursFanPSTable)."
|
|
::= { airIRG2RDT2RunHours 4 }
|
|
|
|
AirIRG2RDT2RunHoursFanPSEntry ::=
|
|
SEQUENCE {
|
|
airIRG2RDT2RunHoursFanPSIndex INTEGER,
|
|
airIRG2RDT2RunHoursFanPSPosition INTEGER,
|
|
airIRG2RDT2RunHoursFanPSHours INTEGER
|
|
}
|
|
|
|
airIRG2RDT2RunHoursFanPSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG2RDT2RunHoursFanPSEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting run hour information from each power supply."
|
|
::= { airIRG2RDT2RunHours 5 }
|
|
|
|
airIRG2RDT2RunHoursFanPSEntry OBJECT-TYPE
|
|
SYNTAX AirIRG2RDT2RunHoursFanPSEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The run hours fan power supply table entry."
|
|
INDEX { airIRG2RDT2RunHoursFanPSIndex }
|
|
::= { airIRG2RDT2RunHoursFanPSTable 1 }
|
|
|
|
airIRG2RDT2RunHoursFanPSIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of run hours fan power supply table."
|
|
::= { airIRG2RDT2RunHoursFanPSEntry 1 }
|
|
|
|
airIRG2RDT2RunHoursFanPSHours OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan power supply run time in hours."
|
|
::= { airIRG2RDT2RunHoursFanPSEntry 2 }
|
|
|
|
airIRG2RDT2RunHoursFanPSPosition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
upper (1),
|
|
lower (2),
|
|
left (3),
|
|
right (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Position of fan power supply within the unit."
|
|
::= { airIRG2RDT2RunHoursFanPSEntry 3 }
|
|
|
|
-- *****************************
|
|
-- Run Hour Evaporator Fan table
|
|
-- *****************************
|
|
airIRG2RDT2RunHoursEvapFanTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the run hour evaporator fan table
|
|
(airIRG2RDT2RunHoursEvapFanTable)."
|
|
::= { airIRG2RDT2RunHours 6 }
|
|
|
|
AirIRG2RDT2RunHoursEvapFanEntry ::=
|
|
SEQUENCE {
|
|
airIRG2RDT2RunHoursEvapFanIndex INTEGER,
|
|
airIRG2RDT2RunHoursEvapFanHours INTEGER
|
|
}
|
|
|
|
airIRG2RDT2RunHoursEvapFanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG2RDT2RunHoursEvapFanEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each evaporator fan run
|
|
hour in the system. "
|
|
::= { airIRG2RDT2RunHours 7 }
|
|
|
|
airIRG2RDT2RunHoursEvapFanEntry OBJECT-TYPE
|
|
SYNTAX AirIRG2RDT2RunHoursEvapFanEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information from each evaporator fan run
|
|
hour in the system. "
|
|
INDEX { airIRG2RDT2RunHoursEvapFanIndex }
|
|
::= { airIRG2RDT2RunHoursEvapFanTable 1 }
|
|
|
|
airIRG2RDT2RunHoursEvapFanIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of run hours evaporator fan table."
|
|
::= { airIRG2RDT2RunHoursEvapFanEntry 1 }
|
|
|
|
airIRG2RDT2RunHoursEvapFanHours OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Evaporator fan run time in hours."
|
|
::= { airIRG2RDT2RunHoursEvapFanEntry 2 }
|
|
|
|
airIRG2RDT2RunHoursUnit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit run time in hours."
|
|
::= { airIRG2RDT2RunHours 8 }
|
|
|
|
-- ******************************************************************
|
|
-- airIRG2RDT2 Service Intervals
|
|
-- ******************************************************************
|
|
|
|
airIRG2RDT2ServiceIntervalsAirFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Air filter service interval in weeks."
|
|
::= { airIRG2RDT2ServiceIntervals 1 }
|
|
|
|
airIRG2RDT2ServiceIntervalsAirFilterAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The air filter service interval alarm enable/disable."
|
|
::= { airIRG2RDT2ServiceIntervals 2 }
|
|
|
|
-- ******************************************************************
|
|
-- airIRG2RDT2 Thresholds
|
|
-- ******************************************************************
|
|
|
|
airIRG2RDT2ThresholdsRackInletHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit rack inlet air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRG2RDT2Thresholds 1 }
|
|
|
|
airIRG2RDT2ThresholdsRackInletHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit rack inlet air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRG2RDT2Thresholds 2 }
|
|
|
|
airIRG2RDT2ThresholdsSupplyAirHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRG2RDT2Thresholds 3 }
|
|
|
|
airIRG2RDT2ThresholdsSupplyAirHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit supply air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRG2RDT2Thresholds 4 }
|
|
|
|
airIRG2RDT2ThresholdsReturnAirHighTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit return air high temperature threshold in
|
|
tenths of degrees Fahrenheit."
|
|
::= { airIRG2RDT2Thresholds 5 }
|
|
|
|
airIRG2RDT2ThresholdsReturnAirHighTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit return air high temperature threshold in
|
|
tenths of degrees Celsius."
|
|
::= { airIRG2RDT2Thresholds 6 }
|
|
|
|
-- ******************************************************************
|
|
-- airIRG2RDT2 Setpoints
|
|
-- ******************************************************************
|
|
|
|
-- There are no setpoint OIDs. This is just a placeholder in case
|
|
-- we add some unit setpoints.
|
|
|
|
-- ******************************************************************
|
|
-- airIRG2RDT2 Config
|
|
-- ******************************************************************
|
|
|
|
airIRG2RDT2ConfigUnitType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fluidCooled (1),
|
|
airCooled (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the unit."
|
|
::= { airIRG2RDT2Config 1 }
|
|
|
|
airIRG2RDT2ConfigStartupDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The startup delay in seconds."
|
|
::= { airIRG2RDT2Config 2 }
|
|
|
|
airIRG2RDT2ConfigIdleOnLeakDetect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The idle on leak options setting."
|
|
::= { airIRG2RDT2Config 3 }
|
|
|
|
airIRG2RDT2ConfigInputNormalState OBJECT-TYPE
|
|
SYNTAX AirIRG2RDType2IOState
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of the input contact."
|
|
::= { airIRG2RDT2Config 4 }
|
|
|
|
airIRG2RDT2ConfigOutputNormalState OBJECT-TYPE
|
|
SYNTAX AirIRG2RDType2IOState
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of the output relay."
|
|
::= { airIRG2RDT2Config 5 }
|
|
|
|
airIRG2RDT2ConfigOutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
anyAlarm (1),
|
|
criticalAlarm (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The source of output relay change."
|
|
::= { airIRG2RDT2Config 6 }
|
|
|
|
airIRG2RDT2ConfigOHEInputNormalState OBJECT-TYPE
|
|
SYNTAX AirIRG2RDType2IOState
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of the outside heat exchanger(OHE) input relay."
|
|
::= { airIRG2RDT2Config 7 }
|
|
|
|
airIRG2RDT2ConfigUnitRoleOverride OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
forcedOn (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When this OID value is (1) automatic, the system determines
|
|
which units are used as primary units and which units are used as backups.
|
|
When this OID value is (2) forcedOn, the connected unit is set as a primary
|
|
unit."
|
|
::= { airIRG2RDT2Config 8 }
|
|
|
|
airIRG2RDT2ConfigUnitIdleOnCoolFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When this OID value is (2) yes, the unit idles if it detects that it is blowing warm
|
|
air into the cold aisle. The unit will attempt to restart at 5 minute intervals."
|
|
::= { airIRG2RDT2Config 9 }
|
|
|
|
-- Beginning of AC InRoom
|
|
|
|
-- common InRoom values
|
|
AirIRmAlarmState ::= INTEGER { ok (1), alarm (2) }
|
|
AirIRmControlState ::= INTEGER { off (1), on (2) }
|
|
AirIRmStopState ::= INTEGER { maybeOn (1), unitOff (2) }
|
|
AirIRmActivityState ::= INTEGER { inactive (1), active (2) }
|
|
|
|
|
|
-- ***************************************
|
|
-- InRoom Ident
|
|
-- ***************************************
|
|
|
|
airIRmIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit name."
|
|
::= { airIRmIdent 1 }
|
|
|
|
airIRmIdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit location."
|
|
::= { airIRmIdent 2 }
|
|
|
|
airIRmIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit model number."
|
|
::= { airIRmIdent 3 }
|
|
|
|
airIRmIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit serial number."
|
|
::= { airIRmIdent 4 }
|
|
|
|
airIRmIdentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit firmware version."
|
|
::= { airIRmIdent 5 }
|
|
|
|
airIRmIdentHardwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit controller hardware revision."
|
|
::= { airIRmIdent 6 }
|
|
|
|
airIRmIdentManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit manufacture date."
|
|
::= { airIRmIdent 7 }
|
|
|
|
airIRmIdentSysOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID contains an OID path to the device's top level data."
|
|
::= { airIRmIdent 8 }
|
|
|
|
-- ***************************************
|
|
-- InRoom Alarm Status
|
|
-- ***************************************
|
|
|
|
airIRmAlarmsTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active alarms in the airIRG2AlarmsTable."
|
|
::= { airIRmAlarms 1 }
|
|
|
|
AirIRmAlarmsEntry ::= SEQUENCE {
|
|
airIRmAlarmsIndex INTEGER,
|
|
airIRmAlarmsEventCode INTEGER,
|
|
airIRmAlarmsDescription DisplayString
|
|
}
|
|
|
|
airIRmAlarmsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRmAlarmsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of active alarms for the device."
|
|
::= { airIRmAlarms 2 }
|
|
|
|
airIRmAlarmsEntry OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarms specification"
|
|
INDEX { airIRmAlarmsIndex }
|
|
::= { airIRmAlarmsTable 1 }
|
|
|
|
airIRmAlarmsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm index."
|
|
::= { airIRmAlarmsEntry 1 }
|
|
|
|
airIRmAlarmsEventCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Code for the alarm."
|
|
::= { airIRmAlarmsEntry 2 }
|
|
|
|
airIRmAlarmsDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the alarm."
|
|
::= { airIRmAlarmsEntry 3 }
|
|
|
|
|
|
-- airIRmPmCommon1
|
|
|
|
airIRmPmUnitType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mc (1),
|
|
dx (2),
|
|
cw (3),
|
|
ch (4),
|
|
ecoCool (5),
|
|
msc (6),
|
|
ge1 (7),
|
|
ge2 (8),
|
|
dualFluid (9),
|
|
cw2 (10),
|
|
unknown (256) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit type (1)."
|
|
::= { airIRmPmCommon1 1 }
|
|
|
|
airIRmPmSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Software version (3)."
|
|
::= { airIRmPmCommon1 3 }
|
|
|
|
airIRmPmBusAddress OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bus addresss of unit (5)."
|
|
::= { airIRmPmCommon1 5 }
|
|
|
|
airIRmPmControllerType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
c4000 (2),
|
|
c1001 (3),
|
|
c1002 (4),
|
|
c5000 (5),
|
|
c6000 (6),
|
|
c1010 (7),
|
|
c7000IOC (8),
|
|
c7000AT (9),
|
|
c7000PT (10),
|
|
c5MSC (11),
|
|
c7000PT2 (12) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Controller type (7)."
|
|
::= { airIRmPmCommon1 7 }
|
|
|
|
airIRmPmGeneralError OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"General Error (8)"
|
|
::= { airIRmPmCommon1 8 }
|
|
|
|
airIRmPmErrorOnBus OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error On Bus (9)"
|
|
::= { airIRmPmCommon1 9 }
|
|
|
|
-- airIRmPmCommon2
|
|
|
|
airIRmPmPCStop OBJECT-TYPE
|
|
SYNTAX AirIRmStopState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PC-STOP (1000)"
|
|
::= { airIRmPmCommon2 1 }
|
|
|
|
airIRmPmRemoteStop OBJECT-TYPE
|
|
SYNTAX AirIRmStopState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote Stop (1001)"
|
|
::= { airIRmPmCommon2 2 }
|
|
|
|
airIRmPmLocalStop OBJECT-TYPE
|
|
SYNTAX AirIRmStopState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local Stop (1002)"
|
|
::= { airIRmPmCommon2 3}
|
|
|
|
airIRmPmTimerStop OBJECT-TYPE
|
|
SYNTAX AirIRmStopState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Timer Stop (1003)"
|
|
::= { airIRmPmCommon2 4}
|
|
|
|
airIRmPmSeqStop OBJECT-TYPE
|
|
SYNTAX AirIRmStopState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Seq. Stop (1004)"
|
|
::= { airIRmPmCommon2 5}
|
|
|
|
airIRmPmRemoteUPS OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote UPS (1006)"
|
|
::= { airIRmPmCommon2 7}
|
|
|
|
airIRmPmLocalUPS OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UPS (1007)"
|
|
::= { airIRmPmCommon2 8}
|
|
|
|
airIRmPmCommonAlarm OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Common alarm (1010)."
|
|
::= { airIRmPmCommon2 11 }
|
|
|
|
airIRmPmResetAllAlarms OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
doNothing (1),
|
|
reset (2) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all alarms control (1011)."
|
|
::= { airIRmPmCommon2 12 }
|
|
|
|
airIRmPmUnitOnOff OBJECT-TYPE
|
|
SYNTAX AirIRmControlState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit running state (1013)."
|
|
::= { airIRmPmCommon2 14 }
|
|
|
|
airIRmPmMaintenance OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notNecessary (1),
|
|
necessary (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maintenance necessary state (1014)."
|
|
::= { airIRmPmCommon2 15 }
|
|
|
|
airIRmPmUnitTemperatureScale OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
celsius (1),
|
|
fahrenheit (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current Unit Temperature Scale (1022)."
|
|
::= { airIRmPmCommon2 23 }
|
|
|
|
airIRmPmUnitWinterMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
summer (1),
|
|
winter (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Winter or summer configuration mode (1023)."
|
|
::= { airIRmPmCommon2 24 }
|
|
|
|
airIRmPmDayNightMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
day (1),
|
|
night (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day or night configuration mode (1024)."
|
|
::= { airIRmPmCommon2 25 }
|
|
|
|
|
|
-- airIRmPmCommon3
|
|
|
|
airIRmPmLastMaintenanceYear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Last maintenance year (1160)."
|
|
::= { airIRmPmCommon3 1 }
|
|
|
|
airIRmPmLastMaintenanceMonth OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Last maintenance month (1161)."
|
|
::= { airIRmPmCommon3 2 }
|
|
|
|
airIRmPmLastMaintenanceDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Last maintenance day (1162)."
|
|
::= { airIRmPmCommon3 3 }
|
|
|
|
airIRmPmUnitMaintenanceInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit maintenance interval in months (1163)."
|
|
::= { airIRmPmCommon3 4 }
|
|
|
|
airIRmPmRuntimeUnit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Runtime unit in hours (1164)."
|
|
::= { airIRmPmCommon3 5 }
|
|
|
|
airIRmPmStoptimeUnit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit stoptime in hours (1165)"
|
|
::= { airIRmPmCommon3 6 }
|
|
|
|
airIRmPmRuntimeCooling OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Cooling runtime in hours (1166)"
|
|
::= { airIRmPmCommon3 7 }
|
|
|
|
airIRmPmRuntimeHeating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Heating runtime in hours (1167)"
|
|
::= { airIRmPmCommon3 8 }
|
|
|
|
airIRmPmRuntimeHumidification OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidification runtime in hours (1168)"
|
|
::= { airIRmPmCommon3 9 }
|
|
|
|
airIRmPmRuntimeDehumidification OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dehumidification runtime in hours (1169)"
|
|
::= { airIRmPmCommon3 10 }
|
|
|
|
airIRmPmUnitTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon3 11 }
|
|
airIRmPmUnitTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit temperature in tenths of degrees Celsius (1170)."
|
|
::= { airIRmPmUnitTemperature 1 }
|
|
airIRmPmUnitTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit temperature in tenths of degrees Fahrenheit (1170)."
|
|
::= { airIRmPmUnitTemperature 2 }
|
|
|
|
airIRmPmUnitHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit humidity in tenths of %RH (1171)."
|
|
::= { airIRmPmCommon3 12 }
|
|
|
|
airIRmPmSetpointTemperatureDay OBJECT IDENTIFIER ::= { airIRmPmCommon3 14 }
|
|
airIRmPmSetpointTemperatureDayC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setpoint daytime temperature in tenths
|
|
of degrees Celsius (1173)."
|
|
::= { airIRmPmSetpointTemperatureDay 1 }
|
|
airIRmPmSetpointTemperatureDayF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setpoint daytime temperature in tenths
|
|
of degrees Fahrenheit (1173)."
|
|
::= { airIRmPmSetpointTemperatureDay 2 }
|
|
|
|
airIRmPmSetpointTemperatureNight OBJECT IDENTIFIER ::= { airIRmPmCommon3 15 }
|
|
airIRmPmSetpointTemperatureNightC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setpoint nighttime temperature in tenths
|
|
of degrees Celsius (1174)."
|
|
::= { airIRmPmSetpointTemperatureNight 1 }
|
|
airIRmPmSetpointTemperatureNightF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setpoint nighttime temperature in tenths
|
|
of degrees Fahrenheit (1174)."
|
|
::= { airIRmPmSetpointTemperatureNight 2 }
|
|
|
|
airIRmPmSetpointHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setpoint humidity in tenths of %RH (1176)."
|
|
::= { airIRmPmCommon3 17 }
|
|
|
|
airIRmPmUnitControlType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
room (1),
|
|
supply (2),
|
|
room-SupplyLimit (3),
|
|
supply-RoomLimit (4) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current unit control type (1183)."
|
|
::= { airIRmPmCommon3 24 }
|
|
|
|
airIRmPmWinterModeStartTemp OBJECT IDENTIFIER ::= { airIRmPmCommon3 29 }
|
|
airIRmPmWinterModeStartTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Winter mode start temperature in tenths of degrees Celsius (1188)."
|
|
::= { airIRmPmWinterModeStartTemp 1 }
|
|
airIRmPmWinterModeStartTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Winter mode start temperature in tenths of degrees Fahrenheit (1188)."
|
|
::= { airIRmPmWinterModeStartTemp 2 }
|
|
|
|
airIRmPmWinterModeHysteresis OBJECT IDENTIFIER ::= { airIRmPmCommon3 30 }
|
|
airIRmPmWinterModeHysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Winter mode hysteresis in tenths of Kelvins (1189)"
|
|
::= { airIRmPmWinterModeHysteresis 1 }
|
|
airIRmPmWinterModeHysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Winter mode hysteresis in tenths of degrees Fahrenheit (1189)"
|
|
::= { airIRmPmWinterModeHysteresis 2 }
|
|
|
|
airIRmPmWaterTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon3 32 }
|
|
airIRmPmWaterTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Water temperature in tenths of degrees Celsius (1191)."
|
|
::= { airIRmPmWaterTemperature 1 }
|
|
airIRmPmWaterTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Water temperature in tenths of degrees Fahrenheit (1191)."
|
|
::= { airIRmPmWaterTemperature 2 }
|
|
|
|
airIRmPmReturnAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon3 33 }
|
|
airIRmPmReturnAirTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Return air temperature in tenths of degrees Celsius (1192)."
|
|
::= { airIRmPmReturnAirTemperature 1 }
|
|
airIRmPmReturnAirTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Return air temperature in tenths of degrees Fahrenheit (1192)."
|
|
::= { airIRmPmReturnAirTemperature 2 }
|
|
|
|
airIRmPmSupplyAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon3 34 }
|
|
airIRmPmSupplyAirTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Supply air temperature in tenths of degrees Celsius (1193)."
|
|
::= { airIRmPmSupplyAirTemperature 1 }
|
|
airIRmPmSupplyAirTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Supply air temperature in tenths of degrees Fahrenheit (1193)."
|
|
::= { airIRmPmSupplyAirTemperature 2 }
|
|
|
|
airIRmPmReturnAirHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Return air humidity in tenths of %RH (1194)."
|
|
::= { airIRmPmCommon3 35 }
|
|
|
|
airIRmPmSupplyAirHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Supply air humidity in tenths of %RH (1195)."
|
|
::= { airIRmPmCommon3 36 }
|
|
|
|
airIRmPmOutsideAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon3 37 }
|
|
airIRmPmOutsideAirTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Outside air temperature in tenths of degrees Celsius (1196)"
|
|
::= { airIRmPmOutsideAirTemperature 1 }
|
|
airIRmPmOutsideAirTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Outside air temperature in tenths of degrees Fahrenheit (1196)"
|
|
::= { airIRmPmOutsideAirTemperature 2 }
|
|
|
|
airIRmPmOutsideAirHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Outside air humidity in tenths of percent relative humidity (1197)"
|
|
::= { airIRmPmCommon3 38 }
|
|
|
|
airIRmPmCoolingPriority OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ge (1),
|
|
cw (2),
|
|
dx (3) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Cooling priority (1198)."
|
|
::= { airIRmPmCommon3 39 }
|
|
|
|
airIRmPmWaterTemperature2 OBJECT IDENTIFIER ::= { airIRmPmCommon3 43 }
|
|
airIRmPmWaterTemperature2C OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Water temperature 2 in tenths of degrees Celsius (1202)."
|
|
::= { airIRmPmWaterTemperature2 1 }
|
|
airIRmPmWaterTemperature2F OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Water temperature 2 in tenths of degrees Fahrenheit (1202)."
|
|
::= { airIRmPmWaterTemperature2 2 }
|
|
|
|
airIRmPmRuntimeFreeCooling OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Freecooling runtime in hours (1203)"
|
|
::= { airIRmPmCommon3 44 }
|
|
|
|
airIRmPmRuntimeMixedModeFreeCooling OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mixed mode freecooling runtime in hours (1203)"
|
|
::= { airIRmPmCommon3 45 }
|
|
|
|
-- airIRmPmCommon4
|
|
|
|
airIRmPmNumberOfCompressors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of compressors (1761)"
|
|
::= { airIRmPmCommon4 4 }
|
|
|
|
airIRmPmNumberOfSuctionValves OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of suction valves (1762)"
|
|
::= { airIRmPmCommon4 5 }
|
|
|
|
airIRmPmNumberOfDryCoolers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of drycoolers (1763)"
|
|
::= { airIRmPmCommon4 6 }
|
|
|
|
airIRmPmNumberOfPumps OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of pumps (1764)"
|
|
::= { airIRmPmCommon4 7 }
|
|
|
|
airIRmPmNumberOfElectricHeaters OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of electric heaters (1765)"
|
|
::= { airIRmPmCommon4 8 }
|
|
|
|
airIRmPmNumberOfHumidifiers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of humidifiers (1766)"
|
|
::= { airIRmPmCommon4 9 }
|
|
|
|
airIRmPmNumberOfFans OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of fans (1767)"
|
|
::= { airIRmPmCommon4 10 }
|
|
|
|
airIRmPmNumberOfLouvers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of louvers (1768)"
|
|
::= { airIRmPmCommon4 11 }
|
|
|
|
airIRmPmNumberOfSensors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensors (1769)"
|
|
::= { airIRmPmCommon4 12 }
|
|
|
|
airIRmPmNumberOfExternalAlarmInputs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of external alarm inputs (1770)"
|
|
::= { airIRmPmCommon4 13 }
|
|
|
|
airIRmPmNumberOfGECWValves OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of GE/CW valves (1771)"
|
|
::= { airIRmPmCommon4 14 }
|
|
|
|
airIRmPmNumberOfHotGasReheat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of hot gas reheaters (1772)"
|
|
::= { airIRmPmCommon4 15 }
|
|
|
|
airIRmPmNumberOfPWWReheat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of PWW reheaters (1773)"
|
|
::= { airIRmPmCommon4 16 }
|
|
|
|
airIRmPmNumberOfDehumidifiers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of dehumidifiers (1774)"
|
|
::= { airIRmPmCommon4 17 }
|
|
|
|
-- airIRmPmCommon5
|
|
|
|
airIRmPmUnitEvaporationTemperature1 OBJECT IDENTIFIER ::= { airIRmPmCommon5 1 }
|
|
airIRmPmUnitEvaporationTemperature1C OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit evaporation temperature 1 in tenths
|
|
of degrees Celsius (2232)"
|
|
::= { airIRmPmUnitEvaporationTemperature1 1 }
|
|
airIRmPmUnitEvaporationTemperature1F OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit evaporation temperature 1 in tenths
|
|
of degrees Fahrenheit (2232)"
|
|
::= { airIRmPmUnitEvaporationTemperature1 2 }
|
|
|
|
airIRmPmUnitEvaporationPressure1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit evaporation pressure 1 in tenths
|
|
of Bars (2233)"
|
|
::= { airIRmPmCommon5 2 }
|
|
|
|
airIRmPmUnitCondensationTemperature1 OBJECT IDENTIFIER ::= { airIRmPmCommon5 3 }
|
|
airIRmPmUnitCondensationTemperature1C OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condensation temperature 1 in tenths
|
|
of degrees Celsius (2234)"
|
|
::= { airIRmPmUnitCondensationTemperature1 1 }
|
|
airIRmPmUnitCondensationTemperature1F OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condensation temperature 1 in tenths
|
|
of degrees Fahrenheit (2234)"
|
|
::= { airIRmPmUnitCondensationTemperature1 2 }
|
|
|
|
airIRmPmUnitCondensationPressure1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condensation pressure 1 in tenths
|
|
of Bars (2235)"
|
|
::= { airIRmPmCommon5 4 }
|
|
|
|
airIRmPmMaxLimitReturnAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 8 }
|
|
airIRmPmMaxLimitReturnAirTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum limit return air temperature in tenths
|
|
of degrees Celsius (2239)."
|
|
::= { airIRmPmMaxLimitReturnAirTemperature 1 }
|
|
airIRmPmMaxLimitReturnAirTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum limit return air temperature in tenths
|
|
of degrees Fahrenheit (2239)."
|
|
::= { airIRmPmMaxLimitReturnAirTemperature 2 }
|
|
|
|
airIRmPmMinLimitReturnAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 9 }
|
|
airIRmPmMinLimitReturnAirTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum limit return air temperature in tenths
|
|
of degrees Celsius (2240)."
|
|
::= { airIRmPmMinLimitReturnAirTemperature 1 }
|
|
airIRmPmMinLimitReturnAirTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum limit return air temperature in tenths
|
|
of degrees Fahrenheit (2240)."
|
|
::= { airIRmPmMinLimitReturnAirTemperature 2 }
|
|
|
|
airIRmPmMaxLimitSupplyAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 10 }
|
|
airIRmPmMaxLimitSupplyAirTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum limit supply air temperature in tenths
|
|
of degrees Celsius (2241)."
|
|
::= { airIRmPmMaxLimitSupplyAirTemperature 1 }
|
|
airIRmPmMaxLimitSupplyAirTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum limit supply air temperature in tenths
|
|
of degrees Fahrenheit (2241)."
|
|
::= { airIRmPmMaxLimitSupplyAirTemperature 2 }
|
|
|
|
airIRmPmMinLimitSupplyAirTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 11 }
|
|
airIRmPmMinLimitSupplyAirTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum limit supply air temperature in tenths
|
|
of degrees Celsius (2242)."
|
|
::= { airIRmPmMinLimitSupplyAirTemperature 1 }
|
|
airIRmPmMinLimitSupplyAirTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum limit supply air temperature in tenths
|
|
of degrees Fahrenheit (2242)."
|
|
::= { airIRmPmMinLimitSupplyAirTemperature 2 }
|
|
|
|
airIRmPmMaxLimitWaterTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 12 }
|
|
airIRmPmMaxLimitWaterTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum limit water temperature in tenths of degrees Celsius (2243)."
|
|
::= { airIRmPmMaxLimitWaterTemperature 1 }
|
|
airIRmPmMaxLimitWaterTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum limit water temperature in tenths
|
|
of degrees Fahrenheit (2243)."
|
|
::= { airIRmPmMaxLimitWaterTemperature 2 }
|
|
|
|
airIRmPmMinLimitWaterTemperature OBJECT IDENTIFIER ::= { airIRmPmCommon5 13 }
|
|
airIRmPmMinLimitWaterTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum limit water temperature in tenths
|
|
of degrees Celsius (2244)."
|
|
::= { airIRmPmMinLimitWaterTemperature 1 }
|
|
airIRmPmMinLimitWaterTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum limit water temperature in tenths
|
|
of degrees Fahrenheit (2244)."
|
|
::= { airIRmPmMinLimitWaterTemperature 2 }
|
|
|
|
airIRmPmMaxLimitReturnAirHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum limit return air humidity in tenths of %RH (2245)."
|
|
::= { airIRmPmCommon5 14 }
|
|
|
|
airIRmPmMinLimitReturnAirHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum limit return air humidity in tenths of %RH (2246)."
|
|
::= { airIRmPmCommon5 15 }
|
|
|
|
airIRmPmMaxLimitSupplyAirHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum limit supply air humidity in tenths of %RH (2247)."
|
|
::= { airIRmPmCommon5 16 }
|
|
|
|
airIRmPmMinLimitSupplyAirHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum limit supply air humidity in tenths of %RH (2248)."
|
|
::= { airIRmPmCommon5 17 }
|
|
|
|
airIRmPmLowPressureWinterDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Winter mode low pressure delay in seconds (2249)"
|
|
::= { airIRmPmCommon5 18 }
|
|
|
|
airIRmPmUnitCondensationPressure2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condensation pressure 2 in tenths of Bars (2250)"
|
|
::= { airIRmPmCommon5 19 }
|
|
|
|
airIRmPmUnitOverloadSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit overload switch setting in tenths of Kelvins (2251)"
|
|
::= { airIRmPmCommon5 20 }
|
|
|
|
airIRmPmUnitCondensationTemperature2 OBJECT IDENTIFIER ::= { airIRmPmCommon5 41 }
|
|
airIRmPmUnitCondensationTemperature2C OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condensation temperature 2 in tenths
|
|
of degrees Celsius (2272)"
|
|
::= { airIRmPmUnitCondensationTemperature2 1 }
|
|
airIRmPmUnitCondensationTemperature2F OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit condensation temperature 2 in tenths
|
|
of degrees Fahrenheit (2272)"
|
|
::= { airIRmPmUnitCondensationTemperature2 2 }
|
|
|
|
airIRmPmUnitEvaporationPressure2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit evaporation pressure 2 in tenths
|
|
of Bars (2273)"
|
|
::= { airIRmPmCommon5 42 }
|
|
|
|
airIRmPmUnitEvaporationTemperature2 OBJECT IDENTIFIER ::= { airIRmPmCommon5 43 }
|
|
airIRmPmUnitEvaporationTemperature2C OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit evaporation temperature 2 in tenths
|
|
of degrees Celsius (2274)"
|
|
::= { airIRmPmUnitEvaporationTemperature2 1 }
|
|
airIRmPmUnitEvaporationTemperature2F OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit evaporation temperature 2 in tenths
|
|
of degrees Fahrenheit (2274)"
|
|
::= { airIRmPmUnitEvaporationTemperature2 2 }
|
|
|
|
-- airIRmPmCompressor1
|
|
|
|
airIRmPmCmp1ManOperationActive OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
manual (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 manual operation active (4401)"
|
|
::= { airIRmPmCompressor1 2 }
|
|
|
|
airIRmPmCmp1ManOperationState OBJECT-TYPE
|
|
SYNTAX AirIRmControlState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 manual operation state (4402)"
|
|
::= { airIRmPmCompressor1 3 }
|
|
|
|
airIRmPmCmp1Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 running (4403)"
|
|
::= { airIRmPmCompressor1 4 }
|
|
|
|
airIRmPmCmp1StartTempSummer OBJECT IDENTIFIER ::= { airIRmPmCompressor1 17 }
|
|
airIRmPmCmp1StartTempSummerK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 summer mode start temperature
|
|
in tenths of Kelvins (4416)"
|
|
::= { airIRmPmCmp1StartTempSummer 1 }
|
|
airIRmPmCmp1StartTempSummerF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 summer mode start temperature
|
|
in tenths of degrees Fahrenheit (4416)"
|
|
::= { airIRmPmCmp1StartTempSummer 2 }
|
|
|
|
airIRmPmCmp1HysteresisSummer OBJECT IDENTIFIER ::= { airIRmPmCompressor1 18 }
|
|
airIRmPmCmp1HysteresisSummerK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 summer mode hysteresis setting
|
|
in tenths of Kelvins (4417)"
|
|
::= { airIRmPmCmp1HysteresisSummer 1 }
|
|
airIRmPmCmp1HysteresisSummerF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 summer mode hysteresis setting
|
|
in tenths of Fahrenheit (4417)"
|
|
::= { airIRmPmCmp1HysteresisSummer 2 }
|
|
|
|
airIRmPmCmp1StartTempWinter OBJECT IDENTIFIER ::= { airIRmPmCompressor1 19 }
|
|
airIRmPmCmp1StartTempWinterK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 winter mode start temperature
|
|
in tenths of Kelvins (4418)"
|
|
::= { airIRmPmCmp1StartTempWinter 1 }
|
|
airIRmPmCmp1StartTempWinterF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 winter mode start temperature
|
|
in tenths of degrees Fahrenheit (4418)"
|
|
::= { airIRmPmCmp1StartTempWinter 2 }
|
|
|
|
airIRmPmCmp1HysteresisWinter OBJECT IDENTIFIER ::= { airIRmPmCompressor1 20 }
|
|
airIRmPmCmp1HysteresisWinterK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 Winter mode hysteresis setting
|
|
in tenths of Kelvins (4419)"
|
|
::= { airIRmPmCmp1HysteresisWinter 1 }
|
|
airIRmPmCmp1HysteresisWinterF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 Winter mode hysteresis setting
|
|
in tenths of Fahrenheit (4419)"
|
|
::= { airIRmPmCmp1HysteresisWinter 2 }
|
|
|
|
airIRmPmCmp1Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 1 runtime in hours (4428)"
|
|
::= { airIRmPmCompressor1 29 }
|
|
|
|
-- airIRmPmCompressor2
|
|
|
|
airIRmPmCmp2ManOperationActive OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
manual (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 manual operation active (4501)"
|
|
::= { airIRmPmCompressor2 2 }
|
|
|
|
airIRmPmCmp2ManOperationState OBJECT-TYPE
|
|
SYNTAX AirIRmControlState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 manual operation state (4502)"
|
|
::= { airIRmPmCompressor2 3 }
|
|
|
|
airIRmPmCmp2Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 running (4503)"
|
|
::= { airIRmPmCompressor2 4 }
|
|
|
|
airIRmPmCmp2StartTempSummer OBJECT IDENTIFIER ::= { airIRmPmCompressor2 17 }
|
|
airIRmPmCmp2StartTempSummerK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 summer mode start temperature
|
|
in tenths of Kelvins (4516)"
|
|
::= { airIRmPmCmp2StartTempSummer 1 }
|
|
airIRmPmCmp2StartTempSummerF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 summer mode start temperature
|
|
in tenths of degrees Fahrenheit (4516)"
|
|
::= { airIRmPmCmp2StartTempSummer 2 }
|
|
|
|
airIRmPmCmp2HysteresisSummer OBJECT IDENTIFIER ::= { airIRmPmCompressor2 18 }
|
|
airIRmPmCmp2HysteresisSummerK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 summer mode hysteresis setting
|
|
in tenths of Kelvins (4517)"
|
|
::= { airIRmPmCmp2HysteresisSummer 1 }
|
|
airIRmPmCmp2HysteresisSummerF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 summer mode hysteresis setting
|
|
in tenths of Fahrenheit (4517)"
|
|
::= { airIRmPmCmp2HysteresisSummer 2 }
|
|
|
|
airIRmPmCmp2StartTempWinter OBJECT IDENTIFIER ::= { airIRmPmCompressor2 19 }
|
|
airIRmPmCmp2StartTempWinterK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 winter mode start temperature
|
|
in tenths of Kelvins (4518)"
|
|
::= { airIRmPmCmp2StartTempWinter 1 }
|
|
airIRmPmCmp2StartTempWinterF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 winter mode start temperature
|
|
in tenths of degrees Fahrenheit (4518)"
|
|
::= { airIRmPmCmp2StartTempWinter 2 }
|
|
|
|
airIRmPmCmp2HysteresisWinter OBJECT IDENTIFIER ::= { airIRmPmCompressor2 20 }
|
|
airIRmPmCmp2HysteresisWinterK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 Winter mode hysteresis setting
|
|
in tenths of Kelvins (4519)"
|
|
::= { airIRmPmCmp2HysteresisWinter 1 }
|
|
airIRmPmCmp2HysteresisWinterF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 Winter mode hysteresis setting
|
|
in tenths of Fahrenheit (4519)"
|
|
::= { airIRmPmCmp2HysteresisWinter 2 }
|
|
|
|
airIRmPmCmp2Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor 2 runtime in hours (4528)"
|
|
::= { airIRmPmCompressor2 29 }
|
|
|
|
-- airIRmPmSuctionValve1
|
|
-- Empty
|
|
|
|
-- airIRmPmSuctionValve2
|
|
-- Empty
|
|
|
|
-- airIRmPmEheating1
|
|
|
|
airIRmPmEheating1ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #1 manual operation enable (4801)"
|
|
::= { airIRmPmEheating1 2 }
|
|
|
|
airIRmPmEheating1Running OBJECT-TYPE
|
|
SYNTAX AirIRmControlState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #1 running state (4803)"
|
|
::= { airIRmPmEheating1 4 }
|
|
|
|
airIRmPmEheating1ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #1 running in manual operation mode (4804)"
|
|
::= { airIRmPmEheating1 5 }
|
|
|
|
airIRmPmEheating1Type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
direct (1),
|
|
pwm (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #1 type (4808)"
|
|
::= { airIRmPmEheating1 9 }
|
|
|
|
airIRmPmEheating1StartTemperature OBJECT IDENTIFIER ::= { airIRmPmEheating1 10 }
|
|
airIRmPmEheating1StartTemperatureK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #1 start temperature in tenths of Kelvins (4809)"
|
|
::= { airIRmPmEheating1StartTemperature 1 }
|
|
airIRmPmEheating1StartTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #1 start temperature in tenths of degrees Fahrenheit (4809)"
|
|
::= { airIRmPmEheating1StartTemperature 2 }
|
|
|
|
airIRmPmEheating1Hysteresis OBJECT IDENTIFIER ::= { airIRmPmEheating1 11 }
|
|
airIRmPmEheating1HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #1 hysteresis in tenths of Kelvins (4810)"
|
|
::= { airIRmPmEheating1Hysteresis 1 }
|
|
airIRmPmEheating1HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #1 hysteresis in tenths of degrees Fahrenheit (4810)"
|
|
::= { airIRmPmEheating1Hysteresis 2 }
|
|
|
|
airIRmPmEheating1Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #1 runtime in hours (4816)"
|
|
::= { airIRmPmEheating1 17 }
|
|
|
|
-- airIRmPmEheating2
|
|
|
|
airIRmPmEheating2ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #2 manual operation enable (4901)"
|
|
::= { airIRmPmEheating2 2 }
|
|
|
|
airIRmPmEheating2Running OBJECT-TYPE
|
|
SYNTAX AirIRmControlState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #2 running state (4903)"
|
|
::= { airIRmPmEheating2 4 }
|
|
|
|
airIRmPmEheating2ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #2 running in manual operation mode (4904)"
|
|
::= { airIRmPmEheating2 5 }
|
|
|
|
airIRmPmEheating2Type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
direct (1),
|
|
pwm (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #2 type (4908)"
|
|
::= { airIRmPmEheating2 9 }
|
|
|
|
airIRmPmEheating2StartTemperature OBJECT IDENTIFIER ::= { airIRmPmEheating2 10 }
|
|
airIRmPmEheating2StartTemperatureK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #2 start temperature in tenths of Kelvins (4909)"
|
|
::= { airIRmPmEheating2StartTemperature 1 }
|
|
airIRmPmEheating2StartTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #2 start temperature in tenths of degrees Fahrenheit (4909)"
|
|
::= { airIRmPmEheating2StartTemperature 2 }
|
|
|
|
airIRmPmEheating2Hysteresis OBJECT IDENTIFIER ::= { airIRmPmEheating2 11 }
|
|
airIRmPmEheating2HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #2 hysteresis in tenths of Kelvins (4910)"
|
|
::= { airIRmPmEheating2Hysteresis 1 }
|
|
airIRmPmEheating2HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #2 hysteresis in tenths of degrees Fahrenheit (4910)"
|
|
::= { airIRmPmEheating2Hysteresis 2 }
|
|
|
|
airIRmPmEheating2Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #2 runtime in hours (4916)"
|
|
::= { airIRmPmEheating2 17 }
|
|
|
|
-- airIRmPmEheating3
|
|
|
|
airIRmPmEheating3ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #3 manual operation enable (5001)"
|
|
::= { airIRmPmEheating3 2 }
|
|
|
|
airIRmPmEheating3Running OBJECT-TYPE
|
|
SYNTAX AirIRmControlState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #3 running state (5003)"
|
|
::= { airIRmPmEheating3 4 }
|
|
|
|
airIRmPmEheating3ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #3 running in manual operation mode (5004)"
|
|
::= { airIRmPmEheating3 5 }
|
|
|
|
airIRmPmEheating3Type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
direct (1),
|
|
pwm (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #3 type (5008)"
|
|
::= { airIRmPmEheating3 9 }
|
|
|
|
airIRmPmEheating3StartTemperature OBJECT IDENTIFIER ::= { airIRmPmEheating3 10 }
|
|
airIRmPmEheating3StartTemperatureK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #3 start temperature in tenths of Kelvins (5009)"
|
|
::= { airIRmPmEheating3StartTemperature 1 }
|
|
airIRmPmEheating3StartTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #3 start temperature in tenths of degrees Fahrenheit (5009)"
|
|
::= { airIRmPmEheating3StartTemperature 2 }
|
|
|
|
airIRmPmEheating3Hysteresis OBJECT IDENTIFIER ::= { airIRmPmEheating3 11 }
|
|
airIRmPmEheating3HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #3 hysteresis in tenths of Kelvins (5010)"
|
|
::= { airIRmPmEheating3Hysteresis 1 }
|
|
airIRmPmEheating3HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #3 hysteresis in tenths of degrees Fahrenheit (5010)"
|
|
::= { airIRmPmEheating3Hysteresis 2 }
|
|
|
|
airIRmPmEheating3Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #3 runtime in hours (5016)"
|
|
::= { airIRmPmEheating3 17 }
|
|
|
|
-- airIRmPmEheating4
|
|
|
|
airIRmPmEheating4ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #4 manual operation enable (5101)"
|
|
::= { airIRmPmEheating4 2 }
|
|
|
|
airIRmPmEheating4Running OBJECT-TYPE
|
|
SYNTAX AirIRmControlState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #4 running state (5103)"
|
|
::= { airIRmPmEheating4 4 }
|
|
|
|
airIRmPmEheating4ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #4 running in manual operation mode (5104)"
|
|
::= { airIRmPmEheating4 5 }
|
|
|
|
airIRmPmEheating4Type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
direct (1),
|
|
pwm (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #4 type (5108)"
|
|
::= { airIRmPmEheating4 9 }
|
|
|
|
airIRmPmEheating4StartTemperature OBJECT IDENTIFIER ::= { airIRmPmEheating4 10 }
|
|
airIRmPmEheating4StartTemperatureK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #4 start temperature in tenths of Kelvins (5109)"
|
|
::= { airIRmPmEheating4StartTemperature 1 }
|
|
airIRmPmEheating4StartTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #4 start temperature in tenths of degrees Fahrenheit (5109)"
|
|
::= { airIRmPmEheating4StartTemperature 2 }
|
|
|
|
airIRmPmEheating4Hysteresis OBJECT IDENTIFIER ::= { airIRmPmEheating4 11 }
|
|
airIRmPmEheating4HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #4 hysteresis in tenths of Kelvins (5110)"
|
|
::= { airIRmPmEheating4Hysteresis 1 }
|
|
airIRmPmEheating4HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #4 hysteresis in tenths of degrees Fahrenheit (5110)"
|
|
::= { airIRmPmEheating4Hysteresis 2 }
|
|
|
|
airIRmPmEheating4Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Electric heater #4 runtime in hours (5116)"
|
|
::= { airIRmPmEheating4 17 }
|
|
|
|
-- airIRmPmGECWvalve
|
|
|
|
airIRmPmGECWvalveManOpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"GE/CW valve manual operation enable (5201)"
|
|
::= { airIRmPmGECWvalve 2 }
|
|
|
|
airIRmPmGECWvalveStartTemperature OBJECT IDENTIFIER ::= { airIRmPmGECWvalve 9 }
|
|
airIRmPmGECWvalveStartTemperatureK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"GE/CW valve start temperature in tenths of Kelvins (5208)"
|
|
::= { airIRmPmGECWvalveStartTemperature 1 }
|
|
airIRmPmGECWvalveStartTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"GE/CW valve start temperature in tenths of degrees Fahrenheit (5208)"
|
|
::= { airIRmPmGECWvalveStartTemperature 2 }
|
|
|
|
airIRmPmGECWvalveLinearRange OBJECT IDENTIFIER ::= { airIRmPmGECWvalve 10 }
|
|
airIRmPmGECWvalveLinearRangeK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"GE/CW valve linear range in tenths of Kelvins (5209)"
|
|
::= { airIRmPmGECWvalveLinearRange 1 }
|
|
airIRmPmGECWvalveLinearRangeF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"GE/CW valve linear range in tenths of degrees Fahrenheit (5209)"
|
|
::= { airIRmPmGECWvalveLinearRange 2 }
|
|
|
|
airIRmPmGECWvalveGEOffTemp OBJECT IDENTIFIER ::= { airIRmPmGECWvalve 12 }
|
|
airIRmPmGECWvalveGEOffTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"GE/CW valve GE off temperature in tenths of degrees Celsius (5211)"
|
|
::= { airIRmPmGECWvalveGEOffTemp 1 }
|
|
airIRmPmGECWvalveGEOffTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"GE/CW valve GE off temperature in tenths of degrees Fahrenheit (5211)"
|
|
::= { airIRmPmGECWvalveGEOffTemp 2 }
|
|
|
|
airIRmPmGECWvalveOpeningGrade OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"GE/CW valve opening grade in percent (5214)"
|
|
::= { airIRmPmGECWvalve 15 }
|
|
|
|
airIRmPmGECWvalveManOpOpeningGrade OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"GE/CW valve manual operation opening grade in percent (5215)"
|
|
::= { airIRmPmGECWvalve 16 }
|
|
|
|
-- airIRmPmGvalve
|
|
|
|
airIRmPmGvalveManOperationEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"G-valve manual operation enable (5301)"
|
|
::= { airIRmPmGvalve 2 }
|
|
|
|
airIRmPmGvalvePreOpeningTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"G-valve pre-opening time in seconds (5310)"
|
|
::= { airIRmPmGvalve 11 }
|
|
|
|
airIRmPmGvalvePreOpeningGrade OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"G-valve pre-opening grade in percent (5311)"
|
|
::= { airIRmPmGvalve 12 }
|
|
|
|
airIRmPmGvalveOpeningGrade OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"G-valve opening grade in percent (5312)"
|
|
::= { airIRmPmGvalve 13 }
|
|
|
|
airIRmPmGvalveManOpOpeningGrade OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"G-valve manual operation opening grade in percent (5313)"
|
|
::= { airIRmPmGvalve 14 }
|
|
|
|
-- airIRmPmDrycooler1
|
|
|
|
airIRmPmDrycooler1ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 1 manual operation enable setting (5401)"
|
|
::= { airIRmPmDrycooler1 2 }
|
|
|
|
airIRmPmDrycooler1Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 1 running (5402)"
|
|
::= { airIRmPmDrycooler1 3 }
|
|
|
|
airIRmPmDrycooler1ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 1 manual operation running (5404)"
|
|
::= { airIRmPmDrycooler1 5 }
|
|
|
|
airIRmPmDrycooler1WinterStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler1 9 }
|
|
airIRmPmDrycooler1WinterStartTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 1 winter mode start temperature
|
|
in tenths of degrees Celsius (5408)"
|
|
::= { airIRmPmDrycooler1WinterStartTemp 1 }
|
|
airIRmPmDrycooler1WinterStartTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 1 winter mode start temperature
|
|
in tenths of degrees Fahrenheit (5408)"
|
|
::= { airIRmPmDrycooler1WinterStartTemp 2 }
|
|
|
|
airIRmPmDrycooler1SummerStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler1 10 }
|
|
airIRmPmDrycooler1SummerStartTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 1 summer mode start temperature
|
|
in tenths of degrees Celsius (5409)"
|
|
::= { airIRmPmDrycooler1SummerStartTemp 1 }
|
|
airIRmPmDrycooler1SummerStartTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 1 summer mode start temperature
|
|
in tenths of degrees Fahrenheit (5409)"
|
|
::= { airIRmPmDrycooler1SummerStartTemp 2 }
|
|
|
|
airIRmPmDrycooler1Hysteresis OBJECT IDENTIFIER ::= { airIRmPmDrycooler1 11 }
|
|
airIRmPmDrycooler1HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 1 hysteresis in tenths of Kelvins (5410)"
|
|
::= { airIRmPmDrycooler1Hysteresis 1 }
|
|
airIRmPmDrycooler1HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 1 hysteresis in tenths of degrees Fahrenheit (5410)"
|
|
::= { airIRmPmDrycooler1Hysteresis 2 }
|
|
|
|
airIRmPmDrycooler1Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 1 runtime in hours (5415)"
|
|
::= { airIRmPmDrycooler1 16 }
|
|
|
|
-- airIRmPmDrycooler2
|
|
|
|
airIRmPmDrycooler2ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 2 manual operation enable setting (5501)"
|
|
::= { airIRmPmDrycooler2 2 }
|
|
|
|
airIRmPmDrycooler2Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 2 running (5502)"
|
|
::= { airIRmPmDrycooler2 3 }
|
|
|
|
airIRmPmDrycooler2ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 2 manual operation running (5504)"
|
|
::= { airIRmPmDrycooler2 5 }
|
|
|
|
airIRmPmDrycooler2WinterStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler2 9 }
|
|
airIRmPmDrycooler2WinterStartTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 2 winter mode start temperature
|
|
in tenths of degrees Celsius (5508)"
|
|
::= { airIRmPmDrycooler2WinterStartTemp 1 }
|
|
airIRmPmDrycooler2WinterStartTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 2 winter mode start temperature
|
|
in tenths of degrees Fahrenheit (5508)"
|
|
::= { airIRmPmDrycooler2WinterStartTemp 2 }
|
|
|
|
airIRmPmDrycooler2SummerStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler2 10 }
|
|
airIRmPmDrycooler2SummerStartTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 2 summer mode start temperature
|
|
in tenths of degrees Celsius (5509)"
|
|
::= { airIRmPmDrycooler2SummerStartTemp 1 }
|
|
airIRmPmDrycooler2SummerStartTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 2 summer mode start temperature
|
|
in tenths of degrees Fahrenheit (5509)"
|
|
::= { airIRmPmDrycooler2SummerStartTemp 2 }
|
|
|
|
airIRmPmDrycooler2Hysteresis OBJECT IDENTIFIER ::= { airIRmPmDrycooler2 11 }
|
|
airIRmPmDrycooler2HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 2 hysteresis in tenths of Kelvins (5510)"
|
|
::= { airIRmPmDrycooler2Hysteresis 1 }
|
|
airIRmPmDrycooler2HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 2 hysteresis in tenths of degrees Fahrenheit (5510)"
|
|
::= { airIRmPmDrycooler2Hysteresis 2 }
|
|
|
|
airIRmPmDrycooler2Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 2 runtime in hours (5515)"
|
|
::= { airIRmPmDrycooler2 16 }
|
|
|
|
-- airIRmPmDrycooler3
|
|
|
|
airIRmPmDrycooler3ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 3 manual operation enable setting (5601)"
|
|
::= { airIRmPmDrycooler3 2 }
|
|
|
|
airIRmPmDrycooler3Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 3 running (5602)"
|
|
::= { airIRmPmDrycooler3 3 }
|
|
|
|
airIRmPmDrycooler3ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 3 manual operation running (5604)"
|
|
::= { airIRmPmDrycooler3 5 }
|
|
|
|
airIRmPmDrycooler3WinterStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler3 9 }
|
|
airIRmPmDrycooler3WinterStartTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 3 winter mode start temperature
|
|
in tenths of degrees Celsius (5608)"
|
|
::= { airIRmPmDrycooler3WinterStartTemp 1 }
|
|
airIRmPmDrycooler3WinterStartTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 3 winter mode start temperature
|
|
in tenths of degrees Fahrenheit (5608)"
|
|
::= { airIRmPmDrycooler3WinterStartTemp 2 }
|
|
|
|
airIRmPmDrycooler3SummerStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler3 10 }
|
|
airIRmPmDrycooler3SummerStartTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 3 summer mode start temperature
|
|
in tenths of degrees Celsius (5609)"
|
|
::= { airIRmPmDrycooler3SummerStartTemp 1 }
|
|
airIRmPmDrycooler3SummerStartTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 3 summer mode start temperature
|
|
in tenths of degrees Fahrenheit (5609)"
|
|
::= { airIRmPmDrycooler3SummerStartTemp 2 }
|
|
|
|
airIRmPmDrycooler3Hysteresis OBJECT IDENTIFIER ::= { airIRmPmDrycooler3 11 }
|
|
airIRmPmDrycooler3HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 3 hysteresis in tenths of Kelvins (5610)"
|
|
::= { airIRmPmDrycooler3Hysteresis 1 }
|
|
airIRmPmDrycooler3HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 3 hysteresis in tenths of degrees Fahrenheit (5610)"
|
|
::= { airIRmPmDrycooler3Hysteresis 2 }
|
|
|
|
airIRmPmDrycooler3Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 3 runtime in hours (5615)"
|
|
::= { airIRmPmDrycooler3 16 }
|
|
|
|
-- airIRmPmDrycooler4
|
|
|
|
airIRmPmDrycooler4ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 4 manual operation enable setting (5701)"
|
|
::= { airIRmPmDrycooler4 2 }
|
|
|
|
airIRmPmDrycooler4Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 4 running (5702)"
|
|
::= { airIRmPmDrycooler4 3 }
|
|
|
|
airIRmPmDrycooler4ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 4 manual operation running (5704)"
|
|
::= { airIRmPmDrycooler4 5 }
|
|
|
|
airIRmPmDrycooler4WinterStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler4 9 }
|
|
airIRmPmDrycooler4WinterStartTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 4 winter mode start temperature
|
|
in tenths of degrees Celsius (5708)"
|
|
::= { airIRmPmDrycooler4WinterStartTemp 1 }
|
|
airIRmPmDrycooler4WinterStartTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 4 winter mode start temperature
|
|
in tenths of degrees Fahrenheit (5708)"
|
|
::= { airIRmPmDrycooler4WinterStartTemp 2 }
|
|
|
|
airIRmPmDrycooler4SummerStartTemp OBJECT IDENTIFIER ::= { airIRmPmDrycooler4 10 }
|
|
airIRmPmDrycooler4SummerStartTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 4 summer mode start temperature
|
|
in tenths of degrees Celsius (5709)"
|
|
::= { airIRmPmDrycooler4SummerStartTemp 1 }
|
|
airIRmPmDrycooler4SummerStartTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 4 summer mode start temperature
|
|
in tenths of degrees Fahrenheit (5709)"
|
|
::= { airIRmPmDrycooler4SummerStartTemp 2 }
|
|
|
|
airIRmPmDrycooler4Hysteresis OBJECT IDENTIFIER ::= { airIRmPmDrycooler4 11 }
|
|
airIRmPmDrycooler4HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 4 hysteresis in tenths of Kelvins (5710)"
|
|
::= { airIRmPmDrycooler4Hysteresis 1 }
|
|
airIRmPmDrycooler4HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 4 hysteresis in tenths of degrees Fahrenheit (5710)"
|
|
::= { airIRmPmDrycooler4Hysteresis 2 }
|
|
|
|
airIRmPmDrycooler4Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler 4 runtime in hours (5715)"
|
|
::= { airIRmPmDrycooler4 16 }
|
|
|
|
-- airIRmPmPump1
|
|
|
|
airIRmPmPump1ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 manual operation enable state (5801)"
|
|
::= { airIRmPmPump1 2 }
|
|
|
|
airIRmPmPump1Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 running (5802)"
|
|
::= { airIRmPmPump1 3 }
|
|
|
|
airIRmPmPump1ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 manual operation running (5805)"
|
|
::= { airIRmPmPump1 6 }
|
|
|
|
airIRmPmPump1StartTemperature OBJECT IDENTIFIER ::= { airIRmPmPump1 10 }
|
|
airIRmPmPump1StartTemperatureK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 starting temperature in tenths of Kelvins (5809)"
|
|
::= { airIRmPmPump1StartTemperature 1 }
|
|
airIRmPmPump1StartTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 starting temperature in tenths of degrees Fahrenheit (5809)"
|
|
::= { airIRmPmPump1StartTemperature 2 }
|
|
|
|
airIRmPmPump1Hysteresis OBJECT IDENTIFIER ::= { airIRmPmPump1 11 }
|
|
airIRmPmPump1HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 hysteresis in tenths of Kelvins (5810)"
|
|
::= { airIRmPmPump1Hysteresis 1 }
|
|
airIRmPmPump1HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 hysteresis in tenths of degrees Fahrenheit (5810)"
|
|
::= { airIRmPmPump1Hysteresis 2 }
|
|
|
|
airIRmPmPump1LinearRange OBJECT IDENTIFIER ::= { airIRmPmPump1 12 }
|
|
airIRmPmPump1LinearRangeK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 linear range in tenths of Kelvins (5811)"
|
|
::= { airIRmPmPump1LinearRange 1 }
|
|
airIRmPmPump1LinearRangeF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 linear range in tenths of degrees Fahrenheit (5811)"
|
|
::= { airIRmPmPump1LinearRange 2 }
|
|
|
|
airIRmPmPump1PressureSetpoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 pressure setpoint in tenths of Bars (5812)"
|
|
::= { airIRmPmPump1 13 }
|
|
|
|
airIRmPmPump1Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 runtime in hours (5820)"
|
|
::= { airIRmPmPump1 21 }
|
|
|
|
airIRmPmPump1Speed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 speed in percent (5821)"
|
|
::= { airIRmPmPump1 22 }
|
|
|
|
airIRmPmPump1ControlCycle OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 control cycle length in seconds (5827)"
|
|
::= { airIRmPmPump1 28 }
|
|
|
|
airIRmPmPump1MaxAdjust OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 maximum adjustment in percent (5828)"
|
|
::= { airIRmPmPump1 29 }
|
|
|
|
airIRmPmPump1ControlFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 1 control factor setting (5829)"
|
|
::= { airIRmPmPump1 30 }
|
|
|
|
-- airIRmPmPump2
|
|
|
|
airIRmPmPump2ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 manual operation enable state (5901)"
|
|
::= { airIRmPmPump2 2 }
|
|
|
|
airIRmPmPump2Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 running (5902)"
|
|
::= { airIRmPmPump2 3 }
|
|
|
|
airIRmPmPump2ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 manual operation running (5905)"
|
|
::= { airIRmPmPump2 6 }
|
|
|
|
airIRmPmPump2StartTemperature OBJECT IDENTIFIER ::= { airIRmPmPump2 10 }
|
|
airIRmPmPump2StartTemperatureK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 starting temperature in tenths of Kelvins (5909)"
|
|
::= { airIRmPmPump2StartTemperature 1 }
|
|
airIRmPmPump2StartTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 starting temperature in tenths of degrees Fahrenheit (5909)"
|
|
::= { airIRmPmPump2StartTemperature 2 }
|
|
|
|
airIRmPmPump2Hysteresis OBJECT IDENTIFIER ::= { airIRmPmPump2 11 }
|
|
airIRmPmPump2HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 hysteresis in tenths of Kelvins (5910)"
|
|
::= { airIRmPmPump2Hysteresis 1 }
|
|
airIRmPmPump2HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 hysteresis in tenths of degrees Fahrenheit (5910)"
|
|
::= { airIRmPmPump2Hysteresis 2 }
|
|
|
|
airIRmPmPump2LinearRange OBJECT IDENTIFIER ::= { airIRmPmPump2 12 }
|
|
airIRmPmPump2LinearRangeK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 linear range in tenths of Kelvins (5911)"
|
|
::= { airIRmPmPump2LinearRange 1 }
|
|
airIRmPmPump2LinearRangeF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 linear range in tenths of degrees Fahrenheit (5911)"
|
|
::= { airIRmPmPump2LinearRange 2 }
|
|
|
|
airIRmPmPump2PressureSetpoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 pressure setpoint in tenths of Bars (5912)"
|
|
::= { airIRmPmPump2 13 }
|
|
|
|
airIRmPmPump2Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 runtime in hours (5920)"
|
|
::= { airIRmPmPump2 21 }
|
|
|
|
airIRmPmPump2Speed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 speed in percent (5921)"
|
|
::= { airIRmPmPump2 22 }
|
|
|
|
airIRmPmPump2ControlCycle OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 control cycle length in seconds (5927)"
|
|
::= { airIRmPmPump2 28 }
|
|
|
|
airIRmPmPump2MaxAdjust OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 maximum adjustment in percent (5928)"
|
|
::= { airIRmPmPump2 29 }
|
|
|
|
airIRmPmPump2ControlFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 2 control factor setting (5929)"
|
|
::= { airIRmPmPump2 30 }
|
|
|
|
-- airIRmPmPump3
|
|
|
|
airIRmPmPump3ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 manual operation enable state (6001)"
|
|
::= { airIRmPmPump3 2 }
|
|
|
|
airIRmPmPump3Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 running (6002)"
|
|
::= { airIRmPmPump3 3 }
|
|
|
|
airIRmPmPump3ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 manual operation running (6005)"
|
|
::= { airIRmPmPump3 6 }
|
|
|
|
airIRmPmPump3StartTemperature OBJECT IDENTIFIER ::= { airIRmPmPump3 10 }
|
|
airIRmPmPump3StartTemperatureK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 starting temperature in tenths of Kelvins (6009)"
|
|
::= { airIRmPmPump3StartTemperature 1 }
|
|
airIRmPmPump3StartTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 starting temperature in tenths of degrees Fahrenheit (6009)"
|
|
::= { airIRmPmPump3StartTemperature 2 }
|
|
|
|
airIRmPmPump3Hysteresis OBJECT IDENTIFIER ::= { airIRmPmPump3 11 }
|
|
airIRmPmPump3HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 hysteresis in tenths of Kelvins (6010)"
|
|
::= { airIRmPmPump3Hysteresis 1 }
|
|
airIRmPmPump3HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 hysteresis in tenths of degrees Fahrenheit (6010)"
|
|
::= { airIRmPmPump3Hysteresis 2 }
|
|
|
|
airIRmPmPump3LinearRange OBJECT IDENTIFIER ::= { airIRmPmPump3 12 }
|
|
airIRmPmPump3LinearRangeK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 linear range in tenths of Kelvins (6011)"
|
|
::= { airIRmPmPump3LinearRange 1 }
|
|
airIRmPmPump3LinearRangeF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 linear range in tenths of degrees Fahrenheit (6011)"
|
|
::= { airIRmPmPump3LinearRange 2 }
|
|
|
|
airIRmPmPump3PressureSetpoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 pressure setpoint in tenths of Bars (6012)"
|
|
::= { airIRmPmPump3 13 }
|
|
|
|
airIRmPmPump3Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 runtime in hours (6020)"
|
|
::= { airIRmPmPump3 21 }
|
|
|
|
airIRmPmPump3Speed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 speed in percent (6021)"
|
|
::= { airIRmPmPump3 22 }
|
|
|
|
airIRmPmPump3ControlCycle OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 control cycle length in seconds (6027)"
|
|
::= { airIRmPmPump3 28 }
|
|
|
|
airIRmPmPump3MaxAdjust OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 maximum adjustment in percent (6028)"
|
|
::= { airIRmPmPump3 29 }
|
|
|
|
airIRmPmPump3ControlFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 3 control factor setting (6029)"
|
|
::= { airIRmPmPump3 30 }
|
|
|
|
-- airIRmPmPump4
|
|
|
|
airIRmPmPump4ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 manual operation enable state (6101)"
|
|
::= { airIRmPmPump4 2 }
|
|
|
|
airIRmPmPump4Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 running (6102)"
|
|
::= { airIRmPmPump4 3 }
|
|
|
|
airIRmPmPump4ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 manual operation running (6105)"
|
|
::= { airIRmPmPump4 6 }
|
|
|
|
airIRmPmPump4StartTemperature OBJECT IDENTIFIER ::= { airIRmPmPump4 10 }
|
|
airIRmPmPump4StartTemperatureK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 starting temperature in tenths of Kelvins (6109)"
|
|
::= { airIRmPmPump4StartTemperature 1 }
|
|
airIRmPmPump4StartTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 starting temperature in tenths of degrees Fahrenheit (6109)"
|
|
::= { airIRmPmPump4StartTemperature 2 }
|
|
|
|
airIRmPmPump4Hysteresis OBJECT IDENTIFIER ::= { airIRmPmPump4 11 }
|
|
airIRmPmPump4HysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 hysteresis in tenths of Kelvins (6110)"
|
|
::= { airIRmPmPump4Hysteresis 1 }
|
|
airIRmPmPump4HysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 hysteresis in tenths of degrees Fahrenheit (6110)"
|
|
::= { airIRmPmPump4Hysteresis 2 }
|
|
|
|
airIRmPmPump4LinearRange OBJECT IDENTIFIER ::= { airIRmPmPump4 12 }
|
|
airIRmPmPump4LinearRangeK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 linear range in tenths of Kelvins (6111)"
|
|
::= { airIRmPmPump4LinearRange 1 }
|
|
airIRmPmPump4LinearRangeF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 linear range in tenths of degrees Fahrenheit (6111)"
|
|
::= { airIRmPmPump4LinearRange 2 }
|
|
|
|
airIRmPmPump4PressureSetpoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 pressure setpoint in tenths of Bars (6112)"
|
|
::= { airIRmPmPump4 13 }
|
|
|
|
airIRmPmPump4Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 runtime in hours (6120)"
|
|
::= { airIRmPmPump4 21 }
|
|
|
|
airIRmPmPump4Speed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 speed in percent (6121)"
|
|
::= { airIRmPmPump4 22 }
|
|
|
|
airIRmPmPump4ControlCycle OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 control cycle length in seconds (6127)"
|
|
::= { airIRmPmPump4 28 }
|
|
|
|
airIRmPmPump4MaxAdjust OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 maximum adjustment in percent (6128)"
|
|
::= { airIRmPmPump4 29 }
|
|
|
|
airIRmPmPump4ControlFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump 4 control factor setting (6129)"
|
|
::= { airIRmPmPump4 30 }
|
|
|
|
-- airIRmPmHotgasHeating
|
|
|
|
airIRmPmHotgasHeatRunning OBJECT-TYPE
|
|
SYNTAX AirIRmControlState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hotgas heat running state. (6202)"
|
|
::= { airIRmPmHotgasHeating 3 }
|
|
|
|
-- airIRmPmPWWHeating
|
|
|
|
airIRmPmPWWHeatingManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating manual operation enable (6301)"
|
|
::= { airIRmPmPWWHeating 2 }
|
|
|
|
airIRmPmPWWHeatingRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating running (6302)"
|
|
::= { airIRmPmPWWHeating 3 }
|
|
|
|
airIRmPmPWWHeatingManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating manual operation running (6303)"
|
|
::= { airIRmPmPWWHeating 4 }
|
|
|
|
airIRmPmPWWHeatingType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
direct (1),
|
|
undefined (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating type (6308)"
|
|
::= { airIRmPmPWWHeating 9 }
|
|
|
|
airIRmPmPWWHeatingStartTemp OBJECT IDENTIFIER ::= { airIRmPmPWWHeating 10 }
|
|
airIRmPmPWWHeatingStartTempK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating starting temperature in Kelvins (6309)"
|
|
::= { airIRmPmPWWHeatingStartTemp 1 }
|
|
airIRmPmPWWHeatingStartTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating starting temperature in degrees Fahrenheit (6309)"
|
|
::= { airIRmPmPWWHeatingStartTemp 2 }
|
|
|
|
airIRmPmPWWHeatingHysteresis OBJECT IDENTIFIER ::= { airIRmPmPWWHeating 12 }
|
|
airIRmPmPWWHeatingHysteresisK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating hysteresis in Kelvins (6311)"
|
|
::= { airIRmPmPWWHeatingHysteresis 1 }
|
|
airIRmPmPWWHeatingHysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating hysteresis in degrees Fahrenheit (6311)"
|
|
::= { airIRmPmPWWHeatingHysteresis 2 }
|
|
|
|
airIRmPmPWWHeatingLinearRange OBJECT IDENTIFIER ::= { airIRmPmPWWHeating 13 }
|
|
airIRmPmPWWHeatingLinearRangeK OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating linear range in Kelvins (6312)"
|
|
::= { airIRmPmPWWHeatingLinearRange 1 }
|
|
airIRmPmPWWHeatingLinearRangeF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating linear range in degrees Fahrenheit (6312)"
|
|
::= { airIRmPmPWWHeatingLinearRange 2 }
|
|
|
|
airIRmPmPWWHeatingCurrentValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating current value in percent (6315)"
|
|
::= { airIRmPmPWWHeating 16 }
|
|
|
|
airIRmPmPWWHeatingManOpValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PWW-heating manual operation value in percent (6316)"
|
|
::= { airIRmPmPWWHeating 17 }
|
|
|
|
-- airIRmPmHumidifier1
|
|
|
|
airIRmPmHumidifier1ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 manual operation enable (6401)"
|
|
::= { airIRmPmHumidifier1 2 }
|
|
|
|
airIRmPmHumidifier1Running OBJECT-TYPE
|
|
SYNTAX AirIRmControlState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 running state (6402)"
|
|
::= { airIRmPmHumidifier1 3 }
|
|
|
|
airIRmPmHumidifier1ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 manual operation running state (6404)"
|
|
::= { airIRmPmHumidifier1 5 }
|
|
|
|
airIRmPmHumidifier1Type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
direct (1),
|
|
proportional (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 type (6416)"
|
|
::= { airIRmPmHumidifier1 17 }
|
|
|
|
airIRmPmHumidifier1StartHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 start humidity in tenths
|
|
of percent relative humidity (6417)"
|
|
::= { airIRmPmHumidifier1 18 }
|
|
|
|
airIRmPmHumidifier1Hysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 hysteresis in tenths
|
|
of percent relative humidity (6419)"
|
|
::= { airIRmPmHumidifier1 20 }
|
|
|
|
airIRmPmHumidifier1LinearRange OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 linear range in tenths
|
|
of percent relative humidity per Kelvin (6420)"
|
|
::= { airIRmPmHumidifier1 21 }
|
|
|
|
airIRmPmHumidifier1Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 runtime in hours (6426)"
|
|
::= { airIRmPmHumidifier1 27 }
|
|
|
|
airIRmPmHumidifier1CurrentValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 current value in percent (6427)"
|
|
::= { airIRmPmHumidifier1 28 }
|
|
|
|
airIRmPmHumidifier1ManOpValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 manual operation value in percent (6428)"
|
|
::= { airIRmPmHumidifier1 29 }
|
|
|
|
-- airIRmPmHumidifier2
|
|
|
|
airIRmPmHumidifier2ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 manual operation enable (6501)"
|
|
::= { airIRmPmHumidifier2 2 }
|
|
|
|
airIRmPmHumidifier2Running OBJECT-TYPE
|
|
SYNTAX AirIRmControlState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 running state (6502)"
|
|
::= { airIRmPmHumidifier2 3 }
|
|
|
|
airIRmPmHumidifier2ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 manual operation running state (6504)"
|
|
::= { airIRmPmHumidifier2 5 }
|
|
|
|
airIRmPmHumidifier2Type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
direct (1),
|
|
proportional (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 type (6516)"
|
|
::= { airIRmPmHumidifier2 17 }
|
|
|
|
airIRmPmHumidifier2StartHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 start humidity in tenths
|
|
of percent relative humidity (6517)"
|
|
::= { airIRmPmHumidifier2 18 }
|
|
|
|
airIRmPmHumidifier2Hysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 hysteresis in tenths
|
|
of percent relative humidity (6519)"
|
|
::= { airIRmPmHumidifier2 20 }
|
|
|
|
airIRmPmHumidifier2LinearRange OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 linear range in tenths
|
|
of percent relative humidity per Kelvin (6520)"
|
|
::= { airIRmPmHumidifier2 21 }
|
|
|
|
airIRmPmHumidifier2Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 runtime in hours (6526)"
|
|
::= { airIRmPmHumidifier2 27 }
|
|
|
|
airIRmPmHumidifier2CurrentValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 current value in percent (6527)"
|
|
::= { airIRmPmHumidifier2 28 }
|
|
|
|
airIRmPmHumidifier2ManOpValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 manual operation value in percent (6528)"
|
|
::= { airIRmPmHumidifier2 29 }
|
|
|
|
-- airIRmPmDehumidification
|
|
|
|
airIRmPmDehumidificManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dehumidifier manual operation enable setting (6801)"
|
|
::= { airIRmPmDehumidification 2 }
|
|
|
|
airIRmPmDehumidificRunning OBJECT-TYPE
|
|
SYNTAX AirIRmControlState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dehumidifier running state (6802)"
|
|
::= { airIRmPmDehumidification 3 }
|
|
|
|
airIRmPmDehumidificManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dehumidifier manual operation running (6804)"
|
|
::= { airIRmPmDehumidification 5 }
|
|
|
|
airIRmPmDehumidificStartHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dehumidifier start humidity in tenths of percent relative humidity (6809)"
|
|
::= { airIRmPmDehumidification 10 }
|
|
|
|
airIRmPmDehumidificHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dehumidifier hysteresis in tenths of percent relative humidity (6811)"
|
|
::= { airIRmPmDehumidification 12 }
|
|
|
|
airIRmPmDehumidificMinWaterTemp OBJECT IDENTIFIER ::= { airIRmPmDehumidification 18 }
|
|
airIRmPmDehumidificMinWaterTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dehumidifier minimum water temperature in tenths of
|
|
degrees Celsius (6817)"
|
|
::= { airIRmPmDehumidificMinWaterTemp 1 }
|
|
airIRmPmDehumidificMinWaterTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dehumidifier minimum water temperature in tenths of
|
|
degrees Fahrenheit (6817)"
|
|
::= { airIRmPmDehumidificMinWaterTemp 2 }
|
|
|
|
airIRmPmDehumidificMaxWaterTemp OBJECT IDENTIFIER ::= { airIRmPmDehumidification 19 }
|
|
airIRmPmDehumidificMaxWaterTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dehumidifier maximum water temperature in tenths of
|
|
degrees Celsius (6818)"
|
|
::= { airIRmPmDehumidificMaxWaterTemp 1 }
|
|
airIRmPmDehumidificMaxWaterTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dehumidifier maximum water temperature in tenths of
|
|
degrees Fahrenheit (6818)"
|
|
::= { airIRmPmDehumidificMaxWaterTemp 2 }
|
|
|
|
airIRmPmDehumidificRuntime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dehumidifier runtime in hours (6820)"
|
|
::= { airIRmPmDehumidification 21 }
|
|
|
|
-- airIRmPmFan1
|
|
|
|
airIRmPmFan1ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 manual operation enable (6901)"
|
|
::= { airIRmPmFan1 2 }
|
|
|
|
airIRmPmFan1Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 running (6902)"
|
|
::= { airIRmPmFan1 3 }
|
|
|
|
airIRmPmFan1ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 manual operation running (6905)"
|
|
::= { airIRmPmFan1 6 }
|
|
|
|
airIRmPmFan1Type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
direct (1),
|
|
proportional (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 type (6908)"
|
|
::= { airIRmPmFan1 9 }
|
|
|
|
airIRmPmFan1Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 runtime in hours (6931)"
|
|
::= { airIRmPmFan1 32 }
|
|
|
|
airIRmPmFan1Speed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 speed in percent (6932)"
|
|
::= { airIRmPmFan1 33 }
|
|
|
|
airIRmPmFan1ManOpSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 manual operation speed in percent (6933)"
|
|
::= { airIRmPmFan1 34 }
|
|
|
|
-- airIRmPmFan2
|
|
|
|
airIRmPmFan2ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 manual operation enable (7001)"
|
|
::= { airIRmPmFan2 2 }
|
|
|
|
airIRmPmFan2Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 running (7002)"
|
|
::= { airIRmPmFan2 3 }
|
|
|
|
airIRmPmFan2ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 manual operation running (7005)"
|
|
::= { airIRmPmFan2 6 }
|
|
|
|
airIRmPmFan2Type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
direct (1),
|
|
proportional (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 2 type (7008)"
|
|
::= { airIRmPmFan2 9 }
|
|
|
|
airIRmPmFan2Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 runtime in hours (7031)"
|
|
::= { airIRmPmFan2 32 }
|
|
|
|
airIRmPmFan2Speed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 speed in percent (7032)"
|
|
::= { airIRmPmFan2 33 }
|
|
|
|
airIRmPmFan2ManOpSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 manual operation speed in percent (7033)"
|
|
::= { airIRmPmFan2 34 }
|
|
|
|
-- airIRmPmFan3
|
|
|
|
airIRmPmFan3ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 manual operation enable (7101)"
|
|
::= { airIRmPmFan3 2 }
|
|
|
|
airIRmPmFan3Running OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 running (7102)"
|
|
::= { airIRmPmFan3 3 }
|
|
|
|
airIRmPmFan3ManOpRunning OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 manual operation running (7105)"
|
|
::= { airIRmPmFan3 6 }
|
|
|
|
airIRmPmFan3Type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
direct (1),
|
|
proportional (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 3 type (7108)"
|
|
::= { airIRmPmFan3 9 }
|
|
|
|
airIRmPmFan3Runtime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 runtime in hours (7131)"
|
|
::= { airIRmPmFan3 32 }
|
|
|
|
airIRmPmFan3Speed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 speed in percent (7132)"
|
|
::= { airIRmPmFan3 33 }
|
|
|
|
airIRmPmFan3ManOpSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan 1 manual operation speed in percent (7133)"
|
|
::= { airIRmPmFan3 34 }
|
|
|
|
-- airIRmPmLouver1
|
|
|
|
airIRmPmLouver1ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Louver 1 manual operation enable (7201)"
|
|
::= { airIRmPmLouver1 2 }
|
|
|
|
airIRmPmLouver1Position OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed (1),
|
|
open (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Louver 1 position (7202)"
|
|
::= { airIRmPmLouver1 3 }
|
|
|
|
airIRmPmLouver1ManOpPosition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed (1),
|
|
open (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Louver 1 manual operation position setting (7203)"
|
|
::= { airIRmPmLouver1 4 }
|
|
|
|
-- airIRmPmLouver2
|
|
|
|
airIRmPmLouver2ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Louver 2 manual operation enable (7301)"
|
|
::= { airIRmPmLouver2 2 }
|
|
|
|
airIRmPmLouver2Position OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed (1),
|
|
open (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Louver 2 position (7302)"
|
|
::= { airIRmPmLouver2 3 }
|
|
|
|
airIRmPmLouver2ManOpPosition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed (1),
|
|
open (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Louver 2 manual operation position setting (7303)"
|
|
::= { airIRmPmLouver2 4 }
|
|
|
|
-- airIRmPmLouver3
|
|
|
|
airIRmPmLouver3ManOpEnable OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Louver 3 manual operation enable (7401)"
|
|
::= { airIRmPmLouver3 2 }
|
|
|
|
airIRmPmLouver3Position OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed (1),
|
|
open (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Louver 3 position (7402)"
|
|
::= { airIRmPmLouver3 3 }
|
|
|
|
airIRmPmLouver3ManOpPosition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed (1),
|
|
open (2) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Louver 3 manual operation position setting (7403)"
|
|
::= { airIRmPmLouver3 4 }
|
|
|
|
-- airIRmPmAuxAlarm1
|
|
-- Empty
|
|
|
|
-- airIRmPmAuxAlarm2
|
|
-- Empty
|
|
|
|
-- airIRmPmAuxAlarm3
|
|
-- Empty
|
|
|
|
-- airIRmPmAuxAlarm4
|
|
-- Empty
|
|
|
|
-- airIRmPmAuxAlarm5
|
|
-- Empty
|
|
|
|
|
|
-- airIRmPmAlarmBits
|
|
|
|
airIRmPmFan1Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan #1 failure (8500)."
|
|
::= { airIRmPmAlarmBits 1 }
|
|
|
|
airIRmPmFan2Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan #2 failure (8501)."
|
|
::= { airIRmPmAlarmBits 2 }
|
|
|
|
airIRmPmFan3Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan #3 failure (8502)."
|
|
::= { airIRmPmAlarmBits 3 }
|
|
|
|
airIRmPmCompressor1Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor #1 failure (8503)."
|
|
::= { airIRmPmAlarmBits 4 }
|
|
|
|
airIRmPmCompressor2Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor #2 failure (8504)."
|
|
::= { airIRmPmAlarmBits 5 }
|
|
|
|
airIRmPmWaterDetector OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Water detector alarm (8505)."
|
|
::= { airIRmPmAlarmBits 6 }
|
|
|
|
airIRmPmPhaseFailure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Phase failure (8506)."
|
|
::= { airIRmPmAlarmBits 7 }
|
|
|
|
airIRmPmFireSmokeDetector OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fire/smoke detector (8507)."
|
|
::= { airIRmPmAlarmBits 8 }
|
|
|
|
airIRmPmReturnAirTemperatureTooHigh OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Return air temperature too high (8508)."
|
|
::= { airIRmPmAlarmBits 9 }
|
|
|
|
airIRmPmReturnAirHumidityTooHigh OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Return air humidity too high (8509)."
|
|
::= { airIRmPmAlarmBits 10 }
|
|
|
|
airIRmPmSupplyAirTemperatureTooHigh OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Supply air temperature too high (8510)."
|
|
::= { airIRmPmAlarmBits 11 }
|
|
|
|
airIRmPmSupplyAirHumidityTooHigh OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Supply air humidity too high (8511)."
|
|
::= { airIRmPmAlarmBits 12 }
|
|
|
|
airIRmPmWaterTemperatureTooHigh OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Water temperature too high (8512)."
|
|
::= { airIRmPmAlarmBits 13 }
|
|
|
|
airIRmPmReturnAirTemperatureTooLow OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Return air temperature too low (8513)."
|
|
::= { airIRmPmAlarmBits 14 }
|
|
|
|
airIRmPmReturnAirHumidityTooLow OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Return air humidity too low (8514)."
|
|
::= { airIRmPmAlarmBits 15 }
|
|
|
|
airIRmPmSupplyAirTemperatureTooLow OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Supply air temperature too low (8515)."
|
|
::= { airIRmPmAlarmBits 16 }
|
|
|
|
airIRmPmSupplyAirHumidityTooLow OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Supply air humidity too low (8516)."
|
|
::= { airIRmPmAlarmBits 17 }
|
|
|
|
airIRmPmWaterTemperatureTooLow OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Water temperature too low (8517)."
|
|
::= { airIRmPmAlarmBits 18 }
|
|
|
|
airIRmPmSensor1Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #1 failure (8518)."
|
|
::= { airIRmPmAlarmBits 19 }
|
|
|
|
airIRmPmSensor2Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #2 failure (8519)."
|
|
::= { airIRmPmAlarmBits 20 }
|
|
|
|
airIRmPmSensor3Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #3 failure (8520)."
|
|
::= { airIRmPmAlarmBits 21 }
|
|
|
|
airIRmPmSensor4Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #4 failure (8521)."
|
|
::= { airIRmPmAlarmBits 22 }
|
|
|
|
airIRmPmSensor5Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #5 failure (8522)."
|
|
::= { airIRmPmAlarmBits 23 }
|
|
|
|
airIRmPmSensor6Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #6 failure (8523)."
|
|
::= { airIRmPmAlarmBits 24 }
|
|
|
|
airIRmPmSensor7Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #7 failure (8524)."
|
|
::= { airIRmPmAlarmBits 25 }
|
|
|
|
airIRmPmSensor8Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #8 failure (8525)."
|
|
::= { airIRmPmAlarmBits 26 }
|
|
|
|
airIRmPmSensor9Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #9 failure (8526)."
|
|
::= { airIRmPmAlarmBits 27 }
|
|
|
|
airIRmPmSensor10Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #10 failure (8527)."
|
|
::= { airIRmPmAlarmBits 28 }
|
|
|
|
airIRmPmSensor11Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #11 failure (8528)."
|
|
::= { airIRmPmAlarmBits 29 }
|
|
|
|
airIRmPmSensor12Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #12 failure (8529)."
|
|
::= { airIRmPmAlarmBits 30 }
|
|
|
|
airIRmPmSensor13Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #13 failure (8530)."
|
|
::= { airIRmPmAlarmBits 31 }
|
|
|
|
airIRmPmSensor14Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #14 failure (8531)."
|
|
::= { airIRmPmAlarmBits 32 }
|
|
|
|
airIRmPmSensor15Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #15 failure (8532)."
|
|
::= { airIRmPmAlarmBits 33 }
|
|
|
|
airIRmPmSensor16Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #16 failure (8533)."
|
|
::= { airIRmPmAlarmBits 34 }
|
|
|
|
airIRmPmSensor17Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #17 failure (8534)."
|
|
::= { airIRmPmAlarmBits 35 }
|
|
|
|
airIRmPmSensor18Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #18 failure (8535)."
|
|
::= { airIRmPmAlarmBits 36 }
|
|
|
|
airIRmPmSensor19Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #19 failure (8536)."
|
|
::= { airIRmPmAlarmBits 37 }
|
|
|
|
airIRmPmSensor20Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #20 failure (8537)."
|
|
::= { airIRmPmAlarmBits 38 }
|
|
|
|
airIRmPmSensor21Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #21 failure (8538)."
|
|
::= { airIRmPmAlarmBits 39 }
|
|
|
|
airIRmPmSensor1Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #1 defect (8539)."
|
|
::= { airIRmPmAlarmBits 40 }
|
|
|
|
airIRmPmSensor2Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #2 defect (8540)."
|
|
::= { airIRmPmAlarmBits 41 }
|
|
|
|
airIRmPmSensor3Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #3 defect (8541)."
|
|
::= { airIRmPmAlarmBits 42 }
|
|
|
|
airIRmPmSensor4Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #4 defect (8542)."
|
|
::= { airIRmPmAlarmBits 43 }
|
|
|
|
airIRmPmSensor5Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #5 defect (8543)."
|
|
::= { airIRmPmAlarmBits 44 }
|
|
|
|
airIRmPmSensor6Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #6 defect (8544)."
|
|
::= { airIRmPmAlarmBits 45 }
|
|
|
|
airIRmPmSensor7Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #7 defect (8545)."
|
|
::= { airIRmPmAlarmBits 46 }
|
|
|
|
airIRmPmSensor8Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #8 defect (8546)."
|
|
::= { airIRmPmAlarmBits 47 }
|
|
|
|
airIRmPmSensor9Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #9 defect (8547)."
|
|
::= { airIRmPmAlarmBits 48 }
|
|
|
|
airIRmPmSensor10Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #10 defect (8548)."
|
|
::= { airIRmPmAlarmBits 49 }
|
|
|
|
airIRmPmSensor11Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #11 defect (8549)."
|
|
::= { airIRmPmAlarmBits 50 }
|
|
|
|
airIRmPmSensor12Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #12 defect (8550)."
|
|
::= { airIRmPmAlarmBits 51 }
|
|
|
|
airIRmPmSensor13Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #13 defect (8551)."
|
|
::= { airIRmPmAlarmBits 52 }
|
|
|
|
airIRmPmSensor14Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #14 defect (8552)."
|
|
::= { airIRmPmAlarmBits 53 }
|
|
|
|
airIRmPmSensor15Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #15 defect (8553)."
|
|
::= { airIRmPmAlarmBits 54 }
|
|
|
|
airIRmPmSensor16Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #16 defect (8554)."
|
|
::= { airIRmPmAlarmBits 55 }
|
|
|
|
airIRmPmSensor17Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #17 defect (8555)."
|
|
::= { airIRmPmAlarmBits 56 }
|
|
|
|
airIRmPmSensor18Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #18 defect (8556)"
|
|
::= { airIRmPmAlarmBits 57 }
|
|
|
|
airIRmPmSensor19Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #19 defect (8557)."
|
|
::= { airIRmPmAlarmBits 58 }
|
|
|
|
airIRmPmSensor20Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #20 defect (8558)."
|
|
::= { airIRmPmAlarmBits 59 }
|
|
|
|
airIRmPmSensor21Defect OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor #21 defect (8559)."
|
|
::= { airIRmPmAlarmBits 60 }
|
|
|
|
airIRmPmCompressor1Alarm OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor #1 alarm (8560)."
|
|
::= { airIRmPmAlarmBits 61 }
|
|
|
|
airIRmPmCompressor2Alarm OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor #2 alarm (8561)."
|
|
::= { airIRmPmAlarmBits 62 }
|
|
|
|
airIRmPmCompressor1LowPressure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor #1 low pressure (8562)."
|
|
::= { airIRmPmAlarmBits 63 }
|
|
|
|
airIRmPmCompressor2LowPressure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compressor #2 low pressure (8563)."
|
|
::= { airIRmPmAlarmBits 64 }
|
|
|
|
airIRmPmReheat1Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reheat #1 failure (8564)."
|
|
::= { airIRmPmAlarmBits 65 }
|
|
|
|
airIRmPmReheat2Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reheat #2 failure (8565)."
|
|
::= { airIRmPmAlarmBits 66 }
|
|
|
|
airIRmPmReheat3Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reheat #3 failure (8566)."
|
|
::= { airIRmPmAlarmBits 67 }
|
|
|
|
airIRmPmReheat4Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reheat #4 failure (8567)."
|
|
::= { airIRmPmAlarmBits 68 }
|
|
|
|
airIRmPmDrycooler1Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler #1 failure (8568)."
|
|
::= { airIRmPmAlarmBits 69 }
|
|
|
|
airIRmPmDrycooler2Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler #2 failure (8569)."
|
|
::= { airIRmPmAlarmBits 70 }
|
|
|
|
airIRmPmDrycooler3Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler #3 failure (8570)."
|
|
::= { airIRmPmAlarmBits 71 }
|
|
|
|
airIRmPmDrycooler4Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycooler #4 failure (8571)."
|
|
::= { airIRmPmAlarmBits 72 }
|
|
|
|
airIRmPmPump1Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump #1 failure (8572)."
|
|
::= { airIRmPmAlarmBits 73 }
|
|
|
|
airIRmPmPump2Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump #2 failure (8573)."
|
|
::= { airIRmPmAlarmBits 74 }
|
|
|
|
airIRmPmPump3Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump #3 failure (8574)."
|
|
::= { airIRmPmAlarmBits 75 }
|
|
|
|
airIRmPmPump4Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pump #4 failure (8575)."
|
|
::= { airIRmPmAlarmBits 76 }
|
|
|
|
airIRmPmHumidifier1Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 failure (8576)."
|
|
::= { airIRmPmAlarmBits 77 }
|
|
|
|
airIRmPmHumidifier2Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 failure (8577)."
|
|
::= { airIRmPmAlarmBits 78 }
|
|
|
|
airIRmPmHumidifier3Failure OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #3 failure (8578)."
|
|
::= { airIRmPmAlarmBits 79 }
|
|
|
|
airIRmPmHumidifier1Alarm5us OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 5us alarm (8579)."
|
|
::= { airIRmPmAlarmBits 80 }
|
|
|
|
airIRmPmHumidifier2Alarm5us OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 5us alarm (8580)."
|
|
::= { airIRmPmAlarmBits 81 }
|
|
|
|
airIRmPmHumidifier3Alarm5us OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #3 5us alarm (8581)."
|
|
::= { airIRmPmAlarmBits 82 }
|
|
|
|
airIRmPmHumidifier1Alarm20us OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #1 20us alarm (8582)."
|
|
::= { airIRmPmAlarmBits 83 }
|
|
|
|
airIRmPmHumidifier2Alarm20us OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #2 20us alarm (8583)."
|
|
::= { airIRmPmAlarmBits 84 }
|
|
|
|
airIRmPmHumidifier3Alarm20us OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidifier #3 20us alarm (8584)."
|
|
::= { airIRmPmAlarmBits 85 }
|
|
|
|
airIRmPmFan1Alarm OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan #1 alarm (8585)."
|
|
::= { airIRmPmAlarmBits 86 }
|
|
|
|
airIRmPmFan2Alarm OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan #2 alarm (8586)."
|
|
::= { airIRmPmAlarmBits 87 }
|
|
|
|
airIRmPmFan3Alarm OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan #3 alarm (8587)."
|
|
::= { airIRmPmAlarmBits 88 }
|
|
|
|
airIRmPmFilter1Clogged OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Filter #1 clogged (8588)."
|
|
::= { airIRmPmAlarmBits 89 }
|
|
|
|
airIRmPmFilter2Clogged OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Filter #2 clogged (8589)."
|
|
::= { airIRmPmAlarmBits 90 }
|
|
|
|
airIRmPmFilter3Clogged OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Filter #3 clogged (8590)."
|
|
::= { airIRmPmAlarmBits 91 }
|
|
|
|
airIRmPmAuxiliaryAlarm1 OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Auxiliary #1 alarm (8591)."
|
|
::= { airIRmPmAlarmBits 92 }
|
|
|
|
airIRmPmAuxiliaryAlarm2 OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Auxiliary #2 alarm (8592)."
|
|
::= { airIRmPmAlarmBits 93 }
|
|
|
|
airIRmPmAuxiliaryAlarm3 OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Auxiliary #3 alarm (8593)."
|
|
::= { airIRmPmAlarmBits 94 }
|
|
|
|
airIRmPmAuxiliaryAlarm4 OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Auxiliary #4 alarm (8594)."
|
|
::= { airIRmPmAlarmBits 95 }
|
|
|
|
airIRmPmAuxiliaryAlarm5 OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Auxiliary #5 alarm (8595)."
|
|
::= { airIRmPmAlarmBits 96 }
|
|
|
|
airIRmPmAuxiliaryAlarm6 OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Auxiliary #6 alarm (8596)."
|
|
::= { airIRmPmAlarmBits 97 }
|
|
|
|
airIRmPmAuxiliaryAlarm7 OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Auxiliary #7 alarm (8597)."
|
|
::= { airIRmPmAlarmBits 98 }
|
|
|
|
airIRmPmAuxiliaryAlarm8 OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Auxiliary #8 alarm (8598)."
|
|
::= { airIRmPmAlarmBits 99 }
|
|
|
|
airIRmPmAuxiliaryAlarm9 OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Auxiliary #9 alarm (8599)."
|
|
::= { airIRmPmAlarmBits 100 }
|
|
|
|
airIRmPmAuxiliaryAlarm10 OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Auxiliary #10 alarm (8600)."
|
|
::= { airIRmPmAlarmBits 101 }
|
|
|
|
airIRmPmHotGasHeatingAlarm OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hot gas heating alarm (8601)."
|
|
::= { airIRmPmAlarmBits 102 }
|
|
|
|
airIRmPmEEV1PressureSensorError OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"EEV1 pressure sensor error (8602)."
|
|
::= { airIRmPmAlarmBits 103 }
|
|
|
|
airIRmPmEEV1TemperatureSensorError OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"EEV1 temperature sensor error (8603)."
|
|
::= { airIRmPmAlarmBits 104 }
|
|
|
|
airIRmPmEEV1StepperMotorError OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"EEV1 stepper motor error (8604)."
|
|
::= { airIRmPmAlarmBits 105 }
|
|
|
|
airIRmPmEEV2PressureSensorError OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"EEV2 pressure sensor error (8605)."
|
|
::= { airIRmPmAlarmBits 106 }
|
|
|
|
airIRmPmEEV2TemperatureSensorError OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"EEV2 temperature sensor error (8606)."
|
|
::= { airIRmPmAlarmBits 107 }
|
|
|
|
airIRmPmEEV2StepperMotorError OBJECT-TYPE
|
|
SYNTAX AirIRmAlarmState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"EEV2 stepper motor error (8607)."
|
|
::= { airIRmPmAlarmBits 108 }
|
|
|
|
-- airIRmPmMyZone
|
|
|
|
airIRmPmMyZoneNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"My zone number (11700)."
|
|
::= { airIRmPmMyZone 1 }
|
|
|
|
airIRmPmMyZoneRoomTemperature OBJECT IDENTIFIER ::= { airIRmPmMyZone 2 }
|
|
airIRmPmMyZoneRoomTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"My zone room temperature in tenths of degrees Celsius (11701)."
|
|
::= { airIRmPmMyZoneRoomTemperature 1 }
|
|
airIRmPmMyZoneRoomTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"My zone room temperature in tenths of degrees Fahrenheit (11701)."
|
|
::= { airIRmPmMyZoneRoomTemperature 2 }
|
|
|
|
airIRmPmMyZoneRoomHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"My zone room humidity in tenths of %RH (11702)."
|
|
::= { airIRmPmMyZone 3 }
|
|
|
|
airIRmPmMyZoneSupplyTemperature OBJECT IDENTIFIER ::= { airIRmPmMyZone 4 }
|
|
airIRmPmMyZoneSupplyTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"My zone supply temperature in tenths of degrees Celsius (11703)."
|
|
::= { airIRmPmMyZoneSupplyTemperature 1 }
|
|
airIRmPmMyZoneSupplyTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"My zone supply temperature in tenths
|
|
of degrees Fahrenheit (11703)."
|
|
::= { airIRmPmMyZoneSupplyTemperature 2 }
|
|
|
|
airIRmPmMyZoneSupplyHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"My zone supply humidity in tenths of %RH (11704)."
|
|
::= { airIRmPmMyZone 5 }
|
|
|
|
airIRmPmMyZoneSequencingTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"My zone sequencing time in minutes (11705)."
|
|
::= { airIRmPmMyZone 6 }
|
|
|
|
airIRmPmMyZoneNumberOfErrorUnits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of error units in my zone (11706)."
|
|
::= { airIRmPmMyZone 7 }
|
|
|
|
airIRmPmMyZoneEmergencyTemperature OBJECT IDENTIFIER ::= { airIRmPmMyZone 8 }
|
|
airIRmPmMyZoneEmergencyTemperatureC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"My zone emergency temperature in tenths of degrees Celsius (11707)."
|
|
::= { airIRmPmMyZoneEmergencyTemperature 1 }
|
|
airIRmPmMyZoneEmergencyTemperatureF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"My zone emergency temperature in tenths
|
|
of degrees Fahrenheit (11707)."
|
|
::= { airIRmPmMyZoneEmergencyTemperature 2 }
|
|
|
|
airIRmPmMyZoneCWEnergySaveMode OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"My zone CW energy save mode (11708)."
|
|
::= { airIRmPmMyZone 9 }
|
|
|
|
-- airIRmPmGlobalZoneData
|
|
|
|
airIRmPmGlobalZoneDataEmergencyOpMode OBJECT-TYPE
|
|
SYNTAX AirIRmActivityState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Emergency operation mode (11800)."
|
|
::= { airIRmPmGlobalZoneData 1 }
|
|
|
|
-- End of AC InRoom
|
|
|
|
-- Begining of airIRGen3
|
|
|
|
-- ******************************************************************
|
|
--airIRG3 Ident Group
|
|
-- ******************************************************************
|
|
|
|
airIRG3IdentTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ident table size."
|
|
::= { airIRG3Ident 1 }
|
|
|
|
AirIRG3IdentEntry ::= SEQUENCE {
|
|
airIRG3IdentIndex INTEGER,
|
|
airIRG3IdentName DisplayString,
|
|
airIRG3IdentLocation DisplayString,
|
|
airIRG3IdentModelNumber DisplayString,
|
|
airIRG3IdentSerialNumber DisplayString,
|
|
airIRG3IdentFirmwareRevision DisplayString,
|
|
airIRG3IdentHardwareRevision DisplayString,
|
|
airIRG3IdentManufactureDate DisplayString,
|
|
airIRG3IdentRDUSysOID OBJECT IDENTIFIER,
|
|
airIRG3IdentCMSysOID OBJECT IDENTIFIER,
|
|
airIRG3IdentGroupSysOID OBJECT IDENTIFIER
|
|
}
|
|
|
|
airIRG3IdentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3IdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to get ident information of current RDU and its assigned CM's."
|
|
::= { airIRG3Ident 2 }
|
|
|
|
airIRG3IdentEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3IdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ident table entry."
|
|
INDEX { airIRG3IdentIndex}
|
|
::= { airIRG3IdentTable 1 }
|
|
|
|
airIRG3IdentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of ident table."
|
|
::= { airIRG3IdentEntry 1 }
|
|
|
|
airIRG3IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit name."
|
|
::= { airIRG3IdentEntry 2 }
|
|
|
|
airIRG3IdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit location."
|
|
::= { airIRG3IdentEntry 3 }
|
|
|
|
airIRG3IdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit model number."
|
|
::= { airIRG3IdentEntry 4 }
|
|
|
|
airIRG3IdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit serial number."
|
|
::= { airIRG3IdentEntry 5 }
|
|
|
|
airIRG3IdentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit firmware version."
|
|
::= { airIRG3IdentEntry 6 }
|
|
|
|
airIRG3IdentHardwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit controller hardware revision."
|
|
::= { airIRG3IdentEntry 7 }
|
|
|
|
airIRG3IdentManufactureDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the unit manufacture date."
|
|
::= { airIRG3IdentEntry 8 }
|
|
|
|
airIRG3IdentRDUSysOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID contains an OID path to the RDU data."
|
|
::= { airIRG3IdentEntry 9 }
|
|
|
|
airIRG3IdentCMSysOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID contains an OID path to the cooling module data."
|
|
::= { airIRG3IdentEntry 10 }
|
|
|
|
airIRG3IdentGroupSysOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID contains an OID path to the group data."
|
|
::= { airIRG3IdentEntry 11 }
|
|
|
|
|
|
|
|
-- ******************************************************************
|
|
-- airIRG3 Group Status
|
|
-- ******************************************************************
|
|
|
|
airIRG3GroupTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group table size."
|
|
::= { airIRG3Group 1 }
|
|
|
|
|
|
AirIRG3GroupStatusEntry ::= SEQUENCE {
|
|
airIRG3GroupStatusIndex INTEGER,
|
|
airIRG3GroupStatusCoolOutput INTEGER,
|
|
airIRG3GroupStatusCoolDemand INTEGER,
|
|
airIRG3GroupStatusAirFlowUS INTEGER,
|
|
airIRG3GroupStatusAirFlowMetric INTEGER,
|
|
airIRG3GroupStatusMaxRackInletTempUS INTEGER,
|
|
airIRG3GroupStatusMaxRackInletTempMetric INTEGER,
|
|
airIRG3GroupStatusMinRackInletTempUS INTEGER,
|
|
airIRG3GroupStatusMinRackInletTempMetric INTEGER,
|
|
airIRG3GroupStatusMaxReturnAirTempUS INTEGER,
|
|
airIRG3GroupStatusMaxReturnAirTempMetric INTEGER,
|
|
airIRG3GroupStatusMinReturnAirTempUS INTEGER,
|
|
airIRG3GroupStatusMinReturnAirTempMetric INTEGER,
|
|
airIRG3GroupStatusAvgSupplyTempUS INTEGER,
|
|
airIRG3GroupStatusAvgSupplyTempMetric INTEGER,
|
|
airIRG3GroupStatusAvgReturnTempUS INTEGER,
|
|
airIRG3GroupStatusAvgReturnTempMetric INTEGER,
|
|
airIRG3GroupStatusAvgFanSpeed INTEGER,
|
|
airIRG3GroupStatusAvgAirFlowUS INTEGER,
|
|
airIRG3GroupStatusAvgAirFlowMetric INTEGER,
|
|
airIRG3GroupStatusTotalAirFlowUS INTEGER,
|
|
airIRG3GroupStatusTotalAirFlowMetric INTEGER
|
|
}
|
|
|
|
airIRG3GroupStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3GroupStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to get group status information."
|
|
::= { airIRG3Group 2 }
|
|
|
|
airIRG3GroupStatusEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3GroupStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group staus table entry."
|
|
INDEX { airIRG3GroupStatusIndex}
|
|
::= { airIRG3GroupStatusTable 1 }
|
|
|
|
airIRG3GroupStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of group status table."
|
|
::= { airIRG3GroupStatusEntry 1 }
|
|
|
|
airIRG3GroupStatusCoolOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group cooling output in tenths of kilowatts (kW).
|
|
Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 2 }
|
|
|
|
airIRG3GroupStatusCoolDemand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group cooling demand in tenths of kilowatts (kW).
|
|
Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 3 }
|
|
|
|
airIRG3GroupStatusAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group air flow in cubic feet per minute (CFM).
|
|
Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 4 }
|
|
|
|
airIRG3GroupStatusAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group air flow in liters per second (L/s).
|
|
Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 5 }
|
|
|
|
airIRG3GroupStatusMaxRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum rack inlet temperature in tenths of
|
|
degrees Fahrenheit. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 6 }
|
|
|
|
airIRG3GroupStatusMaxRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum rack inlet temperature in tenths of
|
|
degrees Celsius. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 7 }
|
|
|
|
airIRG3GroupStatusMinRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum rack inlet temperature in tenths of
|
|
degrees Fahrenheit. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 8 }
|
|
|
|
airIRG3GroupStatusMinRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum rack inlet temperature in tenths of
|
|
degrees Celsius. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 9 }
|
|
|
|
airIRG3GroupStatusMaxReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum return air temperature in tenths of
|
|
degrees Fahrenheit. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 10 }
|
|
|
|
airIRG3GroupStatusMaxReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group maximum return air temperature in tenths of
|
|
degrees Celsius. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 11 }
|
|
|
|
airIRG3GroupStatusMinReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum return air temperature in tenths of
|
|
degrees Fahrenheit. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 12 }
|
|
|
|
airIRG3GroupStatusMinReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group minimum return air temperature in tenths of
|
|
degrees Celsius. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 13 }
|
|
|
|
airIRG3GroupStatusAvgSupplyTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group average supply air temperature in tenths of
|
|
degrees Fahrenheit. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 14 }
|
|
|
|
airIRG3GroupStatusAvgSupplyTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group average supply air temperature in tenths of
|
|
degrees Celsius. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 15 }
|
|
|
|
airIRG3GroupStatusAvgReturnTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group average return air temperature in tenths of
|
|
degrees Fahrenheit. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 16 }
|
|
|
|
airIRG3GroupStatusAvgReturnTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group average return air temperature in tenths of
|
|
degrees Celsius. Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 17 }
|
|
|
|
airIRG3GroupStatusAvgFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group average fan speed in revolutions per minute (RPM).
|
|
Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 18 }
|
|
|
|
airIRG3GroupStatusAvgAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group average air flow in cubic feet per minute (CFM).
|
|
Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 19 }
|
|
|
|
airIRG3GroupStatusAvgAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group average air flow in liters per second (L/s).
|
|
Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 20 }
|
|
|
|
airIRG3GroupStatusTotalAirFlowUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group total air flow in cubic feet per minute (CFM).
|
|
Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 21 }
|
|
|
|
airIRG3GroupStatusTotalAirFlowMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group total air flow in liters per second (L/s).
|
|
Returns (-1) if not supported."
|
|
::= { airIRG3GroupStatusEntry 22 }
|
|
|
|
|
|
|
|
-- ******************************************************************
|
|
--airIRG3 Group Setpoints
|
|
-- ******************************************************************
|
|
|
|
AirIRG3GroupSetpointsEntry ::= SEQUENCE {
|
|
airIRG3GroupSetpointsIndex INTEGER,
|
|
airIRG3GroupSetpointsCoolSetpointUS INTEGER,
|
|
airIRG3GroupSetpointsCoolSetpointMetric INTEGER,
|
|
airIRG3GroupSetpointsCoolDeadbandUS INTEGER,
|
|
airIRG3GroupSetpointsCoolDeadbandMetric INTEGER,
|
|
airIRG3GroupSetpointsFanSpeedPreference INTEGER,
|
|
airIRG3GroupSetpointsSupplyAirSetpointUS INTEGER,
|
|
airIRG3GroupSetpointsSupplyAirSetpointMetric INTEGER,
|
|
airIRG3GroupSetpointsAirFlowControl INTEGER,
|
|
airIRG3GroupSetpointsLightingOnTime INTEGER
|
|
}
|
|
|
|
airIRG3GroupSetpointsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3GroupSetpointsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access the group setpoints."
|
|
::= { airIRG3Group 3 }
|
|
|
|
airIRG3GroupSetpointsEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3GroupSetpointsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group setpoints table entry."
|
|
INDEX { airIRG3GroupSetpointsIndex}
|
|
::= { airIRG3GroupSetpointsTable 1 }
|
|
|
|
airIRG3GroupSetpointsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of group setpoints table."
|
|
::= { airIRG3GroupSetpointsEntry 1 }
|
|
|
|
airIRG3GroupSetpointsCoolSetpointUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3GroupSetpointsEntry 2 }
|
|
|
|
airIRG3GroupSetpointsCoolSetpointMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3GroupSetpointsEntry 3 }
|
|
|
|
airIRG3GroupSetpointsCoolDeadbandUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling deadband in tenths of
|
|
degrees Fahrenheit. Returns (-1) if not supported."
|
|
::= { airIRG3GroupSetpointsEntry 4 }
|
|
|
|
airIRG3GroupSetpointsCoolDeadbandMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group cooling deadband in tenths of
|
|
degrees Celsius. Returns (-1) if not supported."
|
|
::= { airIRG3GroupSetpointsEntry 5 }
|
|
|
|
airIRG3GroupSetpointsFanSpeedPreference OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low (1),
|
|
med-low (2),
|
|
med (3),
|
|
med-high (4),
|
|
high (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group preferred fan speed setting."
|
|
::= { airIRG3GroupSetpointsEntry 6 }
|
|
|
|
airIRG3GroupSetpointsSupplyAirSetpointUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3GroupSetpointsEntry 7 }
|
|
|
|
airIRG3GroupSetpointsSupplyAirSetpointMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group supply air setpoint in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3GroupSetpointsEntry 8 }
|
|
|
|
airIRG3GroupSetpointsAirFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
manual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group air flow control."
|
|
::= { airIRG3GroupSetpointsEntry 9 }
|
|
|
|
airIRG3GroupSetpointsLightingOnTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group lighting on time in minutes."
|
|
::= { airIRG3GroupSetpointsEntry 10 }
|
|
|
|
|
|
-- ******************************************************************
|
|
--airIRG3 Group Config
|
|
-- ******************************************************************
|
|
|
|
AirIRG3GroupConfigEntry ::= SEQUENCE {
|
|
airIRG3GroupConfigIndex INTEGER,
|
|
airIRG3GroupConfigNumberofCoolingUnits INTEGER,
|
|
airIRG3GroupConfigConfigurationType INTEGER,
|
|
airIRG3GroupConfigCapacityControlType INTEGER,
|
|
airIRG3GroupConfigFanSpeedControl INTEGER,
|
|
airIRG3GroupConfigCoolGainP INTEGER,
|
|
airIRG3GroupConfigCoolResetRateI INTEGER,
|
|
airIRG3GroupConfigCoolDerivativeD INTEGER,
|
|
airIRG3GroupConfigCoolPIDReset INTEGER,
|
|
airIRG3GroupConfigNumberofBackupUnits INTEGER,
|
|
airIRG3GroupConfigRuntimeBalancingEnable INTEGER,
|
|
airIRG3GroupConfigLoadAssistEnable INTEGER
|
|
}
|
|
|
|
airIRG3GroupConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3GroupConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access group configuration table."
|
|
::= { airIRG3Group 4 }
|
|
|
|
airIRG3GroupConfigEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3GroupConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group config table entry."
|
|
INDEX { airIRG3GroupConfigIndex}
|
|
::= { airIRG3GroupConfigTable 1 }
|
|
|
|
airIRG3GroupConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of group config table."
|
|
::= { airIRG3GroupConfigEntry 1 }
|
|
|
|
airIRG3GroupConfigNumberofCoolingUnits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of cooling units."
|
|
::= { airIRG3GroupConfigEntry 2 }
|
|
|
|
airIRG3GroupConfigConfigurationType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
racs (1),
|
|
spot (2),
|
|
in-row (3),
|
|
hacs (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group configuration type.
|
|
The spot configuration type is not supported.
|
|
Returns (-1) if not supported."
|
|
::= { airIRG3GroupConfigEntry 3 }
|
|
|
|
airIRG3GroupConfigCapacityControlType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
discrete (1),
|
|
proportional (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group capacity control. Returns (-1) if not supported."
|
|
::= { airIRG3GroupConfigEntry 4 }
|
|
|
|
airIRG3GroupConfigFanSpeedControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic (1),
|
|
manual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The group fan speed control."
|
|
::= { airIRG3GroupConfigEntry 5 }
|
|
|
|
airIRG3GroupConfigCoolGainP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The gain component of the PID in hundredths."
|
|
::= { airIRG3GroupConfigEntry 6 }
|
|
|
|
airIRG3GroupConfigCoolResetRateI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The integral component of the PID in hundredths."
|
|
::= { airIRG3GroupConfigEntry 7 }
|
|
|
|
airIRG3GroupConfigCoolDerivativeD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The derivative component of the PID in hundredths."
|
|
::= { airIRG3GroupConfigEntry 8 }
|
|
|
|
airIRG3GroupConfigCoolPIDReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
readBack (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Will reset the PID coefficients back to the factory defaults.
|
|
Readback is not supported, returns -1."
|
|
::= { airIRG3GroupConfigEntry 9 }
|
|
|
|
airIRG3GroupConfigNumberofBackupUnits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of backup units."
|
|
::= { airIRG3GroupConfigEntry 10 }
|
|
|
|
airIRG3GroupConfigRuntimeBalancingEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable runtime balancing feature."
|
|
::= { airIRG3GroupConfigEntry 11 }
|
|
|
|
airIRG3GroupConfigLoadAssistEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable load assist feature."
|
|
::= { airIRG3GroupConfigEntry 12 }
|
|
|
|
|
|
-- ***************************************
|
|
-- airIRG3 Alarm Status
|
|
-- ***************************************
|
|
|
|
airIRG3AlarmsTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active alarms in the airIRG3AlarmsTable."
|
|
::= { airIRG3Alarms 1 }
|
|
|
|
AirIRG3AlarmsEntry ::= SEQUENCE {
|
|
airIRG3AlarmsIndex INTEGER,
|
|
airIRG3AlarmsEventCode INTEGER,
|
|
airIRG3AlarmsDescription DisplayString
|
|
}
|
|
|
|
airIRG3AlarmsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3AlarmsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of active alarms for the device."
|
|
::= { airIRG3Alarms 2 }
|
|
|
|
airIRG3AlarmsEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3AlarmsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarms specification"
|
|
INDEX { airIRG3AlarmsIndex }
|
|
::= { airIRG3AlarmsTable 1 }
|
|
|
|
airIRG3AlarmsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm index."
|
|
::= { airIRG3AlarmsEntry 1 }
|
|
|
|
airIRG3AlarmsEventCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Event Code for the alarm. Returns (-1) if not supported."
|
|
::= { airIRG3AlarmsEntry 2 }
|
|
|
|
airIRG3AlarmsDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the alarm. Returns (-1) if not supported."
|
|
::= { airIRG3AlarmsEntry 3 }
|
|
|
|
-- ***************************************
|
|
-- airIRG3 RDU Status
|
|
-- ***************************************
|
|
|
|
airIRG3RDUTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU table size."
|
|
::= { airIRG3RDU 1 }
|
|
|
|
|
|
AirIRG3RDUStatusEntry ::= SEQUENCE {
|
|
airIRG3RDUStatusDeviceIndex INTEGER,
|
|
airIRG3RDUID DisplayString,
|
|
airIRG3RDUStatusOnReadyStandby INTEGER,
|
|
airIRG3RDUStatusOperatingMode INTEGER,
|
|
airIRG3RDUStatusLeadPump INTEGER,
|
|
airIRG3RDUStatusStartupDelay INTEGER,
|
|
airIRG3RDUStatusPumpChangeOverInterval INTEGER,
|
|
airIRG3RDUStatusStopOnLeakDetect INTEGER,
|
|
airIRG3RDUStatusPowerSource INTEGER,
|
|
airIRG3RDUStatusTotalRDUOutputPower INTEGER,
|
|
airIRG3RDUStatusInletWaterTempUS INTEGER,
|
|
airIRG3RDUStatusInletWaterTempMetric INTEGER,
|
|
airIRG3RDUStatusOutletWaterTempUS INTEGER,
|
|
airIRG3RDUStatusOutletWaterTempMetric INTEGER,
|
|
airIRG3RDUStatusCondenserSaturationTempUS INTEGER,
|
|
airIRG3RDUStatusCondenserSaturationTempMetric INTEGER,
|
|
airIRG3RDUStatusDewPointTempUS INTEGER,
|
|
airIRG3RDUStatusDewPointTempMetric INTEGER,
|
|
airIRG3RDUStatusPumpOutletTempUS INTEGER,
|
|
airIRG3RDUStatusPumpOutletTempMetric INTEGER,
|
|
airIRG3RDUStatusSubcoolerOutletTempUS INTEGER,
|
|
airIRG3RDUStatusSubcoolerOutletTempMetric INTEGER,
|
|
airIRG3RDUStatusCondenserOutletTempUS INTEGER,
|
|
airIRG3RDUStatusCondenserOutletTempMetric INTEGER,
|
|
airIRG3RDUStatusCondenserInletTempUS INTEGER,
|
|
airIRG3RDUStatusCondenserInletTempMetric INTEGER,
|
|
airIRG3RDUStatusCondenserOutletPressureUS INTEGER,
|
|
airIRG3RDUStatusCondenserOutletPressureMetric INTEGER,
|
|
airIRG3RDUStatusPump1HeadPressureUS INTEGER,
|
|
airIRG3RDUStatusPump1HeadPressureMetric INTEGER,
|
|
airIRG3RDUStatusPump2HeadPressureUS INTEGER,
|
|
airIRG3RDUStatusPump2HeadPressureMetric INTEGER,
|
|
airIRG3RDUStatusPump1Speed INTEGER,
|
|
airIRG3RDUStatusPump2Speed INTEGER,
|
|
airIRG3RDUStatusCWValvePosition INTEGER,
|
|
airIRG3RDUStatusReceiverLiquidLevel INTEGER,
|
|
airIRG3RDUStatusDCPowerSupply1Current INTEGER,
|
|
airIRG3RDUStatusDCPowerSupply2Current INTEGER,
|
|
airIRG3RDUStatusTotalDCPowerSupplyCurrent INTEGER,
|
|
airIRG3RDUStatusInputState INTEGER,
|
|
airIRG3RDUStatusOutputState INTEGER,
|
|
airIRG3RDUStatusByPassValvePosition INTEGER,
|
|
airIRG3RDUStatusRefrigerantLeakDetector INTEGER
|
|
}
|
|
|
|
airIRG3RDUStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3RDUStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access RDU status table."
|
|
::= { airIRG3RDU 2 }
|
|
|
|
airIRG3RDUStatusEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3RDUStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU status table entry."
|
|
INDEX { airIRG3RDUStatusDeviceIndex}
|
|
::= { airIRG3RDUStatusTable 1 }
|
|
|
|
airIRG3RDUStatusDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of RDU status table."
|
|
::= { airIRG3RDUStatusEntry 1 }
|
|
|
|
|
|
airIRG3RDUID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current RDU ID (1 to F).
|
|
Configured RDU only shall display ID, else return -1. "
|
|
::= { airIRG3RDUStatusEntry 2 }
|
|
|
|
|
|
airIRG3RDUStatusOnReadyStandby OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby (1),
|
|
ready (2),
|
|
on (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU current status."
|
|
::= { airIRG3RDUStatusEntry 3 }
|
|
|
|
|
|
airIRG3RDUStatusOperatingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby (1),
|
|
ready (2),
|
|
on (3),
|
|
stop (4),
|
|
maintenancemode (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU actual operating mode."
|
|
::= { airIRG3RDUStatusEntry 4 }
|
|
|
|
|
|
airIRG3RDUStatusLeadPump OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pump1 (1),
|
|
pump2 (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU lead pump."
|
|
::= { airIRG3RDUStatusEntry 5 }
|
|
|
|
|
|
airIRG3RDUStatusStartupDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU start up delay in seconds."
|
|
::= { airIRG3RDUStatusEntry 6 }
|
|
|
|
|
|
airIRG3RDUStatusPumpChangeOverInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU pump change over interval in days."
|
|
::= { airIRG3RDUStatusEntry 7 }
|
|
|
|
|
|
airIRG3RDUStatusStopOnLeakDetect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU status of stop on leak detect."
|
|
::= { airIRG3RDUStatusEntry 8 }
|
|
|
|
|
|
airIRG3RDUStatusPowerSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
singleFeed (1),
|
|
dualFeed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU power source status."
|
|
::= { airIRG3RDUStatusEntry 9 }
|
|
|
|
|
|
airIRG3RDUStatusTotalRDUOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU output power in tenths of kilowatts (kW)."
|
|
::= { airIRG3RDUStatusEntry 10 }
|
|
|
|
|
|
airIRG3RDUStatusInletWaterTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU inlet water temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3RDUStatusEntry 11 }
|
|
|
|
|
|
airIRG3RDUStatusInletWaterTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU inlet water temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3RDUStatusEntry 12 }
|
|
|
|
|
|
airIRG3RDUStatusOutletWaterTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU outlet water temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3RDUStatusEntry 13 }
|
|
|
|
|
|
airIRG3RDUStatusOutletWaterTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU outlet water temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3RDUStatusEntry 14 }
|
|
|
|
|
|
airIRG3RDUStatusCondenserSaturationTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU condenser saturation temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3RDUStatusEntry 15 }
|
|
|
|
|
|
airIRG3RDUStatusCondenserSaturationTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU condenser saturation temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3RDUStatusEntry 16 }
|
|
|
|
|
|
airIRG3RDUStatusDewPointTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU dew point temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3RDUStatusEntry 17 }
|
|
|
|
|
|
airIRG3RDUStatusDewPointTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU dew point temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3RDUStatusEntry 18 }
|
|
|
|
|
|
airIRG3RDUStatusPumpOutletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU pump outlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3RDUStatusEntry 19 }
|
|
|
|
|
|
airIRG3RDUStatusPumpOutletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU pump outlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3RDUStatusEntry 20 }
|
|
|
|
|
|
airIRG3RDUStatusSubcoolerOutletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU sub cooler outlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3RDUStatusEntry 21 }
|
|
|
|
|
|
airIRG3RDUStatusSubcoolerOutletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU sub cooler outlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3RDUStatusEntry 22 }
|
|
|
|
|
|
airIRG3RDUStatusCondenserOutletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU condenser outlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3RDUStatusEntry 23 }
|
|
|
|
|
|
airIRG3RDUStatusCondenserOutletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU condenser outlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3RDUStatusEntry 24 }
|
|
|
|
|
|
airIRG3RDUStatusCondenserInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU condenser inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3RDUStatusEntry 25 }
|
|
|
|
|
|
airIRG3RDUStatusCondenserInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU condenser inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3RDUStatusEntry 26 }
|
|
|
|
|
|
airIRG3RDUStatusCondenserOutletPressureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU condenser outlet pressure in
|
|
pounds per square inch (PSI)."
|
|
::= { airIRG3RDUStatusEntry 27 }
|
|
|
|
airIRG3RDUStatusCondenserOutletPressureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU condenser outlet pressure in kiloPascals (KPa)."
|
|
::= { airIRG3RDUStatusEntry 28 }
|
|
|
|
|
|
airIRG3RDUStatusPump1HeadPressureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Pump 1 head pressure in pounds per square inch (PSI)."
|
|
::= { airIRG3RDUStatusEntry 29 }
|
|
|
|
airIRG3RDUStatusPump1HeadPressureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Pump 1 head pressure in kiloPascals (KPa)."
|
|
::= { airIRG3RDUStatusEntry 30 }
|
|
|
|
airIRG3RDUStatusPump2HeadPressureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Pump 2 head pressure in pounds per square inch (PSI)."
|
|
::= { airIRG3RDUStatusEntry 31 }
|
|
|
|
airIRG3RDUStatusPump2HeadPressureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Pump 2 head pressure in kiloPascals (KPa)."
|
|
::= { airIRG3RDUStatusEntry 32 }
|
|
|
|
airIRG3RDUStatusPump1Speed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Pump 1 speed in revolutions per minute (RPM)."
|
|
::= { airIRG3RDUStatusEntry 33 }
|
|
|
|
|
|
airIRG3RDUStatusPump2Speed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Pump 2 speed in revolutions per minute (RPM)."
|
|
::= { airIRG3RDUStatusEntry 34 }
|
|
|
|
|
|
airIRG3RDUStatusCWValvePosition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU CW Valve position in % open"
|
|
::= { airIRG3RDUStatusEntry 35 }
|
|
|
|
|
|
airIRG3RDUStatusReceiverLiquidLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU receiver liquid level in % Full"
|
|
::= { airIRG3RDUStatusEntry 36 }
|
|
|
|
|
|
airIRG3RDUStatusDCPowerSupply1Current OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU DC Power Supply 1 Current in Amps"
|
|
::= { airIRG3RDUStatusEntry 37 }
|
|
|
|
|
|
airIRG3RDUStatusDCPowerSupply2Current OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU DC Power Supply 2 Current in Amps"
|
|
::= { airIRG3RDUStatusEntry 38 }
|
|
|
|
|
|
airIRG3RDUStatusTotalDCPowerSupplyCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Total DC Power Supply Current in Amps"
|
|
::= { airIRG3RDUStatusEntry 39 }
|
|
|
|
|
|
airIRG3RDUStatusInputState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Input state."
|
|
::= { airIRG3RDUStatusEntry 40 }
|
|
|
|
|
|
airIRG3RDUStatusOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Output state"
|
|
::= { airIRG3RDUStatusEntry 41 }
|
|
|
|
airIRG3RDUStatusByPassValvePosition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU By Pass Valve position in % open"
|
|
::= { airIRG3RDUStatusEntry 42 }
|
|
|
|
airIRG3RDUStatusRefrigerantLeakDetector OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
suspended (1),
|
|
calibrating (2),
|
|
operating (3),
|
|
disabled (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU refrigerant leak detector status."
|
|
::= { airIRG3RDUStatusEntry 43 }
|
|
|
|
|
|
-- ***************************************
|
|
-- airIRG3 RDU Run Hours
|
|
-- ***************************************
|
|
|
|
AirIRG3RDURunHoursEntry ::= SEQUENCE {
|
|
airIRG3RDURunHoursDeviceIndex INTEGER,
|
|
airIRG3RDURunHoursRDUID DisplayString,
|
|
airIRG3RDURunHoursPump1 INTEGER,
|
|
airIRG3RDURunHoursPump2 INTEGER,
|
|
airIRG3RDURunHoursPowerSupply1 INTEGER,
|
|
airIRG3RDURunHoursPowerSupply2 INTEGER
|
|
}
|
|
|
|
airIRG3RDURunHoursTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3RDURunHoursEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access RDU run hours table."
|
|
::= { airIRG3RDU 3 }
|
|
|
|
airIRG3RDURunHoursEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3RDURunHoursEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU run hours table entry."
|
|
INDEX { airIRG3RDURunHoursDeviceIndex}
|
|
::= { airIRG3RDURunHoursTable 1 }
|
|
|
|
airIRG3RDURunHoursDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of RDU run hours table."
|
|
::= { airIRG3RDURunHoursEntry 1 }
|
|
|
|
airIRG3RDURunHoursRDUID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current RDU ID (1 to F).
|
|
Configured RDU only shall display ID, else return -1. "
|
|
::= { airIRG3RDURunHoursEntry 2 }
|
|
|
|
airIRG3RDURunHoursPump1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU run hours of Pump 1."
|
|
::= { airIRG3RDURunHoursEntry 3 }
|
|
|
|
airIRG3RDURunHoursPump2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU run hours of Pump 2."
|
|
::= { airIRG3RDURunHoursEntry 4 }
|
|
|
|
airIRG3RDURunHoursPowerSupply1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU run hours of power supply 1."
|
|
::= { airIRG3RDURunHoursEntry 5 }
|
|
|
|
airIRG3RDURunHoursPowerSupply2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU run hours of power supply 2."
|
|
::= { airIRG3RDURunHoursEntry 6 }
|
|
|
|
|
|
-- ***************************************
|
|
-- airIRG3 RDU Service Intervals
|
|
-- ***************************************
|
|
|
|
AirIRG3RDUServiceIntervalsEntry ::= SEQUENCE {
|
|
airIRG3RDUServiceIntervalsDeviceIndex INTEGER,
|
|
airIRG3RDUServiceIntervalsRDUID DisplayString,
|
|
airIRG3RDUServiceIntervalsAirFilterInterval INTEGER,
|
|
airIRG3RDUServiceIntervalsAirFilterAlarm INTEGER
|
|
}
|
|
|
|
airIRG3RDUServiceIntervalsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3RDUServiceIntervalsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access RDU service intervals table."
|
|
::= { airIRG3RDU 4 }
|
|
|
|
airIRG3RDUServiceIntervalsEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3RDUServiceIntervalsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The service interval table entry."
|
|
INDEX { airIRG3RDUServiceIntervalsDeviceIndex}
|
|
::= { airIRG3RDUServiceIntervalsTable 1 }
|
|
|
|
airIRG3RDUServiceIntervalsDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of service interval table."
|
|
::= { airIRG3RDUServiceIntervalsEntry 1 }
|
|
|
|
airIRG3RDUServiceIntervalsRDUID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current RDU ID (1 to F).
|
|
Configured RDU only shall display ID, else return -1. "
|
|
::= { airIRG3RDUServiceIntervalsEntry 2 }
|
|
|
|
airIRG3RDUServiceIntervalsAirFilterInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU service interval for air filter in hours.
|
|
Returns -1 if not supported."
|
|
::= { airIRG3RDUServiceIntervalsEntry 3 }
|
|
|
|
|
|
airIRG3RDUServiceIntervalsAirFilterAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU service interval air filter alarm status.
|
|
Returns -1 if not supported."
|
|
::= { airIRG3RDUServiceIntervalsEntry 4 }
|
|
|
|
|
|
|
|
-- *******************************************
|
|
-- airIRG3 RDU Thresholds
|
|
-- Currently there are no thresholds for RDU
|
|
-- *******************************************
|
|
|
|
AirIRG3RDUThresholdsEntry ::= SEQUENCE {
|
|
airIRG3RDUThresholdsDeviceIndex INTEGER,
|
|
airIRG3RDUThresholdsRDUID DisplayString,
|
|
airIRG3RDUThresholdsEnteringFluidTempHighUS INTEGER,
|
|
airIRG3RDUThresholdsEnteringFluidTempHighMetric INTEGER
|
|
}
|
|
|
|
airIRG3RDUThresholdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3RDUThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access RDU thresholds table."
|
|
::= { airIRG3RDU 5 }
|
|
|
|
airIRG3RDUThresholdsEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3RDUThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU thresholds table entry."
|
|
INDEX { airIRG3RDUThresholdsDeviceIndex}
|
|
::= { airIRG3RDUThresholdsTable 1 }
|
|
|
|
airIRG3RDUThresholdsDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of RDU thresholds table."
|
|
::= { airIRG3RDUThresholdsEntry 1 }
|
|
|
|
airIRG3RDUThresholdsRDUID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current RDU ID (1 to F).
|
|
Configured RDU only shall display ID, else return -1. "
|
|
::= { airIRG3RDUThresholdsEntry 2 }
|
|
|
|
airIRG3RDUThresholdsEnteringFluidTempHighUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU threshold for entering fluid temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3RDUThresholdsEntry 3 }
|
|
|
|
|
|
airIRG3RDUThresholdsEnteringFluidTempHighMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU threshold for entering fluid temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3RDUThresholdsEntry 4 }
|
|
|
|
|
|
-- ***************************************
|
|
-- airIRG3 RDU Setpoints
|
|
-- ***************************************
|
|
|
|
AirIRG3RDUSetpointsEntry ::= SEQUENCE {
|
|
airIRG3RDUSetpointsDeviceIndex INTEGER
|
|
}
|
|
|
|
airIRG3RDUSetpointsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3RDUSetpointsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access RDU set points table."
|
|
::= { airIRG3RDU 6 }
|
|
|
|
airIRG3RDUSetpointsEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3RDUSetpointsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU set points table entry."
|
|
INDEX { airIRG3RDUSetpointsDeviceIndex}
|
|
::= { airIRG3RDUSetpointsTable 1 }
|
|
|
|
airIRG3RDUSetpointsDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of RDU set points table."
|
|
::= { airIRG3RDUSetpointsEntry 1 }
|
|
|
|
|
|
|
|
-- ***************************************
|
|
-- airIRG3 RDU Config
|
|
-- ***************************************
|
|
|
|
AirIRG3RDUConfigEntry ::= SEQUENCE {
|
|
airIRG3RDUConfigDeviceIndex INTEGER,
|
|
airIRG3RDUConfigRDUID DisplayString,
|
|
airIRG3RDUConfigStopOnLeakDetect INTEGER,
|
|
airIRG3RDUConfigStartupDelay INTEGER,
|
|
airIRG3RDUConfigPumpChangeOverInterval INTEGER,
|
|
airIRG3RDUConfigPowerSource INTEGER,
|
|
airIRG3RDUConfigOutputSource INTEGER,
|
|
airIRG3RDUConfigInputNormalState INTEGER,
|
|
airIRG3RDUConfigOutputNormalState INTEGER,
|
|
airIRG3RDUConfigByPassValveEnabled INTEGER,
|
|
airIRG3RDUConfigRefrigerantLeakDetectorEnabled INTEGER,
|
|
airIRG3RDUConfigCalibrateRefrigerantLeakDetector INTEGER,
|
|
airIRG3RDUConfigOnReadyStandby INTEGER
|
|
}
|
|
|
|
airIRG3RDUConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3RDUConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access RDU configuration table."
|
|
::= { airIRG3RDU 7 }
|
|
|
|
airIRG3RDUConfigEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3RDUConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU configuration table entry."
|
|
INDEX { airIRG3RDUConfigDeviceIndex}
|
|
::= { airIRG3RDUConfigTable 1 }
|
|
|
|
airIRG3RDUConfigDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of RDU configuration table."
|
|
::= { airIRG3RDUConfigEntry 1 }
|
|
|
|
airIRG3RDUConfigRDUID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current RDU ID (1 to F).
|
|
Configured RDU only shall display ID, else return -1. "
|
|
::= { airIRG3RDUConfigEntry 2 }
|
|
|
|
airIRG3RDUConfigStopOnLeakDetect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU stop on leak detect set."
|
|
::= { airIRG3RDUConfigEntry 3 }
|
|
|
|
|
|
airIRG3RDUConfigStartupDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU start up delay in seconds."
|
|
::= { airIRG3RDUConfigEntry 4 }
|
|
|
|
|
|
airIRG3RDUConfigPumpChangeOverInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU pump change over interval in days."
|
|
::= { airIRG3RDUConfigEntry 5 }
|
|
|
|
|
|
airIRG3RDUConfigPowerSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
singleFeed (1),
|
|
dualFeed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU power source."
|
|
::= { airIRG3RDUConfigEntry 6 }
|
|
|
|
|
|
airIRG3RDUConfigOutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
anyalarm (1),
|
|
onlycriticalalarms (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU output source."
|
|
::= { airIRG3RDUConfigEntry 7 }
|
|
|
|
|
|
airIRG3RDUConfigInputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Input Normal State."
|
|
::= { airIRG3RDUConfigEntry 8 }
|
|
|
|
|
|
airIRG3RDUConfigOutputNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Output Normal State."
|
|
::= { airIRG3RDUConfigEntry 9 }
|
|
|
|
|
|
airIRG3RDUConfigByPassValveEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU By Pass Valve Enabled State."
|
|
::= { airIRG3RDUConfigEntry 10 }
|
|
|
|
airIRG3RDUConfigRefrigerantLeakDetectorEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RDU Refrigerant Leak Detector Enabled State."
|
|
::= { airIRG3RDUConfigEntry 11 }
|
|
|
|
airIRG3RDUConfigCalibrateRefrigerantLeakDetector OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter allows to calibrate the RDU Refrigerant Leak Detector and is write only.
|
|
The read returns -1. Only 'yes' is supported."
|
|
::= { airIRG3RDUConfigEntry 12 }
|
|
|
|
airIRG3RDUConfigOnReadyStandby OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby (1),
|
|
ready (2),
|
|
on (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This parameter allows to configure RDU on/standby parameter.
|
|
Ready is currently not supported. If unsupported returns -1. "
|
|
::= { airIRG3RDUConfigEntry 13 }
|
|
|
|
|
|
-- ***************************************
|
|
-- airIRG3 CMStatus
|
|
-- ***************************************
|
|
|
|
airIRG3CMTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cooling module table size."
|
|
::= { airIRG3CM 1 }
|
|
|
|
|
|
AirIRG3CMStatusEntry ::= SEQUENCE {
|
|
airIRG3CMStatusDeviceIndex INTEGER,
|
|
airIRG3CMStatusCMID DisplayString,
|
|
airIRG3CMStatusOperatingMode INTEGER,
|
|
airIRG3CMStatusUnitType INTEGER,
|
|
airIRG3CMStatusRackInletTempUS INTEGER,
|
|
airIRG3CMStatusRackInletTempMetric INTEGER,
|
|
airIRG3CMStatusReturnAirTempUS INTEGER,
|
|
airIRG3CMStatusReturnAirTempMetric INTEGER,
|
|
airIRG3CMStatusLiquidTempUS INTEGER,
|
|
airIRG3CMStatusLiquidTempMetric INTEGER,
|
|
airIRG3CMStatusVaporTempUS INTEGER,
|
|
airIRG3CMStatusVaporTempMetric INTEGER,
|
|
airIRG3CMStatusEvaporatorTempUS INTEGER,
|
|
airIRG3CMStatusEvaporatorTempMetric INTEGER,
|
|
airIRG3CMStatusLiquidInletPressureUS INTEGER,
|
|
airIRG3CMStatusLiquidInletPressureMetric INTEGER,
|
|
airIRG3CMStatusVaporOutletPressureUS INTEGER,
|
|
airIRG3CMStatusVaporOutletPressureMetric INTEGER,
|
|
airIRG3CMStatusExpansionValvePosition INTEGER,
|
|
airIRG3CMStatusEPRValvePosition INTEGER,
|
|
airIRG3CMStatusLocalDisplayOnOffEnabled INTEGER,
|
|
airIRG3CMStatusAverageFanSpeed INTEGER
|
|
}
|
|
|
|
airIRG3CMStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3CMStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access CM status table."
|
|
::= { airIRG3CM 2 }
|
|
|
|
airIRG3CMStatusEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3CMStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM status table entry."
|
|
INDEX { airIRG3CMStatusDeviceIndex}
|
|
::= { airIRG3CMStatusTable 1 }
|
|
|
|
airIRG3CMStatusDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of CM status table."
|
|
::= { airIRG3CMStatusEntry 1 }
|
|
|
|
airIRG3CMStatusCMID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM ID (RDU Number - Group Number - CM Unit Number)."
|
|
::= { airIRG3CMStatusEntry 2 }
|
|
|
|
airIRG3CMStatusOperatingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standBy (1),
|
|
on (2),
|
|
idle (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current operating mode of the CM."
|
|
::= { airIRG3CMStatusEntry 3 }
|
|
|
|
|
|
airIRG3CMStatusUnitType OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
unconfigured (1),
|
|
oa (2),
|
|
ra (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current CM unit type."
|
|
::= { airIRG3CMStatusEntry 4 }
|
|
|
|
|
|
airIRG3CMStatusRackInletTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3CMStatusEntry 5 }
|
|
|
|
|
|
airIRG3CMStatusRackInletTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3CMStatusEntry 6 }
|
|
|
|
|
|
airIRG3CMStatusReturnAirTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM return air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3CMStatusEntry 7 }
|
|
|
|
|
|
airIRG3CMStatusReturnAirTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM return air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3CMStatusEntry 8 }
|
|
|
|
|
|
airIRG3CMStatusLiquidTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM liquid temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3CMStatusEntry 9 }
|
|
|
|
|
|
airIRG3CMStatusLiquidTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM liquid temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3CMStatusEntry 10 }
|
|
|
|
|
|
airIRG3CMStatusVaporTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM vapor temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3CMStatusEntry 11 }
|
|
|
|
|
|
airIRG3CMStatusVaporTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM vapor temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3CMStatusEntry 12 }
|
|
|
|
|
|
airIRG3CMStatusEvaporatorTempUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM saturation temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3CMStatusEntry 13 }
|
|
|
|
|
|
airIRG3CMStatusEvaporatorTempMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM saturation temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3CMStatusEntry 14 }
|
|
|
|
airIRG3CMStatusLiquidInletPressureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM Liquid Inlet pressure in pounds per square inch (PSI)."
|
|
::= { airIRG3CMStatusEntry 15 }
|
|
|
|
airIRG3CMStatusLiquidInletPressureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM Liquid Inlet pressure in kiloPascals (kPa)."
|
|
::= { airIRG3CMStatusEntry 16 }
|
|
|
|
airIRG3CMStatusVaporOutletPressureUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM Vapor Outlet pressure in pounds per square inch (PSI)."
|
|
::= { airIRG3CMStatusEntry 17 }
|
|
|
|
airIRG3CMStatusVaporOutletPressureMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM Vapor Outlet pressure in kiloPascals (kPa)."
|
|
::= { airIRG3CMStatusEntry 18 }
|
|
|
|
airIRG3CMStatusExpansionValvePosition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM expansion valve position in % open"
|
|
::= { airIRG3CMStatusEntry 19 }
|
|
|
|
|
|
airIRG3CMStatusEPRValvePosition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM Evaporator Pressure Regulator Valve Position
|
|
in tenths of percent open"
|
|
::= { airIRG3CMStatusEntry 20 }
|
|
|
|
|
|
airIRG3CMStatusLocalDisplayOnOffEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the on/off control on the CM local display."
|
|
::= { airIRG3CMStatusEntry 21 }
|
|
|
|
|
|
airIRG3CMStatusAverageFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM Average Fan Speed."
|
|
::= { airIRG3CMStatusEntry 22 }
|
|
|
|
|
|
-- ***************************************
|
|
-- airIRG3 CM Run Hours
|
|
-- ***************************************
|
|
|
|
AirIRG3CMRunHoursEntry ::= SEQUENCE {
|
|
airIRG3CMRunHoursDeviceIndex INTEGER,
|
|
airIRG3CMRunHoursCMID DisplayString,
|
|
airIRG3CMRunHoursFan1 INTEGER,
|
|
airIRG3CMRunHoursFan2 INTEGER,
|
|
airIRG3CMRunHoursFan3 INTEGER,
|
|
airIRG3CMRunHoursFan4 INTEGER,
|
|
airIRG3CMRunHoursFan5 INTEGER,
|
|
airIRG3CMRunHoursAirFilter INTEGER
|
|
}
|
|
|
|
airIRG3CMRunHoursTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3CMRunHoursEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access CM run hours table."
|
|
::= { airIRG3CM 3 }
|
|
|
|
airIRG3CMRunHoursEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3CMRunHoursEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM run hours table entry."
|
|
INDEX { airIRG3CMRunHoursDeviceIndex}
|
|
::= { airIRG3CMRunHoursTable 1 }
|
|
|
|
airIRG3CMRunHoursDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of CM run hours table."
|
|
::= { airIRG3CMRunHoursEntry 1 }
|
|
|
|
airIRG3CMRunHoursCMID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM ID (RDU Number - Group Number - CM Unit Number)."
|
|
::= { airIRG3CMRunHoursEntry 2 }
|
|
|
|
airIRG3CMRunHoursFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM run hours for Fan1.
|
|
Returns (-1) if not appilcable."
|
|
::= { airIRG3CMRunHoursEntry 3 }
|
|
|
|
airIRG3CMRunHoursFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM run hours for Fan2.
|
|
Returns (-1) if not appilcable."
|
|
::= { airIRG3CMRunHoursEntry 4 }
|
|
|
|
airIRG3CMRunHoursFan3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM run hours for Fan3.
|
|
Returns (-1) if not appilcable."
|
|
::= { airIRG3CMRunHoursEntry 5 }
|
|
|
|
airIRG3CMRunHoursFan4 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM run hours for Fan4.
|
|
Returns (-1) if not appilcable."
|
|
::= { airIRG3CMRunHoursEntry 6 }
|
|
|
|
airIRG3CMRunHoursFan5 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM run hours for Fan5.
|
|
Returns (-1) if not appilcable."
|
|
::= { airIRG3CMRunHoursEntry 7 }
|
|
|
|
airIRG3CMRunHoursAirFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM run hours for air filter."
|
|
::= { airIRG3CMRunHoursEntry 8 }
|
|
|
|
|
|
|
|
-- ***************************************
|
|
-- airIRG3 CM Service Intervals
|
|
-- ***************************************
|
|
|
|
AirIRG3CMServiceIntervalsEntry ::= SEQUENCE {
|
|
airIRG3CMServiceIntervalsDeviceIndex INTEGER,
|
|
airIRG3CMServiceIntervalsCMID DisplayString,
|
|
airIRG3CMServiceIntervalsAirFilterInterval INTEGER,
|
|
airIRG3CMServiceIntervalsAirFilterAlarm INTEGER
|
|
}
|
|
|
|
airIRG3CMServiceIntervalsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3CMServiceIntervalsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access CM service intervals table."
|
|
::= { airIRG3CM 4 }
|
|
|
|
airIRG3CMServiceIntervalsEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3CMServiceIntervalsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM service interval table entry."
|
|
INDEX { airIRG3CMServiceIntervalsDeviceIndex}
|
|
::= { airIRG3CMServiceIntervalsTable 1 }
|
|
|
|
airIRG3CMServiceIntervalsDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of CM service intervals table."
|
|
::= { airIRG3CMServiceIntervalsEntry 1 }
|
|
|
|
airIRG3CMServiceIntervalsCMID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM ID (RDU Number - Group Number - CM Unit Number)."
|
|
::= { airIRG3CMServiceIntervalsEntry 2 }
|
|
|
|
airIRG3CMServiceIntervalsAirFilterInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM service interval for air filter in weeks.
|
|
Supported only for RA. Returns -1 if not supported."
|
|
::= { airIRG3CMServiceIntervalsEntry 3 }
|
|
|
|
airIRG3CMServiceIntervalsAirFilterAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM service interval air filter alarm status.
|
|
Supported only for RA. Returns -1 if not supported."
|
|
::= { airIRG3CMServiceIntervalsEntry 4 }
|
|
|
|
|
|
-- ***************************************
|
|
-- airIRG3 CM Thresholds
|
|
-- ***************************************
|
|
|
|
AirIRG3CMThresholdsEntry ::= SEQUENCE {
|
|
airIRG3CMThresholdsDeviceIndex INTEGER,
|
|
airIRG3CMThresholdsCMID DisplayString,
|
|
airIRG3CMThresholdsRackInletTempHighUS INTEGER,
|
|
airIRG3CMThresholdsRackInletTempHighMetric INTEGER,
|
|
airIRG3CMThresholdsSupplyAirTempHighUS INTEGER,
|
|
airIRG3CMThresholdsSupplyAirTempHighMetric INTEGER,
|
|
airIRG3CMThresholdsReturnAirTempHighUS INTEGER,
|
|
airIRG3CMThresholdsReturnAirTempHighMetric INTEGER
|
|
}
|
|
|
|
airIRG3CMThresholdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3CMThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access CM thresholds table."
|
|
::= { airIRG3CM 5 }
|
|
|
|
airIRG3CMThresholdsEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3CMThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM thresholds table entry."
|
|
INDEX { airIRG3CMThresholdsDeviceIndex}
|
|
::= { airIRG3CMThresholdsTable 1 }
|
|
|
|
airIRG3CMThresholdsDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for CM thresholds table."
|
|
::= { airIRG3CMThresholdsEntry 1 }
|
|
|
|
airIRG3CMThresholdsCMID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM ID (RDU Number - Group Number - CM Unit Number)."
|
|
::= { airIRG3CMThresholdsEntry 2 }
|
|
|
|
airIRG3CMThresholdsRackInletTempHighUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM high threshold for rack inlet temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3CMThresholdsEntry 3 }
|
|
|
|
|
|
airIRG3CMThresholdsRackInletTempHighMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM high threshold for rack inlet temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3CMThresholdsEntry 4 }
|
|
|
|
|
|
airIRG3CMThresholdsSupplyAirTempHighUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM high threshold for supply air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3CMThresholdsEntry 5 }
|
|
|
|
|
|
airIRG3CMThresholdsSupplyAirTempHighMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM high threshold for supply air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3CMThresholdsEntry 6 }
|
|
|
|
|
|
airIRG3CMThresholdsReturnAirTempHighUS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM high threshold for return air temperature in tenths of
|
|
degrees Fahrenheit."
|
|
::= { airIRG3CMThresholdsEntry 7 }
|
|
|
|
|
|
airIRG3CMThresholdsReturnAirTempHighMetric OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM high threshold for return air temperature in tenths of
|
|
degrees Celsius."
|
|
::= { airIRG3CMThresholdsEntry 8 }
|
|
|
|
|
|
-- ***************************************
|
|
-- airIRG3 CM Setpoints
|
|
-- ***************************************
|
|
|
|
AirIRG3CMSetpointsEntry ::= SEQUENCE {
|
|
airIRG3CMSetpointsDeviceIndex INTEGER
|
|
}
|
|
|
|
airIRG3CMSetpointsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3CMSetpointsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access CM set points table."
|
|
::= { airIRG3CM 6 }
|
|
|
|
airIRG3CMSetpointsEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3CMSetpointsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM set points table entry."
|
|
INDEX { airIRG3CMSetpointsDeviceIndex}
|
|
::= { airIRG3CMSetpointsTable 1 }
|
|
|
|
airIRG3CMSetpointsDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of CM set points table."
|
|
::= { airIRG3CMSetpointsEntry 1 }
|
|
|
|
|
|
|
|
-- ***************************************
|
|
-- airIRG3 CM Config
|
|
-- ***************************************
|
|
|
|
AirIRG3CMConfigEntry ::= SEQUENCE {
|
|
airIRG3CMConfigDeviceIndex INTEGER,
|
|
airIRG3CMConfigCMID DisplayString,
|
|
airIRG3CMConfigStopOnCoolFail INTEGER,
|
|
airIRG3CMConfigStartupDelay INTEGER,
|
|
airIRG3CMConfigRemoteOnStandby INTEGER,
|
|
airIRG3CMConfigPowerSource INTEGER
|
|
}
|
|
|
|
airIRG3CMConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AirIRG3CMConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows to access CM configuration table."
|
|
::= { airIRG3CM 7 }
|
|
|
|
airIRG3CMConfigEntry OBJECT-TYPE
|
|
SYNTAX AirIRG3CMConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM configuration table entry."
|
|
INDEX { airIRG3CMConfigDeviceIndex}
|
|
::= { airIRG3CMConfigTable 1 }
|
|
|
|
airIRG3CMConfigDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index of CM configuration table."
|
|
::= { airIRG3CMConfigEntry 1 }
|
|
|
|
airIRG3CMConfigCMID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM ID (RDU Number - Group Number - CM Unit Number)."
|
|
::= { airIRG3CMConfigEntry 2 }
|
|
|
|
airIRG3CMConfigStopOnCoolFail OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/Disable Stop On cool fail. When enabled, stops the unit
|
|
if it detects that it is blowing warm air into the cold aisle."
|
|
::= { airIRG3CMConfigEntry 3 }
|
|
|
|
|
|
airIRG3CMConfigStartupDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM start up delay in seconds."
|
|
::= { airIRG3CMConfigEntry 4 }
|
|
|
|
|
|
airIRG3CMConfigRemoteOnStandby OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
standBy (1),
|
|
on (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM configuration for operating mode."
|
|
::= { airIRG3CMConfigEntry 5 }
|
|
|
|
|
|
airIRG3CMConfigPowerSource OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
singleFeed (1),
|
|
dualFeed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The CM power source."
|
|
::= { airIRG3CMConfigEntry 6 }
|
|
|
|
|
|
-- End of airIRGen3
|
|
|
|
|
|
-- RACK AIR REMOVAL UNIT IDENT
|
|
|
|
rARUIdentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RARUIdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for query of the individual devices.
|
|
The number of entries is contained in the
|
|
rARUStatusAruDeviceCount OID."
|
|
::= { rARUIdent 1 }
|
|
|
|
rARUIdentEntry OBJECT-TYPE
|
|
SYNTAX RARUIdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The device to query."
|
|
INDEX { rARUIdentAruIndex}
|
|
::= { rARUIdentTable 1 }
|
|
|
|
RARUIdentEntry ::=
|
|
SEQUENCE {
|
|
rARUIdentAruIndex INTEGER,
|
|
rARUIdentName DisplayString
|
|
}
|
|
|
|
rARUIdentAruIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the ARU entry."
|
|
::= { rARUIdentEntry 1 }
|
|
|
|
rARUIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the device. "
|
|
::= { rARUIdentEntry 2 }
|
|
|
|
-- RACK AIR REMOVAL UNIT CONFIGURATION
|
|
|
|
rARUConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RARUConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of the individual ARU devices accessible from this IP address.
|
|
The number of entries is contained in the rARUStatusAruDeviceCount OID."
|
|
::= { rARUConfig 1 }
|
|
|
|
rARUConfigEntry OBJECT-TYPE
|
|
SYNTAX RARUConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ARUs to configure."
|
|
INDEX { rARUConfigAruIndex }
|
|
::= { rARUConfigTable 1 }
|
|
|
|
RARUConfigEntry ::=
|
|
SEQUENCE {
|
|
rARUConfigAruIndex INTEGER,
|
|
rARUConfigAruName DisplayString,
|
|
rARUConfigAruRemoteSetpoint INTEGER,
|
|
rARUConfigAruTempOvrdEnableDisable INTEGER,
|
|
rARUConfigAruTempOvrdSetpoint INTEGER,
|
|
rARUConfigAruMasterControl INTEGER
|
|
}
|
|
|
|
rARUConfigAruIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the ARU entry."
|
|
::= { rARUConfigEntry 1 }
|
|
|
|
rARUConfigAruName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the ARU."
|
|
::= { rARUConfigEntry 2 }
|
|
|
|
rARUConfigAruRemoteSetpoint OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
aruOff (1),
|
|
aru85F-29C (2),
|
|
aru90F-32C (3),
|
|
aru95F-35C (4),
|
|
aru100F-38C (5),
|
|
aru7kW-1200cfm (6),
|
|
aru5kW-800cfm (7),
|
|
aru3kW-500cfm (8),
|
|
aru2kW-300cfm (9),
|
|
aru400cfm (10),
|
|
aru600cfm (11),
|
|
aru700cfm (12),
|
|
aru900cfm (13),
|
|
aru1000cfm (14),
|
|
aru1400cfm (15),
|
|
aru1600cfm (16),
|
|
aru1800cfm (17),
|
|
aru2000cfm (18)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID defines the desired base airflow of the ARU, and sets the
|
|
speed of the ARU fans when the temperature override is inactive.
|
|
|
|
Values specified in cfm (cubic feet per minute) can be converted
|
|
to metric values using the conversion factor:
|
|
|
|
1 cfm = 1.70 m^3/hr (cubic meters per hour).
|
|
|
|
Values (1) through (9) are for support of legacy (1st generation) ARUs.
|
|
Writing these values to a 2nd generation ARU will result in the following:
|
|
A value greater than (9) will be ignored by a 1st generation ARU.
|
|
|
|
aruOff (1) - Ignored
|
|
aru85F-29C (2) - 1200 cfm
|
|
aru90F-32C (3) - 800 cfm
|
|
aru95F-35C (4) - 500 cfm
|
|
aru100F-38C (5) - 400 cfm
|
|
aru7kW (6) - 1200 cfm
|
|
aru5kW (7) - 800 cfm
|
|
aru3kW (8) - 500 cfm
|
|
aru2kW (9) - 400 cfm
|
|
|
|
NOTE: -1 will be returned if the ARU is not communicating."
|
|
::= { rARUConfigEntry 3 }
|
|
|
|
rARUConfigAruTempOvrdEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID is used to enable/disable the remote temperature override setting of the ARU.
|
|
|
|
If this OID is set to 1, the remote setting for temperature override is disabled.
|
|
If this OID is set to 2, the remote setting for temperature override is enabled."
|
|
::= { rARUConfigEntry 4 }
|
|
|
|
rARUConfigAruTempOvrdSetpoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID is the Temperature Override setpoint of the ARU.
|
|
|
|
NOTE: -1 will be returned if the ARU is not communicating.
|
|
|
|
Values are represented in whole number degrees using the
|
|
units specified in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { rARUConfigEntry 5 }
|
|
|
|
rARUConfigAruMasterControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
aruOn (1),
|
|
aruOff (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the master on/off control for the ARU."
|
|
::= { rARUConfigEntry 6 }
|
|
|
|
-- RACK AIR REMOVAL UNIT STATUS
|
|
|
|
rARUStatusAruDeviceCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of ARUs accessible from this IP."
|
|
::= { rARUStatus 1 }
|
|
|
|
rARUStatusSysTempUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
celsius(1),
|
|
fahrenheit(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature scale used to display the temperature
|
|
in the system, Celsius(1) or Fahrenheit(2).
|
|
This setting is based on the system preferences
|
|
configuration in the agent."
|
|
::= { rARUStatus 2 }
|
|
|
|
rARUStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RARUStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for query of the individual ARUs accessible from this IP address.
|
|
The number of entries is contained in the rARUStatusAruDeviceCount OID."
|
|
::= { rARUStatus 3 }
|
|
|
|
rARUStatusEntry OBJECT-TYPE
|
|
SYNTAX RARUStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ARUs to access."
|
|
INDEX { rARUStatusAruIndex }
|
|
::= { rARUStatusTable 1 }
|
|
|
|
RARUStatusEntry ::=
|
|
SEQUENCE {
|
|
rARUStatusAruIndex INTEGER,
|
|
rARUStatusAruName DisplayString,
|
|
rARUStatusAruRemoteSetpoint INTEGER,
|
|
rARUStatusAruManualSetpoint INTEGER,
|
|
rARUStatusAruTemp1 INTEGER,
|
|
rARUStatusAruTemp2 INTEGER,
|
|
rARUStatusAruTemp3 INTEGER,
|
|
rARUStatusAruTempOvrdEnableDisable INTEGER,
|
|
rARUStatusAruTempOvrdSetpoint INTEGER,
|
|
rARUStatusAruAlarmState DisplayString,
|
|
rARUStatusAruCommStatus INTEGER,
|
|
rARUStatusAruTempOvrdStatus INTEGER,
|
|
rARUStatusAruMasterControl INTEGER,
|
|
rARUStatusAruTotalAirflow INTEGER
|
|
}
|
|
|
|
rARUStatusAruIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the ARU entry."
|
|
::= { rARUStatusEntry 1 }
|
|
|
|
rARUStatusAruName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the ARU."
|
|
::= { rARUStatusEntry 2 }
|
|
|
|
rARUStatusAruRemoteSetpoint OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
aruOff (1),
|
|
aru85F-29C (2),
|
|
aru90F-32C (3),
|
|
aru95F-35C (4),
|
|
aru100F-38C (5),
|
|
aru7kW-1200cfm (6),
|
|
aru5kW-800cfm (7),
|
|
aru3kW-500cfm (8),
|
|
aru2kW-300cfm (9),
|
|
aru400cfm (10),
|
|
aru600cfm (11),
|
|
aru700cfm (12),
|
|
aru900cfm (13),
|
|
aru1000cfm (14),
|
|
aru1400cfm (15),
|
|
aru1600cfm (16),
|
|
aru1800cfm (17),
|
|
aru2000cfm (18)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID defines the desired base airflow of the ARU, or the
|
|
speed of the ARU fans when the temperature override is inactive.
|
|
|
|
See also the rARUConfigAruRemoteSetpoint OID.
|
|
|
|
NOTE: -1 will be returned if the ARU is not communicating."
|
|
::= { rARUStatusEntry 3 }
|
|
|
|
rARUStatusAruManualSetpoint OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
aruOff (1),
|
|
aru85F-29C (2),
|
|
aru90F-32C (3),
|
|
aru95F-35C (4),
|
|
aru100F-38C (5),
|
|
aru7kW (6),
|
|
aru5kW (7),
|
|
aru3kW (8),
|
|
aru2kW (9),
|
|
aruRem (10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manual operating setpoint of the ARU, which is set on the
|
|
panel of the ARU. If the ARU doesn't have a manual ,
|
|
the OID will always return a value of aruRem (10).
|
|
|
|
NOTE: -1 will be returned if the ARU is not communicating.
|
|
|
|
Values are represented in whole number degrees or kW.
|
|
If the manual setpoint is set to Remote, or if the ARU doesn't
|
|
have a manual switch, this OID will return aruRem."
|
|
::= { rARUStatusEntry 4 }
|
|
|
|
rARUStatusAruTemp1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"ARU temperature probe #1 reading.
|
|
The summary exhaust temperature on 2nd generation ARUs.
|
|
|
|
NOTE: -1 will be returned if the ARU is not communicating.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { rARUStatusEntry 5 }
|
|
|
|
rARUStatusAruTemp2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"ARU temperature probe #2 reading.
|
|
The exhaust temperature in the upper plenum on 2nd generation ARUs.
|
|
|
|
NOTE: -1 will be returned if the ARU is not communicating.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { rARUStatusEntry 6 }
|
|
|
|
rARUStatusAruTemp3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"ARU temperature probe #3 reading.
|
|
The exhaust temperature in the lower plenum on 2nd generation ARUs.
|
|
|
|
NOTE: -1 will be returned if the ARU is not communicating.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { rARUStatusEntry 7 }
|
|
|
|
rARUStatusAruTempOvrdEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID indicates whether the ARU remote temperature override is enabled or disabled.
|
|
If this OID is a 1, the remote setting for temperature override is disabled.
|
|
If this OID is a 2, the remote setting for temperature override is enabled."
|
|
::= { rARUStatusEntry 8 }
|
|
|
|
rARUStatusAruTempOvrdSetpoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"ARU remote temperature override setpoint setting.
|
|
|
|
NOTE: -1 will be returned if the ARU is not communicating.
|
|
|
|
Values are represented in whole number degrees.
|
|
Units are displayed in the scale shown in
|
|
the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)."
|
|
::= { rARUStatusEntry 9 }
|
|
|
|
rARUStatusAruAlarmState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ASCII string containing the 8 flags representing
|
|
the current alarm state of the ARU. If the state of
|
|
the ARU is unknown, this variable is set to 'UNKNOWN'.
|
|
|
|
The flags are numbered 1 to 8, read from left to
|
|
right. The flags are defined as follows:
|
|
|
|
Flag 1: Fan Fail 1
|
|
Flag 2: Fan Fail 2
|
|
Flag 3: Fan Fail 3
|
|
Flag 4: Smoke (if ARU is equipped with smoke detector)
|
|
|
|
Flag 5: High Temp (Out of Thermal Control)
|
|
Flag 6: Over Temp (Exhaust Temp. Exceeds Override Setpoint)
|
|
Flag 7: Fan Fail 4 (Gen 2 ARU only)
|
|
Flag 8: Reserved"
|
|
::= { rARUStatusEntry 10 }
|
|
|
|
rARUStatusAruCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
commsNeverDiscovered(1),
|
|
commsEstablished(2),
|
|
commsLost(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of communications to the device.
|
|
commNeverDiscovered(1) indicates there has never been communications with this device.
|
|
commsEstablished(2) indicates communication is normal and active with this device.
|
|
commsLost(3) indicates communication had been established, but is no device."
|
|
::= { rARUStatusEntry 11 }
|
|
|
|
rARUStatusAruTempOvrdStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inactive (1),
|
|
active (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies whether the ARU is increasing airflow because
|
|
exhaust air temperature has exceeded the setting specified in the
|
|
rARUConfigAruTempOvrdSetpoint OID."
|
|
::= { rARUStatusEntry 12 }
|
|
|
|
rARUStatusAruMasterControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
aruOn (1),
|
|
aruOff (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the master on/off control for the ARU."
|
|
::= { rARUStatusEntry 13 }
|
|
|
|
rARUStatusAruTotalAirflow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total airflow provided by the aru. Specified in cfm (cubic feet per minute).
|
|
Can be converted to metric values using the conversion factor:
|
|
1 cfm = 1.70 m^3/hr (cubic meters per hour)."
|
|
::= { rARUStatusEntry 14 }
|
|
|
|
-- RACK AIR REMOVAL UNIT FAN STATUS
|
|
|
|
rARUFanStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RARUFanStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for query of the individual devices.
|
|
The number of entries is contained in the
|
|
rARUStatusAruDeviceCount OID."
|
|
::= { rARUFanStatus 1 }
|
|
|
|
rARUFanStatusEntry OBJECT-TYPE
|
|
SYNTAX RARUFanStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The device to query."
|
|
INDEX { rARUFanStatusAruIndex, rARUFanStatusFanIndex}
|
|
::= { rARUFanStatusTable 1 }
|
|
|
|
RARUFanStatusEntry ::=
|
|
SEQUENCE {
|
|
rARUFanStatusAruIndex INTEGER,
|
|
rARUFanStatusNominalFanSpeed INTEGER,
|
|
rARUFanStatusSelectedFanLevel INTEGER,
|
|
rARUFanStatusReplacementThreshold INTEGER,
|
|
rARUFanStatusFanIndex INTEGER,
|
|
rARUFanStatusFanOperatingStatus INTEGER,
|
|
rARUFanStatusFanRpmSpeed INTEGER,
|
|
rARUFanStatusFanFlowRate INTEGER,
|
|
rARUFanStatusFanInServiceDate DisplayString,
|
|
rARUFanStatusFanRunhourCounter INTEGER,
|
|
rARUFanStatusFanRunhourReset INTEGER
|
|
}
|
|
|
|
rARUFanStatusAruIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the ARU entry."
|
|
::= { rARUFanStatusEntry 1 }
|
|
|
|
rARUFanStatusNominalFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal rotational speed (RPM) of the fans when they are
|
|
operating at the 100% level."
|
|
::= { rARUFanStatusEntry 2 }
|
|
|
|
rARUFanStatusSelectedFanLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The currently selected ARU speed level,
|
|
specified in percent of full capacity."
|
|
::= { rARUFanStatusEntry 3 }
|
|
|
|
rARUFanStatusReplacementThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
khr20 (2),
|
|
khr25 (3),
|
|
khr30 (4),
|
|
khr35 (5),
|
|
khr40 (6),
|
|
khr50 (7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Threshold above which a run hour alarm will exist, indicating
|
|
that it might be time to proactively replace a fan."
|
|
::= { rARUFanStatusEntry 4 }
|
|
|
|
rARUFanStatusFanIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to an individual fan table entry."
|
|
::= { rARUFanStatusEntry 5 }
|
|
|
|
rARUFanStatusFanOperatingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
off (2),
|
|
onOk (3),
|
|
onDegraded (4),
|
|
offFailed (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current operating state of the fan."
|
|
::= { rARUFanStatusEntry 6 }
|
|
|
|
rARUFanStatusFanRpmSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current rotational speed of the fan,
|
|
specified in rotations per minute (RPM)."
|
|
::= { rARUFanStatusEntry 7 }
|
|
|
|
rARUFanStatusFanFlowRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The flow rate provided by the fan, based on its measured rotational speed.
|
|
Specified in cfm (cubic feet per minute). Can be converted to metric values
|
|
using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour)."
|
|
::= { rARUFanStatusEntry 8 }
|
|
|
|
rARUFanStatusFanInServiceDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The installation/replacement date of the fan."
|
|
::= { rARUFanStatusEntry 9 }
|
|
|
|
rARUFanStatusFanRunhourCounter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total time for which the fan has been running.
|
|
Specified in 10ths of hours."
|
|
::= { rARUFanStatusEntry 10 }
|
|
|
|
rARUFanStatusFanRunhourReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing yes to this This OID will reset a fan's total run hour counter,
|
|
which is shown in the rARUFanStatusFanRunhourCounter OID."
|
|
::= { rARUFanStatusEntry 11 }
|
|
|
|
-- RACK AIR REMOVAL UNIT INPUT POWER STATUS
|
|
|
|
rARUPowerStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RARUPowerStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for query of the individual ARUs accessible from this IP address.
|
|
The number of entries is contained in the rARUStatusAruDeviceCount OID."
|
|
::= { rARUPower 1 }
|
|
|
|
rARUPowerStatusEntry OBJECT-TYPE
|
|
SYNTAX RARUPowerStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The device to query."
|
|
INDEX { rARUPowerStatusAruIndex}
|
|
::= { rARUPowerStatusTable 1 }
|
|
|
|
RARUPowerStatusEntry ::=
|
|
SEQUENCE {
|
|
rARUPowerStatusAruIndex INTEGER,
|
|
rARUPowerStatusPrimaryAcPresent INTEGER,
|
|
rARUPowerStatusAuxiliaryAcPresent INTEGER,
|
|
rARUPowerStatusRedundantAcConfig INTEGER
|
|
}
|
|
|
|
rARUPowerStatusAruIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the ARU entry."
|
|
::= { rARUPowerStatusEntry 1 }
|
|
|
|
rARUPowerStatusPrimaryAcPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not line voltage is present on AC input 1."
|
|
::= { rARUPowerStatusEntry 2 }
|
|
|
|
rARUPowerStatusAuxiliaryAcPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not line voltage is present on AC input 2."
|
|
::= { rARUPowerStatusEntry 3 }
|
|
|
|
rARUPowerStatusRedundantAcConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
singleCord (1),
|
|
dualCord (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not a dual cord is in use.
|
|
When this setting is set to dualCord (2), aruRedundantPowerLostAlarm
|
|
traps will be generated when either primary or auxiliary input
|
|
voltage is not present. When this setting is set to singleCord (1),
|
|
aruRedundantPowerLostAlarm traps will not be generated."
|
|
::= { rARUPowerStatusEntry 4 }
|
|
|
|
-- RACK AIR REMOVAL UNIT SENSOR STATUS
|
|
|
|
rARUSensorsStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the rARUSensorsStatusTable."
|
|
::= { rARUSensors 1 }
|
|
|
|
rARUSensorsStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RARUSensorsStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting environmental sensor status information."
|
|
::= { rARUSensors 2 }
|
|
|
|
rARUSensorsStatusEntry OBJECT-TYPE
|
|
SYNTAX RARUSensorsStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { rARUSensorsStatusAruIndex, rARUSensorsStatusSensorNumber }
|
|
::= { rARUSensorsStatusTable 1 }
|
|
|
|
RARUSensorsStatusEntry ::=
|
|
SEQUENCE {
|
|
rARUSensorsStatusAruIndex INTEGER,
|
|
rARUSensorsStatusSensorNumber INTEGER,
|
|
rARUSensorsTemperature INTEGER
|
|
}
|
|
|
|
rARUSensorsStatusAruIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the ARU entry."
|
|
::= { rARUSensorsStatusEntry 1 }
|
|
|
|
rARUSensorsStatusSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the sensor on the device."
|
|
::= { rARUSensorsStatusEntry 2 }
|
|
|
|
rARUSensorsTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor's current temperature reading. The temperature scale
|
|
is based on the system preferences configuration."
|
|
::= { rARUSensorsStatusEntry 3 }
|
|
|
|
|
|
-- RACK AIR REMOVAL UNIT CONFIG STATUS
|
|
|
|
rARUSensorsConfigTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the rARUSensorsConfigTable."
|
|
::= { rARUSensors 3 }
|
|
|
|
rARUSensorsConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RARUSensorsConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting configuration information from
|
|
environmental sensors attached to the device."
|
|
::= { rARUSensors 4 }
|
|
|
|
rARUSensorsConfigEntry OBJECT-TYPE
|
|
SYNTAX RARUSensorsConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit to get data from."
|
|
INDEX { rARUSensorsConfigAruIndex, rARUSensorsConfigSensorNumber }
|
|
::= { rARUSensorsConfigTable 1 }
|
|
|
|
RARUSensorsConfigEntry ::=
|
|
SEQUENCE {
|
|
rARUSensorsConfigAruIndex INTEGER,
|
|
rARUSensorsConfigSensorNumber INTEGER,
|
|
rARUSensorsName DisplayString,
|
|
rARUSensorsLocation DisplayString,
|
|
rARUSensorsTempMaxThresh INTEGER,
|
|
rARUSensorsTempHighThresh INTEGER,
|
|
rARUSensorsTempLowThresh INTEGER,
|
|
rARUSensorsTempMinThresh INTEGER,
|
|
rARUSensorsTempThreshHysteresis INTEGER,
|
|
rARUSensorsTempShortDecRateThreshValue INTEGER,
|
|
rARUSensorsTempShortDecRateThreshTime INTEGER,
|
|
rARUSensorsTempShortIncRateThreshValue INTEGER,
|
|
rARUSensorsTempShortIncRateThreshTime INTEGER,
|
|
rARUSensorsTempLongDecRateThreshValue INTEGER,
|
|
rARUSensorsTempLongDecRateThreshTime INTEGER,
|
|
rARUSensorsTempLongIncRateThreshValue INTEGER,
|
|
rARUSensorsTempLongIncRateThreshTime INTEGER
|
|
}
|
|
|
|
rARUSensorsConfigAruIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the ARU entry."
|
|
::= { rARUSensorsConfigEntry 1 }
|
|
|
|
rARUSensorsConfigSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the sensor on the device."
|
|
::= { rARUSensorsConfigEntry 2 }
|
|
|
|
rARUSensorsName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive name for the sensor."
|
|
::= { rARUSensorsConfigEntry 3 }
|
|
|
|
rARUSensorsLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the sensor."
|
|
::= { rARUSensorsConfigEntry 4 }
|
|
|
|
rARUSensorsTempMaxThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature at which a maximum temperature threshold
|
|
violation alarm will be generated for this sensor.
|
|
The temperature scale is based on the system preferences
|
|
configuration."
|
|
::= { rARUSensorsConfigEntry 5 }
|
|
|
|
rARUSensorsTempHighThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature at which a high temperature threshold
|
|
violation alarm will be generated for this sensor.
|
|
The temperature scale is based on the system preferences
|
|
configuration."
|
|
::= { rARUSensorsConfigEntry 6 }
|
|
|
|
rARUSensorsTempLowThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature at which a low temperature threshold
|
|
violation alarm will be generated for this sensor.
|
|
The temperature scale is based on the system preferences
|
|
configuration."
|
|
::= { rARUSensorsConfigEntry 7 }
|
|
|
|
rARUSensorsTempMinThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature at which a min temperature threshold
|
|
violation alarm will be generated for this sensor.
|
|
The temperature scale is based on the system preferences
|
|
configuration."
|
|
::= { rARUSensorsConfigEntry 8 }
|
|
|
|
rARUSensorsTempThreshHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The change in temperature required to cause a
|
|
temperature alarm to change from an active to an
|
|
inactive state. The temperature scale is based on
|
|
the system preferences configuration."
|
|
::= { rARUSensorsConfigEntry 9 }
|
|
|
|
rARUSensorsTempShortDecRateThreshValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the temperature short-term decreasing rate
|
|
time that will cause an alarm to be generated.
|
|
The temperature scale is based on the system preferences
|
|
configuration."
|
|
::= { rARUSensorsConfigEntry 10 }
|
|
|
|
rARUSensorsTempShortDecRateThreshTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time over which the temperature may not decrease
|
|
beyond the value specified by the temperature short-term
|
|
decreasing rate threshold value."
|
|
::= { rARUSensorsConfigEntry 11 }
|
|
|
|
rARUSensorsTempShortIncRateThreshValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the temperature short-term increasing rate
|
|
time that will cause an alarm to be generated.
|
|
The temperature scale is based on the system preferences
|
|
configuration."
|
|
::= { rARUSensorsConfigEntry 12 }
|
|
|
|
rARUSensorsTempShortIncRateThreshTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time over which the temperature may not increase
|
|
beyond the value specified by the temperature short-term
|
|
increasing rate threshold value."
|
|
::= { rARUSensorsConfigEntry 13 }
|
|
|
|
rARUSensorsTempLongDecRateThreshValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the temperature long-term decreasing rate
|
|
time that will cause an alarm to be generated.
|
|
The temperature scale is based on the system preferences
|
|
configuration."
|
|
::= { rARUSensorsConfigEntry 14 }
|
|
|
|
rARUSensorsTempLongDecRateThreshTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time over which the temperature may not decrease
|
|
beyond the value specified by the temperature long-term
|
|
decreasing rate threshold value."
|
|
::= { rARUSensorsConfigEntry 15 }
|
|
|
|
rARUSensorsTempLongIncRateThreshValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the temperature long-term increasing rate
|
|
time that will cause an alarm to be generated.
|
|
The temperature scale is based on the system preferences
|
|
configuration."
|
|
::= { rARUSensorsConfigEntry 16 }
|
|
|
|
rARUSensorsTempLongIncRateThreshTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time over which the temperature may not increase
|
|
beyond the value specified by the temperature long-term
|
|
increasing rate threshold value."
|
|
::= { rARUSensorsConfigEntry 17 }
|
|
|
|
-- MODULAR DISTRIBUTION SYSTEM
|
|
|
|
-- Modular Information
|
|
|
|
isxModularDistInfoTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the isxModularDistInfoTable."
|
|
::= { isxModularDistInfo 1 }
|
|
|
|
isxModularDistInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IsxModularDistInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information about the modular
|
|
distribution metering equipment."
|
|
::= { isxModularDistInfo 2 }
|
|
|
|
isxModularDistInfoEntry OBJECT-TYPE
|
|
SYNTAX IsxModularDistInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information about an individual metering segment."
|
|
INDEX { isxModularDistInfoSegmentIndex }
|
|
::= { isxModularDistInfoTable 1 }
|
|
|
|
IsxModularDistInfoEntry ::=
|
|
SEQUENCE {
|
|
isxModularDistInfoSegmentIndex INTEGER,
|
|
isxModularDistInfoMeterModelNumber DisplayString,
|
|
isxModularDistInfoMeterSerialNumber DisplayString,
|
|
isxModularDistInfoMeterDateOfManufacture DisplayString,
|
|
isxModularDistInfoMeterFirmwareRev DisplayString,
|
|
isxModularDistInfoMeterHardwareRev DisplayString
|
|
}
|
|
|
|
isxModularDistInfoSegmentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the metering segment."
|
|
::= { isxModularDistInfoEntry 1 }
|
|
|
|
isxModularDistInfoMeterModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The model number of the metering board for this segment."
|
|
::= { isxModularDistInfoEntry 2 }
|
|
|
|
isxModularDistInfoMeterSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the metering board for this segment."
|
|
::= { isxModularDistInfoEntry 3 }
|
|
|
|
isxModularDistInfoMeterDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of manufacture for the metering board for this segment,
|
|
in the format mm/dd/yyyy."
|
|
::= { isxModularDistInfoEntry 4 }
|
|
|
|
isxModularDistInfoMeterFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision number of the metering board for this segment."
|
|
::= { isxModularDistInfoEntry 5 }
|
|
|
|
isxModularDistInfoMeterHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision number of the metering board for this segment."
|
|
::= { isxModularDistInfoEntry 6 }
|
|
|
|
-- Distribution Modules
|
|
|
|
isxModularDistModuleInfoTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the isxModularDistModuleInfoTable."
|
|
::= { isxModularDistModules 1 }
|
|
|
|
isxModularDistModuleInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IsxModularDistModuleInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting basic information about the distribution modules
|
|
installed in the system."
|
|
::= { isxModularDistModules 2 }
|
|
|
|
isxModularDistModuleInfoEntry OBJECT-TYPE
|
|
SYNTAX IsxModularDistModuleInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information about a specific distribution module."
|
|
INDEX { isxModularDistModuleInfoModIndex }
|
|
::= { isxModularDistModuleInfoTable 1 }
|
|
|
|
IsxModularDistModuleInfoEntry ::=
|
|
SEQUENCE {
|
|
isxModularDistModuleInfoModIndex INTEGER,
|
|
isxModularDistModuleInfoAlarmStatus INTEGER,
|
|
isxModularDistModuleInfoModelNumber DisplayString,
|
|
isxModularDistModuleInfoSerialNumber DisplayString,
|
|
isxModularDistModuleInfoDateOfManufacture DisplayString,
|
|
isxModularDistModuleInfoNumCables INTEGER
|
|
}
|
|
|
|
isxModularDistModuleInfoModIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the distribution module."
|
|
::= { isxModularDistModuleInfoEntry 1 }
|
|
|
|
isxModularDistModuleInfoAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
warning (2),
|
|
critical (3),
|
|
notPresent (4),
|
|
unknown (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of this module. This reflects the indicator lamp(s) on the front of the module.
|
|
A value of notPresent indicates that the module is not installed.
|
|
A value of unknown indicates that there is no communication with the
|
|
metering segment for this module."
|
|
::= { isxModularDistModuleInfoEntry 2 }
|
|
|
|
isxModularDistModuleInfoModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The model number of the distribution module."
|
|
::= { isxModularDistModuleInfoEntry 3 }
|
|
|
|
isxModularDistModuleInfoSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the distribution module."
|
|
::= { isxModularDistModuleInfoEntry 4 }
|
|
|
|
isxModularDistModuleInfoDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date that the distribution module was manufactured."
|
|
::= { isxModularDistModuleInfoEntry 5 }
|
|
|
|
isxModularDistModuleInfoNumCables OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of cables provided by this distribution module."
|
|
::= { isxModularDistModuleInfoEntry 6 }
|
|
|
|
isxModularDistModuleBreakerTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the isxModularDistModuleBreakerTable."
|
|
::= { isxModularDistModules 3 }
|
|
|
|
isxModularDistModuleBreakerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IsxModularDistModuleBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting operational information about the distribution modules."
|
|
::= { isxModularDistModules 4 }
|
|
|
|
isxModularDistModuleBreakerEntry OBJECT-TYPE
|
|
SYNTAX IsxModularDistModuleBreakerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information about a specific distribution modules and circuit breakers."
|
|
INDEX { isxModularDistModuleBreakerModIndex, isxModularDistModuleBreakerPhaseIndex}
|
|
::= { isxModularDistModuleBreakerTable 1 }
|
|
|
|
IsxModularDistModuleBreakerEntry ::=
|
|
SEQUENCE {
|
|
isxModularDistModuleBreakerModIndex INTEGER,
|
|
isxModularDistModuleBreakerPhaseIndex INTEGER,
|
|
isxModularDistModuleBreakerAlarmStatus INTEGER,
|
|
isxModularDistModuleBreakerRating INTEGER,
|
|
isxModularDistModuleBreakerPhysicalGroup INTEGER,
|
|
isxModularDistModuleBreakerCableNum INTEGER,
|
|
isxModularDistModuleBreakerPosition INTEGER,
|
|
isxModularDistModuleBreakerPositionAlarms INTEGER,
|
|
isxModularDistModuleBreakerCurrent INTEGER,
|
|
isxModularDistModuleBreakerPercent INTEGER,
|
|
isxModularDistModuleBreakerPower INTEGER
|
|
}
|
|
|
|
isxModularDistModuleBreakerModIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The distribution module number."
|
|
::= { isxModularDistModuleBreakerEntry 1 }
|
|
|
|
isxModularDistModuleBreakerPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phaseL1(1),
|
|
phaseL2(2),
|
|
phaseL3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to an individual breaker in the distribution module. The index also corresponds
|
|
to the system phase to which the breaker is attached."
|
|
::= { isxModularDistModuleBreakerEntry 2 }
|
|
|
|
isxModularDistModuleBreakerAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a bit map representing the active alarms for this breaker:
|
|
|
|
b0 - Minimum current threshold exceeded (critical)
|
|
b1 - Low current threshold exceeded (warning)
|
|
b2 - High current threshold exceeded (warning)
|
|
b3 - Maximum current threshold exceeded (critical)
|
|
b4 - Breaker is open (critical)
|
|
|
|
If a bit is set, the corresponding alarm is active."
|
|
::= { isxModularDistModuleBreakerEntry 3 }
|
|
|
|
isxModularDistModuleBreakerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current rating of the breaker."
|
|
::= { isxModularDistModuleBreakerEntry 4 }
|
|
|
|
isxModularDistModuleBreakerPhysicalGroup OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numeric value used to indicate that a breaker is a part of a multi-pole breaker.
|
|
Breakers within a distribution module, with equivalent physical group numbers,
|
|
may have their handles physically tied together.
|
|
A value of 1 indicates breakers that are physically tied together as part of a
|
|
multi-pole breaker.
|
|
A value of 0 indicates a single-handle breaker that is not physically tied to
|
|
another breaker."
|
|
::= { isxModularDistModuleBreakerEntry 5 }
|
|
|
|
isxModularDistModuleBreakerCableNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numeric value used to indicate the distribution cable to which
|
|
this breaker is connected. These distribution cables are described
|
|
in the table isxModularDistModuleOutputTable,
|
|
and indexed by the OID isxModularDistModuleOutputCordIndex."
|
|
::= { isxModularDistModuleBreakerEntry 6 }
|
|
|
|
isxModularDistModuleBreakerPosition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical status of this breaker pole, either closed or open (including tripped)."
|
|
::= { isxModularDistModuleBreakerEntry 7 }
|
|
|
|
isxModularDistModuleBreakerPositionAlarms OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable breaker position alarms for this circuit breaker."
|
|
::= { isxModularDistModuleBreakerEntry 8 }
|
|
|
|
isxModularDistModuleBreakerCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current flowing though this breaker. Measured in tenths of amps."
|
|
::= { isxModularDistModuleBreakerEntry 9 }
|
|
|
|
isxModularDistModuleBreakerPercent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The loading on this breaker as a percentage of the breaker's current rating.
|
|
Expressed in tenths of percent."
|
|
::= { isxModularDistModuleBreakerEntry 10 }
|
|
|
|
isxModularDistModuleBreakerPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power being supplied through this breaker. Measured in tenths of kW."
|
|
::= { isxModularDistModuleBreakerEntry 11 }
|
|
|
|
isxModularDistModuleOutputsTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the isxModularDistModuleOutputTable."
|
|
::= { isxModularDistModules 5 }
|
|
|
|
isxModularDistModuleOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IsxModularDistModuleOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting and setting information related to the
|
|
load equipment being fed by the distribution modules in the ISX
|
|
Modular Distribution System."
|
|
::= { isxModularDistModules 6 }
|
|
|
|
isxModularDistModuleOutputEntry OBJECT-TYPE
|
|
SYNTAX IsxModularDistModuleOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information about a specific distribution module
|
|
and its output distribution cables."
|
|
INDEX { isxModularDistModuleOutputModIndex, isxModularDistModuleOutputCordIndex }
|
|
::= { isxModularDistModuleOutputTable 1 }
|
|
|
|
IsxModularDistModuleOutputEntry ::=
|
|
SEQUENCE {
|
|
isxModularDistModuleOutputModIndex INTEGER,
|
|
isxModularDistModuleOutputNumCables INTEGER,
|
|
isxModularDistModuleOutputCordIndex INTEGER,
|
|
isxModularDistModuleOutputName DisplayString,
|
|
isxModularDistModuleOutputLocation DisplayString,
|
|
isxModularDistModuleOutputStatus INTEGER,
|
|
isxModularDistModuleOutputAlarmGeneration INTEGER,
|
|
isxModularDistModuleOutputBreakerMap INTEGER,
|
|
isxModularDistModuleOutputThresholdMin INTEGER,
|
|
isxModularDistModuleOutputThresholdLow INTEGER,
|
|
isxModularDistModuleOutputThresholdHigh INTEGER,
|
|
isxModularDistModuleOutputThresholdMax INTEGER,
|
|
isxModularDistModuleOutputAlarmMinEnable INTEGER,
|
|
isxModularDistModuleOutputAlarmLowEnable INTEGER,
|
|
isxModularDistModuleOutputAlarmHighEnable INTEGER,
|
|
isxModularDistModuleOutputAlarmMaxEnable INTEGER,
|
|
isxModularDistModuleOutputCableLength INTEGER,
|
|
isxModularDistModuleOutputConnectorType DisplayString,
|
|
isxModularDistModuleOutputAvailableVoltages INTEGER,
|
|
isxModularDistModuleOutputTotalPower INTEGER,
|
|
isxModularDistModuleOutputKwhUsage INTEGER,
|
|
isxModularDistModuleOutputKwhReset INTEGER,
|
|
isxModularDistModuleOutputKwhResetDate DisplayString
|
|
}
|
|
|
|
isxModularDistModuleOutputModIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the distribution module supplying power to the load equipment."
|
|
::= { isxModularDistModuleOutputEntry 1 }
|
|
|
|
isxModularDistModuleOutputNumCables OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of distribution cables provided by this module."
|
|
::= { isxModularDistModuleOutputEntry 2 }
|
|
|
|
isxModularDistModuleOutputCordIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of an individual distribution cable supplied by this module."
|
|
::= { isxModularDistModuleOutputEntry 3 }
|
|
|
|
isxModularDistModuleOutputName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string describing the load equipment being supplied by this distribution cable."
|
|
::= { isxModularDistModuleOutputEntry 4 }
|
|
|
|
isxModularDistModuleOutputLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string describing the location of equipment being supplied by distribution cable."
|
|
::= { isxModularDistModuleOutputEntry 5 }
|
|
|
|
isxModularDistModuleOutputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
warning (2),
|
|
critical (3),
|
|
notPresent (4),
|
|
unknown (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This reflects the worse case severity for alarms associated with this distribution cable.
|
|
A value of notPresent indicates that the cable does not exist for this module.
|
|
A value of unknown indicates that the there is no communication with the
|
|
metering segment for this distribution cable's module."
|
|
::= { isxModularDistModuleOutputEntry 6 }
|
|
|
|
isxModularDistModuleOutputAlarmGeneration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable all alarm generation related to this distribution cable."
|
|
::= { isxModularDistModuleOutputEntry 7 }
|
|
|
|
isxModularDistModuleOutputBreakerMap OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a bit map representing the breaker poles within the
|
|
module that are associated with this distribution cable.
|
|
The following 3 bits are used to indicate the indices of
|
|
the breakers feeding the cable:
|
|
|
|
b0 - Module breaker L1
|
|
b1 - Module breaker L2
|
|
b2 - Module breaker L3
|
|
|
|
If a bit is set, the breaker is used to feed this distribution cable.
|
|
These breakers are described in the table isxModularDistModuleBreakerTable,
|
|
and indexed by the OID isxModularDistModuleBreakerPhaseIndex."
|
|
::= { isxModularDistModuleOutputEntry 8 }
|
|
|
|
isxModularDistModuleOutputThresholdMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the current drops below this value a critical alarm will exist."
|
|
::= { isxModularDistModuleOutputEntry 9 }
|
|
|
|
isxModularDistModuleOutputThresholdLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the current drops below this value a warning alarm will exist."
|
|
::= { isxModularDistModuleOutputEntry 10 }
|
|
|
|
isxModularDistModuleOutputThresholdHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the current exceeds this value a warning alarm will exist."
|
|
::= { isxModularDistModuleOutputEntry 11 }
|
|
|
|
isxModularDistModuleOutputThresholdMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the current exceeds this value a critical alarm will exist."
|
|
::= { isxModularDistModuleOutputEntry 12 }
|
|
|
|
isxModularDistModuleOutputAlarmMinEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable minimum current alarm generation for this distribution cable."
|
|
::= { isxModularDistModuleOutputEntry 13 }
|
|
|
|
isxModularDistModuleOutputAlarmLowEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable low current alarm generation for this distribution cable."
|
|
::= { isxModularDistModuleOutputEntry 14 }
|
|
|
|
isxModularDistModuleOutputAlarmHighEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable high current alarm generation for this distribution cable."
|
|
::= { isxModularDistModuleOutputEntry 15 }
|
|
|
|
isxModularDistModuleOutputAlarmMaxEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable maximum current alarm generation for this distribution cable."
|
|
::= { isxModularDistModuleOutputEntry 16 }
|
|
|
|
isxModularDistModuleOutputCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length of this distribution cable. Specified in tenths of meters."
|
|
::= { isxModularDistModuleOutputEntry 17 }
|
|
|
|
isxModularDistModuleOutputConnectorType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string describing the connector on the end of this distribution cable."
|
|
::= { isxModularDistModuleOutputEntry 18 }
|
|
|
|
isxModularDistModuleOutputAvailableVoltages OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a bit map representing the voltages that are available at the connector.
|
|
6 bits are used to indicate the following:
|
|
|
|
b0 - L1
|
|
b1 - L2
|
|
b2 - L3
|
|
b3 - L1-2
|
|
b4 - L2-3
|
|
b5 - L3-1"
|
|
::= { isxModularDistModuleOutputEntry 19 }
|
|
|
|
isxModularDistModuleOutputTotalPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total power being consumed by the load equipment supplied by this distribution cable.
|
|
Measured in tenths of kW."
|
|
::= { isxModularDistModuleOutputEntry 20 }
|
|
|
|
isxModularDistModuleOutputKwhUsage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total energy consumed by the load equipment fed by this distribution cable.
|
|
This is the total since the date specified in the isxModularDistModuleOutputKwhResetDate
|
|
OID, and may be cleared using the isxModularDistModuleOutputKwhReset OID.
|
|
Measured in tenths of kWh."
|
|
::= { isxModularDistModuleOutputEntry 21 }
|
|
|
|
isxModularDistModuleOutputKwhReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing yes to this OID will reset the total kWh usage shown
|
|
in the isxModularDistModuleOutputKwhUsage OID."
|
|
::= { isxModularDistModuleOutputEntry 22 }
|
|
|
|
isxModularDistModuleOutputKwhResetDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000."
|
|
::= { isxModularDistModuleOutputEntry 23 }
|
|
|
|
-- Distribution Subfeeds
|
|
|
|
isxModularDistSubFeedInfoTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the isxModularDistSubFeedInfoTable."
|
|
::= { isxModularDistSubFeeds 1 }
|
|
|
|
isxModularDistSubFeedInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IsxModularDistSubFeedInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting information about distribution subfeed breakers."
|
|
::= { isxModularDistSubFeeds 2 }
|
|
|
|
isxModularDistSubFeedInfoEntry OBJECT-TYPE
|
|
SYNTAX IsxModularDistSubFeedInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information about a specific distribution subfeed."
|
|
INDEX { isxModularDistSubFeedInfoSubIndex }
|
|
::= { isxModularDistSubFeedInfoTable 1 }
|
|
|
|
IsxModularDistSubFeedInfoEntry ::=
|
|
SEQUENCE {
|
|
isxModularDistSubFeedInfoSubIndex INTEGER,
|
|
isxModularDistSubFeedInfoName DisplayString,
|
|
isxModularDistSubFeedInfoLocation DisplayString,
|
|
isxModularDistSubFeedInfoBreakerRating INTEGER,
|
|
isxModularDistSubFeedInfoBreakerPosition INTEGER,
|
|
isxModularDistSubFeedInfoAlarmStatus INTEGER,
|
|
isxModularDistSubFeedInfoAlarmGeneration INTEGER,
|
|
isxModularDistSubFeedInfoThresholdMin INTEGER,
|
|
isxModularDistSubFeedInfoThresholdLow INTEGER,
|
|
isxModularDistSubFeedInfoThresholdHigh INTEGER,
|
|
isxModularDistSubFeedInfoThresholdMax INTEGER,
|
|
isxModularDistSubFeedInfoAlarmMinEnable INTEGER,
|
|
isxModularDistSubFeedInfoAlarmLowEnable INTEGER,
|
|
isxModularDistSubFeedInfoAlarmHighEnable INTEGER,
|
|
isxModularDistSubFeedInfoAlarmMaxEnable INTEGER,
|
|
isxModularDistSubFeedInfoBreakerAlarmEnable INTEGER,
|
|
isxModularDistSubFeedInfoTotalPower INTEGER,
|
|
isxModularDistSubFeedInfoKwhUsage INTEGER,
|
|
isxModularDistSubFeedInfoKwhReset INTEGER,
|
|
isxModularDistSubFeedInfoKwhResetDate DisplayString
|
|
}
|
|
|
|
isxModularDistSubFeedInfoSubIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of an individual subfeed."
|
|
::= { isxModularDistSubFeedInfoEntry 1 }
|
|
|
|
isxModularDistSubFeedInfoName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string describing the load equipment being supplied by this subfeed."
|
|
::= { isxModularDistSubFeedInfoEntry 2 }
|
|
|
|
isxModularDistSubFeedInfoLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string describing the location of the equipment being supplied by this subfeed."
|
|
::= { isxModularDistSubFeedInfoEntry 3 }
|
|
|
|
isxModularDistSubFeedInfoBreakerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current rating of this subfeed breaker."
|
|
::= { isxModularDistSubFeedInfoEntry 4 }
|
|
|
|
isxModularDistSubFeedInfoBreakerPosition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The operational status of this breaker, either closed or open (including tripped)."
|
|
::= { isxModularDistSubFeedInfoEntry 5 }
|
|
|
|
isxModularDistSubFeedInfoAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
warning (2),
|
|
critical (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The worst case alarm status for this subfeed."
|
|
::= { isxModularDistSubFeedInfoEntry 6 }
|
|
|
|
isxModularDistSubFeedInfoAlarmGeneration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable all alarm generation related to this subfeed."
|
|
::= { isxModularDistSubFeedInfoEntry 7 }
|
|
|
|
isxModularDistSubFeedInfoThresholdMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the current drops below this value a critical alarm will exist."
|
|
::= { isxModularDistSubFeedInfoEntry 8 }
|
|
|
|
isxModularDistSubFeedInfoThresholdLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the current drops below this value a warning alarm will exist."
|
|
::= { isxModularDistSubFeedInfoEntry 9 }
|
|
|
|
isxModularDistSubFeedInfoThresholdHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the current exceeds this value a warning alarm will exist."
|
|
::= { isxModularDistSubFeedInfoEntry 10 }
|
|
|
|
isxModularDistSubFeedInfoThresholdMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the current exceeds this value a critical alarm will exist."
|
|
::= { isxModularDistSubFeedInfoEntry 11 }
|
|
|
|
isxModularDistSubFeedInfoAlarmMinEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable minimum current alarm generation for this subfeed."
|
|
::= { isxModularDistSubFeedInfoEntry 12 }
|
|
|
|
isxModularDistSubFeedInfoAlarmLowEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable low current alarm generation for this subfeed."
|
|
::= { isxModularDistSubFeedInfoEntry 13 }
|
|
|
|
isxModularDistSubFeedInfoAlarmHighEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable high current alarm generation for this subfeed."
|
|
::= { isxModularDistSubFeedInfoEntry 14 }
|
|
|
|
isxModularDistSubFeedInfoAlarmMaxEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable maximum current alarm generation for this subfeed."
|
|
::= { isxModularDistSubFeedInfoEntry 15 }
|
|
|
|
isxModularDistSubFeedInfoBreakerAlarmEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable breaker position alarms for this subfeed."
|
|
::= { isxModularDistSubFeedInfoEntry 16 }
|
|
|
|
isxModularDistSubFeedInfoTotalPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total power being supplied by this subfeed. Measured in tenths of kW."
|
|
::= { isxModularDistSubFeedInfoEntry 17 }
|
|
|
|
isxModularDistSubFeedInfoKwhUsage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total energy consumed by the load equipment fed by this subfeed.
|
|
This is the total since the date specified in the isxModularDistSubFeedInfoKwhResetDate
|
|
OID, and may be cleared using the isxModularDistSubFeedInfoKwhReset OID.
|
|
Measured in tenths of kWh."
|
|
::= { isxModularDistSubFeedInfoEntry 18 }
|
|
|
|
isxModularDistSubFeedInfoKwhReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing yes to this OID will reset the total kWh usage shown
|
|
in the isxModularDistSubFeedInfoKwhUsage OID."
|
|
::= { isxModularDistSubFeedInfoEntry 19 }
|
|
|
|
isxModularDistSubFeedInfoKwhResetDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000."
|
|
::= { isxModularDistSubFeedInfoEntry 20 }
|
|
|
|
isxModularDistSubFeedLoadingTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the isxModularDistSubFeedLoadingTable."
|
|
::= { isxModularDistSubFeeds 3 }
|
|
|
|
isxModularDistSubFeedLoadingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IsxModularDistSubFeedLoadingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting subfeed phase loading information."
|
|
::= { isxModularDistSubFeeds 4 }
|
|
|
|
isxModularDistSubFeedLoadingEntry OBJECT-TYPE
|
|
SYNTAX IsxModularDistSubFeedLoadingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing data for an individual subfeed."
|
|
INDEX { isxModularDistSubFeedLoadingSubIndex, isxModularDistSubFeedLoadingPhaseIndex }
|
|
::= { isxModularDistSubFeedLoadingTable 1 }
|
|
|
|
IsxModularDistSubFeedLoadingEntry ::= SEQUENCE {
|
|
isxModularDistSubFeedLoadingSubIndex INTEGER,
|
|
isxModularDistSubFeedLoadingPhaseIndex INTEGER,
|
|
isxModularDistSubFeedLoadingAlarmStatus INTEGER,
|
|
isxModularDistSubFeedLoadingCurrent INTEGER,
|
|
isxModularDistSubFeedLoadingPercent INTEGER,
|
|
isxModularDistSubFeedLoadingPower INTEGER
|
|
}
|
|
|
|
isxModularDistSubFeedLoadingSubIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of an individual subfeed."
|
|
::= { isxModularDistSubFeedLoadingEntry 1 }
|
|
|
|
isxModularDistSubFeedLoadingPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each input phase entry in the table."
|
|
::= { isxModularDistSubFeedLoadingEntry 2 }
|
|
|
|
isxModularDistSubFeedLoadingAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a bit map representing the active alarms for this subfeed:
|
|
|
|
b0 - Minimum current threshold exceeded (critical)
|
|
b1 - Low current threshold exceeded (warning)
|
|
b2 - High current threshold exceeded (warning)
|
|
b3 - Maximum current threshold exceeded (critical)
|
|
b4 - Breaker is open (critical)
|
|
|
|
If a bit is set, the corresponding alarm is active."
|
|
::= { isxModularDistSubFeedLoadingEntry 3 }
|
|
|
|
isxModularDistSubFeedLoadingCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current flowing though this subfeed phase. Measured in tenths of amps."
|
|
::= { isxModularDistSubFeedLoadingEntry 4 }
|
|
|
|
isxModularDistSubFeedLoadingPercent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The loading on this subfeed phase as a percentage of the subfeed's current rating.
|
|
Expressed in tenths of percent."
|
|
::= { isxModularDistSubFeedLoadingEntry 5 }
|
|
|
|
isxModularDistSubFeedLoadingPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power being supplied by this subfeed phase. Measured in tenths of kW."
|
|
::= { isxModularDistSubFeedLoadingEntry 6 }
|
|
|
|
-- Distribution System Output Voltage
|
|
|
|
isxModularDistSysOutputVoltageNominalLineToNeutral OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal line-to-neutral voltage available at the distribution panel."
|
|
::= { isxModularDistSysVoltage 1 }
|
|
|
|
isxModularDistSysOutputVoltageNominalLineToLine OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal line-to-line voltage available at the distribution panel."
|
|
::= { isxModularDistSysVoltage 2 }
|
|
|
|
isxModularDistSysOutputNominalFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal system output frequency. Measured in tenths of Hertz."
|
|
::= { isxModularDistSysVoltage 3 }
|
|
|
|
isxModularDistSysOutputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system output frequency in tenths of Hertz.
|
|
-1 if not available."
|
|
::= { isxModularDistSysVoltage 4 }
|
|
|
|
isxModularDistSysOutputVoltageMonitoring OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not output voltage alarm generation is present."
|
|
::= { isxModularDistSysVoltage 5 }
|
|
|
|
isxModularDistSysOutputVoltageThresholdMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the line-to-neutral voltage of any phase drops below this value a critical alarm will exist.
|
|
Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral.
|
|
This value is returned as a positive number which represents a negative percentage.
|
|
A value of -1 indicates that the threshold is not available in the device."
|
|
::= { isxModularDistSysVoltage 6 }
|
|
|
|
isxModularDistSysOutputVoltageThresholdLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the line-to-neutral voltage of any phase drops below this value a warning alarm will exist.
|
|
Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral.
|
|
This value is returned as a positive number which represents a negative percentage.
|
|
A value of -1 indicates that the threshold is not available in the device."
|
|
::= { isxModularDistSysVoltage 7 }
|
|
|
|
isxModularDistSysOutputVoltageThresholdHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the line-to-neutral voltage of any phase exceeds this value a warning alarm will exist.
|
|
Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral.
|
|
A value of -1 indicates that the threshold is not available in the device."
|
|
::= { isxModularDistSysVoltage 8 }
|
|
|
|
isxModularDistSysOutputVoltageThresholdMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the line-to-neutral voltage of any phase exceeds this value a critical alarm will exist.
|
|
Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral.
|
|
A value of -1 indicates that the threshold is not available in the device."
|
|
::= { isxModularDistSysVoltage 9 }
|
|
|
|
isxModularDistSysOutputVoltageAlarmMinEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable minimum voltage alarm generation for the distribution panel."
|
|
::= { isxModularDistSysVoltage 10 }
|
|
|
|
isxModularDistSysOutputVoltageAlarmLowEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable low voltage alarm generation for the distribution panel."
|
|
::= { isxModularDistSysVoltage 11 }
|
|
|
|
isxModularDistSysOutputVoltageAlarmHighEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable high voltage alarm generation for the distribution panel."
|
|
::= { isxModularDistSysVoltage 12 }
|
|
|
|
isxModularDistSysOutputVoltageAlarmMaxEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable maximum voltage alarm generation for the distribution panel."
|
|
::= { isxModularDistSysVoltage 13 }
|
|
|
|
isxModularDistSysOutputVoltageFrequencyTolerance OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
freqToleranceOff (1),
|
|
freqTolerancePointTwo (2),
|
|
freqTolerancePointFive (3),
|
|
freqToleranceOne (4),
|
|
freqToleranceOnePointFive (5),
|
|
freqToleranceTwo (6),
|
|
freqToleranceThree (7),
|
|
freqToleranceFour (8),
|
|
freqToleranceFive (9),
|
|
freqToleranceNine (10),
|
|
freqToleranceNotAvailable (11)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The circuit panel output frequency tolerance in Hertz.
|
|
When the system output frequency deviates from the nominal by more than this range,
|
|
a critical alarm will be generated."
|
|
::= { isxModularDistSysVoltage 14 }
|
|
|
|
isxModularDistSysVoltageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IsxModularDistSysVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the system output voltage information."
|
|
::= { isxModularDistSysVoltage 15 }
|
|
|
|
isxModularDistSysVoltageEntry OBJECT-TYPE
|
|
SYNTAX IsxModularDistSysVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing data for an individual system output phase."
|
|
INDEX { isxModularDistSysVoltagePhaseIndex }
|
|
::= { isxModularDistSysVoltageTable 1 }
|
|
|
|
IsxModularDistSysVoltageEntry ::=
|
|
SEQUENCE {
|
|
isxModularDistSysVoltagePhaseIndex INTEGER,
|
|
isxModularDistSysVoltageAlarmStatus INTEGER,
|
|
isxModularDistSysVoltageLtoN INTEGER,
|
|
isxModularDistSysVoltageLtoL INTEGER
|
|
}
|
|
|
|
isxModularDistSysVoltagePhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each phase entry in the table."
|
|
::= { isxModularDistSysVoltageEntry 1 }
|
|
|
|
isxModularDistSysVoltageAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a bit map representing the active alarms for this output phase:
|
|
|
|
b0 - Minimum voltage threshold exceeded (critical)
|
|
b1 - Low voltage threshold exceeded (warning)
|
|
b2 - High voltage threshold exceeded (warning)
|
|
b3 - Maximum voltage threshold exceeded (critical)
|
|
|
|
If a bit is set, the corresponding alarm is active."
|
|
::= { isxModularDistSysVoltageEntry 2 }
|
|
|
|
isxModularDistSysVoltageLtoN OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-neutral system output voltage available at the distribution panel.
|
|
Measured in tenths of Volts."
|
|
::= { isxModularDistSysVoltageEntry 3 }
|
|
|
|
isxModularDistSysVoltageLtoL OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Line-to-line system output voltage available at the distribution panel.
|
|
Measured in tenths of Volts."
|
|
::= { isxModularDistSysVoltageEntry 4 }
|
|
|
|
|
|
-- Distribution System Total Output Current
|
|
|
|
isxModularDistSysCurrentRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The 100 percent current rating of the distribution panel."
|
|
::= { isxModularDistSysCurrent 1 }
|
|
|
|
isxModularDistSysCurrentMonitoring OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not total output current measurements and alarm generation are present."
|
|
::= { isxModularDistSysCurrent 2 }
|
|
|
|
isxModularDistSysCurrentThresholdMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When total system current in any phase drops below this value a critical alarm will exist.
|
|
Specified as a percent of the panel rating, isxModularDistSysCurrentRating.
|
|
A value of -1 indicates that the threshold is not available in the device."
|
|
::= { isxModularDistSysCurrent 3 }
|
|
|
|
isxModularDistSysCurrentThresholdLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When total system current in any phase drops below this value a warning alarm will exist.
|
|
Specified as a percent of the panel rating, isxModularDistSysCurrentRating.
|
|
A value of -1 indicates that the threshold is not available in the device."
|
|
::= { isxModularDistSysCurrent 4 }
|
|
|
|
isxModularDistSysCurrentThresholdHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When total system current in any phase exceeds this value a warning alarm will exist.
|
|
Specified as a percent of the panel rating, isxModularDistSysCurrentRating.
|
|
A value of -1 indicates that the threshold is not available in the device."
|
|
::= { isxModularDistSysCurrent 5 }
|
|
|
|
isxModularDistSysCurrentThresholdMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When total system current in any phase exceeds this value a critical alarm will exist.
|
|
Specified as a percent of the panel rating, isxModularDistSysCurrentRating.
|
|
A value of -1 indicates that the threshold is not available in the device."
|
|
::= { isxModularDistSysCurrent 6 }
|
|
|
|
isxModularDistSysCurrentAlarmMinEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable minimum total output current alarm generation."
|
|
::= { isxModularDistSysCurrent 7 }
|
|
|
|
isxModularDistSysCurrentAlarmLowEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable low total output current alarm generation."
|
|
::= { isxModularDistSysCurrent 8 }
|
|
|
|
isxModularDistSysCurrentAlarmHighEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable high total output current alarm generation."
|
|
::= { isxModularDistSysCurrent 9 }
|
|
|
|
isxModularDistSysCurrentAlarmMaxEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable maximum total output current alarm generation."
|
|
::= { isxModularDistSysCurrent 10 }
|
|
|
|
isxModularDistSysCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IsxModularDistSysCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the total system phase current information."
|
|
::= { isxModularDistSysCurrent 11 }
|
|
|
|
isxModularDistSysCurrentEntry OBJECT-TYPE
|
|
SYNTAX IsxModularDistSysCurrentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing data for an individual system output phase."
|
|
INDEX { isxModularDistSysCurrentPhaseIndex }
|
|
::= { isxModularDistSysCurrentTable 1 }
|
|
|
|
IsxModularDistSysCurrentEntry ::=
|
|
SEQUENCE {
|
|
isxModularDistSysCurrentPhaseIndex INTEGER,
|
|
isxModularDistSysCurrentAlarmStatus INTEGER,
|
|
isxModularDistSysCurrentAmps INTEGER,
|
|
isxModularDistSysCurrentPercent INTEGER
|
|
}
|
|
|
|
isxModularDistSysCurrentPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each phase entry in the table."
|
|
::= { isxModularDistSysCurrentEntry 1 }
|
|
|
|
isxModularDistSysCurrentAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a bit map representing the active alarms for this output phase:
|
|
|
|
b0 - Minimum current threshold exceeded (critical)
|
|
b1 - Low current threshold exceeded (warning)
|
|
b2 - High current threshold exceeded (warning)
|
|
b3 - Maximum current threshold exceeded (critical)
|
|
|
|
If a bit is set, the corresponding alarm is active."
|
|
::= { isxModularDistSysCurrentEntry 2 }
|
|
|
|
isxModularDistSysCurrentAmps OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current flowing though this system output phase. Measured in tenths of amps."
|
|
::= { isxModularDistSysCurrentEntry 3 }
|
|
|
|
isxModularDistSysCurrentPercent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The loading on this system output phase as a percentage of the panel current rating.
|
|
Expressed in tenths of percent."
|
|
::= { isxModularDistSysCurrentEntry 4 }
|
|
|
|
-- Distribution System Total Output Power
|
|
|
|
isxModularDistSysPowerTotal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total system power being supplied. Measured in tenths of kW."
|
|
::= { isxModularDistSysPower 1 }
|
|
|
|
isxModularDistSysPowerKwhUsage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total system energy consumed by the load equipment.
|
|
This is the total since the date specified in the isxModularDistSysOutputKwhResetDate
|
|
OID, and may be cleared using the isxModularDistSysOutputKwhReset OID.
|
|
Measured in tenths of kWh."
|
|
::= { isxModularDistSysPower 2 }
|
|
|
|
isxModularDistSysPowerKwhReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing yes to this OID will reset the total kWh usage shown
|
|
in the isxModularDistSysPowerKwhUsage OID."
|
|
::= { isxModularDistSysPower 3 }
|
|
|
|
isxModularDistSysPowerKwhResetDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000."
|
|
::= { isxModularDistSysPower 4 }
|
|
|
|
isxModularDistSysPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IsxModularDistSysPowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the total system phase power loading information."
|
|
::= { isxModularDistSysPower 5 }
|
|
|
|
isxModularDistSysPowerEntry OBJECT-TYPE
|
|
SYNTAX IsxModularDistSysPowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing data for an individual system output phase."
|
|
INDEX { isxModularDistSysPowerPhaseIndex }
|
|
::= { isxModularDistSysPowerTable 1 }
|
|
|
|
IsxModularDistSysPowerEntry ::=
|
|
SEQUENCE {
|
|
isxModularDistSysPowerPhaseIndex INTEGER,
|
|
isxModularDistSysPowerKw INTEGER,
|
|
isxModularDistSysPowerKwhPhaseUsage INTEGER
|
|
}
|
|
|
|
isxModularDistSysPowerPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
phase1(1),
|
|
phase2(2),
|
|
phase3(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of each phase entry in the table."
|
|
::= { isxModularDistSysPowerEntry 1 }
|
|
|
|
isxModularDistSysPowerKw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power being supplied by this system output phase. Measured in tenths of kW."
|
|
::= { isxModularDistSysPowerEntry 2 }
|
|
|
|
isxModularDistSysPowerKwhPhaseUsage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The energy consumed by the load equipment on this system output phase.
|
|
This is the total since the date specified in the isxModularDistSysPowerKwhResetDate
|
|
OID, and may be cleared using the isxModularDistSysPowerKwhReset OID.
|
|
Measured in tenths of kWh."
|
|
::= { isxModularDistSysPowerEntry 3 }
|
|
|
|
-- the isxModularPduIdent group
|
|
|
|
isxModularPduIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the model number of the PDU.
|
|
This value is set at the factory."
|
|
::= { isxModularPduIdent 1 }
|
|
|
|
isxModularPduIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the serial number of the PDU.
|
|
This value is set at the factory."
|
|
::= { isxModularPduIdent 2 }
|
|
|
|
isxModularPduIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the PDU was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory."
|
|
::= { isxModularPduIdent 3 }
|
|
|
|
isxModularPduIdentMonitorCardSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A character string identifying the serial number of the PDU monitor card.
|
|
This value is set at the factory."
|
|
::= { isxModularPduIdent 4 }
|
|
|
|
isxModularPduIdentMonitorCardHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the PDU monitor card.
|
|
This value is set at the factory."
|
|
::= { isxModularPduIdent 5 }
|
|
|
|
isxModularPduIdentMonitorCardFirmwareAppRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ID string identifying the application firmware revision of the
|
|
PDU monitor card."
|
|
::= { isxModularPduIdent 6 }
|
|
|
|
isxModularPduIdentMonitorCardFirmwareAppOSRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An ID string identifying the application operating system firmware revision of the
|
|
PDU monitor card."
|
|
::= { isxModularPduIdent 7 }
|
|
|
|
-- the isxModularPduDevice group
|
|
|
|
isxModularPduDeviceTransformerPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
isoXfmrPresent (2),
|
|
autoXfmrPresent (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the type of transformer present in this PDU."
|
|
::= { isxModularPduDevice 1 }
|
|
|
|
isxModularPduDeviceServiceType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
threeWire (1),
|
|
fourWire (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye)."
|
|
::= { isxModularPduDevice 2 }
|
|
|
|
isxModularPduDeviceFansPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
present (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not cooling fans are installed in the PDU."
|
|
::= { isxModularPduDevice 3 }
|
|
|
|
isxModularPduDeviceNominalMainInputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal main input voltage to the system. Measured in Volts,
|
|
line-to-line for a 3-wire (delta) service or line-to-neutral for a
|
|
4-wire (wye) service. -1 if main input voltage is not being measured."
|
|
::= { isxModularPduDevice 4 }
|
|
|
|
isxModularPduAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
warning (2),
|
|
critical (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The overall status (worst case) of this PDU."
|
|
::= { isxModularPduStatus 1 }
|
|
|
|
isxModularPduTransformerTempStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
overtemp (2),
|
|
noTransformerPresent (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if the PDU isolation transformer is over temperature."
|
|
::= { isxModularPduStatus 2 }
|
|
|
|
isxModularPduFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
failed (2),
|
|
noCoolingFansPresent (3),
|
|
unknown (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if one or more of the PDU's cooling fans have failed."
|
|
::= { isxModularPduStatus 3 }
|
|
|
|
|
|
-- Universal Input / Output (uio)
|
|
|
|
-- uio Sensor Status Table
|
|
|
|
uioSensorStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the uioSensorStatusTable."
|
|
::= { uioSensor 1 }
|
|
|
|
uioSensorStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UIOSensorStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting sensor status information."
|
|
::= { uioSensor 2 }
|
|
|
|
uioSensorStatusEntry OBJECT-TYPE
|
|
SYNTAX UIOSensorStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit from which to get data."
|
|
INDEX { uioSensorStatusPortID, uioSensorStatusSensorID }
|
|
::= { uioSensorStatusTable 1 }
|
|
|
|
UIOSensorStatusEntry ::=
|
|
SEQUENCE {
|
|
uioSensorStatusPortID INTEGER,
|
|
uioSensorStatusSensorID INTEGER,
|
|
uioSensorStatusSensorName DisplayString,
|
|
uioSensorStatusSensorLocation DisplayString,
|
|
uioSensorStatusTemperatureDegF INTEGER,
|
|
uioSensorStatusTemperatureDegC INTEGER,
|
|
uioSensorStatusHumidity INTEGER,
|
|
uioSensorStatusViolationStatus INTEGER,
|
|
uioSensorStatusAlarmStatus INTEGER,
|
|
uioSensorStatusCommStatus INTEGER
|
|
}
|
|
|
|
uioSensorStatusPortID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ID of the Universal IO port to which the sensor is attached."
|
|
::= { uioSensorStatusEntry 1 }
|
|
|
|
uioSensorStatusSensorID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ID of the sensor."
|
|
::= { uioSensorStatusEntry 2 }
|
|
|
|
uioSensorStatusSensorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor name."
|
|
::= { uioSensorStatusEntry 3 }
|
|
|
|
uioSensorStatusSensorLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the sensor."
|
|
::= { uioSensorStatusEntry 4 }
|
|
|
|
uioSensorStatusTemperatureDegF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor's current temperature reading in tenths of degrees Fahrenheit."
|
|
::= { uioSensorStatusEntry 5 }
|
|
|
|
uioSensorStatusTemperatureDegC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor's current temperature reading in tenths of degrees Celsius."
|
|
::= { uioSensorStatusEntry 6 }
|
|
|
|
uioSensorStatusHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current humidity reading in tenths of percent from the sensor."
|
|
::= { uioSensorStatusEntry 7 }
|
|
|
|
uioSensorStatusViolationStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The violation status of the sensor. This integer should be interpreted
|
|
as a bit map, with each bit representing the presence or absence of
|
|
the specific alarm conditions listed below. The bit will be '1' if
|
|
the condition is present, and '0' if the condition is not present.
|
|
|
|
Bit Hex. Value Description
|
|
1 0x0001 Maximum temperature exceeded.
|
|
2 0x0002 High temperature exceeded.
|
|
3 0x0004 Low temperature exceeded.
|
|
4 0x0008 Minimum temperature exceeded.
|
|
5 0x0010 Short-term increasing temperature rate exceeded (Not used).
|
|
6 0x0020 Short-term decreasing temperature rate exceeded (Not used).
|
|
7 0x0040 Long-term increasing temperature rate exceeded (Not used).
|
|
8 0x0080 Long-term decreasing temperature rate exceeded (Not used).
|
|
9 0x0100 Maximum humidity exceeded.
|
|
10 0x0200 High humidity exceeded.
|
|
11 0x0400 Low humidity exceeded.
|
|
12 0x0800 Minimum humidity exceeded."
|
|
::= { uioSensorStatusEntry 8 }
|
|
|
|
uioSensorStatusAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uioNormal (1),
|
|
uioWarning (2),
|
|
uioCritical (3),
|
|
sensorStatusNotApplicable (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm status of the sensor."
|
|
::= { uioSensorStatusEntry 9 }
|
|
|
|
uioSensorStatusCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notInstalled (1),
|
|
commsOK (2),
|
|
commsLost (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The communications status of the sensor."
|
|
::= { uioSensorStatusEntry 10 }
|
|
|
|
|
|
-- uio Input Contact Status Table
|
|
|
|
uioInputContactStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the uioInputContactStatusTable."
|
|
::= { uioInputContact 1 }
|
|
|
|
uioInputContactStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UIOInputContactStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting input contact status information."
|
|
::= { uioInputContact 2 }
|
|
|
|
uioInputContactStatusEntry OBJECT-TYPE
|
|
SYNTAX UIOInputContactStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input contact from which to get data."
|
|
INDEX { uioInputContactStatusPortID, uioInputContactStatusContactID }
|
|
::= { uioInputContactStatusTable 1 }
|
|
|
|
UIOInputContactStatusEntry ::=
|
|
SEQUENCE {
|
|
uioInputContactStatusPortID INTEGER,
|
|
uioInputContactStatusContactID INTEGER,
|
|
uioInputContactStatusContactName DisplayString,
|
|
uioInputContactStatusContactLocation DisplayString,
|
|
uioInputContactStatusCurrentState INTEGER,
|
|
uioInputContactStatusAlarmStatus INTEGER,
|
|
uioInputContactStatusCommStatus INTEGER
|
|
}
|
|
|
|
uioInputContactStatusPortID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ID of the port to which the input contact is attached."
|
|
::= { uioInputContactStatusEntry 1 }
|
|
|
|
uioInputContactStatusContactID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ID of the input contact on the module."
|
|
::= { uioInputContactStatusEntry 2 }
|
|
|
|
uioInputContactStatusContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input contact name."
|
|
::= { uioInputContactStatusEntry 3 }
|
|
|
|
uioInputContactStatusContactLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the input contact."
|
|
::= { uioInputContactStatusEntry 4 }
|
|
|
|
uioInputContactStatusCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uioInputClosed (1),
|
|
uioInputOpen (2),
|
|
uioInputDisabled (3),
|
|
inputStateNotApplicable (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of the input contact. "
|
|
::= { uioInputContactStatusEntry 5 }
|
|
|
|
uioInputContactStatusAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uioNormal (1),
|
|
uioWarning (2),
|
|
uioCritical (3),
|
|
inputStatusNotApplicable (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm status of the input contact."
|
|
::= { uioInputContactStatusEntry 6 }
|
|
|
|
uioInputContactStatusCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notInstalled (1),
|
|
commsOK (2),
|
|
commsLost (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The communications status of the input contact."
|
|
::= { uioInputContactStatusEntry 7 }
|
|
|
|
|
|
-- uio Output Relay Status Table
|
|
|
|
uioOutputRelayStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of entries in the uioOutputRelayStatusTable."
|
|
::= { uioOutputRelay 1 }
|
|
|
|
uioOutputRelayStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UIOOutputRelayStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting output relay status information."
|
|
::= { uioOutputRelay 2 }
|
|
|
|
uioOutputRelayStatusEntry OBJECT-TYPE
|
|
SYNTAX UIOOutputRelayStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit from which to get data."
|
|
INDEX { uioOutputRelayStatusPortID, uioOutputRelayStatusRelayID }
|
|
::= { uioOutputRelayStatusTable 1 }
|
|
|
|
UIOOutputRelayStatusEntry ::=
|
|
SEQUENCE {
|
|
uioOutputRelayStatusPortID INTEGER,
|
|
uioOutputRelayStatusRelayID INTEGER,
|
|
uioOutputRelayStatusRelayName DisplayString,
|
|
uioOutputRelayStatusRelayLocation DisplayString,
|
|
uioOutputRelayStatusCurrentState INTEGER,
|
|
uioOutputRelayStatusAlarmStatus INTEGER,
|
|
uioOutputRelayStatusCommStatus INTEGER
|
|
}
|
|
|
|
uioOutputRelayStatusPortID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ID of the module to which the output relay is attached."
|
|
::= { uioOutputRelayStatusEntry 1 }
|
|
|
|
uioOutputRelayStatusRelayID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ID of the output relay on the module."
|
|
::= { uioOutputRelayStatusEntry 2 }
|
|
|
|
uioOutputRelayStatusRelayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output relay name."
|
|
::= { uioOutputRelayStatusEntry 3 }
|
|
|
|
uioOutputRelayStatusRelayLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the output relay."
|
|
::= { uioOutputRelayStatusEntry 4 }
|
|
|
|
uioOutputRelayStatusCurrentState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uioOutputClosed (1),
|
|
uioOutputOpen (2),
|
|
outputStateNotApplicable (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of the output relay."
|
|
::= { uioOutputRelayStatusEntry 5 }
|
|
|
|
uioOutputRelayStatusAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uioNormal (1),
|
|
uioWarning (2),
|
|
uioCritical (3),
|
|
inputStatusNotApplicable (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm status of the output relay."
|
|
::= { uioOutputRelayStatusEntry 6 }
|
|
|
|
uioOutputRelayStatusCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notInstalled (1),
|
|
commsOK (2),
|
|
commsLost (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The communications status of the output relay."
|
|
::= { uioOutputRelayStatusEntry 7 }
|
|
|
|
|
|
-- Traps
|
|
-- Annotations are provided for Novell's NMS product
|
|
--
|
|
-- Each trap has at least one variable (mtrapargsString) which always appears
|
|
-- as the last variable in the list. This variable contains either a static
|
|
-- or dynamically-constructed string which provides an enhanced description of
|
|
-- the trap's purpose and any pertinent information about the trap.
|
|
|
|
communicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communication to the UPS has been lost. Steps
|
|
to reestablish communication are in progress."
|
|
--#TYPE "APC UPS: Communication lost"
|
|
--#SUMMARY "Communication lost between the agent and the UPS."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 1
|
|
|
|
upsOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The UPS has sensed a load greater than 100 percent
|
|
of its rated capacity."
|
|
--#TYPE "APC UPS: Overload"
|
|
--#SUMMARY "The UPS has sensed a load greater than 100 percent of its rated capacity."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 2
|
|
|
|
upsDiagnosticsFailed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The UPS failed its internal diagnostic self-test."
|
|
--#TYPE "APC UPS: Failed self-test"
|
|
--#SUMMARY "The UPS has failed its internal self-test."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 3
|
|
|
|
upsDischarged TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The UPS batteries are discharged; if utility power fails
|
|
an immediate low battery condition will exist. Sufficient runtime
|
|
for necessary action cannot be guaranteed."
|
|
--#TYPE "APC UPS: batteries are discharged"
|
|
--#SUMMARY "The UPS batteries are discharged."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 4
|
|
|
|
upsOnBattery TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS has switched to battery backup power."
|
|
--#TYPE "APC UPS: On battery"
|
|
--#SUMMARY "The UPS has switched to battery backup power."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 5
|
|
|
|
smartBoostOn TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS has enabled SmartBoost(TM)."
|
|
--#TYPE "APC UPS: SmartBoost(TM)"
|
|
--#SUMMARY "The UPS has enabled SmartBoost(TM); low incoming line voltage."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 6
|
|
|
|
lowBattery TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The UPS batteries are low and will soon be exhausted.
|
|
If utility power is not restored the UPS will put itself
|
|
to 'sleep' and immediately cut power to the load."
|
|
--#TYPE "APC UPS: Low battery"
|
|
--#SUMMARY "The UPS system's batteries are low and will soon be exhausted."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 7
|
|
|
|
communicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communication with the UPS has been established."
|
|
--#TYPE "APC UPS: Communication established"
|
|
--#SUMMARY "UPS communication has been established."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 8
|
|
|
|
powerRestored TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Utility power has been restored."
|
|
--#TYPE "APC UPS: Utility power restored"
|
|
--#SUMMARY "Returned from battery backup power; utility power restored."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 9
|
|
|
|
upsDiagnosticsPassed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS passed its internal self-test."
|
|
--#TYPE "APC UPS: Passed self-test"
|
|
--#SUMMARY "The UPS passed internal self-test."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 10
|
|
|
|
returnFromLowBattery TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS has returned from a low battery
|
|
condition."
|
|
--#TYPE "APC UPS: Returned from Low-Battery condition"
|
|
--#SUMMARY "The UPS has returned from a Low-Battery condition."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 11
|
|
|
|
upsTurnedOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS has been turned 'off' by the management station."
|
|
--#TYPE "APC UPS: Turned off"
|
|
--#SUMMARY "The UPS has been switched off by a management station."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 12
|
|
|
|
upsSleeping TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS is entering 'sleep' mode. Power
|
|
to the load will be cut off."
|
|
--#TYPE "APC UPS: Entered sleep mode"
|
|
--#SUMMARY "The UPS entered sleep mode. Power to the load will be cut off."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 13
|
|
|
|
upsWokeUp TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS has returned from 'sleep' mode. Power
|
|
to the load has been restored."
|
|
--#TYPE "APC UPS: Wake up"
|
|
--#SUMMARY "The UPS has returned from sleep mode. Power to the load has been restored."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 14
|
|
|
|
upsRebootStarted TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS has started its reboot sequence.
|
|
The UPS will reboot itself at this time."
|
|
--#TYPE "APC UPS: Starting reboot"
|
|
--#SUMMARY "The UPS has started its reboot sequence."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 15
|
|
|
|
upsDipSwitchChanged TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The dip switch settings on the UPS have been
|
|
changed, possibly altering UPS performance."
|
|
--#TYPE "APC UPS: DIP switch altered"
|
|
--#SUMMARY "The DIP switch settings on the UPS have been changed."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 16
|
|
|
|
upsBatteryNeedsReplacement TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The batteries of the UPS need immediate replacement."
|
|
--#TYPE "APC UPS: UPS batteries need replacement"
|
|
--#SUMMARY "The UPS batteries require immediate replacement."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 17
|
|
|
|
|
|
-- the Environmental Monitor traps
|
|
|
|
contactFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: One of the contacts on the Environmental Monitor has
|
|
changed from its default position. The first variable is
|
|
the contact number that is faulted."
|
|
--#TYPE "APC Environment: Contact fault"
|
|
--#SUMMARY "An Environment contact closure has faulted."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 18
|
|
|
|
contactFaultResolved TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A fault on one of the Environmental Monitor contacts
|
|
has been resolved. The first variable is
|
|
the contact number that has been resolved."
|
|
--#TYPE "APC Environment: Contact fault cleared."
|
|
--#SUMMARY "A Environment contact closure has returned to it's default state."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 19
|
|
|
|
-- the Matrix-UPS traps
|
|
|
|
hardwareFailureBypass TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: UPS on bypass due to internal fault"
|
|
--#TYPE "APC UPS: On bypass due to internal fault"
|
|
--#SUMMARY "The UPS is on bypass due to an internal fault."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 20
|
|
|
|
softwareBypass TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: UPS on bypass - user set via software or panel"
|
|
--#TYPE "APC UPS: On bypass by user via software or panel"
|
|
--#SUMMARY "UPS put on bypass by user via software or front UPS panel."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 21
|
|
|
|
switchedBypass TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: UPS on bypass - initiated by user"
|
|
--#TYPE "APC UPS: On bypass initiated by user"
|
|
--#SUMMARY "UPS put on bypass by user."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 22
|
|
|
|
returnFromBypass TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: UPS has returned from bypass"
|
|
--#TYPE "APC UPS: UPS has returned from bypass"
|
|
--#SUMMARY "The UPS has returned from bypass mode."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 23
|
|
|
|
bypassPowerSupplyFailure TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Base module bypass power supply needs repair"
|
|
--#TYPE "APC UPS: Base module bypass power supply needs repair"
|
|
--#SUMMARY "The base module bypass power supply needs repair."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 24
|
|
|
|
baseFanFailure TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Base module fan needs repair"
|
|
--#TYPE "APC UPS: Base module fan needs repair"
|
|
--#SUMMARY "The base module fan needs repair."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 25
|
|
|
|
batteryPackCommLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Check installation of external battery packs signal cable"
|
|
--#TYPE "APC UPS: Communication lost with battery packs"
|
|
--#SUMMARY "Communication lost with external battery packs, check battery signal cable."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 26
|
|
|
|
batteryPackCommEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: UPS is communicating with the external battery packs."
|
|
--#TYPE "APC UPS: Communication established with battery packs"
|
|
--#SUMMARY "Communication established with external battery packs."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 27
|
|
|
|
calibrationStart TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A battery calibration test has been initiated on the UPS."
|
|
--#TYPE "APC UPS: Calibration initiated"
|
|
--#SUMMARY "A battery run time calibration test has been initiated."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 28
|
|
|
|
-- Misc. Traps
|
|
|
|
restartAgent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Agent restarting as commanded by manager."
|
|
--#TYPE "APC SNMP Agent: Agent restarting"
|
|
--#SUMMARY "Agent restarting as commanded by manager."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 29
|
|
|
|
upsTurnedOn TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A UPS is turned on."
|
|
--#TYPE "APC UPS: A UPS is turned on."
|
|
--#SUMMARY " A UPS is turned on."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 30
|
|
|
|
smartAvrReducing TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS is reducing the line voltage via SmartTrim(TM)."
|
|
--#TYPE "APC UPS: SmartTrim(TM) reducing"
|
|
--#SUMMARY "The UPS has enabled SmartTrim(TM) voltage reduction."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 31
|
|
|
|
codeAuthenticationDone TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mconfigTFTPServerIP, newCodeAuthentViaTFTP }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Authentication on agent code image is done."
|
|
--#TYPE "APC CODE: Authentication on agent code image is done."
|
|
--#SUMMARY "Authentication on agent code image is done."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 32
|
|
|
|
upsOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The overload condition has been cleared."
|
|
--#TYPE "APC UPS: Overload cleared."
|
|
--#SUMMARY "The overload condition has been cleared. ."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 33
|
|
|
|
smartBoostOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS has returned from SmartBoost(TM)."
|
|
--#TYPE "APC UPS: SmartBoost(TM) off."
|
|
--#SUMMARY "The UPS has returned from SmartBoost(TM)."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 34
|
|
|
|
smartAvrReducingOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS has returned from SmartTrim(TM)."
|
|
--#TYPE "APC UPS: SmartTrim(TM) reducing off"
|
|
--#SUMMARY "The UPS has returned from SmartTrim(TM) voltage reduction."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 35
|
|
|
|
upsBatteryReplaced TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A bad battery fault has been cleared."
|
|
--#TYPE "APC UPS: Bad battery replaced"
|
|
--#SUMMARY "The UPS has returned from a bad battery fault."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 36
|
|
|
|
calibrationEnd TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS has finished calibrating."
|
|
--#TYPE "APC UPS: Calibration end"
|
|
--#SUMMARY "The UPS has finished calibrating"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 37
|
|
|
|
dischargeCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A UPS discharge condition has been cleared."
|
|
--#TYPE "APC UPS: Discharge cleared."
|
|
--#SUMMARY "The UPS discharge condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 38
|
|
|
|
gracefulShutdown TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A graceful shutdown has been initiated."
|
|
--#TYPE "APC UPS: A graceful shutdown has been initiated."
|
|
--#SUMMARY "A graceful shutdown has been initiated."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 39
|
|
|
|
|
|
outletOn TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUOutletControlIndex }
|
|
DESCRIPTION
|
|
"WARNING: The specified PDU outlet has turned on.
|
|
If sPDUOutletControlIndex equals zero, then all outlets have
|
|
turned on."
|
|
--#TYPE "APC PDU: Outlet has been turned on."
|
|
--#SUMMARY "Outlet has been turned on"
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
|
|
outletOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUOutletControlIndex }
|
|
DESCRIPTION
|
|
"WARNING: The specified PDU outlet has turned off.
|
|
If sPDUOutletControlIndex equals zero, then all outlets
|
|
have turned off."
|
|
--#TYPE "APC PDU: Outlet has turned off."
|
|
--#SUMMARY "Outlet has turned off."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
outletReboot TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUOutletControlIndex }
|
|
DESCRIPTION
|
|
"WARNING: The specified PDU outlet has rebooted.
|
|
If sPDUOutletControlIndex equals zero, then all outlets
|
|
have rebooted."
|
|
--#TYPE "APC PDU: Outlet has rebooted."
|
|
--#SUMMARY "Outlet has rebooted."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
configChangeSNMP TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The SNMP configuration has been changed."
|
|
--#TYPE "APC: The SNMP configuration has been changed."
|
|
--#SUMMARY "The SNMP configuration has been changed."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
|
|
configChangeOutlet TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUOutletConfigIndex }
|
|
DESCRIPTION
|
|
"WARNING: The specified PDU outlet has changed configuration.
|
|
If sPDUOutletConfigIndex equals zero, then the Master outlet
|
|
has changed configuration."
|
|
--#TYPE "APC PDU: Outlet configuration has been changed."
|
|
--#SUMMARY "Outlet configuration has been changed."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
accessViolationConsole TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Someone has attempted to login via the console with the incorrect password."
|
|
--#TYPE "APC: Access violation via the console."
|
|
--#SUMMARY "Three unsuccessful logins have been attempted via the console."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
accessViolationHTTP TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Someone has attempted to login via HTTP with the incorrect password."
|
|
--#TYPE "APC: Access violation via HTTP."
|
|
--#SUMMARY "An unsuccessful attempt to login via HTTP."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
passwordChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The password for the device has been changed."
|
|
--#TYPE "APC: Password change for the device."
|
|
--#SUMMARY "Someone has changed the password on the device."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
badVoltage TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The output voltage is not within acceptable range."
|
|
--#TYPE "APC UPS: Bad output voltage."
|
|
--#SUMMARY "The output voltage is not within acceptable range."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
badVoltageCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The output voltage has returned to an acceptable level."
|
|
--#TYPE "APC UPS: The bad voltage output condition has been cleared."
|
|
--#SUMMARY "The output voltage has returned to an acceptable level."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
chargerFailure TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The battery charger has failed."
|
|
--#TYPE "APC UPS: The battery charger has failed."
|
|
--#SUMMARY "The battery charger has failed."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
chargerFailureCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The battery charger failure condition has been cleared."
|
|
--#TYPE "APC UPS: The battery charger failure condition cleared"
|
|
--#SUMMARY "The battery charger failure condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
batteryOverTemperature TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The battery temperature threshold has been violated."
|
|
--#TYPE "APC UPS: The battery temperature threshold has been violated."
|
|
--#SUMMARY "The battery temperature threshold has been violated."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 53
|
|
|
|
batteryOverTemperatureCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The battery over temperature has been cleared."
|
|
--#TYPE "APC UPS: The battery over temperature has been cleared."
|
|
--#SUMMARY "The battery over temperature has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 54
|
|
|
|
smartRelayFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: SmartBoost(TM) or SmartTrim(TM) relay fault."
|
|
--#TYPE "APC UPS: SmartBoost(TM) or SmartTrim(TM) relay fault."
|
|
--#SUMMARY "SmartBoost(TM) or SmartTrim(TM) relay fault."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 55
|
|
|
|
smartRelayFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared."
|
|
--#TYPE "APC UPS: SmartBoost(TM) or SmartTrim(TM) relay fault cleared."
|
|
--#SUMMARY "SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 56
|
|
|
|
humidityThresholdViolation1 TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Probe 1 humidity threshold violated. The
|
|
first variable is the current humidity."
|
|
--#TYPE "APC Environmental Monitor: Probe 1 humidity threshold violation"
|
|
--#SUMMARY "A humidity threshold has been violated on probe 1."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 57
|
|
|
|
humidityThresholdViolationCleared1 TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 1."
|
|
--#TYPE "APC Environmental Monitor: Probe 1 humidity violation cleared"
|
|
--#SUMMARY "A humidity threshold violation has been cleared on probe 1."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 58
|
|
|
|
temperatureThresholdViolation1 TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: An Environmental Monitor temperature threshold has been violated on probe 1.
|
|
The first variable is the current temperature."
|
|
--#TYPE "APC Environmental Monitor: Probe 1 temperature violation"
|
|
--#SUMMARY "A temperature threshold has been violated on probe 1."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 59
|
|
|
|
temperatureThresholdViolationCleared1 TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 1."
|
|
--#TYPE "APC Environmental Monitor: Probe 1 temperature violation cleared"
|
|
--#SUMMARY "A temperature threshold violation has been cleared on probe 1."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 60
|
|
|
|
humidityThresholdViolation2 TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: An Environmental Monitor humidity threshold has been violated on probe 2.
|
|
The first variable is the current humidity."
|
|
--#TYPE "APC Environmental Monitor: Probe 2 humidity violation"
|
|
--#SUMMARY "A humidity threshold has been violated on probe 2."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 61
|
|
|
|
humidityThresholdViolationCleared2 TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 2."
|
|
--#TYPE "APC Environmental Monitor: Probe 2 humidity violation cleared"
|
|
--#SUMMARY "A humidity threshold violation has been cleared on probe 2."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 62
|
|
|
|
temperatureThresholdViolation2 TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: An Environmental Monitor temperature threshold has been violated on probe 2.
|
|
The first variable is the current temperature."
|
|
--#TYPE "APC Environmental Monitor: Probe 2 temperature violation"
|
|
--#SUMMARY "A temperature threshold has been violated on probe 2."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 63
|
|
|
|
temperatureThresholdViolationCleared2 TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 2."
|
|
--#TYPE "APC Environmental Monitor: Probe 2 temperature violation cleared"
|
|
--#SUMMARY "A temperature threshold violation has been cleared on probe 2."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 64
|
|
|
|
mupsCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communication with the Environmental Monitor has been established."
|
|
--#TYPE "APC Environmental Monitor: Communication established"
|
|
--#SUMMARY "Communication established between the agent and the Environmental Monitor."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 65
|
|
|
|
mupsCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communication to the Environmental Monitor has been lost. Steps
|
|
to reestablish communication are in progress."
|
|
--#TYPE "APC Environmental Monitor: Communication failure"
|
|
--#SUMMARY "Communication lost between the agent and the Environmental Monitor."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 66
|
|
|
|
batteryIncrease TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The number of batteries has increased."
|
|
--#TYPE "APC UPS: The number of batteries has increased."
|
|
--#SUMMARY "The number of batteries has increased."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 67
|
|
|
|
batteryDecrease TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The number of batteries has decreased."
|
|
--#TYPE "APC UPS: The number of batteries has decreased."
|
|
--#SUMMARY "The number of batteries has decreased."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 68
|
|
|
|
powerModuleIncrease TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The number of power modules has increased."
|
|
--#TYPE "APC UPS: The number of power modules has increased."
|
|
--#SUMMARY "The number of power modules has increased."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 69
|
|
|
|
powerModuleDecrease TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The number of power modules has decreased."
|
|
--#TYPE "APC UPS: The number of power modules has decreased."
|
|
--#SUMMARY "The number of power modules has decreased."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 70
|
|
|
|
intelligenceModuleInserted TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An intelligence module has been inserted."
|
|
--#TYPE "APC UPS: An intelligence module has been inserted."
|
|
--#SUMMARY "An intelligence module has been inserted."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
intelligenceModuleRemoved TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An intelligence module has been removed."
|
|
--#TYPE "APC UPS: An intelligence module has been removed."
|
|
--#SUMMARY "An intelligence module has been removed."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
rintelligenceModuleInserted TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A redundant intelligence module has been inserted."
|
|
--#TYPE "APC UPS: A redundant intelligence module has been inserted."
|
|
--#SUMMARY "A redundant intelligence module has been inserted."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
rintelligenceModuleRemoved TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A redundant intelligence module has been removed."
|
|
--#TYPE "APC UPS: A redundant intelligence module has been removed."
|
|
--#SUMMARY "A redundant intelligence module has been removed."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
extBatteryFrameIncease TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An external battery frame has been added."
|
|
--#TYPE "APC UPS: An external battery frame has been added."
|
|
--#SUMMARY "An external battery frame has been added."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
extBatteryFrameDecrease TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An external battery frame has been removed."
|
|
--#TYPE "APC UPS: An external battery frame has been removed."
|
|
--#SUMMARY "An external battery frame has been removed."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
abnormalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: An abnormal condition has been detected.
|
|
The first variable is the fault condition."
|
|
--#TYPE "APC: An abnormal condition has been detected."
|
|
--#SUMMARY "An abnormal condition has been detected."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
abnormalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An abnormal condition has been cleared.
|
|
The first variable is the fault condition."
|
|
--#TYPE "APC: An abnormal condition has been cleared."
|
|
--#SUMMARY "An abnormal condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
deviceStatusChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The status of the device being monitored has changed."
|
|
--#TYPE "APC : The status of the device being monitored has changed."
|
|
--#SUMMARY "The status of the device being monitored has changed."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
noBatteries TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS has no batteries attached."
|
|
--#TYPE "APC UPS: No batteries attached."
|
|
--#SUMMARY "The UPS has no batteries attached."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
noBatteriesCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS's batteries have been attached."
|
|
--#TYPE "APC UPS: The no batteries attached condition has been cleared."
|
|
--#SUMMARY "The UPS's batteries have been attached."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
userAdded TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A new user has been added."
|
|
--#TYPE "APC: A new user has been added."
|
|
--#SUMMARY "A new user has been added."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
userDeleted TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A user has been deleted."
|
|
--#TYPE "APC: A user has been deleted."
|
|
--#SUMMARY "A user has been deleted."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 83
|
|
|
|
userModified TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A user has been modified."
|
|
--#TYPE "APC: A user has been modified."
|
|
--#SUMMARY "A user has been modified."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 84
|
|
|
|
-- MasterSwitch Vm Traps
|
|
|
|
msvmCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communications with the MasterSwitch VM has been established."
|
|
--#TYPE "APC: Communications established with the MasterSwitch VM."
|
|
--#SUMMARY "Communications with the MasterSwitch VM has been established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 85
|
|
|
|
msvmCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communications with the MasterSwitch VM has been lost."
|
|
--#TYPE "APC: Communications lost with the MasterSwitch VM."
|
|
--#SUMMARY "Communications with the MasterSwitch VM has been lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 86
|
|
|
|
msvmOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The MasterSwitch VM in an overload condition."
|
|
--#TYPE "APC: The MasterSwitch VM is near or at an overload condition."
|
|
--#SUMMARY "The MasterSwitch VM is near or at an overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 87
|
|
|
|
msvmOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The overload condition on the MasterSwitch VM has been cleared."
|
|
--#TYPE "APC: The overload condition cleared on the MasterSwitch VM."
|
|
--#SUMMARY "The overload condition on the MasterSwitch VM has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 88
|
|
|
|
msvmOutletOn TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName,
|
|
sPDUOutletControlVMOutletIndex, sPDUOutletControlVMOutletName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on the MasterSwitch VM has turned on."
|
|
--#TYPE "APC: An outlet on the MasterSwitch VM has turned on."
|
|
--#SUMMARY "An outlet on the MasterSwitch VM has turned on."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 89
|
|
|
|
msvmOutletOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName,
|
|
sPDUOutletControlVMOutletIndex, sPDUOutletControlVMOutletName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on the MasterSwitch VM has turned off."
|
|
--#TYPE "APC: An outlet on the MasterSwitch VM has turned off."
|
|
--#SUMMARY "An outlet on the MasterSwitch VM has turned off."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 90
|
|
|
|
msvmDeviceConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A device configuration change has been made on a MasterSwitch VM."
|
|
--#TYPE "APC: A device configuration change on a MasterSwitch VM."
|
|
--#SUMMARY "A device configuration change has been made on a MasterSwitch VM."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 91
|
|
|
|
msvmOutletConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName,
|
|
sPDUOutletControlVMOutletIndex, sPDUOutletControlVMOutletName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch VM."
|
|
--#TYPE "APC: An outlet configuration change on a MasterSwitch VM."
|
|
--#SUMMARY "An outlet configuration change has been made on a MasterSwitch VM."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 92
|
|
|
|
msvmLowLoad TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The MasterSwitch VM has violated the low load threshold."
|
|
--#TYPE "APC: The MasterSwitch VM has violated the low load threshold."
|
|
--#SUMMARY "The MasterSwitch VM has violated the low load threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 93
|
|
|
|
msvmLowLoadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The low load condition on the MasterSwitch VM has been cleared."
|
|
--#TYPE "APC: The low load condition cleared on the MasterSwitch VM."
|
|
--#SUMMARY "The low load condition on the MasterSwitch VM has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 94
|
|
|
|
msvmNearOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The MasterSwitch VM is approaching an overload condition."
|
|
--#TYPE "APC: The MasterSwitch VM is near or at an overload condition."
|
|
--#SUMMARY "The MasterSwitch VM is near or at an overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 95
|
|
|
|
msvmNearOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The near overload condition on the MasterSwitch VM has been cleared."
|
|
--#TYPE "APC: The overload condition cleared on the MasterSwitch VM."
|
|
--#SUMMARY "The overload condition on the MasterSwitch VM has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 96
|
|
|
|
msvmPowerSupplyStatusChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The power supply status of the MasterSwitch VM has changed."
|
|
--#TYPE "APC: The power supply status changed on MasterSwitch VM"
|
|
--#SUMMARY "The power supply status of the MasterSwitch VM has changed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 97
|
|
|
|
-- MasterSwitch plus (MSP) Traps
|
|
|
|
mspCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communications with the MasterSwitch plus has been established."
|
|
--#TYPE "APC: Communications established with the MasterSwitch plus."
|
|
--#SUMMARY "Communications with the MasterSwitch plus has been established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 98
|
|
|
|
mspCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communications with the MasterSwitch plus has been lost."
|
|
--#TYPE "APC: Communications lost with the MasterSwitch plus."
|
|
--#SUMMARY "Communications with the MasterSwitch plus has been lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 99
|
|
|
|
mspOutletOn TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName,
|
|
sPDUOutletControlMSPOutletIndex, sPDUOutletControlMSPOutletName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on the MasterSwitch plus has turned on."
|
|
--#TYPE "APC: An outlet on the MasterSwitch plus has turned on."
|
|
--#SUMMARY "An outlet on the MasterSwitch plus has turned on."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 100
|
|
|
|
mspOutletOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName,
|
|
sPDUOutletControlMSPOutletIndex, sPDUOutletControlMSPOutletName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on the MasterSwitch plus has turned off."
|
|
--#TYPE "APC: An outlet on the MasterSwitch plus has turned off."
|
|
--#SUMMARY "An outlet on the MasterSwitch plus has turned off."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 101
|
|
|
|
mspDeviceConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A device configuration change has been made on a MasterSwitch plus."
|
|
--#TYPE "APC: A device configuration change on a MasterSwitch plus."
|
|
--#SUMMARY "A device configuration change has been made on a MasterSwitch plus."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 102
|
|
|
|
mspOutletConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, sPDUOutletControlMSPOutletIndex, sPDUOutletControlMSPOutletName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch plus."
|
|
--#TYPE "APC: An outlet configuration change on a MasterSwitch plus."
|
|
--#SUMMARY "An outlet configuration change has been made on a MasterSwitch plus."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 103
|
|
|
|
rsSourceSwitched TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger02, mtrapargsString03, mtrapargsInteger, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The Redundant Switch has switched source.
|
|
The first variable is an integer representing the current source: 0=A, 1=B.
|
|
The second variable is the 32-character name of the current source.
|
|
The third variable is an integer representing the transfer cause:
|
|
0=No Transfers Recorded, 1=Due to user action or preferred switching,
|
|
3=Due to line notch or spike, 5=Due to low line voltage,
|
|
7=Transfer due to high line voltage,
|
|
9=Transfer due to frequency out of range.
|
|
The fourth variable is a character string listing the transfer cause."
|
|
--#TYPE "APC Redundant Switch: The Redundant Switch has switched source"
|
|
--#SUMMARY "The Redundant Switch has switched source."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 104
|
|
|
|
rsLostRedundancy TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The Redundant Switch has lost redundancy.
|
|
The first variable is an integer representing the source which is no longer available: 0=A, 1=B.
|
|
The second variable is the 32-character name of the source which is no longer available."
|
|
--#TYPE "APC Redundant Switch: The Redundant Switch has lost redundancy"
|
|
--#SUMMARY "The Redundant Switch has lost redundancy."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 105
|
|
|
|
rsRedundancyRestored TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Redundancy has been restored to the Redundant Switch .
|
|
The first variable is an integer representing the source which has been restored: 0=A, 1=B.
|
|
The second variable is the 32-character name of the source which has been restored."
|
|
--#TYPE "APC Redundant Switch: Redundancy has been restored."
|
|
--#SUMMARY "Redundancy has been restored to the Redundant Switch ."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 106
|
|
|
|
rsConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A configuration change has been made on a Redundant Switch."
|
|
--#TYPE "APC: A configuration change on a Redundant Switch."
|
|
--#SUMMARY "A configuration change has been made on a Redundant Switch."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 107
|
|
|
|
rsCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communications with the Redundant Switch has been established."
|
|
--#TYPE "APC: Communications established with the Redundant Switch."
|
|
--#SUMMARY "Communications with the Redundant Switch has been established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 108
|
|
|
|
rsCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communications with the Redundant Switch has been lost."
|
|
--#TYPE "APC: Communications lost with the Redundant Switch."
|
|
--#SUMMARY "Communications with the Redundant Switch has been lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 109
|
|
|
|
dcCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communications with the DC power plant has been established."
|
|
--#TYPE "APC: Communications established with the DC power plant."
|
|
--#SUMMARY "Communications with the DC power plant has been established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 110
|
|
|
|
dcCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communications with the DC power plant has been lost."
|
|
--#TYPE "APC: Communications lost with the DC power plant."
|
|
--#SUMMARY "Communications with the DC power plant has been lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 111
|
|
|
|
dcPINChanged TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The active PIN on the DC controller has been changed."
|
|
--#TYPE "APC: The active PIN on the DC controller has been changed."
|
|
--#SUMMARY "The active PIN on the DC controller has been changed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 112
|
|
|
|
dcMajorAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A Major alarm is active in the DC power plant."
|
|
--#TYPE "APC: A Major alarm is active in the DC power plant."
|
|
--#SUMMARY "A Major alarm is active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 113
|
|
|
|
dcMajorAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Major alarm is no longer active in the DC power plant."
|
|
--#TYPE "APC: A Major alarm is no longer active in the DC power plant."
|
|
--#SUMMARY "A Major alarm is no longer active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 114
|
|
|
|
dcMinorAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Minor alarm is active in the DC power plant."
|
|
--#TYPE "APC: A Minor alarm is active in the DC power plant."
|
|
--#SUMMARY "A Minor alarm is active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 115
|
|
|
|
dcMinorAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Minor alarm is no longer active in the DC power plant."
|
|
--#TYPE "APC: A Minor alarm is no longer active in the DC power plant."
|
|
--#SUMMARY "A Minor alarm is no longer active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 116
|
|
|
|
dcOutputRelayOn TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { dm3StatusOutRlyIndex, dm3StatusOutRlyName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An output relay for the powerplant has been activated (state changed to on).
|
|
The first variable is an integer representing the output relay number that has gone on.
|
|
The second variable is the 16-character name of the output relay."
|
|
--#TYPE "APC: An output relay has gone on."
|
|
--#SUMMARY "An output relay has gone on in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 117
|
|
|
|
dcOutputRelayOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { dm3StatusOutRlyIndex, dm3StatusOutRlyName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An output relay for the powerplant has been deactivated (state changed to off).
|
|
The first variable is an integer representing the output relay number that has gone off.
|
|
The second variable is the 16-character name of the output relay."
|
|
--#TYPE "APC: An output relay has gone off."
|
|
--#SUMMARY "An output relay has gone off in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 118
|
|
|
|
dcInputRelayOn TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { dm3StatusInRlyIndex, dm3StatusInRlyName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An input relay for the powerplant has been activated (state changed to on).
|
|
The first variable is an integer representing the input relay number that has gone on.
|
|
The second variable is the 16-character name of the input relay."
|
|
--#TYPE "APC: An input relay has gone on."
|
|
--#SUMMARY "An input relay has gone on in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 119
|
|
|
|
dcInputRelayOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { dm3StatusInRlyIndex, dm3StatusInRlyName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An input relay for the powerplant has been deactivated (state changed to off).
|
|
The first variable is an integer representing the input relay number that has gone off.
|
|
The second variable is the 16-character name of the input relay."
|
|
--#TYPE "APC: An input relay has gone off."
|
|
--#SUMMARY "An input relay has gone off in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 120
|
|
|
|
logicPowerSuppliesIncreased TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The number of system power supplies has increased."
|
|
--#TYPE "APC UPS: The number of system power supplies has increased."
|
|
--#SUMMARY "The number of system power supplies has increased."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 121
|
|
|
|
logicPowerSuppliesDecreased TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The number of system power supplies has decreased."
|
|
--#TYPE "APC UPS: The number of system power supplies has decreased."
|
|
--#SUMMARY "The number of system power supplies has decreased."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 122
|
|
|
|
externalSwitchGearClosed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: External Switch Gear closed."
|
|
--#TYPE "APC UPS: External Switch Gear closed."
|
|
--#SUMMARY "External Switch Gear closed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 123
|
|
|
|
externalSwitchGearOpened TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: External Switch Gear opened."
|
|
--#TYPE "APC UPS: External Switch Gear opened."
|
|
--#SUMMARY "External Switch Gear opened."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 124
|
|
|
|
generalDeviceEvent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: APC Device event."
|
|
--#TYPE "APC Device event"
|
|
--#SUMMARY "APC Device event."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 125
|
|
|
|
atsSourceSwitched TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The Automatic Transfer Switch has switched source.
|
|
The first variable is an integer representing the current source: 0=A, 1=B.
|
|
The second variable is the 32-character name of the current source."
|
|
--#TYPE "APC Automatic Transfer Switch: The ATS has switched source"
|
|
--#SUMMARY "The Automatic Transfer Switch has switched source."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 126
|
|
|
|
atsLostRedundancy TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The Automatic Transfer Switch has lost redundancy.
|
|
The first variable is an integer representing the source which is no longer available: 0=A, 1=B.
|
|
The second variable is the 32-character name of the source which is no longer available."
|
|
--#TYPE "APC Automatic Transfer Switch: The ATS has lost redundancy. "
|
|
--#SUMMARY "The Automatic Transfer Switch has lost redundancy."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 127
|
|
|
|
atsRedundancyRestored TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Redundancy has been restored to the Automatic Transfer Switch .
|
|
The first variable is an integer representing the source which has been restored: 0=A, 1=B.
|
|
The second variable is the 32-character name of the source which has been restored."
|
|
--#TYPE "APC Automatic Transfer Switch: Redundancy has been restored."
|
|
--#SUMMARY "Redundancy has been restored to the Automatic Transfer Switch ."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 128
|
|
|
|
atsConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A configuration change has been made on the Automatic Transfer Switch.
|
|
The first variable is an integer representing the configuration setting which changed:
|
|
0=Transfer Voltage Range, 1=Sensitivity, 2=Preferred Source
|
|
3=Front Panel Lockout, 4=Current Limit, 5=Reset XA Processor,
|
|
6=Reset to defaults, 7=Product Name, 8=Nominal Voltage, 9=Nominal Line Frequency,
|
|
10=Narrow VRMS, 11=Medium VRMS, 12=Wide VRMS,13=Frequency Deviation,
|
|
14=ColdStart ATS, 15=Events Count Cleared, 16=Phase or Bank Threshold. "
|
|
--#TYPE "APC Automatic Transfer Switch: ATS configuration changed."
|
|
--#SUMMARY "A configuration change has been made on a Automatic Transfer Switch."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 129
|
|
|
|
atsCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communications with the Automatic Transfer Switch has been established."
|
|
--#TYPE "APC Automatic Transfer Switch: Communications established."
|
|
--#SUMMARY "Communications with the Automatic Transfer Switch has been established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 130
|
|
|
|
atsCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communications with the Automatic Transfer Switch has been lost."
|
|
--#TYPE "APC Automatic Transfer Switch: Communications lost."
|
|
--#SUMMARY "Communications with the Automatic Transfer Switch has been lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 131
|
|
|
|
atsOverCurrent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Output Current has exceeded threshold. This is same as atsOverload Trap
|
|
for phase or total in case banked units"
|
|
|
|
--#TYPE "APC Automatic Transfer Switch: Output Current exceeded threshold"
|
|
--#SUMMARY "Output Current has exceeded Threshold. "
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 132
|
|
|
|
atsOverCurrentCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Output Current has returned below threshold.This is same as atsOverloadCleared Trap
|
|
for phase or total in case banked units"
|
|
--#TYPE "APC Automatic Transfer Switch: Output Current below threshold."
|
|
--#SUMMARY "Output Current has returned below threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 133
|
|
|
|
atsPowerSupplyFailure TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The Automatic Transfer Switch Power Supply has failed.
|
|
The first variable is an integer representing the Power Supply which
|
|
has failed: 0 = Source A 24V,
|
|
1 = 12V,
|
|
2 = 5V,
|
|
3 = Source B 24V."
|
|
--#TYPE "APC Automatic Transfer Switch: The ATS Power Supply has failed."
|
|
--#SUMMARY "The Automatic Transfer Switch Power Supply has failed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 134
|
|
|
|
atsPowerSupplyFailureCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The Automatic Transfer Power Supply Failure Cleared.
|
|
The first variable is an integer representing the Power Supply which
|
|
has cleared: 0 = Source A 24V,
|
|
1 = 12V,
|
|
2 = 5V,
|
|
3 = Source B 24V."
|
|
--#TYPE "APC Automatic Transfer Switch: Power Supply Failure Cleared."
|
|
--#SUMMARY "The Automatic Transfer Switch Power Supply Failure Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 135
|
|
|
|
dcMainsFailAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Mains Fail alarm is active in the DC power plant."
|
|
--#TYPE "APC: A Mains Fail alarm is active in the DC power plant."
|
|
--#SUMMARY "A Mains Fail alarm is active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 136
|
|
|
|
dcMainsFailAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Mains Fail alarm is no longer active in the DC power plant."
|
|
--#TYPE "APC: Mains Fail alarm is no longer active in the DC power plant."
|
|
--#SUMMARY "Mains Fail alarm is no longer active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 137
|
|
|
|
dcFanFailAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Fan Fail alarm is active in the DC power plant."
|
|
--#TYPE "APC: A Fan Fail alarm is active in the DC power plant."
|
|
--#SUMMARY "A Fan Fail alarm is active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 138
|
|
|
|
dcFanFailAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Fan Fail alarm is no longer active in the DC power plant."
|
|
--#TYPE "APC: A Fan Fail alarm is no longer active in the DC power plant."
|
|
--#SUMMARY "A Fan Fail alarm is no longer active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 139
|
|
|
|
dcRectifierOvertempAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Rect. Overtemp alarm is active in the power plant."
|
|
--#TYPE "APC: Rect. Overtemp alarm is active in the power plant."
|
|
--#SUMMARY "Rect. Overtemp alarm is active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 140
|
|
|
|
dcRectifierOvertempAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Rect. Overtemp alarm is no longer active in the power plant."
|
|
--#TYPE "APC: Rect. Overtmp alarm is no longer active in the power plant."
|
|
--#SUMMARY "Rect. Overtemp alarm is no longer active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 141
|
|
|
|
dcCurrentLimitAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Current Limit alarm is active in the power plant."
|
|
--#TYPE "APC: A Current Limit alarm is active in the power plant."
|
|
--#SUMMARY "A Current Limit alarm is active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 142
|
|
|
|
dcCurrentLimitAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Current Limit alarm is no longer active in the power plant."
|
|
--#TYPE "APC: Current Limit alarm is no longer active in the power plant."
|
|
--#SUMMARY "Current Limit alarm is no longer active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 143
|
|
|
|
dcRectifierFailAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Rect. Fail alarm is active in the power plant."
|
|
--#TYPE "APC: A Rect. Fail alarm is active in the power plant."
|
|
--#SUMMARY "A Rect. Fail alarm is active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 144
|
|
|
|
dcRectifierFailAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Rect. Fail alarm is no longer active in the power plant."
|
|
--#TYPE "APC: Rect. Fail alarm is no longer active in the power plant."
|
|
--#SUMMARY "Rect. Fail alarm is no longer active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 145
|
|
|
|
dcMultRectFailAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Multiple Rect. Fail alarm is active in the powerplant."
|
|
--#TYPE "APC: Multiple Rect. Fail alarm is active in the powerplant."
|
|
--#SUMMARY "Multiple Rect. Fail alarm is active in the powerplant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 146
|
|
|
|
dcMultRectFailAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Multiple Rect Fail alarm is no longer active in the powerplant."
|
|
--#TYPE "APC: Multiple Rect Fail alarm is no longer active in powerplant."
|
|
--#SUMMARY "Multiple Rect Fail alarm is no longer active in the powerplant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 147
|
|
|
|
dcBatteryBreakerAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Batt. Breaker alarm is active in the power plant."
|
|
--#TYPE "APC: Batt. Breaker alarm is active in the power plant."
|
|
--#SUMMARY "Batt. Breaker alarm is active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 148
|
|
|
|
dcBatteryBreakerAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Batt. Breaker alarm is no longer active in the power plant."
|
|
--#TYPE "APC: Batt. Breaker alarm is no longer active in the power plant."
|
|
--#SUMMARY "Batt. Breaker alarm is no longer active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 149
|
|
|
|
dcRectifierOVPAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Rect. OVP alarm is active in the power plant."
|
|
--#TYPE "APC: A Rect. OVP alarm is active in the power plant."
|
|
--#SUMMARY "A Rect. OVP alarm is active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 150
|
|
|
|
dcRectifierOVPAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Rect. OVP alarm is no longer active in the power plant."
|
|
--#TYPE "APC: A Rect. OVP alarm is no longer active in the power plant."
|
|
--#SUMMARY "A Rect. OVP alarm is no longer active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 151
|
|
|
|
dcLVDImminentAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A LVD Imminent alarm is active in the powerplant."
|
|
--#TYPE "APC: A LVD Imminent alarm is active in the powerplant."
|
|
--#SUMMARY "A LVD Imminent alarm is active in the powerplant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 152
|
|
|
|
dcLVDImminentAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A LVD Imminent alarm is no longer active in the powerplant."
|
|
--#TYPE "APC: A LVD Imminent alarm is no longer active in the powerplant."
|
|
--#SUMMARY "A LVD Imminent alarm is no longer active in the powerplant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 153
|
|
|
|
dcFuseCBAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Fuse/CB alarm is active in the DC power plant."
|
|
--#TYPE "APC: A Fuse/CB alarm is active in the DC power plant."
|
|
--#SUMMARY "A Fuse/CB alarm is active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 154
|
|
|
|
dcFuseCBAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Fuse/CB alarm is no longer active in the DC power plant."
|
|
--#TYPE "APC: A Fuse/CB alarm is no longer active in the DC power plant."
|
|
--#SUMMARY "A Fuse/CB alarm is no longer active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 155
|
|
|
|
dcBatteryTestFail TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Battery Test failed in the DC power plant."
|
|
--#TYPE "APC: A Battery Test failed in the DC power plant."
|
|
--#SUMMARY "A Battery Test failed in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 156
|
|
|
|
dcTemperatureAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Temperature is active in the power plant."
|
|
--#TYPE "APC: A Temperature alarm is active in the power plant."
|
|
--#SUMMARY "A Temperature alarm is active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 157
|
|
|
|
dcTemperatureAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Temperature alarm is no longer active in the power plant."
|
|
--#TYPE "APC: A Temperature alarm is no longer active in the power plant."
|
|
--#SUMMARY "A Temperature alarm is no longer active in the power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 158
|
|
|
|
dcHumidityAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Humidity alarm is active in the DC power plant."
|
|
--#TYPE "APC: A Humidity alarm is active in the DC power plant."
|
|
--#SUMMARY "A Humidity alarm is active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 159
|
|
|
|
dcHumidityAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Humidity alarm is no longer active in the DC power plant."
|
|
--#TYPE "APC: A Humidity alarm is no longer active in the DC power plant."
|
|
--#SUMMARY "A Humidity alarm is no longer active in the DC power plant."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 160
|
|
|
|
dcBBCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Power plant bridging board communications established."
|
|
--#TYPE "APC: Power plant bridging board communications established."
|
|
--#SUMMARY "Power plant bridging board communications established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 161
|
|
|
|
dcBBCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Power plant bridging board communications lost."
|
|
--#TYPE "APC: Power plant bridging board communications lost."
|
|
--#SUMMARY "Power plant bridging board communications lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 162
|
|
|
|
iemHighTempThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusProbeCurrentTemp, iemStatusProbeTempUnits, iemStatusProbeNumber,
|
|
iemStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: High temperature threshold violated on Integrated
|
|
Environmental Monitor probe. The first variable is the
|
|
current temperature. The second variable is the temperature
|
|
scale. The third variable is the probe number. The fourth
|
|
variable is the probe name."
|
|
--#TYPE "APC IEM: High temperature threshold violation."
|
|
--#SUMMARY "High temperature threshold violation."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 163
|
|
|
|
iemHighTempThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: High temperature threshold violated on Integrated
|
|
Environmental Monitor probe has been cleared. The first variable
|
|
is the probe number. The second variable is the probe name."
|
|
--#TYPE "APC IEM: High temperature threshold violation cleared."
|
|
--#SUMMARY "High temperature threshold violation has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 164
|
|
|
|
iemLowTempThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusProbeCurrentTemp, iemStatusProbeTempUnits, iemStatusProbeNumber,
|
|
iemStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Low temperature threshold violated on integrated
|
|
probe. The first variable is the current temperature. The
|
|
second variable is the temperature scale. The third
|
|
variable is the probe number. The fourth variable is the
|
|
probe name."
|
|
--#TYPE "APC IEM: Low temperature threshold violation."
|
|
--#SUMMARY "Low temperature threshold violation."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 165
|
|
|
|
iemLowTempThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Low temperature threshold violated on integrated
|
|
probe has been cleared. The first variable is the probe number.
|
|
The second variable is the probe name."
|
|
--#TYPE "APC IEM: Low temperature threshold violation cleared."
|
|
--#SUMMARY "Low temperature threshold violation has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 166
|
|
|
|
iemHighHumidThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusProbeCurrentHumid, iemStatusProbeNumber, iemStatusProbeName,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: High humidity threshold violated on integrated
|
|
probe. The first variable is the current humidity. The
|
|
second variable is the probe number. The third variable
|
|
is the probe name."
|
|
--#TYPE "APC IEM: High humidity threshold violation."
|
|
--#SUMMARY "High humidity threshold violation."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 167
|
|
|
|
iemHighHumidThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: High humidity threshold violated on integrated
|
|
probe cleared. The first variable is the probe number. The second
|
|
variable is the probe name."
|
|
--#TYPE "APC IEM: High humidity threshold violation cleared."
|
|
--#SUMMARY "High humidity threshold violation has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 168
|
|
|
|
iemLowHumidThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusProbeCurrentHumid, iemStatusProbeNumber, iemStatusProbeName,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Low humidity threshold violated on integrated
|
|
probe. The first variable is the current humidity. The
|
|
second variable is the probe number. The third variable
|
|
is the probe name."
|
|
--#TYPE "APC IEM: Low humidity threshold violation."
|
|
--#SUMMARY "Low humidity threshold violation."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 169
|
|
|
|
iemLowHumidThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Low humidity threshold violated on integrated
|
|
probe cleared. The first variable is the probe number. The second
|
|
variable is the probe name."
|
|
--#TYPE "APC IEM: Low humidity threshold violation cleared."
|
|
--#SUMMARY "Low humidity threshold violation has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 170
|
|
|
|
iemProbeDisconnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The temperature/humidity probe on the Integrated
|
|
Environmental Monitor has been disconnected. This trap is
|
|
generated when a probe that has been in communication with
|
|
the Environmental Monitor has been disconnected or can no
|
|
longer communicate."
|
|
--#TYPE "APC IEM: Probe disconnected."
|
|
--#SUMMARY "Probe has been disconnected."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 171
|
|
|
|
iemProbeConnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The temperature/humidity probe on the Integrated
|
|
Environmental Monitor has been connected. This trap is generated
|
|
when the Environmental Monitor establishes communication with a
|
|
probe that had previously not been connected."
|
|
--#TYPE "APC IEM: Probe Connected."
|
|
--#SUMMARY "Probe has been connected."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 172
|
|
|
|
iemContactFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusContactNumber, iemStatusContactName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: There is a contact fault on the Integrated
|
|
Environmental Monitor. The first argument is the number
|
|
of the contact. The second argument is the name of the
|
|
contact."
|
|
--#TYPE "APC IEM: Contact fault."
|
|
--#SUMMARY "Contact fault."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 173
|
|
|
|
iemContactFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusContactNumber, iemStatusContactName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The contact fault on the Integrated
|
|
Environmental Monitor has been cleared. The first
|
|
argument is the number of the contact. The second
|
|
argument is the name of the contact."
|
|
--#TYPE "APC IEM: Contact fault."
|
|
--#SUMMARY "Contact fault cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 174
|
|
|
|
iemRelayFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusRelayNumber, iemStatusRelayName, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The output relay on the Integrated Environmental
|
|
Monitor has switched to the fault state. The first
|
|
argument is the number of the output relay. The second
|
|
argument is the name of the output relay. The third
|
|
argument is the event that caused the fault."
|
|
--#TYPE "APC IEM: Output relay fault."
|
|
--#SUMMARY "Output relay has faulted."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 175
|
|
|
|
iemRelayFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { iemStatusRelayNumber, iemStatusRelayName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The fault condition on the output relay on the
|
|
Integrated Environmental Monitor has cleared. The first
|
|
argument is the number of the output relay. The second
|
|
argument is the name of the output relay."
|
|
--#TYPE "APC IEM: Output relay fault condition cleared."
|
|
--#SUMMARY "Output relay fault cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 176
|
|
|
|
bmBatManCommEstab TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Serial Communications Established with Battery Manager."
|
|
--#TYPE "BatMan : Communications Established."
|
|
--#SUMMARY "Communications Established."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 177
|
|
|
|
bmBatManCommLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Serial Communications Lost with Battery Manager."
|
|
--#TYPE "BatMan : Communications Lost."
|
|
--#SUMMARY "Communications Lost."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 178
|
|
|
|
bmBatManKneeAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Battery Voltage Knee Threshold Alarm Detected."
|
|
--#TYPE "BatMan : Knee Alarm Detected."
|
|
--#SUMMARY "Knee Alarm Detected."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 179
|
|
|
|
bmBatManKneeAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Battery Voltage Knee Threshold Alarm Cleared."
|
|
--#TYPE "BatMan : Knee Alarm Cleared."
|
|
--#SUMMARY "Knee Alarm Cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 180
|
|
|
|
bmBatManChargerAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Charger Alarm Detected."
|
|
--#TYPE "BatMan : Charger Alarm Detected."
|
|
--#SUMMARY "Charger Alarm Detected."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 181
|
|
|
|
bmBatManChargerAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Charger Alarm Cleared."
|
|
--#TYPE "BatMan : Charger Alarm Cleared."
|
|
--#SUMMARY "Charger Alarm Cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 182
|
|
|
|
bmBatManBatteryAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Battery Alarm Detected."
|
|
--#TYPE "BatMan : Battery Alarm Detected."
|
|
--#SUMMARY "Battery Alarm Detected."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 183
|
|
|
|
bmBatManBatteryAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Battery Alarm Cleared."
|
|
--#TYPE "BatMan : Battery Alarm Cleared."
|
|
--#SUMMARY "Battery Alarm Cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 184
|
|
|
|
bmBatManEnvironmentAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Environment Alarm Detected."
|
|
--#TYPE "BatMan : Environment Alarm Detected."
|
|
--#SUMMARY "Environment Alarm Detected."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 185
|
|
|
|
bmBatManEnvironmentAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Environment Alarm Cleared."
|
|
--#TYPE "BatMan : Environment Alarm Cleared."
|
|
--#SUMMARY "Environment Alarm Cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 186
|
|
|
|
bmBatManMaintenanceAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Maintenance Alarm Detected."
|
|
--#TYPE "BatMan : Maintenance Due Alarm Detected."
|
|
--#SUMMARY "Maintenance Due Alarm Detected."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 187
|
|
|
|
bmBatManMaintenanceAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Maintenance Alarm Cleared."
|
|
--#TYPE "BatMan : Maintenance Due Alarm Cleared."
|
|
--#SUMMARY "Maintenance Due Alarm Cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 188
|
|
|
|
pduCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communication Established.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Communication Established."
|
|
--#SUMMARY "Communication Established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 189
|
|
|
|
pduCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communication Lost.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Communication Lost."
|
|
--#SUMMARY "Communication Lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 190
|
|
|
|
pduUtilityLineUndervoltage TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Utility Line Undervoltage.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Utility Line Undervoltage."
|
|
--#SUMMARY "Utility Line Undervoltage."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 191
|
|
|
|
pduUtilityLineUndervoltageCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Utility Line Undervoltage Cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Utility Line Undervoltage Cleared."
|
|
--#SUMMARY "Utility Line Undervoltage Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 192
|
|
|
|
pduUtilityLineOvervoltage TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Utility Line Overvoltage.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Utility Line Overvoltage."
|
|
--#SUMMARY "Utility Line Overvoltage."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 193
|
|
|
|
pduUtilityLineOvervoltageCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Utility Line Overvoltage Cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Utility Line Overvoltage Cleared."
|
|
--#SUMMARY "Utility Line Overvoltage Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 194
|
|
|
|
pduGroundOvercurrent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Ground Overcurrent.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Ground Overcurrent."
|
|
--#SUMMARY "Ground Overcurrent."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 195
|
|
|
|
pduGroundOvercurrentCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Ground Overcurrent Cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Ground Overcurrent Cleared."
|
|
--#SUMMARY "Ground Overcurrent Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 196
|
|
|
|
pduCircuitPanelInputUndervoltage TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Circuit Panel Input Undervoltage.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Circuit Panel Input Undervoltage."
|
|
--#SUMMARY "Circuit Panel Input Undervoltage."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 197
|
|
|
|
pduCircuitPanelInputUndervoltageCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Circuit Panel Input Undervoltage Cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Circuit Panel Input Undervoltage Cleared."
|
|
--#SUMMARY "Circuit Panel Input Undervoltage Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 198
|
|
|
|
pduCircuitPanelInputOvervoltage TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Circuit Panel Input Overvoltage.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Circuit Panel Input Overvoltage."
|
|
--#SUMMARY "Circuit Panel Input Overvoltage."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 199
|
|
|
|
pduCircuitPanelInputOvervoltageCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Circuit Panel Input Overvoltage Cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Circuit Panel Input Overvoltage Cleared."
|
|
--#SUMMARY "Circuit Panel Input Overvoltage Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 200
|
|
|
|
pduCircuitPanelInputUndercurrent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Circuit Panel Input Undercurrent.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Circuit Panel Input Undercurrent."
|
|
--#SUMMARY "Circuit Panel Input Undercurrent."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 201
|
|
|
|
pduCircuitPanelInputUndercurrentCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Circuit Panel Input Undercurrent Cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Circuit Panel Input Undercurrent Cleared."
|
|
--#SUMMARY "Circuit Panel Input Undercurrent Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 202
|
|
|
|
pduCircuitPanelInputOvercurrent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Circuit Panel Input Overcurrent.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Circuit Panel Input Overcurrent."
|
|
--#SUMMARY "Circuit Panel Input Overcurrent."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 203
|
|
|
|
pduCircuitPanelInputOvercurrentCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Circuit Panel Input Overcurrent Cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: Circuit Panel Input Overcurrent Cleared."
|
|
--#SUMMARY "Circuit Panel Input Overcurrent Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 204
|
|
|
|
pduCircuitPanelFrequencyOutOfRange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Circuit Panel Input Frequency Out Of Range.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Circuit Panel Input Frequency Out Of Range."
|
|
--#SUMMARY "Circuit Panel Input Frequency Out Of Range."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 205
|
|
|
|
pduCircuitPanelFrequencyOutofRangeCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Circuit Panel Input Frequency No Longer Out Of Range.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Circuit Panel Input Frequency No Longer Out Of Range."
|
|
--#SUMMARY "Circuit Panel Input Frequency No Longer Out Of Range."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 206
|
|
|
|
pduCircuitPanelNeutralOvercurrent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Circuit Panel Input Neutral Overcurrent.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Circuit Panel Input Neutral Overcurrent."
|
|
--#SUMMARY "Circuit Panel Input Neutral Overcurrent."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 207
|
|
|
|
pduCircuitPanelNeutralOvercurrentCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Circuit Panel Input Neutral Overcurrent Cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Circuit Panel Input Neutral Overcurrent Cleared."
|
|
--#SUMMARY "Circuit Panel Input Neutral Overcurrent Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 208
|
|
|
|
pduSystemOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: PDU System Off.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: System Off."
|
|
--#SUMMARY "PDU System Off."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 209
|
|
|
|
pduOnBatteryMode TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: PDU is in On Battery Mode.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: On Battery Mode."
|
|
--#SUMMARY "PDU is in On Battery Mode."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 210
|
|
|
|
pduMaintenanceBypassMode TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: PDU is in Maintenance Bypass Mode.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Maintenance Bypass Mode."
|
|
--#SUMMARY "PDU is in Maintenance Bypass Mode."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 211
|
|
|
|
pduAtypicalBypassMode TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: PDU is in Atypical Bypass Mode.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Atypical Bypass Mode."
|
|
--#SUMMARY "PDU is in Atypical Bypass Mode."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 212
|
|
|
|
pduNoPanelFeedMode TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: PDU is in No Panel Feed Mode.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: No Panel Feed Mode."
|
|
--#SUMMARY "PDU is in No Panel Feed Mode."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 213
|
|
|
|
pduUpsOperationMode TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: PDU is in Ups Operation Mode.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Ups Operation Mode."
|
|
--#SUMMARY "PDU is in Ups Operation Mode."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 214
|
|
|
|
pduForcedBypassMode TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: PDU is in Forced Bypass Mode.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Forced Bypass Mode."
|
|
--#SUMMARY "PDU is in Forced Bypass Mode."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 215
|
|
|
|
pduInputTransformerOverTemperature TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Input Transformer Over Temperature.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Input Transformer Over Temperature."
|
|
--#SUMMARY "Input Transformer Over Temperature."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 216
|
|
|
|
pduInputTransformerOverTemperatureCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Input Transformer Over Temperature Cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC PDU: Input Transformer Over Temperature Cleared."
|
|
--#SUMMARY "Input Transformer Over Temperature Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 217
|
|
|
|
pduUPSInputVoltageLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: UPS Input Voltage phase-N Lost.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: UPS Input Voltage phase-N Lost."
|
|
--#SUMMARY "UPS Input Voltage phase-N Lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 218
|
|
|
|
pduUPSInputVoltageRestored TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: UPS Input Voltage phase-N Restored.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC PDU: UPS Input Voltage phase-N Restored."
|
|
--#SUMMARY "UPS Input Voltage phase-N Restored."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 219
|
|
|
|
pduContactFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A contact closure in the PDU is in an abnormal position.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the number of the contact."
|
|
--#TYPE "APC PDU: Contact Abnormal."
|
|
--#SUMMARY "Contact Abnormal."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 220
|
|
|
|
pduContactFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A contact closure in the PDU is in a normal position.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the number of the contact."
|
|
--#TYPE "APC PDU: Contact Normal."
|
|
--#SUMMARY "Contact Normal."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 221
|
|
|
|
rPDUBankPhaseLowLoad TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A bank or phase on the Rack PDU has violated the low load threshold.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank number (0 if this is phase data).
|
|
The fourth argument is the phase number (0 if this is bank data)."
|
|
--#TYPE "APC Rack PDU: Violation of bank or phase low load threshold."
|
|
--#SUMMARY "A bank or phase on the Rack PDU has violated the low load threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 222
|
|
|
|
rPDUBankPhaseLowLoadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The bank or phase low load condition on a Rack PDU has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank number (0 if this is phase data).
|
|
The fourth argument is the phase number (0 if this is bank data)."
|
|
--#TYPE "APC Rack PDU: Bank or phase low load condition cleared."
|
|
--#SUMMARY "The bank or phase low load condition on a Rack PDU has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 223
|
|
|
|
rPDUBankPhaseNearOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A bank or phase of the Rack PDU is near an overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank number (0 if this is phase data).
|
|
The fourth argument is the phase number (0 if this is bank data)."
|
|
--#TYPE "APC Rack PDU: Bank or phase near an overload condition."
|
|
--#SUMMARY "A bank or phase of the Rack PDU is near an overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 224
|
|
|
|
rPDUBankPhaseNearOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The bank or phase near overload condition on a Rack PDU has
|
|
been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank number (0 if this is phase data).
|
|
The fourth argument is the phase number (0 if this is bank data)."
|
|
--#TYPE "APC Rack PDU: Bank or phase near overload condition has cleared."
|
|
--#SUMMARY "Rack PDU bank or phase near overload condition has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 225
|
|
|
|
rPDUBankPhaseOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A bank or phase of the Rack PDU is in an overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number.
|
|
The third argument is the bank number (0 if this is phase data).
|
|
The fourth argument is the phase number (0 if this is bank data)."
|
|
--#TYPE "APC Rack PDU: Bank or phase overload condition."
|
|
--#SUMMARY "A bank or phase of the Rack PDU is in an overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 226
|
|
|
|
rPDUBankPhaseOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The bank or phase overload condition on a Rack PDU has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank number (0 if this is phase data).
|
|
The fourth argument is the phase number (0 if this is bank data)."
|
|
--#TYPE "APC Rack PDU: Bank or phase overload condition has cleared."
|
|
--#SUMMARY "The bank or phase overload condition on a Rack PDU has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 227
|
|
|
|
aruDeviceConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Remote ARU Device Configuration change.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: ARU Device configuration change."
|
|
--#SUMMARY "ARU device configuration change."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 228
|
|
|
|
rmPDUCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communication Lost.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC RM PDU: Communication Lost."
|
|
--#SUMMARY "Communication Lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 229
|
|
|
|
emsCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communication Established.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC EMS: Communication Established."
|
|
--#SUMMARY "Communication Established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 230
|
|
|
|
emsCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communication Lost.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC EMS: Communication Lost."
|
|
--#SUMMARY "Communication Lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 231
|
|
|
|
emsProbeConnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A probe has been connected to the EMS.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the probe number.
|
|
The fourth argument is the probe name."
|
|
--#TYPE "APC EMS: Probe Connected."
|
|
--#SUMMARY "Probe Connected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 232
|
|
|
|
emsProbeDisconnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A probe has been disconnected from the EMS.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the probe number.
|
|
The fourth argument is the probe name."
|
|
--#TYPE "APC EMS: Probe Disconnected."
|
|
--#SUMMARY "Probe Disconnected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 233
|
|
|
|
emsSensorConnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A sensor has been connected to the EMS.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the sensor number.
|
|
The fourth argument is the sensor name."
|
|
--#TYPE "APC EMS: Sensor Connected."
|
|
--#SUMMARY "Sensor Connected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 234
|
|
|
|
emsSensorDisconnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A sensor has been disconnected from the EMS.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the sensor number.
|
|
The fourth argument is the sensor name."
|
|
--#TYPE "APC EMS: Sensor Disconnected."
|
|
--#SUMMARY "Sensor Disconnected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 235
|
|
|
|
emsSensorFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A EMS sensor is in the fault condition.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the sensor number.
|
|
The fourth argument is the sensor name."
|
|
--#TYPE "APC EMS: Sensor Fault."
|
|
--#SUMMARY "Sensor Fault."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 236
|
|
|
|
emsSensorFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A EMS sensor fault condition has cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the sensor number.
|
|
The fourth argument is the sensor name."
|
|
--#TYPE "APC EMS: Sensor Fault Cleared."
|
|
--#SUMMARY "Sensor Fault Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 237
|
|
|
|
emsBeaconConnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A beacon has been connected to the EMS.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC EMS: Beacon Connected."
|
|
--#SUMMARY "Beacon Connected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 238
|
|
|
|
emsBeaconDisconnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A beacon has been disconnected from the EMS.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC EMS: Beacon Disconnected."
|
|
--#SUMMARY "Beacon Disconnected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 239
|
|
|
|
emsBeaconOn TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A EMS beacon has gone on.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC EMS: Beacon On."
|
|
--#SUMMARY "Beacon On."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 240
|
|
|
|
emsBeaconOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A EMS beacon has gone off.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC EMS: Beacon Off."
|
|
--#SUMMARY "Beacon Off."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 241
|
|
|
|
emsMajorAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A Major Alarm is present in the EMS.
|
|
The first argument is the EMS serial number.
|
|
The second argument is the EMS name."
|
|
--#TYPE "APC EMS: Major Alarm."
|
|
--#SUMMARY "Major Alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 242
|
|
|
|
emsMajorAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Major Alarm condition has been cleared in the EMS.
|
|
The first argument is the EMS serial number.
|
|
The second argument is the EMS name."
|
|
--#TYPE "APC EMS: Major Alarm Cleared."
|
|
--#SUMMARY "Major Alarm Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 243
|
|
|
|
emsMinorAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A Minor Alarm is present in the EMS.
|
|
The first argument is the EMS serial number.
|
|
The second argument is the EMS name."
|
|
--#TYPE "APC EMS: Minor Alarm."
|
|
--#SUMMARY "Minor Alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 244
|
|
|
|
emsMinorAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Minor Alarm condition has been cleared in the EMS.
|
|
The first argument is the EMS serial number.
|
|
The second argument is the EMS name."
|
|
--#TYPE "APC EMS: Minor Alarm Cleared."
|
|
--#SUMMARY "Minor Alarm Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 245
|
|
|
|
emsOutletStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutletStatusOutletIndex, emsOutletStatusOutletName,
|
|
emsOutletStatusOutletState, emsOutletStatusOutletNormalState, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An outlet on the EMS has changed to its abnormal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the outlet number.
|
|
The fourth argument is the outlet name.
|
|
The fifth argument is the current outlet state (1=ON, 2=OFF).
|
|
The sixth argument is the configured normal outlet state (1=ON, 2=OFF)."
|
|
--#TYPE "APC EMS: Outlet has changed to its abnormal state."
|
|
--#SUMMARY "Outlet has changed to its abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 246
|
|
|
|
emsOutletStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutletStatusOutletIndex, emsOutletStatusOutletName,
|
|
emsOutletStatusOutletState, emsOutletStatusOutletNormalState, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on the EMS has changed to its normal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the outlet number.
|
|
The fourth argument is the outlet name.
|
|
The fifth argument is the current outlet state (1=ON, 2=OFF).
|
|
The sixth argument is the configured normal outlet state (1=ON, 2=OFF)."
|
|
--#TYPE "APC EMS: Outlet has changed to its normal state."
|
|
--#SUMMARY "Outlet has changed to its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 247
|
|
|
|
emsInputContactStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsInputContactStatusInputContactIndex,
|
|
emsInputContactStatusInputContactName, emsInputContactStatusInputContactState,
|
|
emsInputContactStatusInputContactNormalState, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An input contact on the EMS has changed to its abnormal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the input contact number.
|
|
The fourth argument is the input contact name.
|
|
The fifth argument is the input contact state (1=CLOSED, 2=OPEN).
|
|
The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC EMS: Input contact has changed to its abnormal state."
|
|
--#SUMMARY "Input contact has changed to its abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 248
|
|
|
|
emsInputContactStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsInputContactStatusInputContactIndex,
|
|
emsInputContactStatusInputContactName, emsInputContactStatusInputContactState,
|
|
emsInputContactStatusInputContactNormalState, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An input contact on the EMS has changed to its normal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the input contact number.
|
|
The fourth argument is the input contact name.
|
|
The fifth argument is the input contact state (1=CLOSED, 2=OPEN).
|
|
The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC EMS: Input contact has changed to its normal state."
|
|
--#SUMMARY "Input contact has changed to its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 249
|
|
|
|
emsOutputRelayStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutputRelayStatusOutputRelayIndex,
|
|
emsOutputRelayStatusOutputRelayName, emsOutputRelayStatusOutputRelayState,
|
|
emsOutputRelayStatusOutputRelayNormalState, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An output relay on the EMS has changed to its abnormal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the output relay number.
|
|
The fourth argument is the output relay name.
|
|
The fifth argument is the current output relay state (1=CLOSED, 2=OPEN).
|
|
The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC EMS: Output Relay has changed to its abnormal state."
|
|
--#SUMMARY "Output Relay has changed to its abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 250
|
|
|
|
emsOutputRelayStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutputRelayStatusOutputRelayIndex,
|
|
emsOutputRelayStatusOutputRelayName, emsOutputRelayStatusOutputRelayState,
|
|
emsOutputRelayStatusOutputRelayNormalState, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An output relay on the EMS has changed to its normal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the output relay number.
|
|
The fourth argument is the output relay name.
|
|
The fifth argument is the current output relay state (1=CLOSED, 2=OPEN).
|
|
The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC EMS: Output Relay has changed to its normal state."
|
|
--#SUMMARY "Output Relay has changed to its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 251
|
|
|
|
emsDeviceConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A device configuration change has been made on the EMS.
|
|
The first argument is the EMS serial number.
|
|
The second argument is the EMS name."
|
|
--#TYPE "APC: A device configuration change on a EMS."
|
|
--#SUMMARY "A device configuration change has been made on a EMS."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 252
|
|
|
|
envHighTempThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: High temperature threshold violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: High temperature threshold violation."
|
|
--#SUMMARY "High temperature threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 253
|
|
|
|
envHighTempThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: High temperature threshold violation cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: High temperature threshold violation cleared."
|
|
--#SUMMARY "High temperature threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 254
|
|
|
|
envLowTempThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Low temperature threshold violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Low temperature threshold violation."
|
|
--#SUMMARY "Low temperature threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 255
|
|
|
|
envLowTempThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Low temperature threshold violation cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Low temperature threshold violation cleared."
|
|
--#SUMMARY "Low temperature threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 256
|
|
|
|
envHighHumidityThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: High humidity threshold violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current humidity
|
|
The fourth argument is the probe number.
|
|
The fifth argument is the probe name."
|
|
--#TYPE "APC ENV: High humidity threshold violation."
|
|
--#SUMMARY "High humidity threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 257
|
|
|
|
envHighHumidityThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: High humidity threshold violation cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current humidity.
|
|
The fourth argument is the probe number.
|
|
The fifth argument is the probe name."
|
|
--#TYPE "APC ENV: High humidity threshold violation cleared."
|
|
--#SUMMARY "High humidity threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 258
|
|
|
|
envLowHumidityThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Low humidity threshold violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current humidity
|
|
The fourth argument is the probe number.
|
|
The fifth argument is the probe name."
|
|
--#TYPE "APC ENV: Low humidity threshold violation."
|
|
--#SUMMARY "Low humidity threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 259
|
|
|
|
envLowHumidityThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Low humidity threshold violation cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current humidity.
|
|
The fourth argument is the probe number.
|
|
The fifth argument is the probe name."
|
|
--#TYPE "APC ENV: Low humidity threshold violation cleared."
|
|
--#SUMMARY "Low humidity threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 260
|
|
|
|
|
|
-- Switched and Metered Rack PDU Traps
|
|
|
|
rPDUCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communication with a Rack PDU has been established.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC Rack PDU: Communication established."
|
|
--#SUMMARY "Communication with a Rack PDU established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 266
|
|
|
|
rPDUCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communication with a Rack PDU has been lost.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC Rack PDU: Communication lost."
|
|
--#SUMMARY "Communication with a Rack PDU has been lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 267
|
|
|
|
rPDUOutletOn TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDUOutletControlIndex, rPDUOutletControlOutletName,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on a Switched Rack PDU has turned on.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "APC Switched Rack PDU: An outlet has turned on."
|
|
--#SUMMARY "An outlet on a Switched Rack PDU has turned on."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 268
|
|
|
|
rPDUOutletOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDUOutletControlIndex, rPDUOutletControlOutletName,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on a Switched Rack PDU has turned off.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "APC Switched Rack PDU: An outlet has turned off."
|
|
--#SUMMARY "An outlet on a Switched Rack PDU has turned off."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 269
|
|
|
|
rPDUDeviceConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A device configuration change has been made on a
|
|
Rack PDU.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC Rack PDU: Device configuration change made."
|
|
--#SUMMARY "Device configuration change has been made on a Rack PDU."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 270
|
|
|
|
rPDUOutletConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDUOutletControlIndex, rPDUOutletControlOutletName,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet configuration change has been made on a
|
|
Switched Rack PDU.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "APC Switched Rack PDU: Outlet configuration change made."
|
|
--#SUMMARY "Outlet configuration change has been made on a Switched Rack PDU."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 271
|
|
|
|
rPDULowLoad TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Rack PDU has violated the low load threshold.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC Rack PDU: Violation of low load threshold."
|
|
--#SUMMARY "A Rack PDU has violated the low load threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 272
|
|
|
|
rPDULowLoadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The low load condition on a Rack PDU has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC Rack PDU: Low load condition cleared."
|
|
--#SUMMARY "The low load condition on a Rack PDU has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 273
|
|
|
|
rPDUNearOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Rack PDU is near an overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC Rack PDU: Near an overload condition."
|
|
--#SUMMARY "A Rack PDU is near an overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 274
|
|
|
|
rPDUNearOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The near overload condition on a Rack PDU has
|
|
been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC Rack PDU: Near overload condition has cleared."
|
|
--#SUMMARY "Rack PDU near overload condition has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 275
|
|
|
|
rPDUOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A Rack PDU is in an overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC Rack PDU: Overload condition."
|
|
--#SUMMARY "A Rack PDU is in an overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 276
|
|
|
|
rPDUOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadStatusPhaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The overload condition on a Rack PDU has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "APC Rack PDU: Overload condition has cleared."
|
|
--#SUMMARY "The overload condition on a Rack PDU has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 277
|
|
|
|
rPDUPowerSupply1Fail TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Power Supply 1 on Rack PDU is in FAIL state.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC Rack PDU: Power Supply 1 is in FAIL state."
|
|
--#SUMMARY "Power Supply 1 on Rack PDU is in FAIL state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 278
|
|
|
|
rPDUPowerSupply1Ok TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Power Supply 1 on Rack PDU is operating normally.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC Rack PDU: Power Supply 1 is operating normally."
|
|
--#SUMMARY "Power Supply 1 on Rack PDU is operating normally."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 279
|
|
|
|
rPDUPowerSupply2Fail TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Power Supply 2 on Rack PDU is in FAIL state.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC Rack PDU: Power Supply 2 is in FAIL state."
|
|
--#SUMMARY "Power Supply 2 on Rack PDU is in FAIL state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 280
|
|
|
|
rPDUPowerSupply2Ok TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Power Supply 2 on Rack PDU is operating normally.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "APC Rack PDU: Power Supply 2 is operating normally."
|
|
--#SUMMARY "Power Supply 2 on Rack PDU is operating normally."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 281
|
|
|
|
rPDUPhaseConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDULoadPhaseConfigIndex, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A phase configuration change has been made on a
|
|
Rack PDU.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase index number."
|
|
--#TYPE "APC Rack PDU: Phase configuration change made."
|
|
--#SUMMARY "Phase configuration change has been made on a Rack PDU."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 282
|
|
|
|
rPDUCancelPendingCommand TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDUOutletControlIndex, rPDUOutletControlOutletName,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A cancel pending command has been made on a
|
|
Switched Rack PDU.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number (0 indicates all outlets).
|
|
The fourth argument is the outlet name (or device name if all outlets)."
|
|
--#TYPE "APC Switched Rack PDU: Cancel Pending Command made."
|
|
--#SUMMARY "A Cancel Pending Command has been made on a Switched Rack PDU."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 283
|
|
|
|
aruAlinkCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Remote ARU Communication Established.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: Communication Established."
|
|
--#SUMMARY "Communication Established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 284
|
|
|
|
aruAlinkCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Remote ARU Communication Lost.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: Communication Lost."
|
|
--#SUMMARY "Communication Lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 285
|
|
|
|
aruFanFail TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Remote ARU Fan Fail.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: Fan Failure."
|
|
--#SUMMARY "Fan Fail."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 286
|
|
|
|
aruFanFailCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Remote ARU Fan Fail Cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: Fan Fail Cleared."
|
|
--#SUMMARY "Fan Fail Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 287
|
|
|
|
aruSmokeAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Remote ARU Smoke Alarm.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: Smoke Alarm."
|
|
--#SUMMARY "Smoke Alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 288
|
|
|
|
aruSmokeAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Remote ARU Smoke Alarm Cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: Smoke Alarm Cleared."
|
|
--#SUMMARY "Smoke Alarm Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 289
|
|
|
|
aruHighTemperatureAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: ARU Exhaust temperature has exceeded the override
|
|
threshold and the ARU has increased fan speed to
|
|
maintain a safe environment in the rack.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: High Temperature Alarm."
|
|
--#SUMMARY "High Temperature Alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 290
|
|
|
|
aruHighTemperatureAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: ARU temperature override state has been cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: High Temperature Alarm Cleared."
|
|
--#SUMMARY "High Temperature Alarm Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 291
|
|
|
|
aruExhaustTemperatureAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: ARU Extreme Exhaust Temperature Alarm.
|
|
The ARU is unable to control the temperature within the rack
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: Exhaust Temperature Alarm."
|
|
--#SUMMARY "Exhaust Temperature Alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 292
|
|
|
|
aruExhaustTemperatureAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Remote ARU Exhaust Temperature Alarm Cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: Exhaust Temperature Alarm Cleared."
|
|
--#SUMMARY "Exhaust Temperature Alarm Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 293
|
|
|
|
envAlinkCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Remote Probe Communication Established.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the probe number.
|
|
The fourth argument is the probe name."
|
|
--#TYPE "APC ENV: Communication Established."
|
|
--#SUMMARY "Communication Established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 294
|
|
|
|
envAlinkCommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Remote Probe Communication Lost.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the probe number.
|
|
The fourth argument is the probe name."
|
|
--#TYPE "APC ENV: Communication Lost."
|
|
--#SUMMARY "Communication Lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 295
|
|
|
|
emsAlinkPowerOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Alink Power Overload.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC EMS: Alink Power Overload."
|
|
--#SUMMARY "Alink Power Overload."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 296
|
|
|
|
emsAlinkPowerOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Alink Power Overload Cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC EMS: Alink Power Overload Cleared."
|
|
--#SUMMARY "Alink Power Overload Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 297
|
|
|
|
upsOutletGroupTurnedOn TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { upsOutletGroupControlIndex, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The specified Outlet Group turned on."
|
|
--#TYPE "APC UPS: Outlet Group turned on."
|
|
--#SUMMARY "Outlet Group turned on"
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 298
|
|
|
|
upsOutletGroupTurnedOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { upsOutletGroupControlIndex, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The specified Outlet Group turned off."
|
|
--#TYPE "APC UPS: Outlet Group turned off."
|
|
--#SUMMARY "Outlet Group turned off."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 299
|
|
|
|
smwCriticalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsGauge, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A Symmetra MW UPS critical condition has been detected.
|
|
The first variable is the fault condition."
|
|
--#TYPE "APC Symmetra MW UPS: A critical condition has been detected."
|
|
--#SUMMARY "A critical condition has been detected."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 300
|
|
|
|
smwCriticalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsGauge, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Symmetra MW UPS critical condition has been cleared.
|
|
The first variable is the fault condition."
|
|
--#TYPE "APC Symmetra MW UPS: A critical condition has been cleared."
|
|
--#SUMMARY "A critical condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 301
|
|
|
|
smwWarningCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsGauge, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Symmetra MW UPS warning condition has been detected.
|
|
The first variable is the fault condition."
|
|
--#TYPE "APC Symmetra MW UPS: A warning condition has been detected."
|
|
--#SUMMARY "A warning condition has been detected."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 302
|
|
|
|
smwWarningConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsGauge, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Symmetra MW UPS warning condition has been cleared.
|
|
The first variable is the fault condition."
|
|
--#TYPE "APC Symmetra MW UPS: A warning condition has been cleared."
|
|
--#SUMMARY "A warning condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 303
|
|
|
|
smwInformationalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsGauge, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Symmetra MW UPS informational condition has been detected.
|
|
The first variable is the fault condition."
|
|
--#TYPE "APC Symmetra MW UPS: Informational condition detected."
|
|
--#SUMMARY "An informational condition has been detected."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 304
|
|
|
|
smwInformationalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsGauge, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Symmetra MW UPS informational condition has been cleared.
|
|
The first variable is the fault condition."
|
|
--#TYPE "APC Symmetra MW UPS: Informational condition cleared."
|
|
--#SUMMARY "An informational condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 305
|
|
|
|
airCriticalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: An Air critical condition was detected.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC Air: A critical condition was detected. "
|
|
--#SUMMARY "A critical condition was detected. "
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 306
|
|
|
|
airCriticalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An Air critical condition was cleared.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC Air: A critical condition was cleared. "
|
|
--#SUMMARY "A critical condition was cleared. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 307
|
|
|
|
airWarningCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An Air warning condition was detected.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC Air: A warning condition was detected. "
|
|
--#SUMMARY "A warning condition was detected. "
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 308
|
|
|
|
airWarningConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An Air warning condition was cleared.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC Air: A warning condition was cleared. "
|
|
--#SUMMARY "A warning condition was cleared. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 309
|
|
|
|
airInformationalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An Air informational condition was detected.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC Air: Informational condition detected. "
|
|
--#SUMMARY "An informational condition was detected. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 310
|
|
|
|
airInformationalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An Air informational condition was cleared.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC Air: Informational condition was cleared. "
|
|
--#SUMMARY "An informational condition was cleared. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 311
|
|
|
|
-- xPDU Traps (part 1)
|
|
|
|
xPDUInputVoltageLowAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Three-phase input voltage to the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
|
|
The fourth argument is the measured voltage in tenths of Volts.
|
|
The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated."
|
|
--#TYPE "APC XPDU: Main input low voltage alarm."
|
|
--#SUMMARY "Input voltage is below threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 312
|
|
|
|
xPDUInputVoltageLowAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
|
|
The fourth argument is the measured voltage in tenths of Volts."
|
|
--#TYPE "APC XPDU: Main input low voltage alarm cleared."
|
|
--#SUMMARY "Main input low voltage cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 313
|
|
|
|
|
|
xPDUInputVoltageHighAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Three-phase input voltage to the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
|
|
The fourth argument is the measured voltage in tenths of Volts.
|
|
The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated."
|
|
--#TYPE "APC XPDU: Main input high voltage alarm."
|
|
--#SUMMARY "Main input voltage is above threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 314
|
|
|
|
xPDUInputVoltageHighAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
|
|
The fourth argument is the measured voltage in tenths of Volts."
|
|
--#TYPE "APC XPDU: Main input high voltage alarm cleared."
|
|
--#SUMMARY "Main input high voltage alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 315
|
|
|
|
xPDUBypassVoltageLowAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Three-phase bypass input voltage to the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
|
|
The fourth argument is the measured voltage in tenths of Volts.
|
|
The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated."
|
|
--#TYPE "APC XPDU: Bypass input low voltage alarm."
|
|
--#SUMMARY "Bypass input voltage is below threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 316
|
|
|
|
xPDUBypassVoltageLowAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
|
|
The fourth argument is the measured voltage in tenths of Volts."
|
|
--#TYPE "APC XPDU: Bypass input low voltage alarm cleared."
|
|
--#SUMMARY "Bypass input low voltage alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 317
|
|
|
|
xPDUBypassVoltageHighAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Three-phase bypass input voltage to the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
|
|
The fourth argument is the measured voltage in tenths of Volts.
|
|
The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated."
|
|
--#TYPE "APC XPDU: Bypass input high voltage alarm."
|
|
--#SUMMARY "Bypass input voltage is above threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 318
|
|
|
|
xPDUBypassVoltageHighAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
|
|
The fourth argument is the measured voltage in tenths of Volts."
|
|
--#TYPE "APC XPDU: Bypass input high voltage alarm cleared."
|
|
--#SUMMARY "Bypass input voltage alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 319
|
|
|
|
xPDUOutputVoltageLowAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The three-phase output voltage of the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
|
|
The fourth argument is the measured voltage in tenths of Volts.
|
|
The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated."
|
|
--#TYPE "APC XPDU: Output low voltage alarm."
|
|
--#SUMMARY "Output voltage is below threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 320
|
|
|
|
xPDUOutputVoltageLowAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
|
|
The fourth argument is the measured voltage in tenths of Volts."
|
|
--#TYPE "APC XPDU: Output low voltage alarm cleared."
|
|
--#SUMMARY "Output low voltage alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 321
|
|
|
|
xPDUOutputVoltageHighAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The three-phase output voltage of the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
|
|
The fourth argument is the measured voltage in tenths of Volts.
|
|
The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated."
|
|
--#TYPE "APC XPDU: Output high voltage alarm."
|
|
--#SUMMARY "Output voltage is above threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 322
|
|
|
|
xPDUOutputVoltageHighAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
|
|
The fourth argument is the measured voltage in tenths of Volts."
|
|
--#TYPE "APC XPDU: Output high voltage alarm cleared."
|
|
--#SUMMARY "Output high voltage alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 323
|
|
|
|
xPDUOutputCurrentLowAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The three-phase output load current of the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the measured current in tenths of Amps.
|
|
The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated."
|
|
--#TYPE "APC XPDU: Output low current alarm."
|
|
--#SUMMARY "Output current is below threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 324
|
|
|
|
xPDUOutputCurrentLowAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The three-phase output load current of the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the measured current in tenths of Amps."
|
|
--#TYPE "APC XPDU: Output low current alarm cleared."
|
|
--#SUMMARY "Output low current alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 325
|
|
|
|
xPDUOutputCurrentHighAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The three-phase load current of the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the measured current in tenths of Amps.
|
|
The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated."
|
|
--#TYPE "APC XPDU: Output high current alarm."
|
|
--#SUMMARY "Output current is above threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 326
|
|
|
|
xPDUOutputCurrentHighAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The three-phase output current of the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the measured current in tenths of Amps."
|
|
--#TYPE "APC XPDU: Output high current alarm cleared."
|
|
--#SUMMARY "Output high current alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 327
|
|
|
|
xPDUOutputFrequencyAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The devices output frequency is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the frequency deviation from the nominal in tenths of Hertz."
|
|
--#TYPE "APC XPDU: Output frequency out-of-range alarm."
|
|
--#SUMMARY "Output frequency is out-of-range."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 328
|
|
|
|
xPDUOutputFrequencyAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The devices output frequency is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: Output frequency back in range."
|
|
--#SUMMARY "Output frequency in range."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 329
|
|
|
|
xPDUSystemGroundCurrentAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The earth ground current of the device is over the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the measured current in tenths of Amps.
|
|
The fourth argument is the threshold, in tenths of Amps, above which the alarm was generated."
|
|
--#TYPE "APC XPDU: Earth ground high current alarm."
|
|
--#SUMMARY "Earth ground current is above threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 330
|
|
|
|
xPDUSystemGroundCurrentAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The earth ground current of the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the measured current in tenths of Amps."
|
|
--#TYPE "APC XPDU: Earth ground high current alarm cleared."
|
|
--#SUMMARY "Earth ground high current alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 331
|
|
|
|
xPDUInputContactStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A user input contact on the device has changed to its abnormal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the input contact number.
|
|
The fourth argument is the input contact name.
|
|
The fifth argument is the input contact state (1=OPEN, 2=CLOSED).
|
|
The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)."
|
|
--#TYPE "APC XPDU: Input contact has changed to its abnormal state."
|
|
--#SUMMARY "Input contact has changed to its abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 332
|
|
|
|
xPDUInputContactStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A user input contact on the device has changed to its normal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the input contact number.
|
|
The fourth argument is the input contact name.
|
|
The fifth argument is the input contact state (1=CLOSED, 2=OPEN).
|
|
The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)."
|
|
--#TYPE "APC XPDU: Input contact has changed to its normal state."
|
|
--#SUMMARY "Input contact has changed to its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 333
|
|
|
|
xPDUOutputNeutralCurrentHighAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The three-phase neutral current of the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the measured current in tenths of Amps.
|
|
The fourth argument is the threshold, in tenths of Amps, above which the alarm was generated."
|
|
--#TYPE "APC XPDU: Output high neutral current alarm."
|
|
--#SUMMARY "Output neutral current is above threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 334
|
|
|
|
xPDUOutputNeutralCurrentHighAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The output neutral current of the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the measured current in tenths of Amps."
|
|
--#TYPE "APC XPDU: Output neutral high current alarm cleared."
|
|
--#SUMMARY "Output neutral high current alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 335
|
|
|
|
xPDUCoolingFanAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The device's internal cooling fans have failed.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: Cooling fan failure alarm."
|
|
--#SUMMARY "Cooling fan failure."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 336
|
|
|
|
xPDUCoolingFanAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The device's cooling fans are now functioning properly.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: Cooling fan alarm cleared."
|
|
--#SUMMARY "Cooling fan alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 337
|
|
|
|
xPDUTransformerTempAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The device's isolation transformer is over temperature.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: Isolation transformer over temperature alarm."
|
|
--#SUMMARY "Transformer temp alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 338
|
|
|
|
xPDUTransformerTempAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The device's isolation transformer is no longer over temperature.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: Isolation transformer over temperature alarm cleared."
|
|
--#SUMMARY "Transformer temp alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 339
|
|
|
|
xPDUBranchCurrentLowAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The current in a branch circuit is outside the limits specified for that
|
|
branch circuit.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the panel position of the branch circuit (1-based index).
|
|
The fourth argument is the measured current in tenths of Amps.
|
|
The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated."
|
|
--#TYPE "APC XPDU: Branch circuit low current alarm."
|
|
--#SUMMARY "Branch circuit current is below threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 340
|
|
|
|
xPDUBranchCurrentLowAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a branch circuit is back within the limits
|
|
specified for that branch circuit.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the panel position of the branch circuit (1-based index).
|
|
The fourth argument is the measured current in tenths of Amps."
|
|
--#TYPE "APC XPDU: Branch circuit low current alarm cleared."
|
|
--#SUMMARY "Branch circuit low current alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 341
|
|
|
|
xPDUBranchCurrentHighAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The current in a branch circuit is outside the limits specified for that
|
|
branch circuit.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the panel position of the branch circuit (1-based index).
|
|
The fourth argument is the measured current in tenths of Amps.
|
|
The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated."
|
|
--#TYPE "APC XPDU: Branch circuit high current alarm."
|
|
--#SUMMARY "Branch circuit current is above threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 342
|
|
|
|
xPDUBranchCurrentHighAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a branch circuit is back within the limits
|
|
specified for that branch circuit.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the panel position of the branch circuit (1-based index).
|
|
The fourth argument is the measured current in tenths of Amps."
|
|
--#TYPE "APC XPDU: Branch circuit high current alarm cleared."
|
|
--#SUMMARY "Branch circuit high current alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 343
|
|
|
|
|
|
xPDUInternalCommError TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: There is an internal communication error in the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: Internal communication error."
|
|
--#SUMMARY "Internal communication error."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 344
|
|
|
|
emsHardwareStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The device's hardware is improperly configured and operating outside
|
|
normal bounds for the hardware. This can be caused by improper devices being
|
|
connected to the EMS ports or Alink Current limit detection."
|
|
--#TYPE "APC EMS: Hardware is in an abnormal state."
|
|
--#SUMMARY "Hardware is in an abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 345
|
|
|
|
emsHardwareStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The device's hardware is in its normal operational state.
|
|
The first argument is the host device serial number."
|
|
--#TYPE "APC EMS: Hardware is in a normal state."
|
|
--#SUMMARY "Hardware is in its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 346
|
|
|
|
ceSevereCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A Custom Event severe condition was detected.
|
|
The first variable is the custom event text message.
|
|
The second variable is the custom event number."
|
|
--#TYPE "APC Custom Event: A severe condition was detected. "
|
|
--#SUMMARY "A severe condition was detected. "
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 347
|
|
|
|
ceSevereConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Custom Event severe condition was cleared.
|
|
The first variable is the custom event text message.
|
|
The second variable is the custom event number."
|
|
--#TYPE "APC Custom Event: A severe condition was cleared. "
|
|
--#SUMMARY "A severe condition was cleared. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 348
|
|
|
|
ceWarningCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Custom Event warning condition was detected.
|
|
The first variable is the custom event text message.
|
|
The second variable is the custom event number."
|
|
--#TYPE "APC Custom Event: A warning condition was detected. "
|
|
--#SUMMARY "A warning condition was detected. "
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 349
|
|
|
|
ceWarningConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Custom Event warning condition was cleared.
|
|
The first variable is the custom event text message.
|
|
The second variable is the custom event number."
|
|
--#TYPE "APC Custom Event: A warning condition was cleared. "
|
|
--#SUMMARY "A warning condition was cleared. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 350
|
|
|
|
ceInformationalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Custom Event informational condition was detected.
|
|
The first variable is the custom event text message.
|
|
The second variable is the custom event number."
|
|
--#TYPE "APC Custom Event: Informational condition detected. "
|
|
--#SUMMARY "An informational condition was detected. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 351
|
|
|
|
ceInformationalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Custom Event informational condition was cleared.
|
|
The first variable is the custom event text message.
|
|
The second variable is the custom event number."
|
|
--#TYPE "APC Custom Event: Informational condition was cleared. "
|
|
--#SUMMARY "An informational condition was cleared. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 352
|
|
|
|
upsInternalOverTemperature TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The internal over temperature condition exists."
|
|
--#TYPE "APC UPS: The internal over temperature condition exists."
|
|
--#SUMMARY "The internal over temperature condition exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 353
|
|
|
|
upsInternalOverTemperatureCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The internal over temperature condition cleared."
|
|
--#TYPE "APC UPS: The internal over temperature condition cleared."
|
|
--#SUMMARY "The internal over temperature condition cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 354
|
|
|
|
upsMpuReset TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The MPU has been reset."
|
|
--#TYPE "APC UPS: The MPU has been reset."
|
|
--#SUMMARY "The MPU has been reset."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 355
|
|
|
|
upsOutputSwitchClosed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The Output Switch is closed."
|
|
--#TYPE "APC UPS: The Output Switch is closed."
|
|
--#SUMMARY "The Output Switch is closed."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 356
|
|
|
|
upsOutputSwitchOpened TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The Output Switch is open."
|
|
--#TYPE "APC UPS: The Output Switch is open."
|
|
--#SUMMARY "The Output Switch is open."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 357
|
|
|
|
upsCalibrationStackChanged TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A calibration value in the stack was changed."
|
|
--#TYPE "APC UPS: A calibration value in the stack was changed."
|
|
--#SUMMARY "A calibration value in the stack was changed."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 358
|
|
|
|
|
|
-- Upgraded EMS now has more env traps
|
|
|
|
envMaxTempThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Max temperature threshold violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Max temperature threshold violation."
|
|
--#SUMMARY "Max temperature threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 359
|
|
|
|
envMaxTempThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Max temperature threshold violation cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Max temperature threshold violation cleared."
|
|
--#SUMMARY "Max temperature threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 360
|
|
|
|
envMinTempThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Min temperature threshold violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Min temperature threshold violation."
|
|
--#SUMMARY "Min temperature threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 361
|
|
|
|
envMinTempThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Min temperature threshold violation cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Min temperature threshold violation cleared."
|
|
--#SUMMARY "Min temperature threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 362
|
|
|
|
envMaxHumidityThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Max humidity threshold violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current humidity
|
|
The fourth argument is the probe number.
|
|
The fifth argument is the probe name."
|
|
--#TYPE "APC ENV: Max humidity threshold violation."
|
|
--#SUMMARY "Max humidity threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 363
|
|
|
|
envMaxHumidityThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Max humidity threshold violation cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current humidity.
|
|
The fourth argument is the probe number.
|
|
The fifth argument is the probe name."
|
|
--#TYPE "APC ENV: Max humidity threshold violation cleared."
|
|
--#SUMMARY "Max humidity threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 364
|
|
|
|
envMinHumidityThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Min humidity threshold violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current humidity
|
|
The fourth argument is the probe number.
|
|
The fifth argument is the probe name."
|
|
--#TYPE "APC ENV: Min humidity threshold violation."
|
|
--#SUMMARY "Min humidity threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 365
|
|
|
|
envMinHumidityThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Min humidity threshold violation cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current humidity.
|
|
The fourth argument is the probe number.
|
|
The fifth argument is the probe name."
|
|
--#TYPE "APC ENV: Min humidity threshold violation cleared."
|
|
--#SUMMARY "Min humidity threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 366
|
|
|
|
envSTIncTempRateViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Short-term increasing temperature rate violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Short-term inc. temp rate violation."
|
|
--#SUMMARY "Short-term inc. temp rate violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 367
|
|
|
|
envSTIncTempRateViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Short-term increasing temperature rate cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Short-term inc. temp rate violation cleared."
|
|
--#SUMMARY "Short-term inc. temp rate violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 368
|
|
|
|
envSTDecTempRateViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Short-term decreasing temperature rate violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Short-term dec. temp rate violation."
|
|
--#SUMMARY "Short-term dec. temp rate violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 369
|
|
|
|
envSTDecTempRateViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Short-term decreasing temperature rate cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Short-term dec. temp rate violation cleared."
|
|
--#SUMMARY "Short-term dec. temp rate violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 370
|
|
|
|
envLTIncTempRateViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Long-term increasing temperature rate violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Long-term inc. temp rate violation."
|
|
--#SUMMARY "Long-term inc. temp rate violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 371
|
|
|
|
envLTIncTempRateViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Long-term increasing temperature rate cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Long-term inc. temp rate violation cleared."
|
|
--#SUMMARY "Long-term inc. temp rate violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 372
|
|
|
|
envLTDecTempRateViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Long-term decreasing temperature rate violated on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Long-term dec. temp rate violation."
|
|
--#SUMMARY "Long-term dec. temp rate violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 373
|
|
|
|
envLTDecTempRateViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
|
|
emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Long-term decreasing temperature rate cleared on the probe.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the current temperature.
|
|
The fourth argument is the temperature scale.
|
|
The fifth argument is the probe number.
|
|
The sixth argument is the probe name."
|
|
--#TYPE "APC ENV: Long-term dec. temp rate violation cleared."
|
|
--#SUMMARY "Long-term dec. temp rate violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 374
|
|
|
|
-- Battery Management System Traps
|
|
|
|
bmsCriticalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A Battery Management System critical condition was detected.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC BMS: A critical condition was detected. "
|
|
--#SUMMARY "A critical condition was detected. "
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 375
|
|
|
|
bmsCriticalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Battery Management System critical condition was cleared.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC BMS: A critical condition was cleared. "
|
|
--#SUMMARY "A critical condition was cleared. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 376
|
|
|
|
bmsWarningCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Battery Management System warning condition was detected.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC BMS: A warning condition was detected. "
|
|
--#SUMMARY "A warning condition was detected. "
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 377
|
|
|
|
bmsWarningConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Battery Management System warning condition was cleared.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC BMS: A warning condition was cleared. "
|
|
--#SUMMARY "A warning condition was cleared. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 378
|
|
|
|
bmsInformationalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Battery Management System informational condition was detected.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC BMS: Informational condition detected. "
|
|
--#SUMMARY "An informational condition was detected. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 379
|
|
|
|
bmsInformationalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A Battery Management System informational condition was cleared.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "APC BMS: Informational condition was cleared. "
|
|
--#SUMMARY "An informational condition was cleared. "
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 380
|
|
|
|
-- xATS Traps
|
|
|
|
xATSOutputVoltageLowAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The device three-phase output voltage of the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
|
|
The fourth argument is the measured voltage in tenths of Volts.
|
|
The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated."
|
|
--#TYPE "APC XATS: Output low voltage alarm."
|
|
--#SUMMARY "Output voltage is below threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 381
|
|
|
|
xATSOutputVoltageLowAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The devices three-phase output voltage is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
|
|
The fourth argument is the measured voltage in tenths of Volts."
|
|
--#TYPE "APC XATS: Output low voltage alarm cleared."
|
|
--#SUMMARY "Output low voltage alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 382
|
|
|
|
xATSOutputVoltageHighAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The device three-phase output voltage of the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
|
|
The fourth argument is the measured voltage in tenths of Volts.
|
|
The fifth argument is the threshold, in tenths of Volts, above which the alarm is generated."
|
|
--#TYPE "APC XATS: Output high voltage alarm."
|
|
--#SUMMARY "Output voltage is above threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 383
|
|
|
|
xATSOutputVoltageHighAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The devices three-phase output voltage is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
|
|
The fourth argument is the measured voltage in tenths of Volts."
|
|
--#TYPE "APC XATS: Output high voltage alarm cleared."
|
|
--#SUMMARY "Output high voltage alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 384
|
|
|
|
xATSOutputCurrentLowAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The three-phase load current of the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the measured current in Amps.
|
|
The fifth argument is the threshold, in Amps, from which the alarm was generated."
|
|
--#TYPE "APC XATS: Output low current alarm."
|
|
--#SUMMARY "Output current is below threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 385
|
|
|
|
xATSOutputCurrentLowAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The three-phase load current of the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the measured current in Amps."
|
|
--#TYPE "APC XATS: Output low current alarm cleared."
|
|
--#SUMMARY "Output low current alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 386
|
|
|
|
xATSOutputCurrentHighAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The three-phase output load current of the device is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the measured current in Amps.
|
|
The fifth argument is the threshold, in Amps, from which the alarm was generated."
|
|
--#TYPE "APC XATS: Output high current alarm."
|
|
--#SUMMARY "Output current is above threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 387
|
|
|
|
xATSOutputCurrentHighAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The three-phase output load current of the device is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the measured current in Amps."
|
|
--#TYPE "APC XATS: Output high current alarm cleared."
|
|
--#SUMMARY "Output high current alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 388
|
|
|
|
|
|
xATSOutputFrequencyAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The devices output frequency is outside the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the frequency deviation from the nominal in tenths of Hertz.
|
|
The fourth argument is the frequency deviation threshold in tenths of Hertz,
|
|
from which the alarm was generated."
|
|
--#TYPE "APC XATS: Output frequency out-of-range alarm."
|
|
--#SUMMARY "Output frequency is out-of-range."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 389
|
|
|
|
xATSOutputFrequencyAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The devices output frequency is back within the specified limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Output frequency back in range."
|
|
--#SUMMARY "Output frequency in range."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 390
|
|
|
|
xATSInternalCommError TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: There is an internal communication error in the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Internal communication error."
|
|
--#SUMMARY "Internal communication error."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 391
|
|
|
|
xATSInternalCommErrorCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Internal communication has been restored.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Internal Communication error cleared."
|
|
--#SUMMARY "ATS Communication error cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 392
|
|
|
|
xATSDataCommMismatchError TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A data incompatibility exists within the device. This
|
|
is typically the result of mismatches between firmware revisions
|
|
of the transfer switch controller and the Network Management interface.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Data mismatch error."
|
|
--#SUMMARY "ATS data mismatch error."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 393
|
|
|
|
xATSDataCommMismatchErrorCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The internal data incompatibility has been resolved.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: data mismatch error cleared."
|
|
--#SUMMARY "ATS data mismatch error cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 394
|
|
|
|
xATSGenCommLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The XATS cannot communicate with the generator.
|
|
This will make unavailable all the xATSGenerator OIDs.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: No communication with generator."
|
|
--#SUMMARY "ATS/Generator communication lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 395
|
|
|
|
xATSGenCommEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The XATS has established communication with the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Communication with generator established."
|
|
--#SUMMARY "ATS/generator communication established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 396
|
|
|
|
xATSNeutralPosition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: XATS has transferred to neutral position.
|
|
In this position neither Source 1 nor Source 2 is selected,
|
|
and the XATS will have no output voltage.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the mode in which the switch is operating
|
|
(1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual)."
|
|
--#TYPE "APC XATS: Transferred to the neutral (no output power) position."
|
|
--#SUMMARY "Transferred to neutral."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 397
|
|
|
|
xATSSwitchTransferEvent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: XATS has transferred from one source to the other.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the mode in which the switch is operating.
|
|
(1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual).
|
|
The fourth argument is the input source selected (1=Source 1, 2=Source 2).
|
|
The fifth argument is type of transfer that took place. (1=Closed, 2=Open, 3=Unknown)"
|
|
--#TYPE "APC XATS: Transferred from Source-X to Source-Y."
|
|
--#SUMMARY "Source-to-Source transfer."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 398
|
|
|
|
xATSInternalATSFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: An internal XATS fault has been detected.
|
|
The XATS may have forced itself to not-in-auto mode (abnormal condition),
|
|
as indicated by the xATSSwitchStatusAutoSwitchOperationalMode OID.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument indicates the detected fault.
|
|
|
|
1=Cannot Close S1
|
|
2=Cannot Close S2
|
|
3=Cannot Open S1
|
|
4=Cannot Open S2
|
|
5=Cannot Trip Open S1
|
|
6=Cannot Trip Open S2
|
|
7=Start Contact Failure
|
|
8=Voltage Sensing Failure"
|
|
|
|
--#TYPE "APC XATS: Internal fault detected."
|
|
--#SUMMARY "ATS internal fault detected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 399
|
|
|
|
xATSInternalATSFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The detected internal XATS fault has been cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument indicates the detected fault.
|
|
|
|
1=Cannot Close S1
|
|
2=Cannot Close S2
|
|
3=Cannot Open S1
|
|
4=Cannot Open S2
|
|
5=Cannot Trip Open S1
|
|
6=Cannot Trip Open S2
|
|
7=Start Contact Failure
|
|
8=Voltage Sensing Failure"
|
|
|
|
--#TYPE "APC XATS: Internal fault cleared."
|
|
--#SUMMARY "ATS internal fault cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 400
|
|
|
|
xATSEngineStartAsserted TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The XATS has asserted the Engine Start contact.
|
|
This should result in the generator producing output voltage.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument indicates the reason that the start signal was asserted
|
|
1=Unknown, 2=S1 Low Voltage, 3=S1 High Voltage, 4=S1 Line Imbalance,
|
|
5=S1 Freq Range, 6=S1 Bad Rotation."
|
|
--#TYPE "APC XATS: Engine Start signal asserted."
|
|
--#SUMMARY "Engine Start asserted."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 401
|
|
|
|
xATSEngineStopAsserted TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The XATS has de-asserted the Engine Start contact.
|
|
This should result in the generator shutting down, and producing no output voltage.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Engine Stop signal asserted."
|
|
--#SUMMARY "Engine Stop asserted."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 402
|
|
|
|
xATSStartFailure TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator failed to start. After assertion of the
|
|
Engine Start signal, the quality of Source 2 was not seen as good.
|
|
This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument indicates the line quality at S2
|
|
1=Unknown, 2=S2 Low Voltage, 3=S2 High Voltage, 4=S2 Line Imbalance,
|
|
4=S2 Freq Range, 5=S2 Bad Rotation."
|
|
--#TYPE "APC XATS: Generator failed to start alarm."
|
|
--#SUMMARY "Generator failed to start."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 403
|
|
|
|
xATSStopFailure TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The generator failed to stop. After de-assertion of the
|
|
Engine Start signal, the quality of Source 2 continued to be seen as good.
|
|
This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Generator failed to stop alarm."
|
|
--#SUMMARY "Generator failed to stop."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 404
|
|
|
|
xATSNotInAutomaticMode TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Automatic Transfer Switch is not in automatic mode.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The xATSSwitchStatusAutoSwitchStatus OID and the
|
|
xATSSwitchStatusAutoSwitchOperationalMode OID
|
|
can provide more information about the state of the XATS."
|
|
--#TYPE "APC XATS: XATS is not-in-automatic mode."
|
|
--#SUMMARY "ATS not in auto."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 405
|
|
|
|
xATSNotInAutomaticModeCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Automatic Transfer Switch is in automatic mode.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: XATS in auto mode."
|
|
--#SUMMARY "ATS in auto mode."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 406
|
|
|
|
xATSEpoTripped TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The device's Emergency Power Off (EPO) circuit is tripped.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Emergency Power Off (EPO) tripped."
|
|
--#SUMMARY "EPO tripped."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 407
|
|
|
|
xATSEpoReset TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been
|
|
reset to the armed position.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Emergency Power Off (EPO) reset."
|
|
--#SUMMARY "EPO armed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 408
|
|
|
|
xATSEpoTestMode TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The device's Emergency Power Off (EPO) circuit has been
|
|
switched back to the test position.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Emergency Power Off (EPO) in test mode."
|
|
--#SUMMARY "EPO disabled."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 409
|
|
|
|
xATSEpoArmed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been
|
|
switched back to the armed position.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Emergency Power Off (EPO) enabled."
|
|
--#SUMMARY "EPO armed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 410
|
|
|
|
xATSTestInitiated TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A scheduled test has been initiated.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the type of test initiated (1=scheduled, 2=manual)."
|
|
--#TYPE "APC XATS: Test initiated."
|
|
--#SUMMARY "Test initiated."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 411
|
|
|
|
xATSTestCanceled TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The scheduled test has been canceled
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the type of test initiated (1=scheduled, 2=manual)."
|
|
--#TYPE "APC XATS: Test canceled."
|
|
--#SUMMARY "Test canceled."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 412
|
|
|
|
xATSTestFailed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The initiated test has failed.
|
|
This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Initiated test failed."
|
|
--#SUMMARY "Initiated test failed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 413
|
|
|
|
xATSTestPassed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The initiated test has passed
|
|
switched back to the armed position.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Initiated test passed."
|
|
--#SUMMARY "Initiated test passed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 414
|
|
|
|
xATSInputContactStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A user input contact on the device has changed to its abnormal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the input contact number.
|
|
The fourth argument is the input contact name.
|
|
The fifth argument is the input contact state (1=OPEN, 2=CLOSED).
|
|
The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)."
|
|
--#TYPE "APC XATS: Input contact has changed to its abnormal state."
|
|
--#SUMMARY "Input contact has changed to its abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 415
|
|
|
|
xATSInputContactStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A user input contact on the device has changed to its normal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the input contact number.
|
|
The fourth argument is the input contact name.
|
|
The fifth argument is the input contact state (1=OPEN, 2=CLOSED).
|
|
The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)."
|
|
--#TYPE "APC XATS: Input contact has changed to its normal state."
|
|
--#SUMMARY "Input contact has changed to its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 416
|
|
|
|
xATSRemoteStartContactMismatch TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The state of the generator's Remote Start input
|
|
and the ATS's Engine Start output do not match.
|
|
This indicates something wrong in the Engine Start wiring,
|
|
which must be corrected. This condition will prevent the
|
|
generator from being started when needed.
|
|
|
|
(See also: xATSGeneratorStatusRemoteStart
|
|
and xATSSwitchStatusEngineStartSignal OIDs)
|
|
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Generator/ATS start contact mismatch."
|
|
--#SUMMARY "Generator/ATS start contact mismatch."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 417
|
|
|
|
xATSRemoteStartContactMismatchCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Mismatch in the state of the generator's
|
|
Remote Start input and the ATS's Engine Start output as been resolved.
|
|
This indicates something wrong in the Engine Start wiring,
|
|
which must be corrected. This condition will prevent the
|
|
generator from being started when needed.
|
|
|
|
(See also: xATSGeneratorStatusRemoteStart
|
|
and xATSSwitchStatusEngineStartSignal OIDs)
|
|
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Generator/ATS start contact mismatch cleared."
|
|
--#SUMMARY "Generator/ATS start contact mismatch cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 418
|
|
|
|
xATSDoorOpenAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The XATS exterior panel door is open.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Panel door is open alarm."
|
|
--#SUMMARY "Panel door open alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 419
|
|
|
|
xATSDoorOpenAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The external door to the device is closed.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Panel door open alarm cleared."
|
|
--#SUMMARY "Panel door open alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 420
|
|
|
|
xATSDCBackupAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The XATS's DC backup has been lost. The XATS will lose power
|
|
on Source 1 failure, causing the Engine Start signal to be asserted.
|
|
The XATS will then restart from Source 2.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: DC backup failure."
|
|
--#SUMMARY "ATS DC backup failure."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 421
|
|
|
|
xATSDCBackupAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: DC backup alarm has been cleared in the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: DC backup alarm cleared."
|
|
--#SUMMARY "DC backup alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 422
|
|
|
|
-- xATS Generator Traps
|
|
|
|
xATSGeneratorLowCoolantLevelAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Low coolant level has been detected in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator low coolant level alarm."
|
|
--#SUMMARY "Generator low coolant level alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 423
|
|
|
|
xATSGeneratorLowCoolantLevelAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The detected low coolant level has been cleared in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator low coolant level alarm cleared."
|
|
--#SUMMARY "Generator low coolant level alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 424
|
|
|
|
xATSGeneratorVeryLowCoolantLevelAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Very low coolant level has been detected in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator very low coolant level alarm."
|
|
--#SUMMARY "Generator very low coolant level alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 425
|
|
|
|
xATSGeneratorVeryLowCoolantLevelAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The detected Very low coolant level has been cleared in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator very low coolant level alarm cleared."
|
|
--#SUMMARY "Generator very low coolant level alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 426
|
|
|
|
xATSGeneratorHighCoolantTempAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: High coolant temperature has been detected in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator high coolant temperature alarm."
|
|
--#SUMMARY "Generator high coolant temperature alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 427
|
|
|
|
xATSGeneratorHighCoolantTempAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The detected high coolant temperature has been cleared in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator high coolant temperature alarm cleared."
|
|
--#SUMMARY "Generator high coolant temperature alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 428
|
|
|
|
xATSGeneratorVeryHighCoolantTempAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Very high coolant temperature has been detected in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator very high coolant temperature alarm."
|
|
--#SUMMARY "Generator very high coolant temperature alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 429
|
|
|
|
xATSGeneratorVeryHighCoolantTempAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The Very high coolant temperature condition has been cleared in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator very high coolant temperature alarm cleared."
|
|
--#SUMMARY "Generator very high coolant temperature alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 430
|
|
|
|
xATSGeneratorLowCoolantTempAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Low coolant temperature has been detected in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator low coolant temperature alarm."
|
|
--#SUMMARY "Generator low coolant temperature alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 431
|
|
|
|
xATSGeneratorLowCoolantTempAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The low coolant temperature condition has been cleared in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator low coolant temperature alarm cleared."
|
|
--#SUMMARY "Generator low coolant temperature alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 432
|
|
|
|
xATSGeneratorLowOilLevelAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Low oil level has been detected in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator low oil level alarm."
|
|
--#SUMMARY "Generator low oil level alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 433
|
|
|
|
xATSGeneratorLowOilLevelAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Low oil level alarm has been cleared in the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator low oil level alarm cleared."
|
|
--#SUMMARY "Generator low oil level alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 434
|
|
|
|
xATSGeneratorLowBatteryVoltDuringCrankAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator's battery voltage has been detected
|
|
as low while cranking the engine.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Low batt. voltage while cranking alarm."
|
|
--#SUMMARY "Generator low battery volts while cranking alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 435
|
|
|
|
xATSGeneratorLowBatteryVoltDuringCrankAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The generator's low battery voltage while
|
|
cranking condition has been cleared.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "XGEN: Generator low batt. voltage while cranking alarm cleared."
|
|
--#SUMMARY "Generator low battery volts while cranking alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 436
|
|
|
|
xATSGeneratorVeryLowBatteryVoltDuringCrankAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator's battery voltage has been detected
|
|
as very low while cranking the engine.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "XGEN: Generator v.low battery voltage while cranking alarm."
|
|
--#SUMMARY "Generator v.low battery volts while cranking alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 437
|
|
|
|
xATSGeneratorVeryLowBatteryVoltDuringCrankAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The generator's high battery voltage while
|
|
cranking condition has been cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "XGEN: Generator v.low batt volt, while cranking alarm cleared."
|
|
--#SUMMARY "Generator v.low battery volts while cranking alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 438
|
|
|
|
xATSGeneratorEStop TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator's emergency stop input has been activated.
|
|
After the emergency stop signal has been removed, the E-Stop condition
|
|
must be cleared before the generator can be started again.
|
|
E-Stop conditions can only be cleared via the generator front panel.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code.
|
|
The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE)."
|
|
--#TYPE "APC XGEN: Generator emergency stop engaged."
|
|
--#SUMMARY "Generator emergency stop engaged."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 439
|
|
|
|
xATSGeneratorEStopCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The generator's emergency stop condition has been cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code.
|
|
The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE)."
|
|
--#TYPE "APC XGEN: Generator emergency stop condition cleared."
|
|
--#SUMMARY "Generator emergency stop condition cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 440
|
|
|
|
xATSGeneratorHighBatteryVolt TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The generator's battery voltage has been detected as high.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator high battery voltage."
|
|
--#SUMMARY "Generator high battery volts."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 441
|
|
|
|
xATSGeneratorHighBatteryVoltCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The detected high battery voltage has been cleared, on the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator high battery voltage condition cleared."
|
|
--#SUMMARY "Generator high battery volts condition cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 442
|
|
|
|
xATSGeneratorLowBatteryVolt TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator's battery voltage has been detected as low.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator low battery voltage."
|
|
--#SUMMARY "Generator low battery volts."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 443
|
|
|
|
xATSGeneratorLowBatteryVoltCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The detected low battery voltage has been cleared, on the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator low battery voltage condition cleared."
|
|
--#SUMMARY "Generator low battery volts condition cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 444
|
|
|
|
xATSGeneratorControlSwitchNotAuto TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The control switch on the generator is not in auto position.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator not-in-automatic mode."
|
|
--#SUMMARY "Generator not-in-auto."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 445
|
|
|
|
xATSGeneratorControlSwitchNotAutoCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The control switch on the generator is in auto position.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator automatic mode restored."
|
|
--#SUMMARY "Generator not-in-auto cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 446
|
|
|
|
xATSGeneratorLowOilPressure TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator's oil pressure has been detected as low.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator low oil pressure."
|
|
--#SUMMARY "Generator low oil pressure."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 447
|
|
|
|
xATSGeneratorLowOilPressureCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The detected low oil pressure has been cleared, on the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator low oil pressure condition cleared."
|
|
--#SUMMARY "Generator low oil pressure condition cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 448
|
|
|
|
xATSGeneratorVeryLowOilPressure TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator's oil pressure has been detected as very low.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator v.low oil pressure."
|
|
--#SUMMARY "Generator v.low oil pressure."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 449
|
|
|
|
xATSGeneratorVeryLowOilPressureCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The detected v.low oil pressure has been cleared, on the generator.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator v.low oil pressure condition cleared."
|
|
--#SUMMARY "Generator v.low oil pressure condition cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 450
|
|
|
|
xATSGeneratorOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator is overloaded.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator is in overload event."
|
|
--#SUMMARY "Generator on overload event."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 451
|
|
|
|
xATSGeneratorOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The generator is running within loading limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator is in overload event cleared."
|
|
--#SUMMARY "Generator on overload event cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 452
|
|
|
|
xATSGeneratorLowACVEvent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator AC voltage is outside the acceptable bounds.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: State of the Generator AC voltage."
|
|
--#SUMMARY " State of the Generator AC voltage."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 453
|
|
|
|
xATSGeneratorLowACVEventCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The generator AC voltage is within normal bounds.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: State of the Generator AC voltage cleared."
|
|
--#SUMMARY "State of the Generator AC voltage cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 454
|
|
|
|
xATSGeneratorHighACVEvent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator AC voltage is outside the acceptable bounds.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: State of the Generator AC voltage."
|
|
--#SUMMARY " State of the Generator AC voltage."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 455
|
|
|
|
xATSGeneratorHighACVEventCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The generator AC voltage is within normal bounds.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: State of the Generator AC voltage cleared."
|
|
--#SUMMARY "State of the Generator AC voltage cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 456
|
|
|
|
xATSGeneratorOverspeed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator is running over the acceptable RPM.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator overspeed condition."
|
|
--#SUMMARY "Generator overspeed condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 457
|
|
|
|
xATSGeneratorOverspeedCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The generator overspeed shutdown has been cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator overspeed condition cleared."
|
|
--#SUMMARY "Generator overspeed condition cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 458
|
|
|
|
xATSGeneratorEngineCold TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator engine is cold, may not start.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator engine is cold, may not start."
|
|
--#SUMMARY "Generator engine is cold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 459
|
|
|
|
xATSGeneratorEngineColdCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The engine is not cold to start.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Engine is cold to start condition cleared."
|
|
--#SUMMARY "Engine is cold to start condition cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 460
|
|
|
|
xATSGeneratorOutputBreakerOpen TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generators output breaker has been detected as open.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator output breaker open alarm."
|
|
--#SUMMARY "Generator output breaker open."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 461
|
|
|
|
xATSGeneratorOutputBreakerOpenCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The engine is not cold to start.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator output breaker open alarm cleared."
|
|
--#SUMMARY "Generator output breaker open cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 462
|
|
|
|
xATSGeneratorLowFuelLevelAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The tank fuel level is below the limits specified
|
|
in the xATSGeneratorFuelSystemLowFuelLevelThreshold OID.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the measured fuel level in percent of full."
|
|
--#TYPE "APC XGEN: Low fuel level alarm."
|
|
--#SUMMARY "Generator low fuel level alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 463
|
|
|
|
xATSGeneratorLowFuelLevelAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The tank fuel level is back above the specified limit.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XGEN: Low fuel level alarm cleared."
|
|
--#SUMMARY "Generator low fuel level alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 464
|
|
|
|
xATSGeneratorVeryLowFuelLevelAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The tank fuel level is below the low threshold limits.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the measured tank fuel level in percent of full."
|
|
--#TYPE "APC XGEN: Very Low fuel level alarm."
|
|
--#SUMMARY "Generator very low fuel level alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 465
|
|
|
|
xATSGeneratorVeryLowFuelLevelAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The detected low tank level has been cleared in the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XGEN: Very low fuel level alarm cleared."
|
|
--#SUMMARY "Generator very low fuel level alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 466
|
|
|
|
xATSGeneratorLowRunTimeAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The estimated runtime is below the limits specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the estimated runtime in hours."
|
|
--#TYPE "APC XGEN: Low run time alarm."
|
|
--#SUMMARY "Generator low run time alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 467
|
|
|
|
xATSGeneratorLowRunTimeAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The detected low runtime has been cleared in the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XGEN: Low run time alarm cleared."
|
|
--#SUMMARY "Generator low run time alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 468
|
|
|
|
xATSGeneratorVeryLowRunTimeAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The estimated runtime is below the limits specified
|
|
in the xATSGeneratorFuelSystemVeryLowRunTimeThreshold OID.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the estimated runtime in hours."
|
|
--#TYPE "APC XGEN: Very low run time alarm."
|
|
--#SUMMARY "Generator very low run time alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 469
|
|
|
|
xATSGeneratorVeryLowRunTimeAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The detected low runtime has been cleared in the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XGEN: Very low run time alarm cleared."
|
|
--#SUMMARY "Generator very low run time alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 470
|
|
|
|
xATSGeneratorServiceDueAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The generator is due for scheduled service.
|
|
Generation of this alarm is based on calendar days since
|
|
and/or actual generator run-hours since last service.
|
|
This alarm is cleared using the xATSGeneratorServiceResetRecord OID.
|
|
|
|
(See also: xATSGeneratorServiceCalendarIntervalThreshold
|
|
and xATSGeneratorServiceRunHoursThreshold OIDs)
|
|
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Generator scheduled maintenance is due."
|
|
--#SUMMARY "Generator maintenance due."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 471
|
|
|
|
xATSGeneratorServiceDueAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The generator's service registers have been reset.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: Generator service due alarm is cleared."
|
|
--#SUMMARY "Generator service alarm is cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 472
|
|
|
|
xATSGeneratorShutdown TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator is shutdown.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator shutdown."
|
|
--#SUMMARY "Generator shutdown"
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 473
|
|
|
|
xATSGeneratorShutdownCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The generator shutdown alarm is cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator shutdown is cleared."
|
|
--#SUMMARY "Generator shutdown is cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 474
|
|
|
|
xATSGeneratorBatteryCharger TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The generator battery charger is nonfunctional.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator batt. charger is nonfunctional."
|
|
--#SUMMARY "Generator battery charger is nonfunctional"
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 475
|
|
|
|
xATSGeneratorBatteryChargerCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Fault in the generator battery charger is cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Fault in the generator battery charger is cleared."
|
|
--#SUMMARY "Fault in the generator battery charger is cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 476
|
|
|
|
xATSGeneratorGenericEvent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Any generic generator event.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator generic event."
|
|
--#SUMMARY "Generator generic event."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 477
|
|
|
|
xATSGeneratorGenericEventCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Generated generic generator event is cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generic generator event is cleared."
|
|
--#SUMMARY "Generic generator event is cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 478
|
|
|
|
-- xPDU Traps (part 2)
|
|
|
|
xPDUInternalCommErrorCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Internal communication has been restored.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: Internal Communication error cleared."
|
|
--#SUMMARY "Communication error cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 479
|
|
|
|
|
|
xPDUSystemStateAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The PDU's breakers (Q1, Q2 & Q3) are in a configuration that might lead
|
|
to system unavailability. it may signify a temporary condition, when the breakers
|
|
are placed in an atypical manner as the user transitions to (UPS OPERATION or MAINTENANCE BYPASS)
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the type of state change (1=NO UPS INPUT, 2=NO PANEL FEED, 3=ATYPICAL BYPASS MODE).
|
|
note: The NO_PANEL_FEED alarm is applicable only for PDUs with system bypass."
|
|
--#TYPE "APC XPDU: System state change alarm."
|
|
--#SUMMARY "PDU state change alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 480
|
|
|
|
xPDUSystemStateAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The PDU's breakers (Q1, Q2 & Q3) are set in a configuration
|
|
that is a non-alarm state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the type of state change (1=NO UPS INPUT, 2=NO PANEL FEED, 3=ATYPICAL BYPASS MODE).
|
|
note: The NO_PANEL_FEED alarm is applicable only for PDUs with system bypass."
|
|
--#TYPE "APC XPDU: Normal system state change."
|
|
--#SUMMARY "PDU normal state change."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 481
|
|
|
|
xPDUEpoTestMode TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The device's Emergency Power Off (EPO) circuit has been
|
|
switched back to the test position.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: Emergency Power Off (EPO) in test mode."
|
|
--#SUMMARY "EPO disabled."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 482
|
|
|
|
xPDUEpoArmed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been
|
|
switched back to the armed position.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: Emergency Power Off (EPO) enabled."
|
|
--#SUMMARY "EPO armed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 483
|
|
|
|
xPDUFuseBlownAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: One or more fuses in this PDU have been detected as open.
|
|
These fuses are in the feed to the UPS associated with this PDU.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1, 2=L2, 3=L3)."
|
|
--#TYPE "APC XPDU: Check fuse alarm."
|
|
--#SUMMARY "Fuse detected opened."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 484
|
|
|
|
xPDUFuseBlownAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A previous check fuse alarm in this PDU has cleared.
|
|
These fuses are in the feed to the UPS associated with this PDU.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase (1=L1, 2=L2, 3=L3)."
|
|
--#TYPE "APC XPDU: Check fuse alarm cleared."
|
|
--#SUMMARY "Fuse alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 485
|
|
|
|
xPDUBreakerPositionAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
|
|
mtrapargsInteger, mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A PDU breaker is in a state that compromises system availability.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE, 4=OUTPUT).
|
|
note: The OUTPUT breaker position alarm is applicable only for PDUs with no system bypass.
|
|
The fourth argument is the breaker position (1=OPEN, 2=CLOSED)."
|
|
--#TYPE "APC XPDU: Breaker position alarm."
|
|
--#SUMMARY "Breaker position alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 486
|
|
|
|
xPDUBreakerPositionAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU breaker is no longer in a state that compromises system availability.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE, 4=OUTPUT).
|
|
note: The OUTPUT breaker position alarm cleared is applicable only for PDUs with no system bypass."
|
|
--#TYPE "APC XPDU: Breaker position alarm cleared."
|
|
--#SUMMARY "Breaker alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 487
|
|
|
|
xPDUBreakerChangeEvent TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A system breaker or switch within the device has changed state.
|
|
They are generated when any of the Q1, Q2 or Q3 breakers have changed states.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the breaker that has changed
|
|
(1=UPS FEED (Q1), 2=UPS OUTPUT(Q2), 3=MAINTENANCE BYPASS (Q3).
|
|
The fourth argument is the state of the breaker that has changed (1=OPEN, 2=CLOSED).
|
|
The fifth argument is a 8-bit field representing the state of all breakers in the system,
|
|
when any of one of the Q1, Q2 or Q3 breakers have changed state.
|
|
|
|
The bit map is represented in the following manner (b7, b6 ... b0)
|
|
b0 - UPS FEED (Q1)
|
|
b1 - MAINTENANCE BYPASS (Q3)
|
|
b2 - UPS OUTPUT (Q2)
|
|
b3 - MAIN INPUT
|
|
b4 - BYPASS INPUT
|
|
b5 - CROSS-TIE OUTPUT
|
|
|
|
Example: value of 60 (0x3C) indicates that the CROSS_TIE, BYPASS and MAIN INPUT, and Q2 breakers
|
|
are CLOSED and Q3, Q1 breakers are OPEN."
|
|
--#TYPE "APC XPDU: Breaker/switch change event."
|
|
--#SUMMARY "Breaker/switch change event."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 488
|
|
|
|
xPDUDataCommMismatchError TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A data incompatibility exists within the device. This
|
|
is typically the result of mismatches between firmware revisions
|
|
of the transfer switch controller and the Network Management interface.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: Data mismatch error."
|
|
--#SUMMARY "XPDU data mismatch error."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 489
|
|
|
|
xPDUDataCommMismatchErrorCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The internal data incompatibility has been resolved.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: data mismatch error cleared."
|
|
--#SUMMARY "XPDU data mismatch error cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 490
|
|
|
|
xPDUSystemInMaintenanceBypassMode TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The PDU state has changed to maintenance bypass mode.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: System state changed to maintenance bypass."
|
|
--#SUMMARY "PDU state changed to maintenance bypass."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 491
|
|
|
|
xPDUSystemInUPSOperationalMode TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The PDU state has changed to UPS operational mode.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XPDU: System state changed to UPS operational."
|
|
--#SUMMARY "PDU state changed to UPS operational."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 492
|
|
|
|
xATSGeneratorFuelTankRuptureAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Detected a rupture in the inner wall of the generator fuel tank.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator inner wall rupture alarm."
|
|
--#SUMMARY "Generator inner wall rupture alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 493
|
|
|
|
xATSGeneratorFuelTankRuptureAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The rupture in the inner wall of the generator is not detected.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator inner wall rupture alarm cleared."
|
|
--#SUMMARY "Generator inner wall rupture alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 494
|
|
|
|
xATSGeneratorGroundFaultAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Generator ground fault alarm.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator ground fault alarm."
|
|
--#SUMMARY "Generator ground fault alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 495
|
|
|
|
xATSGeneratorGroundFaultAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Generator ground fault alarm cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the OEM's fault/event code."
|
|
--#TYPE "APC XGEN: Generator ground fault alarm cleared."
|
|
--#SUMMARY "Generator ground fault alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 496
|
|
|
|
xATSOutputLoadPoweredByGeneratorAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The system load on the output of the ATS is being powered by source 2 (generator).
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument indicates if the load is powered by the generator,
|
|
when 'load testing' the generator (1 = LIVE, 2 = TEST)."
|
|
--#TYPE "APC XATS: System load powered by generator alarm."
|
|
--#SUMMARY "System load powered by generator."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 497
|
|
|
|
xATSOutputLoadPoweredByGeneratorAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The system load on the output of the ATS is no longer being powered by source 2 (generator).
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: System load powered by generator alarm cleared."
|
|
--#SUMMARY "System load powered by generator alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 498
|
|
|
|
xAPCControllerFirmwareUpdateTransferStart TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString05, mtrapargsString04, mtrapargsString02, mtrapargsString03,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Start controller firmware transfer in the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host model name that initiated the transfer.
|
|
The third argument is the name of the file that is transferred.
|
|
The fourth argument is the updated revision of the file, if available
|
|
The fifth argument is the reason for the update, if available
|
|
(1=User request, 2=Automatic upgrade by NMC, 3=Unknown)."
|
|
--#TYPE "APC: Start update transfer."
|
|
--#SUMMARY "Start update transfer."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 499
|
|
|
|
xAPCControllerFirmwareUpdateTransferComplete TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString05, mtrapargsString04, mtrapargsString02,
|
|
mtrapargsString03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Transfer of controller firmware was completed in the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device model name that completed the transfer.
|
|
The third argument is the name of the file that was transferred.
|
|
The fourth argument is the revision of the file that was transferred, if available."
|
|
--#TYPE "APC : Update transfer complete."
|
|
--#SUMMARY "Update transfer complete."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 500
|
|
|
|
|
|
xAPCControllerFirmwareUpdateTransferFailed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString05, mtrapargsString04, mtrapargsString02,
|
|
mtrapargsString03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Transfer of controller firmware failed.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device model name that failed to transfer.
|
|
The third argument is the name of the file that failed the transfer, if available.
|
|
The fourth argument is the reason for failure."
|
|
--#TYPE "APC: Update transfer failed."
|
|
--#SUMMARY "Update transfer failed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 501
|
|
|
|
upsPfcInputRelayFailure TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The PFC (Power Factor Correction) input relay failure exists."
|
|
--#TYPE "APC UPS: The PFC input relay failure exists."
|
|
--#SUMMARY "The PFC (Power Factor Correction) input relay failure exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 502
|
|
|
|
upsPfcInputRelayFailureCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The PFC (Power Factor Correction) input relay failure cleared."
|
|
--#TYPE "APC UPS: The PFC input relay failure cleared."
|
|
--#SUMMARY "The PFC (Power Factor Correction) input relay failure cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 503
|
|
|
|
upsInverterOverTemperature TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The inverter over temperature condition exists."
|
|
--#TYPE "APC UPS: The inverter over temperature condition exists."
|
|
--#SUMMARY "The inverter over temperature condition exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 504
|
|
|
|
upsInverterOverTemperatureCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The inverter over temperature condition cleared."
|
|
--#TYPE "APC UPS: The inverter over temperature condition cleared."
|
|
--#SUMMARY "The inverter over temperature condition cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 505
|
|
|
|
upsBatteryOverVoltage TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The battery over voltage condition exists."
|
|
--#TYPE "APC UPS: The battery over voltage condition exists."
|
|
--#SUMMARY "The battery over voltage condition exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 506
|
|
|
|
upsBatteryOverVoltageCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The battery over voltage condition cleared."
|
|
--#TYPE "APC UPS: The battery over voltage condition cleared."
|
|
--#SUMMARY "The battery over voltage condition cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 507
|
|
|
|
upsEepromFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The EEPROM fault exists."
|
|
--#TYPE "APC UPS: The EEPROM fault exists."
|
|
--#SUMMARY "The EEPROM fault exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 508
|
|
|
|
upsEepromFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The EEPROM fault cleared."
|
|
--#TYPE "APC UPS: The EEPROM fault cleared."
|
|
--#SUMMARY "The EEPROM fault cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 509
|
|
|
|
-- rARU Traps (part 2)
|
|
|
|
aruFanRuntimeAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The total running hours for a fan has exceeded
|
|
the run hour threshold.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name.
|
|
The fifth argument indicates which fan in the ARU."
|
|
--#TYPE "APC ARU: Fan Runhour Warning."
|
|
--#SUMMARY "Fan Runhour Alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 510
|
|
|
|
aruFanRuntimeAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The total running hours for a fan is no longer
|
|
above the fan runhour threshold.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name.
|
|
The fifth argument indicates which fan in the ARU."
|
|
--#TYPE "APC ARU: Fan Runhour Alarm Cleared."
|
|
--#SUMMARY "Fan Runhour Alarm Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 511
|
|
|
|
|
|
aruFanPoorPerformanceAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Poor fan performance has been detected in the ARU,
|
|
indicating that the fan may be close to failing.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name.
|
|
The fifth argument indicates which fan in the ARU."
|
|
--#TYPE "APC ARU: Poor Fan Performance Warning."
|
|
--#SUMMARY "Fan Health Alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 512
|
|
|
|
aruFanPoorPerformanceAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Fan performance is no longer degraded.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name.
|
|
The fifth argument indicates which fan in the ARU."
|
|
--#TYPE "APC ARU: Poor Fan Performance Warning Cleared."
|
|
--#SUMMARY "Fan Health Alarm Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 513
|
|
|
|
aruRedundantPowerLostAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: One of the redundant line cords on the ARU is no longer receiving AC power.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: Redundant AC Input is not Present."
|
|
--#SUMMARY "AC Redundancy Lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 514
|
|
|
|
aruRedundantPowerLostAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
|
|
rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Line-cord redundancy has been restored to the ARU.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the ARU number.
|
|
The fourth argument is the ARU name."
|
|
--#TYPE "APC ARU: Redundant AC Input is Present."
|
|
--#SUMMARY "AC Redundancy Restored."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 515
|
|
|
|
apcDeviceConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A device configuration change has been made on the device.
|
|
The first argument is the device serial number.
|
|
The second argument is the device name.
|
|
The third argument is a secondary device id number."
|
|
--#TYPE "APC: A device configuration change on a device."
|
|
--#SUMMARY "A device configuration change has been made on a device."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 516
|
|
|
|
apcEnvSensorConnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A sensor has been connected to the host device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Sensor Connected."
|
|
--#SUMMARY "Sensor Connected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 517
|
|
|
|
apcEnvSensorDisconnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A sensor has been disconnected from the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Sensor Disconnected."
|
|
--#SUMMARY "Sensor Disconnected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 518
|
|
|
|
apcEnvMaxTempThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Max temperature threshold violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Max temperature threshold violation."
|
|
--#SUMMARY "Max temperature threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 519
|
|
|
|
apcEnvMaxTempThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Max temperature threshold violation cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Max temperature threshold violation cleared."
|
|
--#SUMMARY "Max temperature threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 520
|
|
|
|
apcEnvHighTempThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: High temperature threshold violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: High temperature threshold violation."
|
|
--#SUMMARY "High temperature threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 521
|
|
|
|
apcEnvHighTempThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: High temperature threshold violation cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: High temperature threshold violation cleared."
|
|
--#SUMMARY "High temperature threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 522
|
|
|
|
apcEnvLowTempThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Low temperature threshold violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Low temperature threshold violation."
|
|
--#SUMMARY "Low temperature threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 523
|
|
|
|
apcEnvLowTempThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Low temperature threshold violation cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Low temperature threshold violation cleared."
|
|
--#SUMMARY "Low temperature threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 524
|
|
|
|
apcEnvMinTempThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Min temperature threshold violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Min temperature threshold violation."
|
|
--#SUMMARY "Min temperature threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 525
|
|
|
|
apcEnvMinTempThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Min temperature threshold violation cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The sixth argument is the sensor number.
|
|
The seventh argument is the sensor name."
|
|
--#TYPE "APC ENV: Min temperature threshold violation cleared."
|
|
--#SUMMARY "Min temperature threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 526
|
|
|
|
apcEnvSTIncTempRateViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Short-term increasing temperature rate violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Short-term inc. temp rate violation."
|
|
--#SUMMARY "Short-term inc. temp rate violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 527
|
|
|
|
apcEnvSTIncTempRateViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Short-term increasing temperature rate cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Short-term inc. temp rate violation cleared."
|
|
--#SUMMARY "Short-term inc. temp rate violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 528
|
|
|
|
apcEnvSTDecTempRateViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Short-term decreasing temperature rate violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Short-term dec. temp rate violation."
|
|
--#SUMMARY "Short-term dec. temp rate violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 529
|
|
|
|
apcEnvSTDecTempRateViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Short-term decreasing temperature rate cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Short-term dec. temp rate violation cleared."
|
|
--#SUMMARY "Short-term dec. temp rate violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 530
|
|
|
|
apcEnvLTIncTempRateViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Long-term increasing temperature rate violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Long-term inc. temp rate violation."
|
|
--#SUMMARY "Long-term inc. temp rate violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 531
|
|
|
|
apcEnvLTIncTempRateViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Long-term increasing temperature rate cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Long-term inc. temp rate violation cleared."
|
|
--#SUMMARY "Long-term inc. temp rate violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 532
|
|
|
|
apcEnvLTDecTempRateViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Long-term decreasing temperature rate violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Long-term dec. temp rate violation."
|
|
--#SUMMARY "Long-term dec. temp rate violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 533
|
|
|
|
apcEnvLTDecTempRateViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Long-term decreasing temperature rate cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Long-term dec. temp rate violation cleared."
|
|
--#SUMMARY "Long-term dec. temp rate violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 534
|
|
|
|
apcEnvMaxHumidityThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Max humidity threshold violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Max humidity threshold violation."
|
|
--#SUMMARY "Max humidity threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 535
|
|
|
|
apcEnvMaxHumidityThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Max humidity threshold violation cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Max humidity threshold violation cleared."
|
|
--#SUMMARY "Max humidity threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 536
|
|
|
|
apcEnvHighHumidityThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: High humidity threshold violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: High humidity threshold violation."
|
|
--#SUMMARY "High humidity threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 537
|
|
|
|
apcEnvHighHumidityThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: High humidity threshold violation cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: High humidity threshold violation cleared."
|
|
--#SUMMARY "High humidity threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 538
|
|
|
|
apcEnvLowHumidityThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Low humidity threshold violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Low humidity threshold violation."
|
|
--#SUMMARY "Low humidity threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 539
|
|
|
|
apcEnvLowHumidityThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Low humidity threshold violation cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Low humidity threshold violation cleared."
|
|
--#SUMMARY "Low humidity threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 540
|
|
|
|
apcEnvMinHumidityThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Min humidity threshold violated on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Min humidity threshold violation."
|
|
--#SUMMARY "Min humidity threshold violation."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 541
|
|
|
|
apcEnvMinHumidityThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Min humidity threshold violation cleared on the sensor.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the sensor number.
|
|
The fifth argument is the sensor name."
|
|
--#TYPE "APC ENV: Min humidity threshold violation cleared."
|
|
--#SUMMARY "Min humidity threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 542
|
|
|
|
apcBeaconConnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A beacon has been connected to the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number."
|
|
--#TYPE "APC: Beacon Connected."
|
|
--#SUMMARY "Beacon Connected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 543
|
|
|
|
apcBeaconDisconnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A beacon has been disconnected from the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number. "
|
|
--#TYPE "APC: Beacon Disconnected."
|
|
--#SUMMARY "Beacon Disconnected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 544
|
|
|
|
apcBeaconOn TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A beacon has gone on (activated).
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number. "
|
|
--#TYPE "APC: Beacon On."
|
|
--#SUMMARY "Beacon On."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 545
|
|
|
|
apcBeaconOff TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A beacon has gone off (deactivated).
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number. "
|
|
--#TYPE "APC: Beacon Off."
|
|
--#SUMMARY "Beacon Off."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 546
|
|
|
|
apcOutletStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, mtrapargsString04,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An outlet on the device has changed to its abnormal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the outlet number.
|
|
The fifth argument is the outlet name.
|
|
The sixth argument is the current outlet state (1=ON, 2=OFF).
|
|
The seventh argument is the configured normal outlet state (1=ON, 2=OFF)."
|
|
--#TYPE "APC: Outlet has changed to its abnormal state."
|
|
--#SUMMARY "Outlet has changed to its abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 547
|
|
|
|
apcOutletStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger, mtrapargsString04,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on the device has changed to its normal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the outlet number.
|
|
The fifth argument is the outlet name.
|
|
The sixth argument is the current outlet state (1=ON, 2=OFF).
|
|
The seventh argument is the configured normal outlet state (1=ON, 2=OFF)."
|
|
--#TYPE "APC: Outlet has changed to its normal state."
|
|
--#SUMMARY "Outlet has changed to its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 548
|
|
|
|
apcOutputRelayStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger,
|
|
mtrapargsString04, mtrapargsInteger02,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An output relay on the device has changed to its abnormal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the output relay number.
|
|
The fifth argument is the output relay name.
|
|
The sixth argument is the current output relay state (1=CLOSED, 2=OPEN).
|
|
The seventh argument is the configured normal output relay state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC: Output Relay has changed to its abnormal state."
|
|
--#SUMMARY "Output Relay has changed to its abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 549
|
|
|
|
apcOutputRelayStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger,
|
|
mtrapargsString04, mtrapargsInteger02,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An output relay on the device has changed to its normal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the output relay number.
|
|
The fifth argument is the output relay name.
|
|
The sixth argument is the current output relay state (1=CLOSED, 2=OPEN).
|
|
The seventh argument is the configured normal output relay state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC: Output Relay has changed to its normal state."
|
|
--#SUMMARY "Output Relay has changed to its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 550
|
|
|
|
apcHardwareStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
|
|
"SEVERE: The device's hardware is improperly configured and operating outside
|
|
normal bounds for the hardware. This can be caused by improper devices being
|
|
connected to device ports or Alink Current limit detection.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is a hardware specific state code."
|
|
|
|
--#TYPE "APC: Hardware is in an abnormal state."
|
|
--#SUMMARY "Hardware is in an abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 551
|
|
|
|
apcHardwareStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsInteger04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The device's hardware is in its normal operational state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number."
|
|
--#TYPE "APC EMS: Hardware is in a normal state."
|
|
--#SUMMARY "Hardware is in its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 552
|
|
|
|
apcCriticalDiscreteInputContactStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger,
|
|
mtrapargsString04, mtrapargsInteger02,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A discrete input contact on the device has changed to its abnormal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input contact number.
|
|
The fifth argument is the input contact name.
|
|
The sixth argument is the input contact state (1=CLOSED, 2=OPEN).
|
|
The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC: Discrete input contact has changed to its abnormal state."
|
|
--#SUMMARY "Discrete input contact has changed to its abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 553
|
|
|
|
apcCriticalDiscreteInputContactStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger,
|
|
mtrapargsString04, mtrapargsInteger02,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A discrete input contact on the device has changed to its normal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input contact number.
|
|
The fifth argument is the input contact name.
|
|
The sixth argument is the input contact state (1=CLOSED, 2=OPEN).
|
|
The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC: Discrete input contact has changed to its normal state."
|
|
--#SUMMARY "Discrete input contact has changed to its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 554
|
|
|
|
apcWarningDiscreteInputContactStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger,
|
|
mtrapargsString04, mtrapargsInteger02,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A discrete input contact on the device has changed to its abnormal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input contact number.
|
|
The fifth argument is the input contact name.
|
|
The sixth argument is the input contact state (1=CLOSED, 2=OPEN).
|
|
The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC: Discrete input contact has changed to its abnormal state."
|
|
--#SUMMARY "Discrete input contact has changed to its abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 555
|
|
|
|
apcWarningDiscreteInputContactStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger,
|
|
mtrapargsString04, mtrapargsInteger02,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A discrete input contact on the device has changed to its normal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input contact number.
|
|
The fifth argument is the input contact name.
|
|
The sixth argument is the input contact state (1=CLOSED, 2=OPEN).
|
|
The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC: Discrete input contact has changed to its normal state."
|
|
--#SUMMARY "Discrete input contact has changed to its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 556
|
|
|
|
apcInformationalDiscreteInputContactStateAbnormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger,
|
|
mtrapargsString04, mtrapargsInteger02,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A discrete input contact on the device has changed to its abnormal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input contact number.
|
|
The fifth argument is the input contact name.
|
|
The sixth argument is the input contact state (1=CLOSED, 2=OPEN).
|
|
The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC: Discrete input contact has changed to its abnormal state."
|
|
--#SUMMARY "Discrete input contact has changed to its abnormal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 557
|
|
|
|
apcInformationalDiscreteInputContactStateNormal TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsInteger,
|
|
mtrapargsString04, mtrapargsInteger02,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A discrete input contact on the device has changed to its normal state.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input contact number.
|
|
The fifth argument is the input contact name.
|
|
The sixth argument is the input contact state (1=CLOSED, 2=OPEN).
|
|
The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN)."
|
|
--#TYPE "APC: Discrete input contact has changed to its normal state."
|
|
--#SUMMARY "Discrete input contact has changed to its normal state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 558
|
|
|
|
apcAnalogInputMaxThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Maximum threshold violated on an analog input.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input number.
|
|
The fifth argument is the input name."
|
|
--#TYPE "APC: Maximum threshold violation on analog input."
|
|
--#SUMMARY "Max threshold violation on input."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 559
|
|
|
|
apcAnalogInputMaxThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Maximum threshold violation cleared on the analog input.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input number.
|
|
The fifth argument is the input name."
|
|
--#TYPE "APC: Max threshold violation cleared."
|
|
--#SUMMARY "Max threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 560
|
|
|
|
apcAnalogInputHighThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: High threshold violated on an analog input.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input number.
|
|
The fifth argument is the input name."
|
|
--#TYPE "APC: High threshold violation on analog input."
|
|
--#SUMMARY "High threshold violation on input."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 561
|
|
|
|
apcAnalogInputHighThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: High threshold violation cleared on the analog input.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input number.
|
|
The fifth argument is the input name."
|
|
--#TYPE "APC: High threshold violation cleared."
|
|
--#SUMMARY "High threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 562
|
|
|
|
apcAnalogInputLowThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Low threshold violated on an analog input.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input number.
|
|
The fifth argument is the input name."
|
|
--#TYPE "APC: Low threshold violation on analog input."
|
|
--#SUMMARY "Low threshold violation on input."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 563
|
|
|
|
apcAnalogInputLowThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Low threshold violation cleared on the analog input.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input number.
|
|
The fifth argument is the input name."
|
|
--#TYPE "APC: Low threshold violation cleared."
|
|
--#SUMMARY "Low threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 564
|
|
|
|
apcAnalogInputMinThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Minimum threshold violated on an analog input.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input number.
|
|
The fifth argument is the input name."
|
|
--#TYPE "APC: Min threshold violation on analog input."
|
|
--#SUMMARY "Min threshold violation on input."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 565
|
|
|
|
apcAnalogInputMinThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Minimum threshold violation cleared on the analog input.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is a secondary device id number.
|
|
The fourth argument is the input number.
|
|
The fifth argument is the input name."
|
|
--#TYPE "APC: Min threshold violation cleared."
|
|
--#SUMMARY "Min threshold violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 566
|
|
|
|
apcDeviceClearLostComms TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Lost communications reset command has been issued.
|
|
The first argument is the device serial number.
|
|
The second argument is the device name.
|
|
The third argument is a secondary device id number."
|
|
--#TYPE "APC: Lost communications reset command has been issued."
|
|
--#SUMMARY "Lost communications reset command has been issued."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 567
|
|
|
|
apcDeviceConnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A device has been connected to the host.
|
|
The first argument is the host serial number.
|
|
The second argument is the host name.
|
|
The third argument is the device number.
|
|
The fourth argument is the device name."
|
|
--#TYPE "APC: Device Connected."
|
|
--#SUMMARY "Device Connected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 568
|
|
|
|
apcDeviceDisconnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A device has been disconnected from the host.
|
|
The first argument is the host serial number.
|
|
The second argument is the host name.
|
|
The third argument is the device number.
|
|
The fourth argument is the device name."
|
|
--#TYPE "APC: Device Disconnected."
|
|
--#SUMMARY "Device Disconnected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 569
|
|
|
|
apcUnregisteredUserAccessDenied TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString04,
|
|
mtrapargsInteger, mtrapargsString05, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An unregistered user has tried to access the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argumant is the door identifier.
|
|
The fifth argument is the unregistered user's RFID."
|
|
--#TYPE "APC: Unregistered user."
|
|
--#SUMMARY "Unregistered user."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 570
|
|
|
|
|
|
apcRegisteredUserAccessDenied TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString04,
|
|
mtrapargsInteger, mtrapargsString05, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A registered user has been denied access to the device.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argumant is the door identifier.
|
|
The fifth argument is the user name."
|
|
--#TYPE "APC: Access denied."
|
|
--#SUMMARY "Access denied."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 571
|
|
|
|
apcRegisteredUserConfigChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsString05, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Registered user configuration change.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the user name."
|
|
--#TYPE "APC: Registered user configuration change."
|
|
--#SUMMARY "Registered user configuration change."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 572
|
|
|
|
apcDoorUnlocked TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString04,
|
|
mtrapargsInteger, mtrapargsString05, mtrapargsInteger02, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A door has been unlocked.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier.
|
|
The fifth argument is the door access user.
|
|
The sixth argument is the door access type."
|
|
--#TYPE "APC: Door unlocked."
|
|
--#SUMMARY "Door unlocked."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 573
|
|
|
|
apcDoorLocked TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString04,
|
|
mtrapargsInteger, mtrapargsString05, mtrapargsInteger02, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A door has been locked.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier.
|
|
The fifth argument is the door access user.
|
|
The sixth argument is the door access type."
|
|
--#TYPE "APC: Door locked."
|
|
--#SUMMARY "Door locked."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 574
|
|
|
|
apcHandleOpened TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A door handle has been opened.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: Door handle opened."
|
|
--#SUMMARY "Door handle opened."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 575
|
|
|
|
apcHandleClosed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A door handle has been closed.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: Door handle closed."
|
|
--#SUMMARY "Door handle closed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 576
|
|
|
|
|
|
apcDoorOpened TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A door has been opened.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: Door opened."
|
|
--#SUMMARY "Door opened."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 577
|
|
|
|
apcDoorClosed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A door has been closed.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: Door closed."
|
|
--#SUMMARY "Door closed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 578
|
|
|
|
-- trap number 579 available
|
|
|
|
|
|
apcKeyOverrideUnlocked TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"SEVERE: Key override unlock has occurred.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: Key override unlock has occurred."
|
|
--#SUMMARY "Key override unlock has occurred."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 580
|
|
|
|
|
|
apcKeyOverrideLocked TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Key override lock has occurred.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: Key override lock has occurred."
|
|
--#SUMMARY "Key override lock has occurred."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 581
|
|
|
|
apcForcedEntry TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"SEVERE: A forced entry condition has occurred.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: A forced entry condition has occurred."
|
|
--#SUMMARY "A forced entry has occurred."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 582
|
|
|
|
apcForcedEntryCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A forced entry condition has been cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: A forced entry condition has been cleared."
|
|
--#SUMMARY "A forced entry has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 583
|
|
|
|
|
|
apcRelockTimeout TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"SEVERE: A relock timout has occurred.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: Relock timout."
|
|
--#SUMMARY "Relock timeout."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 584
|
|
|
|
apcRelockTimeoutCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A relock timout has been cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: relock timout has been cleared."
|
|
--#SUMMARY "Relock timout has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 585
|
|
|
|
apcDoorSenseDisconnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"SEVERE: A door sensor was disconnected.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: A door sensor was disconnected."
|
|
--#SUMMARY "A door sensor was disconnected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 586
|
|
|
|
apcDoorSenseConnected TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A forced entry condition has been cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: A door sensor was connected."
|
|
--#SUMMARY "A door sensor was connected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 587
|
|
|
|
|
|
apcDoorLostComms TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"SEVERE: Communications have been lost with the door.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: A door has lost communications."
|
|
--#SUMMARY "A door has lost communications."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 588
|
|
|
|
apcDoorEstablishedComms TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communications have been established with the door.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: A door has established communications."
|
|
--#SUMMARY "A door has established communications."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 589
|
|
|
|
|
|
|
|
apcRegisteredUserAccessChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsString05, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Registered user access changed.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the user name."
|
|
--#TYPE "APC: Registered user access change."
|
|
--#SUMMARY "Registered user access change."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 590
|
|
|
|
|
|
apcUnregisteredUserStatusChange TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsString05, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Unregistered user status changed.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the user name."
|
|
--#TYPE "APC: Unregistered user status change."
|
|
--#SUMMARY "Unregistered user status change."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 591
|
|
|
|
apcDeviceClearUserConfigs TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: User configurations reset command has been issued.
|
|
The first argument is the device serial number.
|
|
The second argument is the device name.
|
|
The third argument is a secondary device id number."
|
|
--#TYPE "APC: User configurations reset command has been issued."
|
|
--#SUMMARY "User configurations reset command has been issued."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 592
|
|
|
|
-- Add more events starting at 600 for UPS Devices
|
|
|
|
upsBatteryTempSensorFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The battery temperature sensor fault exists."
|
|
--#TYPE "APC UPS: The battery temperature sensor fault exists."
|
|
--#SUMMARY "The battery temperature sensor fault exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 600
|
|
|
|
upsBatteryTempSensorFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The battery temperature sensor fault cleared."
|
|
--#TYPE "APC UPS: The battery temperature sensor fault cleared."
|
|
--#SUMMARY "The battery temperature sensor fault cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 601
|
|
|
|
upsBatterySoftBusStartFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A battery bus soft start fault exists."
|
|
--#TYPE "APC UPS: A battery bus soft start fault exists."
|
|
--#SUMMARY "A battery bus soft start fault exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 602
|
|
|
|
upsBatterySoftBusStartFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A battery bus soft start fault exists cleared."
|
|
--#TYPE "APC UPS: A battery bus soft start fault exists cleared."
|
|
--#SUMMARY "A battery bus soft start fault exists cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 603
|
|
|
|
apcOutputShortCircuit TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An output short circuit condition exists."
|
|
--#TYPE "APC Device: An output short circuit condition exists."
|
|
--#SUMMARY "An output short circuit condition exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 604
|
|
|
|
apcOutputShortCircuitCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An output short circuit condition cleared."
|
|
--#TYPE "APC Device: An output short circuit condition cleared."
|
|
--#SUMMARY "An output short circuit condition cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 605
|
|
|
|
apcOutputRelayFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An output relay (or its driver) fault exists."
|
|
--#TYPE "APC Device: An output relay (or its driver) fault exists."
|
|
--#SUMMARY "An output relay (or its driver) fault exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 606
|
|
|
|
apcOutputRelayFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An output relay (or its driver) fault cleared."
|
|
--#TYPE "APC Device: An output relay (or its driver) fault cleared."
|
|
--#SUMMARY "An output relay (or its driver) fault cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 607
|
|
|
|
upsPfcFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A PFC fault exists."
|
|
--#TYPE "APC UPS: A PFC fault exists."
|
|
--#SUMMARY "A PFC fault exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 608
|
|
|
|
upsPfcFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The PFC fault cleared."
|
|
--#TYPE "APC UPS: The PFC fault cleared."
|
|
--#SUMMARY "The PFC fault cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 609
|
|
|
|
apcDcBusOverVoltage TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The DC bus voltage is too high."
|
|
--#TYPE "APC Devcie: DC bus voltage is too high."
|
|
--#SUMMARY "The DC bus voltage is too high."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 610
|
|
|
|
apcDcBusOverVoltageCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The DC bus voltage is too high cleared."
|
|
--#TYPE "APC Device: The DC bus voltage is too high cleared."
|
|
--#SUMMARY "The DC bus voltage is too high cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 611
|
|
|
|
upsInverterFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The inverter fault exists."
|
|
--#TYPE "APC UPS: The inverter fault exists."
|
|
--#SUMMARY "The inverter fault exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 612
|
|
|
|
upsInverterFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The inverter fault cleared."
|
|
--#TYPE "APC UPS: The inverter fault cleared."
|
|
--#SUMMARY "The inverter fault cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 613
|
|
|
|
apcAdConverterFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The A/D converter fault exists."
|
|
--#TYPE "APC Device: The A/D converter fault exists."
|
|
--#SUMMARY "The A/D converter fault exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 614
|
|
|
|
apcAdConverterFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The A/D converter fault cleared."
|
|
--#TYPE "APC Device: The A/D converter fault cleared."
|
|
--#SUMMARY "The A/D converter fault cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 615
|
|
|
|
apcLogicPowerSupplyFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A logic power supply fault exists."
|
|
--#TYPE "APC Device: A logic power supply fault exists."
|
|
--#SUMMARY "A logic power supply fault exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 616
|
|
|
|
apcLogicPowerSupplyFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A logic power supply fault cleared."
|
|
--#TYPE "APC Device: A logic power supply fault cleared."
|
|
--#SUMMARY "A logic power supply fault cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 617
|
|
|
|
apcTransformerDCImbalanceFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The DC component of the transformer's current is too high."
|
|
--#TYPE "APC Device: The DC component of the tformer's curr is too high."
|
|
--#SUMMARY "The DC component of the transformer's current is too high."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 618
|
|
|
|
apcTransformerDCImbalanceFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The DC component of the transformer's current is normal."
|
|
--#TYPE "APC Device: The DC component of the tformer's curr is normal."
|
|
--#SUMMARY "The DC component of the transformer's current is normal."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 619
|
|
|
|
upsBackfeedRelayFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The backfeed relay (or its driver) has a fault."
|
|
--#TYPE "UPS Device: The backfeed relay (or its driver) has a fault."
|
|
--#SUMMARY "The backfeed relay (or its driver) has a fault."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 620
|
|
|
|
upsBackfeedRelayFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The backfeed relay (or its driver) has a fault cleared."
|
|
--#TYPE "UPS Device: The bfeed rly (or its drver) has a flt cleared."
|
|
--#SUMMARY "The backfeed relay (or its driver) has a fault cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 621
|
|
|
|
upsBypassRelayFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A bypass relay (or its driver) has a fault."
|
|
--#TYPE "APC Device: A bypass relay (or its driver) has a fault."
|
|
--#SUMMARY "A bypass relay (or its driver) has a fault."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 622
|
|
|
|
upsBypassRelayFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A bypass relay (or its driver) has a fault cleared."
|
|
--#TYPE "APC Device: A bypass relay (or its driver) has a fault cleared."
|
|
--#SUMMARY "A bypass relay (or its driver) has a fault cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 623
|
|
|
|
|
|
xPDUBranchCurrentMinAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The current in a branch circuit is outside the limits specified for that
|
|
branch circuit.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the panel position of the branch circuit (1-based index).
|
|
The fourth argument is the measured current in tenths of Amps.
|
|
The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated."
|
|
--#TYPE "APC XPDU: Branch circuit minimum current alarm."
|
|
--#SUMMARY "Branch circuit current is below threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 626
|
|
|
|
xPDUBranchCurrentMinAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a branch circuit is back within the limits
|
|
specified for that branch circuit.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the panel position of the branch circuit (1-based index).
|
|
The fourth argument is the measured current in tenths of Amps."
|
|
--#TYPE "APC XPDU: Branch circuit minimum current alarm cleared."
|
|
--#SUMMARY "Branch circuit low current alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 627
|
|
|
|
xPDUBranchCurrentMaxAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The current in a branch circuit is outside the limits specified for that
|
|
branch circuit.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the panel position of the branch circuit (1-based index).
|
|
The fourth argument is the measured current in tenths of Amps.
|
|
The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated."
|
|
--#TYPE "APC XPDU: Branch circuit maximum current alarm."
|
|
--#SUMMARY "Branch circuit current is above threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 628
|
|
|
|
xPDUBranchCurrentMaxAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
|
|
mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a branch circuit is back within the limits
|
|
specified for that branch circuit.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the panel position of the branch circuit (1-based index).
|
|
The fourth argument is the measured current in tenths of Amps."
|
|
--#TYPE "APC XPDU: Branch circuit maximum current alarm cleared."
|
|
--#SUMMARY "Branch circuit high current alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 629
|
|
|
|
|
|
rPDUOutletLowLoad TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDUOutletStatusIndex, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Rack PDU has violated the outlet low load threshold.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#TYPE "APC Rack PDU: Violation of outlet low load threshold."
|
|
--#SUMMARY "A Rack PDU has violated the outlet low load threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 630
|
|
|
|
rPDUOutletLowLoadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDUOutletStatusIndex, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The outlet low load condition on a Rack PDU has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#TYPE "APC Rack PDU: Low load condition cleared."
|
|
--#SUMMARY "The low load condition on a Rack PDU has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 631
|
|
|
|
rPDUOutletNearOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDUOutletStatusIndex, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A Rack PDU is near an outlet overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#TYPE "APC Rack PDU: Near an overload condition."
|
|
--#SUMMARY "A Rack PDU is near an outlet overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 632
|
|
|
|
rPDUOutletNearOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDUOutletStatusIndex, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The outlet near overload condition on a Rack PDU has
|
|
been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#TYPE "APC Rack PDU: Outlet Near overload condition has cleared."
|
|
--#SUMMARY "Rack PDU outlet near overload condition has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 633
|
|
|
|
rPDUOutletOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDUOutletStatusIndex, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A Rack PDU is in an overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#TYPE "APC Rack PDU: Outlet Overload condition."
|
|
--#SUMMARY "A Rack PDU is in an outlet overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 634
|
|
|
|
rPDUOutletOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
|
|
rPDUOutletStatusIndex, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The outlet overload condition on a Rack PDU has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#TYPE "APC Rack PDU: Overload condition has cleared."
|
|
--#SUMMARY "The outlet overload condition on a Rack PDU has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 635
|
|
|
|
apcTestTrap TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsInteger02, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Trap used to test SNMP trap functionality.
|
|
The first argument is a place holder for test variables."
|
|
--#TYPE "APC: Test trap."
|
|
--#SUMMARY "Test Trap."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 636
|
|
|
|
baseFanFailureCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Base module fan has been repaired"
|
|
--#TYPE "APC UPS: Base module fan has been repaired"
|
|
--#SUMMARY "The base module fan has been repaired."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 637
|
|
|
|
|
|
|
|
atsLowLoad TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
atsOutputPhaseIndex, atsOutputBank, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: ATS has violated the bank or phase low load threshold.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is the phase number
|
|
The fourth argument is the bank number. -1 is returned if bank does not exist."
|
|
--#TYPE "APC ATS: Violation of bank or phase low load threshold."
|
|
--#SUMMARY "ATS has violated the bank or phase low load threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 638
|
|
|
|
atsLowLoadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
atsOutputPhaseIndex, atsOutputBank, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The bank or phase low load condition on an ATS has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is the phase number
|
|
The fourth argument is the bank number. -1 is returned if bank does not exist."
|
|
--#TYPE "APC ATS: Low load condition cleared."
|
|
--#SUMMARY "The low load condition on an ATS has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 639
|
|
|
|
atsNearOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
atsOutputPhaseIndex, atsOutputBank, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: ATS has violated the bank or phase near overload threshold.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is the phase number
|
|
The fourth argument is the bank number. -1 is returned if bank does not exist."
|
|
--#TYPE "APC ATS: Near an overload condition."
|
|
--#SUMMARY "ATS is near a bank or phase overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 640
|
|
|
|
atsNearOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
atsOutputPhaseIndex, atsOutputBank, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The bank or phase near overload condition on an ATS has
|
|
been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is the phase number
|
|
The fourth argument is the bank number. -1 is returned if bank does not exist."
|
|
--#TYPE "APC ATS: Bank or phase near overload condition has cleared."
|
|
--#SUMMARY "ATS bank or phase near overload condition has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 641
|
|
|
|
atsOverload TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
atsOutputPhaseIndex, atsOutputBank, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: ATS is in an overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is the phase number.
|
|
The fourth argument is the bank number. -1 is returned if bank does not exist."
|
|
--#TYPE "APC ATS: Bank or Phase Overload condition."
|
|
--#SUMMARY "ATS is in overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 642
|
|
|
|
atsOverloadCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
atsOutputPhaseIndex, atsOutputBank, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The bank or phase overload condition on an ATS has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is the phase number.
|
|
The fourth argument is the bank number. -1 is returned if bank does not exist."
|
|
--#TYPE "APC ATS: Overload condition has cleared."
|
|
--#SUMMARY "The bank or phase overload condition on an ATS has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 643
|
|
|
|
atsRMSOverVoltage TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Overvoltage condition violated.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the source: 0=A, 1=B."
|
|
--#TYPE "APC ATS: Overvoltage condition violated."
|
|
--#SUMMARY "Overvoltage condition violated."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 644
|
|
|
|
atsRMSOverVoltageCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Overvoltage condition cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the source: 0=A, 1=B."
|
|
--#TYPE "APC ATS: Overvoltage condition cleared."
|
|
--#SUMMARY "Overvoltage condition cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 645
|
|
|
|
atsRMSUnderVoltage TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Undervoltage condition violated.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the source: 0=A, 1=B."
|
|
--#TYPE "APC ATS: Undervoltage condition violated."
|
|
--#SUMMARY "Undervoltage condition violated."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 646
|
|
|
|
atsRMSUnderVoltageCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Undervoltage condition cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the source: 0=A, 1=B."
|
|
--#TYPE "APC ATS: Undervoltage condition cleared."
|
|
--#SUMMARY "Undervoltage condition cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 647
|
|
|
|
atsRMSOverFrequency TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: OverFrequency condition violated.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the source: 0=A, 1=B."
|
|
--#TYPE "APC ATS: OverFrequency condition violated."
|
|
--#SUMMARY "OverFrequency condition violated."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 648
|
|
|
|
atsRMSOverFrequencyCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: OverFrequency condition cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the source: 0=A, 1=B."
|
|
--#TYPE "APC ATS: OverFrequency condition cleared."
|
|
--#SUMMARY "OverFrequency condition cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 649
|
|
|
|
atsRMSUnderFrequency TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: UnderFrequency condition violated.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the source: 0=A, 1=B."
|
|
--#TYPE "APC ATS: UnderFrequency condition violated."
|
|
--#SUMMARY "UnderFrequency condition violated."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 650
|
|
|
|
atsRMSUnderFrequencyCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: UnderFrequency condition cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the source: 0=A, 1=B."
|
|
--#TYPE "APC ATS: UnderFrequency condition cleared."
|
|
--#SUMMARY "UnderFrequency condition cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 651
|
|
|
|
|
|
|
|
-- MODULAR POWER DISTRIBUTION SYSTEM
|
|
|
|
isxModularDistributionCommLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communication with a metering segment of the modular
|
|
distribution system has been lost.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the segment number.
|
|
The fourth argument describes the modules served by this metering segment."
|
|
--#TYPE "APC MDS: Com lost in modular distribution system."
|
|
--#SUMMARY "Modular distribution communication lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 652
|
|
|
|
isxModularDistributionCommEstablished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communication with a metering segment of the modular
|
|
distribution system has been restored.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the segment number.
|
|
The fourth argument describes the modules served by this metering segment."
|
|
--#TYPE "APC MDS: Com restored in modular distribution system."
|
|
--#SUMMARY "Modular distribution communication restored."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 653
|
|
|
|
isxModularDistributionModuleInserted TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A distribution module has been inserted into the system.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module location number."
|
|
--#TYPE "APC MDS: Distribution module inserted."
|
|
--#SUMMARY "Distribution module inserted."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 654
|
|
|
|
isxModularDistributionModuleRemoved TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A distribution module has been removed from the system.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module location number."
|
|
--#TYPE "APC MDS: Distribution module removed."
|
|
--#SUMMARY "Distribution module removed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 655
|
|
|
|
isxModularBreakerOpenAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A distribution module breaker is open and in an alarm condition.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module number.
|
|
The fourth argument is the module breaker(s) (1=L1, 2=L2, 3=L3, 4=L12, 5=L23, 6=L123).
|
|
The fifth argument is the load name associated with the circuit/cable fed by this breaker."
|
|
--#TYPE "APC MDS: Distribution breaker open alarm."
|
|
--#SUMMARY "Distribution breaker open alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 656
|
|
|
|
isxModularBreakerOpenAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An alarm caused by a distribution breaker being open has been cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module number.
|
|
The fourth argument is the breaker(s) (1=L1, 2=L2, 3=L3, 4=L12, 5=L23, 6=L123).
|
|
The fifth argument is the load name associated with the circuit/cable fed by this breaker."
|
|
--#TYPE "APC MDS: Distribution breaker open alarm cleared."
|
|
--#SUMMARY "Distribution breaker open alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 657
|
|
|
|
isxModularMinCurrentThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsInteger02, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The current in a distribution module is below the minimum/critical
|
|
limit specified for the circuit/cable.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
|
|
The sixth argument is the load name associated with the circuit/cable fed by this breaker."
|
|
--#TYPE "APC MDS: Distribution minimum current alarm."
|
|
--#SUMMARY "Distribution current is below the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 658
|
|
|
|
isxModularMinCurrentThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a distribution module is no longer below the minimum/critical
|
|
limit specified for the circuit/cable.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the load name associated with the circuit/cable fed by this breaker."
|
|
--#TYPE "APC MDS: Distribution minimum current alarm cleared."
|
|
--#SUMMARY "Distribution current no longer below the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 659
|
|
|
|
isxModularLowCurrentThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsInteger02, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The current in a distribution module is below the low/warning
|
|
limit specified for the circuit/cable.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
|
|
The sixth argument is the load name associated with the circuit/cable fed by this breaker."
|
|
--#TYPE "APC MDS: Distribution low current alarm."
|
|
--#SUMMARY "Distribution current is below the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 660
|
|
|
|
isxModularLowCurrentThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a distribution module is no longer below the low/warning
|
|
limit specified for the circuit/cable.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the load name associated with the circuit/cable fed by this breaker."
|
|
--#TYPE "APC MDS: Distribution low current alarm cleared."
|
|
--#SUMMARY "Distribution current no longer below the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 661
|
|
|
|
isxModularHighCurrentThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsInteger02, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The current in a distribution module is above the high/warning
|
|
limit specified for the circuit/cable.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
|
|
The sixth argument is the load name associated with the circuit/cable fed by this breaker."
|
|
--#TYPE "APC MDS: Distribution high current alarm."
|
|
--#SUMMARY "Distribution current is above the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 662
|
|
|
|
isxModularHighCurrentThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a distribution module is no longer above the high/warning
|
|
limit specified for the circuit/cable.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the load name associated with the circuit/cable fed by this breaker."
|
|
--#TYPE "APC MDS: Distribution high current alarm cleared."
|
|
--#SUMMARY "Distribution current no longer above the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 663
|
|
|
|
isxModularMaxCurrentThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsInteger02, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The current in a distribution module is above the maximum/critical
|
|
limit specified for the circuit/cable.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
|
|
The sixth argument is the load name associated with the circuit/cable fed by this breaker."
|
|
--#TYPE "APC MDS: Distribution maximum current alarm."
|
|
--#SUMMARY "Distribution current is above the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 664
|
|
|
|
isxModularMaxCurrentThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a distribution module is no longer above the maximum/critical
|
|
limit specified for the circuit/cable.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the module number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the load name associated with the circuit/cable fed by this breaker."
|
|
--#TYPE "APC MDS: Distribution maximum current alarm cleared."
|
|
--#SUMMARY "Distribution current no longer above the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 665
|
|
|
|
isxModularSubfeedBreakerOpenAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A distribution subfeed breaker is open and in an alarm condition.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the subfeed number.
|
|
The fourth argument is the load name associated with the subfeed."
|
|
--#TYPE "APC MDS: Distribution subfeed breaker open alarm."
|
|
--#SUMMARY "Distribution subfeed breaker open alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 666
|
|
|
|
isxModularSubfeedBreakerOpenAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An alarm caused by a distribution subfeed breaker being open has been cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the subfeed number.
|
|
The fourth argument is the load name associated with the subfeed."
|
|
--#TYPE "APC MDS: Distribution subfeed breaker open alarm cleared."
|
|
--#SUMMARY "Distribution subfeed breaker open alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 667
|
|
|
|
isxModularSubfeedMinCurrentThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsInteger02, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The current in a distribution subfeed is below the minimum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the subfeed number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
|
|
The sixth argument is the load name associated with the subfeed."
|
|
--#TYPE "APC MDS: Distribution subfeed minimum current alarm."
|
|
--#SUMMARY "Distribution subfeed current is below the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 668
|
|
|
|
isxModularSubfeedMinCurrentThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a distribution subfeed is no longer below the minimum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the subfeed number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the load name associated with the subfeed."
|
|
--#TYPE "APC MDS: Distribution subfeed minimum current alarm cleared."
|
|
--#SUMMARY "Distribution subfeed current no longer below the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 669
|
|
|
|
isxModularSubfeedLowCurrentThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsInteger02, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The current in a distribution subfeed is below the low/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the subfeed number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
|
|
The sixth argument is the load name associated with the subfeed."
|
|
--#TYPE "APC MDS: Distribution subfeed low current alarm."
|
|
--#SUMMARY "Distribution subfeed current is below the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 670
|
|
|
|
isxModularSubfeedLowCurrentThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a distribution subfeed is no longer below the low/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the subfeed number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the load name associated with the subfeed."
|
|
--#TYPE "APC MDS: Distribution subfeed low current alarm cleared."
|
|
--#SUMMARY "Distribution subfeed current is no longer below the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 671
|
|
|
|
isxModularSubfeedHighCurrentThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsInteger02, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The current in a distribution subfeed is above the high/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the subfeed number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
|
|
The sixth argument is the load name associated with the subfeed."
|
|
--#TYPE "APC MDS: Distribution subfeed high current alarm."
|
|
--#SUMMARY "Distribution subfeed current is above the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 672
|
|
|
|
isxModularSubfeedHighCurrentThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a distribution subfeed is no longer above the high/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the subfeed number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the load name associated with the subfeed."
|
|
--#TYPE "APC MDS: Distribution subfeed high current alarm cleared."
|
|
--#SUMMARY "Distribution subfeed current no longer above the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 673
|
|
|
|
isxModularSubfeedMaxCurrentThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsInteger02, mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The current in a distribution subfeed is above the maximum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the subfeed number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
|
|
The sixth argument is the load name associated with the subfeed."
|
|
--#TYPE "APC MDS: Distribution subfeed maximum current alarm."
|
|
--#SUMMARY "Distribution subfeed current is above the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 674
|
|
|
|
isxModularSubfeedMaxCurrentThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger03,
|
|
mtrapargsString04, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The current in a distribution subfeed is no longer above the maximum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the subfeed number.
|
|
The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3).
|
|
The fifth argument is the load name associated with the subfeed."
|
|
--#TYPE "APC MDS: Distribution subfeed maximum current alarm cleared."
|
|
--#SUMMARY "Distribution subfeed current no longer above the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 675
|
|
|
|
isxModularTotalOutputCurrentMinThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The total output current of the distribution is below the minimum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated."
|
|
--#TYPE "APC MDS: Total distribution output minimum current alarm."
|
|
--#SUMMARY "Distribution total current is below the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 676
|
|
|
|
isxModularTotalOutputCurrentMinThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The total output current of the distribution is no longer below the minimum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3)."
|
|
--#TYPE "APC MDS: Total output minimum current alarm cleared."
|
|
--#SUMMARY "Distribution total current no longer below the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 677
|
|
|
|
isxModularTotalOutputCurrentLowThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The total output current of the distribution is below the low/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated."
|
|
--#TYPE "APC MDS: Total output low current alarm."
|
|
--#SUMMARY "Distribution total current is below the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 678
|
|
|
|
isxModularTotalOutputCurrentLowThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The total output current of the distribution is no longer below the low/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3)."
|
|
--#TYPE "APC MDS: Total output low current alarm cleared."
|
|
--#SUMMARY "Distribution total current no longer below the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 679
|
|
|
|
isxModularTotalOutputCurrentHighThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The total output current of the distribution is above the high/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated."
|
|
--#TYPE "APC MDS: Total output high current alarm."
|
|
--#SUMMARY "Distribution total current is above the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 680
|
|
|
|
isxModularTotalOutputCurrentHighThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The total output current of the distribution is no longer above the high/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3)."
|
|
--#TYPE "APC MDS: Total output high current alarm cleared."
|
|
--#SUMMARY "Distribution total current no longer above the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 681
|
|
|
|
isxModularTotalOutputCurrentMaxThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The total output current of the distribution is above the maximum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated."
|
|
--#TYPE "APC MDS: Total output maximum current alarm."
|
|
--#SUMMARY "Distribution total current is above the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 682
|
|
|
|
isxModularTotalOutputCurrentMaxThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The total output current of the distribution is no longer above the maximum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3)."
|
|
--#TYPE "APC MDS: Total output maximum current alarm cleared."
|
|
--#SUMMARY "Distribution total current no longer above the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 683
|
|
|
|
isxModularOutputVoltageMinThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The distribution output voltage is below the minimum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated."
|
|
--#TYPE "APC MDS: Distribution minimum output voltage alarm."
|
|
--#SUMMARY "Distribution output voltage is below the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 684
|
|
|
|
isxModularOutputVoltageMinThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The distribution output voltage is no longer below the minimum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3)."
|
|
--#TYPE "APC MDS: Distribution minimum output voltage alarm cleared."
|
|
--#SUMMARY "Distribution output voltage no longer below the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 685
|
|
|
|
isxModularOutputVoltageLowThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The distribution output voltage is below the low/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated."
|
|
--#TYPE "APC MDS: Distribution low output voltage alarm."
|
|
--#SUMMARY "Distribution output voltage is below the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 686
|
|
|
|
isxModularOutputVoltageLowThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The distribution output voltage is no longer below the low/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3)."
|
|
--#TYPE "APC MDS: Distribution low output voltage alarm cleared."
|
|
--#SUMMARY "Distribution output voltage no longer below the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 687
|
|
|
|
isxModularOutputVoltageHighThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The distribution output voltage is above the high/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated."
|
|
--#TYPE "APC MDS: Distribution high output voltage alarm."
|
|
--#SUMMARY "Distribution output voltage is above the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 688
|
|
|
|
isxModularOutputVoltageHighThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The distribution output voltage is no longer above the high/warning limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3)."
|
|
--#TYPE "APC MDS: Distribution high output voltage alarm cleared."
|
|
--#SUMMARY "Distribution output voltage no longer above the warning threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 689
|
|
|
|
isxModularOutputVoltageMaxThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The distribution output voltage is above the maximum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3).
|
|
The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated."
|
|
--#TYPE "APC MDS: Distribution maximum output voltage alarm."
|
|
--#SUMMARY "Distribution output voltage is above the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 690
|
|
|
|
isxModularOutputVoltageMaxThresholdViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The distribution output voltage is no longer above the maximum/critical limit specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the phase index (1=L1, 2=L2, 3=L3)."
|
|
--#TYPE "APC MDS: Distribution maximum output voltage alarm cleared."
|
|
--#SUMMARY "Distribution output voltage no longer above the critical threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 691
|
|
|
|
apcDoorClosedImproperly TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"SEVERE: A door has been closed improperly.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: Door closed improperly."
|
|
--#SUMMARY "Door closed improperly."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 692
|
|
|
|
apcDoorClosedImproperlyCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A door is no longer closed improperly.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: Door no longer closed improperly."
|
|
--#SUMMARY "Door no longer closed improperly."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 693
|
|
|
|
apcUserScheduleViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"SEVERE: A user has had a door opened past the scheduled access period.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: User schedule violated."
|
|
--#SUMMARY "User schedule violated."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 694
|
|
|
|
apcUserScheduleViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03,
|
|
mtrapargsString04, mtrapargsInteger, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: User schedule violation has been cleared.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the host device location.
|
|
The fourth argument is the door identifier, (1=front, 2=rear)."
|
|
--#TYPE "APC: User schedule violation cleared."
|
|
--#SUMMARY "User schedule violation cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 695
|
|
|
|
isxModularOutputFrequencyThresholdViolation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The distribution output frequency is outside of the operating range specified.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the threshold, in tenths of Hertz, from which the alarm was generated."
|
|
--#TYPE "APC MDS: Distribution output frequency out of range."
|
|
--#SUMMARY "Distribution output frequency out of range."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 696
|
|
|
|
isxModularOutputFrequencyViolationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The distribution output frequency is no longer out of range.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC MDS: Distribution output frequency no longer out of range."
|
|
--#SUMMARY "Distribution output frequency no longer out of range."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 697
|
|
|
|
atsSourceStatusFail TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: ATS Source failed.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the source: 0=A, 1=B."
|
|
--#TYPE "APC ATS: ATS Source failed."
|
|
--#SUMMARY "ATS Source failed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 698
|
|
|
|
atsSourceStatusOk TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: ATS Source OK.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the source: 0=A, 1=B."
|
|
--#TYPE "APC ATS: ATS Source OK."
|
|
--#SUMMARY "ATS Source OK."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 699
|
|
|
|
atsHardwareStatusFail TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: ATS display board hardware failed.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the failed hardware:
|
|
0= Phase LEDs/Push-button hardware failure
|
|
1= Seven-segment display hardware failure."
|
|
--#TYPE "APC ATS: ATS display board hardware failed."
|
|
--#SUMMARY "ATS display board hardware failed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 700
|
|
|
|
atsHardwareStatusOk TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { atsIdentSerialNumber, atsConfigProductName,
|
|
mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: ATS display board hardware ok.
|
|
The first argument is the serial number.
|
|
The second argument is the product name.
|
|
The third argument is an integer representing the hardware:
|
|
0= Phase LEDs/Push-button hardware failure
|
|
1= Seven-segment display hardware failure."
|
|
--#TYPE "APC ATS: ATS display board hardware ok."
|
|
--#SUMMARY "ATS display board hardware ok."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 701
|
|
|
|
atsControllerRestart TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: ATS Controller restarted."
|
|
--#TYPE "APC ATS: ATS Controller restarted."
|
|
--#SUMMARY "ATS Controller restarted."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 702
|
|
|
|
|
|
|
|
|
|
xATSS1BadPhaseRotation TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The device's source 1 phase rotation is bad.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: S1 bad phase rotation alarm."
|
|
--#SUMMARY "Phase rotation on source 1 is bad."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 724
|
|
|
|
xATSS1BadPhaseRotationCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The device's source 1 phase rotation is back to normal.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: S1 phase rotation back to normal."
|
|
--#SUMMARY "S1 phase rotation back to normal."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 725
|
|
|
|
xATSS1BadPhaseBalance TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
|
|
mtrapargsString}
|
|
DESCRIPTION
|
|
"SEVERE: The device's source 1 phase balance is out of bounds.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the minimum phase balance as a percentage."
|
|
--#TYPE "APC XATS: S1 phase imbalance exceeds threshold alarm."
|
|
--#SUMMARY "Phase imbalance on source 1 exceeds threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 726
|
|
|
|
xATSS1BadPhaseBalanceCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString}
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The device's source 1 phase balance is back to normal.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC XATS: S1 phase balance back to normal."
|
|
--#SUMMARY "S1 phase balance back to normal."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 727
|
|
|
|
isxModularTransformerOverheating TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The distribution transformer temperature is too hot.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC MDS: Transformer overheating."
|
|
--#SUMMARY "Distribution transformer temperature is too hot."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 728
|
|
|
|
isxModularTransformerOverheatingCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The distribution transformer temperature has returned to normal.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC MDS: Transformer temperature has returned to normal."
|
|
--#SUMMARY "Distribution transformer temperature has returned to normal."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 729
|
|
|
|
apcInternalCommunicationFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: An internal UPS communication fault exists."
|
|
--#TYPE "APC Device: An internal UPS communication fault exists."
|
|
--#SUMMARY "An internal UPS communication fault exists."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 730
|
|
|
|
apcInternalCommunicationFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An internal UPS communication fault no longer exists."
|
|
--#TYPE "APC Device:An internal UPS communication fault no longer exists."
|
|
--#SUMMARY "An internal UPS communication fault no longer exists."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 731
|
|
|
|
upsOutletGroupCommand TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { upsOutletGroupControlIndex, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: The specified Outlet Group command has been issued."
|
|
--#TYPE "APC UPS: Outlet Group command issued."
|
|
--#SUMMARY "Outlet Group command issued."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 732
|
|
|
|
onbatterycommunicationLost TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Communication to the UPS when the UPS is on Battery. Steps
|
|
to reestablish communication are in progress."
|
|
--#TYPE "APC UPS: Communication lost"
|
|
--#SUMMARY "Communication lost between the agent and the UPS when UPS is on Battery."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 733
|
|
|
|
upsCriticalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A UPS critical condition was detected.
|
|
The first variable is the error condition text message.
|
|
The second variable is the error number."
|
|
--#TYPE "UPS: A critical condition has been detected."
|
|
--#SUMMARY "A critical condition has been detected."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 734
|
|
|
|
upsCriticalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A UPS critical condition has been cleared.
|
|
The first variable is the fault condition."
|
|
--#TYPE "UPS: A critical condition has been cleared."
|
|
--#SUMMARY "A critical condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 735
|
|
|
|
upsWarningCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A UPS warning condition has been detected.
|
|
The first variable is the fault condition."
|
|
--#TYPE "UPS: A warning condition has been detected."
|
|
--#SUMMARY "A warning condition has been detected."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 736
|
|
|
|
upsWarningConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A UPS warning condition has been cleared.
|
|
The first variable is the fault condition."
|
|
--#TYPE "UPS: A warning condition has been cleared."
|
|
--#SUMMARY "A warning condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 737
|
|
|
|
upsInformationalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A UPS informational condition has been detected.
|
|
The first variable is the fault condition."
|
|
--#TYPE "UPS: Informational condition detected."
|
|
--#SUMMARY "An informational condition has been detected."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 738
|
|
|
|
upsInformationalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A UPS informational condition has been cleared.
|
|
The first variable is the fault condition."
|
|
--#TYPE "UPS: Informational condition cleared."
|
|
--#SUMMARY "An informational condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 739
|
|
|
|
isxcInformationalAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02,
|
|
mtrapargsOctetString,
|
|
mtrapargsInteger,
|
|
mtrapargsString03,
|
|
mtrapargsOctetString02,
|
|
mtrapargsString04,
|
|
mtrapargsOctetString03,
|
|
mtrapargsString05,
|
|
mtrapargsString06,
|
|
mtrapargsString07,
|
|
mtrapargsOctetString04,
|
|
mtrapargsOctetString05,
|
|
mtrapargsString08,
|
|
mtrapargsOctetString06,
|
|
mtrapargsOctetString07,
|
|
mtrapargsInteger02,
|
|
mtrapargsInteger03,
|
|
mtrapargsOctetString08,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An ISXC Alarm exists.
|
|
The first argument is the unique ISXC alarm ID.
|
|
The second argument is the ISXC alarm label as a UTF8 string.
|
|
The third argument is the ISXC alarm code.
|
|
The fourth argument is the unique ISXC device ID.
|
|
The fifth argument is the ISXC device label as a UTF8 string.
|
|
The sixth argument is the ISXC parent host.
|
|
The seventh argument is the ISXC device type as a UTF8 string.
|
|
The eighth argument is the device serial number.
|
|
The ninth argument is the device model number.
|
|
The tenth argument is the device host.
|
|
The eleventh argument is the device location as a UTF8 string.
|
|
The twelfth argument is the device contact as a UTF8 string.
|
|
The thirteenth argument is the unique ISXC sensor ID.
|
|
The fourteenth argument is the ISXC sensor label as a UTF8 string.
|
|
The fifteenth argument is the sensor value as a UTF8 string.
|
|
The sixteenth argument is the ISXC alarm start time.
|
|
The seventeenth argument is the ISXC alarm resolution time.
|
|
The eighteenth argument is the description as a UTF8 string."
|
|
--#TYPE "APC ISXC: An ISXC Informational Alarm exists."
|
|
--#SUMMARY "An ISXC Informational Alarm exists."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 740
|
|
|
|
isxcInformationalAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02,
|
|
mtrapargsOctetString,
|
|
mtrapargsInteger,
|
|
mtrapargsString03,
|
|
mtrapargsOctetString02,
|
|
mtrapargsString04,
|
|
mtrapargsOctetString03,
|
|
mtrapargsString05,
|
|
mtrapargsString06,
|
|
mtrapargsString07,
|
|
mtrapargsOctetString04,
|
|
mtrapargsOctetString05,
|
|
mtrapargsString08,
|
|
mtrapargsOctetString06,
|
|
mtrapargsOctetString07,
|
|
mtrapargsInteger02,
|
|
mtrapargsInteger03,
|
|
mtrapargsOctetString08,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An ISXC Alarm has been cleared.
|
|
The first argument is the unique ISXC alarm ID.
|
|
The second argument is the ISXC alarm label as a UTF8 string.
|
|
The third argument is the ISXC alarm code.
|
|
The fourth argument is the unique ISXC device ID.
|
|
The fifth argument is the ISXC device label as a UTF8 string.
|
|
The sixth argument is the ISXC parent host.
|
|
The seventh argument is the ISXC device type as a UTF8 string.
|
|
The eighth argument is the device serial number.
|
|
The ninth argument is the device model number.
|
|
The tenth argument is the device host.
|
|
The eleventh argument is the device location as a UTF8 string.
|
|
The twelfth argument is the device contact as a UTF8 string.
|
|
The thirteenth argument is the unique ISXC sensor ID.
|
|
The fourteenth argument is the ISXC sensor label as a UTF8 string.
|
|
The fifteenth argument is the sensor value as a UTF8 string.
|
|
The sixteenth argument is the ISXC alarm start time.
|
|
The seventeenth argument is the ISXC alarm resolution time.
|
|
The eighteenth argument is the description as a UTF8 string."
|
|
--#TYPE "APC ISXC: An ISXC Informational Alarm has been cleared."
|
|
--#SUMMARY "An ISXC Informational Alarm has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 741
|
|
|
|
isxcWarningAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02,
|
|
mtrapargsOctetString,
|
|
mtrapargsInteger,
|
|
mtrapargsString03,
|
|
mtrapargsOctetString02,
|
|
mtrapargsString04,
|
|
mtrapargsOctetString03,
|
|
mtrapargsString05,
|
|
mtrapargsString06,
|
|
mtrapargsString07,
|
|
mtrapargsOctetString04,
|
|
mtrapargsOctetString05,
|
|
mtrapargsString08,
|
|
mtrapargsOctetString06,
|
|
mtrapargsOctetString07,
|
|
mtrapargsInteger02,
|
|
mtrapargsInteger03,
|
|
mtrapargsOctetString08,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An ISXC Alarm exists.
|
|
The first argument is the unique ISXC alarm ID.
|
|
The second argument is the ISXC alarm label as a UTF8 string.
|
|
The third argument is the ISXC alarm code.
|
|
The fourth argument is the unique ISXC device ID.
|
|
The fifth argument is the ISXC device label as a UTF8 string.
|
|
The sixth argument is the ISXC parent host.
|
|
The seventh argument is the ISXC device type as a UTF8 string.
|
|
The eighth argument is the device serial number.
|
|
The ninth argument is the device model number.
|
|
The tenth argument is the device host.
|
|
The eleventh argument is the device location as a UTF8 string.
|
|
The twelfth argument is the device contact as a UTF8 string.
|
|
The thirteenth argument is the unique ISXC sensor ID.
|
|
The fourteenth argument is the ISXC sensor label as a UTF8 string.
|
|
The fifteenth argument is the sensor value as a UTF8 string.
|
|
The sixteenth argument is the ISXC alarm start time.
|
|
The seventeenth argument is the ISXC alarm resolution time.
|
|
The eighteenth argument is the description as a UTF8 string."
|
|
--#TYPE "APC ISXC: An ISXC Warning Alarm exists."
|
|
--#SUMMARY "An ISXC Warning Alarm exists."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 742
|
|
|
|
isxcWarningAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02,
|
|
mtrapargsOctetString,
|
|
mtrapargsInteger,
|
|
mtrapargsString03,
|
|
mtrapargsOctetString02,
|
|
mtrapargsString04,
|
|
mtrapargsOctetString03,
|
|
mtrapargsString05,
|
|
mtrapargsString06,
|
|
mtrapargsString07,
|
|
mtrapargsOctetString04,
|
|
mtrapargsOctetString05,
|
|
mtrapargsString08,
|
|
mtrapargsOctetString06,
|
|
mtrapargsOctetString07,
|
|
mtrapargsInteger02,
|
|
mtrapargsInteger03,
|
|
mtrapargsOctetString08,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: An ISXC Alarm has been cleared.
|
|
The first argument is the unique ISXC alarm ID.
|
|
The second argument is the ISXC alarm label as a UTF8 string.
|
|
The third argument is the ISXC alarm code.
|
|
The fourth argument is the unique ISXC device ID.
|
|
The fifth argument is the ISXC device label as a UTF8 string.
|
|
The sixth argument is the ISXC parent host.
|
|
The seventh argument is the ISXC device type as a UTF8 string.
|
|
The eighth argument is the device serial number.
|
|
The ninth argument is the device model number.
|
|
The tenth argument is the device host.
|
|
The eleventh argument is the device location as a UTF8 string.
|
|
The twelfth argument is the device contact as a UTF8 string.
|
|
The thirteenth argument is the unique ISXC sensor ID.
|
|
The fourteenth argument is the ISXC sensor label as a UTF8 string.
|
|
The fifteenth argument is the sensor value as a UTF8 string.
|
|
The sixteenth argument is the ISXC alarm start time.
|
|
The seventeenth argument is the ISXC alarm resolution time.
|
|
The eighteenth argument is the description as a UTF8 string."
|
|
--#TYPE "APC ISXC: An ISXC Warning Alarm has been cleared."
|
|
--#SUMMARY "An ISXC Warning Alarm has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 743
|
|
|
|
isxcErrorAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02,
|
|
mtrapargsOctetString,
|
|
mtrapargsInteger,
|
|
mtrapargsString03,
|
|
mtrapargsOctetString02,
|
|
mtrapargsString04,
|
|
mtrapargsOctetString03,
|
|
mtrapargsString05,
|
|
mtrapargsString06,
|
|
mtrapargsString07,
|
|
mtrapargsOctetString04,
|
|
mtrapargsOctetString05,
|
|
mtrapargsString08,
|
|
mtrapargsOctetString06,
|
|
mtrapargsOctetString07,
|
|
mtrapargsInteger02,
|
|
mtrapargsInteger03,
|
|
mtrapargsOctetString08,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"ERROR: An ISXC Alarm exists.
|
|
The first argument is the unique ISXC alarm ID.
|
|
The second argument is the ISXC alarm label as a UTF8 string.
|
|
The third argument is the ISXC alarm code.
|
|
The fourth argument is the unique ISXC device ID.
|
|
The fifth argument is the ISXC device label as a UTF8 string.
|
|
The sixth argument is the ISXC parent host.
|
|
The seventh argument is the ISXC device type as a UTF8 string.
|
|
The eighth argument is the device serial number.
|
|
The ninth argument is the device model number.
|
|
The tenth argument is the device host.
|
|
The eleventh argument is the device location as a UTF8 string.
|
|
The twelfth argument is the device contact as a UTF8 string.
|
|
The thirteenth argument is the unique ISXC sensor ID.
|
|
The fourteenth argument is the ISXC sensor label as a UTF8 string.
|
|
The fifteenth argument is the sensor value as a UTF8 string.
|
|
The sixteenth argument is the ISXC alarm start time.
|
|
The seventeenth argument is the ISXC alarm resolution time.
|
|
The eighteenth argument is the description as a UTF8 string."
|
|
--#TYPE "APC ISXC: An ISXC Error Alarm exists."
|
|
--#SUMMARY "An ISXC Error Alarm exists."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 744
|
|
|
|
isxcErrorAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02,
|
|
mtrapargsOctetString,
|
|
mtrapargsInteger,
|
|
mtrapargsString03,
|
|
mtrapargsOctetString02,
|
|
mtrapargsString04,
|
|
mtrapargsOctetString03,
|
|
mtrapargsString05,
|
|
mtrapargsString06,
|
|
mtrapargsString07,
|
|
mtrapargsOctetString04,
|
|
mtrapargsOctetString05,
|
|
mtrapargsString08,
|
|
mtrapargsOctetString06,
|
|
mtrapargsOctetString07,
|
|
mtrapargsInteger02,
|
|
mtrapargsInteger03,
|
|
mtrapargsOctetString08,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"ERROR: An ISXC Alarm has been cleared.
|
|
The first argument is the unique ISXC alarm ID.
|
|
The second argument is the ISXC alarm label as a UTF8 string.
|
|
The third argument is the ISXC alarm code.
|
|
The fourth argument is the unique ISXC device ID.
|
|
The fifth argument is the ISXC device label as a UTF8 string.
|
|
The sixth argument is the ISXC parent host.
|
|
The seventh argument is the ISXC device type as a UTF8 string.
|
|
The eighth argument is the device serial number.
|
|
The ninth argument is the device model number.
|
|
The tenth argument is the device host.
|
|
The eleventh argument is the device location as a UTF8 string.
|
|
The twelfth argument is the device contact as a UTF8 string.
|
|
The thirteenth argument is the unique ISXC sensor ID.
|
|
The fourteenth argument is the ISXC sensor label as a UTF8 string.
|
|
The fifteenth argument is the sensor value as a UTF8 string.
|
|
The sixteenth argument is the ISXC alarm start time.
|
|
The seventeenth argument is the ISXC alarm resolution time.
|
|
The eighteenth argument is the description as a UTF8 string."
|
|
--#TYPE "APC ISXC: An ISXC Error Alarm has been cleared."
|
|
--#SUMMARY "An ISXC Error Alarm has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 745
|
|
|
|
isxcCriticalAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02,
|
|
mtrapargsOctetString,
|
|
mtrapargsInteger,
|
|
mtrapargsString03,
|
|
mtrapargsOctetString02,
|
|
mtrapargsString04,
|
|
mtrapargsOctetString03,
|
|
mtrapargsString05,
|
|
mtrapargsString06,
|
|
mtrapargsString07,
|
|
mtrapargsOctetString04,
|
|
mtrapargsOctetString05,
|
|
mtrapargsString08,
|
|
mtrapargsOctetString06,
|
|
mtrapargsOctetString07,
|
|
mtrapargsInteger02,
|
|
mtrapargsInteger03,
|
|
mtrapargsOctetString08,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"CRITICAL: An ISXC Alarm exists.
|
|
The first argument is the unique ISXC alarm ID.
|
|
The second argument is the ISXC alarm label as a UTF8 string.
|
|
The third argument is the ISXC alarm code.
|
|
The fourth argument is the unique ISXC device ID.
|
|
The fifth argument is the ISXC device label as a UTF8 string.
|
|
The sixth argument is the ISXC parent host.
|
|
The seventh argument is the ISXC device type as a UTF8 string.
|
|
The eighth argument is the device serial number.
|
|
The ninth argument is the device model number.
|
|
The tenth argument is the device host.
|
|
The eleventh argument is the device location as a UTF8 string.
|
|
The twelfth argument is the device contact as a UTF8 string.
|
|
The thirteenth argument is the unique ISXC sensor ID.
|
|
The fourteenth argument is the ISXC sensor label as a UTF8 string.
|
|
The fifteenth argument is the sensor value as a UTF8 string.
|
|
The sixteenth argument is the ISXC alarm start time.
|
|
The seventeenth argument is the ISXC alarm resolution time.
|
|
The eighteenth argument is the description as a UTF8 string."
|
|
--#TYPE "APC ISXC: An ISXC Critical Alarm exists."
|
|
--#SUMMARY "An ISXC Critical Alarm exists."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 746
|
|
|
|
isxcCriticalAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02,
|
|
mtrapargsOctetString,
|
|
mtrapargsInteger,
|
|
mtrapargsString03,
|
|
mtrapargsOctetString02,
|
|
mtrapargsString04,
|
|
mtrapargsOctetString03,
|
|
mtrapargsString05,
|
|
mtrapargsString06,
|
|
mtrapargsString07,
|
|
mtrapargsOctetString04,
|
|
mtrapargsOctetString05,
|
|
mtrapargsString08,
|
|
mtrapargsOctetString06,
|
|
mtrapargsOctetString07,
|
|
mtrapargsInteger02,
|
|
mtrapargsInteger03,
|
|
mtrapargsOctetString08,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"CRITICAL: An ISXC Alarm has been cleared.
|
|
The first argument is the unique ISXC alarm ID.
|
|
The second argument is the ISXC alarm label as a UTF8 string.
|
|
The third argument is the ISXC alarm code.
|
|
The fourth argument is the unique ISXC device ID.
|
|
The fifth argument is the ISXC device label as a UTF8 string.
|
|
The sixth argument is the ISXC parent host.
|
|
The seventh argument is the ISXC device type as a UTF8 string.
|
|
The eighth argument is the device serial number.
|
|
The ninth argument is the device model number.
|
|
The tenth argument is the device host.
|
|
The eleventh argument is the device location as a UTF8 string.
|
|
The twelfth argument is the device contact as a UTF8 string.
|
|
The thirteenth argument is the unique ISXC sensor ID.
|
|
The fourteenth argument is the ISXC sensor label as a UTF8 string.
|
|
The fifteenth argument is the sensor value as a UTF8 string.
|
|
The sixteenth argument is the ISXC alarm start time.
|
|
The seventeenth argument is the ISXC alarm resolution time.
|
|
The eighteenth argument is the description as a UTF8 string."
|
|
--#TYPE "APC ISXC: An ISXC Critical Alarm has been cleared."
|
|
--#SUMMARY "An ISXC Critical Alarm has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 747
|
|
|
|
isxcFailureAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02,
|
|
mtrapargsOctetString,
|
|
mtrapargsInteger,
|
|
mtrapargsString03,
|
|
mtrapargsOctetString02,
|
|
mtrapargsString04,
|
|
mtrapargsOctetString03,
|
|
mtrapargsString05,
|
|
mtrapargsString06,
|
|
mtrapargsString07,
|
|
mtrapargsOctetString04,
|
|
mtrapargsOctetString05,
|
|
mtrapargsString08,
|
|
mtrapargsOctetString06,
|
|
mtrapargsOctetString07,
|
|
mtrapargsInteger02,
|
|
mtrapargsInteger03,
|
|
mtrapargsOctetString08,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"FAILURE: An ISXC Alarm exists.
|
|
The first argument is the unique ISXC alarm ID.
|
|
The second argument is the ISXC alarm label as a UTF8 string.
|
|
The third argument is the ISXC alarm code.
|
|
The fourth argument is the unique ISXC device ID.
|
|
The fifth argument is the ISXC device label as a UTF8 string.
|
|
The sixth argument is the ISXC parent host.
|
|
The seventh argument is the ISXC device type as a UTF8 string.
|
|
The eighth argument is the device serial number.
|
|
The ninth argument is the device model number.
|
|
The tenth argument is the device host.
|
|
The eleventh argument is the device location as a UTF8 string.
|
|
The twelfth argument is the device contact as a UTF8 string.
|
|
The thirteenth argument is the unique ISXC sensor ID.
|
|
The fourteenth argument is the ISXC sensor label as a UTF8 string.
|
|
The fifteenth argument is the sensor value as a UTF8 string.
|
|
The sixteenth argument is the ISXC alarm start time.
|
|
The seventeenth argument is the ISXC alarm resolution time.
|
|
The eighteenth argument is the description as a UTF8 string."
|
|
--#TYPE "APC ISXC: An ISXC Failure Alarm exists."
|
|
--#SUMMARY "An ISXC Failure Alarm exists."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 748
|
|
|
|
isxcFailureAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02,
|
|
mtrapargsOctetString,
|
|
mtrapargsInteger,
|
|
mtrapargsString03,
|
|
mtrapargsOctetString02,
|
|
mtrapargsString04,
|
|
mtrapargsOctetString03,
|
|
mtrapargsString05,
|
|
mtrapargsString06,
|
|
mtrapargsString07,
|
|
mtrapargsOctetString04,
|
|
mtrapargsOctetString05,
|
|
mtrapargsString08,
|
|
mtrapargsOctetString06,
|
|
mtrapargsOctetString07,
|
|
mtrapargsInteger02,
|
|
mtrapargsInteger03,
|
|
mtrapargsOctetString08,
|
|
mtrapargsString }
|
|
DESCRIPTION
|
|
"FAILURE: An ISXC Alarm has been cleared.
|
|
The first argument is the unique ISXC alarm ID.
|
|
The second argument is the ISXC alarm label as a UTF8 string.
|
|
The third argument is the ISXC alarm code.
|
|
The fourth argument is the unique ISXC device ID.
|
|
The fifth argument is the ISXC device label as a UTF8 string.
|
|
The sixth argument is the ISXC parent host.
|
|
The seventh argument is the ISXC device type as a UTF8 string.
|
|
The eighth argument is the device serial number.
|
|
The ninth argument is the device model number.
|
|
The tenth argument is the device host.
|
|
The eleventh argument is the device location as a UTF8 string.
|
|
The twelfth argument is the device contact as a UTF8 string.
|
|
The thirteenth argument is the unique ISXC sensor ID.
|
|
The fourteenth argument is the ISXC sensor label as a UTF8 string.
|
|
The fifteenth argument is the sensor value as a UTF8 string.
|
|
The sixteenth argument is the ISXC alarm start time.
|
|
The seventeenth argument is the ISXC alarm resolution time.
|
|
The eighteenth argument is the description as a UTF8 string."
|
|
--#TYPE "APC ISXC: An ISXC Failure Alarm has been cleared."
|
|
--#SUMMARY "An ISXC Failure Alarm has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 749
|
|
|
|
-- rPDU2g Trap Section
|
|
|
|
rpduCriticalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A RPDU critical condition has been detected.
|
|
The first variable is the serial number.
|
|
The second variable is the device name.
|
|
The third variable is the error number.
|
|
The fourth variable is the device number.
|
|
The fifth variable is the instance number.
|
|
The sixth variable is the trap text message."
|
|
--#TYPE "RPDU: A critical condition has been detected."
|
|
--#SUMMARY "A critical condition has been detected."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 750
|
|
|
|
rpduCriticalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A RPDU critical condition has been cleared.
|
|
The first variable is the serial number.
|
|
The second variable is the device name.
|
|
The third variable is the error number.
|
|
The fourth variable is the device number.
|
|
The fifth variable is the instance number.
|
|
The sixth variable is the trap text message."
|
|
--#TYPE "RPDU: A critical condition has been cleared."
|
|
--#SUMMARY "A critical condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 751
|
|
|
|
rpduWarningCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A RPDU warning condition has been detected.
|
|
The first variable is the serial number.
|
|
The second variable is the device name.
|
|
The third variable is the error number.
|
|
The fourth variable is the device number.
|
|
The fifth variable is the instance number.
|
|
The sixth variable is the trap text message."
|
|
--#TYPE "RPDU: A warning condition has been detected."
|
|
--#SUMMARY "A warning condition has been detected."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 752
|
|
|
|
rpduWarningConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A RPDU warning condition has been cleared.
|
|
The first variable is the serial number.
|
|
The second variable is the device name.
|
|
The third variable is the error number.
|
|
The fourth variable is the device number.
|
|
The fifth variable is the instance number.
|
|
The sixth variable is the trap text message."
|
|
--#TYPE "RPDU: A warning condition has been cleared."
|
|
--#SUMMARY "A warning condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 753
|
|
|
|
rpduInformationalCondition TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A RPDU informational condition has been detected.
|
|
The first variable is the serial number.
|
|
The second variable is the device name.
|
|
The third variable is the error number.
|
|
The fourth variable is the device number.
|
|
The fifth variable is the instance number.
|
|
The sixth variable is the trap text message."
|
|
--#TYPE "RPDU: Informational condition detected."
|
|
--#SUMMARY "An informational condition has been detected."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 754
|
|
|
|
rpduInformationalConditionCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsInteger, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A RPDU informational condition has been cleared.
|
|
The first variable is the serial number.
|
|
The second variable is the device name.
|
|
The third variable is the error number.
|
|
The fourth variable is the device number.
|
|
The fifth variable is the instance number.
|
|
The sixth variable is the trap text message."
|
|
--#TYPE "RPDU: Informational condition cleared."
|
|
--#SUMMARY "An informational condition has been cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 755
|
|
|
|
isxModularCoolingFanAlarm TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The device's internal cooling fans have failed.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC MDS: Cooling fan failure."
|
|
--#SUMMARY "Cooling fan failure."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 756
|
|
|
|
isxModularCoolingFanAlarmCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString02, mtrapargsString03, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The device's internal cooling fans are now functioning properly.
|
|
The first argument is the host device serial number.
|
|
The second argument is the host device name."
|
|
--#TYPE "APC MDS: Cooling fan alarm cleared."
|
|
--#SUMMARY "Cooling fan alarm cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 757
|
|
|
|
upsFirmwareUpdateStarted TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: Updating UPS firmware."
|
|
--#TYPE "APC UPS: Updating firmware"
|
|
--#SUMMARY "The UPS has started a firmware update."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 758
|
|
|
|
upsFirmwareUpdateFinished TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Finished updating UPS firmware."
|
|
--#TYPE "APC UPS: Finished firmware update"
|
|
--#SUMMARY "The UPS has finished the firmware update."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 759
|
|
|
|
upsFirmwareUpdateSucceeded TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: UPS firmware update succeeded."
|
|
--#TYPE "APC UPS: Firmware update succeeded"
|
|
--#SUMMARY "The UPS has successfully completed a firmware update."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 760
|
|
|
|
upsFirmwareUpdateFailed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: UPS firmware update failed."
|
|
--#TYPE "APC UPS: Firmware update failed"
|
|
--#SUMMARY "The UPS failed to complete a firmware update."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 761
|
|
|
|
upsHasNoValidFirmware TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: UPS has no valid firmware."
|
|
--#TYPE "APC UPS: No firmware"
|
|
--#SUMMARY "The UPS does not have a valid firmware."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 762
|
|
|
|
upsHasNoValidFirmwareCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: UPS now has a valid firmware."
|
|
--#TYPE "APC UPS: Now has valid firmware"
|
|
--#SUMMARY "The UPS now has a valid firmware."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 763
|
|
|
|
|
|
upsLocalDisplayButtonFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"WARNING: A local display button fault exists."
|
|
--#TYPE "APC UPS: A local display button fault exists."
|
|
--#SUMMARY "The UPS has detected a local display button error. The button may be stuck in the closed position."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 767
|
|
|
|
upsLocalDisplayButtonFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A local display button fault no longer exists."
|
|
--#TYPE "APC UPS: A local display button fault no longer exists."
|
|
--#SUMMARY "The UPS no longer detects a local display button error."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 768
|
|
|
|
upsNeedsFactorySetupFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: UPS needs factory setup."
|
|
--#TYPE "APC UPS: needs factory setup."
|
|
--#SUMMARY "The UPS is missing factory configuration information. The UPS needs to be set up by the factory."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 769
|
|
|
|
upsNeedsFactorySetupFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: UPS no longer needs factory setup."
|
|
--#TYPE "APC UPS: no longer needs factory setup."
|
|
--#SUMMARY "The UPS now has the required factory configuration information."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 770
|
|
|
|
upsEPOActive TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: Emergency Power Off (EPO) active."
|
|
--#TYPE "APC UPS: Emergency Power Off (EPO) active."
|
|
--#SUMMARY "The EPO contact on the UPS was activated causing the UPS to turn off."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 771
|
|
|
|
upsEPOActiveCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Emergency Power Off (EPO) now inactive."
|
|
--#TYPE "APC UPS: Emergency Power Off (EPO) now inactive."
|
|
--#SUMMARY "The EPO contact on the UPS is no longer activated. The UPS may be turned on."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 772
|
|
|
|
upsFirmwareMismatch TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: A firmware mismatch error exists."
|
|
--#TYPE "APC UPS: A firmware mismatch error exists."
|
|
--#SUMMARY "Parts of the system are running firmware versions not designed to work together. This may be due to an incomplete firmware update."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 773
|
|
|
|
upsFirmwareMismatchCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A firmware mismatch error no longer exists."
|
|
--#TYPE "APC UPS: A firmware mismatch error no longer exists."
|
|
--#SUMMARY "The firmware versions on the system are now compatible."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 774
|
|
|
|
upsOscillatorFailed TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: An oscillator error exists."
|
|
--#TYPE "APC UPS: An oscillator error exists."
|
|
--#SUMMARY "One or more system clocks no longer keeps time due to a failed oscillator. Depending on the failure, this may result in a loss of time keeping, or render parts of the system inoperable."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 775
|
|
|
|
upsOscillatorFailedCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An oscillator error no longer exists."
|
|
--#TYPE "APC UPS: An oscillator error no longer exists."
|
|
--#SUMMARY "The oscillator error no longer exists."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 776
|
|
|
|
upsOnBatteryDueToFault TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"SEVERE: The UPS is on battery due to an error.
|
|
|
|
Symmetra UPSes: Intelligence module has reported being in self-test for
|
|
too long. When this happens, the UPS is not usually in self-test, but the
|
|
batteries are draining slowly. If left uncorrected, the batteries will
|
|
become depleted and the UPS will not be able to turn on. If UPS has at
|
|
least N+1 redundancy, check power modules one by one to determine which
|
|
keeps the UPS in self-test. Once identified, replace the module."
|
|
--#TYPE "APC UPS: The UPS is on battery due to an error."
|
|
--#SUMMARY "The UPS is on battery due to an error."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 777
|
|
|
|
upsOnBatteryDueToFaultCleared TRAP-TYPE
|
|
ENTERPRISE apc
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS is no longer on battery due to an error."
|
|
--#TYPE "APC UPS: The UPS is no longer on battery due to an error."
|
|
--#SUMMARY "The UPS is no longer on battery due to an error."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 778
|
|
|
|
|
|
END
|